Skip to content

SealedBidder is a private company, not a government agency.

Sign upDashboard
  • 8,677 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell SealedBidder what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and SealedBidder tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $99 a month. See your matches before you pay.
See plans

Sources sought, service-disabled veteran-owned small business set-aside

UPS PM 623-25-1-5064-0042

36C25925Q0178

Department of Veterans Affairs, Network Contract Office 19. Electronic and Precision Equipment Repair and Maintenance.

Response deadline

February 11, 2025 at 4:00 PM EST

Closed 652 days ago. Posted February 5, 2025. Scheduled to archive May 12, 2025.

Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities

This one closed in 2025

61 like it are open now in electronic and precision equipment repair and maintenance

All 61 open in electronic and precision equipment repair and maintenance

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
Who may compete
Service-disabled veteran-owned small business set-aside. Reserved for service-disabled veteran-owned small businesses. Small, under NAICS 811210 (electronic and precision equipment repair and maintenance), means no more than $34 million in average annual receipts, counted with affiliates. Open SDVOSB opportunities
What comes next
No solicitation was published under this number after the sources sought of February 5, 2025. An agency sometimes issues the solicitation under a new number.

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov.

Performance Work Statement (PWS) Uninterruptible Power Supply Preventative Maintenance Department of Veterans Affairs (VA) Veterans Health Administration (VHA) (Brief Scope of Work) PURPOSE Veterans Affairs has a requirement for Uninterruptible Power Supply Preventative Maintenance services at the Eastern Oklahoma VA Health Care System (EOVAHCS). Services are to be performed in accordance with this PWS and to OEM standards, with the intent of ensuring the equipment operates as the original manufacturer intended, uninterrupted (95% uptime), in a cost-effective, efficient manner, contributing to the VA Mission. This is a non-personal services contract. The Contractor, its employees, agents and subcontractors shall not be considered VA employees for any purpose of fulfilling the SOW and shall be considered employees of the Contractor. C&A requirements do not apply, and a Security Accreditation Package is not required. LOCATION: Eastern Oklahoma VA Health Care System (EOVAHCS) 921 NE 13th St. Oklahoma City, OK 73104 TASKS AND REQUIREMENTS: Title of Project: Eaton Three Phase Uninterruptable Power Supply (UPS) Service Plan. Scope of Work: The contractor shall provide inspection and preventative maintenance on the Power Module and batteries annually. Battery replacement is not included. The UPS is located in building 22 at the Jack C. Montgomery VAMC. The C&A requirements do not apply, and a Security Accreditation Package is not required. Services include: 7x24 Emergency Service Coverage including parts, labor and travel Annual 5x8 Preventive Maintenance Inspection Annual 5x8 Comprehensive Battery Inspection Eight (8) Hour (maximum) Response Time Web Access to Service History Background: UPS is utilized at the Jack C. Montgomery VA Medical Center to prevent any power fluctuations that may affect any computer equipment in the server room. Equipment to be covered is: Eaton 9355-30 Serial Number EA024KXX10 Description of Tasks and Associated Deliverables: The contractor shall provide inspection of all UPS components and batteries in accordance with manufacturer s recommendations. If for any reason, any deliverable cannot be delivered on time according to the below schedule, the contractor shall provide a written explanation three days prior to the due date to the Contracting Officers Representative (COR). This written transmittal shall include a firm commitment of when the work shall be completed. This transmittal shall include a firm commitment of when the work shall be completed. This transmittal to the COR shall cite reasons for the delay and the impact on the overall project. The COR will review and issue a response in accordance with the contract terms and conditions. Specifically, the contractor shall: Task One: The contractor shall inspect all UPS components in accordance with manufacturer s recommendations. Corrective Maintenance Coverage: Inspection and repair of the electronic portion of the UPS (or other equipment type), or Power Module Deliverable One: Visual Inspection Inspect all printed circuit board connections for cleanliness, swab contacts if necessary. Inspect all power connections for signs of overheating. Inspect all subassemblies, bridges and legs for signs of component defects or stress. Inspect all DC capacitors for signs of leakage. Inspect all AC capacitors for sings of leakage. Inspect and inventory all customer-owned spare parts. Inspect for, and perform as required, any open engineering changes. Internal Operating Parameters DC Ground Detection Offset (if applicable) Inverter leg current average balance (if applicable) Output filter current average phase balance Rectifier bridge current average leg balance AC Protection settings are checked DC Protection settings are checked Input and Output Frequency and Voltage Bandwidth settings are checked Verify DC filter capacitance Verify AC tank and trap filter capacitance Power Supply voltages and waveforms External Operating Parameters System