{"canonical":"https://sealedbidder.com/opportunities/36c25926r0053","key":"36C25926R0053","url":"https://sealedbidder.com/opportunities/36c25926r0053","title":"Z2DA--Open Market 660-26-220 - Replace Furniture, Fixtures & Equipment for IPU","solicitation_number":"36C25926R0053","notice_type":"a","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-03-06T17:00:00Z","first_posted":"2026-02-24","last_posted":"2026-09-29","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"236220","psc":"Z2DA","set_aside":"SDVOSBC","place_state":"UT","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"49011","place_county_name":"Davis County","place_city":null,"place_city_name":null,"winner":"BEXAR-ADVANCED SOLUTIONS GROUP, LLC","award_amount":"842382.00","publications":[{"notice_id":"3e90bcc864f0490895b8b1798525897d","title":"Z2DA--660-26-220 - Replace Furniture, Fixtures & Equipment for IPU for VAMC in Salt Lake City, UT","solicitation_number":"36C25926R0053","notice_type":"p","base_type":"p","posted":"2026-02-24","posted_at":"2026-02-24T15:10:28.690Z","due_at":"2026-03-06T17:00:00Z","due_date":"2026-03-06","cancelled":false,"archived":true,"archive_date":"2026-06-13","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/3e90bcc864f0490895b8b1798525897d/view","enriched":true,"history":[{"index":3,"title":"Z2DA--660-26-220 - Replace Furniture, Fixtures & Equipment for IPU for VAMC in Salt Lake City, UT","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-24T15:10:28.690Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"3e90bcc864f0490895b8b1798525897d","solicitation_number":"36C25926R0053"}]},{"notice_id":"1298f3bc045a4c1eacfcadae2a6205eb","title":"Z2DA--Open Market 660-26-220 - Replace Furniture, Fixtures & Equipment for IPU","solicitation_number":"36C25926R0053","notice_type":"a","base_type":"a","posted":"2026-09-29","posted_at":"2026-09-29T15:16:51.912Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-10-13","removed_at":null,"award_number":"36C25926C0064","awardee_name":"BEXAR-ADVANCED SOLUTIONS GROUP, LLC","amount":"842382.00","link_sam":"https://sam.gov/workspace/contract/opp/1298f3bc045a4c1eacfcadae2a6205eb/view","enriched":true,"history":[{"index":1,"title":"Z2DA--Open Market 660-26-220 - Replace Furniture, Fixtures & Equipment for IPU","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-29T15:16:51.912Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"1298f3bc045a4c1eacfcadae2a6205eb","solicitation_number":"36C25926R0053"}]},{"notice_id":"5d24d1dc10a14960a3956a0a7cbfbcad","title":"Z2DA--Open Market 660-26-220 - Replace Furniture, Fixtures & Equipment for IPU","solicitation_number":"36C25926R0053","notice_type":"a","base_type":"a","posted":"2026-09-29","posted_at":"2026-09-29T15:16:51.327Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-10-13","removed_at":null,"award_number":"36C25926C0064","awardee_name":"BEXAR-ADVANCED SOLUTIONS GROUP, LLC","amount":"842382.00","link_sam":"https://sam.gov/workspace/contract/opp/5d24d1dc10a14960a3956a0a7cbfbcad/view","enriched":true,"history":[{"index":1,"title":"Z2DA--Open Market 660-26-220 - Replace Furniture, Fixtures & Equipment for IPU","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-29T15:16:51.327Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"5d24d1dc10a14960a3956a0a7cbfbcad","solicitation_number":"36C25926R0053"}]},{"notice_id":"aa4cc50e90d3408a86372fce63689b69","title":"Z2DA--Open Market 660-26-220 - Replace Furniture, Fixtures & Equipment for IPU","solicitation_number":"36C25926R0053","notice_type":"a","base_type":"a","posted":"2026-09-29","posted_at":"2026-09-29T15:16:41.940Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-10-13","removed_at":null,"award_number":"36C25926C0064","awardee_name":"BEXAR-ADVANCED SOLUTIONS GROUP, LLC","amount":"842382.00","link_sam":"https://sam.gov/workspace/contract/opp/aa4cc50e90d3408a86372fce63689b69/view","enriched":true,"history":[{"index":1,"title":"Z2DA--Open Market 660-26-220 - Replace Furniture, Fixtures & Equipment for IPU","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-29T15:16:41.940Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"aa4cc50e90d3408a86372fce63689b69","solicitation_number":"36C25926R0053"}]},{"notice_id":"f0d0b989297342ce9fa762c200061aff","title":"Z2DA--Open Market 660-26-220 - Replace Furniture, Fixtures & Equipment for IPU","solicitation_number":"36C25926R0053","notice_type":"a","base_type":"a","posted":"2026-09-29","posted_at":"2026-09-29T15:16:37.071Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-10-13","removed_at":null,"award_number":"36C25926C0064","awardee_name":"BEXAR-ADVANCED SOLUTIONS GROUP, LLC","amount":"842382.00","link_sam":"https://sam.gov/workspace/contract/opp/f0d0b989297342ce9fa762c200061aff/view","enriched":true,"history":[{"index":1,"title":"Z2DA--Open Market 660-26-220 - Replace Furniture, Fixtures & Equipment for IPU","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-29T15:16:37.071Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"f0d0b989297342ce9fa762c200061aff","solicitation_number":"36C25926R0053"}]}],"latest_notice_id":"f0d0b989297342ce9fa762c200061aff","first_type":"p","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-02-24","posted_at":"2026-02-24T15:10:28.690Z","created_at":"2026-02-24T15:10:25.440Z","modified_at":"2026-06-14T04:00:04.913Z","response_deadline":{"raw":"2026-03-06T10:00:00-07:00","utc":"2026-03-06T17:00:00Z","date":"2026-03-06","time":"10:00:00","timezone":"America/Denver","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/3e90bcc864f0490895b8b1798525897d/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z2DA--660-26-220 - Replace Furniture, Fixtures & Equipment for IPU for VAMC in Salt Lake City, UT","agency":{"office":{"code":"36C259","name":"NETWORK CONTRACT OFFICE 19 (36C259)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"organization_id":"100176750","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-06-13","archive_type":"auto_custom"},"history":[{"index":3,"title":"Z2DA--660-26-220 - Replace Furniture, Fixtures & Equipment for IPU for VAMC in Salt Lake City, UT","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-24T15:10:28.690Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"3e90bcc864f0490895b8b1798525897d","solicitation_number":"36C25926R0053"}],"contacts":[{"name":"Blake Rowland","role":"primary","email":"blake.rowland@va.gov","phone":"303-712-5781","title":"Contract Specialist"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"3e90bcc864f0490895b8b1798525897d","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"3e90bcc864f0490895b8b1798525897d","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-12T07:42:00.890112741Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"f171b63311b92b513afef7134208c1c78533f89d36524db7c9561e3a0e48e70d","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-12T07:42:00.890112741Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"THIS IS A PRESOLICIATION NOTICE   A REQUEST FOR PROPOSAL WILL BE POSTED ON OR ABOUT MARCH 9, 2026 (i.e., estimated)\n\nSalt Lake City VA Medical Center\n(SLC VAMC)\nStatement of Work\nREPLACE FURNITURE, FIXTURES & EQUIPMENT (FF&E)\n\nProject Number: 660-26-220\nProject Title: Replace Furniture, Fixtures & Equipment (FF&E) IPU\n\nGeneral Objectives and Requirements\n\nNumber and Title of project: 660-26-220 Replace Furniture, Fixtures & Equipment (FF&E) IPU.