# Mobile Magnetic Resonance Imaging System (MRI) and MRI Technologist Lease

Canonical: https://sealedbidder.com/opportunities/36c25725ap1637

- Solicitation number: 36C257-25-AP-1637
- Notice type: Sources sought
- Status: Closed. Deadline was March 28, 2025 at 12:00 PM EDT
- Department: Department of Veterans Affairs
- Contracting office: 257-Network Contract Office 17 (36C257)
- NAICS: 532490 Other Commercial and Industrial Machinery and Equipment Rental and Leasing
- Product or service code: W065 Lease or Rental of Equipment: Medical, Dental, and Veterinary Equipment and Supplies
- Small business size standard: $40 million in average annual receipts (13 CFR 121.201, NAICS 532490)
- Place of performance: Big Spring, Texas
- County: Howard County (FIPS 48227). https://sealedbidder.com/counties/howard-county-tx-48227
- City: Big Spring. https://sealedbidder.com/cities/big-spring-tx-4808236
- First posted: March 24, 2025
- Last posted: March 24, 2025
- SAM.gov: https://sam.gov/workspace/contract/opp/e34252bed1164b9c8e6b414a6e82da69/view

## Reading this notice

- Kind of notice: Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it.
- Who may compete: SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 532490 (other commercial and industrial machinery and equipment rental and leasing), means no more than $40 million in average annual receipts, counted with affiliates.
- What comes next: No solicitation was published under this number after the sources sought of March 24, 2025. An agency sometimes issues the solicitation under a new number.

## Description

Scope: The intent of this Request for Proposal is to enter into a contract to provide Mobile MRI and Technologist Services to include all the necessary personnel, supervision, equipment, transportation, materials, supplies and training to perform the services as specified herein. Service shall be performed at any West Texas VA Healthcare Facility, including both owned and/or leased facilities, main and/or community-based outpatient clinics where indicated.

	Summary of Requirement: The West Texas Healthcare System is seeking a 12-month Base, plus 4 (four) 12-month Option Periods, contract for a mobile MRI and associated service agreement and Technologist staffing. The mobile MRI will be placed on an as-needed basis for delivery or move within 10 days, to remain in a single location no less than 6 months.

	Delivery and Set-up of Contractor Equipment:  The Contractor shall be responsible for proper installation/set-up of the Contractor's furnished equipment including the mobile coach. Installation/set-up shall be accomplished in accordance with industry standards, all OSHA regulations and applicable manufacturer's recommendations.

		The Contractor shall provide a mobile 1.5T MRI coach and MRI Technologists Services at station 519 (West Texas Healthcare System), in accordance with the SOW (Statement of Work).

		Schedule:  Services shall be required five (5) days per week, except on federal holidays.

		Hours of Service:  Contractor's mobile unit and/or personnel shall be on site to perform exams eight (8) hours per day, Monday - Friday, between the hours of 7:30 am and 4:30 pm. The first MRI will begin at 7:30 am with the last patient being seen such that the exam is completed no later than 4:30pm.

		Pro-rated Monthly Rental Fee: The Contractor shall prorate the monthly rental fee when MRI coach is not functioning in accordance with prescribed guidelines.  The monthly fee shall be prorated based on the number of hours the coach is out of service during regularly scheduled clinic hours M-F, 7:30am &ndash; 4:30pm.  The Contractor shall include the hourly rate in the space provided below:

	Contractor's Responsibilities:  The Contractor shall be responsible for the following daily functions:

		Contractor shall be responsible for the transportation of the Mobile MRI coach to and from WTVAHCS. Cost of transportation shall be included in the monthly rate. Big Spring facility is gated and locked after-hours. The facility is open from 6:30 am through 6 pm Monday through Friday for removal of trailer for other assignments.

		Delivery and Set-up of Contractor Equipment: The Contractor shall be responsible for proper installation/set-up of the Contractor's furnished equipment including the mobile trailer. Installation/setup shall be accomplished in accordance with industry standards, all OSHA regulations and applicable manufacturer's recommendations.

		Transmit completed electronic data after each exam.  Ensure that all of the day&rsquo;s exam data is completely transferred to the West Texas VA Healthcare System computer systems.

