{"canonical":"https://sealedbidder.com/opportunities/36c25626q0321","key":"36C25626Q0321","url":"https://sealedbidder.com/opportunities/36c25626q0321","title":"H936--Annual Elevator Inspections","solicitation_number":"36C25626Q0321","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-02-10T16:00:00Z","first_posted":"2026-01-22","last_posted":"2026-01-22","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"256-NETWORK CONTRACT OFFICE 16 (36C256)","naics":"238290","psc":"H936","set_aside":null,"place_state":"AR","place_scope":"site","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"05119","place_county_name":"Pulaski County","place_city":"0541000","place_city_name":"Little Rock","winner":null,"award_amount":null,"publications":[{"notice_id":"81eda2f0cd45485aad1462d0a1597efd","title":"H936--Annual Elevator Inspections","solicitation_number":"36C25626Q0321","notice_type":"r","base_type":"r","posted":"2026-01-22","posted_at":"2026-01-22T14:00:40.047Z","due_at":"2026-02-10T16:00:00Z","due_date":"2026-02-10","cancelled":false,"archived":true,"archive_date":"2026-03-12","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/81eda2f0cd45485aad1462d0a1597efd/view","enriched":true,"history":[{"index":3,"title":"H936--Annual Elevator Inspections","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-22T14:00:40.047Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"81eda2f0cd45485aad1462d0a1597efd","solicitation_number":"36C25626Q0321"}]}],"latest_notice_id":"81eda2f0cd45485aad1462d0a1597efd","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-01-22","posted_at":"2026-01-22T14:00:40.047Z","created_at":"2026-01-22T14:00:37.846Z","modified_at":"2026-03-13T04:04:29.084Z","response_deadline":{"raw":"2026-02-10T10:00:00-06:00","utc":"2026-02-10T16:00:00Z","date":"2026-02-10","time":"10:00:00","timezone":"America/Chicago","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/81eda2f0cd45485aad1462d0a1597efd/view"},"naics":{"codes":["238290"],"primary":"238290"},"title":"H936--Annual Elevator Inspections","agency":{"office":{"code":"36C256","name":"256-NETWORK CONTRACT OFFICE 16 (36C256)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"39157","city":"RIDGELAND","state":"MS","country":"USA"},"organization_id":"100186525","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-03-12","archive_type":"auto_custom"},"history":[{"index":3,"title":"H936--Annual Elevator Inspections","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-22T14:00:40.047Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"81eda2f0cd45485aad1462d0a1597efd","solicitation_number":"36C25626Q0321"}],"contacts":[{"name":"Carmyn E Williams","role":"primary","email":"Carmyn.Williams@va.gov","phone":"713-799-0795","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"81eda2f0cd45485aad1462d0a1597efd","lineage_id":"81eda2f0cd45485aad1462d0a1597efd","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-15T02:07:43.391544693Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"970fb756b6f774707892e4ef0b07023010998ed7d138f07f68e2a1c0765df102","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-15T02:07:43.391544693Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"Sources Sought Notice (SSN)\n\nDepartment of Veterans Affairs, Veterans Health Administration, Network Contracting Office 16\n(NCO16)\n\nThis SSN is for market research and planning purposes only and shall not be considered an\nInvitation for Bid (IFB), Request for Task Execution Plan, Request for Quotation (RFQ), or a\nRequest for Proposal (RFP). Additionally, there is no obligation on the part of the Government to\nacquire any products or services described in this SSN. Your response to this SSN will be treated\nonly as information for the Government to consider. You will not be entitled to payment for\ndirect or indirect costs that you incur in responding to this SSN. This request does not constitute\na solicitation for proposals or the authority to enter negotiations to award a contract. No funds\nhave been authorized, appropriated, or received for this effort. Interested parties are responsible for adequately marking proprietary, restricted, or competition-sensitive information contained in their response. The Government does not intend to pay for the information submitted in response to this SSN.\n\nThe North American Industry Classification System (NAICS) for this requirement is 238290\nwith a size standard of $22.0 Million and Product Service Code (PSC) of H330.\n\nPlease note that this is a draft Statement of Work.\n\nDRAFT STATEMENT OF WORK (SOW)\nElevator Inspection\nElevator safety inspections for all traction and hydraulic elevators located at Central Arkansas Veterans Healthcare System (CAVHS) in Little Rock and North Little Rock, AR.  The elevator maintenance contractor under contract with the CAVHS at the specific building location will be present and assist in the inspection and testing. The elevator maintenance contractor will provide the necessary expertise, manpower, test weights, gauges, dynamometers, etc., to perform the various inspections and tests required by code. The elevator inspector shall provide door pressure gauges, stopwatches, calipers, flashlights, and other small hand tools necessary to conduct inspections.\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n4300 West 7th Street, Little Rock, AR\nPassenger Cab Elevators\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n1\nP-1\n1\n4,000\n1984\n500\n8\nPower Doors\n2\nP-2\n1\n4,000\n1984\n500\n8\nPower Doors\n3\nP-3\n1\n4,000\n1984\n500\n8\nPower Doors\n4\nP-4\n1\n4,000\n1984\n500\n8\nPower Doors\n5\nP-5\n1\n4,000\n1984\n500\n8\nPower Doors\n6\nS-1\n1\n5,000\n1984\n500\n8\nPower Doors\n7\nS-2\n1\n5,000\n1984\n500\n8\nPower Doors\n8\nS-3\n1\n5,000\n1984\n500\n8\nPower Doors\n9\nS-4\n1\n5,000\n1984\n500\n8\nPower Doors\n10\nS-5\n1\n5,000\n1984\n500\n8\nPower Doors\n17\nVA-UAMS\n1\n4,500\n1984\n150\n1\nPower Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n4300 West 7th Street, Little Rock, AR\nCart Lift\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n11\nCartlift-1\n1\n300\n1984\n300\n8\nManual Doors\n12\nCartlift-2\n1\n300\n1984\n200\n8\nManual Doors\n13\nCartlift-3\n1\n300\n1984\n300\n8\nManual Doors\n14\nCartlift-4\n1\n300\n1984\n200\n8\nManual Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n4300 West 7th Street, Little Rock, AR\nDumbwaiter\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n15\nDW-1\n1\n300\n1984\n200\n8\nManual Doors\n16\nDW-2\n1\n300\n1984\n200\n8\nManual Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n4300 West 7th Street, Little Rock, AR\nPassenger Hydraulic Elevator\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n18\nMICU/1F\n1\n5,000\n2003\n100\n1\nPower Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n2200 Fort Roots Drive, North Little Rock, AR\nPassenger Cab Elevators\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n1\nBldg 58\n1\n3,500\n1965\n200\n3\nPower Doors\n2\nBldg 65\n1\n3,500\n1990\n200\n3\nPower Doors\n4\nBldg 66\n1\n3,500\n1968\n200\n3\nPower Doors\n6\nBldg 68\n1\n3,500\nUnknown\n200\n3\nPower Doors\n9\nBldg 111\n1\n3,500\n1966\n100\n3\nPower Doors\n11\nBldg 170\n1\n3,500\n1982\n350\n4\nPower Doors\n12\nBldg 170\n1\n4,000\n1982\n350\n4\nPower Doors\n13\nBldg 170\n1\n4,000\n1982\n350\n4\nPower Doors\n14\nBldg 170\n1\n4,000\n1982\n350\n4\nPower Doors\n15\nBldg 170\n1\n4,000\n1982\n350\n4\nPower Doors\n16\nBldg 170\n1\n5,000\n1982\n350\n4\nPower Doors\n17\nBldg 170\n1\n5,000\n1982\n350\n4\nPower Doors\n18\nBldg 170\n1\n5,000\n1982\n350\n4\nPower Doors\n19\nBldg 170\n1\n5,000\n1982\n350\n4\nPower Doors\n20\nBldg 170\n1\n5,000\n1982\n100\n4\nPower Doors\n21\nBldg 170\n1\n5,000\n1982\n350\n4\nPower Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n2200 Fort Roots Drive, North Little Rock, AR\nPassenger Hydraulic Elevators\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n3\nBldg 65\n1\n4,000\nUnknown\n150\n3\nPower Doors\n5\nBldg 66\n1\n4,000\nUnknown\n125\n3\nPower Doors\n8\nBldg 103\n1\n2,500\n1989\n125\n3\nPower Doors\n22\nBldg 170\n1\n5,000\n1982\n350\n4\nPower Doors\n24\nBldg 190\n1\n2,500\n1994\n125\n3\nPower Doors\n25\nBldg 190\n1\n2,500\n2011\n100\n3\nPower Doors\n27\nBldg 89\n1\n2,000\n2002\n100\n2\nPower Doors\n28\nBldg 193\n1\n3,000\n2014\n100\n2\nPower Doors\n29\nBldg 102\n1\n3,000\n2016\n100\n1\nPower Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n2200 Fort Roots Drive, North Little Rock, AR\nFreight Hydraulic Elevators\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n7\nBldg 76\n1\n2,500\n1980\n30\n1\nPower Doors\n10\nBldg 159\n1\n6,000\n1969\n50\n1\nPower Doors\n23\nBldg 182\n1\n10,000\n1982\n50\n1\nPower Doors\n26\nBldg 7\n1\n1,200\n1965\nUnknown\n3\nManual Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n2200 Fort Roots Drive, North Little Rock, AR\nWheelchair Lift\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n30\nBldg 33 HR\n1\n500\n1986\n3\nN/A\nManual Doors\n\nAll safety inspections shall be made in accordance with the latest revised edition of the American Society of Mechanical Engineers (ASME) Safety Code for Elevators and Escalators manual A17.1 Section X, A17.2, A17.3, A17.4, A17.5, A18.1 most recent edition the most current publication will be used at all times.\nWORK HOURS AND SCHEDULING ARRANGEMENTS\nAnnual safety test will be made during the contract period of performance on the proposal schedule for elevators/dumbwaiters at each CAVHS Medical Center for the base period and four (4) twelve (12) month renewal option periods. All elevators will require inspections, including but not limited to annual no-load, slow-speed safety tests of car safeties, governors, and buffers; Annual Firefighter s Service operation tests, annual standby power operation tests, battery pack lowering and car emergency lighting, pressure relief valve tests, and 5-year full load, full speed tests of car safeties.\nInspections shall be conducted in accordance with ASME A17.1 Safety Code for Elevators and Escalators and shall be based on the code edition in effect at the time when elevators were installed or modernized.\nAll inspections shall be coordinated with the CAVHS s Facilities Manager and/or Contracting Officers Representative (COR). The inspector shall also coordinate inspections and inspection time frames with the appropriate elevator maintenance contractor currently under contract with the VA. The COR at the medical center shall accompany the contractor as an observer during the entire time of each inspection. The VA Medical Center s COR shall be notified in writing no less than 15 calendar days prior to the scheduled inspection. Upon arrival to perform inspection, all service contract personnel must check in and out before providing services. Location for checking in and out during normal business hours will be indicated at the time of award. Service tickets must be signed and dated, indicating work complete or incomplete.