{"canonical":"https://sealedbidder.com/opportunities/36c25726q0707","key":"36C25726Q0707","url":"https://sealedbidder.com/opportunities/36c25726q0707","title":"OPHTHALMOLOGY, REFRACTIVE EQUIPMENT","solicitation_number":"36C25726Q0707","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-08-14T15:00:00Z","first_posted":"2026-07-01","last_posted":"2026-08-10","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"339112","psc":"6515","set_aside":null,"place_state":"TX","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"48029","place_county_name":"Bexar County","place_city":"4865000","place_city_name":"San Antonio","winner":"MELLING LLC","award_amount":null,"publications":[{"notice_id":"b215f206b8774f4aac0739628c5336e9","title":"6540--OPHTHALMOLOGY, REFRACTIVE EQUIPMENT","solicitation_number":"36C25726Q0707","notice_type":"r","base_type":"r","posted":"2026-07-01","posted_at":"2026-07-01T20:10:39.550Z","due_at":"2026-07-07T15:00:00Z","due_date":"2026-07-07","cancelled":false,"archived":true,"archive_date":"2026-09-05","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/b215f206b8774f4aac0739628c5336e9/view","enriched":true,"history":[{"index":3,"title":"6540--OPHTHALMOLOGY, REFRACTIVE EQUIPMENT","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-01T20:23:38.322Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"cf9bfd76db144feb91c4c5027c0beddf","solicitation_number":"36C25726Q0707","parent_opportunity_id":"b215f206b8774f4aac0739628c5336e9"},{"index":1,"title":"6540--OPHTHALMOLOGY, REFRACTIVE EQUIPMENT","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-01T20:10:39.550Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"b215f206b8774f4aac0739628c5336e9","solicitation_number":"36C25726Q0707"}]},{"notice_id":"cf9bfd76db144feb91c4c5027c0beddf","title":"6540--OPHTHALMOLOGY, REFRACTIVE EQUIPMENT","solicitation_number":"36C25726Q0707","notice_type":"r","base_type":"r","posted":"2026-07-01","posted_at":"2026-07-01T20:23:38.322Z","due_at":"2026-07-09T15:00:00Z","due_date":"2026-07-09","cancelled":false,"archived":true,"archive_date":"2026-09-05","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/cf9bfd76db144feb91c4c5027c0beddf/view","enriched":true,"history":[{"index":3,"title":"6540--OPHTHALMOLOGY, REFRACTIVE EQUIPMENT","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-01T20:23:38.322Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"cf9bfd76db144feb91c4c5027c0beddf","solicitation_number":"36C25726Q0707","parent_opportunity_id":"b215f206b8774f4aac0739628c5336e9"},{"index":1,"title":"6540--OPHTHALMOLOGY, REFRACTIVE EQUIPMENT","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-01T20:10:39.550Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"b215f206b8774f4aac0739628c5336e9","solicitation_number":"36C25726Q0707"}]},{"notice_id":"82fbc397f33c4a2aab20c5c7abc3f669","title":"OPHTHALMOLOGY, REFRACTIVE EQUIPMENT","solicitation_number":"36C25726Q0707","notice_type":"k","base_type":"k","posted":"2026-08-10","posted_at":"2026-08-10T21:11:21.815Z","due_at":"2026-08-14T15:00:00Z","due_date":"2026-08-14","cancelled":false,"archived":true,"archive_date":"2026-09-20","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/82fbc397f33c4a2aab20c5c7abc3f669/view","enriched":true,"history":[{"index":2,"title":"OPHTHALMOLOGY, REFRACTIVE EQUIPMENT","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":true,"posted_at":"2026-08-14T14:09:00.288Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"3e0c62b895a84e0a9151f8b5ed00400d","solicitation_number":"36C25726Q0707","parent_opportunity_id":"82fbc397f33c4a2aab20c5c7abc3f669"},{"index":1,"title":"OPHTHALMOLOGY, REFRACTIVE EQUIPMENT","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-10T21:11:21.815Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"82fbc397f33c4a2aab20c5c7abc3f669","solicitation_number":"36C25726Q0707"}]}],"latest_notice_id":"82fbc397f33c4a2aab20c5c7abc3f669","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-07-01","posted_at":"2026-07-01T20:10:39.550Z","created_at":"2026-07-01T20:10:37.257Z","modified_at":"2026-09-05T05:07:53.969Z","response_deadline":{"raw":"2026-07-07T10:00:00-05:00","utc":"2026-07-07T15:00:00Z","date":"2026-07-07","time":"10:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/b215f206b8774f4aac0739628c5336e9/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"6540--OPHTHALMOLOGY, REFRACTIVE EQUIPMENT","agency":{"office":{"code":"36C257","name":"257-NETWORK CONTRACT OFFICE 17 (36C257)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"78240","city":"San Antonio","state":"TX","country":"USA"},"organization_id":"100167100","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-09-05","archive_type":"auto_custom"},"history":[{"index":3,"title":"6540--OPHTHALMOLOGY, REFRACTIVE EQUIPMENT","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-01T20:23:38.322Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"cf9bfd76db144feb91c4c5027c0beddf","solicitation_number":"36C25726Q0707","parent_opportunity_id":"b215f206b8774f4aac0739628c5336e9"},{"index":1,"title":"6540--OPHTHALMOLOGY, REFRACTIVE EQUIPMENT","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-01T20:10:39.550Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"b215f206b8774f4aac0739628c5336e9","solicitation_number":"36C25726Q0707"}],"contacts":[{"name":"Michelle Cunningham","role":"primary","email":"michelle.cunningham@va.gov","phone":"michelle.cunningham@va.gov","title":"Michelle Cunningham"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"b215f206b8774f4aac0739628c5336e9","lineage_id":"b215f206b8774f4aac0739628c5336e9","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-30T13:30:45.466477008Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"9a0045410f1995077bfe67bad818af13b2bda5e4005406c07450c8ffa3e53747","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-30T13:30:45.466477008Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"This market research notice is being conducted by Network Contracting Office (NCO) 17 VHA Regional Procurement Office-West (RPOW) 5441 Babcock Road Medical Center. 302 San Antonio TX 78240 for the procurement for the Ophthalmology, Refraction Equipment for the GI care area for the Fort Sam Houston Veterans Health Care System VA.  TX 78251\nBackground and Requirement:  San Antiona Veteran Healthcare  System , 99339 HWY 151 San Antonio, TX 78229, is seeking the following equipment Ophthalmology, Refraction Equipment. This equipment is necessary for manifest refractions which are a vital diagnostic test for eye exams at NWHCC Eye Clinic. \n   \nNursing Delivery of will be conducted by the contractor at no additional charge to the government. Equipment will be delivered to the  San Antonio VA, 9939 HWY 151 San Antonio, TX 78229. \n\nVendor is responsible for installation, training and instructions and guidance at the service location indicated by the assigned COR. Delivery will occur during normal business hours M-F from 0800 to 1500. Delivery/installation and all communication will be coordinated with the assigned COR.\n\nThe equipment must be new, not refurbished and meet all applicable VA and FDA regulations.\n\n            \nTECHNICAL REQUIREMENTS\n\n\nSTATEMENT OF WORK\n\n       Requirement Title: Ophthalmology, Refraction Equipment\n\nProject Description: The Department of Veterans Affairs (VA) requires the procurement of a phoropter digital Refraction System, digital chart/acuity System, Auto Kerato-Refractometer with Double Top Instrument Table and Auto Lensometer to perform refractions during eye examination. This equipment is necessary for manifest refractions which are a vital diagnostic test for eye exams at NWHCC Eye Clinic. \n\nScope of Work: \n\nDelivery will be conducted by the contractor at no additional charge to the government. Equipment will be delivered to the  San Antonio VA, 9939 HWY 151 San Antonio, TX 78251. \nVendor is responsible for installation, training and instructions and guidance at the service location indicated by the assigned COR. Delivery will occur during normal business hours M-F from 0800 to 1500. Delivery/installation and all communication will be coordinated with the assigned COR.\nThe equipment must be new, not refurbished and meet all applicable VA and FDA regulations.\nEquipment shall include manufacturer installation, assembly, calibration, on-site user training, removal of trash/shipping containers and a minimum one-year manufacturer's warranty covering parts, labor, and technical support.\nThe digital phoropter, autorefractor/keratometer, and lensometer shall operate as an integrated refraction system.\nAll devices must be fully compatible, interoperable, and capable of communicating with each other, such that measurements from the auto refractor and lensometer can be uploaded directly into the digital phoropter to perform manifest refractions without manual entry.\nDevices will not require any patient identifying information to function as a system. \n\nRequirements\nThe digital Phoropter digital refraction system with Prism must meet the following requirements:\n  Phoroptor Head:\nSpherical Effects +17.75 to -22.25 D, Steps : 0.25 and 1.0 DÂ \nCylinder Power-8.0 to +8.0 D, Steps: 0.25 and 1.0 D\nAxis Adjustment 0Â° to 180Â°, Steps : 1Â° and 10Â°\nCross Cylinder TestÂ  Â±0.25 D\nPrismatic Effects 0.20 Prism Diopter per eye Steps:Â 0.50 Prism Diopter per eye 0.25 Prism Diopter per eye\nCorneal Vertex DistanceÂ 16 mm\nPupil DistanceÂ 50 to 80 mm, Steps: 1 mm binocularÂ \nConvergence 400 mm\nHeight Level of Eyes, adjustment Â±3 mm\nLeveling via bubble level\nFree Aperture 19 mm\nThickness of Housing at the Viewing Aperture 26 mm\nWidth x Height x Depth (at PD = 64 mm) 31 x 20.3 x 7.1 cm (12.2 x 8 x 2.8 in.)\nPorts (1 each):Phoroptor, Controller (Keypad),Projector (Acuity System),Printer, Instrument 1 I/O, Instrument 2 I/O,EMR Port, Transfer Port\nErgonomic digital controller with intuitive user interface. \nCapable of storing and recalling multiple examination settings and patient refraction data. \nSupport rapid lens changes for efficient subjective refraction. \nQuiet electronic operation with smooth lens transitions. \nCommunication interfaces (USB, Ethernet, serial, or equivalent) to support integration with other ophthalmic instruments. \nShall electronically receive objective refraction data from an autorefractor. \nÂ·    Shall electronically receive lens measurements from a digital lensometer. \nShall support automated data transfer to facilitate efficient manifest refractions with minimal manual data entry. \nShall be compatible with a digital visual acuity/chart display system.