{"canonical":"https://sealedbidder.com/opportunities/36c25925q0638","key":"36C25925Q0638","url":"https://sealedbidder.com/opportunities/36c25925q0638","title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","solicitation_number":"36C25925Q0638","notice_type":"o","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-08-18T15:00:00Z","first_posted":"2025-07-17","last_posted":"2025-08-12","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"238210","psc":"Z2DZ","set_aside":"SDVOSBC","place_state":"OK","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"40109","place_county_name":"Oklahoma County","place_city":"4055000","place_city_name":"Oklahoma City","winner":"VETERANS PRE-CONSTRUCTION & VISUAL SOLUTIONS, LLC","award_amount":null,"publications":[{"notice_id":"64d3bbac9f23466599143f8fc586d053","title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","solicitation_number":"36C25925Q0638","notice_type":"o","base_type":"p","posted":"2025-07-17","posted_at":"2025-07-17T21:17:01.710Z","due_at":"2025-08-18T15:00:00Z","due_date":"2025-08-18","cancelled":false,"archived":true,"archive_date":"2025-08-23","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/64d3bbac9f23466599143f8fc586d053/view","enriched":true,"history":[{"index":7,"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-12T17:24:14.930Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"454433d5b5f54b49b33c44f5799b1a87","solicitation_number":"36C25925Q0638","parent_opportunity_id":"64d3bbac9f23466599143f8fc586d053"},{"index":5,"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-26T18:38:13.333Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"16a96918c8ae4eb395b5d5fd35527d95","solicitation_number":"36C25925Q0638","parent_opportunity_id":"64d3bbac9f23466599143f8fc586d053"},{"index":4,"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-17T21:15:25.968Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"a881fa06a4354ec3b5ec507419740010","solicitation_number":"36C25925Q0638"},{"index":2,"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-17T21:17:01.710Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"64d3bbac9f23466599143f8fc586d053","solicitation_number":"36C25925Q0638","related_opportunity_id":"a881fa06a4354ec3b5ec507419740010"}]},{"notice_id":"a881fa06a4354ec3b5ec507419740010","title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","solicitation_number":"36C25925Q0638","notice_type":"p","base_type":"p","posted":"2025-07-17","posted_at":"2025-07-17T21:15:25.968Z","due_at":"2025-07-17T22:00:00Z","due_date":"2025-07-17","cancelled":false,"archived":true,"archive_date":"2025-07-22","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/a881fa06a4354ec3b5ec507419740010/view","enriched":true,"history":[{"index":4,"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-17T21:15:25.968Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"a881fa06a4354ec3b5ec507419740010","solicitation_number":"36C25925Q0638"},{"index":2,"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-17T21:17:01.710Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"64d3bbac9f23466599143f8fc586d053","solicitation_number":"36C25925Q0638","related_opportunity_id":"a881fa06a4354ec3b5ec507419740010"}]},{"notice_id":"16a96918c8ae4eb395b5d5fd35527d95","title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","solicitation_number":"36C25925Q0638","notice_type":"o","base_type":"o","posted":"2025-07-26","posted_at":"2025-07-26T18:38:13.333Z","due_at":"2025-08-18T15:00:00Z","due_date":"2025-08-18","cancelled":false,"archived":true,"archive_date":"2025-09-17","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/16a96918c8ae4eb395b5d5fd35527d95/view","enriched":true,"history":[{"index":4,"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-12T17:24:14.930Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"454433d5b5f54b49b33c44f5799b1a87","solicitation_number":"36C25925Q0638","parent_opportunity_id":"64d3bbac9f23466599143f8fc586d053"},{"index":2,"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-26T18:38:13.333Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"16a96918c8ae4eb395b5d5fd35527d95","solicitation_number":"36C25925Q0638","parent_opportunity_id":"64d3bbac9f23466599143f8fc586d053"},{"index":1,"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-17T21:17:01.710Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"64d3bbac9f23466599143f8fc586d053","solicitation_number":"36C25925Q0638","related_opportunity_id":"a881fa06a4354ec3b5ec507419740010"}]},{"notice_id":"454433d5b5f54b49b33c44f5799b1a87","title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","solicitation_number":"36C25925Q0638","notice_type":"o","base_type":"o