{"canonical":"https://sealedbidder.com/opportunities/36c25925q0822","key":"36C25925Q0822","url":"https://sealedbidder.com/opportunities/36c25925q0822","title":"6515--PND 10-31-2025 Actionable-436-S/S high Fidelity manikin (VA-25-00094659)","solicitation_number":"36C25925Q0822","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-10-03T18:00:00Z","first_posted":"2025-09-24","last_posted":"2025-09-24","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"339112","psc":"6515","set_aside":null,"place_state":"MT","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"30049","place_county_name":"Lewis and Clark County","place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"988f6f1b027a4e9c9857ae29c34070a3","title":"6515--PND 10-31-2025 Actionable-436-S/S high Fidelity manikin (VA-25-00094659)","solicitation_number":"36C25925Q0822","notice_type":"r","base_type":"r","posted":"2025-09-24","posted_at":"2025-09-24T15:00:59.363Z","due_at":"2025-10-03T18:00:00Z","due_date":"2025-10-03","cancelled":false,"archived":true,"archive_date":"2025-12-02","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/988f6f1b027a4e9c9857ae29c34070a3/view","enriched":true,"history":[{"index":3,"title":"6515--PND 10-31-2025 Actionable-436-S/S high Fidelity manikin (VA-25-00094659)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-24T15:00:59.363Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"988f6f1b027a4e9c9857ae29c34070a3","solicitation_number":"36C25925Q0822"}]}],"latest_notice_id":"988f6f1b027a4e9c9857ae29c34070a3","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-09-24","posted_at":"2025-09-24T15:00:59.363Z","created_at":"2025-09-24T15:00:57.129Z","modified_at":"2025-12-02T05:04:36.841Z","response_deadline":{"raw":"2025-10-03T12:00:00-06:00","utc":"2025-10-03T18:00:00Z","date":"2025-10-03","time":"12:00:00","timezone":"America/Denver","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/988f6f1b027a4e9c9857ae29c34070a3/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"6515--PND 10-31-2025 Actionable-436-S/S high Fidelity manikin (VA-25-00094659)","agency":{"office":{"code":"36C259","name":"NETWORK CONTRACT OFFICE 19 (36C259)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"organization_id":"100176750","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-12-02","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--PND 10-31-2025 Actionable-436-S/S high Fidelity manikin (VA-25-00094659)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-24T15:00:59.363Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"988f6f1b027a4e9c9857ae29c34070a3","solicitation_number":"36C25925Q0822"}],"contacts":[{"name":"Barron Long","role":"primary","email":"barron.long@va.gov","phone":"303-712-5741","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"988f6f1b027a4e9c9857ae29c34070a3","lineage_id":"988f6f1b027a4e9c9857ae29c34070a3","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-28T02:55:14.410588557Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"03079db76d6b53b3311e8a4542182874c9e72ad87b177e820d0d240160b2cc7a","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-10-28T02:55:14.410588557Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Sources Sought Notice   HI-FIDELITY MANIKIN\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nResponse Instructions:\nDo not provide more than 8 pages, including cover letter page.\nSubmit your response via email to: barron.long@va.gov\nSubmit your response NLT 12:00 (MST) on Friday, October 3rd 12:00 local mountain time\nMark your response as  Proprietary Information  if the information is considered business sensitive.\nVA has identified the appropriate North American Industry Classification System (NAICS) Code 339112 Surgical and Medical Instrument Manufacturing with a Small Business size of 1000 employees.  Please identify and explain any NAICS codes your company believes would better represent the predominated work included in the attached Statement of Work draft / Salient Characteristics List;\n\nInformation Requested from Industry:\n\nIn response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List.