{"canonical":"https://sealedbidder.com/opportunities/36c25925q0681","key":"36C25925Q0681","url":"https://sealedbidder.com/opportunities/36c25925q0681","title":"6515--436 Fort Harrison VA Medical Center A/B Scanner for Opthalmology","solicitation_number":"36C25925Q0681","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-08-13T18:00:00Z","first_posted":"2025-07-30","last_posted":"2025-07-30","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"339112","psc":"6515","set_aside":null,"place_state":"MT","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"30049","place_county_name":"Lewis and Clark County","place_city":null,"place_city_name":null,"winner":"MELLING LLC","award_amount":null,"publications":[{"notice_id":"48bf656c061f436eb28b3b3399830e10","title":"6515--436 Fort Harrison VA Medical Center A/B Scanner for Opthalmology","solicitation_number":"36C25925Q0681","notice_type":"k","base_type":"k","posted":"2025-07-30","posted_at":"2025-07-30T20:11:15.759Z","due_at":"2025-08-13T18:00:00Z","due_date":"2025-08-13","cancelled":false,"archived":true,"archive_date":"2025-10-12","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/48bf656c061f436eb28b3b3399830e10/view","enriched":true,"history":[{"index":3,"title":"6515--436 Fort Harrison VA Medical Center A/B Scanner for Opthalmology","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-30T20:11:15.759Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"48bf656c061f436eb28b3b3399830e10","solicitation_number":"36C25925Q0681"}]}],"latest_notice_id":"48bf656c061f436eb28b3b3399830e10","first_type":"k","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-07-30","posted_at":"2025-07-30T20:11:15.759Z","created_at":"2025-07-30T20:11:13.525Z","modified_at":"2025-10-13T03:55:46.026Z","response_deadline":{"raw":"2025-08-13T12:00:00-06:00","utc":"2025-08-13T18:00:00Z","date":"2025-08-13","time":"12:00:00","timezone":"America/Denver","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/48bf656c061f436eb28b3b3399830e10/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"6515--436 Fort Harrison VA Medical Center A/B Scanner for Opthalmology","agency":{"office":{"code":"36C259","name":"NETWORK CONTRACT OFFICE 19 (36C259)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"organization_id":"100176750","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-10-12","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--436 Fort Harrison VA Medical Center A/B Scanner for Opthalmology","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-30T20:11:15.759Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"48bf656c061f436eb28b3b3399830e10","solicitation_number":"36C25925Q0681"}],"contacts":[{"name":"Barron Long","role":"primary","email":"barron.long@va.gov","phone":"303-712-5741","title":"Contracting Officer"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"48bf656c061f436eb28b3b3399830e10","lineage_id":"48bf656c061f436eb28b3b3399830e10","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-07T02:04:06.079829448Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"33310f166f3fb45fd5e5c0969f08b69990bca501099e9c646bf083a746ab5efe","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-07T02:04:06.079829448Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Sources Sought Notice   A/B SCANNER FOR OPTHALMALOGY\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nResponse Instructions:\nDo not provide more than 8 pages, including cover letter page.\nSubmit your response via email to: barron.long@va.gov\nSubmit your response NLT 12:00 (MST) on Wednesday, August 13th\nMark your response as  Proprietary Information  if the information is considered business sensitive.\nVA has identified the appropriate North American Industry Classification System (NAICS) Code 339112 Surgical and Medical Instrument Manufacturing with a Small Business size of 1000 employees.  Please identify and explain any NAICS codes your company believes would better represent the predominated work included in the attached Statement of Work draft / Salient Characteristics List;\n\nInformation Requested from Industry:\n\nIn response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List.\n\n\nVendor Name:\n\nSAM UEI #:\n\nName of Manufacturer:\n\nManufacturer Address:\n\nManufacturing Country of Origin\nEstimated Delivery Time:\n___________________________________________________\nSAC FSS contract number\n\nVendor Point of Contract (POC) Name\n\nPOC Phone Number:\n\nPOC Email Address:\n\n\n\n\n\n\nSTATEMENT OF WORK (SOW)\nas of 07/21/2025\n\n\n\n2.  