","posted":"2025-08-12","posted_at":"2025-08-12T17:24:14.930Z","due_at":"2025-08-18T15:00:00Z","due_date":"2025-08-18","cancelled":false,"archived":true,"archive_date":"2025-09-17","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/454433d5b5f54b49b33c44f5799b1a87/view","enriched":true,"history":[{"index":4,"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-12T17:24:14.930Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"454433d5b5f54b49b33c44f5799b1a87","solicitation_number":"36C25925Q0638","parent_opportunity_id":"64d3bbac9f23466599143f8fc586d053"},{"index":2,"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-26T18:38:13.333Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"16a96918c8ae4eb395b5d5fd35527d95","solicitation_number":"36C25925Q0638","parent_opportunity_id":"64d3bbac9f23466599143f8fc586d053"},{"index":1,"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-17T21:17:01.710Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"64d3bbac9f23466599143f8fc586d053","solicitation_number":"36C25925Q0638","related_opportunity_id":"a881fa06a4354ec3b5ec507419740010"}]}],"latest_notice_id":"454433d5b5f54b49b33c44f5799b1a87","first_type":"o","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-07-17","posted_at":"2025-07-17T21:17:01.710Z","created_at":"2025-07-17T21:16:53.947Z","modified_at":"2025-09-18T03:55:51.428Z","response_deadline":{"raw":"2025-08-18T10:00:00-05:00","utc":"2025-08-18T15:00:00Z","date":"2025-08-18","time":"10:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/64d3bbac9f23466599143f8fc586d053/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","agency":{"office":{"code":"36C259","name":"NETWORK CONTRACT OFFICE 19 (36C259)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"organization_id":"100176750","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-08-23","archive_type":"auto_custom"},"history":[{"index":7,"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-12T17:24:14.930Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"454433d5b5f54b49b33c44f5799b1a87","solicitation_number":"36C25925Q0638","parent_opportunity_id":"64d3bbac9f23466599143f8fc586d053"},{"index":5,"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-26T18:38:13.333Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"16a96918c8ae4eb395b5d5fd35527d95","solicitation_number":"36C25925Q0638","parent_opportunity_id":"64d3bbac9f23466599143f8fc586d053"},{"index":4,"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-17T21:15:25.968Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"a881fa06a4354ec3b5ec507419740010","solicitation_number":"36C25925Q0638"},{"index":2,"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-17T21:17:01.710Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"64d3bbac9f23466599143f8fc586d053","solicitation_number":"36C25925Q0638","related_opportunity_id":"a881fa06a4354ec3b5ec507419740010"}],"contacts":[{"name":"Frances Basham (CO)","role":"primary","email":"Frances.Basham@va.gov","title":"Contracting Specialist"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"64d3bbac9f23466599143f8fc586d053","lineage_id":"64d3bbac9f23466599143f8fc586d053","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-09T03:12:39.100442946Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"698837ac73a5fcb843b7885074b94daf8834b805ea80de508b5256edd175966a","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-09T03:12:39.100442946Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"REQUEST FOR QUOTE (RFQ) 36C25925Q0638","text":"REQUEST FOR QUOTE (RFQ) 36C25925Q0638","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C25925Q0638","product_service_code":"Z2DZ"},{"award":{"awardee":{}},"dates":{"posted":"2025-07-17","posted_at":"2025-07-17T21:15:25.968Z","created_at":"2025-07-17T21:15:23.731Z","modified_at":"2025-07-22T04:00:32.826Z","response_deadline":{"raw":"2025-07-17T17:00:00-05:00","utc":"2025-07-17T22:00:00Z","date":"2025-07-17","time":"17:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/a881fa06a4354ec3b5ec507419740010/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","agency":{"office":{"code":"36C259","name":"NETWORK CONTRACT OFFICE 19 (36C259)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"organization_id":"100176750","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-07-22","archive_type":"auto_custom"},"history":[{"index":4,"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-17T21:15:25.968Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"a881fa06a4354ec3b5ec507419740010","solicitation_number":"36C25925Q0638"},{"index":2,"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-17T21:17:01.710Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"64d3bbac9f23466599143f8fc586d053","solicitation_number":"36C25925Q0638","related_opportunity_id":"a881fa06a4354ec3b5ec507419740010"}],"contacts":[{"name":"Frankie