{"canonical":"https://sealedbidder.com/opportunities/36c25725q0799","key":"36C25725Q0799","url":"https://sealedbidder.com/opportunities/36c25725q0799","title":"6540--Sources Sought -Ellex EasyRet Photocoagulator","solicitation_number":"36C25725Q0799","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-07-29T15:00:00Z","first_posted":"2025-07-25","last_posted":"2025-07-25","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"334510","psc":"6540","set_aside":"SBA","place_state":"TX","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"48029","place_county_name":"Bexar County","place_city":"4865000","place_city_name":"San Antonio","winner":null,"award_amount":null,"publications":[{"notice_id":"fa77e002e95644b495c92c11d13bd64b","title":"6540--Sources Sought -Ellex EasyRet Photocoagulator","solicitation_number":"36C25725Q0799","notice_type":"r","base_type":"r","posted":"2025-07-25","posted_at":"2025-07-25T16:29:22.559Z","due_at":"2025-07-29T15:00:00Z","due_date":"2025-07-29","cancelled":false,"archived":true,"archive_date":"2025-08-28","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/fa77e002e95644b495c92c11d13bd64b/view","enriched":true,"history":[{"index":3,"title":"6540--Sources Sought -Ellex EasyRet Photocoagulator","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-25T16:29:22.559Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"fa77e002e95644b495c92c11d13bd64b","solicitation_number":"36C25725Q0799"}]}],"latest_notice_id":"fa77e002e95644b495c92c11d13bd64b","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-07-25","posted_at":"2025-07-25T16:29:22.559Z","created_at":"2025-07-25T16:29:20.300Z","modified_at":"2025-08-29T04:04:37.364Z","response_deadline":{"raw":"2025-07-29T10:00:00-05:00","utc":"2025-07-29T15:00:00Z","date":"2025-07-29","time":"10:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/fa77e002e95644b495c92c11d13bd64b/view"},"naics":{"codes":["334510"],"primary":"334510"},"title":"6540--Sources Sought -Ellex EasyRet Photocoagulator","agency":{"office":{"code":"36C257","name":"257-NETWORK CONTRACT OFFICE 17 (36C257)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"78240","city":"San Antonio","state":"TX","country":"USA"},"organization_id":"100167100","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-08-28","archive_type":"auto_custom"},"history":[{"index":3,"title":"6540--Sources Sought -Ellex EasyRet Photocoagulator","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-25T16:29:22.559Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"fa77e002e95644b495c92c11d13bd64b","solicitation_number":"36C25725Q0799"}],"contacts":[{"name":"Janice Malbon","role":"primary","email":"janice.malbon@va.gov","phone":"(210) 694-6340","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"fa77e002e95644b495c92c11d13bd64b","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"fa77e002e95644b495c92c11d13bd64b","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-08T02:06:38.074394231Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"34a7f628cb13c3a98be4420ffdb4f484962cf1025e5b09180a6b202fe25c6c3d","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-08T02:06:38.074394231Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"The Department of Veterans Affairs (VA), Veterans Health Administration, Veterans Integrated Service Network 17, Network Contracting Office (NCO) 17 is seeking sources for the following procurement:\nBrand Name or equal laser and the DPC Eye service that provides emergency laser treatment for patients that are referred from the emergency department at South Texas Veterans Healthcare System in San Antonio, Texas.\nSalient Characteristics\nOcculight visible yellow laser system 577 nm IQ 577): Provide wireless foot pedal to activate apply laser treatment to the patient.\nCustomize patterns for the treatment size. \nAdjust the Pulse duration time.\nDual External monitors to view the retina to view live images during treatment.  \nAbility to import images in order map.\nSingle and multi-spot pattern delivery using standard continuous-wave or mircopulse treatment modes. \nMulti-spot pattern scanning for efficient pan retinal photocoagulation. \nStandard photocoagulation with optimized wavelengths \n Aiming beam: diode laser, 635 nm nominal \n Patterns: grid (2X2   7X 7) Circle, triple arc. \n Pattern spacing confluent (zero), 1-,2-,3-spot spacing in 0.25 diameter increments. \nSlit lamp style with table BQ or brand is acceptable that can withstand wear and tear by training program. \nContinuous zoom magnification. \nAdjustable eye pieces. \nFilter to protect user. \nBQ 900 Slit Lamp acceptable. \nAdapter coupled to the iridex IQ 577. \nControls thermal elevation by  chopping  a continuous-wave (CW) beam into an envelope of repetitive short pulses allowing the tissue to cool between pulses and reduce thermal buildup. \nFovea-friendly for retinal disorders.