\nThe inspector shall not proceed to the inspection site until the schedule has been agreed upon and coordinated with all parties involved in the scheduling process. All work shall be performed during regular working hours of the elevator trade, Monday through Friday, 7:00 AM to 3:30 PM, excluding government holidays. Inspection that may severely impact elevator service, or incapacitate a bank of elevators, shall be performed after normal working hours, i.e., firefighters' service, emergency control systems, etc. All work performed outside of regular working hours shall be approved in advance by the COR.  Work will not be scheduled or performed on federal holidays. The Federal Holidays, which are observed by the federal government, are annotated below.\n \nNew Year s Day     January 1\nMartin Luther King s Birthday   Third Monday in January\nPresident s Day     Third Monday in February\nMemorial Day     Last Monday in May\nJuneteenth      June 19\nIndependence Day     July 4\nLabor Day      First Monday in September\nColumbus Day     Second Monday in October\nVeterans Day     November 11\nThanksgiving Day     Fourth Thursday in November\nChristmas Day     December 25\n\nAny other day specifically declared to be a national holiday (per Federal Statute, Executive Order, or by the President s Proclamation). \nShould after-hour inspections be required, the Government will pay the difference between the straight time hourly labor rate and the overtime rate as established on the pricing schedule. Overtime work shall receive prior approval from the COR. Overtime hours will be computed between the hours of 3:29 PM and 6:59 AM, Monday through Friday. Weekend work will be paid at the full overtime rate as established on the proposal Schedule. The full overtime rate will apply for work performed during the following National holidays: Labor Day, Christmas, New Year's, Thanksgiving, Memorial Day, and Independence Day. Inspections performed during other Government holidays will be paid at the straight-time hourly rate.\nInspections that require a return visit to the work site due to unforeseen problems that cause a delay in the inspection process shall be addressed to the Contracting Officer and COR on a case-by-case basis. The contractor may be reimbursed for additional time spent on the job site; however, the cost for additional man-hours shall be negotiated with the Contracting Officer before starting work. Reimbursement shall be based on the price per man-hour for inspection time as reflected in the price proposal schedule.\n\nSCOPE\nThe vendor shall provide all inspection, engineering, management, supervision, manpower, materials, supplies, equipment, travel and all costs to and from, to plan, schedule, coordinate and assure effective performance of all inspection services for the elevators and other vertical transport equipment.  Any changes to this contract shall be reflected in a written modification to this contract, signed by the contractor and the Contracting Officer.\nThe contractor in question must be certified by the Elevator Safety Division at Arkansas Department of Labor and Licensing. The contractor shall furnish all qualified/certified personnel, materials, equipment, and services to include lodging, travel, and meals necessary to perform the following scope of work.   The contractor will witness annual safety tests and five-year load tests on electric and three-year pressure tests on hydraulic elevators and dumbwaiters. These specifications cover the annual inspections of electric or hydraulic elevators and dumbwaiters, the annual tests of governor and safety devices, on all facility elevators and dumbwaiters during the period indicated in the proposal schedule for the base year period and a total of four (4) renewal option periods. Inspections and documentation shall be in accordance with the American National Standard Safety Code (ANSI), NFPA 70 National Electric Code and the American Society of Mechanical Engineers (ASME) Safety Code for Elevators and Escalators manual A17.1 Section X, A17.2, A17.3, A17.4, A17.5, A18.1 most recent edition the most current publication will be used at all times.\nAt a minimum, the inspector shall maintain a library of the following publications applicable to the type of inspection being conducted:\nASME A17.1, Safety Code for Elevators and Escalators\nASME A17.5, Elevator and Escalator Electrical Equipment.\nASME A17.2, Inspector s Guide for Inspection of Elevators, Escalators and Moving Walks. \nASME A17.3, Safety Code for Existing Elevators and Escalators.\nA17.1 Handbook   Safety Code for Elevators and Escalators.\nNFPA 70 (National Electric Code)\nApplicable IBC and NFPA code books.\nASME A18.1, Safety Standard for Platform Lifts and Stairway Chairlifts.\nIt is the responsibility of the inspector to determine if the equipment is in a safe operating condition, that it has not been altered except in conformity to the applicable codes or regulations, and that each elevator will perform in accordance with all applicable inspection requirements.\nANNUAL SAFETY INSPECTION\nAn annual safety inspection will be performed on elevators/dumbwaiters.  Safeties shall be subjected to an annual running test per the recommended guidelines as indicated by ANSI/ASME A17.1.\nThe slowest operating speed, at no load test required for annual test as indicated in the Safety test instructions on VISN 15 Report of Test of Elevator Governor and Safety Devices (see Attachment A)\nThe elevator maintenance company is required to furnish the tools and labor to perform the annual no-load tests. The inspection contractor will witness and certify the inspection.\nPhase I Lobby Key Switch (maintenance and fire service personnel system verification checks) recall by use of the key switch, and a minimum of one-floor operation on Phase II Service check should be accomplished during the annual safety check.\nInspections are to be made in accordance with the American National Standard Safety Code for Elevators and Escalators manual, ANSI/ASME A17.1 Section X, latest edition. Elevators are to be run at a slow speed.\nFIVE (5) YEAR SAFETY TEST/THREE (3) YEAR PRESSURE\nA five-year safety test will be performed on the elevators and dumbwaiters listed. Safeties shall be subjected to the ASME testing standards for car and counterweights, safeties, governors, and oil buffers. All work is to be performed in accordance with Rule 1002.3, 5-year inspection test requirements, ASME A17.1, latest edition.\nAt a minimum, elevators/dumbwaiters at all stations should have the following inspection points covered in accordance with ASME A17.1 Section X, plus A17.2 for the full load tests:\nTest the car safety devices and overspeed governor with 100% contract load at speed.\nTest the car brake and emergency power operation with 125% contract load.\nTesting and calibration of the overspeed governor jaw and overspeed switch tripping speeds.\nAttach metal test tags. Seal and tag all safety devices and oil buffers.\nTest the oil buffers in the following manner:\nrunning onto the car buffers with contract load at inspection speed.\nrunning onto the counterweight buffers with the car empty running at inspection speed in the up direction.\nTest terminal, normal and emergency limits.\nTest leveling zone and leveling speeds with contract load.\nTest the door pressure and kinetic energy.\nTest the governor pull-through tension.\nRecord the following: capacity, speed empty up and down, speed loaded up and down, safety jaw tripping speed, overspeed governor tripping speed, safety slide on the rails, governor pull through, governor plate speed, car level after test, buffer return time, complete firefighters service check as applicable, and safety rope pull out as applicable.\nPerform all inspections and tests in strict accordance with ANSI/ASME A17.1, Section X plus A 17.2.\nList code violations observed during tests.\nA five-year load test is required based on DIV II - 210.2.\nTesting requires 50 lb. test weights. \nThe elevator maintenance company is required to furnish weights, tools, and labor to perform the five-year full load test. The elevator inspection contractor will witness and certify the inspection.\nThe contractor will perform a three-year pressure test on all hydraulic elevators IAW ASME A17.1 latest edition.\n\nWORKMANSHIP\nAll inspections shall be conducted professionally and thoroughly.  All inspections, workmanship, or equipment shall be subject to re-inspection, examination, and test by Government inspectors at all times during the course of the work and at all places where such work is being conducted.  The Government shall have the right to reject defective inspections or reports.  Rejected inspections or reports shall be satisfactorily corrected and/or replaced without additional expense to the Government.\nCERTIFICATE OF INSPECTION:\nThe inspector shall, upon completion of inspection, ensure that the inspector s signature and date are entered on the Government-furnished Certificate of Elevator Inspection. Certificates for elevators are to be posted on file in the Facilities Management Office.\n\nShould the inspector, using professional judgment, believe the elevator to be unsafe at the time of inspection, he or she may, at his or her discretion, shut the elevator down until corrective action is taken. Elevator service shall not be restored until the deficiencies have been corrected and the elevator is re-inspected and found suitable for use.\n\nDELIVERABLES (INSPECTION AND TEST REPORTS)\nInspector shall use the ASME Elevator Inspection Checklist as a guide for inspection purposes. 5-year full load test forms shall be provided by the inspector and approved by the COR. A separate test form and checklist shall be provided for each elevator inspected. When inspections are completed, the inspector shall compile a comprehensive narrative report with findings and recommendations, including deficiencies and recommended corrective action. Code-specific items should also be noted on the report with reference to code rules. The report shall be done professionally, typewritten, signed, and dated by the inspector. The contractor shall have the capability to distribute reports electronically via email.\nReports and checklists shall be submitted within ten (10) calendar days after completion of an inspection. Safety deficiencies or any items that require immediate attention shall be reported right away to the Facilities Manager at the Medical Center or COR for corrective action.\nThe contractor shall complete a full report upon completion of the inspection. For all items on such forms that are not applicable, the notation \"NA\" (not applicable) shall be made. On the reverse side of such forms, the contractor shall clearly indicate any adjustments, repairs, or replacements necessary to correct troubles encountered, shall definitively justify such recommendations, and shall furnish specifications sufficient to enable VA to purchase the materials required for such purposes (and cost estimate if available). Also, on the reverse side of the forms, the contractor shall advise whether the elevator parts have been kept clean and lubricated where necessary.