\nEquipment shall include all cables, interface modules, power supplies, software licenses, and accessories necessary for complete installation and operation.\n \nThe digital Chart /Acuity System must meet the following requirements:\nDisplay:Â 24 in. (60 cm) LED backlit LCD (1920x1080 Pixels)\nMax Illumination:Â 220 cd/m2\nPhotopic Illumination:Â 85 cd/m2\nMesopic Illumination:Â 3 cd/m2\nRefraction Range:Â 1.83 m (6 ft) - 7.5 m (24.6 ft)\nAdjustable testing distances from 6 feet (1.83 m) to at least 24 feet (7.5 m) or equivalent optical simulation.\nAdjustable brightness supporting both:\nPhotopic testing \nMesopic testing\nAutomatic scaling of optotypes for selected testing distance.\nRandomized optotype presentations to prevent patient memorization. \nMultiple contrast sensitivity testing capabilities.\nColor vision testing capability.\nBinocular vision and stereoacuity testing capability. \nRed/green balance testing. \nWorth Four Dot testing. \nFixation targets suitable for pediatric examinations. \nSingle-letter, line, column, and isolated optotype presentation. \nProgrammable examination sequences.\nDimensions: Height:Â 39.62 cm (15.60 in) Width:Â 58.92 cm (23.20 in.) Depth:Â 7.62 cm (3.00 in.) Weight:Â (unpacked) 5.9 kg (13.1 lbs.)\nCapable of bidirectional communication with the digital phoropter.\nCommunication: RS232 Serial Port,2 USB Ports. Must be able to be linked by wired or wireless connection to a digital Phoroptor\nRemote Control:Â InfraredÂ \nElectrical:Â Voltage:Â 100 - 240 volts AC 50/60 Hz, Input Power:Â 50-75 VA, Fuses:Â Time-Lag (2.5A, 250V), 5 x 20mm, Remote Control:Â 2 AAA (LR03) batteries\nCompatible with VA-approved ophthalmic diagnostic systems and future interoperability requirements. \nInclude all mounting hardware, cables, power supplies, software, licenses, adapters, and accessories required for complete installation and operation. \nContractor shall provide installation, configuration, calibration, and on-site user training. \n\nAuto Kerato-Refractometer with Instrument Table with Double Top must meet the following requirements:\nMust perform both keratometer and refractometer measurements\nSphere Range: -25D to +22D (0.01D/0.12D/0.25D steps)\nCylinder Range: 0D to Â±10D (0.01D/0.12D/0.25D steps)\nAxis Range: 0Â° to 180Â° (1Â° /5Â°steps)\nMeasurable Area: Ã˜ 8 mm (max.)\nSelectable measurement increments of 0.25 D or finer.\nAutomatic measurement and averaging of multiple readings\nAutomatic fogging function or equivalent accommodation control to improve measurement accuracy\nMeasurable Minimum Pupil Diameter: Ã˜ 2 mm\nCorneal Curvature Radius: 5.00 mm to 10.00 mm (0.01 mm steps)\nCorneal Refraction: 67.5D~33.75D (0.01D/0.12D/0.25D steps)(Proviso: corneal refractive index = 1.3375)\nCorneal Astigmatism: 0D to Â± 10D (0.12D/0.25D steps)\nCorneal Astigmatism Axial Angle: 0Â° to 180Â° (1Â° /5Â°steps)\nMeasurable PD Range:20~85 mm (1 mm step)\nExport Output Terminal: USB (IN/OUT), RS232C (OUT), LAN (IN/OUT)\nElectronically transmit objective refraction measurements directly to the digital phoropter\nSupport automated transfer of objective refractive data to facilitate efficient manifest refractions\nTabletop must be designed to accept any auto kerato-refractometer standard or large ophthalmic instrument.\nMust be able to support 110lbs to ensure smooth movement even with the heaviest device combination.\nBe electrically height adjustable.\nInclude locking casters or equivalent stability features\nInclude all mounting hardware required for installation.\n\n The Auto lensometer requirements:\nMeasurement Range: Sphere: 0 to Â±25 D (0.01/0.12/0.25D steps), Cylinder: 0 to Â±10 D (0.01/0.12/0.25D steps), Axis: 0 to 180Â°(1Â° step), Addition: 0 to Â±10 D (0.01/0.12/0.25D steps), Prism: 0 to 10 \nCylinder Mode: MIX /   / +\nPrism Mode: X-Y (Orthogonal Coordinates), P-B (Polar Coordinates), No Display\nPrism measurement capability of at least 0 to 10 prism diopters.\nUV Transmittance: 0 ~ 100% (1% / 5% steps)\nAutomatic compensation for various lens materials or equivalent measurement technology\nLens Detection: AUTO for single & progressive lenses\nContact Lens Measurement: Hard / Soft contact lens\nSelectable plus, minus, and mixed cylinder display modes.\nAutomatic detection and measurement of single-vision, bifocal, trifocal, and progressive addition lenses.\nLight Source: Refractive Measurement: Green LED 540Â±5nm,UV Measurement: UV LED 365Â±5nm\nSelectable plus, minus, and mixed cylinder display modes.\nWavelength Criterion: e-line/d-line with ABBE compensation\nGreen LED measurement light source or equivalent technology to improve measurement accuracy.\nLens Diameter 5 to 100 mm\nScreen: 5.7-inch color touch screen\nElectronically transmit lens measurement data directly to a compatible digital phoropter.\nSupport automated transfer of lensometry data to facilitate efficient manifest refractions while minimizing manual data entry.\nInclude USB, Ethernet (LAN), RS-232, or equivalent communication interfaces as needed.\nPD Measurement Range: 50-90mm\nThey systems shall include the following accessories:\nStandard Included Accessories Phoropter:\nÂ   Â Â Dust Cover - Phoroptor Head\nÂ   Â Â Dust Cover - Controller\nÂ   Â Â Phoroptor Cable\nÂ   Â Â User s Guide\nÂ   Â Â Decimal Card Holder or Snellen Card Holder\nÂ   Â Â Power Cord 115V or Power Cord 230V\nÂ   Â Â Card Beam Assembly\nÂ   Â Â Card Illuminator\nÂ   Â Â Face Shield Kit (2 sets)\nÂ   Â Â Quick Reference Card\nStandard included accessories for digital chart digital acuity System\nRemote Control  \nTwo AAA batteries \nPower Cords \nArticulating Wall Mount with hardware as needed \nWall Anchor Toggle Bolts Hardware \nColor Glasses\nKey Card for Pigassou Optotypes  \nKey Card for Sheridan Gardiner Optotypes \nInstructions for Use \nWall Mount Bracket Adaptor  \nUSB Bluetooth adapter \nWireless Dongle Kit \nStandard Accessories Auto Kerato-Refractometer with Instrument Table with Double Top \nDust cover(s) \nPower cords \nCommunication cables \nUser manuals \nSoftware licenses (if applicable) \nInstallation materials \nCalibration accessories \nAll components required for complete operation\nStandard Accessories for the Auto Lensometer\nDust cover(s) \nPower cords \nCommunication cables \nUser manuals \nSoftware licenses (if applicable) \nInstallation materials \nCalibration accessories \nAll components required for complete operation\nAll contection components/cords including 100-240V / 50/60Hz 1.2A (AC Adapter), AUTO power save\nWarranty\nThe equipment shall be covered by a minimum one-year manufacturer s warranty\nThe warranty shall include parts, labor and technical support\nThe contractor shall provide details on the process for warranty claims and repairs\nTechnical Support:\nThe contractor shall provide technical support via phone or email during normal business hours\nAny defective or malfunctioning unit shall be repaired or replaced at no additional cost to the VA during the Warranty period. \nAcceptance Criteria: The VA will inspect the equipment delivered to ensure it meets all technical and functional specifications Acceptance will be granted when:\nThe equipment is delivered in good condition\nAll accessories and documentation are included\nInstallation testing successfully competed\nContractor Responsibilities\nEnsure timely Delivery of the required equipment.\nProvide necessary documentation, including user manuals and warranty details.\nEnsure compliance with all applicable VA, FDA and industry standards\nProvide post-installation support as required\n\nInformation System Officer, Information Protection: The contractor will not have access to VA Desktop computers they will not have access to online resources belonging to the government.\n\nPrivacy Officer: The Contractor will not have access to protected Patient Health Information (PHI) nor will they have capability of accessing patient information during the services provided to the VA and if removal of equipment from the VA is required, any memory storage device will remain in VA control and will not be removed from VA custody. All research data available for Contractor analysis is de-identified.\n\n\nRecords Manager: There will not be federal records created, maintained, used or dispositioned with this contract;Â  regardless of format [paper, electronic, etc.] or mode of transmission [e-mail, fax, etc.]\n\n\n  This equipment must be able to perform the following functions for all the SPECIFIC INSTRUMENT REQUIRED: San Antiona Veteran Healthcare  System , 99339 HWY 151 San Antonio, TX 78229, Ophthalmology, Refraction Equipment\n\n\na.  If this is an item your business can provide, please respond to this Sources Sought  Notice by 10:00 AM Central Time on Thursday  9 July  2026.\n\nb. The intent of this notice is to establish sources to define the procurement   strategy (e.g. set-aside, sole source, unrestricted) for a solicitation that VA intends to post soon.Â  Interested contractors are requested to respond in accordance with the following:Â \nÂ \nc. Where is the item manufactured, the VA is interested in procuring items manufactured in the United States. Provide City and State.\n\nd. you have an existing GSA or VA, Federal Supply Schedule contract, include the contract details in your response.\n\ne. Please note that VA is particularly interested in determining the availability of Service Disable Veteran Owned Small Business/Veteran Owned  Small Business or other Small Business manufacturers or authorized distributors that can provide this item.Â \n\nÂ Respond to this notice if you can provide these products listed in the table in the background and requirement section above. In response, please cite your business size status.Â \n\nÂ DISTRIBUTORS:Â  You must provide proof that you are an authorized distributor. VA does not accept gray market items.Â \nÂ \nVendors are requested to submit estimated market research pricing with their responses.