\nArgon laser \nLaser energy source: frequency-doubled solid state and direct diode \nMaximum power: 2000mW \nExposure duration: MicroPulse: 10-3000 ms \nExposure internal: CW-Pulse: 1.00-10.00ms \nMicropulse duration: Micropulse: 0.05-1.00ms \nMicropulse interval: 1.00-10.00 ms \nMicropulse duty cycle: preset selections of 5% , 10% , and 15 % \n(continuously adjustable from 0.4%-50%)         \nAiming beam: diode laser, 635 nm nominal \nUser interface: touch-screen & Knobs \nSpot sizes: single spot: 50 um, 100um, 200um, 300 um, 500 um \nSpot sizes; multi spot: 100um, 200um, 300um, 500um \nElectrical: 100-240 VAC, 50/60 Hz \n\nStandard Warranty\nThe products shall be covered by vendor s standard warranty terms and provisions, provided, however that the warranty coverage shall be no less than the following: 5 years\nThe Vendor shall provide a warranty certificate/form stating the warranty period, terms, and information required to initiate the warranty minimal 5 years. \nThe warranty period set forth therein shall run for one year following the first day of use at NWHCC/DPC eye service. \nThe vendor shall extend such warranty directly to the customer as if such customer had purchased the Products directly from the vendor;\nThe vendor shall warrant the products against defects in material and workmanship under normal use and service, repair or replace at vendor s cost any defective Product (or issue a credit or refund, as the case may be, based on the purchase price paid, therefore. \nThe vendor shall pay (or refund the amount of) all freight and shipping charges for any defective Products returned under this paragraph.\n\nDelivery \n7400 Merton Minter San Antonio Texas 78229\n\nDelivery Schedule 0800-1600\n\nSite address (installation) \n8410 Datapoint Drive San Antonio Texas 78229 second floor Eye clinic. \n9939 State Highway 151 San Antonio Texas 78251 first floor Eye clinic.\nRequired delivery as soon as possible within 1-3 weeks.  \nThe vendor is required to manage and coordinate installation at the VA NWHCC with the VA POC- Ray Reil or Jennifer Hampton. \nIf during the performance of this contract, work will be carried out on VA NWHCC/Datapoint  premises, the vendor shall perform all work in such a manner that will cause a minimum interference with VA NWHCC/Datapoint operations and the operations of other contractors on the premises.\nThe vendor shall communicate through the VA POC any required coordination requirements with the General Construction contractor prior to and during delivery and installation activities.\nThe project may be an active construction site during delivery and installation. The vendor shall take all necessary precautions to protect the premises and all persons and property therein from damage or injury. The vendor shall assume responsibility for taking precautions for the vendor's (and associated subcontractors ) employees, agents, licensees, and permittees. The vendor shall abide by any safety requirements imposed by the GC (e.g. hard hats, safety vests).\nTraining Is Required\nThe vendor shall coordinate through the VA POC to provide a hands-on training session to staff selected by the VA. Training shall be completed within 45 days after final installation of equipment.  The vendor will record the training and provide a electronic copy of the training to the VA POC for VA to use to train additional personal at a future date. In addition, the vendor \nshall provide additional training documents to the VA POC for training additional persons at a future date.\nClean Up and Disposal\nThere are limited used to dumpsters on site.\nThe removal of waste and/or excess material shall be conducted through the loading dock area. Delivery trucks and/or other vendor vehicles will not be permitted to remain at the loading dock. Vehicles will need to be brought back to the dock if required to remove any waste, tools, or excess materials.\nPlace of Performance\n8410 Datapoint Drive San Antonio Texas 78229 second floor Eye clinic. \n9939 State Highway 151 San Antonio Texas 78251 first floor Eye clinic.\n\nNCO 17 is seeking sources that have the capability of providing these services. Firms that can provide these services are encouraged to respond to the sources sought notice by contacting the point of contact. Capable firms must respond to the POC no later than 10AM CST on July 29, 2025, to be considered.  