{"canonical":"https://sealedbidder.com/opportunities/36c25926q0221","key":"36C25926Q0221","url":"https://sealedbidder.com/opportunities/36c25926q0221","title":"6515--ACIST CVi Contrast Dye Injector System","solicitation_number":"36C25926Q0221","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-02-06T17:00:00Z","first_posted":"2026-01-30","last_posted":"2026-01-30","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"339112","psc":"6515","set_aside":null,"place_state":"CO","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"08001","place_county_name":"Adams County","place_city":"0804000","place_city_name":"Aurora","winner":null,"award_amount":null,"publications":[{"notice_id":"45e3ce3236f244879f522c5b0fe36a18","title":"6515--ACIST CVi Contrast Dye Injector System","solicitation_number":"36C25926Q0221","notice_type":"r","base_type":"r","posted":"2026-01-30","posted_at":"2026-01-30T14:13:26.614Z","due_at":"2026-02-06T17:00:00Z","due_date":"2026-02-06","cancelled":false,"archived":true,"archive_date":"2026-03-08","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/45e3ce3236f244879f522c5b0fe36a18/view","enriched":true,"history":[{"index":3,"title":"6515--ACIST CVi Contrast Dye Injector System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-30T14:13:26.614Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"45e3ce3236f244879f522c5b0fe36a18","solicitation_number":"36C25926Q0221"}]}],"latest_notice_id":"45e3ce3236f244879f522c5b0fe36a18","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-01-30","posted_at":"2026-01-30T14:13:26.614Z","created_at":"2026-01-30T14:13:24.356Z","modified_at":"2026-03-09T04:00:05.271Z","response_deadline":{"raw":"2026-02-06T10:00:00-07:00","utc":"2026-02-06T17:00:00Z","date":"2026-02-06","time":"10:00:00","timezone":"America/Denver","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/45e3ce3236f244879f522c5b0fe36a18/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"6515--ACIST CVi Contrast Dye Injector System","agency":{"office":{"code":"36C259","name":"NETWORK CONTRACT OFFICE 19 (36C259)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"organization_id":"100176750","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-03-08","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--ACIST CVi Contrast Dye Injector System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-30T14:13:26.614Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"45e3ce3236f244879f522c5b0fe36a18","solicitation_number":"36C25926Q0221"}],"contacts":[{"name":"Noaa Lanotte","role":"primary","email":"Noaa.Lanotte@va.gov","phone":"303-712-5794","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"45e3ce3236f244879f522c5b0fe36a18","lineage_id":"45e3ce3236f244879f522c5b0fe36a18","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-14T08:18:36.782175033Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"d709c8db8650bb8fe67f2b90b52af136e35d148aa9ac40ffb7f4602fcaf23435","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-14T08:18:36.782175033Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"The Department of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for ACIST CVi Contrast Dye Injector (brand name or equal) for the Rocky Mountain Regional VA Medical Center. This Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided. \nSalient Characteristics:\n\n-Multi-use syringe usage\n-Power requirements factory selectable 100 to 120 VAC, 50-60 Hz\n-10 A maximum or 200 to 240 VAC, 50-60 Hz\n-Up to a 30% reduction in contrast delivered to patient without compromising image quality\n-Real-time Dose Tracking\n-Hand Controller with Variable Rate Technology\n-Smaller Catheter use option\n-Twelve design elements that mitigate air injection during angiography\n-Multi-use syringe usage\n-Air Column Detect sensor\n-Manifold capability to prevent reverse flow\n-Automatic hemodynamic monitoring capability\n-Contrast flow rates: user-responsive, pre-set Variable and Fixed rates\n-Fixed saline flow rates\n-Injection modes: Cardiac & Peripheral Vascular\n-Pressure Limits minimum 200 to 1200psi\n-Allow contrast syringe for use in up to 6 patient cases\n-Single and dual pressure monitoring capability\n\nThe purchase shall include manufacturer s warranty for the life of the equipment that begins on the date of installation. Warranty shall include the following:\nPreventive maintenance must be done by OEM certified technicians using OEM certified