{"canonical":"https://sealedbidder.com/opportunities/36c25926q0526","key":"36C25926Q0526","url":"https://sealedbidder.com/opportunities/36c25926q0526","title":"6636--Research Anaerobic Chamber Purchase for Rocky Mountain Regional VA Regional Medical Center (RMRVAMC)","solicitation_number":"36C25926Q0526","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-06-16T22:00:00Z","first_posted":"2026-06-09","last_posted":"2026-06-09","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"334516","psc":"6636","set_aside":null,"place_state":"CO","place_scope":"nationwide","site":null,"place_state_source":"sam_street","place_evidence":"DEPARTMENT OF VETERANS AFFAIRS ROCKY MOUNTAIN VA MEDICAL CENTER 1700 N WHEELING ST. AURORA, CO 80045","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"e4815f8e559e49a5990d0f7854ac7c8a","title":"6636--Research Anaerobic Chamber Purchase for Rocky Mountain Regional VA Regional Medical Center (RMRVAMC)","solicitation_number":"36C25926Q0526","notice_type":"r","base_type":"r","posted":"2026-06-09","posted_at":"2026-06-09T15:05:08.362Z","due_at":"2026-06-16T22:00:00Z","due_date":"2026-06-16","cancelled":false,"archived":true,"archive_date":"2026-07-16","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/e4815f8e559e49a5990d0f7854ac7c8a/view","enriched":true,"history":[{"index":3,"title":"6636--Research Anaerobic Chamber Purchase for Rocky Mountain Regional VA Regional Medical Center (RMRVAMC)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-09T15:05:08.362Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"e4815f8e559e49a5990d0f7854ac7c8a","solicitation_number":"36C25926Q0526"}]}],"latest_notice_id":"e4815f8e559e49a5990d0f7854ac7c8a","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-06-09","posted_at":"2026-06-09T15:05:08.362Z","created_at":"2026-06-09T15:05:06.063Z","modified_at":"2026-07-17T03:55:46.287Z","response_deadline":{"raw":"2026-06-16T16:00:00-06:00","utc":"2026-06-16T22:00:00Z","date":"2026-06-16","time":"16:00:00","timezone":"America/Denver","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/e4815f8e559e49a5990d0f7854ac7c8a/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"6636--Research Anaerobic Chamber Purchase for Rocky Mountain Regional VA Regional Medical Center (RMRVAMC)","agency":{"office":{"code":"36C259","name":"NETWORK CONTRACT OFFICE 19 (36C259)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"organization_id":"100176750","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-07-16","archive_type":"auto_custom"},"history":[{"index":3,"title":"6636--Research Anaerobic Chamber Purchase for Rocky Mountain Regional VA Regional Medical Center (RMRVAMC)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-09T15:05:08.362Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"e4815f8e559e49a5990d0f7854ac7c8a","solicitation_number":"36C25926Q0526"}],"contacts":[{"name":"Devin Reichert","role":"primary","email":"Devin.Reichert@va.gov","phone":"303-712-5709","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"e4815f8e559e49a5990d0f7854ac7c8a","lineage_id":"e4815f8e559e49a5990d0f7854ac7c8a","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-02T13:35:12.138799851Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"21dfe45d9882cd3a9356cfbafebaff8cd19d3718badaaf3642c759781344e87f","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-02T13:35:12.138799851Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"Sources Sought Notice - Research Anaerobic Chamber Purchase for Rocky Mountain Regional VA Regional Medical Center (RMRVAMC)\nDisclaimer:\nThis Request for Information (RFI) is issued solely for market research information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are NOT offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\n\nInformation Requested from Industry:\n\nIn response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List.\n\nResponses to market research table questionnaire shall be submitted. If this information is not provided, then it will be assumed the entire requirement cannot be met.