\n\n\nVendor Name:\n\nSAM UEI #:\n\nName of Manufacturer:\n\nManufacturer Address:\n\nManufacturing Country of Origin\nEstimated Delivery Time:\n___________________________________________________\nSAC FSS contract number\n\nVendor Point of Contract (POC) Name\n\nPOC Phone Number:\n\nPOC Email Address:\n\n\n\n\n\n\nSTATEMENT OF WORK\n\nREQUIREMENT \n-What is this requirement for? High fidelity manikin (HFM) for mock code training\n-Reason requirement is needed:\n -Situation-Directive 1177 Cardiopulmonary Resuscitation maintains policy to optimize patient safety for those requiring resuscitation within the Department of VA health care system.  The Resuscitation Education and Innovation (REdI) program is the official VHA national program which provides enterprise-wide oversight and support.   REdI requires a mock code program is implemented across all areas of the VA medical facility\n -What will the period of performance be for this requirement? One time purchase\n -Assessment-HFM is needed to adhere to Directive 1177 and the REdI program by providing training to optimize patient safety\n -Recommendation-Ensure a HFM in working order is available to continue to comply with the Directive and REdI requirements.  Current HFM is at end of life. \n\n-Quantities (equipment only): 1 Manikin\n\nDELIVERY INFORMATION\nMontana VAHCS: Fort Harrison VAMC\n3687 Veteran s Drive, Bldg. 150, room 107 \nFort Harrison, MT 59636\n\n\n\n\n\n\n\n\n\n\n\n\n\nSalient Characteristics\n\nThe High Fidelity Manikin (HFM) needs to demonstrate the following:\nSpontaneous breathing with unilateral and bilateral chest rise and fall.\nAllow for bilateral needle decompressions\nAllow for oral and nasal endotracheal intubation with right main stem detection\nAllow for bilateral needle decompression of lungs\nShow 4-lead and 12-lead cardiac rhythms\nAllow for unilateral blood pressure measurement by auscultation and palpitation\nBilateral carotid and femoral pulses, with variable intensity control\nUnilateral radial and brachial pulses, with variable intensity control\nAuscultation of normal and abnormal heart, lung and bowel sounds\nAudible Korotkoff sounds generated with NIBP\nTwo-way communication between manikin and facilitator\nPrerecorded speed and vocal sounds\nInterchangeable genitalia\nUrinary catheterization without fluids\nIV/IO arm and a NIBP/pulse arm\n4 intramuscular injection sites\nArticulating range of motion in hips, knees, ankles, shoulders\nMust be able to be cleaned with PDF Purple top wipes for disinfection. \nHFM needs to be compatible with CAE Maestro  software","text":"Sources Sought Notice HI-FIDELITY MANIKIN\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nResponse Instructions:\nDo not provide more than 8 pages, including cover letter page.\nSubmit your response via email to: barron.long@va.gov\nSubmit your response NLT 12:00 (MST) on Friday, October 3rd 12:00 local mountain time\nMark your response as Proprietary Information if the information is considered business sensitive.\nVA has identified the appropriate North American Industry Classification System (NAICS) Code 339112 Surgical and Medical Instrument Manufacturing with a Small Business size of 1000 employees. Please identify and explain any NAICS codes your company believes would better represent the predominated work included in the attached Statement of Work draft / Salient Characteristics List;\n\nInformation Requested from Industry:\n\nIn response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List.\n\nVendor Name:\n\nSAM UEI #:\n\nName of Manufacturer:\n\nManufacturer Address:\n\nManufacturing Country of Origin\nEstimated Delivery Time:\n___________________________________________________\nSAC FSS contract number\n\nVendor Point of Contract (POC) Name\n\nPOC Phone Number:\n\nPOC Email Address:\n\nSTATEMENT OF WORK\n\nREQUIREMENT\n-What is this requirement for? High fidelity manikin (HFM) for mock code training\n-Reason requirement is needed:\n-Situation-Directive 1177 Cardiopulmonary Resuscitation maintains policy to optimize patient safety for those requiring resuscitation within the Department of VA health care system. The Resuscitation Education and Innovation (REdI) program is the official VHA national program which provides enterprise-wide oversight and support. REdI requires a mock code program is implemented across all areas of the VA medical facility\n-What will the period of performance be for this requirement? One time purchase\n-Assessment-HFM is needed to adhere to Directive 1177 and the REdI program by providing training to optimize patient safety\n-Recommendation-Ensure a HFM in working order is available to continue to comply with the Directive and REdI requirements. Current HFM is at end of life.