\n\nSAFETY REQUIREMENTS\nIn the performance of this contract, the Contractor shall take such safety precautions as the Contracting Officer or his designee may determine to be reasonably necessary to protect the lives and health of occupants of the building. The Contracting Officer or COR will notify the Contractor of any noncompliance with the foregoing provisions and the action to be taken.\n\nThe Contractor shall, after receipt of such notice, immediately correct the conditions to which attention has been directed. Such notice, when served on the Contractor or his representative at the site of work, shall be deemed sufficient for the purpose aforesaid. If the Contractor fails or refuses to comply promptly, the Contacting Officer may issue an order, stopping all or any part of the work, and hold the Contractor in default in accordance with the Default clause in this contract.\n\nQUALITY PERFORMANCE STANDARD\nElevator inspectors and consultants shall meet the ASME QEI-1 standard in addition to being certified by the Elevator Safety Division at the Arkansas Department of Labor and Licensing. Inspectors and/or consultants shall also have a minimum of five (5) years of practical field experience in the vertical transportation industry at the journeyman level. A professional engineering license is considered journeyman level, provided the engineer has five (5) years  experience in the elevator field. All offers must include documentation and proof of the above certifications and qualifications.\nPursuant to ANSI/ASME A17.1 Section 1000, ASME A17.2, ASME A17.3 the Contractor must provide proof of QE-1 certification. A copy of this certificate must be provided with the proposal. A copy of the Inspector s QEI credentials shall be current and provided to the COR. Credentials shall be kept on file in the Facilities Elevator Inspection File at each Facilities Management Office location.\nInspectors and/or consultants shall be able to communicate effectively both orally and in writing and possess the skills necessary to prepare professionally written comprehensive narrative reports, specifications, and cost estimates.\nContractor shall submit a quality control plan within thirty (30) calendar days after notice to proceed, consisting of a plan as to what standard their company holds their inspectors to, and the frequency at which their work is checked.\n\nINSPECTION AND TESTING SERVICES\nElevator Safety Inspections\nThe independent VA contract inspector shall witness the annual safety test and five (5) year load tests on electric or hydraulic elevators and dumbwaiters in accordance with the requirements of the latest edition of /ASMI QEI-1, Standard for the Qualification of Elevator Inspectors. The contractor shall provide personnel who are familiar with the equipment to perform tests and assist the inspector. \n\nThe contractor shall schedule and have performed the periodic inspections and tests of all elevators at the recommended intervals found in the effective edition of ANSI/ASME A17. The maintenance contractor must coordinate the performance of the safety inspections with the independent VA.\n\nThe contractor shall furnish a copy of the inspection schedule to the COR (this list shall be estimated for proposal submission and finalized before award of the contract. This schedule shall clearly indicate the edition of ANSI/ASME A17. The COR will be advised of any changes to the schedule and notified fifteen (15) working days in advance of the inspection date to allow the COR to observe the inspection. The required annual inspection of the emergency signaling device (alarm) and the means of two-way conversation will be recorded on an approved form. Copies of this form will be provided to the contractor by the COR.\n\nThe contractor shall provide a qualified employee to accompany the inspector during the inspection.\n\nThe Independent VA Contract Inspector shall furnish a written report of each inspection to the COR and to the maintenance contractor. The report shall be submitted on the following checklists from the American Society of Mechanical Engineers (ASME): Checklist for Inspection of Electric Elevators, Checklist for Inspection of Hydraulic Elevators, as appropriate. The maintenance contractor shall be responsible for the correction of all listed deficiencies within the scope of the contract by the date specified by the COR. Any deficiencies marked \"emergency\" must be corrected immediately. When all listed deficiencies have been corrected the contractor shall sign and date the inspection report and return it to the COR.\nThe contractor shall be responsible for obtaining the signed form from the independent VA contractor elevator inspector.  Copies of the form will be provided to the Contracting Officer and COR.\n\nThe following information is requested in response to this SSN:\nGeneral Company Information:\nName of Company:\nAddress:\nPoint of Contact:\nPhone Number:\nEmail Address:\nCompany Website (if available):\nSAM Unique Entity Identifier Number:\nCommercial & Government Entity (CAGE) Number:\nBusiness Type (Socio-economic status as it relates to 238290). Please ensure the System\nfor Award Management (SAM   sam.gov) indicates this NAICS code if you are\ninterested in the requirement. Please put a check mark or X next to the type of business\nyou are below:\nLarge\n8(a)\nHUBZone\nSmall Business\nSmall Disadvantaged Business\nWoman-Owned Small Business\nService-Disabled Veteran-Owned Small Business\nVeteran-Owned Small Business\n***Note: All Veteran-Owned Businesses must be registered in SBA Veteran Small\nBusiness Certification at Veteran Small Business Certification (sba.gov) to be\nconsidered a Veteran Owned Business. Socioeconomic status (whether Service Disabled\nVeteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VSOB),\nHUBZone, 8(a), Woman Owned, Small Disadvantaged, etc.).\n\nIf small, does your firm qualify as a small, emerging business, or small disadvantaged\nbusiness? For all small businesses, including SDVOSB and VOSB, at least fifty (50)\npercent of the cost of contract performance incurred for personnel shall be expended for\nemployees of the concern.\n\nIf disadvantaged, specify under which disadvantaged group, and if your firm is certified\nunder Section 8(a) of the Small Business Act. ***\nIs this service available under a federal supply schedule (GSA)? If yes, please provide\nthe contract number.\nAre you an authorized distributor/reseller?  Must provide OEM authorization with SSN response.\nIs your (Contractor) Trade Agreement Certificate completed in SAM?  Please provide evidence with a response.\nDoes the contractor possess the training and certification required to perform the startup and commissioning services with the OEM specifications and guidelines?\nContractors shall provide an estimated industry pricing for the product for market research and budgetary purposes.\nDoes the contractor have access to OEM parts for potential repairs?\nIs the contractor licensed in the State of Arkansas by the Elevator Safety Division at the Arkansas Department of Labor and Licensing?\n\nProvide descriptive literature demonstrating the ability to meet the SOW requirements/salient characteristics listed for the product being offered.  Please provide a list of contracts for commercial, federal, state, and local governments.  Listed contracts shall provide communication on the government requirement, illustrating the capability for comparison to the product meeting the specific requirements per the draft SOW.\n\nAll responses to this Sources Sought Notice should be emailed to carmyn.williams@va.gov.  All responses are due by 10:00 AM on Tuesday, 10 February 2026.","text":"Sources Sought Notice (SSN)\n\nDepartment of Veterans Affairs, Veterans Health Administration, Network Contracting Office 16\n(NCO16)\n\nThis SSN is for market research and planning purposes only and shall not be considered an\nInvitation for Bid (IFB), Request for Task Execution Plan, Request for Quotation (RFQ), or a\nRequest for Proposal (RFP). Additionally, there is no obligation on the part of the Government to\nacquire any products or services described in this SSN. Your response to this SSN will be treated\nonly as information for the Government to consider. You will not be entitled to payment for\ndirect or indirect costs that you incur in responding to this SSN. This request does not constitute\na solicitation for proposals or the authority to enter negotiations to award a contract. No funds\nhave been authorized, appropriated, or received for this effort. Interested parties are responsible for adequately marking proprietary, restricted, or competition-sensitive information contained in their response. The Government does not intend to pay for the information submitted in response to this SSN.\n\nThe North American Industry Classification System (NAICS) for this requirement is 238290\nwith a size standard of $22.0 Million and Product Service Code (PSC) of H330.\n\nPlease note that this is a draft Statement of Work.\n\nDRAFT STATEMENT OF WORK (SOW)\nElevator Inspection\nElevator safety inspections for all traction and hydraulic elevators located at Central Arkansas Veterans Healthcare System (CAVHS) in Little Rock and North Little Rock, AR. The elevator maintenance contractor under contract with the CAVHS at the specific building location will be present and assist in the inspection and testing. The elevator maintenance contractor will provide the necessary expertise, manpower, test weights, gauges, dynamometers, etc., to perform the various inspections and tests required by code. The elevator inspector shall provide door pressure gauges, stopwatches, calipers, flashlights, and other small hand tools necessary to conduct inspections.