Interested firms must identify their company name, SAM UEI number, socioeconomic category, and are asked to provide a capabilities statement with their response. \nThis notice is NOT a formal request for quote or proposals.  No formal solicitation document exists currently.  The information in this notice is for information and planning purposes only and is not to be construed as a commitment by the government.  No contract will be awarded from this notice. The acquisition strategy will be decided based on responses and other market research efforts. If parties choose to respond, any cost associated with preparation and submission of data or cost incurred in response to this announcement shall be the sole responsibility of the contractor and will not be reimbursed by the Government.\nNotice: DO NOT respond to this notice in the Interested Vendors List. Interested firms must respond directly to Janice Malbon, Contract Specialist at: Janice.Malbon@va.gov.","text":"The Department of Veterans Affairs (VA), Veterans Health Administration, Veterans Integrated Service Network 17, Network Contracting Office (NCO) 17 is seeking sources for the following procurement:\nBrand Name or equal laser and the DPC Eye service that provides emergency laser treatment for patients that are referred from the emergency department at South Texas Veterans Healthcare System in San Antonio, Texas.\nSalient Characteristics\nOcculight visible yellow laser system 577 nm IQ 577): Provide wireless foot pedal to activate apply laser treatment to the patient.\nCustomize patterns for the treatment size.\nAdjust the Pulse duration time.\nDual External monitors to view the retina to view live images during treatment.\nAbility to import images in order map.\nSingle and multi-spot pattern delivery using standard continuous-wave or mircopulse treatment modes.\nMulti-spot pattern scanning for efficient pan retinal photocoagulation.\nStandard photocoagulation with optimized wavelengths\nAiming beam: diode laser, 635 nm nominal\nPatterns: grid (2X2 7X 7) Circle, triple arc.\nPattern spacing confluent (zero), 1-,2-,3-spot spacing in 0.25 diameter increments.\nSlit lamp style with table BQ or brand is acceptable that can withstand wear and tear by training program.\nContinuous zoom magnification.\nAdjustable eye pieces.\nFilter to protect user.\nBQ 900 Slit Lamp acceptable.\nAdapter coupled to the iridex IQ 577.\nControls thermal elevation by chopping a continuous-wave (CW) beam into an envelope of repetitive short pulses allowing the tissue to cool between pulses and reduce thermal buildup.\nFovea-friendly for retinal disorders.\nArgon laser\nLaser energy source: frequency-doubled solid state and direct diode\nMaximum power: 2000mW\nExposure duration: MicroPulse: 10-3000 ms\nExposure internal: CW-Pulse: 1.00-10.00ms\nMicropulse duration: Micropulse: 0.05-1.00ms\nMicropulse interval: 1.00-10.00 ms\nMicropulse duty cycle: preset selections of 5% , 10% , and 15 %\n(continuously adjustable from 0.4%-50%)\nAiming beam: diode laser, 635 nm nominal\nUser interface: touch-screen & Knobs\nSpot sizes: single spot: 50 um, 100um, 200um, 300 um, 500 um\nSpot sizes; multi spot: 100um, 200um, 300um, 500um\nElectrical: 100-240 VAC, 50/60 Hz\n\nStandard Warranty\nThe products shall be covered by vendor s standard warranty terms and provisions, provided, however that the warranty coverage shall be no less than the following: 5 years\nThe Vendor shall provide a warranty certificate/form stating the warranty period, terms, and information required to initiate the warranty minimal 5 years.\nThe warranty period set forth therein shall run for one year following the first day of use at NWHCC/DPC eye service.\nThe vendor shall extend such warranty directly to the customer as if such customer had purchased the Products directly from the vendor;\nThe vendor shall warrant the products against defects in material and workmanship under normal use and service, repair or replace at vendor s cost any defective Product (or issue a credit or refund, as the case may be, based on the purchase price paid, therefore.\nThe vendor shall pay (or refund the amount of) all freight and shipping charges for any defective Products returned under this paragraph.\n\nDelivery\n7400 Merton Minter San Antonio Texas 78229\n\nDelivery Schedule 0800-1600\n\nSite address (installation)\n8410 Datapoint Drive San Antonio Texas 78229 second floor Eye clinic.\n9939 State Highway 151 San Antonio Texas 78251 first floor Eye clinic.\nRequired delivery as soon as possible within 1-3 weeks.