\n\nAuthority for the project: Veterans Affairs (VA); National Contracting Office (NCO) 19.\n\nPurpose of the project: To replace all sinks, toilets, and locksets in all IPU patient rooms, to replace the grid ceiling in all patient areas, including the hallways, community rooms including the sunroom, where patients have physical access, as well as the sally port areas, with either a hard gypsum ceiling with access panels or a mental health grade ceiling panel system, see attached floor plan for locations of each of ceiling type. The door to the laundry area needs to be replaced with a door with built in wicket door (it s possible we may allow a new door to be installed to open outward, for the laundry room, but this must be approved by the COR) to eliminate barricade risk. All patient room and patient bathroom doors with hardware to receive new anti-ligature hardware and anti-ligature strike/latch assemblies.  Must provide adequate number of sizes of anti-ligature access doors to all areas above the ceiling requiring any maintenance access. Please estimate to provide around 1 access door for every 100SF of solid ceiling installed, although final locations will need to be determined once ceiling is open and access doors can be scheduled.\n\nBackground: It was determined, through The Joint Commission (TJC) Environment of Care (EOC) and Office of Inspector General (OIG) survey, that several aspects of the IPU are degraded beyond repair.\n\nScope and methodology: To replace the entire grid ceiling with a gypsum ceiling, mental health grade panels and tamper-resistant access panels, all patient-use fixtures, and all patient room doors and hardware. The project shall consist of 6 distinct construction phases. This was decided after stakeholders input to maintain access to the isolation room and emergency egress.\n\nThe C&A requirements do not apply, and a Security Accreditation Package is not required.\n\nTasks and Associated Deliverables\n\nDescription of tasks and associated deliverables: Construction tasks and deliverables shall be in accordance with this statement of work (SOW), construction specifications, and drawings.  \n\nComplete the following tasks:\nTo replace 1,090 SF of existing acoustical ceiling tile (ACT) ceiling system with a framed 5/8  gypsum drywall ceiling system, with access panels:\nAccess panels must be installed and sized appropriately where maintenance access is required (junction boxes, etc.)\nAll access panels must be tamper proof and accessible with a specialized key.\nWall repair shall be a level IV finish, where disturbed, to fully match existing material and finish.\nTo replace 2,565 SF of existing ACT ceiling system with a tamper-resistant ceiling panel system capable of a minimum sound blocking (CAC) value of 35 and sound absorption (NRC) value of 0.85. Panels shall be mechanically fastened with tamper resistant fasteners or installed with tamper resistant clips to the ceiling grid. Panels shall be accessible with a special tool and must not be openable by hand for patient safety. Panels must be sized appropriately for maintenance access (30  x 30 ). Implement manufacturers required suspension system, and HVAC diffusers and grilles. Install ceiling panel system in manner that meets manufacturer requirements. Panel color shall be approved by VA prior to ordering.\nTo replace 18 patient-use toilets with Ligature Resistant ADA Compliant Stainless-Steel Toilet for In-Wall Mounting, with powder-coated finish on the exterior of the fixture only. No paint or power-coating or any other finish on the interior basin of the fixture. Automatic flush valves are preferred. If automatic valves are not available, please supply the COR with shop drawings for a mechanical flushing toilet. \nTo replace 18 patient-use sinks with Ligature Resistant ADA Compliant Stainless-Steel Sink for in-wall mounting, with powder-coated finish on the exterior of the fixture only.  No paint or power-coating or any other finish on the interior basin of the fixture.  \nTo replace 27 (no longer replacing the isolation room door) patient room doors with inward-opening, 20-minute rated Barrier-Resistant Interior Wood Doors. The doors shall include:\nOutward-opening wicket door, as close to a 34  width x 64  height as allowable by manufacturer, centered horizontally and vertically in main door, with opening 10  from bottom of door to 10  from top of door, to include:\nBeveled Wicket Door Edge.\nLaminated glass view panel (5/16  thick, 5  width x 20  height opening), horizontally set 9  from the opening side of the wicket door, vertically set 3 6  from the bottom of the view panel to finished floor; must include integral blinds in the view panel, with operable controls, with a specialized key, located on the corridor for staff access.\nReplacement of both C-wing and D-wing door handles with a new anti-ligature handle that matches the design of the current C-wing handles. Implement quiet action to door handles, if possible, without negatively impacting the door s fire rating.\nPainted metal frame around the View Panel to match patient room door color as closely as possible.\nConcealed wicket door hinge, as supplied by Manufacturer.\nA single-sided deadbolt able to accept the housing and cylinder in use at the VHASLCHCS IPU.\nFlush-mount door pulls.\nMylar 20-minute label to be located on top of wicket door in lieu of being located on the corridor door, so that it is hidden from view and protected from tampering.\nOver the door alarms shall be removed, reinstalled, and recertified to confirm connection to the established alarm system. \nProtection Plates on the lower 10  of door, just up to the wicket door opening as close to the side and bottom edges of the door as possible.