{"canonical":"https://sealedbidder.com/opportunities/36c25925q0295","key":"36C25925Q0295","url":"https://sealedbidder.com/opportunities/36c25925q0295","title":"6540--St. George CBOC Optometry Equipment","solicitation_number":"36C25925Q0295","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-03-14T18:00:00Z","first_posted":"2025-03-11","last_posted":"2025-03-11","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"339115","psc":"6540","set_aside":null,"place_state":"UT","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"49053","place_county_name":"Washington County","place_city":"4965330","place_city_name":"St. George","winner":null,"award_amount":null,"publications":[{"notice_id":"030124802aa84588ab6b21dc3c389aad","title":"6540--St. George CBOC Optometry Equipment","solicitation_number":"36C25925Q0295","notice_type":"r","base_type":"r","posted":"2025-03-11","posted_at":"2025-03-11T23:16:10.530Z","due_at":"2025-03-14T18:00:00Z","due_date":"2025-03-14","cancelled":false,"archived":true,"archive_date":"2025-03-29","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/030124802aa84588ab6b21dc3c389aad/view","enriched":true,"history":[{"index":3,"title":"6540--St. George CBOC Optometry Equipment","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-11T23:16:10.530Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"030124802aa84588ab6b21dc3c389aad","solicitation_number":"36C25925Q0295"}]}],"latest_notice_id":"030124802aa84588ab6b21dc3c389aad","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-03-11","posted_at":"2025-03-11T23:16:10.530Z","created_at":"2025-03-11T23:16:08.091Z","modified_at":"2025-03-29T04:04:34.394Z","response_deadline":{"raw":"2025-03-14T12:00:00-06:00","utc":"2025-03-14T18:00:00Z","date":"2025-03-14","time":"12:00:00","timezone":"America/Denver","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/030124802aa84588ab6b21dc3c389aad/view"},"naics":{"codes":["339115"],"primary":"339115"},"title":"6540--St. George CBOC Optometry Equipment","agency":{"office":{"code":"36C259","name":"NETWORK CONTRACT OFFICE 19 (36C259)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"organization_id":"100176750","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-03-29","archive_type":"auto_custom"},"history":[{"index":3,"title":"6540--St. George CBOC Optometry Equipment","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-11T23:16:10.530Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"030124802aa84588ab6b21dc3c389aad","solicitation_number":"36C25925Q0295"}],"contacts":[{"name":"Stephanie Cahill","role":"primary","email":"Stephanie.Cahill@va.gov","phone":"303-712-5841","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"030124802aa84588ab6b21dc3c389aad","lineage_id":"030124802aa84588ab6b21dc3c389aad","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-20T13:20:40.298580381Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"688f0436cb12d2ad0286bc759e802c5120cb670d20b0dbc52959d643fcc93daf","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-20T13:20:40.298580381Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Sources Sought Notice\n\nSources Sought Notice\n\nPage 5 of 5\nSources Sought Notice\n*= Required Field\nSources Sought Notice\n\nPage 1 of 5\nThis is NOT a solicitation or request for quote (RFQ). This is NOT a request for proposal (RFP). This is NOT a job advertisement for hiring employees. The VA is seeking QUALIFIED VENDORS to provide a very brief response to this notice including only just what is asked for in this notice below. This is sources sought notice to industry and the only information is posted on Contract Opportunities web page at SAM.gov. Sources sought means seeking qualified vendors. The attachments included on the Contract Opportunities page do not include any additional information.\n\nIf your company is interested, please read this notice entirely and submit the required information, as requested herein.\n\nSt. George VA Outpatient Clinic Optometry Activation\nSalt Lake City VA Medical Center, Utah\n\nBRIEF SCOPE OF WORK\n(This is for information only)\n\nIMPORTANT NOTE:  This Sources Sought is for market research purposes only (to determine the socioeconomic status of interested companies). No award will be made off this posting.\n\nThe Salt Lake City VA Health Care System requires the following equipment for use in their newly activated St. George Optometry outpatient clinic.