		All patient information required for Contractor's records shall be secured in accordance with HIPAA guidelines.

		All connections from the trailer to West Texas VA Healthcare System site/property are properly disconnected from trailer when moved from the site.

		Any temporary site preparations are removed upon completion of services.

		Contractor shall ensure mobile MRI is maintained in optimum working condition to ensure the highest level of patient safety at all times. Fire extinguisher to be supplied by the vendor. Vendor shall provide MRI compatible wheelchair, stretcher and O2 tank.

		Maintenance documents shall be made available to the West Texas VA Healthcare System upon request.

		Contractor shall ensure each patient arriving for mobile MRI exam has a signed MRI order for services.

		MRI tech must complete the final MRI Screening Assessment which is incorporated in the patient&rsquo;s electronic medical record.

		Contractor shall use appropriate screening devices to ensure patient has no ferro-magnetic materials on or in receive his/her body.

		Contractor shall be responsible for adhering to all Federal regulations regarding patient care, patient safety, medical practice and operation of mobile MRI.

		Contractor shall provide a copy of a current, comprehensive MRI Safety Program policy to which each technologist is expected to comply. MRI Technologist is required to complete West Texas VA Healthcare System or analogous MRI Safety Training yearly.

		Contractor shall be responsible for patient while on the mobile unit and during the entire scanning procedure up to the patient's release.

		In the event a patient is injured while in Contractor's care, Contractor shall immediately notify the assigned nurse or a designated VA physician and complete a written report.

		Environment of Care Rounds shall be conducted quarterly by the local site COR and West Texas VA Healthcare System Administrator. All identified deficiencies shall be corrected by the Contractor prior to the next scheduled day of service.

		Contractor shall be responsible for providing 2 qualified MRI Technologists to perform services defined herein. The MRI Technologists shall be required to provide scanning services as well as training on the full operation of the Mobile MRI unit. Training shall be provided to the assigned West Texas VA Healthcare System technical personnel at no additional cost to the Government. If the MRI Technologist is unable to come in to work as per the schedule, an alternate MRI Technologist is available to cover the shift to avoid having to reschedule patients. All MRI Technologists must complete the credentialing requirements established by West Texas VA Healthcare System.

		MRI Technologist shall attend the quarterly MRI Safety Committee meeting.

		Comply with VHA Directive 1105.05 Magnetic Resonance (MR) Safety, WTVAHCS MRI Policy and Procedures and MRI scanning protocols.

5. Delivery Locations:

            See below for location of West Texas VA Healthcare System sites of care. The delivery locations include but are not limited to these locations. If new VA locations within the geographic boundaries of West Texas VA Healthcare System (such as a new clinic in Abilene) are added during the duration of the contract, those will presume to be included as potential deployment locations for a mobile MRI as well, provided that they are affiliated with station 519.

George H. O'Brien, Jr., Department of Veterans Affairs Medical Center

300 Veterans Boulevard

Big Spring, TX 79720-5566

Abilene VA Clinic

3850 Ridgemont Drive

Abilene, TX 79606-2728

Colonel Charles and JoAnne Powell VA Clinic

4240 Southwest Boulevard

San Angelo, TX 76904-5634

Fort Stockton VA Clinic

1205 North Sycamore Street

Fort Stockton, TX 79735-4122

Hobbs VA Clinic

1301 North Turner Street

Hobbs, NM 88240-8446

Wilson and Young Medal of Honor VA Clinic

8050 East Highway 191

Odessa, TX 79765-8615

8. Magnetic Resonance Imaging (MRI) Mobile Device Salient Characteristics:

Contractor shall make whatever adaptations are necessary so that the Contractor's equipment is compatible with the West Texas Healthcare System data network as specified in Paragraph 16, Telecommunications.