\nBeveled Replaceable Edge Profile.  \nLigature-resistant institutional privacy mortise locksets, to include:\nLigature-Resistant Strikes\nLigature-Resistant Tapered Collars compatible with the cylinders in use at the VA Salt Lake City Health Care Service IPU.\nHousing for all locks.\nFor added security, construction hard walls must be Hard-Body Impact Resistant Classification Level 1 (90f.-lbs).\n\n\nPerformance Period: 180 calendar days from NTP.  \n\nHours of work: Work shall take place during normal business hours (7:00 AM to 5:00 PM), Monday through Friday, all Federal Holidays excluded. Weekend and holiday work and work outside normal business hours may be allowed upon approval from the COR. Written notification must be given to the COR at least five working days before the weekend, holiday, or day in question. \n\nFederal Holiday: The following Federal legal holidays are observed by this facility:\nNew Year s Day\nJanuary 1\nMartin Luther King s Birthday\nThird Monday in January\nPresident s Day\nThird Monday in February\nMemorial Day\nLast Monday in May\nJuneteenth\nJune 19\nIndependence Day\nJuly 4\nLabor Day\nFirst Monday in September\nColumbus Day\nSecond Monday in November\nVeteran s Day\nNovember 11\nThanksgiving Day\nFourth Thursday in November\nChristmas Day\nDecember 25","text":"THIS IS A PRESOLICIATION NOTICE A REQUEST FOR PROPOSAL WILL BE POSTED ON OR ABOUT MARCH 9, 2026 (i.e., estimated)\n\nSalt Lake City VA Medical Center\n(SLC VAMC)\nStatement of Work\nREPLACE FURNITURE, FIXTURES & EQUIPMENT (FF&E)\n\nProject Number: 660-26-220\nProject Title: Replace Furniture, Fixtures & Equipment (FF&E) IPU\n\nGeneral Objectives and Requirements\n\nNumber and Title of project: 660-26-220 Replace Furniture, Fixtures & Equipment (FF&E) IPU.\n\nAuthority for the project: Veterans Affairs (VA); National Contracting Office (NCO) 19.\n\nPurpose of the project: To replace all sinks, toilets, and locksets in all IPU patient rooms, to replace the grid ceiling in all patient areas, including the hallways, community rooms including the sunroom, where patients have physical access, as well as the sally port areas, with either a hard gypsum ceiling with access panels or a mental health grade ceiling panel system, see attached floor plan for locations of each of ceiling type. The door to the laundry area needs to be replaced with a door with built in wicket door (it s possible we may allow a new door to be installed to open outward, for the laundry room, but this must be approved by the COR) to eliminate barricade risk. All patient room and patient bathroom doors with hardware to receive new anti-ligature hardware and anti-ligature strike/latch assemblies. Must provide adequate number of sizes of anti-ligature access doors to all areas above the ceiling requiring any maintenance access. Please estimate to provide around 1 access door for every 100SF of solid ceiling installed, although final locations will need to be determined once ceiling is open and access doors can be scheduled.\n\nBackground: It was determined, through The Joint Commission (TJC) Environment of Care (EOC) and Office of Inspector General (OIG) survey, that several aspects of the IPU are degraded beyond repair.\n\nScope and methodology: To replace the entire grid ceiling with a gypsum ceiling, mental health grade panels and tamper-resistant access panels, all patient-use fixtures, and all patient room doors and hardware. The project shall consist of 6 distinct construction phases. This was decided after stakeholders input to maintain access to the isolation room and emergency egress.\n\nThe C&A requirements do not apply, and a Security Accreditation Package is not required.\n\nTasks and Associated Deliverables\n\nDescription of tasks and associated deliverables: Construction tasks and deliverables shall be in accordance with this statement of work (SOW), construction specifications, and drawings.\n\nComplete the following tasks:\nTo replace 1,090 SF of existing acoustical ceiling tile (ACT) ceiling system with a framed 5/8 gypsum drywall ceiling system, with access panels:\nAccess panels must be installed and sized appropriately where maintenance access is required (junction boxes, etc.)\nAll access panels must be tamper proof and accessible with a specialized key.\nWall repair shall be a level IV finish, where disturbed, to fully match existing material and finish.\nTo replace 2,565 SF of existing ACT ceiling system with a tamper-resistant ceiling panel system capable of a minimum sound blocking (CAC) value of 35 and sound absorption (NRC) value of 0.85. Panels shall be mechanically fastened with tamper resistant fasteners or installed with tamper resistant clips to the ceiling grid. Panels shall be accessible with a special tool and must not be openable by hand for patient safety. Panels must be sized appropriately for maintenance access (30 x 30 ). Implement manufacturers required suspension system, and HVAC diffusers and grilles. Install ceiling panel system in manner that meets manufacturer requirements. Panel color shall be approved by VA prior to ordering.\nTo replace 18 patient-use toilets with Ligature Resistant ADA Compliant Stainless-Steel Toilet for In-Wall Mounting, with powder-coated finish on the exterior of the fixture only. No paint or power-coating or any other finish on the interior basin of the fixture. Automatic flush valves are preferred. If automatic valves are not available, please supply the COR with shop drawings for a mechanical flushing toilet.\nTo replace 18 patient-use sinks with Ligature Resistant ADA Compliant Stainless-Steel Sink for in-wall mounting, with powder-coated finish on the exterior of the fixture only. No paint or power-coating or any other finish on the interior basin of the fixture.\nTo replace 27 (no longer replacing the isolation room door) patient room doors with inward-opening, 20-minute rated Barrier-Resistant Interior Wood Doors. The doors shall include:\nOutward-opening wicket door, as close to a 34 width x 64 height as allowable by manufacturer, centered horizontally and vertically in main door, with opening 10 from bottom of door to 10 from top of door, to include:\nBeveled Wicket Door Edge.\nLaminated glass view panel (5/16 thick, 5 width x 20 height opening), horizontally set 9 from the opening side of the wicket door, vertically set 3 6 from the bottom of the view panel to finished floor; must include integral blinds in the view panel, with operable controls, with a specialized key, located on the corridor for staff access.