Contract Title.  New A/B Scan for Billings Ophthalmology\n3.  Background.  \nThe A/B Scan for measuring axial length of the eye and thickness of the retinal layers or lesions, in Billings quit working and is beyond end of life so no parts are available for repairs.\n4.  Scope. \n\nProcure a new A/B Scan for Billings Ophthalmology that is on the approved list of equipment for FORUM compatibility as the interface is already in place across VA Montana. \n\n5. Specific Tasks.  \n\nA/B scan instrument MUST be on the approved list of equipment for Forum compatibility   must have an ERA and be Vista Approved\nMust have DICOM compliance capability.  \nA/B scan probes must be detachable so it can be processed by SPS in accordance with our disinfecting policy.\nMust have A-scan and B-scan options for measuring eye length and retinal thickness or lesion thickness.\nDue to space constraints of room equipment will be utilized in, need a single unit with interchangeable probes no larger than 15 x15  footprint.\nDue to limited space constraints and sensitive electrical equipment, must be direct contact A-scan NOT immersion for obtaining readings.\nNeeds foot pedal to obtain readings so do not have to resituate while taking readings.\nMust plug into standard US outlet.\nMust be MADE IN THE USA\nManufacturer must set up equipment and provide instructional training to provider and technicians.\n\n\n Task 1 - Enterprise Management Controls.  \n\nSubtask 1   A/B Scan equipment and software must be compatible with Forum which is in place across VA Montana.  Instrument will be used to take axial length, anterior chamber depth, white to white, and lesion thickness measurements, then transmit those measurements to the VA internal platform Forum where they can be assessed by the doctor.  There is a specific list of approved devices that have been validated through the VistA database for compatibility with Forum.  Any equipment that is not on the list is not guaranteed to work with Forum which is established and utilized throughout VA Montana, and the rigorous testing process to see if a piece of equipment is compatible take almost 12 months.  \n\n\n\nSecurity Requirements\nInterfaces with Forum an internal storage platform that is already in use across VA Montana. \n7.  Place of Performance. \n\nWill be in the Billings VA Ophthalmology Clinic to be used by the ophthalmologist or ophthalmology technician on staff for measurements unable to be obtained by IOL master or OCT or to get an idea of retinal layers when view into eye is obstructed.  \n\n 8.  Delivery Schedule. \n\nContracted vendor will deliver to Billings VA (Benjamin Steele) and coordinate with Biomed for installation in the exam room on a date when the doctor is not seeing patients.  Once the instrument has been set up Biomed with work with Ophthalmology department to schedule a training with the manufacturer to provide education on functionality and performance.  \n\n\nLINE ITEM:\nQTY 1: VUPAD B-SCAN/A-SCAN SYSTEM WITH ULTRASOUND DICOM MODULE","text":"Sources Sought Notice A/B SCANNER FOR OPTHALMALOGY\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nResponse Instructions:\nDo not provide more than 8 pages, including cover letter page.\nSubmit your response via email to: barron.long@va.gov\nSubmit your response NLT 12:00 (MST) on Wednesday, August 13th\nMark your response as Proprietary Information if the information is considered business sensitive.\nVA has identified the appropriate North American Industry Classification System (NAICS) Code 339112 Surgical and Medical Instrument Manufacturing with a Small Business size of 1000 employees. Please identify and explain any NAICS codes your company believes would better represent the predominated work included in the attached Statement of Work draft / Salient Characteristics List;\n\nInformation Requested from Industry:\n\nIn response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List.\n\nVendor Name:\n\nSAM UEI #:\n\nName of Manufacturer:\n\nManufacturer Address:\n\nManufacturing Country of Origin\nEstimated Delivery Time:\n___________________________________________________\nSAC FSS contract number\n\nVendor Point of Contract (POC) Name\n\nPOC Phone Number:\n\nPOC Email Address:\n\nSTATEMENT OF WORK (SOW)\nas of 07/21/2025\n\n2. Contract Title. New A/B Scan for Billings Ophthalmology\n3. Background.