\n\nLine #\nDescription\nQty\n0001\nPower Table - Topcon AIT-250W Wheelchair - Accessible\n1\n0002\nOphthalmic Exam Chair\n1\n0003\nOphthalmic Floor Unit/ Instrument Stand\n1\n0004\nFull Diameter Trial Lens Set with Cylinders, Tray, and Case\n1\n\nSalient Characteristics:\n\nPower Table   Topcon AIT-250W Wheelchair Accessible\nTopcon brand strongly preferred but other equal products acceptable\nWheelchair accessible   ADA compliant\nHeight: 23  retracted; 49  full stroke\nDimensions (approx..): 36  x 24  x 29 \n\nOphthalmic Exam Chair (Haag-Streit Reliance brand preferred)\nDiameter: 24 1 /4 ,\nDepth of chair (without headrest) table position: 60 \nSeat: 18 3 /4  wide, 18 1 /4  deep\nTwo base heights. HIGH: 23 5 /8  lowered, 34 1 /4  raised. LOW 21 1 /8  lowered, 29 5 /8  raised.\nDistance between armrests: 19 \nStandard electric: 120 volts, 50/60 Hz, 6.3 amperes total. Optional electric: 230 volts, 50 Hz, 4.0 amperes.\n\nOphthalmic Floor Unit/ Instrument Stand (Haag-Streit Reliance brand preferred)\nFloor unit arm adjusts for instruments weighing between 12 and 60 lbs\nThe Upper Refractor arm have a 10  vertical range, and handle instruments weighing up to 20 lbs.\nHeight to console: 36  \nHeight to pole top: 71  \nBase: 21x 21  \nElectrical (Standard UL Listed), 115 volts, 60 Hz, 3 amperes\n\nFull Diameter Trial Lens Set with Cylinders, Tray, and Case\n70 Spherical Concave Lenses: 0.12 to 20.00 Diopters (0.12 / 0.25D increments)\n70 Spherical Convex Lenses: 0.12 to 20.00 Diopters (0.12 / 0.25D increments)\n34 Cylindrical Concave Lenses: 0.12 to 6.00 Diopters (0.12 / 0.25D increments)\n34 Cylindrical Convex lenses: 0.12 to 6.00 Diopters (0.12 / 0.25D increments)\n12 Prismatical Lenses: 0.5 (2), 1 (2), 3, 4, 5, 6, 7, 8\n8 Accessory Lenses: Red, Green, Slit, Occluder, Pin Hole (2), Cross Cylinder (2)\nMust come with tray and case to store trial lenses keeping them organized.\n\nThe Contractor, its employees, agents, and subcontractors shall not be considered VA employees for any purpose of fulfilling the PWS and shall be considered employees of the Contractor. Contractor shall furnish all labor, materials, equipment, tools, shipping, transportation, insurances, licenses, certifications, and supervision necessary to provide services in accordance with this Performance Work Statement (PWS). The Contractor is responsible for all charges and fees related to disposal of materials generated by the Contractor.\n\nThis is anticipated to be a commercial supply acquisition under the authority of FAR Part 12, Simplified Acquisition Procedures for Commercial Items. \n\nThe product will be delivered to the following location:\n\nGeorge VA CBOC\n585 East Riverside Drive, Suite 300\nSt. George, UT 84790-7141\n\n\nIMPORTANT NOTE:  This RFI (Request for Information) is for information only.\nNo award will be made from this RFI. \n\nQUALIFIED VENDOR: A qualified source has the a) necessary equipment, vehicles, personnel, resources and current operations as well as b) recent experience (within past 3 years) of performing services of a comparable size, scope and complexity, AND c) OEM certified technicians to perform services with unrestricted access to the facility during inclement weather, as well as immediate access to OEM software updates. A qualified source also has current and valid registration in System for Award Management (SAM), https://www.sam.gov). A qualified source will also be able to comply with Limitations of Subcontracting pursuant to FAR 19.507.\n\nPlease communicate via e-mail to Stephanie.Cahill@VA.Gov by 12:00 MST on March 14th, 2025, as to your company s ability to perform service per this brief Scope of Work.  \n\n\nIf interested, please provide the following:\n\nProvide company s capability statement describing ability to provide equipment that meets or conforms to the salient characteristics listed above *include specification or brochure documents for confirmation of equivalent products*\n\nCompany s business size in relation to NAICS 339115 and socio-economic category (SDVOSB/VOSB/WOSB/Large Business):\nSAM UEI:\nFSS/GSA contract # (if applicable):\nEstimated lead time:\nWhere are the products manufactured/COO:\n\nOnly written responses, to items 1 through 6 above, will be accepted at this stage. Information is being gathered for market research purposes only. Industry exchanges and vendor teleconferences are at the discretion of the Contract Specialist. This is not a request for quotes.   \n\nDISCLAIMER: This is a Request for Information (RFI) from industry in accordance with Federal Acquisition Regulation (FAR) 15.201(e) and on the requirement, that exists for the VA Medical Center(s) identified in this RFI. This is not a request for quote and not a contract. This announcement is not a request for proposals; therefore, responses to the RFI are not considered offers and cannot be accepted by the Government to form a binding contract. This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responders are solely responsible for all expenses associated with responding to this RFI. No classified information should be included in the RFI response. Should you have concerns regarding this RFI you may request to contact the Contracting Office that will be assigned this requirement by emailing the sender of this RFI. \n\nQuestions must be addressed in writing to the Contract Specialist. Requests for VA-business sensitive information, to include VA budget information, VA acquisition planning information, acquisition methods, strategies and set-asides must be addressed via the VA FOIA process: https://www.va.gov/foia/\n\nThank you for your interest in doing business with the VA. To learn more about the VA Mission, Vision, Core Values & Goals visit https://www.va.gov/about_va/mission.asp \n\nTo understand the latest updates on the Veterans First Contracting Program visit https://www.va.gov/osdbu/verification/veterans_first_contracting_program_adjustments_to_reflect_the_supreme_court_kingdomware_decision.asp \n \nTo find out how to do business with the VA visit https://www.va.gov/osdbu/library/dbwva.asp","text":"Sources Sought Notice\n\nSources Sought Notice\n\nPage 5 of 5\nSources Sought Notice\n*= Required Field\nSources Sought Notice\n\nPage 1 of 5\nThis is NOT a solicitation or request for quote (RFQ). This is NOT a request for proposal (RFP). This is NOT a job advertisement for hiring employees. The VA is seeking QUALIFIED VENDORS to provide a very brief response to this notice including only just what is asked for in this notice below. This is sources sought notice to industry and the only information is posted on Contract Opportunities web page at SAM.gov. Sources sought means seeking qualified vendors. The attachments included on the Contract Opportunities page do not include any additional information.\n\nIf your company is interested, please read this notice entirely and submit the required information, as requested herein.\n\nSt. George VA Outpatient Clinic Optometry Activation\nSalt Lake City VA Medical Center, Utah\n\nBRIEF SCOPE OF WORK\n(This is for information only)\n\nIMPORTANT NOTE: This Sources Sought is for market research purposes only (to determine the socioeconomic status of interested companies). No award will be made off this posting.\n\nThe Salt Lake City VA Health Care System requires the following equipment for use in their newly activated St. George Optometry outpatient clinic.\n\nLine #\nDescription\nQty\n0001\nPower Table - Topcon AIT-250W Wheelchair - Accessible\n1\n0002\nOphthalmic Exam Chair\n1\n0003\nOphthalmic Floor Unit/ Instrument Stand\n1\n0004\nFull Diameter Trial Lens Set with Cylinders, Tray, and Case\n1\n\nSalient Characteristics:\n\nPower Table Topcon AIT-250W Wheelchair Accessible\nTopcon brand strongly preferred but other equal products acceptable\nWheelchair accessible ADA compliant\nHeight: 23 retracted; 49 full stroke\nDimensions (approx..): 36 x 24 x 29\n\nOphthalmic Exam Chair (Haag-Streit Reliance brand preferred)\nDiameter: 24 1 /4 ,\nDepth of chair (without headrest) table position: 60\nSeat: 18 3 /4 wide, 18 1 /4 deep\nTwo base heights. HIGH: 23 5 /8 lowered, 34 1 /4 raised. LOW 21 1 /8 lowered, 29 5 /8 raised.\nDistance between armrests: 19\nStandard electric: 120 volts, 50/60 Hz, 6.3 amperes total. Optional electric: 230 volts, 50 Hz, 4.0 amperes.\n\nOphthalmic Floor Unit/ Instrument Stand (Haag-Streit Reliance brand preferred)\nFloor unit arm adjusts for instruments weighing between 12 and 60 lbs\nThe Upper Refractor arm have a 10 vertical range, and handle instruments weighing up to 20 lbs.\nHeight to console: 36\nHeight to pole top: 71\nBase: 21x 21\nElectrical (Standard UL Listed), 115 volts, 60 Hz, 3 amperes\n\nFull Diameter Trial Lens Set with Cylinders, Tray, and Case\n70 Spherical Concave Lenses: 0.12 to 20.00 Diopters (0.12 / 0.25D increments)\n70 Spherical Convex Lenses: 0.12 to 20.00 Diopters (0.12 / 0.25D increments)\n34 Cylindrical Concave Lenses: 0.12 to 6.00 Diopters (0.12 / 0.25D increments)\n34 Cylindrical Convex lenses: 0.12 to 6.00 Diopters (0.12 / 0.25D increments)\n12 Prismatical Lenses: 0.5 (2), 1 (2), 3, 4, 5, 6, 7, 8\n8 Accessory Lenses: Red, Green, Slit, Occluder, Pin Hole (2), Cross Cylinder (2)\nMust come with tray and case to store trial lenses keeping them organized.\n\nThe Contractor, its employees, agents, and subcontractors shall not be considered VA employees for any purpose of fulfilling the PWS and shall be considered employees of the Contractor. Contractor shall furnish all labor, materials, equipment, tools, shipping, transportation, insurances, licenses, certifications, and supervision necessary to provide services in accordance with this Performance Work Statement (PWS). The Contractor is responsible for all charges and fees related to disposal of materials generated by the Contractor.