\nReplacement of both C-wing and D-wing door handles with a new anti-ligature handle that matches the design of the current C-wing handles. Implement quiet action to door handles, if possible, without negatively impacting the door s fire rating.\nPainted metal frame around the View Panel to match patient room door color as closely as possible.\nConcealed wicket door hinge, as supplied by Manufacturer.\nA single-sided deadbolt able to accept the housing and cylinder in use at the VHASLCHCS IPU.\nFlush-mount door pulls.\nMylar 20-minute label to be located on top of wicket door in lieu of being located on the corridor door, so that it is hidden from view and protected from tampering.\nOver the door alarms shall be removed, reinstalled, and recertified to confirm connection to the established alarm system.\nProtection Plates on the lower 10 of door, just up to the wicket door opening as close to the side and bottom edges of the door as possible.\nBeveled Replaceable Edge Profile.\nLigature-resistant institutional privacy mortise locksets, to include:\nLigature-Resistant Strikes\nLigature-Resistant Tapered Collars compatible with the cylinders in use at the VA Salt Lake City Health Care Service IPU.\nHousing for all locks.\nFor added security, construction hard walls must be Hard-Body Impact Resistant Classification Level 1 (90f.-lbs).\n\nPerformance Period: 180 calendar days from NTP.\n\nHours of work: Work shall take place during normal business hours (7:00 AM to 5:00 PM), Monday through Friday, all Federal Holidays excluded. Weekend and holiday work and work outside normal business hours may be allowed upon approval from the COR. Written notification must be given to the COR at least five working days before the weekend, holiday, or day in question.\n\nFederal Holiday: The following Federal legal holidays are observed by this facility:\nNew Year s Day\nJanuary 1\nMartin Luther King s Birthday\nThird Monday in January\nPresident s Day\nThird Monday in February\nMemorial Day\nLast Monday in May\nJuneteenth\nJune 19\nIndependence Day\nJuly 4\nLabor Day\nFirst Monday in September\nColumbus Day\nSecond Monday in November\nVeteran s Day\nNovember 11\nThanksgiving Day\nFourth Thursday in November\nChristmas Day\nDecember 25","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"36C25926R0053","place_of_performance":{"zip":"84148","city":{"name":"Sat Lake City"},"state":{"code":"UT","name":"Utah"},"street":"Department of Veterans Affairs VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"Salt Lake City 500 Foothill Drive"},"product_service_code":"Z2DA"},{"award":{"date":"2026-07-21","amount":"842382.00","number":"36C25926C0064","awardee":{"raw":"BEXAR-ADVANCED SOLUTIONS GROUP, LLC KAYSVILLE 84037","uei":"HSPNN66K4HC7","cage":"4UPG2","name":"BEXAR-ADVANCED SOLUTIONS GROUP, LLC","location":{"zip":"84037","city":{"name":"KAYSVILLE"},"state":{"name":"UT"},"country":{"name":"UT"}}}},"dates":{"posted":"2026-09-29","posted_at":"2026-09-29T15:16:51.912Z","award_date":"2026-07-21","created_at":"2026-09-29T15:16:49.724Z","modified_at":"2026-09-29T15:16:51.912Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/1298f3bc045a4c1eacfcadae2a6205eb/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z2DA--Open Market 660-26-220 - Replace Furniture, Fixtures & Equipment for IPU","agency":{"office":{"code":"36C259","name":"NETWORK CONTRACT OFFICE 19 (36C259)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-10-13","archive_type":"auto_custom"},"history":[{"index":1,"title":"Z2DA--Open Market 660-26-220 - Replace Furniture, Fixtures & Equipment for IPU","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-29T15:16:51.912Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"1298f3bc045a4c1eacfcadae2a6205eb","solicitation_number":"36C25926R0053"}],"contacts":[{"name":"Blake C Rowland (CS)","role":"primary","email":"Blake.Rowland@va.gov","phone":"000-000-0000","title":"Contract Specialist"}],"base_type":{"code":"a","label":"Award Notice"},"notice_id":"1298f3bc045a4c1eacfcadae2a6205eb","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"1298f3bc045a4c1eacfcadae2a6205eb","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-30T08:45:55.846221626Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"637623f0a129b343f43488f15503f78b434fc520414d539d089fa23bfb748d0d","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-09-30T04:12:42.529040938Z"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"36C25926R0053","product_service_code":"Z2DA"},{"award":{"date":"2026-07-21","amount":"842382.00","number":"36C25926C0064","awardee":{"raw":"BEXAR-ADVANCED SOLUTIONS GROUP, LLC KAYSVILLE 84037","uei":"HSPNN66K4HC7","cage":"4UPG2","name":"BEXAR-ADVANCED SOLUTIONS GROUP, LLC","location":{"zip":"84037","city":{"name":"KAYSVILLE"},"state":{"name":"UT"},"country":{"name":"UT"}}}},"dates":{"posted":"2026-09-29","posted_at":"2026-09-29T15:16:51.327Z","award_date":"2026-07-21","created_at":"2026-09-29T15:16:50.185Z","modified_at":"2026-09-29T15:16:51.327Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/5d24d1dc10a14960a3956a0a7cbfbcad/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z2DA--Open Market 660-26-220 - Replace Furniture, Fixtures & Equipment for IPU","agency":{"office":{"code":"36C259","name":"NETWORK CONTRACT OFFICE 19 (36C259)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-10-13","archive_type":"auto_custom"},"history":[{"index":1,"title":"Z2DA--Open Market 660-26-220 - Replace Furniture, Fixtures & Equipment for IPU","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-29T15:16:51.327Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"5d24d1dc10a14960a3956a0a7cbfbcad","solicitation_number":"36C25926R0053"}],"contacts":[{"name":"Blake C Rowland (CS)","role":"primary","email":"Blake.Rowland@va.gov","phone":"000-000-0000","title":"Contract Specialist"}],"base_type":{"code":"a","label":"Award Notice"},"notice_id":"5d24d1dc10a14960a3956a0a7cbfbcad","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"5d24d1dc10a14960a3956a0a7cbfbcad","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-30T09:02:54.137702720Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"269de344361e8bbfbaf89eac4d884c04bca19af8e9f6dfefbdf77c4181001b0d","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-09-30T04:12:42.529040938Z"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"36C25926R0053","product_service_code":"Z2DA"},{"award":{"date":"2026-07-21","amount":"842382.00","number":"36C25926C0064","awardee":{"raw":"BEXAR-ADVANCED SOLUTIONS GROUP, LLC KAYSVILLE 84037","uei":"HSPNN66K4HC7","cage":"4UPG2","name":"BEXAR-ADVANCED