\n\nDepartment of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for Research Anaerobic Chamber Purchase for Rocky Mountain VA Medical Center. This Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided. \n\nResearch Anaerobic Chamber Purchase   Qty 1. The offer must meet the following salient characteristics:\nDescription\nUnit\nQty\nAnaerobic Chamber \nEA\n1\n\n\n\nSaliant features that are minimum technically required:\nElectrical will be standard 120V plug\nInterior Dimensions (equal or greater to): 55  x  31  x 40  (width x depth x height).  Depth max is 34 \nInterior volume (equal or greater to): 210 liters\nAirlock dimensions (equal or greater to): 12  x 14  x 11  inches (width x depth x height) to accommodate our sample containers\nActivated Carbon/O2 palladium cartridge scrubber\nSide access panel\nLow gas supply alarm and leak detection alarm\nEstablish <10ppm O2 in less than 1 hour to accommodate sporadic specimen delivery and need to process within 2 hrs. \nPurge cycle of 90 seconds\nSet up for gloveless sleeves or optional cuff for direct hand access\nGas tank floor restraint \nPressurized gas regulators and gas tank fittings.\nSufficient supplies and catalyst for one year of operation.\nIf the unit requires an oven system for regeneration of catalyst, that should be included with 120V plug.  Max depth is 34 .\nSystem must come with a one year warranty\n\nDelivery:\nDepartment of Veterans Affairs\nRocky Mountain Regional VA Medical Center\n1700 N. Wheeling Street\nAurora, CO, 80045\n       \nIn response to this announcement, please provide the information requested below requested in this market research table questionnaire. If this information is not provided, then it will be assumed the entire requirement cannot be met: \nNAICS Code: \nCompany Name:\nAddress:\nUEI (Unique Entity ID) Number:\nContact Name:\nPhone No.:\nEmail:\nBusiness Size Information - Select all that applies:\nSmall Business\nEmerging Small Business\nSmall Disadvantaged Business\nCertified under Section 8(a) of the Small Business Act\nHUBZone\nWoman Owned\nCertified Service-Disabled Veteran Owned Small\nVeteran Owned Small Business\nLarge Business\nFSS/GSA Contract Holder:\nYes                     No    \nFSS/GSA Contract Number:\n\nEffective Date/ Expiration Date:\n\nProposed solution is listed and available on the above FSS/GSA Contract:\nYes                     No    \nPricing Model\nPlease Indicate Availability Below: (Yes / No / NA)\nAll on FSS\nOpen Market only\nMix of FSS & Open Market\nFirm-Fixed Price\n\n\n\nFederal Acquisition Regulation (FAR) Market Rearch Questions:\n\n\n\nBuy American Act RFO 52.225-1 and RFO 52.225-2 Buy American Certificate   What percentage of the proposed product (including leases and rentals) is a:\n\n\n\nDomestic end product? _____________ (%)\n\n\n\nForeign end product? _______________ (%) Country of Origin:\n\n\n\nQuestions for Small Businesses ONLY:\n\n\n\nIf subcontracting, what added value do you offer (RFO 52.215-23): \n\n\n\nNonmanufacturer Rule (RFO 52.219-33):\nDoes your company manufacturer these proposed items? [Â  ] yes [Â  ] no\nDoes your company exceed 500 employees?  [Â  ] yes [Â  ] no   If yes, list # of employees: _________\nDoes your company primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied?  [Â  ] yes [Â  ] no\nDoes your company take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice?  [Â  ] yes [Â  ] no\nDoes your company supply the end item of a small business manufacturer, processor or producer made in the United States, or obtains a waiver of such requirement pursuant to paragraph (b)(5) CFR 121.406. [Â  ] yes [Â  ] no  If yes, what is the manufacturer s name? ________________ \n\n\nResponse Instructions:\nDo not provide more than 8 pages, including cover letter page.\nSubmit your response via email to devin.reichert@va.gov \nSubmit your response NLT 4:00 (MST) on Tuesday, June 16, 2026;\nMark your response as  Proprietary Information  if the information is considered business sensitive.\nVA has identified the appropriate North American Industry Classification System (NAICS) Code as 334516   Analytical Laboratory Instrument Manufacturing with a Small Business size of 1000 Employees.  