\n\nThis is anticipated to be a commercial supply acquisition under the authority of FAR Part 12, Simplified Acquisition Procedures for Commercial Items.\n\nThe product will be delivered to the following location:\n\nGeorge VA CBOC\n585 East Riverside Drive, Suite 300\nSt. George, UT 84790-7141\n\nIMPORTANT NOTE: This RFI (Request for Information) is for information only.\nNo award will be made from this RFI.\n\nQUALIFIED VENDOR: A qualified source has the a) necessary equipment, vehicles, personnel, resources and current operations as well as b) recent experience (within past 3 years) of performing services of a comparable size, scope and complexity, AND c) OEM certified technicians to perform services with unrestricted access to the facility during inclement weather, as well as immediate access to OEM software updates. A qualified source also has current and valid registration in System for Award Management (SAM), https://www.sam.gov). A qualified source will also be able to comply with Limitations of Subcontracting pursuant to FAR 19.507.\n\nPlease communicate via e-mail to Stephanie.Cahill@VA.Gov by 12:00 MST on March 14th, 2025, as to your company s ability to perform service per this brief Scope of Work.\n\nIf interested, please provide the following:\n\nProvide company s capability statement describing ability to provide equipment that meets or conforms to the salient characteristics listed above *include specification or brochure documents for confirmation of equivalent products*\n\nCompany s business size in relation to NAICS 339115 and socio-economic category (SDVOSB/VOSB/WOSB/Large Business):\nSAM UEI:\nFSS/GSA contract # (if applicable):\nEstimated lead time:\nWhere are the products manufactured/COO:\n\nOnly written responses, to items 1 through 6 above, will be accepted at this stage. Information is being gathered for market research purposes only. Industry exchanges and vendor teleconferences are at the discretion of the Contract Specialist. This is not a request for quotes.\n\nDISCLAIMER: This is a Request for Information (RFI) from industry in accordance with Federal Acquisition Regulation (FAR) 15.201(e) and on the requirement, that exists for the VA Medical Center(s) identified in this RFI. This is not a request for quote and not a contract. This announcement is not a request for proposals; therefore, responses to the RFI are not considered offers and cannot be accepted by the Government to form a binding contract. This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responders are solely responsible for all expenses associated with responding to this RFI. No classified information should be included in the RFI response. Should you have concerns regarding this RFI you may request to contact the Contracting Office that will be assigned this requirement by emailing the sender of this RFI.\n\nQuestions must be addressed in writing to the Contract Specialist. Requests for VA-business sensitive information, to include VA budget information, VA acquisition planning information, acquisition methods, strategies and set-asides must be addressed via the VA FOIA process: https://www.va.gov/foia/\n\nThank you for your interest in doing business with the VA. To learn more about the VA Mission, Vision, Core Values & Goals visit https://www.va.gov/about_va/mission.asp\n\nTo understand the latest updates on the Veterans First Contracting Program visit https://www.va.gov/osdbu/verification/veterans_first_contracting_program_adjustments_to_reflect_the_supreme_court_kingdomware_decision.asp\n\nTo find out how to do business with the VA visit https://www.va.gov/osdbu/library/dbwva.asp","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25925Q0295","place_of_performance":{"zip":"84790","city":{"name":"St. George"},"state":{"code":"UT","name":"Utah"},"street":"St. George VA Outpatient Clinic","country":{"code":"USA","name":"UNITED STATES"},"street2":"585 East Riverside Drive, STE 300"},"product_service_code":"6540"}],"due_at":"2025-03-14T18:00:00Z","due_date":"2025-03-14","closes_at":"2025-03-14T18:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","state":"UT","county":"49053","county_name":"Washington County","city":"4965330","city_name":"St. George","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-20T14:09:51.776087Z","principal_notice_id":"030124802aa84588ab6b21dc3c389aad","description":{"text":"Sources Sought Notice\n\nSources Sought Notice\n\nPage 5 of 5\nSources Sought Notice\n*= Required Field\nSources Sought Notice\n\nPage 1 of 5\nThis is NOT a solicitation or request for quote (RFQ). This is NOT a request for proposal (RFP). This is NOT a job advertisement for hiring employees. The VA is seeking QUALIFIED VENDORS to provide a very brief response to this notice including only just what is asked for in this notice below. This is sources sought notice to industry and the only information is posted on Contract Opportunities web page at SAM.gov. Sources sought means seeking qualified vendors. The attachments included on the Contract Opportunities page do not include any additional information.