Â  The estimated pricing will be considered when determining the procurement strategy for the future solicitation. (e.g., if CO determines that capable small businesses cannot provide fair and reasonable pricing, then the solicitation will not be set-aside).Â Â \nÂ \n                  i.Â Responses should include:  Â \n(1) Business NameÂ \n(2) Business AddressÂ \n(3) Point of ContactÂ Â \n- NameÂ \n- Phone NumberÂ \n- E-mail AddressÂ \n(4) SAM UID NumberÂ \n(5) NAICS codeÂ \n(6) Business Size: SMALL or LARGEÂ \n(7) Type of Business: SERVICE-DISABLED VETERAN OWNED (SDVOSB), VETERAN OWNED(VOSB), 8A, HUBZone, WOMAN-OWNED (WOSB), etc.Â Â \n(8) Letter stating OEM authorized dealer, authorized distributor, or authorized reseller for the proposed equipment and/or services if applicableÂ \n(9) GSA/FSS Contract Number if applicableÂ Â \nÂ \nAll businesses eligible to provide this item are encouraged to reply as this information may be used to determine potential set-asides for the above-noted requirement.Â Â \nÂ \n              8. Send responses to Michelle Cunningham at michelle.cunningham@va.gov.Â Â Â \nÂ \nDISCLAIMER:Â  THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE QUOTES. However, Contractors may submit a capability statement, proposal, or quotation which shall be considered by the contracting officer whether to continue with the sole source procurement or to provide for competition. Due to technical issues, please allow additional time if you re using electronic means.Â \nResponses received will be evaluated; however, a determination by the Government not to compete with the proposed procurement based upon responses received to this notice is solely within the discretion of the Government.Â","text":"This market research notice is being conducted by Network Contracting Office (NCO) 17 VHA Regional Procurement Office-West (RPOW) 5441 Babcock Road Medical Center. 302 San Antonio TX 78240 for the procurement for the Ophthalmology, Refraction Equipment for the GI care area for the Fort Sam Houston Veterans Health Care System VA. TX 78251\nBackground and Requirement: San Antiona Veteran Healthcare System , 99339 HWY 151 San Antonio, TX 78229, is seeking the following equipment Ophthalmology, Refraction Equipment. This equipment is necessary for manifest refractions which are a vital diagnostic test for eye exams at NWHCC Eye Clinic.\n\nNursing Delivery of will be conducted by the contractor at no additional charge to the government. Equipment will be delivered to the San Antonio VA, 9939 HWY 151 San Antonio, TX 78229.\n\nVendor is responsible for installation, training and instructions and guidance at the service location indicated by the assigned COR. Delivery will occur during normal business hours M-F from 0800 to 1500. Delivery/installation and all communication will be coordinated with the assigned COR.\n\nThe equipment must be new, not refurbished and meet all applicable VA and FDA regulations.\n\nTECHNICAL REQUIREMENTS\n\nSTATEMENT OF WORK\n\nRequirement Title: Ophthalmology, Refraction Equipment\n\nProject Description: The Department of Veterans Affairs (VA) requires the procurement of a phoropter digital Refraction System, digital chart/acuity System, Auto Kerato-Refractometer with Double Top Instrument Table and Auto Lensometer to perform refractions during eye examination. This equipment is necessary for manifest refractions which are a vital diagnostic test for eye exams at NWHCC Eye Clinic.\n\nScope of Work:\n\nDelivery will be conducted by the contractor at no additional charge to the government. Equipment will be delivered to the San Antonio VA, 9939 HWY 151 San Antonio, TX 78251.\nVendor is responsible for installation, training and instructions and guidance at the service location indicated by the assigned COR. Delivery will occur during normal business hours M-F from 0800 to 1500. Delivery/installation and all communication will be coordinated with the assigned COR.\nThe equipment must be new, not refurbished and meet all applicable VA and FDA regulations.\nEquipment shall include manufacturer installation, assembly, calibration, on-site user training, removal of trash/shipping containers and a minimum one-year manufacturer's warranty covering parts, labor, and technical support.\nThe digital phoropter, autorefractor/keratometer, and lensometer shall operate as an integrated refraction system.\nAll devices must be fully compatible, interoperable, and capable of communicating with each other, such that measurements from the auto refractor and lensometer can be uploaded directly into the digital phoropter to perform manifest refractions without manual entry.\nDevices will not require any patient identifying information to function as a system.\n\nRequirements\nThe digital Phoropter digital refraction system with Prism must meet the following requirements:\nPhoroptor Head:\nSpherical Effects +17.75 to -22.25 D, Steps : 0.25 and 1.0 DÂ\nCylinder Power-8.0 to +8.0 D, Steps: 0.25 and 1.0 D\nAxis Adjustment 0Â° to 180Â°, Steps : 1Â° and 10Â°\nCross Cylinder TestÂ Â±0.25 D\nPrismatic Effects 0.20 Prism Diopter per eye Steps:Â 0.50 Prism Diopter per eye 0.25 Prism Diopter per eye\nCorneal Vertex DistanceÂ 16 mm\nPupil DistanceÂ 50 to 80 mm, Steps: 1 mm binocularÂ\nConvergence 400 mm\nHeight Level of Eyes, adjustment Â±3 mm\nLeveling via bubble level\nFree Aperture 19 mm\nThickness of Housing at the Viewing Aperture 26 mm\nWidth x Height x Depth (at PD = 64 mm) 31 x 20.3 x 7.1 cm (12.2 x 8 x 2.8 in.)\nPorts (1 each):Phoroptor, Controller (Keypad),Projector (Acuity System),Printer, Instrument 1 I/O, Instrument 2 I/O,EMR Port, Transfer Port\nErgonomic digital controller with intuitive user interface.\nCapable of storing and recalling multiple examination settings and patient refraction data.\nSupport rapid lens changes for efficient subjective refraction.\nQuiet electronic operation with smooth lens transitions.\nCommunication interfaces (USB, Ethernet, serial, or equivalent) to support integration with other ophthalmic instruments.\nShall electronically receive objective refraction data from an autorefractor.\nÂ· Shall electronically receive lens measurements from a digital lensometer.\nShall support automated data transfer to facilitate efficient manifest refractions with minimal manual data entry.\nShall be compatible with a digital visual acuity/chart display system.\nEquipment shall include all cables, interface modules, power supplies, software licenses, and accessories necessary for complete installation and operation.\n\nThe digital Chart /Acuity System must meet the following requirements:\nDisplay:Â 24 in. (60 cm) LED backlit LCD (1920x1080 Pixels)\nMax Illumination:Â 220 cd/m2\nPhotopic Illumination:Â 85 cd/m2\nMesopic Illumination:Â 3 cd/m2\nRefraction Range:Â 1.83 m (6 ft) - 7.5 m (24.6 ft)\nAdjustable testing distances from 6 feet (1.83 m) to at least 24 feet (7.5 m) or equivalent optical simulation.\nAdjustable brightness supporting both:\nPhotopic testing\nMesopic testing\nAutomatic scaling of optotypes for selected testing distance.\nRandomized optotype presentations to prevent patient memorization.\nMultiple contrast sensitivity testing capabilities.\nColor vision testing capability.\nBinocular vision and stereoacuity testing capability.\nRed/green balance testing.\nWorth Four Dot testing.\nFixation targets suitable for pediatric examinations.\nSingle-letter, line, column, and isolated optotype presentation.\nProgrammable examination sequences.\nDimensions: Height:Â 39.62 cm (15.60 in) Width:Â 58.92 cm (23.20 in.) Depth:Â 7.62 cm (3.00 in.) Weight:Â (unpacked) 5.9 kg (13.1 lbs.)\nCapable of bidirectional communication with the digital phoropter.\nCommunication: RS232 Serial Port,2 USB Ports. Must be able to be linked by wired or wireless connection to a digital Phoroptor\nRemote Control:Â InfraredÂ\nElectrical:Â Voltage:Â 100 - 240 volts AC 50/60 Hz, Input Power:Â 50-75 VA, Fuses:Â Time-Lag (2.5A, 250V), 5 x 20mm, Remote Control:Â 2 AAA (LR03) batteries\nCompatible with VA-approved ophthalmic diagnostic systems and future interoperability requirements.\nInclude all mounting hardware, cables, power supplies, software, licenses, adapters, and accessories required for complete installation and operation.\nContractor shall provide installation, configuration, calibration, and on-site user training.\n\nAuto Kerato-Refractometer with Instrument Table with Double Top must meet the following requirements:\nMust perform both keratometer and refractometer measurements\nSphere Range: -25D to +22D (0.01D/0.12D/0.25D steps)\nCylinder Range: 0D to Â±10D (0.01D/0.12D/0.25D steps)\nAxis Range: 0Â° to 180Â° (1Â° /5Â°steps)\nMeasurable Area: Ã˜ 8 mm (max.)\nSelectable measurement increments of 0.25 D or finer.\nAutomatic measurement and averaging of multiple readings\nAutomatic fogging function or equivalent accommodation control to improve measurement accuracy\nMeasurable Minimum Pupil Diameter: Ã˜ 2 mm\nCorneal Curvature Radius: 5.00 mm to 10.00 mm (0.01 mm steps)\nCorneal Refraction: 67.5D~33.75D (0.01D/0.12D/0.25D steps)(Proviso: corneal refractive index = 1.3375)\nCorneal Astigmatism: 0D to Â± 10D (0.12D/0.25D steps)\nCorneal Astigmatism Axial Angle: 0Â° to 180Â° (1Â° /5Â°steps)\nMeasurable PD Range:20~85 mm (1 mm step)\nExport Output Terminal: USB (IN/OUT), RS232C (OUT), LAN (IN/OUT)\nElectronically transmit objective refraction measurements directly to the digital phoropter\nSupport automated transfer of objective refractive data to facilitate efficient manifest refractions\nTabletop must be designed to accept any auto kerato-refractometer standard or large ophthalmic instrument.\nMust be able to support 110lbs to ensure smooth movement even with the heaviest device combination.\nBe electrically height adjustable.\nInclude locking casters or equivalent stability features\nInclude all mounting hardware required for installation.\n\nThe Auto lensometer requirements:\nMeasurement Range: Sphere: 0 to Â±25 D (0.01/0.12/0.25D steps), Cylinder: 0 to Â±10 D (0.01/0.12/0.25D steps), Axis: 0 to 180Â°(1Â° step), Addition: 0 to Â±10 D (0.01/0.12/0.25D steps), Prism: 0 to 10\nCylinder Mode: MIX / / +\nPrism Mode: X-Y (Orthogonal Coordinates), P-B (Polar Coordinates), No Display\nPrism measurement capability of at least 0 to 10 prism diopters.