Salient characteristics

Details

Magnet strength

1.5 Tesla

Minimum Bore width (cm)

70cm

Minimum bore depth (cm)

130cm

Minimum slew rate (T/m/s)

125

Minimum number of channels

48

Maximum patient table load capacity for vertical and horizontal table movement (lbs)

550

Maximum system weigh (lbs)

10,000

Helium consumption

Zero Helium boil-off technology

Min patient comfort requirement

Short and wide bore for greater patient comfort and easier access for various patient sixes

Gradient system

XJ Gradients with high performance capable of handling advanced imaging techniques

RF Technology

TIM 4G 9Toal Imaging Matrix) technology, allowing flexible coil combinations and faster imaging

Coil Technology

Up to 204 coil elements, allowing for whole body imaging without patient repositioning

Imaging speed

Up to 48 channels supported with Tim 4G, enabling faster scans and higher throughput

Image quality

High spatial and temporal resolution, with advanced features, post processing and workflow optimization tools

Patient handling

Comfortable positioning for long exams, with respiratory and cardiac gating options

Application range

Neurology, musculoskeletal, cardiovascular, Ortho, Oncology, MRA, Elastography, Spectroscopy, Phase contrast MRI and flow analysis, parametric prostate imaging, high intensity focused ultrasound with the flexibility to expand due to different facility provider requirements

Advanced Imaging Techniques

Diffusion weighted imaging (DWI), functional MRI (fMRI), cardiac imaging, MR spectroscopy, etc.

Environment

Energy efficiency and reduced operating costs

Installation space

Mobile trailer installation capable; Semi-trailer truck equipped with stabilizing shocks to prevent disruption of the machine, compact design with low space requirements ideal for a mobile trailer

Operator workflow

Intuitive user interface, customizable protocols, and easy data management

Connectivity

DICOM compliant integrated with hospital information system (HIS) and Picture Archiving (PACS)

Upgradeable

Must be upgradeable to newer software and hardware innovations

Safety features

Advanced patient monitoring, acoustic noise reduction, and patient emergency systems. Safety system for magnet quenching and emergency shutdown, to include the following:

	Alarms for low cryogen levels, temperature limits, scans in progress

	Indicators for cryogen levels

	 Heat sensor shut offs for room temperature problems.

	Oxygen monitor in gantry room.

Table requirement

	Motorized

	Detachable

	Adjustable height

	Stepping capable

UPS requirement

Maintains full functionality of the system for a minimum of 30 minutes during a power outage

Coil requirement

Imaging of the Torso, knee, shoulder, head/spine/array, neuro vascular, run-off, foot/ankle, wrist, elbow, cardiac, breast, prostate imaging, functional MRI head, carotid, endorectal, periphery vascular, extremity, flexible, transmit/receive, adjustable neurovascular head, whole body imaging

Security/Connectivity requirements

	OEM supported operating system.

	Latest DICOM print, store, commit, structured report (SR) and modality worklist.

	Wireless connectivity to VA network &ndash; Compatible with 802.11b/g/n and FIPS 140-2 or FIPS 140-3 compliant

	Encrypted hard drive.

	PACS compatibility &ndash; Change Healthcare

	Integration to Advanced Visualization Systems

Chiller requirement

Chiller meeting or exceeding MRI needs

Cryogen requirement

Cryogens (Vendor expected to provide and install all cryogens.)

Phantom requirements

All phantoms required for proper calibration and performance verification (Vendors are expected to provide phantoms for all system requirements and options identified in this document that require phantoms.)

Patient comfort/entertainment package

Integrated music system, to include the following:

	Control room controls

	Speech communication for patient direction

	Speakers in both the exam room and control room

	Headphone jack on patient table

	MRI-safe headphones

Shielding requirement

Active Shielding

Workstation requirement

	Min acquisition workstation monitor size of 19in

	Minimum acquisition workstation hard drive space 200 [GB]

	Minimum number of processing/reading workstations: 2

	Minimum processing/reading workstation monitor size 19 [in]

	Minimum processing/reading workstation hard drive space 200 [GB]

Additional technology specifications

	Compressed sense technology

	Motion correction technology

	Helium save technology.

	Noise reduction technology

	Power conditioning

	Vector ECG(VCG), respiratory and peripheral pulse gating/triggering

	Advanced Exam planning technology

	Geometry linking (multi station exams)

	Real time MIP, MPR, AND 3D surface rendering

	Advanced MR viewing environment, processing, and image generation.