\nThe vendor is required to manage and coordinate installation at the VA NWHCC with the VA POC- Ray Reil or Jennifer Hampton.\nIf during the performance of this contract, work will be carried out on VA NWHCC/Datapoint premises, the vendor shall perform all work in such a manner that will cause a minimum interference with VA NWHCC/Datapoint operations and the operations of other contractors on the premises.\nThe vendor shall communicate through the VA POC any required coordination requirements with the General Construction contractor prior to and during delivery and installation activities.\nThe project may be an active construction site during delivery and installation. The vendor shall take all necessary precautions to protect the premises and all persons and property therein from damage or injury. The vendor shall assume responsibility for taking precautions for the vendor's (and associated subcontractors ) employees, agents, licensees, and permittees. The vendor shall abide by any safety requirements imposed by the GC (e.g. hard hats, safety vests).\nTraining Is Required\nThe vendor shall coordinate through the VA POC to provide a hands-on training session to staff selected by the VA. Training shall be completed within 45 days after final installation of equipment. The vendor will record the training and provide a electronic copy of the training to the VA POC for VA to use to train additional personal at a future date. In addition, the vendor\nshall provide additional training documents to the VA POC for training additional persons at a future date.\nClean Up and Disposal\nThere are limited used to dumpsters on site.\nThe removal of waste and/or excess material shall be conducted through the loading dock area. Delivery trucks and/or other vendor vehicles will not be permitted to remain at the loading dock. Vehicles will need to be brought back to the dock if required to remove any waste, tools, or excess materials.\nPlace of Performance\n8410 Datapoint Drive San Antonio Texas 78229 second floor Eye clinic.\n9939 State Highway 151 San Antonio Texas 78251 first floor Eye clinic.\n\nNCO 17 is seeking sources that have the capability of providing these services. Firms that can provide these services are encouraged to respond to the sources sought notice by contacting the point of contact. Capable firms must respond to the POC no later than 10AM CST on July 29, 2025, to be considered. Interested firms must identify their company name, SAM UEI number, socioeconomic category, and are asked to provide a capabilities statement with their response.\nThis notice is NOT a formal request for quote or proposals. No formal solicitation document exists currently. The information in this notice is for information and planning purposes only and is not to be construed as a commitment by the government. No contract will be awarded from this notice. The acquisition strategy will be decided based on responses and other market research efforts. If parties choose to respond, any cost associated with preparation and submission of data or cost incurred in response to this announcement shall be the sole responsibility of the contractor and will not be reimbursed by the Government.\nNotice: DO NOT respond to this notice in the Interested Vendors List. Interested firms must respond directly to Janice Malbon, Contract Specialist at: Janice.Malbon@va.gov.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25725Q0799","place_of_performance":{"zip":"78229","city":{"code":"65000","name":"San Antonio"},"state":{"code":"TX","name":"Texas"},"street":"Department Of Veterans Affairs South Texas Veterans Healthcare System","country":{"code":"USA","name":"UNITED STATES"},"street2":"7400 Merton Minter"},"product_service_code":"6540"}],"due_at":"2025-07-29T15:00:00Z","due_date":"2025-07-29","closes_at":"2025-07-29T15:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","state":"TX","county":"48029","county_name":"Bexar County","city":"4865000","city_name":"San Antonio","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-08T02:35:10.339363Z","principal_notice_id":"fa77e002e95644b495c92c11d13bd64b","description":{"text":"The Department of Veterans Affairs (VA), Veterans Health Administration, Veterans Integrated Service Network 17, Network Contracting Office (NCO) 17 is seeking sources for the following procurement:\nBrand Name or equal laser and the DPC Eye service that provides emergency laser treatment for patients that are referred from the emergency department at South Texas Veterans Healthcare System in San Antonio, Texas.