Basham","role":"primary","email":"frances.basham@va.gov","phone":"918-577-3923","title":"Contracting Officer"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"a881fa06a4354ec3b5ec507419740010","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"64d3bbac9f23466599143f8fc586d053","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-09T03:32:46.020472006Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"47d5e421b557dae0f78d907170de9be0180a562889989de85859e2b170447585","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-09T03:32:46.020472006Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Original Sources Sought Notice Posted 07/01/2025 36C25925R0090","text":"Original Sources Sought Notice Posted 07/01/2025 36C25925R0090","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"36C25925Q0638","place_of_performance":{"zip":"73104","city":{"code":"55000","name":"Oklahoma City"},"state":{"code":"OK","name":"Oklahoma"},"street":"Department of Veterans Affairs Oklahoma City VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"921 NE 13th St."},"product_service_code":"Z2DZ"},{"award":{"awardee":{}},"dates":{"posted":"2025-07-26","posted_at":"2025-07-26T18:38:13.333Z","created_at":"2025-07-26T18:37:44.385Z","modified_at":"2025-09-18T03:55:51.428Z","response_deadline":{"raw":"2025-08-18T10:00:00-05:00","utc":"2025-08-18T15:00:00Z","date":"2025-08-18","time":"10:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/16a96918c8ae4eb395b5d5fd35527d95/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","agency":{"office":{"code":"36C259","name":"NETWORK CONTRACT OFFICE 19 (36C259)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"organization_id":"100176750","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-09-17","archive_type":"auto_custom"},"history":[{"index":4,"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-12T17:24:14.930Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"454433d5b5f54b49b33c44f5799b1a87","solicitation_number":"36C25925Q0638","parent_opportunity_id":"64d3bbac9f23466599143f8fc586d053"},{"index":2,"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-26T18:38:13.333Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"16a96918c8ae4eb395b5d5fd35527d95","solicitation_number":"36C25925Q0638","parent_opportunity_id":"64d3bbac9f23466599143f8fc586d053"},{"index":1,"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-17T21:17:01.710Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"64d3bbac9f23466599143f8fc586d053","solicitation_number":"36C25925Q0638","related_opportunity_id":"a881fa06a4354ec3b5ec507419740010"}],"contacts":[{"name":"Frances Basham (CO)","role":"primary","email":"Frances.Basham@va.gov","title":"Contracting Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"16a96918c8ae4eb395b5d5fd35527d95","lineage_id":"64d3bbac9f23466599143f8fc586d053","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-07T04:29:42.969621356Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"2aa389c44e13d583d745ee9f29a99c2cc0904faa4853dc12e217cb9b354da076","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-07T04:29:42.969621356Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"36C25925Q0638 0001","text":"36C25925Q0638 0001","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C25925Q0638","product_service_code":"Z2DZ"},{"award":{"awardee":{}},"dates":{"posted":"2025-08-12","posted_at":"2025-08-12T17:24:14.930Z","created_at":"2025-08-12T17:24:12.735Z","modified_at":"2025-09-18T03:55:51.428Z","response_deadline":{"raw":"2025-08-18T10:00:00-05:00","utc":"2025-08-18T15:00:00Z","date":"2025-08-18","time":"10:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/454433d5b5f54b49b33c44f5799b1a87/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","agency":{"office":{"code":"36C259","name":"NETWORK CONTRACT OFFICE 19 (36C259)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"organization_id":"100176750","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-09-17","archive_type":"auto_custom"},"history":[{"index":4,"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-12T17:24:14.930Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"454433d5b5f54b49b33c44f5799b1a87","solicitation_number":"36C25925Q0638","parent_opportunity_id":"64d3bbac9f23466599143f8fc586d053"},{"index":2,"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-26T18:38:13.333Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"16a96918c8ae4eb395b5d5fd35527d95","solicitation_number":"36C25925Q0638","parent_opportunity_id":"64d3bbac9f23466599143f8fc586d053"},{"index":1,"title":"Z2DZ--Refeed