Please identify and explain any NAICS codes your company believes would better represent the predominant work included in the attached Statement of Work draft / Salient Characteristics List.\n\n(End of Document)","text":"Sources Sought Notice - Research Anaerobic Chamber Purchase for Rocky Mountain Regional VA Regional Medical Center (RMRVAMC)\nDisclaimer:\nThis Request for Information (RFI) is issued solely for market research information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are NOT offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\n\nInformation Requested from Industry:\n\nIn response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List.\n\nResponses to market research table questionnaire shall be submitted. If this information is not provided, then it will be assumed the entire requirement cannot be met.\n\nDepartment of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for Research Anaerobic Chamber Purchase for Rocky Mountain VA Medical Center. This Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided.\n\nResearch Anaerobic Chamber Purchase Qty 1. The offer must meet the following salient characteristics:\nDescription\nUnit\nQty\nAnaerobic Chamber\nEA\n1\n\nSaliant features that are minimum technically required:\nElectrical will be standard 120V plug\nInterior Dimensions (equal or greater to): 55 x 31 x 40 (width x depth x height). Depth max is 34\nInterior volume (equal or greater to): 210 liters\nAirlock dimensions (equal or greater to): 12 x 14 x 11 inches (width x depth x height) to accommodate our sample containers\nActivated Carbon/O2 palladium cartridge scrubber\nSide access panel\nLow gas supply alarm and leak detection alarm\nEstablish <10ppm O2 in less than 1 hour to accommodate sporadic specimen delivery and need to process within 2 hrs.\nPurge cycle of 90 seconds\nSet up for gloveless sleeves or optional cuff for direct hand access\nGas tank floor restraint\nPressurized gas regulators and gas tank fittings.\nSufficient supplies and catalyst for one year of operation.\nIf the unit requires an oven system for regeneration of catalyst, that should be included with 120V plug. Max depth is 34 .\nSystem must come with a one year warranty\n\nDelivery:\nDepartment of Veterans Affairs\nRocky Mountain Regional VA Medical Center\n1700 N. Wheeling Street\nAurora, CO, 80045\n\nIn response to this announcement, please provide the information requested below requested in this market research table questionnaire. If this information is not provided, then it will be assumed the entire requirement cannot be met:\nNAICS Code:\nCompany Name:\nAddress:\nUEI (Unique Entity ID) Number:\nContact Name:\nPhone No.:\nEmail:\nBusiness Size Information - Select all that applies:\nSmall Business\nEmerging Small Business\nSmall Disadvantaged Business\nCertified under Section 8(a) of the Small Business Act\nHUBZone\nWoman Owned\nCertified Service-Disabled Veteran Owned Small\nVeteran Owned Small Business\nLarge Business\nFSS/GSA Contract Holder:\nYes No\nFSS/GSA Contract Number:\n\nEffective Date/ Expiration Date:\n\nProposed solution is listed and available on the above FSS/GSA Contract:\nYes No\nPricing Model\nPlease Indicate Availability Below: (Yes / No / NA)\nAll on FSS\nOpen Market only\nMix of FSS & Open Market\nFirm-Fixed Price\n\nFederal Acquisition Regulation (FAR) Market Rearch Questions:\n\nBuy American Act RFO 52.225-1 and RFO 52.225-2 Buy American Certificate What percentage of the proposed product (including leases and rentals) is a:\n\nDomestic end product? _____________ (%)\n\nForeign end product? _______________ (%) Country of Origin:\n\nQuestions for Small Businesses ONLY:\n\nIf subcontracting, what added value do you offer (RFO 52.215-23):\n\nNonmanufacturer Rule (RFO 52.219-33):\nDoes your company manufacturer these proposed items? [Â ] yes [Â ] no\nDoes your company exceed 500 employees? [Â ] yes [Â ] no If yes, list # of employees: _________\nDoes your company primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied? [Â ] yes [Â ] no\nDoes your company take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? [Â ] yes [Â ] no\nDoes your company supply the end item of a small business manufacturer, processor or producer made in the United States, or obtains a waiver of such requirement pursuant to paragraph (b)(5) CFR 121.406. [Â ] yes [Â ] no If yes, what is the manufacturer s name? ________________\n\nResponse Instructions:\nDo not provide more than 8 pages, including cover letter page.