\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n4300 West 7th Street, Little Rock, AR\nPassenger Cab Elevators\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n1\nP-1\n1\n4,000\n1984\n500\n8\nPower Doors\n2\nP-2\n1\n4,000\n1984\n500\n8\nPower Doors\n3\nP-3\n1\n4,000\n1984\n500\n8\nPower Doors\n4\nP-4\n1\n4,000\n1984\n500\n8\nPower Doors\n5\nP-5\n1\n4,000\n1984\n500\n8\nPower Doors\n6\nS-1\n1\n5,000\n1984\n500\n8\nPower Doors\n7\nS-2\n1\n5,000\n1984\n500\n8\nPower Doors\n8\nS-3\n1\n5,000\n1984\n500\n8\nPower Doors\n9\nS-4\n1\n5,000\n1984\n500\n8\nPower Doors\n10\nS-5\n1\n5,000\n1984\n500\n8\nPower Doors\n17\nVA-UAMS\n1\n4,500\n1984\n150\n1\nPower Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n4300 West 7th Street, Little Rock, AR\nCart Lift\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n11\nCartlift-1\n1\n300\n1984\n300\n8\nManual Doors\n12\nCartlift-2\n1\n300\n1984\n200\n8\nManual Doors\n13\nCartlift-3\n1\n300\n1984\n300\n8\nManual Doors\n14\nCartlift-4\n1\n300\n1984\n200\n8\nManual Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n4300 West 7th Street, Little Rock, AR\nDumbwaiter\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n15\nDW-1\n1\n300\n1984\n200\n8\nManual Doors\n16\nDW-2\n1\n300\n1984\n200\n8\nManual Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n4300 West 7th Street, Little Rock, AR\nPassenger Hydraulic Elevator\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n18\nMICU/1F\n1\n5,000\n2003\n100\n1\nPower Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n2200 Fort Roots Drive, North Little Rock, AR\nPassenger Cab Elevators\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n1\nBldg 58\n1\n3,500\n1965\n200\n3\nPower Doors\n2\nBldg 65\n1\n3,500\n1990\n200\n3\nPower Doors\n4\nBldg 66\n1\n3,500\n1968\n200\n3\nPower Doors\n6\nBldg 68\n1\n3,500\nUnknown\n200\n3\nPower Doors\n9\nBldg 111\n1\n3,500\n1966\n100\n3\nPower Doors\n11\nBldg 170\n1\n3,500\n1982\n350\n4\nPower Doors\n12\nBldg 170\n1\n4,000\n1982\n350\n4\nPower Doors\n13\nBldg 170\n1\n4,000\n1982\n350\n4\nPower Doors\n14\nBldg 170\n1\n4,000\n1982\n350\n4\nPower Doors\n15\nBldg 170\n1\n4,000\n1982\n350\n4\nPower Doors\n16\nBldg 170\n1\n5,000\n1982\n350\n4\nPower Doors\n17\nBldg 170\n1\n5,000\n1982\n350\n4\nPower Doors\n18\nBldg 170\n1\n5,000\n1982\n350\n4\nPower Doors\n19\nBldg 170\n1\n5,000\n1982\n350\n4\nPower Doors\n20\nBldg 170\n1\n5,000\n1982\n100\n4\nPower Doors\n21\nBldg 170\n1\n5,000\n1982\n350\n4\nPower Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n2200 Fort Roots Drive, North Little Rock, AR\nPassenger Hydraulic Elevators\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n3\nBldg 65\n1\n4,000\nUnknown\n150\n3\nPower Doors\n5\nBldg 66\n1\n4,000\nUnknown\n125\n3\nPower Doors\n8\nBldg 103\n1\n2,500\n1989\n125\n3\nPower Doors\n22\nBldg 170\n1\n5,000\n1982\n350\n4\nPower Doors\n24\nBldg 190\n1\n2,500\n1994\n125\n3\nPower Doors\n25\nBldg 190\n1\n2,500\n2011\n100\n3\nPower Doors\n27\nBldg 89\n1\n2,000\n2002\n100\n2\nPower Doors\n28\nBldg 193\n1\n3,000\n2014\n100\n2\nPower Doors\n29\nBldg 102\n1\n3,000\n2016\n100\n1\nPower Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n2200 Fort Roots Drive, North Little Rock, AR\nFreight Hydraulic Elevators\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n7\nBldg 76\n1\n2,500\n1980\n30\n1\nPower Doors\n10\nBldg 159\n1\n6,000\n1969\n50\n1\nPower Doors\n23\nBldg 182\n1\n10,000\n1982\n50\n1\nPower Doors\n26\nBldg 7\n1\n1,200\n1965\nUnknown\n3\nManual Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n2200 Fort Roots Drive, North Little Rock, AR\nWheelchair Lift\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n30\nBldg 33 HR\n1\n500\n1986\n3\nN/A\nManual Doors\n\nAll safety inspections shall be made in accordance with the latest revised edition of the American Society of Mechanical Engineers (ASME) Safety Code for Elevators and Escalators manual A17.1 Section X, A17.2, A17.3, A17.4, A17.5, A18.1 most recent edition the most current publication will be used at all times.\nWORK HOURS AND SCHEDULING ARRANGEMENTS\nAnnual safety test will be made during the contract period of performance on the proposal schedule for elevators/dumbwaiters at each CAVHS Medical Center for the base period and four (4) twelve (12) month renewal option periods. All elevators will require inspections, including but not limited to annual no-load, slow-speed safety tests of car safeties, governors, and buffers; Annual Firefighter s Service operation tests, annual standby power operation tests, battery pack lowering and car emergency lighting, pressure relief valve tests, and 5-year full load, full speed tests of car safeties.\nInspections shall be conducted in accordance with ASME A17.1 Safety Code for Elevators and Escalators and shall be based on the code edition in effect at the time when elevators were installed or modernized.\nAll inspections shall be coordinated with the CAVHS s Facilities Manager and/or Contracting Officers Representative (COR). The inspector shall also coordinate inspections and inspection time frames with the appropriate elevator maintenance contractor currently under contract with the VA. The COR at the medical center shall accompany the contractor as an observer during the entire time of each inspection. The VA Medical Center s COR shall be notified in writing no less than 15 calendar days prior to the scheduled inspection. Upon arrival to perform inspection, all service contract personnel must check in and out before providing services. Location for checking in and out during normal business hours will be indicated at the time of award. Service tickets must be signed and dated, indicating work complete or incomplete.\nThe inspector shall not proceed to the inspection site until the schedule has been agreed upon and coordinated with all parties involved in the scheduling process. All work shall be performed during regular working hours of the elevator trade, Monday through Friday, 7:00 AM to 3:30 PM, excluding government holidays. Inspection that may severely impact elevator service, or incapacitate a bank of elevators, shall be performed after normal working hours, i.e., firefighters' service, emergency control systems, etc. All work performed outside of regular working hours shall be approved in advance by the COR. Work will not be scheduled or performed on federal holidays. The Federal Holidays, which are observed by the federal government, are annotated below.\n\nNew Year s Day January 1\nMartin Luther King s Birthday Third Monday in January\nPresident s Day Third Monday in February\nMemorial Day Last Monday in May\nJuneteenth June 19\nIndependence Day July 4\nLabor Day First Monday in September\nColumbus Day Second Monday in October\nVeterans Day November 11\nThanksgiving Day Fourth Thursday in November\nChristmas Day December 25\n\nAny other day specifically declared to be a national holiday (per Federal Statute, Executive Order, or by the President s Proclamation).\nShould after-hour inspections be required, the Government will pay the difference between the straight time hourly labor rate and the overtime rate as established on the pricing schedule. Overtime work shall receive prior approval from the COR. Overtime hours will be computed between the hours of 3:29 PM and 6:59 AM, Monday through Friday. Weekend work will be paid at the full overtime rate as established on the proposal Schedule. The full overtime rate will apply for work performed during the following National holidays: Labor Day, Christmas, New Year's, Thanksgiving, Memorial Day, and Independence Day. Inspections performed during other Government holidays will be paid at the straight-time hourly rate.\nInspections that require a return visit to the work site due to unforeseen problems that cause a delay in the inspection process shall be addressed to the Contracting Officer and COR on a case-by-case basis. The contractor may be reimbursed for additional time spent on the job site; however, the cost for additional man-hours shall be negotiated with the Contracting Officer before starting work. Reimbursement shall be based on the price per man-hour for inspection time as reflected in the price proposal schedule.\n\nSCOPE\nThe vendor shall provide all inspection, engineering, management, supervision, manpower, materials, supplies, equipment, travel and all costs to and from, to plan, schedule, coordinate and assure effective performance of all inspection services for the elevators and other vertical transport equipment. Any changes to this contract shall be reflected in a written modification to this contract, signed by the contractor and the Contracting Officer.\nThe contractor in question must be certified by the Elevator Safety Division at Arkansas Department of Labor and Licensing. The contractor shall furnish all qualified/certified personnel, materials, equipment, and services to include lodging, travel, and meals necessary to perform the following scope of work. The contractor will witness annual safety tests and five-year load tests on electric and three-year pressure tests on hydraulic elevators and dumbwaiters. These specifications cover the annual inspections of electric or hydraulic elevators and dumbwaiters, the annual tests of governor and safety devices, on all facility elevators and dumbwaiters during the period indicated in the proposal schedule for the base year period and a total of four (4) renewal option periods. Inspections and documentation shall be in accordance with the American National Standard Safety Code (ANSI), NFPA 70 National Electric Code and the American Society of Mechanical Engineers (ASME) Safety Code for Elevators and Escalators manual A17.1 Section X, A17.2, A17.3, A17.4, A17.5, A18.1 most recent edition the most current publication will be used at all times.\nAt a minimum, the inspector shall maintain a library of the following publications applicable to the type of inspection being conducted:\nASME A17.1, Safety Code for Elevators and Escalators\nASME A17.5, Elevator and Escalator Electrical Equipment.\nASME A17.2, Inspector s Guide for Inspection of Elevators, Escalators and Moving Walks.\nASME A17.3, Safety Code for Existing Elevators and Escalators.\nA17.1 Handbook Safety Code for Elevators and Escalators.\nNFPA 70 (National Electric Code)\nApplicable IBC and NFPA code books.\nASME A18.1, Safety Standard for Platform Lifts and Stairway Chairlifts.\nIt is the responsibility of the inspector to determine if the equipment is in a safe operating condition, that it has not been altered except in conformity to the applicable codes or regulations, and that each elevator will perform in accordance with all applicable inspection requirements.\nANNUAL SAFETY INSPECTION\nAn annual safety inspection will be performed on elevators/dumbwaiters. Safeties shall be subjected to an annual running test per the recommended guidelines as indicated by ANSI/ASME A17.1.\nThe slowest operating speed, at no load test required for annual test as indicated in the Safety test instructions on VISN 15 Report of Test of Elevator Governor and Safety Devices (see Attachment A)\nThe elevator maintenance company is required to furnish the tools and labor to perform the annual no-load tests. The inspection contractor will witness and certify the inspection.\nPhase I Lobby Key Switch (maintenance and fire service personnel system verification checks) recall by use of the key switch, and a minimum of one-floor operation on Phase II Service check should be accomplished during the annual safety check.\nInspections are to be made in accordance with the American National Standard Safety Code for Elevators and Escalators manual, ANSI/ASME A17.1 Section X, latest edition. Elevators are to be run at a slow speed.\nFIVE (5) YEAR SAFETY TEST/THREE (3) YEAR PRESSURE\nA five-year safety test will be performed on the elevators and dumbwaiters listed. Safeties shall be subjected to the ASME testing standards for car and counterweights, safeties, governors, and oil buffers. All work is to be performed in accordance with Rule 1002.3, 5-year inspection test requirements, ASME A17.1, latest edition.