Electrical from Generator Room to ATS# 3","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-17T21:17:01.710Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"64d3bbac9f23466599143f8fc586d053","solicitation_number":"36C25925Q0638","related_opportunity_id":"a881fa06a4354ec3b5ec507419740010"}],"contacts":[{"name":"Frances Basham (CO)","role":"primary","email":"Frances.Basham@va.gov","title":"Contracting Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"454433d5b5f54b49b33c44f5799b1a87","lineage_id":"64d3bbac9f23466599143f8fc586d053","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-04T02:53:02.722576858Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"8f35a989ade680ef7023b502c85116736bd4394de1b0450c692356713e1a88af","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-04T02:53:02.722576858Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"RFQ 36C25925Q0638 \nRefeed Electrical from Generator Room to ATS #3\nVendor Questions and VA answers in red\n\nCONTRACTOR Q&As #1 \n\n\nQuestion No. 1: How many days' notice do we need to provide to access the two ER rooms and pipe out of both?\n\nAnswer No. 1: Please provide an overall schedule to include the days that you will need access to the rooms as a submittal prior to start of work\n\nQuestion No. 2: How long can each ER be shut down? And can both be shut down simultaneously, or will they need to be phased down?\n\nAnswer No. 2: Please provide an overall schedule to include the days that you will need access to the rooms as a submittal prior to start of work\n\nQuestion No. 3: Is there a way to coordinate access to the 2 ER Rooms in the same day, shut down the ATS 3, which powers all or most of the hospitals MRI machines, and Panel EGR to tie it all in, in the same week and shut down ATS#3 and the panel feeding it, all in the same week?\n\nAnswer No. 3: Part 1: both ER rooms would be able to be closed at the same time, in doing so a barrier would have to be placed at the entrances, as only one tile can be out at a time otherwise.\nPart 2: ATS-3 is critical and down time is limited to four hours in total, it can not be down for a week.\n\nQuestion No. 4: What are the hours we can work, without noise affecting patients with drilling through concrete walls?\n\nAnswer No. 4: There is no best time to work.Â  Patient occupancy fluctuates.  COR work hours are 7:00am to 1530pm.\n\nQuestion No. 5: What are the busiest days for MRIS?\n\nAnswer No. 5: It varies, as it supports our emergency patients as well as regularly scheduled patients, two weeks  notice and coordination will ensure goal is met for outage.\n\nQuestion No. 6: How long can we shut MRIS down?\n\nAnswer No. 6: No more than 4 hours.  Provide schedule of work \n\nQuestion No. 7: Do we need to shut down the Panel EGP, which supplies ATS #3 and features a 225 amp breaker, in order to work on it, or can we work on it while it's live?\n\nAnswer No. 7: Panel EGP is only energized when the generator is running, there will be no problem in shutting the main breaker off, located left of the panel in generator control gear, as long as electrical staff is made aware at the time, no notice would be required for this portion of the project.\n\n\nQuestion No. 8. Please confirm award contractor will have access to the emergency room during construction.\n\nAnswer No. 8: Yes, the contractor will have access to the emergency room, however, the COR will have to badge the contractors in\n\nQuestion No. 9: Since construction will be performed in an active emergency room, will an ICRA plan be provided to all bidders?  \n\nAnswer No. 9: Yes an ICRA will be provided to all bidders \n\nQuestion No. 10: Can the VA specify conduit and wire size/type that needs to be installed?\n\nAnswer No. 10: 4) 4/0s 1) #4 ground, in a 2 1/2'  or 3  conduit, contractor s choice.\n\nQuestion No 11: Can an alternate route be considered? Outside above the canopyÂ walkway possibly? This would keep us from having to go through ER areas. \n\nAnswer No. 11: Conduit needs to be ran with existing conduits, everything currently ran on the outside is for temporary equipment only, permanent utilities need to be physically secured and away from damage.\n\nQuestion No. 12: Does the new feeder need to be in place and ready to terminate before we can demo the old feeder? Or can we demo old feeder as we install new feeder?\n\nAnswer No. 12: Yes, new feeder needs to be in place prior to demo of existing feeder, providing continuity of backup generator feed serving critical loads and patients.\n\nQuestion No. 13: Please confirm if we can do all of the install during normal working hours.