	Patient specific shimming

	Dixon type technology for body, neuro, and musculoskeletal imaging

	Advanced non-contrast MRA imaging technology

	3D FSE based sequence for isotropic resolution in all contrasts.

	Bolus tracking system

	Heavy duty wide patient restraints

	Patient positioning and support aids

	Video camera system for monitoring inside the exam room from the control room

	MRI-compatible contrast injector

	Operating system must be Windows 10 or newer

	The scanner must be able to scan the cervical, thoracic, and lumbar spines continuously without requiring patient movement.

	The Mobile MRI unit shall be ready for use regardless of outside environmental conditions.

	The Mobile MRI unit shall maintain a temperature to assure proper operation of the scanner and provide for patient comfort.

	The Mobile MRI unit shall include a private dressing area with secured cabinets for patient use.

	Contractor shall provide an MRI-compatible Automatic External Defibrillator (AED).  The system must contain the minimum characteristics:

		AED Unit with LCS Screen showing voice prompt messages, device advisory messages, elapsed time, shock count and chest compression graph, Operator's Guide and Carrying Case;

		Two (2) Sets of CPR-D Pads, one piece defibrillation and CPR system with compression, depth and rate sensors, supplies with gloves, barrier mask, scissors, razor, wet wipes and dry wipes.

Trailer space requirement

(based on max system dimensions)

Location

Requirement

Width (cm)

Depth (cm)

Height (cm)

Weight (cm)

Examination Room

Magnet and Helium

210

150

220

3200

Magnet, gradient coils body coil, table and covers

250

450

225

5000

Min room height clearance

245

Control Room

Workplace table and monitor

130

90

120

Equipment room

Cabinets with system controls, RF system, gradient power system image processor

170

70

200

1500

9. MRI Technologist Staffing Salient Characteristics:

a.    The Contractor's Technologists shall possess a current American Registry of Radiologic Technologists (ARRT) license, certified in MRI through ARRT and Basic Life Support (BLS) certified.  A copy of all applicable operators&rsquo; license/certifications shall be provided with the proposal along with a copy of the updated license immediately upon renewal.  The Contractor shall ensure that a copy of the technologist&rsquo;s current license is provided to the local COR for inclusion in the West Texas VA Healthcare System 6-part folder at all times.

b.   The Contractor shall be responsible to ensure that Contractor employees providing work on this contract are fully trained and completely competent to perform the required work.  Evidence of the Contractor&rsquo;s Technologist&rsquo;s competency review shall be provided with the proposal.  Competency checklists must contain evidence of supervisory review at least annually and must contain the written signature of the supervisory official performing the review.  A current copy of the employee&rsquo;s competency checklist shall be maintained in West Texas VA Healthcare System 6-part folder at all times.  Competency checklists shall be resubmitted to West Texas VA Healthcare System each time the checklist is updated, no more than 12 months beyond the original date of review.

c.   The Contractor shall be required to maintain documentation and provide copies, with their proposal, of the following for each employee working under the contract:

(1)  credentials and qualifications for the job

(2)  a current competency assessment checklist (an assessment of knowledge, skills, abilities and behaviors required to perform a job correctly and skillfully; includes age-specific knowledge and skills required to provide care for certain patient populations, as appropriate.)

(3)  a listing of relevant continuing education for the last two years.

(4)  health examination records of all individuals performing work under this contract to include:

(a)  Annual TB Skin Test and recent (within the last year) chest X-ray if there is a history of positive TB skin test

	Evidence of Hepatitis B immunity (hepatitis immune titer, if provider has had the series of shots; if no immunity, evidence that provider has started the Hepatitis B vaccination series.)

	Varicella titer if provider has not had chicken pox and has direct patient contact.

d.    This is a non-personal health care service contract under which the Contractor is an independent Contractor.  Contractor employees shall not be considered VA employees for any purpose.

10.  HOUSEKEEPING REQIREMENTS: The contractor is responsible for all housekeeping requirements. Environment of Care Rounds shall be conducted and deficiencies shall be corrected by the Contractor prior to the next scheduled day of service.