\nAt a minimum, elevators/dumbwaiters at all stations should have the following inspection points covered in accordance with ASME A17.1 Section X, plus A17.2 for the full load tests:\nTest the car safety devices and overspeed governor with 100% contract load at speed.\nTest the car brake and emergency power operation with 125% contract load.\nTesting and calibration of the overspeed governor jaw and overspeed switch tripping speeds.\nAttach metal test tags. Seal and tag all safety devices and oil buffers.\nTest the oil buffers in the following manner:\nrunning onto the car buffers with contract load at inspection speed.\nrunning onto the counterweight buffers with the car empty running at inspection speed in the up direction.\nTest terminal, normal and emergency limits.\nTest leveling zone and leveling speeds with contract load.\nTest the door pressure and kinetic energy.\nTest the governor pull-through tension.\nRecord the following: capacity, speed empty up and down, speed loaded up and down, safety jaw tripping speed, overspeed governor tripping speed, safety slide on the rails, governor pull through, governor plate speed, car level after test, buffer return time, complete firefighters service check as applicable, and safety rope pull out as applicable.\nPerform all inspections and tests in strict accordance with ANSI/ASME A17.1, Section X plus A 17.2.\nList code violations observed during tests.\nA five-year load test is required based on DIV II - 210.2.\nTesting requires 50 lb. test weights.\nThe elevator maintenance company is required to furnish weights, tools, and labor to perform the five-year full load test. The elevator inspection contractor will witness and certify the inspection.\nThe contractor will perform a three-year pressure test on all hydraulic elevators IAW ASME A17.1 latest edition.\n\nWORKMANSHIP\nAll inspections shall be conducted professionally and thoroughly. All inspections, workmanship, or equipment shall be subject to re-inspection, examination, and test by Government inspectors at all times during the course of the work and at all places where such work is being conducted. The Government shall have the right to reject defective inspections or reports. Rejected inspections or reports shall be satisfactorily corrected and/or replaced without additional expense to the Government.\nCERTIFICATE OF INSPECTION:\nThe inspector shall, upon completion of inspection, ensure that the inspector s signature and date are entered on the Government-furnished Certificate of Elevator Inspection. Certificates for elevators are to be posted on file in the Facilities Management Office.\n\nShould the inspector, using professional judgment, believe the elevator to be unsafe at the time of inspection, he or she may, at his or her discretion, shut the elevator down until corrective action is taken. Elevator service shall not be restored until the deficiencies have been corrected and the elevator is re-inspected and found suitable for use.\n\nDELIVERABLES (INSPECTION AND TEST REPORTS)\nInspector shall use the ASME Elevator Inspection Checklist as a guide for inspection purposes. 5-year full load test forms shall be provided by the inspector and approved by the COR. A separate test form and checklist shall be provided for each elevator inspected. When inspections are completed, the inspector shall compile a comprehensive narrative report with findings and recommendations, including deficiencies and recommended corrective action. Code-specific items should also be noted on the report with reference to code rules. The report shall be done professionally, typewritten, signed, and dated by the inspector. The contractor shall have the capability to distribute reports electronically via email.\nReports and checklists shall be submitted within ten (10) calendar days after completion of an inspection. Safety deficiencies or any items that require immediate attention shall be reported right away to the Facilities Manager at the Medical Center or COR for corrective action.\nThe contractor shall complete a full report upon completion of the inspection. For all items on such forms that are not applicable, the notation \"NA\" (not applicable) shall be made. On the reverse side of such forms, the contractor shall clearly indicate any adjustments, repairs, or replacements necessary to correct troubles encountered, shall definitively justify such recommendations, and shall furnish specifications sufficient to enable VA to purchase the materials required for such purposes (and cost estimate if available). Also, on the reverse side of the forms, the contractor shall advise whether the elevator parts have been kept clean and lubricated where necessary.\n\nSAFETY REQUIREMENTS\nIn the performance of this contract, the Contractor shall take such safety precautions as the Contracting Officer or his designee may determine to be reasonably necessary to protect the lives and health of occupants of the building. The Contracting Officer or COR will notify the Contractor of any noncompliance with the foregoing provisions and the action to be taken.\n\nThe Contractor shall, after receipt of such notice, immediately correct the conditions to which attention has been directed. Such notice, when served on the Contractor or his representative at the site of work, shall be deemed sufficient for the purpose aforesaid. If the Contractor fails or refuses to comply promptly, the Contacting Officer may issue an order, stopping all or any part of the work, and hold the Contractor in default in accordance with the Default clause in this contract.\n\nQUALITY PERFORMANCE STANDARD\nElevator inspectors and consultants shall meet the ASME QEI-1 standard in addition to being certified by the Elevator Safety Division at the Arkansas Department of Labor and Licensing. Inspectors and/or consultants shall also have a minimum of five (5) years of practical field experience in the vertical transportation industry at the journeyman level. A professional engineering license is considered journeyman level, provided the engineer has five (5) years experience in the elevator field. All offers must include documentation and proof of the above certifications and qualifications.\nPursuant to ANSI/ASME A17.1 Section 1000, ASME A17.2, ASME A17.3 the Contractor must provide proof of QE-1 certification. A copy of this certificate must be provided with the proposal. A copy of the Inspector s QEI credentials shall be current and provided to the COR. Credentials shall be kept on file in the Facilities Elevator Inspection File at each Facilities Management Office location.\nInspectors and/or consultants shall be able to communicate effectively both orally and in writing and possess the skills necessary to prepare professionally written comprehensive narrative reports, specifications, and cost estimates.\nContractor shall submit a quality control plan within thirty (30) calendar days after notice to proceed, consisting of a plan as to what standard their company holds their inspectors to, and the frequency at which their work is checked.\n\nINSPECTION AND TESTING SERVICES\nElevator Safety Inspections\nThe independent VA contract inspector shall witness the annual safety test and five (5) year load tests on electric or hydraulic elevators and dumbwaiters in accordance with the requirements of the latest edition of /ASMI QEI-1, Standard for the Qualification of Elevator Inspectors. The contractor shall provide personnel who are familiar with the equipment to perform tests and assist the inspector.\n\nThe contractor shall schedule and have performed the periodic inspections and tests of all elevators at the recommended intervals found in the effective edition of ANSI/ASME A17. The maintenance contractor must coordinate the performance of the safety inspections with the independent VA.\n\nThe contractor shall furnish a copy of the inspection schedule to the COR (this list shall be estimated for proposal submission and finalized before award of the contract. This schedule shall clearly indicate the edition of ANSI/ASME A17. The COR will be advised of any changes to the schedule and notified fifteen (15) working days in advance of the inspection date to allow the COR to observe the inspection. The required annual inspection of the emergency signaling device (alarm) and the means of two-way conversation will be recorded on an approved form. Copies of this form will be provided to the contractor by the COR.\n\nThe contractor shall provide a qualified employee to accompany the inspector during the inspection.\n\nThe Independent VA Contract Inspector shall furnish a written report of each inspection to the COR and to the maintenance contractor. The report shall be submitted on the following checklists from the American Society of Mechanical Engineers (ASME): Checklist for Inspection of Electric Elevators, Checklist for Inspection of Hydraulic Elevators, as appropriate. The maintenance contractor shall be responsible for the correction of all listed deficiencies within the scope of the contract by the date specified by the COR. Any deficiencies marked \"emergency\" must be corrected immediately. When all listed deficiencies have been corrected the contractor shall sign and date the inspection report and return it to the COR.\nThe contractor shall be responsible for obtaining the signed form from the independent VA contractor elevator inspector. Copies of the form will be provided to the Contracting Officer and COR.\n\nThe following information is requested in response to this SSN:\nGeneral Company Information:\nName of Company:\nAddress:\nPoint of Contact:\nPhone Number:\nEmail Address:\nCompany Website (if available):\nSAM Unique Entity Identifier Number:\nCommercial & Government Entity (CAGE) Number:\nBusiness Type (Socio-economic status as it relates to 238290). Please ensure the System\nfor Award Management (SAM sam.gov) indicates this NAICS code if you are\ninterested in the requirement. Please put a check mark or X next to the type of business\nyou are below:\nLarge\n8(a)\nHUBZone\nSmall Business\nSmall Disadvantaged Business\nWoman-Owned Small Business\nService-Disabled Veteran-Owned Small Business\nVeteran-Owned Small Business\n***Note: All Veteran-Owned Businesses must be registered in SBA Veteran Small\nBusiness Certification at Veteran Small Business Certification (sba.gov) to be\nconsidered a Veteran Owned Business. Socioeconomic status (whether Service Disabled\nVeteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VSOB),\nHUBZone, 8(a), Woman Owned, Small Disadvantaged, etc.).\n\nIf small, does your firm qualify as a small, emerging business, or small disadvantaged\nbusiness? For all small businesses, including SDVOSB and VOSB, at least fifty (50)\npercent of the cost of contract performance incurred for personnel shall be expended for\nemployees of the concern.