\n\nIf your company is interested, please read this notice entirely and submit the required information, as requested herein.\n\nSt. George VA Outpatient Clinic Optometry Activation\nSalt Lake City VA Medical Center, Utah\n\nBRIEF SCOPE OF WORK\n(This is for information only)\n\nIMPORTANT NOTE: This Sources Sought is for market research purposes only (to determine the socioeconomic status of interested companies). No award will be made off this posting.\n\nThe Salt Lake City VA Health Care System requires the following equipment for use in their newly activated St. George Optometry outpatient clinic.\n\nLine #\nDescription\nQty\n0001\nPower Table - Topcon AIT-250W Wheelchair - Accessible\n1\n0002\nOphthalmic Exam Chair\n1\n0003\nOphthalmic Floor Unit/ Instrument Stand\n1\n0004\nFull Diameter Trial Lens Set with Cylinders, Tray, and Case\n1\n\nSalient Characteristics:\n\nPower Table Topcon AIT-250W Wheelchair Accessible\nTopcon brand strongly preferred but other equal products acceptable\nWheelchair accessible ADA compliant\nHeight: 23 retracted; 49 full stroke\nDimensions (approx..): 36 x 24 x 29\n\nOphthalmic Exam Chair (Haag-Streit Reliance brand preferred)\nDiameter: 24 1 /4 ,\nDepth of chair (without headrest) table position: 60\nSeat: 18 3 /4 wide, 18 1 /4 deep\nTwo base heights. HIGH: 23 5 /8 lowered, 34 1 /4 raised. LOW 21 1 /8 lowered, 29 5 /8 raised.\nDistance between armrests: 19\nStandard electric: 120 volts, 50/60 Hz, 6.3 amperes total. Optional electric: 230 volts, 50 Hz, 4.0 amperes.\n\nOphthalmic Floor Unit/ Instrument Stand (Haag-Streit Reliance brand preferred)\nFloor unit arm adjusts for instruments weighing between 12 and 60 lbs\nThe Upper Refractor arm have a 10 vertical range, and handle instruments weighing up to 20 lbs.\nHeight to console: 36\nHeight to pole top: 71\nBase: 21x 21\nElectrical (Standard UL Listed), 115 volts, 60 Hz, 3 amperes\n\nFull Diameter Trial Lens Set with Cylinders, Tray, and Case\n70 Spherical Concave Lenses: 0.12 to 20.00 Diopters (0.12 / 0.25D increments)\n70 Spherical Convex Lenses: 0.12 to 20.00 Diopters (0.12 / 0.25D increments)\n34 Cylindrical Concave Lenses: 0.12 to 6.00 Diopters (0.12 / 0.25D increments)\n34 Cylindrical Convex lenses: 0.12 to 6.00 Diopters (0.12 / 0.25D increments)\n12 Prismatical Lenses: 0.5 (2), 1 (2), 3, 4, 5, 6, 7, 8\n8 Accessory Lenses: Red, Green, Slit, Occluder, Pin Hole (2), Cross Cylinder (2)\nMust come with tray and case to store trial lenses keeping them organized.\n\nThe Contractor, its employees, agents, and subcontractors shall not be considered VA employees for any purpose of fulfilling the PWS and shall be considered employees of the Contractor. Contractor shall furnish all labor, materials, equipment, tools, shipping, transportation, insurances, licenses, certifications, and supervision necessary to provide services in accordance with this Performance Work Statement (PWS). The Contractor is responsible for all charges and fees related to disposal of materials generated by the Contractor.\n\nThis is anticipated to be a commercial supply acquisition under the authority of FAR Part 12, Simplified Acquisition Procedures for Commercial Items.\n\nThe product will be delivered to the following location:\n\nGeorge VA CBOC\n585 East Riverside Drive, Suite 300\nSt. George, UT 84790-7141\n\nIMPORTANT NOTE: This RFI (Request for Information) is for information only.\nNo award will be made from this RFI.\n\nQUALIFIED VENDOR: A qualified source has the a) necessary equipment, vehicles, personnel, resources and current operations as well as b) recent experience (within past 3 years) of performing services of a comparable size, scope and complexity, AND c) OEM certified technicians to perform services with unrestricted access to the facility during inclement weather, as well as immediate access to OEM software updates. A qualified source also has current and valid registration in System for Award Management (SAM), https://www.sam.gov). A qualified source will also be able to comply with Limitations of Subcontracting pursuant to FAR 19.507.