parts and should at minimum include the following:\n Annually:\n  -Full system calibration and diagnostics\n  -Software updates and hardware firmware verification\n  -Inspection and replacement of internal filters\n  -Verification of pressure sensor accuracy\n  -Inspection of electrical components and mechanical joints\n  -Safety checks\n   -Grounding integrity\n   -Emergency shutoff verification\n  As Needed:\n  OEM Repair Services\n  Error Code Response and Diagnostics\n \nPart Number(s):\nCLIN\nPart Number\nNomenclature\nUnit of Measure\nQuantity\n0001\n019398\nACIST CVi Contrast Dye Injector System with 7-year Warranty (Brand Name or Equal)\nEA\n1\n\n\nResponses shall be submitted to Noaa.Lanotte@va.gov by 10:00am MT on February 6, 2026. \n\nThis notice is intended strictly for market research. The purpose of this Sources Sought Notice is to determine interest and capability of potential qualified sources of supply and determine the socioeconomic size classification of the supplier and manufacturer of the end item.\n\nInterested companies shall provide, at a minimum, the following information with their response; \n\nCompany Name and Address:\nPoint of Contact (POC)\nName:\nEmail Address:\nPhone Number:\nSAM.gov UEI:\nOn GSA/FSS Schedule or VA Contract?\nManufactured in the USA?\n\nThe anticipated North American Industry Classification System (NAICS) code is 339112- Surgical and Medical Instrument Manufacturing. Mark if your firm is eligible for participation in one of the following small business programs. If so, please indicate the program: \n\n[ ] yes [ ] no - Small Business (SB)  \n[ ] yes [ ] no - HUBZone  \n[ ] yes [ ] no - Small Business 8(a)  \n[ ] yes [ ] no - Small Disadvantaged Business (SDB)  \n[ ] yes [ ] no - Women-Owned (WO) Small Business \n[ ] yes [ ] no - Service Disabled Veteran Owned Small Business (SDVOSB) \n[ ] yes [ ] no - Veteran Owned Small Business (VOSB)\n[ ] yes [ ] no - Large Business  \n[ ] yes [ ] no - Other (please specify)  \n\nPlease answer the following questions:\n\n[  ] yes [  ] no - Does not exceed 500 employees; (for NAICS 339112), must be verifiable thru the System for Award Management)\n\n[  ] yes [  ] no - Is primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied; \n\n[  ] yes [  ] no - Takes ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice (identify how this occurs); and \n\n[  ] yes [  ] no - Will supply the end item of a small business manufacturer, processor or producer made in the United States, or obtains a waiver of such requirement pursuant to paragraph (b)(5) CFR 121.406.\n\nPlace of Manufacture:____________________________\n\nNote: Do not include Proprietary, classified, confidential, or sensitive information in responses.\n\nIn addition to providing the information requested above, responding companies are encouraged to include any relevant information (specifications, cut sheets, brochures, capability statement, past experience etc.) to confirm the company s ability to meet the requirements outlined in this request. \n\nResponses to this notice are not offers and cannot be accepted by the U.S. Government to form a binding contract or agreement. This notice shall not be construed as a commitment by the Government to issue a solicitation, or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued.","text":"The Department of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for ACIST CVi Contrast Dye Injector (brand name or equal) for the Rocky Mountain Regional VA Medical Center. This Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided.\nSalient Characteristics:\n\n-Multi-use syringe usage\n-Power requirements factory selectable 100 to 120 VAC, 50-60 Hz\n-10 A maximum or 200 to 240 VAC, 50-60 Hz\n-Up to a 30% reduction in contrast delivered to patient without compromising image quality\n-Real-time Dose Tracking\n-Hand Controller with Variable Rate Technology\n-Smaller Catheter use option\n-Twelve design elements that mitigate air injection during angiography\n-Multi-use syringe usage\n-Air Column Detect sensor\n-Manifold capability to prevent reverse flow\n-Automatic hemodynamic monitoring capability\n-Contrast flow rates: user-responsive, pre-set Variable and Fixed rates\n-Fixed saline flow rates\n-Injection modes: Cardiac & Peripheral Vascular\n-Pressure Limits minimum 200 to 1200psi\n-Allow contrast syringe for use in up to 6 patient cases\n-Single and dual pressure