SOLUTIONS GROUP, LLC","location":{"zip":"84037","city":{"name":"KAYSVILLE"},"state":{"name":"UT"},"country":{"name":"UT"}}}},"dates":{"posted":"2026-09-29","posted_at":"2026-09-29T15:16:41.940Z","award_date":"2026-07-21","created_at":"2026-09-29T15:16:40.703Z","modified_at":"2026-09-29T15:16:41.940Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/aa4cc50e90d3408a86372fce63689b69/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z2DA--Open Market 660-26-220 - Replace Furniture, Fixtures & Equipment for IPU","agency":{"office":{"code":"36C259","name":"NETWORK CONTRACT OFFICE 19 (36C259)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-10-13","archive_type":"auto_custom"},"history":[{"index":1,"title":"Z2DA--Open Market 660-26-220 - Replace Furniture, Fixtures & Equipment for IPU","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-29T15:16:41.940Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"aa4cc50e90d3408a86372fce63689b69","solicitation_number":"36C25926R0053"}],"contacts":[{"name":"Blake C Rowland (CS)","role":"primary","email":"Blake.Rowland@va.gov","phone":"000-000-0000","title":"Contract Specialist"}],"base_type":{"code":"a","label":"Award Notice"},"notice_id":"aa4cc50e90d3408a86372fce63689b69","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"aa4cc50e90d3408a86372fce63689b69","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-30T09:09:13.233473730Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"ff9bf62359a2b77babf24e1b6a60f9ac9c19ae5338283ae716c36e88a850f0c0","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-09-30T04:12:42.529040938Z"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"36C25926R0053","product_service_code":"Z2DA"},{"award":{"date":"2026-07-21","amount":"842382.00","number":"36C25926C0064","awardee":{"raw":"BEXAR-ADVANCED SOLUTIONS GROUP, LLC KAYSVILLE 84037","uei":"HSPNN66K4HC7","cage":"4UPG2","name":"BEXAR-ADVANCED SOLUTIONS GROUP, LLC","location":{"zip":"84037","city":{"name":"KAYSVILLE"},"state":{"name":"UT"},"country":{"name":"UT"}}}},"dates":{"posted":"2026-09-29","posted_at":"2026-09-29T15:16:37.071Z","award_date":"2026-07-21","created_at":"2026-09-29T15:16:34.900Z","modified_at":"2026-09-29T15:16:37.071Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/f0d0b989297342ce9fa762c200061aff/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z2DA--Open Market 660-26-220 - Replace Furniture, Fixtures & Equipment for IPU","agency":{"office":{"code":"36C259","name":"NETWORK CONTRACT OFFICE 19 (36C259)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-10-13","archive_type":"auto_custom"},"history":[{"index":1,"title":"Z2DA--Open Market 660-26-220 - Replace Furniture, Fixtures & Equipment for IPU","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-29T15:16:37.071Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"f0d0b989297342ce9fa762c200061aff","solicitation_number":"36C25926R0053"}],"contacts":[{"name":"Blake C Rowland (CS)","role":"primary","email":"Blake.Rowland@va.gov","phone":"000-000-0000","title":"Contract Specialist"}],"base_type":{"code":"a","label":"Award Notice"},"notice_id":"f0d0b989297342ce9fa762c200061aff","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"f0d0b989297342ce9fa762c200061aff","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-30T09:23:37.514950329Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"d6efca076d16fcd29452cbdd73f52b044701fb058164f46e4a1c984711601e78","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-09-30T04:12:42.529040938Z"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"36C25926R0053","product_service_code":"Z2DA"}],"due_at":"2026-03-06T17:00:00Z","due_date":"2026-03-06","closes_at":"2026-03-06T17:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","state":"UT","county":"49011","county_name":"Davis County","city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"HSPNN66K4HC7","amount":"842382.00","linked_awards":5,"cancelled":false,"archived":true,"updated_at":"2026-10-14T04:54:08.570351Z","principal_notice_id":"3e90bcc864f0490895b8b1798525897d","description":{"text":"THIS IS A PRESOLICIATION NOTICE A REQUEST FOR PROPOSAL WILL BE POSTED ON OR ABOUT MARCH 9, 2026 (i.e., estimated)\n\nSalt Lake City VA Medical Center\n(SLC VAMC)\nStatement of Work\nREPLACE FURNITURE, FIXTURES & EQUIPMENT (FF&E)\n\nProject Number: 660-26-220\nProject Title: Replace Furniture, Fixtures & Equipment (FF&E) IPU\n\nGeneral Objectives and Requirements\n\nNumber and Title of project: 660-26-220 Replace Furniture, Fixtures & Equipment (FF&E) IPU.\n\nAuthority for the project: Veterans Affairs (VA); National Contracting Office (NCO) 19.\n\nPurpose of the project: To replace all sinks, toilets, and locksets in all IPU patient rooms, to replace the grid ceiling in all patient areas, including the hallways, community rooms including the sunroom, where patients have physical access, as well as the sally port areas, with either a hard gypsum ceiling with access panels or a mental health grade ceiling panel system, see attached floor plan for locations of each of ceiling type. The door to the laundry area needs to be replaced with a door with built in wicket door (it s possible we may allow a new door to be installed to open outward, for the laundry room, but this must be approved by the COR) to eliminate barricade risk. All patient room and patient bathroom doors with hardware to receive new anti-ligature hardware and anti-ligature strike/latch assemblies. Must provide adequate number of sizes of anti-ligature access doors to all areas above the ceiling requiring any maintenance access. Please estimate to provide around 1 access door for every 100SF of solid ceiling installed, although final locations will need to be determined once ceiling is open and access doors can be scheduled.\n\nBackground: It was determined, through The Joint Commission (TJC) Environment of Care (EOC) and Office of Inspector General (OIG) survey, that several aspects of the IPU are degraded beyond repair.\n\nScope and methodology: To replace the entire grid ceiling with a gypsum ceiling, mental health grade panels and tamper-resistant access panels, all patient-use fixtures, and all patient room doors and hardware. The project shall consist of 6 distinct construction phases. This was decided after stakeholders input to maintain access to the isolation room and emergency egress.\n\nThe C&A requirements do not apply, and a Security Accreditation Package is not required.