\nThe A/B Scan for measuring axial length of the eye and thickness of the retinal layers or lesions, in Billings quit working and is beyond end of life so no parts are available for repairs.\n4. Scope.\n\nProcure a new A/B Scan for Billings Ophthalmology that is on the approved list of equipment for FORUM compatibility as the interface is already in place across VA Montana.\n\n5. Specific Tasks.\n\nA/B scan instrument MUST be on the approved list of equipment for Forum compatibility must have an ERA and be Vista Approved\nMust have DICOM compliance capability.\nA/B scan probes must be detachable so it can be processed by SPS in accordance with our disinfecting policy.\nMust have A-scan and B-scan options for measuring eye length and retinal thickness or lesion thickness.\nDue to space constraints of room equipment will be utilized in, need a single unit with interchangeable probes no larger than 15 x15 footprint.\nDue to limited space constraints and sensitive electrical equipment, must be direct contact A-scan NOT immersion for obtaining readings.\nNeeds foot pedal to obtain readings so do not have to resituate while taking readings.\nMust plug into standard US outlet.\nMust be MADE IN THE USA\nManufacturer must set up equipment and provide instructional training to provider and technicians.\n\nTask 1 - Enterprise Management Controls.\n\nSubtask 1 A/B Scan equipment and software must be compatible with Forum which is in place across VA Montana. Instrument will be used to take axial length, anterior chamber depth, white to white, and lesion thickness measurements, then transmit those measurements to the VA internal platform Forum where they can be assessed by the doctor. There is a specific list of approved devices that have been validated through the VistA database for compatibility with Forum. Any equipment that is not on the list is not guaranteed to work with Forum which is established and utilized throughout VA Montana, and the rigorous testing process to see if a piece of equipment is compatible take almost 12 months.\n\nSecurity Requirements\nInterfaces with Forum an internal storage platform that is already in use across VA Montana.\n7. Place of Performance.\n\nWill be in the Billings VA Ophthalmology Clinic to be used by the ophthalmologist or ophthalmology technician on staff for measurements unable to be obtained by IOL master or OCT or to get an idea of retinal layers when view into eye is obstructed.\n\n8. Delivery Schedule.\n\nContracted vendor will deliver to Billings VA (Benjamin Steele) and coordinate with Biomed for installation in the exam room on a date when the doctor is not seeing patients. Once the instrument has been set up Biomed with work with Ophthalmology department to schedule a training with the manufacturer to provide education on functionality and performance.\n\nLINE ITEM:\nQTY 1: VUPAD B-SCAN/A-SCAN SYSTEM WITH ULTRASOUND DICOM MODULE","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C25925Q0681","place_of_performance":{"zip":"59636","city":{"code":"28075","name":"Fort Harrison"},"state":{"code":"MT","name":"Montana"},"street":"Dept. of Veterans Affairs Fort Harrison VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"3687 Veterans Drive"},"product_service_code":"6515"}],"due_at":"2025-08-13T18:00:00Z","due_date":"2025-08-13","closes_at":"2025-08-13T18:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","state":"MT","county":"30049","county_name":"Lewis and Clark County","city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"CA7CDKQND7U9","amount":null,"linked_awards":1,"cancelled":false,"archived":true,"updated_at":"2026-11-07T02:10:07.957331Z","principal_notice_id":"48bf656c061f436eb28b3b3399830e10","description":{"text":"Sources Sought Notice A/B SCANNER FOR OPTHALMALOGY\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nResponse Instructions:\nDo not provide more than 8 pages, including cover letter page.\nSubmit your response via email to: barron.long@va.gov\nSubmit your response NLT 12:00 (MST) on Wednesday, August 13th\nMark your response as Proprietary Information if the information is considered business sensitive.