\nSubmit your response via email to devin.reichert@va.gov\nSubmit your response NLT 4:00 (MST) on Tuesday, June 16, 2026;\nMark your response as Proprietary Information if the information is considered business sensitive.\nVA has identified the appropriate North American Industry Classification System (NAICS) Code as 334516 Analytical Laboratory Instrument Manufacturing with a Small Business size of 1000 Employees. Please identify and explain any NAICS codes your company believes would better represent the predominant work included in the attached Statement of Work draft / Salient Characteristics List.\n\n(End of Document)","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25926Q0526","place_of_performance":{"street":"Department of Veterans Affairs Rocky Mountain VA Medical Center","street2":"1700 N Wheeling St. Aurora, CO 80045"},"product_service_code":"6636"}],"due_at":"2026-06-16T22:00:00Z","due_date":"2026-06-16","closes_at":"2026-06-16T22:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","state":"CO","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":"sam_street","state_evidence":"DEPARTMENT OF VETERANS AFFAIRS ROCKY MOUNTAIN VA MEDICAL CENTER 1700 N WHEELING ST. AURORA, CO 80045","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-02T14:33:52.402542Z","principal_notice_id":"e4815f8e559e49a5990d0f7854ac7c8a","description":{"text":"Sources Sought Notice - Research Anaerobic Chamber Purchase for Rocky Mountain Regional VA Regional Medical Center (RMRVAMC)\nDisclaimer:\nThis Request for Information (RFI) is issued solely for market research information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are NOT offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\n\nInformation Requested from Industry:\n\nIn response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List.\n\nResponses to market research table questionnaire shall be submitted. If this information is not provided, then it will be assumed the entire requirement cannot be met.\n\nDepartment of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for Research Anaerobic Chamber Purchase for Rocky Mountain VA Medical Center. This Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided.\n\nResearch Anaerobic Chamber Purchase Qty 1. The offer must meet the following salient characteristics:\nDescription\nUnit\nQty\nAnaerobic Chamber\nEA\n1\n\nSaliant features that are minimum technically required:\nElectrical will be standard 120V plug\nInterior Dimensions (equal or greater to): 55 x 31 x 40 (width x depth x height). Depth max is 34\nInterior volume (equal or greater to): 210 liters\nAirlock dimensions (equal or greater to): 12 x 14 x 11 inches (width x depth x height) to accommodate our sample containers\nActivated Carbon/O2 palladium cartridge scrubber\nSide access panel\nLow gas supply alarm and leak detection alarm\nEstablish <10ppm O2 in less than 1 hour to accommodate sporadic specimen delivery and need to process within 2 hrs.\nPurge cycle of 90 seconds\nSet up for gloveless sleeves or optional cuff for direct hand access\nGas tank floor restraint\nPressurized gas regulators and gas tank fittings.\nSufficient supplies and catalyst for one year of operation.\nIf the unit requires an oven system for regeneration of catalyst, that should be included with 120V plug. Max depth is 34 .