\n\nPlease communicate via e-mail to Stephanie.Cahill@VA.Gov by 12:00 MST on March 14th, 2025, as to your company s ability to perform service per this brief Scope of Work.\n\nIf interested, please provide the following:\n\nProvide company s capability statement describing ability to provide equipment that meets or conforms to the salient characteristics listed above *include specification or brochure documents for confirmation of equivalent products*\n\nCompany s business size in relation to NAICS 339115 and socio-economic category (SDVOSB/VOSB/WOSB/Large Business):\nSAM UEI:\nFSS/GSA contract # (if applicable):\nEstimated lead time:\nWhere are the products manufactured/COO:\n\nOnly written responses, to items 1 through 6 above, will be accepted at this stage. Information is being gathered for market research purposes only. Industry exchanges and vendor teleconferences are at the discretion of the Contract Specialist. This is not a request for quotes.\n\nDISCLAIMER: This is a Request for Information (RFI) from industry in accordance with Federal Acquisition Regulation (FAR) 15.201(e) and on the requirement, that exists for the VA Medical Center(s) identified in this RFI. This is not a request for quote and not a contract. This announcement is not a request for proposals; therefore, responses to the RFI are not considered offers and cannot be accepted by the Government to form a binding contract. This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responders are solely responsible for all expenses associated with responding to this RFI. No classified information should be included in the RFI response. Should you have concerns regarding this RFI you may request to contact the Contracting Office that will be assigned this requirement by emailing the sender of this RFI.\n\nQuestions must be addressed in writing to the Contract Specialist. Requests for VA-business sensitive information, to include VA budget information, VA acquisition planning information, acquisition methods, strategies and set-asides must be addressed via the VA FOIA process: https://www.va.gov/foia/\n\nThank you for your interest in doing business with the VA. To learn more about the VA Mission, Vision, Core Values & Goals visit https://www.va.gov/about_va/mission.asp\n\nTo understand the latest updates on the Veterans First Contracting Program visit https://www.va.gov/osdbu/verification/veterans_first_contracting_program_adjustments_to_reflect_the_supreme_court_kingdomware_decision.asp\n\nTo find out how to do business with the VA visit https://www.va.gov/osdbu/library/dbwva.asp","html":"Sources Sought Notice\n\nSources Sought Notice\n\nPage 5 of 5\nSources Sought Notice\n*= Required Field\nSources Sought Notice\n\nPage 1 of 5\nThis is NOT a solicitation or request for quote (RFQ). This is NOT a request for proposal (RFP). This is NOT a job advertisement for hiring employees. The VA is seeking QUALIFIED VENDORS to provide a very brief response to this notice including only just what is asked for in this notice below. This is sources sought notice to industry and the only information is posted on Contract Opportunities web page at SAM.gov. Sources sought means seeking qualified vendors. The attachments included on the Contract Opportunities page do not include any additional information.\n\nIf your company is interested, please read this notice entirely and submit the required information, as requested herein.\n\nSt. George VA Outpatient Clinic Optometry Activation\nSalt Lake City VA Medical Center, Utah\n\nBRIEF SCOPE OF WORK\n(This is for information only)\n\nIMPORTANT NOTE:  This Sources Sought is for market research purposes only (to determine the socioeconomic status of interested companies). No award will be made off this posting.\n\nThe Salt Lake City VA Health Care System requires the following equipment for use in their newly activated St. George Optometry outpatient clinic.\n\nLine #\nDescription\nQty\n0001\nPower Table - Topcon AIT-250W Wheelchair - Accessible\n1\n0002\nOphthalmic Exam Chair\n1\n0003\nOphthalmic Floor Unit/ Instrument Stand\n1\n0004\nFull Diameter Trial Lens Set with Cylinders, Tray, and Case\n1\n\nSalient Characteristics:\n\nPower Table   Topcon AIT-250W Wheelchair Accessible\nTopcon brand strongly preferred but other equal products acceptable\nWheelchair accessible   ADA compliant\nHeight: 23  retracted; 49  full stroke\nDimensions (approx..): 36  x 24  x 29 \n\nOphthalmic Exam Chair (Haag-Streit Reliance brand preferred)\nDiameter: 24 1 /4 ,\nDepth of chair (without headrest) table position: 60 \nSeat: 18 3 /4  wide, 18 1 /4  deep\nTwo base heights. HIGH: 23 5 /8  lowered, 34 1 /4  raised. LOW 21 1 /8  lowered, 29 5 /8  raised.