\nVA has identified the appropriate North American Industry Classification System (NAICS) Code 339112 Surgical and Medical Instrument Manufacturing with a Small Business size of 1000 employees. Please identify and explain any NAICS codes your company believes would better represent the predominated work included in the attached Statement of Work draft / Salient Characteristics List;\n\nInformation Requested from Industry:\n\nIn response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List.\n\nVendor Name:\n\nSAM UEI #:\n\nName of Manufacturer:\n\nManufacturer Address:\n\nManufacturing Country of Origin\nEstimated Delivery Time:\n___________________________________________________\nSAC FSS contract number\n\nVendor Point of Contract (POC) Name\n\nPOC Phone Number:\n\nPOC Email Address:\n\nSTATEMENT OF WORK (SOW)\nas of 07/21/2025\n\n2. Contract Title. New A/B Scan for Billings Ophthalmology\n3. Background.\nThe A/B Scan for measuring axial length of the eye and thickness of the retinal layers or lesions, in Billings quit working and is beyond end of life so no parts are available for repairs.\n4. Scope.\n\nProcure a new A/B Scan for Billings Ophthalmology that is on the approved list of equipment for FORUM compatibility as the interface is already in place across VA Montana.\n\n5. Specific Tasks.\n\nA/B scan instrument MUST be on the approved list of equipment for Forum compatibility must have an ERA and be Vista Approved\nMust have DICOM compliance capability.\nA/B scan probes must be detachable so it can be processed by SPS in accordance with our disinfecting policy.\nMust have A-scan and B-scan options for measuring eye length and retinal thickness or lesion thickness.\nDue to space constraints of room equipment will be utilized in, need a single unit with interchangeable probes no larger than 15 x15 footprint.\nDue to limited space constraints and sensitive electrical equipment, must be direct contact A-scan NOT immersion for obtaining readings.\nNeeds foot pedal to obtain readings so do not have to resituate while taking readings.\nMust plug into standard US outlet.\nMust be MADE IN THE USA\nManufacturer must set up equipment and provide instructional training to provider and technicians.\n\nTask 1 - Enterprise Management Controls.\n\nSubtask 1 A/B Scan equipment and software must be compatible with Forum which is in place across VA Montana. Instrument will be used to take axial length, anterior chamber depth, white to white, and lesion thickness measurements, then transmit those measurements to the VA internal platform Forum where they can be assessed by the doctor. There is a specific list of approved devices that have been validated through the VistA database for compatibility with Forum. Any equipment that is not on the list is not guaranteed to work with Forum which is established and utilized throughout VA Montana, and the rigorous testing process to see if a piece of equipment is compatible take almost 12 months.\n\nSecurity Requirements\nInterfaces with Forum an internal storage platform that is already in use across VA Montana.\n7. Place of Performance.\n\nWill be in the Billings VA Ophthalmology Clinic to be used by the ophthalmologist or ophthalmology technician on staff for measurements unable to be obtained by IOL master or OCT or to get an idea of retinal layers when view into eye is obstructed.\n\n8. Delivery Schedule.\n\nContracted vendor will deliver to Billings VA (Benjamin Steele) and coordinate with Biomed for installation in the exam room on a date when the doctor is not seeing patients. Once the instrument has been set up Biomed with work with Ophthalmology department to schedule a training with the manufacturer to provide education on functionality and performance.\n\nLINE ITEM:\nQTY 1: VUPAD B-SCAN/A-SCAN SYSTEM WITH ULTRASOUND DICOM MODULE","html":"Sources Sought Notice   A/B SCANNER FOR OPTHALMALOGY\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nResponse Instructions:\nDo not provide more than 8 pages, including cover letter page.\nSubmit your response via email to: barron.long@va.gov\nSubmit your response NLT 12:00 (MST) on Wednesday, August 13th\nMark your response as  Proprietary Information  if the information is considered business sensitive.\nVA has identified the appropriate North American Industry Classification System (NAICS) Code 339112 Surgical and Medical Instrument Manufacturing with a Small Business size of 1000 employees.  