\nSystem must come with a one year warranty\n\nDelivery:\nDepartment of Veterans Affairs\nRocky Mountain Regional VA Medical Center\n1700 N. Wheeling Street\nAurora, CO, 80045\n\nIn response to this announcement, please provide the information requested below requested in this market research table questionnaire. If this information is not provided, then it will be assumed the entire requirement cannot be met:\nNAICS Code:\nCompany Name:\nAddress:\nUEI (Unique Entity ID) Number:\nContact Name:\nPhone No.:\nEmail:\nBusiness Size Information - Select all that applies:\nSmall Business\nEmerging Small Business\nSmall Disadvantaged Business\nCertified under Section 8(a) of the Small Business Act\nHUBZone\nWoman Owned\nCertified Service-Disabled Veteran Owned Small\nVeteran Owned Small Business\nLarge Business\nFSS/GSA Contract Holder:\nYes No\nFSS/GSA Contract Number:\n\nEffective Date/ Expiration Date:\n\nProposed solution is listed and available on the above FSS/GSA Contract:\nYes No\nPricing Model\nPlease Indicate Availability Below: (Yes / No / NA)\nAll on FSS\nOpen Market only\nMix of FSS & Open Market\nFirm-Fixed Price\n\nFederal Acquisition Regulation (FAR) Market Rearch Questions:\n\nBuy American Act RFO 52.225-1 and RFO 52.225-2 Buy American Certificate What percentage of the proposed product (including leases and rentals) is a:\n\nDomestic end product? _____________ (%)\n\nForeign end product? _______________ (%) Country of Origin:\n\nQuestions for Small Businesses ONLY:\n\nIf subcontracting, what added value do you offer (RFO 52.215-23):\n\nNonmanufacturer Rule (RFO 52.219-33):\nDoes your company manufacturer these proposed items? [Â ] yes [Â ] no\nDoes your company exceed 500 employees? [Â ] yes [Â ] no If yes, list # of employees: _________\nDoes your company primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied? [Â ] yes [Â ] no\nDoes your company take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? [Â ] yes [Â ] no\nDoes your company supply the end item of a small business manufacturer, processor or producer made in the United States, or obtains a waiver of such requirement pursuant to paragraph (b)(5) CFR 121.406. [Â ] yes [Â ] no If yes, what is the manufacturer s name? ________________\n\nResponse Instructions:\nDo not provide more than 8 pages, including cover letter page.\nSubmit your response via email to devin.reichert@va.gov\nSubmit your response NLT 4:00 (MST) on Tuesday, June 16, 2026;\nMark your response as Proprietary Information if the information is considered business sensitive.\nVA has identified the appropriate North American Industry Classification System (NAICS) Code as 334516 Analytical Laboratory Instrument Manufacturing with a Small Business size of 1000 Employees. Please identify and explain any NAICS codes your company believes would better represent the predominant work included in the attached Statement of Work draft / Salient Characteristics List.\n\n(End of Document)","html":"Sources Sought Notice - Research Anaerobic Chamber Purchase for Rocky Mountain Regional VA Regional Medical Center (RMRVAMC)\nDisclaimer:\nThis Request for Information (RFI) is issued solely for market research information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are NOT offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\n\nInformation Requested from Industry:\n\nIn response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List.\n\nResponses to market research table questionnaire shall be submitted. If this information is not provided, then it will be assumed the entire requirement cannot be met.\n\nDepartment of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for Research Anaerobic Chamber Purchase for Rocky Mountain VA Medical Center. This Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided. \n\nResearch Anaerobic Chamber Purchase   Qty 1. The offer must meet the following salient characteristics:\nDescription\nUnit\nQty\nAnaerobic Chamber \nEA\n1\n\n\n\nSaliant features that are minimum technically required:\nElectrical will be standard 120V plug\nInterior Dimensions (equal or greater to): 55  x  31  x 40  (width x depth x height).  Depth max is 34 \nInterior volume (equal or greater to): 210 liters\nAirlock dimensions (equal or greater to): 12  x 14  x 11  inches (width x depth x height) to accommodate our sample containers\nActivated Carbon/O2 palladium cartridge scrubber\nSide access panel\nLow gas supply alarm and leak detection alarm\nEstablish <10ppm O2 in less than 1 hour to accommodate sporadic specimen delivery and need to process within 2 hrs. \nPurge cycle of 90 seconds\nSet up for gloveless sleeves or optional cuff for direct hand access\nGas tank floor restraint \nPressurized gas regulators and gas tank fittings.