monitoring capability\n\nThe purchase shall include manufacturer s warranty for the life of the equipment that begins on the date of installation. Warranty shall include the following:\nPreventive maintenance must be done by OEM certified technicians using OEM certified parts and should at minimum include the following:\nAnnually:\n-Full system calibration and diagnostics\n-Software updates and hardware firmware verification\n-Inspection and replacement of internal filters\n-Verification of pressure sensor accuracy\n-Inspection of electrical components and mechanical joints\n-Safety checks\n-Grounding integrity\n-Emergency shutoff verification\nAs Needed:\nOEM Repair Services\nError Code Response and Diagnostics\n\nPart Number(s):\nCLIN\nPart Number\nNomenclature\nUnit of Measure\nQuantity\n0001\n019398\nACIST CVi Contrast Dye Injector System with 7-year Warranty (Brand Name or Equal)\nEA\n1\n\nResponses shall be submitted to Noaa.Lanotte@va.gov by 10:00am MT on February 6, 2026.\n\nThis notice is intended strictly for market research. The purpose of this Sources Sought Notice is to determine interest and capability of potential qualified sources of supply and determine the socioeconomic size classification of the supplier and manufacturer of the end item.\n\nInterested companies shall provide, at a minimum, the following information with their response;\n\nCompany Name and Address:\nPoint of Contact (POC)\nName:\nEmail Address:\nPhone Number:\nSAM.gov UEI:\nOn GSA/FSS Schedule or VA Contract?\nManufactured in the USA?\n\nThe anticipated North American Industry Classification System (NAICS) code is 339112- Surgical and Medical Instrument Manufacturing. Mark if your firm is eligible for participation in one of the following small business programs. If so, please indicate the program:\n\n[ ] yes [ ] no - Small Business (SB)\n[ ] yes [ ] no - HUBZone\n[ ] yes [ ] no - Small Business 8(a)\n[ ] yes [ ] no - Small Disadvantaged Business (SDB)\n[ ] yes [ ] no - Women-Owned (WO) Small Business\n[ ] yes [ ] no - Service Disabled Veteran Owned Small Business (SDVOSB)\n[ ] yes [ ] no - Veteran Owned Small Business (VOSB)\n[ ] yes [ ] no - Large Business\n[ ] yes [ ] no - Other (please specify)\n\nPlease answer the following questions:\n\n[ ] yes [ ] no - Does not exceed 500 employees; (for NAICS 339112), must be verifiable thru the System for Award Management)\n\n[ ] yes [ ] no - Is primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied;\n\n[ ] yes [ ] no - Takes ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice (identify how this occurs); and\n\n[ ] yes [ ] no - Will supply the end item of a small business manufacturer, processor or producer made in the United States, or obtains a waiver of such requirement pursuant to paragraph (b)(5) CFR 121.406.\n\nPlace of Manufacture:____________________________\n\nNote: Do not include Proprietary, classified, confidential, or sensitive information in responses.\n\nIn addition to providing the information requested above, responding companies are encouraged to include any relevant information (specifications, cut sheets, brochures, capability statement, past experience etc.) to confirm the company s ability to meet the requirements outlined in this request.\n\nResponses to this notice are not offers and cannot be accepted by the U.S. Government to form a binding contract or agreement. This notice shall not be construed as a commitment by the Government to issue a solicitation, or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25926Q0221","place_of_performance":{"zip":"80045","city":{"code":"4000","name":"Aurora"},"state":{"code":"CO","name":"Colorado"},"street":"Department of Veterans Affairs Eastern Colorado VA Health Care System","country":{"code":"USA","name":"UNITED STATES"},"street2":"Rocky Mountain Regional Medical Center 1700 North Wheeling Street"},"product_service_code":"6515"}],"due_at":"2026-02-06T17:00:00Z","due_date":"2026-02-06","closes_at":"2026-02-06T17:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-14T08:49:08.412Z","principal_notice_id":"45e3ce3236f244879f522c5b0fe36a18","description":{"text":"The Department of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for ACIST CVi Contrast Dye Injector (brand name or equal) for the Rocky Mountain Regional VA Medical Center. This Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided.\nSalient Characteristics:\n\n-Multi-use syringe usage\n-Power requirements factory selectable 100 to 120 VAC, 50-60 Hz\n-10 A maximum or 200 to 240 VAC, 50-60 Hz\n-Up to a 30% reduction in contrast delivered to patient without compromising image quality\n-Real-time Dose Tracking\n-Hand Controller with Variable Rate Technology\n-Smaller Catheter use option\n-Twelve design elements that mitigate air injection during angiography\n-Multi-use syringe usage\n-Air Column Detect sensor\n-Manifold capability to prevent reverse flow\n-Automatic hemodynamic monitoring capability\n-Contrast flow rates: user-responsive, pre-set Variable and Fixed rates\n-Fixed saline flow rates\n-Injection modes: Cardiac & Peripheral Vascular\n-Pressure Limits minimum 200 to 1200psi\n-Allow contrast syringe for use in up to 6 patient cases\n-Single and dual pressure monitoring capability\n\nThe purchase shall include manufacturer s warranty for the life of the equipment that begins on the date of installation. Warranty shall include the following:\nPreventive maintenance must be done by OEM certified technicians using OEM certified parts and should at minimum include the following:\nAnnually:\n-Full system calibration and diagnostics\n-Software updates and hardware firmware verification\n-Inspection and replacement of internal filters\n-Verification of pressure sensor accuracy\n-Inspection of electrical components and mechanical joints\n-Safety checks\n-Grounding integrity\n-Emergency shutoff verification\nAs Needed:\nOEM Repair Services\nError Code Response and Diagnostics\n\nPart Number(s):\nCLIN\nPart Number\nNomenclature\nUnit of Measure\nQuantity\n0001\n019398\nACIST CVi Contrast Dye Injector System with 7-year Warranty (Brand Name or Equal)\nEA\n1\n\nResponses shall be submitted to Noaa.Lanotte@va.gov by 10:00am MT on February 6, 2026.\n\nThis notice is intended strictly for market research. The purpose of this Sources Sought Notice is to determine interest and capability of potential qualified sources of supply and determine the socioeconomic size classification of the supplier and manufacturer of the end item.\n\nInterested companies shall provide, at a minimum, the following information with their response;\n\nCompany Name and Address:\nPoint of Contact (POC)\nName:\nEmail Address:\nPhone Number:\nSAM.gov UEI:\nOn GSA/FSS Schedule or VA Contract?\nManufactured in the USA?\n\nThe anticipated North American Industry Classification System (NAICS) code is 339112- Surgical and Medical Instrument Manufacturing. Mark if your firm is eligible for participation in one of the following small business programs. If so, please indicate the program:\n\n[ ] yes [ ] no - Small Business (SB)\n[ ] yes [ ] no - HUBZone\n[ ] yes [ ] no - Small Business 8(a)\n[ ] yes [ ] no - Small Disadvantaged Business (SDB)\n[ ] yes [ ] no - Women-Owned (WO) Small Business\n[ ] yes [ ] no - Service Disabled Veteran Owned Small Business (SDVOSB)\n[ ] yes [ ] no - Veteran Owned Small Business (VOSB)\n[ ] yes [ ] no - Large Business\n[ ] yes [ ] no - Other (please specify)\n\nPlease answer the following questions:\n\n[ ] yes [ ] no - Does not exceed 500 employees; (for NAICS 339112), must be verifiable thru the System for Award Management)\n\n[ ] yes [ ] no - Is primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied;\n\n[ ] yes [ ] no - Takes ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice (identify how this occurs); and\n\n[ ] yes [ ] no - Will supply the end item of a small business manufacturer, processor or producer made in the United States, or obtains a waiver of such requirement pursuant to paragraph (b)(5) CFR 121.406.\n\nPlace of Manufacture:____________________________\n\nNote: Do not include Proprietary, classified, confidential, or sensitive information in responses.\n\nIn addition to providing the information requested above, responding companies are encouraged to include any relevant information (specifications, cut sheets, brochures, capability statement, past experience etc.) to confirm the company s ability to meet the requirements outlined in this request.