\nSalient Characteristics\nOcculight visible yellow laser system 577 nm IQ 577): Provide wireless foot pedal to activate apply laser treatment to the patient.\nCustomize patterns for the treatment size.\nAdjust the Pulse duration time.\nDual External monitors to view the retina to view live images during treatment.\nAbility to import images in order map.\nSingle and multi-spot pattern delivery using standard continuous-wave or mircopulse treatment modes.\nMulti-spot pattern scanning for efficient pan retinal photocoagulation.\nStandard photocoagulation with optimized wavelengths\nAiming beam: diode laser, 635 nm nominal\nPatterns: grid (2X2 7X 7) Circle, triple arc.\nPattern spacing confluent (zero), 1-,2-,3-spot spacing in 0.25 diameter increments.\nSlit lamp style with table BQ or brand is acceptable that can withstand wear and tear by training program.\nContinuous zoom magnification.\nAdjustable eye pieces.\nFilter to protect user.\nBQ 900 Slit Lamp acceptable.\nAdapter coupled to the iridex IQ 577.\nControls thermal elevation by chopping a continuous-wave (CW) beam into an envelope of repetitive short pulses allowing the tissue to cool between pulses and reduce thermal buildup.\nFovea-friendly for retinal disorders.\nArgon laser\nLaser energy source: frequency-doubled solid state and direct diode\nMaximum power: 2000mW\nExposure duration: MicroPulse: 10-3000 ms\nExposure internal: CW-Pulse: 1.00-10.00ms\nMicropulse duration: Micropulse: 0.05-1.00ms\nMicropulse interval: 1.00-10.00 ms\nMicropulse duty cycle: preset selections of 5% , 10% , and 15 %\n(continuously adjustable from 0.4%-50%)\nAiming beam: diode laser, 635 nm nominal\nUser interface: touch-screen & Knobs\nSpot sizes: single spot: 50 um, 100um, 200um, 300 um, 500 um\nSpot sizes; multi spot: 100um, 200um, 300um, 500um\nElectrical: 100-240 VAC, 50/60 Hz\n\nStandard Warranty\nThe products shall be covered by vendor s standard warranty terms and provisions, provided, however that the warranty coverage shall be no less than the following: 5 years\nThe Vendor shall provide a warranty certificate/form stating the warranty period, terms, and information required to initiate the warranty minimal 5 years.\nThe warranty period set forth therein shall run for one year following the first day of use at NWHCC/DPC eye service.\nThe vendor shall extend such warranty directly to the customer as if such customer had purchased the Products directly from the vendor;\nThe vendor shall warrant the products against defects in material and workmanship under normal use and service, repair or replace at vendor s cost any defective Product (or issue a credit or refund, as the case may be, based on the purchase price paid, therefore.\nThe vendor shall pay (or refund the amount of) all freight and shipping charges for any defective Products returned under this paragraph.\n\nDelivery\n7400 Merton Minter San Antonio Texas 78229\n\nDelivery Schedule 0800-1600\n\nSite address (installation)\n8410 Datapoint Drive San Antonio Texas 78229 second floor Eye clinic.\n9939 State Highway 151 San Antonio Texas 78251 first floor Eye clinic.\nRequired delivery as soon as possible within 1-3 weeks.\nThe vendor is required to manage and coordinate installation at the VA NWHCC with the VA POC- Ray Reil or Jennifer Hampton.\nIf during the performance of this contract, work will be carried out on VA NWHCC/Datapoint premises, the vendor shall perform all work in such a manner that will cause a minimum interference with VA NWHCC/Datapoint operations and the operations of other contractors on the premises.\nThe vendor shall communicate through the VA POC any required coordination requirements with the General Construction contractor prior to and during delivery and installation activities.\nThe project may be an active construction site during delivery and installation. The vendor shall take all necessary precautions to protect the premises and all persons and property therein from damage or injury. The vendor shall assume responsibility for taking precautions for the vendor's (and associated subcontractors ) employees, agents, licensees, and permittees. The vendor shall abide by any safety requirements imposed by the GC (e.g. hard hats, safety vests).\nTraining Is Required\nThe vendor shall coordinate through the VA POC to provide a hands-on training session to staff selected by the VA. Training shall be completed within 45 days after final installation of equipment. The vendor will record the training and provide a electronic copy of the training to the VA POC for VA to use to train additional personal at a future date. In addition, the vendor\nshall provide additional training documents to the VA POC for training additional persons at a future date.