Input Voltages (all phases) System Input Currents (all phases) DC Charging Voltages (float and equalize), record settings, adjust to nominal Rectifier phase on and walk up Inverter phase on and walk up Adjust all panel meters to measured values System Bypass Voltages (all phases) Manual and UV Transfer testing, verify uninterrupted transfer waveform (if applicable) Outage simulation and battery capability testing and verify charger current limit Generator operation and interface verification (if applicable) Environmental Parameters UPS area ambient temperature and condition of ventilating equipment General Cleanliness of UPS Power Module General Cleanliness of UPS area Replace all air filters Clean control panel/CRT screen Flywheel only: Drain oil and change oil and filters Battery Cabinet Checks General appearance of Battery System General cleanliness of Battery system area Inspect cells for physical abnormalities Inspect all DC connections for abnormalities Battery system area ambient temperature and condition of ventilating equipment For internal batteries only, measure and record: Overall battery float voltage Charger input current and voltage Negative terminal temperature of one cell/battery per battery cabinet shelf or rack tier Monitoring System Parameters Alarm archive review and printing Alarm lamp test-local and remote (if applicable) Replace all open monitor bulbs Review battery test in history (if applicable) General Customer Consultation Verbal Recommendations General Observations Task Two: The contractor shall inspect all UPS batteries in accordance with manufacturer s recommendations Deliverable Two: Measure and Record Battery performance Individual cell/battery float voltages and overall float voltage Charger output current and voltage AC ripple current and voltage imposed on battery Internal ohmic values of each cell/battery or perform a continuity test of each cell/battery Connection Resistance of 10% of the inter cell/battery connection Ambient temperature Negative terminal temperature of one cell/battery per battery cabinet shelf or rack tier Visually inspect conditions and appearance of the following Connection terminal inter cell/battery connectors, cables and associated hardware Cell/battery covers, containers and post seals Battery racks or cabinets and associated components and hardware Cell/battery jar or cover, noting any excessive distortion Perform cleaning of all accessible surfaces as required Measure and record the connection resistance of 100% of the inter cell/battery connections yearly Re-torque any connection where the resistance is above 20% of the average yearly The technician(s) will issue the customer a verbal report summarizing the condition of the battery and identifying any critical issues before leaving the customer s site. A detailed report containing all reading and observations will be sent to the customer within 5 business days Technical support 7x24: technical support via telephone or email. Contractor shall be available to answer product or support questions. Attachment A Schedule of Deliverables Deliverable No. Task 1 Item Visual Inspection Delivery Date Within 30 days after contract award Task 1 Internal Operating Parameters Within 30 days after contract award Task 1 External Operating Parameters Within 30 days after contract award Task 1 Battery Cabinet Checks Within 30 days after contract award Task 1 Monitoring System Parameters Within 30 days after contract award Task 1 General Within 30 days after contract award Task 2 Measure and Record Battery Performance Within 30 days after contract award Task 2 Visually inspect conditions and appearance Within 30 days after contract award Task 2 Technical Support 7 x 24 At contract award IMPORTANT NOTE: This Sources Sought is for information only (to determine the socioeconomic status of interested companies). No award will be made off of this posting. LIMITATIONS OF SUBCONTRACTING: The Limitations of Subcontracting may or may not apply to a resulting solicitation from this Market Research. Vendors are advised to familiarize themselves with Federal Acquisition Regulation parts 19.505(a)(2) and 19.505(b)(1) as it pertains to subcontracting limitations. Vendors are also advised to familiarize themselves with 13 CFR 125.6 and the penalties described in this regulation. Please communicate via e-mail to tiffani.perkins@va.gov by COB 2/11/2025 as to your company s interest and ability to perform service per this brief Scope of Work. If interested, please provide the following: Please state your company s business size as related to NAICS code 811210 As per the Limitations of Subcontracting: (see FAR 19.505) As Primary Contractor: what % of Total Contract Value will you retain? If using a Subcontractor: what % of Total Contract Value will go to them? Please provide SAMs Unique Entity Identifier number If you have an FSS/GSA contract that includes this service Provide FSS/GSA contract number if applicable   In order for you company s information to be counted in relation to this Market Research all above questions must be answered.

Attachments

Files and links listed on SAM.gov. Files we hold a copy of download from here; the rest open SAM's download, which needs no account. Links open the sites the agency named.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. February 5, 2025

    Sources sought

    Due February 11, 2025 at 4:00 PM EST. SAM.gov, notice df6a425bccec42c3a478b327d4c95ce5

    1 revision on SAM
    • February 5, 2025: publish, sources sought

Points of contact