\n\nResponses to this notice are not offers and cannot be accepted by the U.S. Government to form a binding contract or agreement. This notice shall not be construed as a commitment by the Government to issue a solicitation, or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued.","html":"The Department of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for ACIST CVi Contrast Dye Injector (brand name or equal) for the Rocky Mountain Regional VA Medical Center. This Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided. \nSalient Characteristics:\n\n-Multi-use syringe usage\n-Power requirements factory selectable 100 to 120 VAC, 50-60 Hz\n-10 A maximum or 200 to 240 VAC, 50-60 Hz\n-Up to a 30% reduction in contrast delivered to patient without compromising image quality\n-Real-time Dose Tracking\n-Hand Controller with Variable Rate Technology\n-Smaller Catheter use option\n-Twelve design elements that mitigate air injection during angiography\n-Multi-use syringe usage\n-Air Column Detect sensor\n-Manifold capability to prevent reverse flow\n-Automatic hemodynamic monitoring capability\n-Contrast flow rates: user-responsive, pre-set Variable and Fixed rates\n-Fixed saline flow rates\n-Injection modes: Cardiac & Peripheral Vascular\n-Pressure Limits minimum 200 to 1200psi\n-Allow contrast syringe for use in up to 6 patient cases\n-Single and dual pressure monitoring capability\n\nThe purchase shall include manufacturer s warranty for the life of the equipment that begins on the date of installation. Warranty shall include the following:\nPreventive maintenance must be done by OEM certified technicians using OEM certified parts and should at minimum include the following:\n Annually:\n  -Full system calibration and diagnostics\n  -Software updates and hardware firmware verification\n  -Inspection and replacement of internal filters\n  -Verification of pressure sensor accuracy\n  -Inspection of electrical components and mechanical joints\n  -Safety checks\n   -Grounding integrity\n   -Emergency shutoff verification\n  As Needed:\n  OEM Repair Services\n  Error Code Response and Diagnostics\n \nPart Number(s):\nCLIN\nPart Number\nNomenclature\nUnit of Measure\nQuantity\n0001\n019398\nACIST CVi Contrast Dye Injector System with 7-year Warranty (Brand Name or Equal)\nEA\n1\n\n\nResponses shall be submitted to Noaa.Lanotte@va.gov by 10:00am MT on February 6, 2026. \n\nThis notice is intended strictly for market research. The purpose of this Sources Sought Notice is to determine interest and capability of potential qualified sources of supply and determine the socioeconomic size classification of the supplier and manufacturer of the end item.\n\nInterested companies shall provide, at a minimum, the following information with their response; \n\nCompany Name and Address:\nPoint of Contact (POC)\nName:\nEmail Address:\nPhone Number:\nSAM.gov UEI:\nOn GSA/FSS Schedule or VA Contract?\nManufactured in the USA?\n\nThe anticipated North American Industry Classification System (NAICS) code is 339112- Surgical and Medical Instrument Manufacturing. Mark if your firm is eligible for participation in one of the following small business programs. If so, please indicate the program: \n\n[ ] yes [ ] no - Small Business (SB)  \n[ ] yes [ ] no - HUBZone  \n[ ] yes [ ] no - Small Business 8(a)  \n[ ] yes [ ] no - Small Disadvantaged Business (SDB)  \n[ ] yes [ ] no - Women-Owned (WO) Small Business \n[ ] yes [ ] no - Service Disabled Veteran Owned Small Business (SDVOSB) \n[ ] yes [ ] no - Veteran Owned Small Business (VOSB)\n[ ] yes [ ] no - Large Business  \n[ ] yes [ ] no - Other (please specify)  \n\nPlease answer the following questions:\n\n[  ] yes [  ] no - Does not exceed 500 employees; (for NAICS 339112), must be verifiable thru the System for Award Management)\n\n[  ] yes [  ] no - Is primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied; \n\n[  ] yes [  ] no - Takes ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice (identify how this occurs); and \n\n[  ] yes [  ] no - Will supply the end item of a small business manufacturer, processor or producer made in the United States, or obtains a waiver of such requirement pursuant to paragraph (b)(5) CFR 121.406.\n\nPlace of Manufacture:____________________________\n\nNote: Do not include Proprietary, classified, confidential, or sensitive information in responses.