\nClean Up and Disposal\nThere are limited used to dumpsters on site.\nThe removal of waste and/or excess material shall be conducted through the loading dock area. Delivery trucks and/or other vendor vehicles will not be permitted to remain at the loading dock. Vehicles will need to be brought back to the dock if required to remove any waste, tools, or excess materials.\nPlace of Performance\n8410 Datapoint Drive San Antonio Texas 78229 second floor Eye clinic.\n9939 State Highway 151 San Antonio Texas 78251 first floor Eye clinic.\n\nNCO 17 is seeking sources that have the capability of providing these services. Firms that can provide these services are encouraged to respond to the sources sought notice by contacting the point of contact. Capable firms must respond to the POC no later than 10AM CST on July 29, 2025, to be considered. Interested firms must identify their company name, SAM UEI number, socioeconomic category, and are asked to provide a capabilities statement with their response.\nThis notice is NOT a formal request for quote or proposals. No formal solicitation document exists currently. The information in this notice is for information and planning purposes only and is not to be construed as a commitment by the government. No contract will be awarded from this notice. The acquisition strategy will be decided based on responses and other market research efforts. If parties choose to respond, any cost associated with preparation and submission of data or cost incurred in response to this announcement shall be the sole responsibility of the contractor and will not be reimbursed by the Government.\nNotice: DO NOT respond to this notice in the Interested Vendors List. Interested firms must respond directly to Janice Malbon, Contract Specialist at: Janice.Malbon@va.gov.","html":"The Department of Veterans Affairs (VA), Veterans Health Administration, Veterans Integrated Service Network 17, Network Contracting Office (NCO) 17 is seeking sources for the following procurement:\nBrand Name or equal laser and the DPC Eye service that provides emergency laser treatment for patients that are referred from the emergency department at South Texas Veterans Healthcare System in San Antonio, Texas.\nSalient Characteristics\nOcculight visible yellow laser system 577 nm IQ 577): Provide wireless foot pedal to activate apply laser treatment to the patient.\nCustomize patterns for the treatment size. \nAdjust the Pulse duration time.\nDual External monitors to view the retina to view live images during treatment.  \nAbility to import images in order map.\nSingle and multi-spot pattern delivery using standard continuous-wave or mircopulse treatment modes. \nMulti-spot pattern scanning for efficient pan retinal photocoagulation. \nStandard photocoagulation with optimized wavelengths \n Aiming beam: diode laser, 635 nm nominal \n Patterns: grid (2X2   7X 7) Circle, triple arc. \n Pattern spacing confluent (zero), 1-,2-,3-spot spacing in 0.25 diameter increments. \nSlit lamp style with table BQ or brand is acceptable that can withstand wear and tear by training program. \nContinuous zoom magnification. \nAdjustable eye pieces. \nFilter to protect user. \nBQ 900 Slit Lamp acceptable. \nAdapter coupled to the iridex IQ 577. \nControls thermal elevation by  chopping  a continuous-wave (CW) beam into an envelope of repetitive short pulses allowing the tissue to cool between pulses and reduce thermal buildup. \nFovea-friendly for retinal disorders.\nArgon laser \nLaser energy source: frequency-doubled solid state and direct diode \nMaximum power: 2000mW \nExposure duration: MicroPulse: 10-3000 ms \nExposure internal: CW-Pulse: 1.00-10.00ms \nMicropulse duration: Micropulse: 0.05-1.00ms \nMicropulse interval: 1.00-10.00 ms \nMicropulse duty cycle: preset selections of 5% , 10% , and 15 % \n(continuously adjustable from 0.4%-50%)         \nAiming beam: diode laser, 635 nm nominal \nUser interface: touch-screen & Knobs \nSpot sizes: single spot: 50 um, 100um, 200um, 300 um, 500 um \nSpot sizes; multi spot: 100um, 200um, 300um, 500um \nElectrical: 100-240 VAC, 50/60 Hz \n\nStandard Warranty\nThe products shall be covered by vendor s standard warranty terms and provisions, provided, however that the warranty coverage shall be no less than the following: 5 years\nThe Vendor shall provide a warranty certificate/form stating the warranty period, terms, and information required to initiate the warranty minimal 5 years. \nThe warranty period set forth therein shall run for one year following the first day of use at NWHCC/DPC eye service. \nThe vendor shall extend such warranty directly to the customer as if such customer had purchased the Products directly from the vendor;\nThe vendor shall warrant the products against defects in material and workmanship under normal use and service, repair or replace at vendor s cost any defective Product (or issue a credit or refund, as the case may be, based on the purchase price paid, therefore. \nThe vendor shall pay (or refund the amount of) all freight and shipping charges for any defective Products returned under this paragraph.