\n\nAnswer No. 13: Normal business hours would be best as this is an emergency room, which never shuts down.","text":"RFQ 36C25925Q0638\nRefeed Electrical from Generator Room to ATS #3\nVendor Questions and VA answers in red\n\nCONTRACTOR Q&As #1\n\nQuestion No. 1: How many days' notice do we need to provide to access the two ER rooms and pipe out of both?\n\nAnswer No. 1: Please provide an overall schedule to include the days that you will need access to the rooms as a submittal prior to start of work\n\nQuestion No. 2: How long can each ER be shut down? And can both be shut down simultaneously, or will they need to be phased down?\n\nAnswer No. 2: Please provide an overall schedule to include the days that you will need access to the rooms as a submittal prior to start of work\n\nQuestion No. 3: Is there a way to coordinate access to the 2 ER Rooms in the same day, shut down the ATS 3, which powers all or most of the hospitals MRI machines, and Panel EGR to tie it all in, in the same week and shut down ATS#3 and the panel feeding it, all in the same week?\n\nAnswer No. 3: Part 1: both ER rooms would be able to be closed at the same time, in doing so a barrier would have to be placed at the entrances, as only one tile can be out at a time otherwise.\nPart 2: ATS-3 is critical and down time is limited to four hours in total, it can not be down for a week.\n\nQuestion No. 4: What are the hours we can work, without noise affecting patients with drilling through concrete walls?\n\nAnswer No. 4: There is no best time to work.Â Patient occupancy fluctuates. COR work hours are 7:00am to 1530pm.\n\nQuestion No. 5: What are the busiest days for MRIS?\n\nAnswer No. 5: It varies, as it supports our emergency patients as well as regularly scheduled patients, two weeks notice and coordination will ensure goal is met for outage.\n\nQuestion No. 6: How long can we shut MRIS down?\n\nAnswer No. 6: No more than 4 hours. Provide schedule of work\n\nQuestion No. 7: Do we need to shut down the Panel EGP, which supplies ATS #3 and features a 225 amp breaker, in order to work on it, or can we work on it while it's live?\n\nAnswer No. 7: Panel EGP is only energized when the generator is running, there will be no problem in shutting the main breaker off, located left of the panel in generator control gear, as long as electrical staff is made aware at the time, no notice would be required for this portion of the project.\n\nQuestion No. 8. Please confirm award contractor will have access to the emergency room during construction.\n\nAnswer No. 8: Yes, the contractor will have access to the emergency room, however, the COR will have to badge the contractors in\n\nQuestion No. 9: Since construction will be performed in an active emergency room, will an ICRA plan be provided to all bidders?\n\nAnswer No. 9: Yes an ICRA will be provided to all bidders\n\nQuestion No. 10: Can the VA specify conduit and wire size/type that needs to be installed?\n\nAnswer No. 10: 4) 4/0s 1) #4 ground, in a 2 1/2' or 3 conduit, contractor s choice.\n\nQuestion No 11: Can an alternate route be considered? Outside above the canopyÂ walkway possibly? This would keep us from having to go through ER areas.\n\nAnswer No. 11: Conduit needs to be ran with existing conduits, everything currently ran on the outside is for temporary equipment only, permanent utilities need to be physically secured and away from damage.\n\nQuestion No. 12: Does the new feeder need to be in place and ready to terminate before we can demo the old feeder? Or can we demo old feeder as we install new feeder?\n\nAnswer No. 12: Yes, new feeder needs to be in place prior to demo of existing feeder, providing continuity of backup generator feed serving critical loads and patients.\n\nQuestion No. 13: Please confirm if we can do all of the install during normal working hours.\n\nAnswer No. 13: Normal business hours would be best as this is an emergency room, which never shuts down.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C25925Q0638","product_service_code":"Z2DZ"}],"due_at":"2025-08-18T15:00:00Z","due_date":"2025-08-18","closes_at":"2025-08-18T15:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","state":"OK","county":"40109","county_name":"Oklahoma County","city":"4055000","city_name":"Oklahoma City","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"FAPZQ1BR9L58","amount":null,"linked_awards":4,"cancelled":false,"archived":true,"updated_at":"2026-11-04T03:30:22.940331Z","principal_notice_id":"454433d5b5f54b49b33c44f5799b1a87","description":{"text":"RFQ 36C25925Q0638\nRefeed Electrical from Generator Room to ATS #3\nVendor Questions and VA answers in red\n\nCONTRACTOR Q&As #1\n\nQuestion No. 1: How many days' notice do we need to provide to access the two ER rooms and pipe out of both?