Please identify and explain any NAICS codes your company believes would better represent the predominated work included in the attached Statement of Work draft / Salient Characteristics List;\n\nInformation Requested from Industry:\n\nIn response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List.\n\n\nVendor Name:\n\nSAM UEI #:\n\nName of Manufacturer:\n\nManufacturer Address:\n\nManufacturing Country of Origin\nEstimated Delivery Time:\n___________________________________________________\nSAC FSS contract number\n\nVendor Point of Contract (POC) Name\n\nPOC Phone Number:\n\nPOC Email Address:\n\n\n\n\n\n\nSTATEMENT OF WORK (SOW)\nas of 07/21/2025\n\n\n\n2.  Contract Title.  New A/B Scan for Billings Ophthalmology\n3.  Background.  \nThe A/B Scan for measuring axial length of the eye and thickness of the retinal layers or lesions, in Billings quit working and is beyond end of life so no parts are available for repairs.\n4.  Scope. \n\nProcure a new A/B Scan for Billings Ophthalmology that is on the approved list of equipment for FORUM compatibility as the interface is already in place across VA Montana. \n\n5. Specific Tasks.  \n\nA/B scan instrument MUST be on the approved list of equipment for Forum compatibility   must have an ERA and be Vista Approved\nMust have DICOM compliance capability.  \nA/B scan probes must be detachable so it can be processed by SPS in accordance with our disinfecting policy.\nMust have A-scan and B-scan options for measuring eye length and retinal thickness or lesion thickness.\nDue to space constraints of room equipment will be utilized in, need a single unit with interchangeable probes no larger than 15 x15  footprint.\nDue to limited space constraints and sensitive electrical equipment, must be direct contact A-scan NOT immersion for obtaining readings.\nNeeds foot pedal to obtain readings so do not have to resituate while taking readings.\nMust plug into standard US outlet.\nMust be MADE IN THE USA\nManufacturer must set up equipment and provide instructional training to provider and technicians.\n\n\n Task 1 - Enterprise Management Controls.  \n\nSubtask 1   A/B Scan equipment and software must be compatible with Forum which is in place across VA Montana.  Instrument will be used to take axial length, anterior chamber depth, white to white, and lesion thickness measurements, then transmit those measurements to the VA internal platform Forum where they can be assessed by the doctor.  There is a specific list of approved devices that have been validated through the VistA database for compatibility with Forum.  Any equipment that is not on the list is not guaranteed to work with Forum which is established and utilized throughout VA Montana, and the rigorous testing process to see if a piece of equipment is compatible take almost 12 months.  \n\n\n\nSecurity Requirements\nInterfaces with Forum an internal storage platform that is already in use across VA Montana. \n7.  Place of Performance. \n\nWill be in the Billings VA Ophthalmology Clinic to be used by the ophthalmologist or ophthalmology technician on staff for measurements unable to be obtained by IOL master or OCT or to get an idea of retinal layers when view into eye is obstructed.  \n\n 8.  Delivery Schedule. \n\nContracted vendor will deliver to Billings VA (Benjamin Steele) and coordinate with Biomed for installation in the exam room on a date when the doctor is not seeing patients.  Once the instrument has been set up Biomed with work with Ophthalmology department to schedule a training with the manufacturer to provide education on functionality and performance.  \n\n\nLINE ITEM:\nQTY 1: VUPAD B-SCAN/A-SCAN SYSTEM WITH ULTRASOUND DICOM MODULE","origin":"detail"},"contacts":[{"name":"Barron Long","role":"primary","email":"barron.long@va.gov","phone":"303-712-5741","title":"Contracting Officer"}],"place_of_performance":{"zip":"59636","city":{"code":"28075","name":"Fort Harrison"},"state":{"code":"MT","name":"Montana"},"street":"Dept. of Veterans Affairs Fort Harrison VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"3687 Veterans Drive"},"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"naics_codes":["339112"],"award":{"awardee":{}},"attachments":[{"resource_id":"b0e1be52db8145d5bfefc8fc5d47bca4","name":"36C25925Q0681.docx","kind":"file","mime_type":".docx","size_bytes":20753,"posted_at":"2025-07-30T20:11:15.759Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/b0e1be52db8145d5bfefc8fc5d47bca4/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C25925P1121_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C25925P1121_3600_-NONE-_-NONE-/","piid":"36C25925P1121","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"CA7CDKQND7U9","recipient_name":"MELLING