\nUV Transmittance: 0 ~ 100% (1% / 5% steps)\nAutomatic compensation for various lens materials or equivalent measurement technology\nLens Detection: AUTO for single & progressive lenses\nContact Lens Measurement: Hard / Soft contact lens\nSelectable plus, minus, and mixed cylinder display modes.\nAutomatic detection and measurement of single-vision, bifocal, trifocal, and progressive addition lenses.\nLight Source: Refractive Measurement: Green LED 540Â±5nm,UV Measurement: UV LED 365Â±5nm\nSelectable plus, minus, and mixed cylinder display modes.\nWavelength Criterion: e-line/d-line with ABBE compensation\nGreen LED measurement light source or equivalent technology to improve measurement accuracy.\nLens Diameter 5 to 100 mm\nScreen: 5.7-inch color touch screen\nElectronically transmit lens measurement data directly to a compatible digital phoropter.\nSupport automated transfer of lensometry data to facilitate efficient manifest refractions while minimizing manual data entry.\nInclude USB, Ethernet (LAN), RS-232, or equivalent communication interfaces as needed.\nPD Measurement Range: 50-90mm\nThey systems shall include the following accessories:\nStandard Included Accessories Phoropter:\nÂ Â Â Dust Cover - Phoroptor Head\nÂ Â Â Dust Cover - Controller\nÂ Â Â Phoroptor Cable\nÂ Â Â User s Guide\nÂ Â Â Decimal Card Holder or Snellen Card Holder\nÂ Â Â Power Cord 115V or Power Cord 230V\nÂ Â Â Card Beam Assembly\nÂ Â Â Card Illuminator\nÂ Â Â Face Shield Kit (2 sets)\nÂ Â Â Quick Reference Card\nStandard included accessories for digital chart digital acuity System\nRemote Control\nTwo AAA batteries\nPower Cords\nArticulating Wall Mount with hardware as needed\nWall Anchor Toggle Bolts Hardware\nColor Glasses\nKey Card for Pigassou Optotypes\nKey Card for Sheridan Gardiner Optotypes\nInstructions for Use\nWall Mount Bracket Adaptor\nUSB Bluetooth adapter\nWireless Dongle Kit\nStandard Accessories Auto Kerato-Refractometer with Instrument Table with Double Top\nDust cover(s)\nPower cords\nCommunication cables\nUser manuals\nSoftware licenses (if applicable)\nInstallation materials\nCalibration accessories\nAll components required for complete operation\nStandard Accessories for the Auto Lensometer\nDust cover(s)\nPower cords\nCommunication cables\nUser manuals\nSoftware licenses (if applicable)\nInstallation materials\nCalibration accessories\nAll components required for complete operation\nAll contection components/cords including 100-240V / 50/60Hz 1.2A (AC Adapter), AUTO power save\nWarranty\nThe equipment shall be covered by a minimum one-year manufacturer s warranty\nThe warranty shall include parts, labor and technical support\nThe contractor shall provide details on the process for warranty claims and repairs\nTechnical Support:\nThe contractor shall provide technical support via phone or email during normal business hours\nAny defective or malfunctioning unit shall be repaired or replaced at no additional cost to the VA during the Warranty period.\nAcceptance Criteria: The VA will inspect the equipment delivered to ensure it meets all technical and functional specifications Acceptance will be granted when:\nThe equipment is delivered in good condition\nAll accessories and documentation are included\nInstallation testing successfully competed\nContractor Responsibilities\nEnsure timely Delivery of the required equipment.\nProvide necessary documentation, including user manuals and warranty details.\nEnsure compliance with all applicable VA, FDA and industry standards\nProvide post-installation support as required\n\nInformation System Officer, Information Protection: The contractor will not have access to VA Desktop computers they will not have access to online resources belonging to the government.\n\nPrivacy Officer: The Contractor will not have access to protected Patient Health Information (PHI) nor will they have capability of accessing patient information during the services provided to the VA and if removal of equipment from the VA is required, any memory storage device will remain in VA control and will not be removed from VA custody. All research data available for Contractor analysis is de-identified.\n\nRecords Manager: There will not be federal records created, maintained, used or dispositioned with this contract;Â regardless of format [paper, electronic, etc.] or mode of transmission [e-mail, fax, etc.]\n\nThis equipment must be able to perform the following functions for all the SPECIFIC INSTRUMENT REQUIRED: San Antiona Veteran Healthcare System , 99339 HWY 151 San Antonio, TX 78229, Ophthalmology, Refraction Equipment\n\na. If this is an item your business can provide, please respond to this Sources Sought Notice by 10:00 AM Central Time on Thursday 9 July 2026.\n\nb. The intent of this notice is to establish sources to define the procurement strategy (e.g. set-aside, sole source, unrestricted) for a solicitation that VA intends to post soon.Â Interested contractors are requested to respond in accordance with the following:Â\nÂ\nc. Where is the item manufactured, the VA is interested in procuring items manufactured in the United States. Provide City and State.\n\nd. you have an existing GSA or VA, Federal Supply Schedule contract, include the contract details in your response.\n\ne. Please note that VA is particularly interested in determining the availability of Service Disable Veteran Owned Small Business/Veteran Owned Small Business or other Small Business manufacturers or authorized distributors that can provide this item.Â\n\nÂ Respond to this notice if you can provide these products listed in the table in the background and requirement section above. In response, please cite your business size status.Â\n\nÂ DISTRIBUTORS:Â You must provide proof that you are an authorized distributor. VA does not accept gray market items.Â\nÂ\nVendors are requested to submit estimated market research pricing with their responses.Â The estimated pricing will be considered when determining the procurement strategy for the future solicitation. (e.g., if CO determines that capable small businesses cannot provide fair and reasonable pricing, then the solicitation will not be set-aside).Â Â\nÂ\ni.Â Responses should include: Â\n(1) Business NameÂ\n(2) Business AddressÂ\n(3) Point of ContactÂ Â\n- NameÂ\n- Phone NumberÂ\n- E-mail AddressÂ\n(4) SAM UID NumberÂ\n(5) NAICS codeÂ\n(6) Business Size: SMALL or LARGEÂ\n(7) Type of Business: SERVICE-DISABLED VETERAN OWNED (SDVOSB), VETERAN OWNED(VOSB), 8A, HUBZone, WOMAN-OWNED (WOSB), etc.Â Â\n(8) Letter stating OEM authorized dealer, authorized distributor, or authorized reseller for the proposed equipment and/or services if applicableÂ\n(9) GSA/FSS Contract Number if applicableÂ Â\nÂ\nAll businesses eligible to provide this item are encouraged to reply as this information may be used to determine potential set-asides for the above-noted requirement.Â Â\nÂ\n8. Send responses to Michelle Cunningham at michelle.cunningham@va.gov.Â Â Â\nÂ\nDISCLAIMER:Â THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE QUOTES. However, Contractors may submit a capability statement, proposal, or quotation which shall be considered by the contracting officer whether to continue with the sole source procurement or to provide for competition. Due to technical issues, please allow additional time if you re using electronic means.Â\nResponses received will be evaluated; however, a determination by the Government not to compete with the proposed procurement based upon responses received to this notice is solely within the discretion of the Government.Â","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25726Q0707","place_of_performance":{"zip":"78229","city":{"code":"65000","name":"San Antonio"},"state":{"code":"TX","name":"Texas"},"street":"San Antonio Veteran Health Care System 99339 HWY 151","country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6540"},{"award":{"awardee":{}},"dates":{"posted":"2026-07-01","posted_at":"2026-07-01T20:23:38.322Z","created_at":"2026-07-01T20:23:14.894Z","modified_at":"2026-09-05T05:07:53.969Z","response_deadline":{"raw":"2026-07-09T10:00:00-05:00","utc":"2026-07-09T15:00:00Z","date":"2026-07-09","time":"10:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/cf9bfd76db144feb91c4c5027c0beddf/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"6540--OPHTHALMOLOGY, REFRACTIVE EQUIPMENT","agency":{"office":{"code":"36C257","name":"257-NETWORK CONTRACT OFFICE 17 (36C257)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"78240","city":"San Antonio","state":"TX","country":"USA"},"organization_id":"100167100","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-09-05","archive_type":"auto_custom"},"history":[{"index":3,"title":"6540--OPHTHALMOLOGY, REFRACTIVE EQUIPMENT","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-01T20:23:38.322Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"cf9bfd76db144feb91c4c5027c0beddf","solicitation_number":"36C25726Q0707","parent_opportunity_id":"b215f206b8774f4aac0739628c5336e9"},{"index":1,"title":"6540--OPHTHALMOLOGY, REFRACTIVE EQUIPMENT","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-01T20:10:39.550Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"b215f206b8774f4aac0739628c5336e9","solicitation_number":"36C25726Q0707"}],"contacts":[{"name":"Michelle Cunningham","role":"primary","email":"michelle.cunningham@va.gov","phone":"michelle.cunningham@va.gov","title":"Michelle Cunningham"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"cf9bfd76db144feb91c4c5027c0beddf","lineage_id":"b215f206b8774f4aac0739628c5336e9","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-30T13:39:08.946078846Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"677f2fc5ed027b8b08af121694d4241ccb68731cebfb7d8abfd958048c13f983","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-30T13:39:08.946078846Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"This market research notice is being conducted by Network Contracting Office (NCO) 17 VHA Regional Procurement Office-West (RPOW) 5441 Babcock Road Medical Center. 302 San Antonio TX 78240 for the procurement for the Ophthalmology, Refraction Equipment for the GI care area for the Fort Sam Houston Veterans Health Care System VA.  