\n\n-Quantities (equipment only): 1 Manikin\n\nDELIVERY INFORMATION\nMontana VAHCS: Fort Harrison VAMC\n3687 Veteran s Drive, Bldg. 150, room 107\nFort Harrison, MT 59636\n\nSalient Characteristics\n\nThe High Fidelity Manikin (HFM) needs to demonstrate the following:\nSpontaneous breathing with unilateral and bilateral chest rise and fall.\nAllow for bilateral needle decompressions\nAllow for oral and nasal endotracheal intubation with right main stem detection\nAllow for bilateral needle decompression of lungs\nShow 4-lead and 12-lead cardiac rhythms\nAllow for unilateral blood pressure measurement by auscultation and palpitation\nBilateral carotid and femoral pulses, with variable intensity control\nUnilateral radial and brachial pulses, with variable intensity control\nAuscultation of normal and abnormal heart, lung and bowel sounds\nAudible Korotkoff sounds generated with NIBP\nTwo-way communication between manikin and facilitator\nPrerecorded speed and vocal sounds\nInterchangeable genitalia\nUrinary catheterization without fluids\nIV/IO arm and a NIBP/pulse arm\n4 intramuscular injection sites\nArticulating range of motion in hips, knees, ankles, shoulders\nMust be able to be cleaned with PDF Purple top wipes for disinfection.\nHFM needs to be compatible with CAE Maestro software","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25925Q0822","place_of_performance":{"zip":"59636","city":{"code":"28075","name":"Fort Harrison"},"state":{"code":"MT","name":"Montana"},"street":"Department of Veterans Affairs Fort Harrison VAMC","country":{"code":"USA","name":"UNITED STATES"},"street2":"3687 Veterans Drive"},"product_service_code":"6515"}],"due_at":"2025-10-03T18:00:00Z","due_date":"2025-10-03","closes_at":"2025-10-03T18:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","state":"MT","county":"30049","county_name":"Lewis and Clark County","city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-28T03:54:35.520081Z","principal_notice_id":"988f6f1b027a4e9c9857ae29c34070a3","description":{"text":"Sources Sought Notice HI-FIDELITY MANIKIN\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nResponse Instructions:\nDo not provide more than 8 pages, including cover letter page.\nSubmit your response via email to: barron.long@va.gov\nSubmit your response NLT 12:00 (MST) on Friday, October 3rd 12:00 local mountain time\nMark your response as Proprietary Information if the information is considered business sensitive.\nVA has identified the appropriate North American Industry Classification System (NAICS) Code 339112 Surgical and Medical Instrument Manufacturing with a Small Business size of 1000 employees. Please identify and explain any NAICS codes your company believes would better represent the predominated work included in the attached Statement of Work draft / Salient Characteristics List;\n\nInformation Requested from Industry:\n\nIn response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List.\n\nVendor Name:\n\nSAM UEI #:\n\nName of Manufacturer:\n\nManufacturer Address:\n\nManufacturing Country of Origin\nEstimated Delivery Time:\n___________________________________________________\nSAC FSS contract number\n\nVendor Point of Contract (POC) Name\n\nPOC Phone Number:\n\nPOC Email Address:\n\nSTATEMENT OF WORK\n\nREQUIREMENT\n-What is this requirement for? High fidelity manikin (HFM) for mock code training\n-Reason requirement is needed:\n-Situation-Directive 1177 Cardiopulmonary Resuscitation maintains policy to optimize patient safety for those requiring resuscitation within the Department of VA health care system. The Resuscitation Education and Innovation (REdI) program is the official VHA national program which provides enterprise-wide oversight and support. REdI requires a mock code program is implemented across all areas of the VA medical facility\n-What will the period of performance be for this requirement? One time purchase\n-Assessment-HFM is needed to adhere to Directive 1177 and the REdI program by providing training to optimize patient safety\n-Recommendation-Ensure a HFM in working order is available to continue to comply with the Directive and REdI requirements. Current HFM is at end of life.