\nSufficient supplies and catalyst for one year of operation.\nIf the unit requires an oven system for regeneration of catalyst, that should be included with 120V plug.  Max depth is 34 .\nSystem must come with a one year warranty\n\nDelivery:\nDepartment of Veterans Affairs\nRocky Mountain Regional VA Medical Center\n1700 N. Wheeling Street\nAurora, CO, 80045\n       \nIn response to this announcement, please provide the information requested below requested in this market research table questionnaire. If this information is not provided, then it will be assumed the entire requirement cannot be met: \nNAICS Code: \nCompany Name:\nAddress:\nUEI (Unique Entity ID) Number:\nContact Name:\nPhone No.:\nEmail:\nBusiness Size Information - Select all that applies:\nSmall Business\nEmerging Small Business\nSmall Disadvantaged Business\nCertified under Section 8(a) of the Small Business Act\nHUBZone\nWoman Owned\nCertified Service-Disabled Veteran Owned Small\nVeteran Owned Small Business\nLarge Business\nFSS/GSA Contract Holder:\nYes                     No    \nFSS/GSA Contract Number:\n\nEffective Date/ Expiration Date:\n\nProposed solution is listed and available on the above FSS/GSA Contract:\nYes                     No    \nPricing Model\nPlease Indicate Availability Below: (Yes / No / NA)\nAll on FSS\nOpen Market only\nMix of FSS & Open Market\nFirm-Fixed Price\n\n\n\nFederal Acquisition Regulation (FAR) Market Rearch Questions:\n\n\n\nBuy American Act RFO 52.225-1 and RFO 52.225-2 Buy American Certificate   What percentage of the proposed product (including leases and rentals) is a:\n\n\n\nDomestic end product? _____________ (%)\n\n\n\nForeign end product? _______________ (%) Country of Origin:\n\n\n\nQuestions for Small Businesses ONLY:\n\n\n\nIf subcontracting, what added value do you offer (RFO 52.215-23): \n\n\n\nNonmanufacturer Rule (RFO 52.219-33):\nDoes your company manufacturer these proposed items? [Â  ] yes [Â  ] no\nDoes your company exceed 500 employees?  [Â  ] yes [Â  ] no   If yes, list # of employees: _________\nDoes your company primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied?  [Â  ] yes [Â  ] no\nDoes your company take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice?  [Â  ] yes [Â  ] no\nDoes your company supply the end item of a small business manufacturer, processor or producer made in the United States, or obtains a waiver of such requirement pursuant to paragraph (b)(5) CFR 121.406. [Â  ] yes [Â  ] no  If yes, what is the manufacturer s name? ________________ \n\n\nResponse Instructions:\nDo not provide more than 8 pages, including cover letter page.\nSubmit your response via email to devin.reichert@va.gov \nSubmit your response NLT 4:00 (MST) on Tuesday, June 16, 2026;\nMark your response as  Proprietary Information  if the information is considered business sensitive.\nVA has identified the appropriate North American Industry Classification System (NAICS) Code as 334516   Analytical Laboratory Instrument Manufacturing with a Small Business size of 1000 Employees.  Please identify and explain any NAICS codes your company believes would better represent the predominant work included in the attached Statement of Work draft / Salient Characteristics List.\n\n(End of Document)","origin":"detail"},"contacts":[{"name":"Devin Reichert","role":"primary","email":"Devin.Reichert@va.gov","phone":"303-712-5709","title":"Contract Specialist"}],"place_of_performance":{"street":"Department of Veterans Affairs Rocky Mountain VA Medical Center","street2":"1700 N Wheeling St. Aurora, CO 80045"},"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"naics_codes":["334516"],"award":{"awardee":{}},"attachments":[{"resource_id":"f838598b3bec4b368771e7bab3b92da0","name":"36C25926Q0526.docx","kind":"file","mime_type":".docx","size_bytes":23561,"posted_at":"2026-06-09T15:05:08.362Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/f838598b3bec4b368771e7bab3b92da0/download","mirrored":false}],"awards":[],"related":[{"key":"36C25927Q0058","latest_notice_id":"f7ba8da853564af6a36ca00b9a898459","title":"Q301--NEW | Automated Blood Bank Solid Phase Analyzer and Associated Reagents/Consumables","solicitation_number":"36C25927Q0058","notice_type":"r","first_type":"r","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-25T22:30:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T22:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"334516","psc":"Q301","set_aside":null,"state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"36C25927Q0048","latest_notice_id":"c63e9c1e32f4475caa79c878ba87ca2f","title":"Radiant Heating Panel Replacement","solicitation_number":"36C25927Q0048","notice_type":"k","first_type":"k","first_posted":"2026-11-04","last_posted":"2026-11-23","notices":3,"due_at":"2026-11-27T19:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"238220","psc":"J045","set_aside":"SBA","state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C25927Q0061","latest_notice_id":"2844a59e27da407db5c5aac404bd35d7","title":"AI tool for Medication Reconciliation and Clinical Review","solicitation_number":"36C25927Q0061","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"541519","psc":"DA10","set_aside":null,"state":"CO","county":"08077","county_name":"Mesa County","city":"0831660","city_name":"Grand Junction","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C25927Q0060","latest_notice_id":"dab1ae13fa4543da8629e3ba28875296","title":"J023-- Transmission Repair/Replacement x2","solicitation_number":"36C25927Q0060","notice_type":"k","first_type":"k","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-12-04T17:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"811111","psc":"J023","set_aside":"SBA","state":"UT","county":"49035","county_name":"Salt Lake County","city":"4967000","city_name":"Salt Lake City","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C25927Q0063","latest_notice_id":"3aec52f34d1346bcb89262decf41e0e9","title":"J045--Annual Boiler Maintenance RMR VAMC","solicitation_number":"36C25927Q0063","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-04T21:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"238220","psc":"J045","set_aside":null,"state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":"sam_zip","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open":[{"key":"36C25927Q0058","latest_notice_id":"f7ba8da853564af6a36ca00b9a898459","title":"Q301--NEW | Automated Blood Bank Solid Phase Analyzer and Associated Reagents/Consumables","solicitation_number":"36C25927Q0058","notice_type":"r","first_type":"r","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-25T22:30:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T22:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"334516","psc":"Q301","set_aside":null,"state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"68HE0827Q0004","latest_notice_id":"63a64060adcf418a92c3240f32cfd547","title":"Region 8 Laboratory - SampleSense base modules and","solicitation_number":"68HE0827Q0004","notice_type":"o","first_type":"o","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-30T21:30:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T21:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-068","dept_name":"ENVIRONMENTAL PROTECTION AGENCY","sub_key":"s-6800","sub_name":"ENVIRONMENTAL PROTECTION AGENCY","office_key":"o-68HE08","office_name":"REGION 8 CONTRACTING OFFICE","naics":"334516","psc":"6640","set_aside":"SBA","state":"CO","county":"08031","county_name":"Denver County","city":"0820000","city_name":"Denver","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"573067270009","latest_notice_id":"ff7a062def984637aae7109d5026d17c","title":"Sources Sought: Polarization-Entangled Photon Source","solicitation_number":"573067-27-0009","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":3,"due_at":"2026-12-04T19:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6035","set_aside":null,"state":"CO","county":"08013","county_name":"Boulder County","city":"0807850","city_name":"Boulder","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"}],"similar_open_total":58,"indexable":false}