11. MAINTENANCE REQUIREMENTS:

a.   Contractor shall be responsible for all maintenance of the unit including all Preventive Maintenances (PMs) as required by the manufacturer&rsquo;s literature. The Contractor shall assume all cost for labor and parts including glassware and will make all arrangements for service upon notification of failure. Contractor shall communicate these occurrences and progress in a timely manner with Imaging Service staff and Healthcare Technology Management Staff. Anyone performing maintenance on the unit shall be factory trained by the manufacturer on this specific unit.  Any FDA alerts or recalls associated with this equipment will be ameliorated in a timely manner.

b.   All PMs shall be done after normal operating hours, Monday &ndash; Friday.

c.   Contractor shall ensure a 98% or better up-time based upon the normal operation hours, Monday &ndash; Friday, 7:30 a.m. &ndash; 4:30 p.m.

d.  If the system breaks down, the MRI Technologist is responsible for informing Imaging Service representative and Healthcare Technology Management of the issue immediately upon determining there is a problem. The MRI Technologist will contact the vendor immediately if an on-site service technician is needed. It is expected that the on-site service technician will respond within 2 hours to determine what the problem is and a proposed timeframe of how long the machine is expected to be down. Repairs and delays that will be beyond two working days will require a replacement trailer to be brought in.

12. THE WEST TEXAS HEALTHCARE SYSTEM RESPONSIBILITIES:

a.   The West Texas VA Healthcare System shall provide a covered walkway (per VA design guidelines where applicable), utility connections, and an appropriate computer line(s) for use by the Contractor.

	The West Texas VA Healthcare System shall be responsible for scheduling exams for the mobile MRI unit.

	Providing Mobile MRI Pad:

	Mobile Pad (MRI criteria most stringent)

		Size: 55&rsquo; X 11&rsquo;

		12&rdquo; thick, no steel reinforcing under scanner section (may use carbon fiber, polyester, stainless steel)

		Assess for vibration (road, adjacent machinery)

		Assess for RF interference (adjacent electrical equipment, etc.)

	Connectivity:

		480V 3 phase power, Russell Stoll connector

		Data , telephone, water

13.       CONFORMANCE STANDARDS/REGULATORY ADHERENCE:

a. Contractor shall perform the required services in accordance with the following:

      (1)  the standards of the Joint Commission for the Accreditation of Healthcare Organizations (JC) to include Patient Safety Standards (a copy of these standards may be obtained from the Joint Commission on Accreditation of Healthcare Organizations, One Renaissance Blvd., Oakbrook Terrace, IL 60181)

      (2)  the established principles and ethics of the medical profession established by the AMA and ACEP and is responsible for the quality of care rendered to all patients.

(3) all relevant Federal and State regulations regarding patient care, medical practice, operation of MRI equipment; to include but not be limited to:

Occupational Safety and Health Act (OSHA)

The Joint Commission (JC)

Veterans Health Administration (VHA)

United States Department of Transportation (US DOT)

Health Information Portability and Accountability Act (HIPAA)

VHA Automated Information Security (AIS)

Privacy Act

THE VISN 17 FACILITY Medical Staff Bylaws

b.   Contractor shall ensure that the equipment/system functions in conformance with the latest published edition of OSHA and the manufacturer's specifications.

c.   Contractor shall adhere to the provisions of Public Law 104-191, Health Insurance

Portability and Accountability Act (HIPAA) of 1996 and the National Standards to Protect the

Privacy and Security of Protected Health Information (PHI).  As required by HIPAA, the

Department of Health and Human Services (HHS) has promulgated rules governing the

security and use and disclosure of protected health information by covered entities, including the Department of Veterans Affairs Veterans Health Administration (VA).

14. MRI STUDY INTERPRETATION:  A VA-identified radiologist shall read/interpret all MRI studies and dictate all required study reports.

		MRI DATA OWNERSHIP: The West Texas Healthcare System shall maintain sole ownership of all data of studies performed on the mobile MRI under this contract.  The Contractor may not use any portion of imaging data obtained from patient studies under the contract.  The Contractor may not use any portion of imaging data obtained from patient studies for quality control or educational purposes without written consent of the West Texas Healthcare System.