\n\n-Quantities (equipment only): 1 Manikin\n\nDELIVERY INFORMATION\nMontana VAHCS: Fort Harrison VAMC\n3687 Veteran s Drive, Bldg. 150, room 107\nFort Harrison, MT 59636\n\nSalient Characteristics\n\nThe High Fidelity Manikin (HFM) needs to demonstrate the following:\nSpontaneous breathing with unilateral and bilateral chest rise and fall.\nAllow for bilateral needle decompressions\nAllow for oral and nasal endotracheal intubation with right main stem detection\nAllow for bilateral needle decompression of lungs\nShow 4-lead and 12-lead cardiac rhythms\nAllow for unilateral blood pressure measurement by auscultation and palpitation\nBilateral carotid and femoral pulses, with variable intensity control\nUnilateral radial and brachial pulses, with variable intensity control\nAuscultation of normal and abnormal heart, lung and bowel sounds\nAudible Korotkoff sounds generated with NIBP\nTwo-way communication between manikin and facilitator\nPrerecorded speed and vocal sounds\nInterchangeable genitalia\nUrinary catheterization without fluids\nIV/IO arm and a NIBP/pulse arm\n4 intramuscular injection sites\nArticulating range of motion in hips, knees, ankles, shoulders\nMust be able to be cleaned with PDF Purple top wipes for disinfection.\nHFM needs to be compatible with CAE Maestro software","html":"Sources Sought Notice   HI-FIDELITY MANIKIN\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nResponse Instructions:\nDo not provide more than 8 pages, including cover letter page.\nSubmit your response via email to: barron.long@va.gov\nSubmit your response NLT 12:00 (MST) on Friday, October 3rd 12:00 local mountain time\nMark your response as  Proprietary Information  if the information is considered business sensitive.\nVA has identified the appropriate North American Industry Classification System (NAICS) Code 339112 Surgical and Medical Instrument Manufacturing with a Small Business size of 1000 employees.  Please identify and explain any NAICS codes your company believes would better represent the predominated work included in the attached Statement of Work draft / Salient Characteristics List;\n\nInformation Requested from Industry:\n\nIn response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List.\n\n\nVendor Name:\n\nSAM UEI #:\n\nName of Manufacturer:\n\nManufacturer Address:\n\nManufacturing Country of Origin\nEstimated Delivery Time:\n___________________________________________________\nSAC FSS contract number\n\nVendor Point of Contract (POC) Name\n\nPOC Phone Number:\n\nPOC Email Address:\n\n\n\n\n\n\nSTATEMENT OF WORK\n\nREQUIREMENT \n-What is this requirement for? High fidelity manikin (HFM) for mock code training\n-Reason requirement is needed:\n -Situation-Directive 1177 Cardiopulmonary Resuscitation maintains policy to optimize patient safety for those requiring resuscitation within the Department of VA health care system.  The Resuscitation Education and Innovation (REdI) program is the official VHA national program which provides enterprise-wide oversight and support.   REdI requires a mock code program is implemented across all areas of the VA medical facility\n -What will the period of performance be for this requirement? One time purchase\n -Assessment-HFM is needed to adhere to Directive 1177 and the REdI program by providing training to optimize patient safety\n -Recommendation-Ensure a HFM in working order is available to continue to comply with the Directive and REdI requirements.  Current HFM is at end of life. \n\n-Quantities (equipment only): 1 Manikin\n\nDELIVERY INFORMATION\nMontana VAHCS: Fort Harrison VAMC\n3687 Veteran s Drive, Bldg. 150, room 107 \nFort Harrison, MT 59636\n\n\n\n\n\n\n\n\n\n\n\n\n\nSalient Characteristics\n\nThe High Fidelity Manikin (HFM) needs to demonstrate the following:\nSpontaneous breathing with unilateral and bilateral chest rise and fall.\nAllow for bilateral needle decompressions\nAllow for oral and nasal endotracheal intubation with right main stem detection\nAllow for bilateral needle decompression of lungs\nShow 4-lead and 12-lead cardiac rhythms\nAllow for unilateral blood pressure measurement by auscultation and palpitation\nBilateral carotid and femoral pulses, with variable intensity control\nUnilateral radial and brachial pulses, with variable intensity control\nAuscultation of normal and abnormal heart, lung and bowel sounds\nAudible Korotkoff sounds generated with NIBP\nTwo-way communication between manikin and facilitator\nPrerecorded speed and vocal sounds\nInterchangeable genitalia\nUrinary catheterization