\n\nIf disadvantaged, specify under which disadvantaged group, and if your firm is certified\nunder Section 8(a) of the Small Business Act. ***\nIs this service available under a federal supply schedule (GSA)? If yes, please provide\nthe contract number.\nAre you an authorized distributor/reseller? Must provide OEM authorization with SSN response.\nIs your (Contractor) Trade Agreement Certificate completed in SAM? Please provide evidence with a response.\nDoes the contractor possess the training and certification required to perform the startup and commissioning services with the OEM specifications and guidelines?\nContractors shall provide an estimated industry pricing for the product for market research and budgetary purposes.\nDoes the contractor have access to OEM parts for potential repairs?\nIs the contractor licensed in the State of Arkansas by the Elevator Safety Division at the Arkansas Department of Labor and Licensing?\n\nProvide descriptive literature demonstrating the ability to meet the SOW requirements/salient characteristics listed for the product being offered. Please provide a list of contracts for commercial, federal, state, and local governments. Listed contracts shall provide communication on the government requirement, illustrating the capability for comparison to the product meeting the specific requirements per the draft SOW.\n\nAll responses to this Sources Sought Notice should be emailed to carmyn.williams@va.gov. All responses are due by 10:00 AM on Tuesday, 10 February 2026.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25626Q0321","place_of_performance":{"zip":"72205","city":{"name":"Little Rock"},"state":{"name":"AR"},"street":"Central Arkansas Veterans Healthcare System (CAVHS)","country":{"code":"USA","name":"UNITED STATES"},"street2":"4300 West 7th Street"},"product_service_code":"H936"}],"due_at":"2026-02-10T16:00:00Z","due_date":"2026-02-10","closes_at":"2026-02-10T16:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C256","office_name":"256-NETWORK CONTRACT OFFICE 16 (36C256)","state":"AR","county":"05119","county_name":"Pulaski County","city":"0541000","city_name":"Little Rock","country":"USA","state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-15T02:32:28.018113Z","principal_notice_id":"81eda2f0cd45485aad1462d0a1597efd","description":{"text":"Sources Sought Notice (SSN)\n\nDepartment of Veterans Affairs, Veterans Health Administration, Network Contracting Office 16\n(NCO16)\n\nThis SSN is for market research and planning purposes only and shall not be considered an\nInvitation for Bid (IFB), Request for Task Execution Plan, Request for Quotation (RFQ), or a\nRequest for Proposal (RFP). Additionally, there is no obligation on the part of the Government to\nacquire any products or services described in this SSN. Your response to this SSN will be treated\nonly as information for the Government to consider. You will not be entitled to payment for\ndirect or indirect costs that you incur in responding to this SSN. This request does not constitute\na solicitation for proposals or the authority to enter negotiations to award a contract. No funds\nhave been authorized, appropriated, or received for this effort. Interested parties are responsible for adequately marking proprietary, restricted, or competition-sensitive information contained in their response. The Government does not intend to pay for the information submitted in response to this SSN.\n\nThe North American Industry Classification System (NAICS) for this requirement is 238290\nwith a size standard of $22.0 Million and Product Service Code (PSC) of H330.\n\nPlease note that this is a draft Statement of Work.\n\nDRAFT STATEMENT OF WORK (SOW)\nElevator Inspection\nElevator safety inspections for all traction and hydraulic elevators located at Central Arkansas Veterans Healthcare System (CAVHS) in Little Rock and North Little Rock, AR. The elevator maintenance contractor under contract with the CAVHS at the specific building location will be present and assist in the inspection and testing. The elevator maintenance contractor will provide the necessary expertise, manpower, test weights, gauges, dynamometers, etc., to perform the various inspections and tests required by code. The elevator inspector shall provide door pressure gauges, stopwatches, calipers, flashlights, and other small hand tools necessary to conduct inspections.\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n4300 West 7th Street, Little Rock, AR\nPassenger Cab Elevators\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n1\nP-1\n1\n4,000\n1984\n500\n8\nPower Doors\n2\nP-2\n1\n4,000\n1984\n500\n8\nPower Doors\n3\nP-3\n1\n4,000\n1984\n500\n8\nPower Doors\n4\nP-4\n1\n4,000\n1984\n500\n8\nPower Doors\n5\nP-5\n1\n4,000\n1984\n500\n8\nPower Doors\n6\nS-1\n1\n5,000\n1984\n500\n8\nPower Doors\n7\nS-2\n1\n5,000\n1984\n500\n8\nPower Doors\n8\nS-3\n1\n5,000\n1984\n500\n8\nPower Doors\n9\nS-4\n1\n5,000\n1984\n500\n8\nPower Doors\n10\nS-5\n1\n5,000\n1984\n500\n8\nPower Doors\n17\nVA-UAMS\n1\n4,500\n1984\n150\n1\nPower Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n4300 West 7th Street, Little Rock, AR\nCart Lift\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n11\nCartlift-1\n1\n300\n1984\n300\n8\nManual Doors\n12\nCartlift-2\n1\n300\n1984\n200\n8\nManual Doors\n13\nCartlift-3\n1\n300\n1984\n300\n8\nManual Doors\n14\nCartlift-4\n1\n300\n1984\n200\n8\nManual Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n4300 West 7th Street, Little Rock, AR\nDumbwaiter\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n15\nDW-1\n1\n300\n1984\n200\n8\nManual Doors\n16\nDW-2\n1\n300\n1984\n200\n8\nManual Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n4300 West 7th Street, Little Rock, AR\nPassenger Hydraulic Elevator\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n18\nMICU/1F\n1\n5,000\n2003\n100\n1\nPower Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n2200 Fort Roots Drive, North Little Rock, AR\nPassenger Cab Elevators\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n1\nBldg 58\n1\n3,500\n1965\n200\n3\nPower Doors\n2\nBldg 65\n1\n3,500\n1990\n200\n3\nPower Doors\n4\nBldg 66\n1\n3,500\n1968\n200\n3\nPower Doors\n6\nBldg 68\n1\n3,500\nUnknown\n200\n3\nPower Doors\n9\nBldg 111\n1\n3,500\n1966\n100\n3\nPower Doors\n11\nBldg 170\n1\n3,500\n1982\n350\n4\nPower Doors\n12\nBldg 170\n1\n4,000\n1982\n350\n4\nPower Doors\n13\nBldg 170\n1\n4,000\n1982\n350\n4\nPower Doors\n14\nBldg 170\n1\n4,000\n1982\n350\n4\nPower Doors\n15\nBldg 170\n1\n4,000\n1982\n350\n4\nPower Doors\n16\nBldg 170\n1\n5,000\n1982\n350\n4\nPower Doors\n17\nBldg 170\n1\n5,000\n1982\n350\n4\nPower Doors\n18\nBldg 170\n1\n5,000\n1982\n350\n4\nPower Doors\n19\nBldg 170\n1\n5,000\n1982\n350\n4\nPower Doors\n20\nBldg 170\n1\n5,000\n1982\n100\n4\nPower Doors\n21\nBldg 170\n1\n5,000\n1982\n350\n4\nPower Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n2200 Fort Roots Drive, North Little Rock, AR\nPassenger Hydraulic Elevators\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n3\nBldg 65\n1\n4,000\nUnknown\n150\n3\nPower Doors\n5\nBldg 66\n1\n4,000\nUnknown\n125\n3\nPower Doors\n8\nBldg 103\n1\n2,500\n1989\n125\n3\nPower Doors\n22\nBldg 170\n1\n5,000\n1982\n350\n4\nPower Doors\n24\nBldg 190\n1\n2,500\n1994\n125\n3\nPower Doors\n25\nBldg 190\n1\n2,500\n2011\n100\n3\nPower Doors\n27\nBldg 89\n1\n2,000\n2002\n100\n2\nPower Doors\n28\nBldg 193\n1\n3,000\n2014\n100\n2\nPower Doors\n29\nBldg 102\n1\n3,000\n2016\n100\n1\nPower Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n2200 Fort Roots Drive, North Little Rock, AR\nFreight Hydraulic Elevators\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n7\nBldg 76\n1\n2,500\n1980\n30\n1\nPower Doors\n10\nBldg 159\n1\n6,000\n1969\n50\n1\nPower Doors\n23\nBldg 182\n1\n10,000\n1982\n50\n1\nPower Doors\n26\nBldg 7\n1\n1,200\n1965\nUnknown\n3\nManual Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n2200 Fort Roots Drive, North Little Rock, AR\nWheelchair Lift\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n30\nBldg 33 HR\n1\n500\n1986\n3\nN/A\nManual Doors\n\nAll safety inspections shall be made in accordance with the latest revised edition of the American Society of Mechanical Engineers (ASME) Safety Code for Elevators and Escalators manual A17.1 Section X, A17.2, A17.3, A17.4, A17.5, A18.1 most recent edition the most current publication will be used at all times.\nWORK HOURS AND SCHEDULING ARRANGEMENTS\nAnnual safety test will be made during the contract period of performance on the proposal schedule for elevators/dumbwaiters at each CAVHS Medical Center for the base period and four (4) twelve (12) month renewal option periods. All elevators will require inspections, including but not limited to annual no-load, slow-speed safety tests of car safeties, governors, and buffers; Annual Firefighter s Service operation tests, annual standby power operation tests, battery pack lowering and car emergency lighting, pressure relief valve tests, and 5-year full load, full speed tests of car safeties.\nInspections shall be conducted in accordance with ASME A17.1 Safety Code for Elevators and Escalators and shall be based on the code edition in effect at the time when elevators were installed or modernized.\nAll inspections shall be coordinated with the CAVHS s Facilities Manager and/or Contracting Officers Representative (COR). The inspector shall also coordinate inspections and inspection time frames with the appropriate elevator maintenance contractor currently under contract with the VA. The COR at the medical center shall accompany the contractor as an observer during the entire time of each inspection. The VA Medical Center s COR shall be notified in writing no less than 15 calendar days prior to the scheduled inspection. Upon arrival to perform inspection, all service contract personnel must check in and out before providing services. Location for checking in and out during normal business hours will be indicated at the time of award. Service tickets must be signed and dated, indicating work complete or incomplete.\nThe inspector shall not proceed to the inspection site until the schedule has been agreed upon and coordinated with all parties involved in the scheduling process. All work shall be performed during regular working hours of the elevator trade, Monday through Friday, 7:00 AM to 3:30 PM, excluding government holidays. Inspection that may severely impact elevator service, or incapacitate a bank of elevators, shall be performed after normal working hours, i.e., firefighters' service, emergency control systems, etc. All work performed outside of regular working hours shall be approved in advance by the COR. Work will not be scheduled or performed on federal holidays. The Federal Holidays, which are observed by the federal government, are annotated below.