Skip to content

SealedBidder is a private company, not a government agency.

Sign upDashboard
  • 8,658 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell SealedBidder what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and SealedBidder tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $99 a month. See your matches before you pay.
See plans

Sources sought

Fire Suppresion System Maintenance and Testing

36C25925Q0030

Department of Veterans Affairs, Network Contract Office 19. Security Systems Services (except Locksmiths).

Response deadline

October 18, 2024 at 4:00 PM EDT

Closed 768 days ago. Posted October 11, 2024. Scheduled to archive November 17, 2024.

Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities

This one closed in 2024

27 like it are open now in security systems services (except locksmiths)

All 27 open in security systems services (except locksmiths)

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
Who may compete
SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 561621 (security systems services (except locksmiths)), means no more than $25 million in average annual receipts, counted with affiliates. What a set-aside is
What comes next
No solicitation was published under this number after the sources sought of October 11, 2024. An agency sometimes issues the solicitation under a new number.

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov.

Sources Sought Notice Sources Sought Notice Page 6 of 6 Sources Sought Notice *= Required Field Sources Sought Notice Page 1 of 6 This is NOT a solicitation or request for quote (RFQ). This is NOT a request for proposal (RFP). This is NOT a job advertisement for hiring employees. The VA is seeking QUALIFIED VENDORS to provide a very brief response to this notice including only just what is asked for in this notice below.

This is sources sought notice to industry and the only information is posted on Contract Opportunities web page at SAM.gov. Sources sought means seeking qualified vendors. The attachments included on the Contract Opportunities page do not include any additional information. If your company is interested, please read this notice entirely and submit the required information, as requested herein.

Fire suppression system repair, inspection, testing and maintenance at the Rocky Mountain Regional VA Medical Center BRIEF SCOPE OF WORK (This is for information only) Item # Item Amount 1 Fire Suppression System repair and maintenance (Base Year) 1 Year 2 Fire Suppression System repair and maintenance (Option Year 1) 1 Year 3 Fire Suppression System repair and maintenance (Option Year 2) 1 Year 4 Fire Suppression System repair and maintenance (Option Year 3) 1 Year 5 Fire Suppression System repair and maintenance (Option Year 4) 1 Year The United States Department of Veteran Affairs requires services to perform maintenance on the fire sprinkler system at RMR VAMC, 1700 Wheeling Street, Aurora, CO 80045 as required by the NFPA 25 standard.

This work includes Buildings A, B, C, D, E, F, G, H, K, L, P, PE, PN, PS and Fisher House (Bldg. R). Occupied buildings total approximately 1.8 million square feet. The objective is to provide inspection, maintenance & testing services in accordance with referenced codes for the fire sprinkler system of the entire campus, currently 13 buildings and 1.2 million square feet.

1.2a Contractor will perform inspection, testing, maintenance, and replacement of parts associated with all kitchen suppression hoods located at the Rocky Mountain Regional VAMC 1.3 Service work to the fire sprinkler system must be completed in accordance with the following:

NFPA 25; Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems NFPA 13; Installation of Sprinkler Systems NFPA 72; National Fire Alarm Code NFPA 14 Standard for the Installation of Standpipe and Hose Systems, 2013 Edition (Copyright 2013 by National Fire Protection Association Inc.). NFPA 15 Standard for Water Spray Fixed Systems for Fire Protection, 2012 Edition (Copyright 2011 by National Fire Protection Association Inc.).

NFPA 4 Standard for Integrated Fire Protection and Life Safety System Testing 2015 Edition (Copyright 2015 by National Fire Protection Association Inc. Place of Performance: Department of Veterans Affairs Rocky Mountain Regional VAMC 1700 N. Wheeling St Aurora, CO 80045 IMPORTANT NOTE: This Sources Sought is for market research purposes only (to determine the socioeconomic status of interested companies). No award will be made off this posting.

IMPORTANT NOTE: This RFI (Request for Information) is for information only. No award will be made from this RFI.

QUALIFIED VENDOR: A qualified source has the a) necessary equipment, vehicles, personnel, resources and current operations as well as b) recent experience (within past 3 years) of performing services of a comparable size, scope and complexity, AND c) OEM certified technicians to perform services with unrestricted access to the facility during inclement weather, as well as immediate access to OEM software updates.

A qualified source also has current and valid registration in System for Award Management (SAM), https://www.sam.gov). A qualified source will also be able to comply with Limitations of Subcontracting pursuant to FAR 19.507. Please communicate via e-mail to chris.hollingsworth@va.gov by 4:00 PM EST on October 18, 2024 as to your company s ability to perform service per this brief Scope of Work. If interested, please provide the following:

Provide company s capability statement describing ability to provide preventative maintenance services as outlined above Please state your company s business size in relation to above NAICS Code and provide your socio-economic category if applicable Please provide your UEI number If you have an FSS/GSA contract that includes this service Provide FSS/GSA contract number if applicable Indicate whether your company will self-perform services or state whether a third-party service provider will be utilized to provide the required services (note: Limitations on Subcontracting FAR 52.219-14, VAAR 852.219-74, 852.219-75, 852.219-77) If a subcontractor will be utilized, provide their company name, socioeconomic category, and UEI Only written responses, to items 1 through 7 above, will be accepted at this stage.

Information is being gathered for market research purposes only. Industry exchanges and vendor teleconferences are at the discretion of the Contract Specialist. This is not a request for quotes.

DISCLAIMER: This is a Request for Information (RFI) from industry in accordance with Federal Acquisition Regulation (FAR) 15.201(e) and on the requirement, that exists for the VA Medical Center(s) identified in this RFI. This is not a request for quote and not a contract. This announcement is not a request for proposals; therefore, responses to the RFI are not considered offers and cannot be accepted by the Government to form a binding contract.

This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responders are solely responsible for all expenses associated with responding to this RFI. No classified information should be included in the RFI response.

Should you have concerns regarding this RFI you may request to contact the Contracting Office that will be assigned this requirement by emailing the sender of this RFI. Questions must be addressed in writing to the Contract Specialist.

Requests for VA-business sensitive information, to include VA budget information, VA acquisition planning information, acquisition methods, strategies and set-asides must be addressed via the VA FOIA process: https://www.va.gov/foia/ Thank you for your interest in doing business with the VA.

To learn more about the VA Mission, Vision, Core Values & Goals visit https://www.va.gov/about_va/mission.asp To understand the latest updates on the Veterans First Contracting Program visit https://www.va.gov/osdbu/verification/veterans_first_contracting_program_adjustments_to_reflect_the_supreme_court_kingdomware_decision.asp To find out how to do business with the VA visit https://www.va.gov/osdbu/library/dbwva.asp To become a CVE-verified VOSB or SDVOSB visit https://www.vip.vetbiz.va.gov/

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. October 11, 2024

    Sources sought

    Due October 18, 2024 at 4:00 PM EDT. SAM.gov, notice 3cca9d3c6a7d4910af9dd372946b3373

Points of contact