\n\nAnswer No. 1: Please provide an overall schedule to include the days that you will need access to the rooms as a submittal prior to start of work\n\nQuestion No. 2: How long can each ER be shut down? And can both be shut down simultaneously, or will they need to be phased down?\n\nAnswer No. 2: Please provide an overall schedule to include the days that you will need access to the rooms as a submittal prior to start of work\n\nQuestion No. 3: Is there a way to coordinate access to the 2 ER Rooms in the same day, shut down the ATS 3, which powers all or most of the hospitals MRI machines, and Panel EGR to tie it all in, in the same week and shut down ATS#3 and the panel feeding it, all in the same week?\n\nAnswer No. 3: Part 1: both ER rooms would be able to be closed at the same time, in doing so a barrier would have to be placed at the entrances, as only one tile can be out at a time otherwise.\nPart 2: ATS-3 is critical and down time is limited to four hours in total, it can not be down for a week.\n\nQuestion No. 4: What are the hours we can work, without noise affecting patients with drilling through concrete walls?\n\nAnswer No. 4: There is no best time to work.Â Patient occupancy fluctuates. COR work hours are 7:00am to 1530pm.\n\nQuestion No. 5: What are the busiest days for MRIS?\n\nAnswer No. 5: It varies, as it supports our emergency patients as well as regularly scheduled patients, two weeks notice and coordination will ensure goal is met for outage.\n\nQuestion No. 6: How long can we shut MRIS down?\n\nAnswer No. 6: No more than 4 hours. Provide schedule of work\n\nQuestion No. 7: Do we need to shut down the Panel EGP, which supplies ATS #3 and features a 225 amp breaker, in order to work on it, or can we work on it while it's live?\n\nAnswer No. 7: Panel EGP is only energized when the generator is running, there will be no problem in shutting the main breaker off, located left of the panel in generator control gear, as long as electrical staff is made aware at the time, no notice would be required for this portion of the project.\n\nQuestion No. 8. Please confirm award contractor will have access to the emergency room during construction.\n\nAnswer No. 8: Yes, the contractor will have access to the emergency room, however, the COR will have to badge the contractors in\n\nQuestion No. 9: Since construction will be performed in an active emergency room, will an ICRA plan be provided to all bidders?\n\nAnswer No. 9: Yes an ICRA will be provided to all bidders\n\nQuestion No. 10: Can the VA specify conduit and wire size/type that needs to be installed?\n\nAnswer No. 10: 4) 4/0s 1) #4 ground, in a 2 1/2' or 3 conduit, contractor s choice.\n\nQuestion No 11: Can an alternate route be considered? Outside above the canopyÂ walkway possibly? This would keep us from having to go through ER areas.\n\nAnswer No. 11: Conduit needs to be ran with existing conduits, everything currently ran on the outside is for temporary equipment only, permanent utilities need to be physically secured and away from damage.\n\nQuestion No. 12: Does the new feeder need to be in place and ready to terminate before we can demo the old feeder? Or can we demo old feeder as we install new feeder?\n\nAnswer No. 12: Yes, new feeder needs to be in place prior to demo of existing feeder, providing continuity of backup generator feed serving critical loads and patients.\n\nQuestion No. 13: Please confirm if we can do all of the install during normal working hours.\n\nAnswer No. 13: Normal business hours would be best as this is an emergency room, which never shuts down.","html":"RFQ 36C25925Q0638 \nRefeed Electrical from Generator Room to ATS #3\nVendor Questions and VA answers in red\n\nCONTRACTOR Q&As #1 \n\n\nQuestion No. 1: How many days' notice do we need to provide to access the two ER rooms and pipe out of both?\n\nAnswer No. 1: Please provide an overall schedule to include the days that you will need access to the rooms as a submittal prior to start of work\n\nQuestion No. 2: How long can each ER be shut down? And can both be shut down simultaneously, or will they need to be phased down?\n\nAnswer No. 2: Please provide an overall schedule to include the days that you will need access to the rooms as a submittal prior to start of work\n\nQuestion No. 3: Is there a way to coordinate access to the 2 ER Rooms in the same day, shut down the ATS 3, which powers all or most of the hospitals MRI machines, and Panel EGR to tie it all in, in the same week and shut down ATS#3 and the panel feeding it, all in the same week?