\n\nNew Year s Day January 1\nMartin Luther King s Birthday Third Monday in January\nPresident s Day Third Monday in February\nMemorial Day Last Monday in May\nJuneteenth June 19\nIndependence Day July 4\nLabor Day First Monday in September\nColumbus Day Second Monday in October\nVeterans Day November 11\nThanksgiving Day Fourth Thursday in November\nChristmas Day December 25\n\nAny other day specifically declared to be a national holiday (per Federal Statute, Executive Order, or by the President s Proclamation).\nShould after-hour inspections be required, the Government will pay the difference between the straight time hourly labor rate and the overtime rate as established on the pricing schedule. Overtime work shall receive prior approval from the COR. Overtime hours will be computed between the hours of 3:29 PM and 6:59 AM, Monday through Friday. Weekend work will be paid at the full overtime rate as established on the proposal Schedule. The full overtime rate will apply for work performed during the following National holidays: Labor Day, Christmas, New Year's, Thanksgiving, Memorial Day, and Independence Day. Inspections performed during other Government holidays will be paid at the straight-time hourly rate.\nInspections that require a return visit to the work site due to unforeseen problems that cause a delay in the inspection process shall be addressed to the Contracting Officer and COR on a case-by-case basis. The contractor may be reimbursed for additional time spent on the job site; however, the cost for additional man-hours shall be negotiated with the Contracting Officer before starting work. Reimbursement shall be based on the price per man-hour for inspection time as reflected in the price proposal schedule.\n\nSCOPE\nThe vendor shall provide all inspection, engineering, management, supervision, manpower, materials, supplies, equipment, travel and all costs to and from, to plan, schedule, coordinate and assure effective performance of all inspection services for the elevators and other vertical transport equipment. Any changes to this contract shall be reflected in a written modification to this contract, signed by the contractor and the Contracting Officer.\nThe contractor in question must be certified by the Elevator Safety Division at Arkansas Department of Labor and Licensing. The contractor shall furnish all qualified/certified personnel, materials, equipment, and services to include lodging, travel, and meals necessary to perform the following scope of work. The contractor will witness annual safety tests and five-year load tests on electric and three-year pressure tests on hydraulic elevators and dumbwaiters. These specifications cover the annual inspections of electric or hydraulic elevators and dumbwaiters, the annual tests of governor and safety devices, on all facility elevators and dumbwaiters during the period indicated in the proposal schedule for the base year period and a total of four (4) renewal option periods. Inspections and documentation shall be in accordance with the American National Standard Safety Code (ANSI), NFPA 70 National Electric Code and the American Society of Mechanical Engineers (ASME) Safety Code for Elevators and Escalators manual A17.1 Section X, A17.2, A17.3, A17.4, A17.5, A18.1 most recent edition the most current publication will be used at all times.\nAt a minimum, the inspector shall maintain a library of the following publications applicable to the type of inspection being conducted:\nASME A17.1, Safety Code for Elevators and Escalators\nASME A17.5, Elevator and Escalator Electrical Equipment.\nASME A17.2, Inspector s Guide for Inspection of Elevators, Escalators and Moving Walks.\nASME A17.3, Safety Code for Existing Elevators and Escalators.\nA17.1 Handbook Safety Code for Elevators and Escalators.\nNFPA 70 (National Electric Code)\nApplicable IBC and NFPA code books.\nASME A18.1, Safety Standard for Platform Lifts and Stairway Chairlifts.\nIt is the responsibility of the inspector to determine if the equipment is in a safe operating condition, that it has not been altered except in conformity to the applicable codes or regulations, and that each elevator will perform in accordance with all applicable inspection requirements.\nANNUAL SAFETY INSPECTION\nAn annual safety inspection will be performed on elevators/dumbwaiters. Safeties shall be subjected to an annual running test per the recommended guidelines as indicated by ANSI/ASME A17.1.\nThe slowest operating speed, at no load test required for annual test as indicated in the Safety test instructions on VISN 15 Report of Test of Elevator Governor and Safety Devices (see Attachment A)\nThe elevator maintenance company is required to furnish the tools and labor to perform the annual no-load tests. The inspection contractor will witness and certify the inspection.\nPhase I Lobby Key Switch (maintenance and fire service personnel system verification checks) recall by use of the key switch, and a minimum of one-floor operation on Phase II Service check should be accomplished during the annual safety check.\nInspections are to be made in accordance with the American National Standard Safety Code for Elevators and Escalators manual, ANSI/ASME A17.1 Section X, latest edition. Elevators are to be run at a slow speed.\nFIVE (5) YEAR SAFETY TEST/THREE (3) YEAR PRESSURE\nA five-year safety test will be performed on the elevators and dumbwaiters listed. Safeties shall be subjected to the ASME testing standards for car and counterweights, safeties, governors, and oil buffers. All work is to be performed in accordance with Rule 1002.3, 5-year inspection test requirements, ASME A17.1, latest edition.\nAt a minimum, elevators/dumbwaiters at all stations should have the following inspection points covered in accordance with ASME A17.1 Section X, plus A17.2 for the full load tests:\nTest the car safety devices and overspeed governor with 100% contract load at speed.\nTest the car brake and emergency power operation with 125% contract load.\nTesting and calibration of the overspeed governor jaw and overspeed switch tripping speeds.\nAttach metal test tags. Seal and tag all safety devices and oil buffers.\nTest the oil buffers in the following manner:\nrunning onto the car buffers with contract load at inspection speed.\nrunning onto the counterweight buffers with the car empty running at inspection speed in the up direction.\nTest terminal, normal and emergency limits.\nTest leveling zone and leveling speeds with contract load.\nTest the door pressure and kinetic energy.\nTest the governor pull-through tension.\nRecord the following: capacity, speed empty up and down, speed loaded up and down, safety jaw tripping speed, overspeed governor tripping speed, safety slide on the rails, governor pull through, governor plate speed, car level after test, buffer return time, complete firefighters service check as applicable, and safety rope pull out as applicable.\nPerform all inspections and tests in strict accordance with ANSI/ASME A17.1, Section X plus A 17.2.\nList code violations observed during tests.\nA five-year load test is required based on DIV II - 210.2.\nTesting requires 50 lb. test weights.\nThe elevator maintenance company is required to furnish weights, tools, and labor to perform the five-year full load test. The elevator inspection contractor will witness and certify the inspection.\nThe contractor will perform a three-year pressure test on all hydraulic elevators IAW ASME A17.1 latest edition.\n\nWORKMANSHIP\nAll inspections shall be conducted professionally and thoroughly. All inspections, workmanship, or equipment shall be subject to re-inspection, examination, and test by Government inspectors at all times during the course of the work and at all places where such work is being conducted. The Government shall have the right to reject defective inspections or reports. Rejected inspections or reports shall be satisfactorily corrected and/or replaced without additional expense to the Government.\nCERTIFICATE OF INSPECTION:\nThe inspector shall, upon completion of inspection, ensure that the inspector s signature and date are entered on the Government-furnished Certificate of Elevator Inspection. Certificates for elevators are to be posted on file in the Facilities Management Office.\n\nShould the inspector, using professional judgment, believe the elevator to be unsafe at the time of inspection, he or she may, at his or her discretion, shut the elevator down until corrective action is taken. Elevator service shall not be restored until the deficiencies have been corrected and the elevator is re-inspected and found suitable for use.\n\nDELIVERABLES (INSPECTION AND TEST REPORTS)\nInspector shall use the ASME Elevator Inspection Checklist as a guide for inspection purposes. 5-year full load test forms shall be provided by the inspector and approved by the COR. A separate test form and checklist shall be provided for each elevator inspected. When inspections are completed, the inspector shall compile a comprehensive narrative report with findings and recommendations, including deficiencies and recommended corrective action. Code-specific items should also be noted on the report with reference to code rules. The report shall be done professionally, typewritten, signed, and dated by the inspector. The contractor shall have the capability to distribute reports electronically via email.\nReports and checklists shall be submitted within ten (10) calendar days after completion of an inspection. Safety deficiencies or any items that require immediate attention shall be reported right away to the Facilities Manager at the Medical Center or COR for corrective action.\nThe contractor shall complete a full report upon completion of the inspection. For all items on such forms that are not applicable, the notation \"NA\" (not applicable) shall be made. On the reverse side of such forms, the contractor shall clearly indicate any adjustments, repairs, or replacements necessary to correct troubles encountered, shall definitively justify such recommendations, and shall furnish specifications sufficient to enable VA to purchase the materials required for such purposes (and cost estimate if available). Also, on the reverse side of the forms, the contractor shall advise whether the elevator parts have been kept clean and lubricated where necessary.\n\nSAFETY REQUIREMENTS\nIn the performance of this contract, the Contractor shall take such safety precautions as the Contracting Officer or his designee may determine to be reasonably necessary to protect the lives and health of occupants of the building. The Contracting Officer or COR will notify the Contractor of any noncompliance with the foregoing provisions and the action to be taken.\n\nThe Contractor shall, after receipt of such notice, immediately correct the conditions to which attention has been directed. Such notice, when served on the Contractor or his representative at the site of work, shall be deemed sufficient for the purpose aforesaid. If the Contractor fails or refuses to comply promptly, the Contacting Officer may issue an order, stopping all or any part of the work, and hold the Contractor in default in accordance with the Default clause in this contract.