15. EMERGENCIES ON MOBILE MRI UNIT:  Emergency 911 shall handle all medical emergencies occurring on the mobile coach. The Contractor shall provide, with their proposal, a written emergency plan addressing emergencies such as patient codes, personal injury, fire, and disruptive behavior.

16. TELECOMMUNICATIONS:

a.   The mobile unit shall be equipped with an outlet connection capable of transmitting data and voice through a Government provided network interface jack (RJ11 Analog Voice and RJ45 IEEE 803.x). The Government shall provide the necessary network services required for the transmission of images, data and voice. The Contractor's mobile unit shall be able to connect to VISTA Imaging Network and to transmit all images to VISTA Imaging to include being compatible to DICOM imaging standards in use at the West Texas Healthcare System. (PACS interface contact person shall be provided to the Contractor during the post-award orientation).

b.   The Contractor shall be responsible for all expenses incurred to interface the MRI  Scanner OEM using the DICOM network with the existing in use West Texas Healthcare System  Picture Archiving and Communications System.

	The intent of this notice is to establish sources to define the procurement strategy (e.g., set- aside, sole source, unrestricted) for a solicitation that VA intends to post soon. Interested Contractors are requested to respond in accordance with the following:

		If you have an existing GSA or VA, Federal Supply Schedule contract, include the contract details in your response.

		Please note that VA is particularly interested in determining the availability of Small Business that can provide this service.

		Vendors are requested to submit estimated market research pricing with their responses. The estimated pricing will be considered when determining the procurement strategy for the future solicitation. (e.g., if the CO determines that capable small businesses cannot provide fair and reasonable pricing, then the solicitation will not be set-aside).

	Responses shall include:

	Business Name

	Business Address

	Point of Contact

		Name

		Phone Number

		E-mail Address

	SAM UID Number

	Currently registered in SAM (Yes or No). If Yes, provide expiration date.

	NAICS code

	Business Size: Small or Large

	Type of Business: Service-Disabled Veteran Owned (SDVOSB), Veteran Owned (VOSB), 8(a), HUBZone, Woman-Owned (WOSB), etc.

	GSA or VA FSS Contract Number, if applicable

	Current fleet size

	The contractor shall provide Emergent, non-emergent Advanced Life Support (ALS), and Critical Care Transport (CCT) Tier 1, 2, and 3 ambulance services on an

as-needed basis in accordance with all federal, state, and local regulations.

All businesses eligible to provide this service are encouraged to reply as this information may be used to determine potential set-asides for the above-noted requirement.

	Send responses to both the Contract Specialist and the Contracting Officer.

Contracting Officer: Mr. Rafael Rodriguez at  Rafael.Rodriguez2@va.gov

## Attachments

- [Description Sources Sought.docx](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/ef50c4011b6e443892f8de9f50d32799/download)

## Open now in the same industry

19 open in NAICS 532490.

- Mobile CT Scanner and technicians for Veterans Affairs Longview TX (36C25627Q0112), due November 27, 2026 at 6:00 PM EST. https://sealedbidder.com/opportunities/36c25627q0112
- RFQ | SBAR APPROVED | BED RENTAL WD WD EXEMPT (36C26227Q0079), due November 26, 2026 at 3:00 PM EST. https://sealedbidder.com/opportunities/36c26227q0079
- CGC FLORENCE FINCH Telescopic Handler Rental (52000QR270001331), due November 27, 2026 at 2:30 PM EST. https://sealedbidder.com/opportunities/52000qr270001331

## Publications

- March 24, 2025: Sources sought, due March 28, 2025 at 12:00 PM EDT. Notice e34252bed1164b9c8e6b414a6e82da69. https://sam.gov/workspace/contract/opp/e34252bed1164b9c8e6b414a6e82da69/view

## Points of contact

- Rafael Rodriguez, Rafael.Rodriguez2@va.gov, (254) 560-0262

---
Source: SAM.gov Contract Opportunities bulk extract. Confirm deadlines on SAM.gov before responding. Cite https://sealedbidder.com/opportunities/36c25725ap1637.