\n\nDelivery \n7400 Merton Minter San Antonio Texas 78229\n\nDelivery Schedule 0800-1600\n\nSite address (installation) \n8410 Datapoint Drive San Antonio Texas 78229 second floor Eye clinic. \n9939 State Highway 151 San Antonio Texas 78251 first floor Eye clinic.\nRequired delivery as soon as possible within 1-3 weeks.  \nThe vendor is required to manage and coordinate installation at the VA NWHCC with the VA POC- Ray Reil or Jennifer Hampton. \nIf during the performance of this contract, work will be carried out on VA NWHCC/Datapoint  premises, the vendor shall perform all work in such a manner that will cause a minimum interference with VA NWHCC/Datapoint operations and the operations of other contractors on the premises.\nThe vendor shall communicate through the VA POC any required coordination requirements with the General Construction contractor prior to and during delivery and installation activities.\nThe project may be an active construction site during delivery and installation. The vendor shall take all necessary precautions to protect the premises and all persons and property therein from damage or injury. The vendor shall assume responsibility for taking precautions for the vendor's (and associated subcontractors ) employees, agents, licensees, and permittees. The vendor shall abide by any safety requirements imposed by the GC (e.g. hard hats, safety vests).\nTraining Is Required\nThe vendor shall coordinate through the VA POC to provide a hands-on training session to staff selected by the VA. Training shall be completed within 45 days after final installation of equipment.  The vendor will record the training and provide a electronic copy of the training to the VA POC for VA to use to train additional personal at a future date. In addition, the vendor \nshall provide additional training documents to the VA POC for training additional persons at a future date.\nClean Up and Disposal\nThere are limited used to dumpsters on site.\nThe removal of waste and/or excess material shall be conducted through the loading dock area. Delivery trucks and/or other vendor vehicles will not be permitted to remain at the loading dock. Vehicles will need to be brought back to the dock if required to remove any waste, tools, or excess materials.\nPlace of Performance\n8410 Datapoint Drive San Antonio Texas 78229 second floor Eye clinic. \n9939 State Highway 151 San Antonio Texas 78251 first floor Eye clinic.\n\nNCO 17 is seeking sources that have the capability of providing these services. Firms that can provide these services are encouraged to respond to the sources sought notice by contacting the point of contact. Capable firms must respond to the POC no later than 10AM CST on July 29, 2025, to be considered.  Interested firms must identify their company name, SAM UEI number, socioeconomic category, and are asked to provide a capabilities statement with their response. \nThis notice is NOT a formal request for quote or proposals.  No formal solicitation document exists currently.  The information in this notice is for information and planning purposes only and is not to be construed as a commitment by the government.  No contract will be awarded from this notice. The acquisition strategy will be decided based on responses and other market research efforts. If parties choose to respond, any cost associated with preparation and submission of data or cost incurred in response to this announcement shall be the sole responsibility of the contractor and will not be reimbursed by the Government.