without fluids\nIV/IO arm and a NIBP/pulse arm\n4 intramuscular injection sites\nArticulating range of motion in hips, knees, ankles, shoulders\nMust be able to be cleaned with PDF Purple top wipes for disinfection. \nHFM needs to be compatible with CAE Maestro  software","origin":"detail"},"contacts":[{"name":"Barron Long","role":"primary","email":"barron.long@va.gov","phone":"303-712-5741","title":"Contracting Officer"}],"place_of_performance":{"zip":"59636","city":{"code":"28075","name":"Fort Harrison"},"state":{"code":"MT","name":"Montana"},"street":"Department of Veterans Affairs Fort Harrison VAMC","country":{"code":"USA","name":"UNITED STATES"},"street2":"3687 Veterans Drive"},"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"naics_codes":["339112"],"award":{"awardee":{}},"attachments":[{"resource_id":"bfbf0cecd4c343edb2478b44c1878608","name":"36C25925Q0822.docx","kind":"file","mime_type":".docx","size_bytes":28329,"posted_at":"2025-09-24T15:00:59.363Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/bfbf0cecd4c343edb2478b44c1878608/download","mirrored":false}],"awards":[],"related":[{"key":"36C25927Q0059","latest_notice_id":"f35da348ba2e440ca3ee5c48608c0559","title":"S208--Linen Processing, 12/15/2026 to 12/14/2031","solicitation_number":"36C25927Q0059","notice_type":"r","first_type":"r","first_posted":"2026-11-25","last_posted":"2026-11-25","notices":1,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"812320","psc":"S208","set_aside":null,"state":"OK","county":"40101","county_name":"Muskogee County","city":"4050050","city_name":"Muskogee","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"},{"key":"36C25927Q0061","latest_notice_id":"2844a59e27da407db5c5aac404bd35d7","title":"AI tool for Medication Reconciliation and Clinical Review","solicitation_number":"36C25927Q0061","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"541519","psc":"DA10","set_aside":null,"state":"CO","county":"08077","county_name":"Mesa County","city":"0831660","city_name":"Grand Junction","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C25927Q0060","latest_notice_id":"dab1ae13fa4543da8629e3ba28875296","title":"J023-- Transmission Repair/Replacement x2","solicitation_number":"36C25927Q0060","notice_type":"k","first_type":"k","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-12-04T17:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"811111","psc":"J023","set_aside":"SBA","state":"UT","county":"49035","county_name":"Salt Lake County","city":"4967000","city_name":"Salt Lake City","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C25927Q0048","latest_notice_id":"fbc78696b6664ac4b7cf9fa0d88ed616","title":"Radiant Heating Panel Replacement","solicitation_number":"36C25927Q0048","notice_type":"k","first_type":"k","first_posted":"2026-11-04","last_posted":"2026-11-25","notices":4,"due_at":"2026-12-04T19:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"238220","psc":"J045","set_aside":"SBA","state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"},{"key":"36C25927Q0063","latest_notice_id":"3aec52f34d1346bcb89262decf41e0e9","title":"J045--Annual Boiler Maintenance RMR VAMC","solicitation_number":"36C25927Q0063","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-04T21:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"238220","psc":"J045","set_aside":null,"state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open":[{"key":"W911S227U0200","latest_notice_id":"153aef7d00e740188276deb8422a2297","title":"Automated External Defibrillator (AED)","solicitation_number":"W911S227U0200","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T20:15:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:15:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24727Q0119","latest_notice_id":"81776fecabf149c9867d6253acdc2478","title":"Vivarium Tunnel Washer","solicitation_number":"36C24727Q0119","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"339112","psc":"6640","set_aside":null,"state":"GA","county":"13089","county_name":"DeKalb County","city":"1322052","city_name":"Decatur","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C10X27Q0025","latest_notice_id":"8c404062fbbc4212bb93120ad204ee50","title":"6515--NX EQ Microscope, Light, Operating, Hand/Plastic Surgery (VA-27-00017958)","solicitation_number":"36C10X27Q0025","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"}],"similar_open_total":15,"indexable":false}