TX 78251\nBackground and Requirement:  San Antiona Veteran Healthcare  System , 99339 HWY 151 San Antonio, TX 78229, is seeking the following equipment Ophthalmology, Refraction Equipment. This equipment is necessary for manifest refractions which are a vital diagnostic test for eye exams at NWHCC Eye Clinic. \n   \nNursing Delivery of will be conducted by the contractor at no additional charge to the government. Equipment will be delivered to the  San Antonio VA, 9939 HWY 151 San Antonio, TX 78229. \n\nVendor is responsible for installation, training and instructions and guidance at the service location indicated by the assigned COR. Delivery will occur during normal business hours M-F from 0800 to 1500. Delivery/installation and all communication will be coordinated with the assigned COR.\n\nThe equipment must be new, not refurbished and meet all applicable VA and FDA regulations.\n\n            \nTECHNICAL REQUIREMENTS\n\n\nSTATEMENT OF WORK\n\n       Requirement Title: Ophthalmology, Refraction Equipment\n\nProject Description: The Department of Veterans Affairs (VA) requires the procurement of a phoropter digital Refraction System, digital chart/acuity System, Auto Kerato-Refractometer with Double Top Instrument Table and Auto Lensometer to perform refractions during eye examination. This equipment is necessary for manifest refractions which are a vital diagnostic test for eye exams at NWHCC Eye Clinic. \n\nScope of Work: \n\nDelivery will be conducted by the contractor at no additional charge to the government. Equipment will be delivered to the  San Antonio VA, 9939 HWY 151 San Antonio, TX 78251. \nVendor is responsible for installation, training and instructions and guidance at the service location indicated by the assigned COR. Delivery will occur during normal business hours M-F from 0800 to 1500. Delivery/installation and all communication will be coordinated with the assigned COR.\nThe equipment must be new, not refurbished and meet all applicable VA and FDA regulations.\nEquipment shall include manufacturer installation, assembly, calibration, on-site user training, removal of trash/shipping containers and a minimum one-year manufacturer's warranty covering parts, labor, and technical support.\nThe digital phoropter, autorefractor/keratometer, and lensometer shall operate as an integrated refraction system.\nAll devices must be fully compatible, interoperable, and capable of communicating with each other, such that measurements from the auto refractor and lensometer can be uploaded directly into the digital phoropter to perform manifest refractions without manual entry.\nDevices will not require any patient identifying information to function as a system. \n\nRequirements\nThe digital Phoropter digital refraction system with Prism must meet the following requirements:\n  Phoroptor Head:\nSpherical Effects +17.75 to -22.25 D, Steps : 0.25 and 1.0 DÂ \nCylinder Power-8.0 to +8.0 D, Steps: 0.25 and 1.0 D\nAxis Adjustment 0Â° to 180Â°, Steps : 1Â° and 10Â°\nCross Cylinder TestÂ  Â±0.25 D\nPrismatic Effects 0.20 Prism Diopter per eye Steps:Â 0.50 Prism Diopter per eye 0.25 Prism Diopter per eye\nCorneal Vertex DistanceÂ 16 mm\nPupil DistanceÂ 50 to 80 mm, Steps: 1 mm binocularÂ \nConvergence 400 mm\nHeight Level of Eyes, adjustment Â±3 mm\nLeveling via bubble level\nFree Aperture 19 mm\nThickness of Housing at the Viewing Aperture 26 mm\nWidth x Height x Depth (at PD = 64 mm) 31 x 20.3 x 7.1 cm (12.2 x 8 x 2.8 in.)\nPorts (1 each):Phoroptor, Controller (Keypad),Projector (Acuity System),Printer, Instrument 1 I/O, Instrument 2 I/O,EMR Port, Transfer Port\nErgonomic digital controller with intuitive user interface. \nCapable of storing and recalling multiple examination settings and patient refraction data. \nSupport rapid lens changes for efficient subjective refraction. \nQuiet electronic operation with smooth lens transitions. \nCommunication interfaces (USB, Ethernet, serial, or equivalent) to support integration with other ophthalmic instruments. \nShall electronically receive objective refraction data from an autorefractor. \nÂ·    Shall electronically receive lens measurements from a digital lensometer. \nShall support automated data transfer to facilitate efficient manifest refractions with minimal manual data entry. \nShall be compatible with a digital visual acuity/chart display system.\nEquipment shall include all cables, interface modules, power supplies, software licenses, and accessories necessary for complete installation and operation.\n \nThe digital Chart /Acuity System must meet the following requirements:\nDisplay:Â 24 in. (60 cm) LED backlit LCD (1920x1080 Pixels)\nMax Illumination:Â 220 cd/m2\nPhotopic Illumination:Â 85 cd/m2\nMesopic Illumination:Â 3 cd/m2\nRefraction Range:Â 1.83 m (6 ft) - 7.5 m (24.6 ft)\nAdjustable testing distances from 6 feet (1.83 m) to at least 24 feet (7.5 m) or equivalent optical simulation.\nAdjustable brightness supporting both:\nPhotopic testing \nMesopic testing\nAutomatic scaling of optotypes for selected testing distance.\nRandomized optotype presentations to prevent patient memorization. \nMultiple contrast sensitivity testing capabilities.\nColor vision testing capability.\nBinocular vision and stereoacuity testing capability. \nRed/green balance testing. \nWorth Four Dot testing. \nFixation targets suitable for pediatric examinations. \nSingle-letter, line, column, and isolated optotype presentation. \nProgrammable examination sequences.\nDimensions: Height:Â 39.62 cm (15.60 in) Width:Â 58.92 cm (23.20 in.) Depth:Â 7.62 cm (3.00 in.) Weight:Â (unpacked) 5.9 kg (13.1 lbs.)\nCapable of bidirectional communication with the digital phoropter.\nCommunication: RS232 Serial Port,2 USB Ports. Must be able to be linked by wired or wireless connection to a digital Phoroptor\nRemote Control:Â InfraredÂ \nElectrical:Â Voltage:Â 100 - 240 volts AC 50/60 Hz, Input Power:Â 50-75 VA, Fuses:Â Time-Lag (2.5A, 250V), 5 x 20mm, Remote Control:Â 2 AAA (LR03) batteries\nCompatible with VA-approved ophthalmic diagnostic systems and future interoperability requirements. \nInclude all mounting hardware, cables, power supplies, software, licenses, adapters, and accessories required for complete installation and operation. \nContractor shall provide installation, configuration, calibration, and on-site user training. \n\nAuto Kerato-Refractometer with Instrument Table with Double Top must meet the following requirements:\nMust perform both keratometer and refractometer measurements\nSphere Range: -25D to +22D (0.01D/0.12D/0.25D steps)\nCylinder Range: 0D to Â±10D (0.01D/0.12D/0.25D steps)\nAxis Range: 0Â° to 180Â° (1Â° /5Â°steps)\nMeasurable Area: Ã˜ 8 mm (max.)\nSelectable measurement increments of 0.25 D or finer.\nAutomatic measurement and averaging of multiple readings\nAutomatic fogging function or equivalent accommodation control to improve measurement accuracy\nMeasurable Minimum Pupil Diameter: Ã˜ 2 mm\nCorneal Curvature Radius: 5.00 mm to 10.00 mm (0.01 mm steps)\nCorneal Refraction: 67.5D~33.75D (0.01D/0.12D/0.25D steps)(Proviso: corneal refractive index = 1.3375)\nCorneal Astigmatism: 0D to Â± 10D (0.12D/0.25D steps)\nCorneal Astigmatism Axial Angle: 0Â° to 180Â° (1Â° /5Â°steps)\nMeasurable PD Range:20~85 mm (1 mm step)\nExport Output Terminal: USB (IN/OUT), RS232C (OUT), LAN (IN/OUT)\nElectronically transmit objective refraction measurements directly to the digital phoropter\nSupport automated transfer of objective refractive data to facilitate efficient manifest refractions\nTabletop must be designed to accept any auto kerato-refractometer standard or large ophthalmic instrument.\nMust be able to support 110lbs to ensure smooth movement even with the heaviest device combination.\nBe electrically height adjustable.\nInclude locking casters or equivalent stability features\nInclude all mounting hardware required for installation.\n\n The Auto lensometer requirements:\nMeasurement Range: Sphere: 0 to Â±25 D (0.01/0.12/0.25D steps), Cylinder: 0 to Â±10 D (0.01/0.12/0.25D steps), Axis: 0 to 180Â°(1Â° step), Addition: 0 to Â±10 D (0.01/0.12/0.25D steps), Prism: 0 to 10 \nCylinder Mode: MIX /   / +\nPrism Mode: X-Y (Orthogonal Coordinates), P-B (Polar Coordinates), No Display\nPrism measurement capability of at least 0 to 10 prism diopters.\nUV Transmittance: 0 ~ 100% (1% / 5% steps)\nAutomatic compensation for various lens materials or equivalent measurement technology\nLens Detection: AUTO for single & progressive lenses\nContact Lens Measurement: Hard / Soft contact lens\nSelectable plus, minus, and mixed cylinder display modes.\nAutomatic detection and measurement of single-vision, bifocal, trifocal, and progressive addition lenses.\nLight Source: Refractive Measurement: Green LED 540Â±5nm,UV Measurement: UV LED 365Â±5nm\nSelectable plus, minus, and mixed cylinder display modes.\nWavelength Criterion: e-line/d-line with ABBE compensation\nGreen LED measurement light source or equivalent technology to improve measurement accuracy.\nLens Diameter 5 to 100 mm\nScreen: 5.7-inch color touch screen\nElectronically transmit lens measurement data directly to a compatible digital phoropter.\nSupport automated transfer of lensometry data to facilitate efficient manifest refractions while minimizing manual data entry.\nInclude USB, Ethernet (LAN), RS-232, or equivalent communication interfaces as needed.