\nNotice: DO NOT respond to this notice in the Interested Vendors List. Interested firms must respond directly to Janice Malbon, Contract Specialist at: Janice.Malbon@va.gov.","origin":"detail"},"contacts":[{"name":"Janice Malbon","role":"primary","email":"janice.malbon@va.gov","phone":"(210) 694-6340","title":"Contract Specialist"}],"place_of_performance":{"zip":"78229","city":{"code":"65000","name":"San Antonio"},"state":{"code":"TX","name":"Texas"},"street":"Department Of Veterans Affairs South Texas Veterans Healthcare System","country":{"code":"USA","name":"UNITED STATES"},"street2":"7400 Merton Minter"},"office_address":{"zip":"78240","city":"San Antonio","state":"TX","country":"USA"},"naics_codes":["334510"],"award":{"awardee":{}},"attachments":[{"resource_id":"ba5571e8cfaf4642814cc1f4b477b055","name":"36C25725Q0799.docx","kind":"file","mime_type":".docx","size_bytes":29955,"posted_at":"2025-07-25T16:29:22.559Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/ba5571e8cfaf4642814cc1f4b477b055/download","mirrored":false}],"awards":[],"related":[{"key":"36C25727R0012","latest_notice_id":"1e9cdf40734c4926bc09cfc12390022b","title":"V225--Amarillo and Big Springs Air Ambulance","solicitation_number":"36C25727R0012","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"621910","psc":"V225","set_aside":"SDVOSBC","state":"TX","county":"48375","county_name":"Potter County","city":"4803000","city_name":"Amarillo","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C25727Q0027","latest_notice_id":"0d1de2b7c20d45b99cb735b3d4beccd3","title":"WTX Elevator Inspections and Load Testing Services - Amended","solicitation_number":"36C25727Q0027","notice_type":"k","first_type":"k","first_posted":"2026-10-19","last_posted":"2026-11-20","notices":4,"due_at":"2026-11-30T19:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"238290","psc":"J039","set_aside":"SDVOSBC","state":"TX","county":"48227","county_name":"Howard County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C25727Q0104","latest_notice_id":"9c3ddb4326164d4fa71ad956d4194f7c","title":"6515--36C257-27-AP-0953 Prosthetic STX 671 O2 Equipment (VA-27-00016458)","solicitation_number":"36C25727Q0104","notice_type":"o","first_type":"p","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":3,"due_at":"2026-11-30T19:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"339113","psc":"6515","set_aside":"SDVOSBC","state":"TX","county":"48029","county_name":"Bexar County","city":"4865000","city_name":"San Antonio","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C25727Q00310002","latest_notice_id":"c463c6aa97b7496d99268a3c961117de","title":"NTX Elevator Inspection - Amendment","solicitation_number":"36C25727Q0031-0002","notice_type":"k","first_type":"k","first_posted":"2026-11-04","last_posted":"2026-11-04","notices":1,"due_at":"2026-11-30T21:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"541350","psc":"J036","set_aside":"SDVOSBC","state":"TX","county":"48113","county_name":"Dallas County","city":"4819000","city_name":"Dallas","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-05T04:36:35.392694Z"},{"key":"36C25727Q0052","latest_notice_id":"366f45568a854b0cad0c51cb35650156","title":"Sit-to-Stand Lift","solicitation_number":"36C25727Q0052","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"339112","psc":"6515","set_aside":null,"state":"TX","county":null,"county_name":null,"city":"4819000","city_name":"Dallas","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"REQTIHS202600220","latest_notice_id":"ef16a1513b85491d928fcb190b3fe772","title":"Vital Signs Monitoring and Physical Assessment Units","solicitation_number":"REQT-IHS-2026-00220","notice_type":"r","first_type":"r","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":"2026-11-26T01:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-26T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7527","sub_name":"INDIAN HEALTH SERVICE","office_key":"o-75H713","office_name":"INDIAN HEALTH SERVICE","naics":"334510","psc":"6515","set_aside":null,"state":"OR","county":"41047","county_name":"Marion County","city":"4164900","city_name":"Salem","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"75N98027Q00094","latest_notice_id":"fe80b99f89894110b18ddb4d826a2131","title":"NCSS - Sentec tCOM+ Transcutaneous CO2 Monitor Acq","solicitation_number":"75N98027Q00094","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T16:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334510","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C26327Q0131","latest_notice_id":"885e687dd48e45c295666a91fc27da2b","title":"6515--Medtronic FT10 Series Cauterizer","solicitation_number":"36C26327Q0131","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-30T16:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C263","office_name":"NETWORK CONTRACT OFFICE 23 (36C263)","naics":"334510","psc":"6515","set_aside":"SDVOSBC","state":"ND","county":"38017","county_name":"Cass County","city":"3825700","city_name":"Fargo","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T07:05:05.540398Z"}],"similar_open_total":12,"indexable":false}