\nDistance between armrests: 19 \nStandard electric: 120 volts, 50/60 Hz, 6.3 amperes total. Optional electric: 230 volts, 50 Hz, 4.0 amperes.\n\nOphthalmic Floor Unit/ Instrument Stand (Haag-Streit Reliance brand preferred)\nFloor unit arm adjusts for instruments weighing between 12 and 60 lbs\nThe Upper Refractor arm have a 10  vertical range, and handle instruments weighing up to 20 lbs.\nHeight to console: 36  \nHeight to pole top: 71  \nBase: 21x 21  \nElectrical (Standard UL Listed), 115 volts, 60 Hz, 3 amperes\n\nFull Diameter Trial Lens Set with Cylinders, Tray, and Case\n70 Spherical Concave Lenses: 0.12 to 20.00 Diopters (0.12 / 0.25D increments)\n70 Spherical Convex Lenses: 0.12 to 20.00 Diopters (0.12 / 0.25D increments)\n34 Cylindrical Concave Lenses: 0.12 to 6.00 Diopters (0.12 / 0.25D increments)\n34 Cylindrical Convex lenses: 0.12 to 6.00 Diopters (0.12 / 0.25D increments)\n12 Prismatical Lenses: 0.5 (2), 1 (2), 3, 4, 5, 6, 7, 8\n8 Accessory Lenses: Red, Green, Slit, Occluder, Pin Hole (2), Cross Cylinder (2)\nMust come with tray and case to store trial lenses keeping them organized.\n\nThe Contractor, its employees, agents, and subcontractors shall not be considered VA employees for any purpose of fulfilling the PWS and shall be considered employees of the Contractor. Contractor shall furnish all labor, materials, equipment, tools, shipping, transportation, insurances, licenses, certifications, and supervision necessary to provide services in accordance with this Performance Work Statement (PWS). The Contractor is responsible for all charges and fees related to disposal of materials generated by the Contractor.\n\nThis is anticipated to be a commercial supply acquisition under the authority of FAR Part 12, Simplified Acquisition Procedures for Commercial Items. \n\nThe product will be delivered to the following location:\n\nGeorge VA CBOC\n585 East Riverside Drive, Suite 300\nSt. George, UT 84790-7141\n\n\nIMPORTANT NOTE:  This RFI (Request for Information) is for information only.\nNo award will be made from this RFI. \n\nQUALIFIED VENDOR: A qualified source has the a) necessary equipment, vehicles, personnel, resources and current operations as well as b) recent experience (within past 3 years) of performing services of a comparable size, scope and complexity, AND c) OEM certified technicians to perform services with unrestricted access to the facility during inclement weather, as well as immediate access to OEM software updates. A qualified source also has current and valid registration in System for Award Management (SAM), https://www.sam.gov). A qualified source will also be able to comply with Limitations of Subcontracting pursuant to FAR 19.507.\n\nPlease communicate via e-mail to Stephanie.Cahill@VA.Gov by 12:00 MST on March 14th, 2025, as to your company s ability to perform service per this brief Scope of Work.  \n\n\nIf interested, please provide the following:\n\nProvide company s capability statement describing ability to provide equipment that meets or conforms to the salient characteristics listed above *include specification or brochure documents for confirmation of equivalent products*\n\nCompany s business size in relation to NAICS 339115 and socio-economic category (SDVOSB/VOSB/WOSB/Large Business):\nSAM UEI:\nFSS/GSA contract # (if applicable):\nEstimated lead time:\nWhere are the products manufactured/COO:\n\nOnly written responses, to items 1 through 6 above, will be accepted at this stage. Information is being gathered for market research purposes only. Industry exchanges and vendor teleconferences are at the discretion of the Contract Specialist. This is not a request for quotes.   \n\nDISCLAIMER: This is a Request for Information (RFI) from industry in accordance with Federal Acquisition Regulation (FAR) 15.201(e) and on the requirement, that exists for the VA Medical Center(s) identified in this RFI. This is not a request for quote and not a contract. This announcement is not a request for proposals; therefore, responses to the RFI are not considered offers and cannot be accepted by the Government to form a binding contract. This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responders are solely responsible for all expenses associated with responding to this RFI. No classified information should be included in the RFI response. Should you have concerns regarding this RFI you may request to contact the Contracting Office that will be assigned this requirement by emailing the sender of this RFI. \n\nQuestions must be addressed in writing to