\n\nIn addition to providing the information requested above, responding companies are encouraged to include any relevant information (specifications, cut sheets, brochures, capability statement, past experience etc.) to confirm the company s ability to meet the requirements outlined in this request. \n\nResponses to this notice are not offers and cannot be accepted by the U.S. Government to form a binding contract or agreement. This notice shall not be construed as a commitment by the Government to issue a solicitation, or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued.","origin":"detail"},"contacts":[{"name":"Noaa Lanotte","role":"primary","email":"Noaa.Lanotte@va.gov","phone":"303-712-5794","title":"Contracting Officer"}],"place_of_performance":{"zip":"80045","city":{"code":"4000","name":"Aurora"},"state":{"code":"CO","name":"Colorado"},"street":"Department of Veterans Affairs Eastern Colorado VA Health Care System","country":{"code":"USA","name":"UNITED STATES"},"street2":"Rocky Mountain Regional Medical Center 1700 North Wheeling Street"},"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"naics_codes":["339112"],"award":{"awardee":{}},"attachments":[{"resource_id":"b896dc4eadbe423d99e4127abfe0a10e","name":"36C25926Q0221.docx","kind":"file","mime_type":".docx","size_bytes":19080,"posted_at":"2026-01-30T14:13:26.614Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/b896dc4eadbe423d99e4127abfe0a10e/download","mirrored":false}],"awards":[],"related":[{"key":"36C25927Q0048","latest_notice_id":"c63e9c1e32f4475caa79c878ba87ca2f","title":"Radiant Heating Panel Replacement","solicitation_number":"36C25927Q0048","notice_type":"k","first_type":"k","first_posted":"2026-11-04","last_posted":"2026-11-23","notices":3,"due_at":"2026-11-27T19:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"238220","psc":"J045","set_aside":"SBA","state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C25927Q0061","latest_notice_id":"2844a59e27da407db5c5aac404bd35d7","title":"AI tool for Medication Reconciliation and Clinical Review","solicitation_number":"36C25927Q0061","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"541519","psc":"DA10","set_aside":null,"state":"CO","county":"08077","county_name":"Mesa County","city":"0831660","city_name":"Grand Junction","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C25927Q0060","latest_notice_id":"dab1ae13fa4543da8629e3ba28875296","title":"J023-- Transmission Repair/Replacement x2","solicitation_number":"36C25927Q0060","notice_type":"k","first_type":"k","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-12-04T17:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"811111","psc":"J023","set_aside":"SBA","state":"UT","county":"49035","county_name":"Salt Lake County","city":"4967000","city_name":"Salt Lake City","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C25927Q0063","latest_notice_id":"3aec52f34d1346bcb89262decf41e0e9","title":"J045--Annual Boiler Maintenance RMR VAMC","solicitation_number":"36C25927Q0063","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-04T21:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"238220","psc":"J045","set_aside":null,"state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C25927Q0051","latest_notice_id":"65781a346f1d408a8306e07a5b7f57e4","title":"Q301--Request For Information (RFI)-Reference Lab Testing for Fort Harrison VA Medical Center (Fort Harrison, MT)","solicitation_number":"36C25927Q0051","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-12-11T17:00:00Z","due_date":"2026-12-11","closes_at":"2026-12-11T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"541380","psc":"Q301","set_aside":null,"state":"MT","county":"30049","county_name":"Lewis and Clark County","city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T07:05:42.989249Z"}],"similar_open":[{"key":"W911S227U0200","latest_notice_id":"153aef7d00e740188276deb8422a2297","title":"Automated External Defibrillator (AED)","solicitation_number":"W911S227U0200","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T20:15:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:15:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24727Q0119","latest_notice_id":"81776fecabf149c9867d6253acdc2478","title":"Vivarium Tunnel Washer","solicitation_number":"36C24727Q0119","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"339112","psc":"6640","set_aside":null,"state":"GA","county":"13089","county_name":"DeKalb County","city":"1322052","city_name":"Decatur","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C10X27Q0025","latest_notice_id":"8c404062fbbc4212bb93120ad204ee50","title":"6515--NX EQ Microscope, Light, Operating, Hand/Plastic Surgery (VA-27-00017958)","solicitation_number":"36C10X27Q0025","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"}],"similar_open_total":16,"indexable":false}