\n\nAnswer No. 3: Part 1: both ER rooms would be able to be closed at the same time, in doing so a barrier would have to be placed at the entrances, as only one tile can be out at a time otherwise.\nPart 2: ATS-3 is critical and down time is limited to four hours in total, it can not be down for a week.\n\nQuestion No. 4: What are the hours we can work, without noise affecting patients with drilling through concrete walls?\n\nAnswer No. 4: There is no best time to work.Â  Patient occupancy fluctuates.  COR work hours are 7:00am to 1530pm.\n\nQuestion No. 5: What are the busiest days for MRIS?\n\nAnswer No. 5: It varies, as it supports our emergency patients as well as regularly scheduled patients, two weeks  notice and coordination will ensure goal is met for outage.\n\nQuestion No. 6: How long can we shut MRIS down?\n\nAnswer No. 6: No more than 4 hours.  Provide schedule of work \n\nQuestion No. 7: Do we need to shut down the Panel EGP, which supplies ATS #3 and features a 225 amp breaker, in order to work on it, or can we work on it while it's live?\n\nAnswer No. 7: Panel EGP is only energized when the generator is running, there will be no problem in shutting the main breaker off, located left of the panel in generator control gear, as long as electrical staff is made aware at the time, no notice would be required for this portion of the project.\n\n\nQuestion No. 8. Please confirm award contractor will have access to the emergency room during construction.\n\nAnswer No. 8: Yes, the contractor will have access to the emergency room, however, the COR will have to badge the contractors in\n\nQuestion No. 9: Since construction will be performed in an active emergency room, will an ICRA plan be provided to all bidders?  \n\nAnswer No. 9: Yes an ICRA will be provided to all bidders \n\nQuestion No. 10: Can the VA specify conduit and wire size/type that needs to be installed?\n\nAnswer No. 10: 4) 4/0s 1) #4 ground, in a 2 1/2'  or 3  conduit, contractor s choice.\n\nQuestion No 11: Can an alternate route be considered? Outside above the canopyÂ walkway possibly? This would keep us from having to go through ER areas. \n\nAnswer No. 11: Conduit needs to be ran with existing conduits, everything currently ran on the outside is for temporary equipment only, permanent utilities need to be physically secured and away from damage.\n\nQuestion No. 12: Does the new feeder need to be in place and ready to terminate before we can demo the old feeder? Or can we demo old feeder as we install new feeder?\n\nAnswer No. 12: Yes, new feeder needs to be in place prior to demo of existing feeder, providing continuity of backup generator feed serving critical loads and patients.\n\nQuestion No. 13: Please confirm if we can do all of the install during normal working hours.\n\nAnswer No. 13: Normal business hours would be best as this is an emergency room, which never shuts down.","origin":"detail"},"contacts":[{"name":"Frances Basham (CO)","role":"primary","email":"Frances.Basham@va.gov","title":"Contracting Specialist"}],"place_of_performance":null,"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"naics_codes":["238210"],"award":{"awardee":{}},"attachments":[{"resource_id":"1e7248b9c0aa43cd87eeab15ad85d1b0","name":"va.gov","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2025-07-17T21:15:25.968Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov/oklahoma-city-health-care/","mirrored":false},{"resource_id":"37f4e396d13148e1b430bbbfc15dc7e2","name":"36C25925Q0638.docx","kind":"file","mime_type":".docx","size_bytes":102410,"posted_at":"2025-07-17T21:17:01.710Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/37f4e396d13148e1b430bbbfc15dc7e2/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C25925P1096_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C25925P1096_3600_-NONE-_-NONE-/","piid":"36C25925P1096","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"FAPZQ1BR9L58","recipient_name":"VETERANS PRE-CONSTRUCTION & VISUAL SOLUTIONS, LLC","recipient_uei":"FAPZQ1BR9L58","recipient_cage":"9E1Z3","recipient_city":"DALLAS","recipient_state":"TX","sub_name":"Department of Veterans Affairs","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","office_key":"o-36C259","first_action_date":"2025-09-09","last_action_date":"2025-11-25","actions":2,"obligated":"50104.50","current_total_value":"50104.50","potential_total_value":"50104.50","naics":"238210","psc":"Z2DZ","extent_competed":"COMPETED UNDER SAP","set_aside":"SERVICE DISABLED VETERAN OWNED SMALL BUSINESS SET-ASIDE","offers_received":4,"description":"REFEED