LLC","recipient_uei":"CA7CDKQND7U9","recipient_cage":"6XD62","recipient_city":"ALEXANDRIA","recipient_state":"VA","sub_name":"Department of Veterans Affairs","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","office_key":"o-36C259","first_action_date":"2025-09-16","last_action_date":"2025-09-16","actions":1,"obligated":"16816.79","current_total_value":"16816.79","potential_total_value":"16816.79","naics":"339112","psc":"6515","extent_competed":"COMPETED UNDER SAP","set_aside":"SMALL BUSINESS SET ASIDE - TOTAL","offers_received":2,"description":"A/B SCANNING SYSTEM","method":"solicitation","confidence":"high","evidence":["solicitation number 36C25925Q0681 equals the FPDS solicitation identifier","same awarding office 36C259"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C25927Q0059","latest_notice_id":"f35da348ba2e440ca3ee5c48608c0559","title":"S208--Linen Processing, 12/15/2026 to 12/14/2031","solicitation_number":"36C25927Q0059","notice_type":"r","first_type":"r","first_posted":"2026-11-25","last_posted":"2026-11-25","notices":1,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"812320","psc":"S208","set_aside":null,"state":"OK","county":"40101","county_name":"Muskogee County","city":"4050050","city_name":"Muskogee","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"},{"key":"36C25927Q0061","latest_notice_id":"2844a59e27da407db5c5aac404bd35d7","title":"AI tool for Medication Reconciliation and Clinical Review","solicitation_number":"36C25927Q0061","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"541519","psc":"DA10","set_aside":null,"state":"CO","county":"08077","county_name":"Mesa County","city":"0831660","city_name":"Grand Junction","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C25927Q0060","latest_notice_id":"dab1ae13fa4543da8629e3ba28875296","title":"J023-- Transmission Repair/Replacement x2","solicitation_number":"36C25927Q0060","notice_type":"k","first_type":"k","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-12-04T17:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"811111","psc":"J023","set_aside":"SBA","state":"UT","county":"49035","county_name":"Salt Lake County","city":"4967000","city_name":"Salt Lake City","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C25927Q0048","latest_notice_id":"fbc78696b6664ac4b7cf9fa0d88ed616","title":"Radiant Heating Panel Replacement","solicitation_number":"36C25927Q0048","notice_type":"k","first_type":"k","first_posted":"2026-11-04","last_posted":"2026-11-25","notices":4,"due_at":"2026-12-04T19:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"238220","psc":"J045","set_aside":"SBA","state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"},{"key":"36C25927Q0063","latest_notice_id":"3aec52f34d1346bcb89262decf41e0e9","title":"J045--Annual Boiler Maintenance RMR VAMC","solicitation_number":"36C25927Q0063","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-04T21:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"238220","psc":"J045","set_aside":null,"state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open":[{"key":"W911S227U0200","latest_notice_id":"153aef7d00e740188276deb8422a2297","title":"Automated External Defibrillator (AED)","solicitation_number":"W911S227U0200","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T20:15:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:15:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24727Q0119","latest_notice_id":"81776fecabf149c9867d6253acdc2478","title":"Vivarium Tunnel Washer","solicitation_number":"36C24727Q0119","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"339112","psc":"6640","set_aside":null,"state":"GA","county":"13089","county_name":"DeKalb County","city":"1322052","city_name":"Decatur","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C10X27Q0025","latest_notice_id":"8c404062fbbc4212bb93120ad204ee50","title":"6515--NX EQ Microscope, Light, Operating, Hand/Plastic Surgery (VA-27-00017958)","solicitation_number":"36C10X27Q0025","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"}],"similar_open_total":15,"indexable":false}