the Contract Specialist. Requests for VA-business sensitive information, to include VA budget information, VA acquisition planning information, acquisition methods, strategies and set-asides must be addressed via the VA FOIA process: https://www.va.gov/foia/\n\nThank you for your interest in doing business with the VA. To learn more about the VA Mission, Vision, Core Values & Goals visit https://www.va.gov/about_va/mission.asp \n\nTo understand the latest updates on the Veterans First Contracting Program visit https://www.va.gov/osdbu/verification/veterans_first_contracting_program_adjustments_to_reflect_the_supreme_court_kingdomware_decision.asp \n \nTo find out how to do business with the VA visit https://www.va.gov/osdbu/library/dbwva.asp","origin":"detail"},"contacts":[{"name":"Stephanie Cahill","role":"primary","email":"Stephanie.Cahill@va.gov","phone":"303-712-5841","title":"Contract Specialist"}],"place_of_performance":{"zip":"84790","city":{"name":"St. George"},"state":{"code":"UT","name":"Utah"},"street":"St. George VA Outpatient Clinic","country":{"code":"USA","name":"UNITED STATES"},"street2":"585 East Riverside Drive, STE 300"},"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"naics_codes":["339115"],"award":{"awardee":{}},"attachments":[{"resource_id":"068645762b464e868111612605ff5f8a","name":"36C25925Q0295.docx","kind":"file","mime_type":".docx","size_bytes":23981,"posted_at":"2025-03-11T23:16:10.530Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/068645762b464e868111612605ff5f8a/download","mirrored":false}],"awards":[],"related":[{"key":"36C25927Q0058","latest_notice_id":"f7ba8da853564af6a36ca00b9a898459","title":"Q301--NEW | Automated Blood Bank Solid Phase Analyzer and Associated Reagents/Consumables","solicitation_number":"36C25927Q0058","notice_type":"r","first_type":"r","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-25T22:30:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T22:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"334516","psc":"Q301","set_aside":null,"state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"36C25927Q0048","latest_notice_id":"c63e9c1e32f4475caa79c878ba87ca2f","title":"Radiant Heating Panel Replacement","solicitation_number":"36C25927Q0048","notice_type":"k","first_type":"k","first_posted":"2026-11-04","last_posted":"2026-11-23","notices":3,"due_at":"2026-11-27T19:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"238220","psc":"J045","set_aside":"SBA","state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C25927Q0061","latest_notice_id":"2844a59e27da407db5c5aac404bd35d7","title":"AI tool for Medication Reconciliation and Clinical Review","solicitation_number":"36C25927Q0061","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"541519","psc":"DA10","set_aside":null,"state":"CO","county":"08077","county_name":"Mesa County","city":"0831660","city_name":"Grand Junction","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C25927Q0060","latest_notice_id":"dab1ae13fa4543da8629e3ba28875296","title":"J023-- Transmission Repair/Replacement x2","solicitation_number":"36C25927Q0060","notice_type":"k","first_type":"k","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-12-04T17:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"811111","psc":"J023","set_aside":"SBA","state":"UT","county":"49035","county_name":"Salt Lake County","city":"4967000","city_name":"Salt Lake City","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C25927Q0063","latest_notice_id":"3aec52f34d1346bcb89262decf41e0e9","title":"J045--Annual Boiler Maintenance RMR VAMC","solicitation_number":"36C25927Q0063","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-04T21:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"238220","psc":"J045","set_aside":null,"state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":"sam_zip","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open":[{"key":"IHS1511834","latest_notice_id":"559b1d390dfc49219e971609697c3bef","title":"All in one visual acuity system","solicitation_number":"IHS1511834","notice_type":"p","first_type":"p","first_posted":"2025-04-21","last_posted":"2025-04-21","notices":1,"due_at":"2029-04-29T12:00:00Z","due_date":"2029-04-29","closes_at":"2029-04-29T12:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7527","sub_name":"INDIAN HEALTH SERVICE","office_key":"o-75H710","office_name":"NAVAJO AREA INDIAN HEALTH SVC","naics":"339115","psc":"6540","set_aside":"ISBEE","state":"NM","county":"35031","county_name":"McKinley County","city":"3518940","city_name":"Crownpoint","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-24T03:25:58.922164Z"}],"similar_open_total":1,"indexable":false}