ELECTRICAL","method":"solicitation","confidence":"high","evidence":["solicitation number 36C25925Q0638 equals the FPDS solicitation identifier","same awarding office 36C259"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C25927Q0058","latest_notice_id":"f7ba8da853564af6a36ca00b9a898459","title":"Q301--NEW | Automated Blood Bank Solid Phase Analyzer and Associated Reagents/Consumables","solicitation_number":"36C25927Q0058","notice_type":"r","first_type":"r","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-25T22:30:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T22:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"334516","psc":"Q301","set_aside":null,"state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"36C25927Q0048","latest_notice_id":"c63e9c1e32f4475caa79c878ba87ca2f","title":"Radiant Heating Panel Replacement","solicitation_number":"36C25927Q0048","notice_type":"k","first_type":"k","first_posted":"2026-11-04","last_posted":"2026-11-23","notices":3,"due_at":"2026-11-27T19:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"238220","psc":"J045","set_aside":"SBA","state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C25927Q0061","latest_notice_id":"2844a59e27da407db5c5aac404bd35d7","title":"AI tool for Medication Reconciliation and Clinical Review","solicitation_number":"36C25927Q0061","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"541519","psc":"DA10","set_aside":null,"state":"CO","county":"08077","county_name":"Mesa County","city":"0831660","city_name":"Grand Junction","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C25927Q0060","latest_notice_id":"dab1ae13fa4543da8629e3ba28875296","title":"J023-- Transmission Repair/Replacement x2","solicitation_number":"36C25927Q0060","notice_type":"k","first_type":"k","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-12-04T17:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"811111","psc":"J023","set_aside":"SBA","state":"UT","county":"49035","county_name":"Salt Lake County","city":"4967000","city_name":"Salt Lake City","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C25927Q0063","latest_notice_id":"3aec52f34d1346bcb89262decf41e0e9","title":"J045--Annual Boiler Maintenance RMR VAMC","solicitation_number":"36C25927Q0063","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-04T21:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"238220","psc":"J045","set_aside":null,"state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":"sam_zip","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open":[{"key":"MRKTSVY26ELECIDIQ","latest_notice_id":"5c4820e75c9f4e0094f8601d1fb5a711","title":"Electrical Construction Services IDIQ - MMAC","solicitation_number":"MRKTSVY-26-ElecIDIQ","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-09T22:00:00Z","due_date":"2026-12-09","closes_at":"2026-12-09T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-069","dept_name":"TRANSPORTATION, DEPARTMENT OF","sub_key":"s-6920","sub_name":"FEDERAL AVIATION ADMINISTRATION","office_key":"o-6973GH","office_name":"6973GH FRANCHISE ACQUISITION SVCS","naics":"238210","psc":null,"set_aside":"SBA","state":"OK","county":"40109","county_name":"Oklahoma County","city":"4055000","city_name":"Oklahoma City","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"1232SA27Q0021","latest_notice_id":"8c35373e3e5c4e3bb88b3fb51c3ea2c1","title":"Electrical Installation of 5-Station Cubicle and One Single Hotel Desk Arrangement","solicitation_number":"1232SA27Q0021","notice_type":"k","first_type":"k","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12H2","sub_name":"AGRICULTURAL RESEARCH SERVICE","office_key":"o-1232SA","office_name":"USDA ARS AFM APD","naics":"238210","psc":"N059","set_aside":"SBA","state":"WI","county":"55025","county_name":"Dane County","city":"5548000","city_name":"Madison","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"1240LU26Q0132","latest_notice_id":"7772e7cbaf1a46409b142ded751c8ec8","title":"USDA Forest Service - Hebgen Lake District Office Network Cabling and IT Room Improvements","solicitation_number":"1240LU26Q0132","notice_type":"k","first_type":"k","first_posted":"2026-09-24","last_posted":"2026-11-05","notices":4,"due_at":"2026-11-26T00:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-26T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12C2","sub_name":"FOREST SERVICE","office_key":"o-1240LU","office_name":"USDA-FS, CSA INTERMOUNTAIN 9","naics":"238210","psc":"N061","set_aside":"SBA","state":"MT","county":"30031","county_name":"Gallatin County","city":"3079525","city_name":"West Yellowstone","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-06T04:46:59.158685Z"}],"similar_open_total":41,"indexable":false}