\n\nTasks and Associated Deliverables\n\nDescription of tasks and associated deliverables: Construction tasks and deliverables shall be in accordance with this statement of work (SOW), construction specifications, and drawings.\n\nComplete the following tasks:\nTo replace 1,090 SF of existing acoustical ceiling tile (ACT) ceiling system with a framed 5/8 gypsum drywall ceiling system, with access panels:\nAccess panels must be installed and sized appropriately where maintenance access is required (junction boxes, etc.)\nAll access panels must be tamper proof and accessible with a specialized key.\nWall repair shall be a level IV finish, where disturbed, to fully match existing material and finish.\nTo replace 2,565 SF of existing ACT ceiling system with a tamper-resistant ceiling panel system capable of a minimum sound blocking (CAC) value of 35 and sound absorption (NRC) value of 0.85. Panels shall be mechanically fastened with tamper resistant fasteners or installed with tamper resistant clips to the ceiling grid. Panels shall be accessible with a special tool and must not be openable by hand for patient safety. Panels must be sized appropriately for maintenance access (30 x 30 ). Implement manufacturers required suspension system, and HVAC diffusers and grilles. Install ceiling panel system in manner that meets manufacturer requirements. Panel color shall be approved by VA prior to ordering.\nTo replace 18 patient-use toilets with Ligature Resistant ADA Compliant Stainless-Steel Toilet for In-Wall Mounting, with powder-coated finish on the exterior of the fixture only. No paint or power-coating or any other finish on the interior basin of the fixture. Automatic flush valves are preferred. If automatic valves are not available, please supply the COR with shop drawings for a mechanical flushing toilet.\nTo replace 18 patient-use sinks with Ligature Resistant ADA Compliant Stainless-Steel Sink for in-wall mounting, with powder-coated finish on the exterior of the fixture only. No paint or power-coating or any other finish on the interior basin of the fixture.\nTo replace 27 (no longer replacing the isolation room door) patient room doors with inward-opening, 20-minute rated Barrier-Resistant Interior Wood Doors. The doors shall include:\nOutward-opening wicket door, as close to a 34 width x 64 height as allowable by manufacturer, centered horizontally and vertically in main door, with opening 10 from bottom of door to 10 from top of door, to include:\nBeveled Wicket Door Edge.\nLaminated glass view panel (5/16 thick, 5 width x 20 height opening), horizontally set 9 from the opening side of the wicket door, vertically set 3 6 from the bottom of the view panel to finished floor; must include integral blinds in the view panel, with operable controls, with a specialized key, located on the corridor for staff access.\nReplacement of both C-wing and D-wing door handles with a new anti-ligature handle that matches the design of the current C-wing handles. Implement quiet action to door handles, if possible, without negatively impacting the door s fire rating.\nPainted metal frame around the View Panel to match patient room door color as closely as possible.\nConcealed wicket door hinge, as supplied by Manufacturer.\nA single-sided deadbolt able to accept the housing and cylinder in use at the VHASLCHCS IPU.\nFlush-mount door pulls.\nMylar 20-minute label to be located on top of wicket door in lieu of being located on the corridor door, so that it is hidden from view and protected from tampering.\nOver the door alarms shall be removed, reinstalled, and recertified to confirm connection to the established alarm system.\nProtection Plates on the lower 10 of door, just up to the wicket door opening as close to the side and bottom edges of the door as possible.\nBeveled Replaceable Edge Profile.\nLigature-resistant institutional privacy mortise locksets, to include:\nLigature-Resistant Strikes\nLigature-Resistant Tapered Collars compatible with the cylinders in use at the VA Salt Lake City Health Care Service IPU.\nHousing for all locks.\nFor added security, construction hard walls must be Hard-Body Impact Resistant Classification Level 1 (90f.-lbs).\n\nPerformance Period: 180 calendar days from NTP.\n\nHours of work: Work shall take place during normal business hours (7:00 AM to 5:00 PM), Monday through Friday, all Federal Holidays excluded. Weekend and holiday work and work outside normal business hours may be allowed upon approval from the COR. Written notification must be given to the COR at least five working days before the weekend, holiday, or day in question.\n\nFederal Holiday: The following Federal legal holidays are observed by this facility:\nNew Year s Day\nJanuary 1\nMartin Luther King s Birthday\nThird Monday in January\nPresident s Day\nThird Monday in February\nMemorial Day\nLast Monday in May\nJuneteenth\nJune 19\nIndependence Day\nJuly 4\nLabor Day\nFirst Monday in September\nColumbus Day\nSecond Monday in November\nVeteran s Day\nNovember 11\nThanksgiving Day\nFourth Thursday in November\nChristmas Day\nDecember 25","html":"THIS IS A PRESOLICIATION NOTICE   A REQUEST FOR PROPOSAL WILL BE POSTED ON OR ABOUT MARCH 9, 2026 (i.e., estimated)\n\nSalt Lake City VA Medical Center\n(SLC VAMC)\nStatement of Work\nREPLACE FURNITURE, FIXTURES & EQUIPMENT (FF&E)\n\nProject Number: 660-26-220\nProject Title: Replace Furniture, Fixtures & Equipment (FF&E) IPU\n\nGeneral Objectives and Requirements\n\nNumber and Title of project: 660-26-220 Replace Furniture, Fixtures & Equipment (FF&E) IPU.\n\nAuthority for the project: Veterans Affairs (VA); National Contracting Office (NCO) 19.\n\nPurpose of the project: To replace all sinks, toilets, and locksets in all IPU patient rooms, to replace the grid ceiling in all patient areas, including the hallways, community rooms including the sunroom, where patients have physical access, as well as the sally port areas, with either a hard gypsum ceiling with access panels or a mental health grade ceiling panel system, see attached floor plan for locations of each of ceiling type. The door to the laundry area needs to be replaced with a door with built in wicket door (it s possible we may allow a new door to be installed to open outward, for the laundry room, but this must be approved by the COR) to eliminate barricade risk. All patient room and patient bathroom doors with hardware to receive new anti-ligature hardware and anti-ligature strike/latch assemblies.  Must provide adequate number of sizes of anti-ligature access doors to all areas above the ceiling requiring any maintenance access. Please estimate to provide around 1 access door for every 100SF of solid ceiling installed, although final locations will need to be determined once ceiling is open and access doors can be scheduled.