\nPD Measurement Range: 50-90mm\nThey systems shall include the following accessories:\nStandard Included Accessories Phoropter:\nÂ   Â Â Dust Cover - Phoroptor Head\nÂ   Â Â Dust Cover - Controller\nÂ   Â Â Phoroptor Cable\nÂ   Â Â User s Guide\nÂ   Â Â Decimal Card Holder or Snellen Card Holder\nÂ   Â Â Power Cord 115V or Power Cord 230V\nÂ   Â Â Card Beam Assembly\nÂ   Â Â Card Illuminator\nÂ   Â Â Face Shield Kit (2 sets)\nÂ   Â Â Quick Reference Card\nStandard included accessories for digital chart digital acuity System\nRemote Control  \nTwo AAA batteries \nPower Cords \nArticulating Wall Mount with hardware as needed \nWall Anchor Toggle Bolts Hardware \nColor Glasses\nKey Card for Pigassou Optotypes  \nKey Card for Sheridan Gardiner Optotypes \nInstructions for Use \nWall Mount Bracket Adaptor  \nUSB Bluetooth adapter \nWireless Dongle Kit \nStandard Accessories Auto Kerato-Refractometer with Instrument Table with Double Top \nDust cover(s) \nPower cords \nCommunication cables \nUser manuals \nSoftware licenses (if applicable) \nInstallation materials \nCalibration accessories \nAll components required for complete operation\nStandard Accessories for the Auto Lensometer\nDust cover(s) \nPower cords \nCommunication cables \nUser manuals \nSoftware licenses (if applicable) \nInstallation materials \nCalibration accessories \nAll components required for complete operation\nAll contection components/cords including 100-240V / 50/60Hz 1.2A (AC Adapter), AUTO power save\nWarranty\nThe equipment shall be covered by a minimum one-year manufacturer s warranty\nThe warranty shall include parts, labor and technical support\nThe contractor shall provide details on the process for warranty claims and repairs\nTechnical Support:\nThe contractor shall provide technical support via phone or email during normal business hours\nAny defective or malfunctioning unit shall be repaired or replaced at no additional cost to the VA during the Warranty period. \nAcceptance Criteria: The VA will inspect the equipment delivered to ensure it meets all technical and functional specifications Acceptance will be granted when:\nThe equipment is delivered in good condition\nAll accessories and documentation are included\nInstallation testing successfully competed\nContractor Responsibilities\nEnsure timely Delivery of the required equipment.\nProvide necessary documentation, including user manuals and warranty details.\nEnsure compliance with all applicable VA, FDA and industry standards\nProvide post-installation support as required\n\nInformation System Officer, Information Protection: The contractor will not have access to VA Desktop computers they will not have access to online resources belonging to the government.\n\nPrivacy Officer: The Contractor will not have access to protected Patient Health Information (PHI) nor will they have capability of accessing patient information during the services provided to the VA and if removal of equipment from the VA is required, any memory storage device will remain in VA control and will not be removed from VA custody. All research data available for Contractor analysis is de-identified.\n\n\nRecords Manager: There will not be federal records created, maintained, used or dispositioned with this contract;Â  regardless of format [paper, electronic, etc.] or mode of transmission [e-mail, fax, etc.]\n\n\n  This equipment must be able to perform the following functions for all the SPECIFIC INSTRUMENT REQUIRED: San Antiona Veteran Healthcare  System , 99339 HWY 151 San Antonio, TX 78229, Ophthalmology, Refraction Equipment\n\n\na.  If this is an item your business can provide, please respond to this Sources Sought  Notice by 10:00 AM Central Time on Thursday  9 July  2026.\n\nb. The intent of this notice is to establish sources to define the procurement   strategy (e.g. set-aside, sole source, unrestricted) for a solicitation that VA intends to post soon.Â  Interested contractors are requested to respond in accordance with the following:Â \nÂ \nc. Where is the item manufactured, the VA is interested in procuring items manufactured in the United States. Provide City and State.\n\nd. you have an existing GSA or VA, Federal Supply Schedule contract, include the contract details in your response.\n\ne. Please note that VA is particularly interested in determining the availability of Service Disable Veteran Owned Small Business/Veteran Owned  Small Business or other Small Business manufacturers or authorized distributors that can provide this item.Â \n\nÂ Respond to this notice if you can provide these products listed in the table in the background and requirement section above. In response, please cite your business size status.Â \n\nÂ DISTRIBUTORS:Â  You must provide proof that you are an authorized distributor. VA does not accept gray market items.Â \nÂ \nVendors are requested to submit estimated market research pricing with their responses.Â  The estimated pricing will be considered when determining the procurement strategy for the future solicitation. (e.g., if CO determines that capable small businesses cannot provide fair and reasonable pricing, then the solicitation will not be set-aside).Â Â \nÂ \n                  i.Â Responses should include:  Â \n(1) Business NameÂ \n(2) Business AddressÂ \n(3) Point of ContactÂ Â \n- NameÂ \n- Phone NumberÂ \n- E-mail AddressÂ \n(4) SAM UID NumberÂ \n(5) NAICS codeÂ \n(6) Business Size: SMALL or LARGEÂ \n(7) Type of Business: SERVICE-DISABLED VETERAN OWNED (SDVOSB), VETERAN OWNED(VOSB), 8A, HUBZone, WOMAN-OWNED (WOSB), etc.Â Â \n(8) Letter stating OEM authorized dealer, authorized distributor, or authorized reseller for the proposed equipment and/or services if applicableÂ \n(9) GSA/FSS Contract Number if applicableÂ Â \nÂ \nAll businesses eligible to provide this item are encouraged to reply as this information may be used to determine potential set-asides for the above-noted requirement.Â Â \nÂ \n              8. Send responses to Michelle Cunningham at michelle.cunningham@va.gov.Â Â Â \nÂ \nDISCLAIMER:Â  THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE QUOTES. However, Contractors may submit a capability statement, proposal, or quotation which shall be considered by the contracting officer whether to continue with the sole source procurement or to provide for competition. Due to technical issues, please allow additional time if you re using electronic means.Â \nResponses received will be evaluated; however, a determination by the Government not to compete with the proposed procurement based upon responses received to this notice is solely within the discretion of the Government.Â","text":"This market research notice is being conducted by Network Contracting Office (NCO) 17 VHA Regional Procurement Office-West (RPOW) 5441 Babcock Road Medical Center. 302 San Antonio TX 78240 for the procurement for the Ophthalmology, Refraction Equipment for the GI care area for the Fort Sam Houston Veterans Health Care System VA. TX 78251\nBackground and Requirement: San Antiona Veteran Healthcare System , 99339 HWY 151 San Antonio, TX 78229, is seeking the following equipment Ophthalmology, Refraction Equipment. This equipment is necessary for manifest refractions which are a vital diagnostic test for eye exams at NWHCC Eye Clinic.\n\nNursing Delivery of will be conducted by the contractor at no additional charge to the government. Equipment will be delivered to the San Antonio VA, 9939 HWY 151 San Antonio, TX 78229.\n\nVendor is responsible for installation, training and instructions and guidance at the service location indicated by the assigned COR. Delivery will occur during normal business hours M-F from 0800 to 1500. Delivery/installation and all communication will be coordinated with the assigned COR.\n\nThe equipment must be new, not refurbished and meet all applicable VA and FDA regulations.\n\nTECHNICAL REQUIREMENTS\n\nSTATEMENT OF WORK\n\nRequirement Title: Ophthalmology, Refraction Equipment\n\nProject Description: The Department of Veterans Affairs (VA) requires the procurement of a phoropter digital Refraction System, digital chart/acuity System, Auto Kerato-Refractometer with Double Top Instrument Table and Auto Lensometer to perform refractions during eye examination. This equipment is necessary for manifest refractions which are a vital diagnostic test for eye exams at NWHCC Eye Clinic.\n\nScope of Work:\n\nDelivery will be conducted by the contractor at no additional charge to the government. Equipment will be delivered to the San Antonio VA, 9939 HWY 151 San Antonio, TX 78251.\nVendor is responsible for installation, training and instructions and guidance at the service location indicated by the assigned COR. Delivery will occur during normal business hours M-F from 0800 to 1500. Delivery/installation and all communication will be coordinated with the assigned COR.\nThe equipment must be new, not refurbished and meet all applicable VA and FDA regulations.\nEquipment shall include manufacturer installation, assembly, calibration, on-site user training, removal of trash/shipping containers and a minimum one-year manufacturer's warranty covering parts, labor, and technical support.\nThe digital phoropter, autorefractor/keratometer, and lensometer shall operate as an integrated refraction system.\nAll devices must be fully compatible, interoperable, and capable of communicating with each other, such that measurements from the auto refractor and lensometer can be uploaded directly into the digital phoropter to perform manifest refractions without manual entry.\nDevices will not require any patient identifying information to function as a system.\n\nRequirements\nThe digital Phoropter digital refraction system with Prism must meet the following requirements:\nPhoroptor Head:\nSpherical Effects +17.75 to -22.25 D, Steps : 0.25 and 1.0 DÂ\nCylinder Power-8.0 to +8.0 D, Steps: 0.25 and 1.0 D\nAxis Adjustment 0Â° to 180Â°, Steps : 1Â° and 10Â°\nCross Cylinder TestÂ Â±0.25 D\nPrismatic Effects 0.20 Prism Diopter per eye Steps:Â 0.50 Prism Diopter per eye 0.25 Prism Diopter per eye\nCorneal Vertex DistanceÂ 16 mm\nPupil DistanceÂ 50 to 80 mm, Steps: 1 mm binocularÂ\nConvergence 400 mm\nHeight Level of Eyes, adjustment Â±3 mm\nLeveling via bubble level\nFree Aperture 19 mm\nThickness of Housing at the Viewing Aperture 26 mm\nWidth x Height x Depth (at PD = 64 mm) 31 x 20.3 x 7.1 cm (12.2 x 8 x 2.8 in.)\nPorts (1 each):Phoroptor, Controller (Keypad),Projector (Acuity System),Printer, Instrument 1 I/O, Instrument 2 I/O,EMR Port, Transfer Port\nErgonomic digital controller with intuitive user interface.\nCapable of storing and recalling multiple examination settings and patient refraction data.\nSupport rapid lens changes for efficient subjective refraction.\nQuiet electronic operation with smooth lens transitions.\nCommunication interfaces (USB, Ethernet, serial, or equivalent) to support integration with other ophthalmic instruments.\nShall electronically receive objective refraction data from an autorefractor.\nÂ· Shall electronically receive lens measurements from a digital lensometer.