\n\nBackground: It was determined, through The Joint Commission (TJC) Environment of Care (EOC) and Office of Inspector General (OIG) survey, that several aspects of the IPU are degraded beyond repair.\n\nScope and methodology: To replace the entire grid ceiling with a gypsum ceiling, mental health grade panels and tamper-resistant access panels, all patient-use fixtures, and all patient room doors and hardware. The project shall consist of 6 distinct construction phases. This was decided after stakeholders input to maintain access to the isolation room and emergency egress.\n\nThe C&A requirements do not apply, and a Security Accreditation Package is not required.\n\nTasks and Associated Deliverables\n\nDescription of tasks and associated deliverables: Construction tasks and deliverables shall be in accordance with this statement of work (SOW), construction specifications, and drawings.  \n\nComplete the following tasks:\nTo replace 1,090 SF of existing acoustical ceiling tile (ACT) ceiling system with a framed 5/8  gypsum drywall ceiling system, with access panels:\nAccess panels must be installed and sized appropriately where maintenance access is required (junction boxes, etc.)\nAll access panels must be tamper proof and accessible with a specialized key.\nWall repair shall be a level IV finish, where disturbed, to fully match existing material and finish.\nTo replace 2,565 SF of existing ACT ceiling system with a tamper-resistant ceiling panel system capable of a minimum sound blocking (CAC) value of 35 and sound absorption (NRC) value of 0.85. Panels shall be mechanically fastened with tamper resistant fasteners or installed with tamper resistant clips to the ceiling grid. Panels shall be accessible with a special tool and must not be openable by hand for patient safety. Panels must be sized appropriately for maintenance access (30  x 30 ). Implement manufacturers required suspension system, and HVAC diffusers and grilles. Install ceiling panel system in manner that meets manufacturer requirements. Panel color shall be approved by VA prior to ordering.\nTo replace 18 patient-use toilets with Ligature Resistant ADA Compliant Stainless-Steel Toilet for In-Wall Mounting, with powder-coated finish on the exterior of the fixture only. No paint or power-coating or any other finish on the interior basin of the fixture. Automatic flush valves are preferred. If automatic valves are not available, please supply the COR with shop drawings for a mechanical flushing toilet. \nTo replace 18 patient-use sinks with Ligature Resistant ADA Compliant Stainless-Steel Sink for in-wall mounting, with powder-coated finish on the exterior of the fixture only.  No paint or power-coating or any other finish on the interior basin of the fixture.  \nTo replace 27 (no longer replacing the isolation room door) patient room doors with inward-opening, 20-minute rated Barrier-Resistant Interior Wood Doors. The doors shall include:\nOutward-opening wicket door, as close to a 34  width x 64  height as allowable by manufacturer, centered horizontally and vertically in main door, with opening 10  from bottom of door to 10  from top of door, to include:\nBeveled Wicket Door Edge.\nLaminated glass view panel (5/16  thick, 5  width x 20  height opening), horizontally set 9  from the opening side of the wicket door, vertically set 3 6  from the bottom of the view panel to finished floor; must include integral blinds in the view panel, with operable controls, with a specialized key, located on the corridor for staff access.\nReplacement of both C-wing and D-wing door handles with a new anti-ligature handle that matches the design of the current C-wing handles. Implement quiet action to door handles, if possible, without negatively impacting the door s fire rating.\nPainted metal frame around the View Panel to match patient room door color as closely as possible.\nConcealed wicket door hinge, as supplied by Manufacturer.\nA single-sided deadbolt able to accept the housing and cylinder in use at the VHASLCHCS IPU.\nFlush-mount door pulls.\nMylar 20-minute label to be located on top of wicket door in lieu of being located on the corridor door, so that it is hidden from view and protected from tampering.\nOver the door alarms shall be removed, reinstalled, and recertified to confirm connection to the established alarm system. \nProtection Plates on the lower 10  of door, just up to the wicket door opening as close to the side and bottom edges of the door as possible.\nBeveled Replaceable Edge Profile.  \nLigature-resistant institutional privacy mortise locksets, to include:\nLigature-Resistant Strikes\nLigature-Resistant Tapered Collars compatible with the cylinders in use at the VA Salt Lake City Health Care Service IPU.\nHousing for all locks.\nFor added security, construction hard walls must be Hard-Body Impact Resistant Classification Level 1 (90f.-lbs).\n\n\nPerformance Period: 180 calendar days from NTP.  \n\nHours of work: Work shall take place during normal business hours (7:00 AM to 5:00 PM), Monday through Friday, all Federal Holidays excluded. Weekend and holiday work and work outside normal business hours may be allowed upon approval from the COR. Written notification must be given to the COR at least five working days before the weekend, holiday, or day in question. \n\nFederal Holiday: The following Federal legal holidays are observed by this facility:\nNew Year s Day\nJanuary 1\nMartin Luther King s Birthday\nThird Monday in January\nPresident s Day\nThird Monday in February\nMemorial Day\nLast Monday in May\nJuneteenth\nJune 19\nIndependence Day\nJuly 4\nLabor Day\nFirst Monday in September\nColumbus Day\nSecond Monday in November\nVeteran s Day\nNovember 11\nThanksgiving Day\nFourth Thursday in November\nChristmas Day\nDecember 25","origin":"detail"},"contacts":[{"name":"Blake C Rowland (CS)","role":"primary","email":"Blake.Rowland@va.gov","phone":"000-000-0000","title":"Contract Specialist"}],"place_of_performance":{"zip":"84148","city":{"name":"Sat Lake City"},"state":{"code":"UT","name":"Utah"},"street":"Department of Veterans Affairs VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"Salt Lake City 500 Foothill