\nShall support automated data transfer to facilitate efficient manifest refractions with minimal manual data entry.\nShall be compatible with a digital visual acuity/chart display system.\nEquipment shall include all cables, interface modules, power supplies, software licenses, and accessories necessary for complete installation and operation.\n\nThe digital Chart /Acuity System must meet the following requirements:\nDisplay:Â 24 in. (60 cm) LED backlit LCD (1920x1080 Pixels)\nMax Illumination:Â 220 cd/m2\nPhotopic Illumination:Â 85 cd/m2\nMesopic Illumination:Â 3 cd/m2\nRefraction Range:Â 1.83 m (6 ft) - 7.5 m (24.6 ft)\nAdjustable testing distances from 6 feet (1.83 m) to at least 24 feet (7.5 m) or equivalent optical simulation.\nAdjustable brightness supporting both:\nPhotopic testing\nMesopic testing\nAutomatic scaling of optotypes for selected testing distance.\nRandomized optotype presentations to prevent patient memorization.\nMultiple contrast sensitivity testing capabilities.\nColor vision testing capability.\nBinocular vision and stereoacuity testing capability.\nRed/green balance testing.\nWorth Four Dot testing.\nFixation targets suitable for pediatric examinations.\nSingle-letter, line, column, and isolated optotype presentation.\nProgrammable examination sequences.\nDimensions: Height:Â 39.62 cm (15.60 in) Width:Â 58.92 cm (23.20 in.) Depth:Â 7.62 cm (3.00 in.) Weight:Â (unpacked) 5.9 kg (13.1 lbs.)\nCapable of bidirectional communication with the digital phoropter.\nCommunication: RS232 Serial Port,2 USB Ports. Must be able to be linked by wired or wireless connection to a digital Phoroptor\nRemote Control:Â InfraredÂ\nElectrical:Â Voltage:Â 100 - 240 volts AC 50/60 Hz, Input Power:Â 50-75 VA, Fuses:Â Time-Lag (2.5A, 250V), 5 x 20mm, Remote Control:Â 2 AAA (LR03) batteries\nCompatible with VA-approved ophthalmic diagnostic systems and future interoperability requirements.\nInclude all mounting hardware, cables, power supplies, software, licenses, adapters, and accessories required for complete installation and operation.\nContractor shall provide installation, configuration, calibration, and on-site user training.\n\nAuto Kerato-Refractometer with Instrument Table with Double Top must meet the following requirements:\nMust perform both keratometer and refractometer measurements\nSphere Range: -25D to +22D (0.01D/0.12D/0.25D steps)\nCylinder Range: 0D to Â±10D (0.01D/0.12D/0.25D steps)\nAxis Range: 0Â° to 180Â° (1Â° /5Â°steps)\nMeasurable Area: Ã˜ 8 mm (max.)\nSelectable measurement increments of 0.25 D or finer.\nAutomatic measurement and averaging of multiple readings\nAutomatic fogging function or equivalent accommodation control to improve measurement accuracy\nMeasurable Minimum Pupil Diameter: Ã˜ 2 mm\nCorneal Curvature Radius: 5.00 mm to 10.00 mm (0.01 mm steps)\nCorneal Refraction: 67.5D~33.75D (0.01D/0.12D/0.25D steps)(Proviso: corneal refractive index = 1.3375)\nCorneal Astigmatism: 0D to Â± 10D (0.12D/0.25D steps)\nCorneal Astigmatism Axial Angle: 0Â° to 180Â° (1Â° /5Â°steps)\nMeasurable PD Range:20~85 mm (1 mm step)\nExport Output Terminal: USB (IN/OUT), RS232C (OUT), LAN (IN/OUT)\nElectronically transmit objective refraction measurements directly to the digital phoropter\nSupport automated transfer of objective refractive data to facilitate efficient manifest refractions\nTabletop must be designed to accept any auto kerato-refractometer standard or large ophthalmic instrument.\nMust be able to support 110lbs to ensure smooth movement even with the heaviest device combination.\nBe electrically height adjustable.\nInclude locking casters or equivalent stability features\nInclude all mounting hardware required for installation.\n\nThe Auto lensometer requirements:\nMeasurement Range: Sphere: 0 to Â±25 D (0.01/0.12/0.25D steps), Cylinder: 0 to Â±10 D (0.01/0.12/0.25D steps), Axis: 0 to 180Â°(1Â° step), Addition: 0 to Â±10 D (0.01/0.12/0.25D steps), Prism: 0 to 10\nCylinder Mode: MIX / / +\nPrism Mode: X-Y (Orthogonal Coordinates), P-B (Polar Coordinates), No Display\nPrism measurement capability of at least 0 to 10 prism diopters.\nUV Transmittance: 0 ~ 100% (1% / 5% steps)\nAutomatic compensation for various lens materials or equivalent measurement technology\nLens Detection: AUTO for single & progressive lenses\nContact Lens Measurement: Hard / Soft contact lens\nSelectable plus, minus, and mixed cylinder display modes.\nAutomatic detection and measurement of single-vision, bifocal, trifocal, and progressive addition lenses.\nLight Source: Refractive Measurement: Green LED 540Â±5nm,UV Measurement: UV LED 365Â±5nm\nSelectable plus, minus, and mixed cylinder display modes.\nWavelength Criterion: e-line/d-line with ABBE compensation\nGreen LED measurement light source or equivalent technology to improve measurement accuracy.\nLens Diameter 5 to 100 mm\nScreen: 5.7-inch color touch screen\nElectronically transmit lens measurement data directly to a compatible digital phoropter.\nSupport automated transfer of lensometry data to facilitate efficient manifest refractions while minimizing manual data entry.\nInclude USB, Ethernet (LAN), RS-232, or equivalent communication interfaces as needed.\nPD Measurement Range: 50-90mm\nThey systems shall include the following accessories:\nStandard Included Accessories Phoropter:\nÂ Â Â Dust Cover - Phoroptor Head\nÂ Â Â Dust Cover - Controller\nÂ Â Â Phoroptor Cable\nÂ Â Â User s Guide\nÂ Â Â Decimal Card Holder or Snellen Card Holder\nÂ Â Â Power Cord 115V or Power Cord 230V\nÂ Â Â Card Beam Assembly\nÂ Â Â Card Illuminator\nÂ Â Â Face Shield Kit (2 sets)\nÂ Â Â Quick Reference Card\nStandard included accessories for digital chart digital acuity System\nRemote Control\nTwo AAA batteries\nPower Cords\nArticulating Wall Mount with hardware as needed\nWall Anchor Toggle Bolts Hardware\nColor Glasses\nKey Card for Pigassou Optotypes\nKey Card for Sheridan Gardiner Optotypes\nInstructions for Use\nWall Mount Bracket Adaptor\nUSB Bluetooth adapter\nWireless Dongle Kit\nStandard Accessories Auto Kerato-Refractometer with Instrument Table with Double Top\nDust cover(s)\nPower cords\nCommunication cables\nUser manuals\nSoftware licenses (if applicable)\nInstallation materials\nCalibration accessories\nAll components required for complete operation\nStandard Accessories for the Auto Lensometer\nDust cover(s)\nPower cords\nCommunication cables\nUser manuals\nSoftware licenses (if applicable)\nInstallation materials\nCalibration accessories\nAll components required for complete operation\nAll contection components/cords including 100-240V / 50/60Hz 1.2A (AC Adapter), AUTO power save\nWarranty\nThe equipment shall be covered by a minimum one-year manufacturer s warranty\nThe warranty shall include parts, labor and technical support\nThe contractor shall provide details on the process for warranty claims and repairs\nTechnical Support:\nThe contractor shall provide technical support via phone or email during normal business hours\nAny defective or malfunctioning unit shall be repaired or replaced at no additional cost to the VA during the Warranty period.\nAcceptance Criteria: The VA will inspect the equipment delivered to ensure it meets all technical and functional specifications Acceptance will be granted when:\nThe equipment is delivered in good condition\nAll accessories and documentation are included\nInstallation testing successfully competed\nContractor Responsibilities\nEnsure timely Delivery of the required equipment.\nProvide necessary documentation, including user manuals and warranty details.\nEnsure compliance with all applicable VA, FDA and industry standards\nProvide post-installation support as required\n\nInformation System Officer, Information Protection: The contractor will not have access to VA Desktop computers they will not have access to online resources belonging to the government.\n\nPrivacy Officer: The Contractor will not have access to protected Patient Health Information (PHI) nor will they have capability of accessing patient information during the services provided to the VA and if removal of equipment from the VA is required, any memory storage device will remain in VA control and will not be removed from VA custody. All research data available for Contractor analysis is de-identified.\n\nRecords Manager: There will not be federal records created, maintained, used or dispositioned with this contract;Â regardless of format [paper, electronic, etc.] or mode of transmission [e-mail, fax, etc.]\n\nThis equipment must be able to perform the following functions for all the SPECIFIC INSTRUMENT REQUIRED: San Antiona Veteran Healthcare System , 99339 HWY 151 San Antonio, TX 78229, Ophthalmology, Refraction Equipment\n\na. If this is an item your business can provide, please respond to this Sources Sought Notice by 10:00 AM Central Time on Thursday 9 July 2026.\n\nb. The intent of this notice is to establish sources to define the procurement strategy (e.g. set-aside, sole source, unrestricted) for a solicitation that VA intends to post soon.Â Interested contractors are requested to respond in accordance with the following:Â\nÂ\nc. Where is the item manufactured, the VA is interested in procuring items manufactured in the United States. Provide City and State.\n\nd. you have an existing GSA or VA, Federal Supply Schedule contract, include the contract details in your response.\n\ne. Please note that VA is particularly interested in determining the availability of Service Disable Veteran Owned Small Business/Veteran Owned Small Business or other Small Business manufacturers or authorized distributors that can provide this item.Â\n\nÂ Respond to this notice if you can provide these products listed in the table in the background and requirement section above. In response, please cite your business size status.Â\n\nÂ DISTRIBUTORS:Â You must provide proof that you are an authorized distributor. VA does not accept gray market items.Â\nÂ\nVendors are requested to submit estimated market research pricing with their responses.Â The estimated pricing will be considered when determining the procurement strategy for the future solicitation. (e.g., if CO determines that capable small businesses cannot provide fair and reasonable pricing, then the solicitation will not be set-aside).Â Â\nÂ\ni.Â Responses should include: Â\n(1) Business NameÂ\n(2) Business AddressÂ\n(3) Point of ContactÂ Â\n- NameÂ\n- Phone NumberÂ\n- E-mail AddressÂ\n(4) SAM UID NumberÂ\n(5) NAICS codeÂ\n(6) Business Size: SMALL or LARGEÂ\n(7) Type of Business: SERVICE-DISABLED VETERAN OWNED (SDVOSB), VETERAN OWNED(VOSB), 8A, HUBZone, WOMAN-OWNED (WOSB), etc.Â Â\n(8) Letter stating OEM authorized dealer, authorized distributor, or authorized reseller for the proposed equipment and/or services if applicableÂ\n(9) GSA/FSS Contract Number if applicableÂ Â\nÂ\nAll businesses eligible to provide this item are encouraged to reply as this information may be used to determine potential set-asides for the above-noted requirement.Â Â\nÂ\n8. Send responses to Michelle Cunningham at michelle.cunningham@va.gov.Â Â Â\nÂ\nDISCLAIMER:Â THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE QUOTES. However, Contractors may submit a capability statement, proposal, or quotation which shall be considered by the contracting officer whether to continue with the sole source procurement or to provide for competition. Due to technical issues, please allow additional time if you re using electronic means.Â\nResponses received will be evaluated; however, a determination by the Government not to compete with the proposed procurement based upon responses received to this notice is solely within the discretion of the Government.Â","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25726Q0707","place_of_performance":{"zip":"78229","city":{"code":"65000","name":"San Antonio"},"state":{"code":"TX","name":"Texas"},"street":"San Antonio Veteran Health Care System 99339 HWY 151","country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6540"},{"dates":{"posted":"2026-08-10","posted_at":"2026-08-10T21:11:21.815Z","created_at":"2026-08-10T19:50:09.731Z","modified_at":"2026-08-14T14:09:00.288Z","response_deadline":{"raw":"2026-08-14T10:00:00-05:00","utc":"2026-08-14T15:00:00Z","date":"2026-08-14","time":"10:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/82fbc397f33c4a2aab20c5c7abc3f669/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"OPHTHALMOLOGY, REFRACTIVE EQUIPMENT","agency":{"office":{"code":"36C257","name":"257-NETWORK CONTRACT OFFICE 17 (36C257)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"78240","city":"San Antonio","state":"TX","country":"USA"},"organization_id":"100167100","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-09-20","archive_type":"auto_custom"},"history":[{"index":2,"title":"OPHTHALMOLOGY, REFRACTIVE EQUIPMENT","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":true,"posted_at":"2026-08-14T14:09:00.288Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"3e0c62b895a84e0a9151f8b5ed00400d","solicitation_number":"36C25726Q0707","parent_opportunity_id":"82fbc397f33c4a2aab20c5c7abc3f669"},{"index":1,"title":"OPHTHALMOLOGY, REFRACTIVE EQUIPMENT","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-10T21:11:21.815Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"82fbc397f33c4a2aab20c5c7abc3f669","solicitation_number":"36C25726Q0707"}],"contacts":[{"name":"Michelle Cunningham","role":"primary","email":"michelle.cunningham@va.gov"},{"name":"Francisco J Mendoza","role":"secondary","email":"Francisco.Mendoza@va.gov"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"82fbc397f33c4a2aab20c5c7abc3f669","lineage_id":"82fbc397f33c4a2aab20c5c7abc3f669","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-25T02:45:36.540638206Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"420fee0632256c0a4ffb587a09187d2c0055238234f5c00b8ed30f754d764730","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-25T02:45:36.540638206Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>OPHTHALMOLOGY, REFRACTIVE EQUIPMENT</p>","text":"OPHTHALMOLOGY, REFRACTIVE EQUIPMENT","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C25726Q0707","place_of_performance":{"zip":"78229","city":{"code":"65000","name":"San Antonio"},"state":{"code":"TX","name":"Texas"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6515"}],"due_at":"2026-08-14T15:00:00Z","due_date":"2026-08-14","closes_at":"2026-08-14T15:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","state":"TX","county":"48029","county_name":"Bexar County","city":"4865000","city_name":"San Antonio","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"CA7CDKQND7U9","amount":null,"linked_awards":3,"cancelled":false,"archived":true,"updated_at":"2026-09-25T03:40:37.123716Z","principal_notice_id":"82fbc397f33c4a2aab20c5c7abc3f669","description":{"text":"OPHTHALMOLOGY, REFRACTIVE EQUIPMENT","html":"<p>OPHTHALMOLOGY, REFRACTIVE EQUIPMENT</p>","origin":"detail"},"contacts":[{"name":"Michelle Cunningham","role":"primary","email":"michelle.cunningham@va.gov"},{"name":"Francisco J Mendoza","role":"secondary","email":"Francisco.Mendoza@va.gov"}],"place_of_performance":{"zip":"78229","city":{"code":"65000","name":"San Antonio"},"state":{"code":"TX","name":"Texas"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"78240","city":"San Antonio","state":"TX","country":"USA"},"naics_codes":["339112"],"award":null,"attachments":[{"resource_id":"1681cfffa1f44e09adde3e68a2d04328","name":"va.gov","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2026-07-01T20:10:39.550Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov/","mirrored":false},{"resource_id":"89ddeedd9f8c4e6bb8bdda57e4b9b295","name":"S02 36C25726Q0707 v2.pdf","kind":"file","mime_type":".pdf","size_bytes":456923,"posted_at":"2026-08-10T21:11:21.815Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/89ddeedd9f8c4e6bb8bdda57e4b9b295/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C25726N0533_3600_36F79722D0189_3600","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C25726N0533_3600_36F79722D0189_3600/","piid":"36C25726N0533","parent_piid":"36F79722D0189","award_type":"DELIVERY ORDER","vendor_key":"CA7CDKQND7U9","recipient_name":"MELLING LLC","recipient_uei":"CA7CDKQND7U9","recipient_cage":"6XD62","recipient_city":"ALEXANDRIA","recipient_state":"VA","sub_name":"Department of Veterans Affairs","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","office_key":"o-36C257","first_action_date":"2026-09-10","last_action_date":"2026-09-10","actions":1,"obligated":"16292.38","current_total_value":"16292.38","potential_total_value":"16292.38","naics":"339112","psc":"6515","extent_competed":"FULL AND OPEN COMPETITION","set_aside":null,"offers_received":1,"description":"EO 14398 TOPCON RIL","method":"solicitation","confidence":"high","evidence":["solicitation number 36C25726Q0707 equals the FPDS solicitation identifier","same awarding office 36C257"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C25727R0012","latest_notice_id":"1e9cdf40734c4926bc09cfc12390022b","title":"V225--Amarillo and Big Springs Air Ambulance","solicitation_number":"36C25727R0012","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"621910","psc":"V225","set_aside":"SDVOSBC","state":"TX","county":"48375","county_name":"Potter County","city":"4803000","city_name":"Amarillo","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C25727Q0027","latest_notice_id":"0d1de2b7c20d45b99cb735b3d4beccd3","title":"WTX Elevator Inspections and Load Testing Services - Amended","solicitation_number":"36C25727Q0027","notice_type":"k","first_type":"k","first_posted":"2026-10-19","last_posted":"2026-11-20","notices":4,"due_at":"2026-11-30T19:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"238290","psc":"J039","set_aside":"SDVOSBC","state":"TX","county":"48227","county_name":"Howard County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C25727Q0104","latest_notice_id":"9c3ddb4326164d4fa71ad956d4194f7c","title":"6515--36C257-27-AP-0953 Prosthetic STX 671 O2 Equipment (VA-27-00016458)","solicitation_number":"36C25727Q0104","notice_type":"o","first_type":"p","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":3,"due_at":"2026-11-30T19:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"339113","psc":"6515","set_aside":"SDVOSBC","state":"TX","county":"48029","county_name":"Bexar County","city":"4865000","city_name":"San Antonio","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C25727Q00310002","latest_notice_id":"c463c6aa97b7496d99268a3c961117de","title":"NTX Elevator Inspection - Amendment","solicitation_number":"36C25727Q0031-0002","notice_type":"k","first_type":"k","first_posted":"2026-11-04","last_posted":"2026-11-04","notices":1,"due_at":"2026-11-30T21:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"541350","psc":"J036","set_aside":"SDVOSBC","state":"TX","county":"48113","county_name":"Dallas County","city":"4819000","city_name":"Dallas","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-05T04:36:35.392694Z"},{"key":"36C25727Q0052","latest_notice_id":"366f45568a854b0cad0c51cb35650156","title":"Sit-to-Stand Lift","solicitation_number":"36C25727Q0052","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"339112","psc":"6515","set_aside":null,"state":"TX","county":null,"county_name":null,"city":"4819000","city_name":"Dallas","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"36C25727Q0052","latest_notice_id":"366f45568a854b0cad0c51cb35650156","title":"Sit-to-Stand Lift","solicitation_number":"36C25727Q0052","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"339112","psc":"6515","set_aside":null,"state":"TX","county":null,"county_name":null,"city":"4819000","city_name":"Dallas","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"W911S227U0200","latest_notice_id":"153aef7d00e740188276deb8422a2297","title":"Automated External Defibrillator (AED)","solicitation_number":"W911S227U0200","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T20:15:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:15:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24727Q0119","latest_notice_id":"81776fecabf149c9867d6253acdc2478","title":"Vivarium Tunnel Washer","solicitation_number":"36C24727Q0119","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"339112","psc":"6640","set_aside":null,"state":"GA","county":"13089","county_name":"DeKalb County","city":"1322052","city_name":"Decatur","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":16,"indexable":false}