Drive"},"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"naics_codes":["236220"],"award":{"awardee":{}},"attachments":[{"resource_id":"0ab576f4cc2340ad9073b9790780c244","name":"va.gov","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2026-02-24T15:10:28.690Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov","mirrored":false},{"resource_id":"0f360496d05142baba8e0fafb92446cc","name":"36C25926C0064_1.docx","kind":"file","mime_type":".docx","size_bytes":13654,"posted_at":"2026-09-29T15:16:37.071Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/0f360496d05142baba8e0fafb92446cc/download","mirrored":false},{"resource_id":"4f6bbde486814a638072b3c32790f712","name":"36C25926C0064_1.docx","kind":"file","mime_type":".docx","size_bytes":13654,"posted_at":"2026-09-29T15:16:41.940Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/4f6bbde486814a638072b3c32790f712/download","mirrored":false},{"resource_id":"a3e432cf91354085a4ba83358923638f","name":"36C25926C0064_1.docx","kind":"file","mime_type":".docx","size_bytes":13654,"posted_at":"2026-09-29T15:16:51.327Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/a3e432cf91354085a4ba83358923638f/download","mirrored":false},{"resource_id":"d4dc3b5261134fe999befafd225b38c7","name":"36C25926C0064_1.docx","kind":"file","mime_type":".docx","size_bytes":13654,"posted_at":"2026-09-29T15:16:51.912Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/d4dc3b5261134fe999befafd225b38c7/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C25926C0064_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C25926C0064_3600_-NONE-_-NONE-/","piid":"36C25926C0064","parent_piid":null,"award_type":"DEFINITIVE CONTRACT","vendor_key":"HSPNN66K4HC7","recipient_name":"BEXAR-ADVANCED SOLUTIONS GROUP, LLC","recipient_uei":"HSPNN66K4HC7","recipient_cage":"4UPG2","recipient_city":"KAYSVILLE","recipient_state":"UT","sub_name":"Department of Veterans Affairs","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","office_key":"o-36C259","first_action_date":"2026-07-21","last_action_date":"2026-07-21","actions":1,"obligated":"842382.00","current_total_value":"842382.00","potential_total_value":"842382.00","naics":"236220","psc":"Z2DA","extent_competed":"COMPETED UNDER SAP","set_aside":"SERVICE DISABLED VETERAN OWNED SMALL BUSINESS SET-ASIDE","offers_received":3,"description":"REPLACE FURNITURE, FIXTURES & EQUIPMENT FOR IPU","method":"solicitation","confidence":"high","evidence":["solicitation number 36C25926R0053 equals the FPDS solicitation identifier","same awarding office 36C259"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C25927Q0058","latest_notice_id":"f7ba8da853564af6a36ca00b9a898459","title":"Q301--NEW | Automated Blood Bank Solid Phase Analyzer and Associated Reagents/Consumables","solicitation_number":"36C25927Q0058","notice_type":"r","first_type":"r","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-25T22:30:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T22:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"334516","psc":"Q301","set_aside":null,"state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"36C25927Q0048","latest_notice_id":"c63e9c1e32f4475caa79c878ba87ca2f","title":"Radiant Heating Panel Replacement","solicitation_number":"36C25927Q0048","notice_type":"k","first_type":"k","first_posted":"2026-11-04","last_posted":"2026-11-23","notices":3,"due_at":"2026-11-27T19:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"238220","psc":"J045","set_aside":"SBA","state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C25927Q0061","latest_notice_id":"2844a59e27da407db5c5aac404bd35d7","title":"AI tool for Medication Reconciliation and Clinical Review","solicitation_number":"36C25927Q0061","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"541519","psc":"DA10","set_aside":null,"state":"CO","county":"08077","county_name":"Mesa County","city":"0831660","city_name":"Grand Junction","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C25927Q0060","latest_notice_id":"dab1ae13fa4543da8629e3ba28875296","title":"J023-- Transmission Repair/Replacement x2","solicitation_number":"36C25927Q0060","notice_type":"k","first_type":"k","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-12-04T17:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"811111","psc":"J023","set_aside":"SBA","state":"UT","county":"49035","county_name":"Salt Lake County","city":"4967000","city_name":"Salt Lake City","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C25927Q0063","latest_notice_id":"3aec52f34d1346bcb89262decf41e0e9","title":"J045--Annual Boiler Maintenance RMR VAMC","solicitation_number":"36C25927Q0063","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-04T21:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"238220","psc":"J045","set_aside":null,"state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":"sam_zip","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open":[{"key":"N6945027RP233","latest_notice_id":"2c675cdda8ef42a2842c5cbcb3d50727","title":"P233 AIR TRAFFIC CONTROL TOWER AND FLIGHT SIMULATOR TRAINING FACILITY","solicitation_number":"N6945027RP233","notice_type":"p","first_type":"r","first_posted":"2026-10-27","last_posted":"2026-11-10","notices":3,"due_at":"2026-11-25T16:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N69450","office_name":"NAVFACSYSCOM SOUTHEAST","naics":"236220","psc":"Y1BA","set_aside":null,"state":"MS","county":"28047","county_name":"Harrison County","city":"2806220","city_name":"Biloxi","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Keesler Air Force Base","site_key":"keesler-air-force-base-ms","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"36C26027R00020006","latest_notice_id":"299fab9bad854b0786fcc742e3f934d5","title":"Amendment 0006 to Provide Official RFI Responses, Update Solicitation Documents, Extend Proposal Due Date, & other Official Information","solicitation_number":"36C26027R0002-0006","notice_type":"o","first_type":"o","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":"2026-11-25T17:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"ID","county":"16001","county_name":"Ada County","city":"1608830","city_name":"Boise City","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"N4008527R0047","latest_notice_id":"210d9a8ca71f45e3ba10457201d1f3d9","title":"P758 Machinery Control Development Center, Philadelphia Navy Yard, PA","solicitation_number":"N4008527R0047","notice_type":"r","first_type":"r","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N40085","office_name":"NAVFACSYSCOM MID-ATLANTIC","naics":"236220","psc":"Y1JB","set_aside":null,"state":"PA","county":"42101","county_name":"Philadelphia County","city":"4260000","city_name":"Philadelphia","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"}],"similar_open_total":194,"indexable":false}