\n\nQUALITY PERFORMANCE STANDARD\nElevator inspectors and consultants shall meet the ASME QEI-1 standard in addition to being certified by the Elevator Safety Division at the Arkansas Department of Labor and Licensing. Inspectors and/or consultants shall also have a minimum of five (5) years of practical field experience in the vertical transportation industry at the journeyman level. A professional engineering license is considered journeyman level, provided the engineer has five (5) years experience in the elevator field. All offers must include documentation and proof of the above certifications and qualifications.\nPursuant to ANSI/ASME A17.1 Section 1000, ASME A17.2, ASME A17.3 the Contractor must provide proof of QE-1 certification. A copy of this certificate must be provided with the proposal. A copy of the Inspector s QEI credentials shall be current and provided to the COR. Credentials shall be kept on file in the Facilities Elevator Inspection File at each Facilities Management Office location.\nInspectors and/or consultants shall be able to communicate effectively both orally and in writing and possess the skills necessary to prepare professionally written comprehensive narrative reports, specifications, and cost estimates.\nContractor shall submit a quality control plan within thirty (30) calendar days after notice to proceed, consisting of a plan as to what standard their company holds their inspectors to, and the frequency at which their work is checked.\n\nINSPECTION AND TESTING SERVICES\nElevator Safety Inspections\nThe independent VA contract inspector shall witness the annual safety test and five (5) year load tests on electric or hydraulic elevators and dumbwaiters in accordance with the requirements of the latest edition of /ASMI QEI-1, Standard for the Qualification of Elevator Inspectors. The contractor shall provide personnel who are familiar with the equipment to perform tests and assist the inspector.\n\nThe contractor shall schedule and have performed the periodic inspections and tests of all elevators at the recommended intervals found in the effective edition of ANSI/ASME A17. The maintenance contractor must coordinate the performance of the safety inspections with the independent VA.\n\nThe contractor shall furnish a copy of the inspection schedule to the COR (this list shall be estimated for proposal submission and finalized before award of the contract. This schedule shall clearly indicate the edition of ANSI/ASME A17. The COR will be advised of any changes to the schedule and notified fifteen (15) working days in advance of the inspection date to allow the COR to observe the inspection. The required annual inspection of the emergency signaling device (alarm) and the means of two-way conversation will be recorded on an approved form. Copies of this form will be provided to the contractor by the COR.\n\nThe contractor shall provide a qualified employee to accompany the inspector during the inspection.\n\nThe Independent VA Contract Inspector shall furnish a written report of each inspection to the COR and to the maintenance contractor. The report shall be submitted on the following checklists from the American Society of Mechanical Engineers (ASME): Checklist for Inspection of Electric Elevators, Checklist for Inspection of Hydraulic Elevators, as appropriate. The maintenance contractor shall be responsible for the correction of all listed deficiencies within the scope of the contract by the date specified by the COR. Any deficiencies marked \"emergency\" must be corrected immediately. When all listed deficiencies have been corrected the contractor shall sign and date the inspection report and return it to the COR.\nThe contractor shall be responsible for obtaining the signed form from the independent VA contractor elevator inspector. Copies of the form will be provided to the Contracting Officer and COR.\n\nThe following information is requested in response to this SSN:\nGeneral Company Information:\nName of Company:\nAddress:\nPoint of Contact:\nPhone Number:\nEmail Address:\nCompany Website (if available):\nSAM Unique Entity Identifier Number:\nCommercial & Government Entity (CAGE) Number:\nBusiness Type (Socio-economic status as it relates to 238290). Please ensure the System\nfor Award Management (SAM sam.gov) indicates this NAICS code if you are\ninterested in the requirement. Please put a check mark or X next to the type of business\nyou are below:\nLarge\n8(a)\nHUBZone\nSmall Business\nSmall Disadvantaged Business\nWoman-Owned Small Business\nService-Disabled Veteran-Owned Small Business\nVeteran-Owned Small Business\n***Note: All Veteran-Owned Businesses must be registered in SBA Veteran Small\nBusiness Certification at Veteran Small Business Certification (sba.gov) to be\nconsidered a Veteran Owned Business. Socioeconomic status (whether Service Disabled\nVeteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VSOB),\nHUBZone, 8(a), Woman Owned, Small Disadvantaged, etc.).\n\nIf small, does your firm qualify as a small, emerging business, or small disadvantaged\nbusiness? For all small businesses, including SDVOSB and VOSB, at least fifty (50)\npercent of the cost of contract performance incurred for personnel shall be expended for\nemployees of the concern.\n\nIf disadvantaged, specify under which disadvantaged group, and if your firm is certified\nunder Section 8(a) of the Small Business Act. ***\nIs this service available under a federal supply schedule (GSA)? If yes, please provide\nthe contract number.\nAre you an authorized distributor/reseller? Must provide OEM authorization with SSN response.\nIs your (Contractor) Trade Agreement Certificate completed in SAM? Please provide evidence with a response.\nDoes the contractor possess the training and certification required to perform the startup and commissioning services with the OEM specifications and guidelines?\nContractors shall provide an estimated industry pricing for the product for market research and budgetary purposes.\nDoes the contractor have access to OEM parts for potential repairs?\nIs the contractor licensed in the State of Arkansas by the Elevator Safety Division at the Arkansas Department of Labor and Licensing?\n\nProvide descriptive literature demonstrating the ability to meet the SOW requirements/salient characteristics listed for the product being offered. Please provide a list of contracts for commercial, federal, state, and local governments. Listed contracts shall provide communication on the government requirement, illustrating the capability for comparison to the product meeting the specific requirements per the draft SOW.\n\nAll responses to this Sources Sought Notice should be emailed to carmyn.williams@va.gov. All responses are due by 10:00 AM on Tuesday, 10 February 2026.","html":"Sources Sought Notice (SSN)\n\nDepartment of Veterans Affairs, Veterans Health Administration, Network Contracting Office 16\n(NCO16)\n\nThis SSN is for market research and planning purposes only and shall not be considered an\nInvitation for Bid (IFB), Request for Task Execution Plan, Request for Quotation (RFQ), or a\nRequest for Proposal (RFP). Additionally, there is no obligation on the part of the Government to\nacquire any products or services described in this SSN. Your response to this SSN will be treated\nonly as information for the Government to consider. You will not be entitled to payment for\ndirect or indirect costs that you incur in responding to this SSN. This request does not constitute\na solicitation for proposals or the authority to enter negotiations to award a contract. No funds\nhave been authorized, appropriated, or received for this effort. Interested parties are responsible for adequately marking proprietary, restricted, or competition-sensitive information contained in their response. The Government does not intend to pay for the information submitted in response to this SSN.\n\nThe North American Industry Classification System (NAICS) for this requirement is 238290\nwith a size standard of $22.0 Million and Product Service Code (PSC) of H330.\n\nPlease note that this is a draft Statement of Work.\n\nDRAFT STATEMENT OF WORK (SOW)\nElevator Inspection\nElevator safety inspections for all traction and hydraulic elevators located at Central Arkansas Veterans Healthcare System (CAVHS) in Little Rock and North Little Rock, AR.  The elevator maintenance contractor under contract with the CAVHS at the specific building location will be present and assist in the inspection and testing. The elevator maintenance contractor will provide the necessary expertise, manpower, test weights, gauges, dynamometers, etc., to perform the various inspections and tests required by code. The elevator inspector shall provide door pressure gauges, stopwatches, calipers, flashlights, and other small hand tools necessary to conduct inspections.\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n4300 West 7th Street, Little Rock, AR\nPassenger Cab Elevators\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n1\nP-1\n1\n4,000\n1984\n500\n8\nPower Doors\n2\nP-2\n1\n4,000\n1984\n500\n8\nPower Doors\n3\nP-3\n1\n4,000\n1984\n500\n8\nPower Doors\n4\nP-4\n1\n4,000\n1984\n500\n8\nPower Doors\n5\nP-5\n1\n4,000\n1984\n500\n8\nPower Doors\n6\nS-1\n1\n5,000\n1984\n500\n8\nPower Doors\n7\nS-2\n1\n5,000\n1984\n500\n8\nPower Doors\n8\nS-3\n1\n5,000\n1984\n500\n8\nPower Doors\n9\nS-4\n1\n5,000\n1984\n500\n8\nPower Doors\n10\nS-5\n1\n5,000\n1984\n500\n8\nPower Doors\n17\nVA-UAMS\n1\n4,500\n1984\n150\n1\nPower Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n4300 West 7th Street, Little Rock, AR\nCart Lift\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n11\nCartlift-1\n1\n300\n1984\n300\n8\nManual Doors\n12\nCartlift-2\n1\n300\n1984\n200\n8\nManual Doors\n13\nCartlift-3\n1\n300\n1984\n300\n8\nManual Doors\n14\nCartlift-4\n1\n300\n1984\n200\n8\nManual Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n4300 West 7th Street, Little Rock, AR\nDumbwaiter\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n15\nDW-1\n1\n300\n1984\n200\n8\nManual Doors\n16\nDW-2\n1\n300\n1984\n200\n8\nManual Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n4300 West 7th Street, Little Rock, AR\nPassenger Hydraulic Elevator\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n18\nMICU/1F\n1\n5,000\n2003\n100\n1\nPower Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n2200 Fort Roots Drive, North Little Rock, AR\nPassenger Cab Elevators\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n1\nBldg 58\n1\n3,500\n1965\n200\n3\nPower Doors\n2\nBldg 65\n1\n3,500\n1990\n200\n3\nPower Doors\n4\nBldg 66\n1\n3,500\n1968\n200\n3\nPower Doors\n6\nBldg 68\n1\n3,500\nUnknown\n200\n3\nPower Doors\n9\nBldg 111\n1\n3,500\n1966\n100\n3\nPower Doors\n11\nBldg 170\n1\n3,500\n1982\n350\n4\nPower Doors\n12\nBldg 170\n1\n4,000\n1982\n350\n4\nPower Doors\n13\nBldg 170\n1\n4,000\n1982\n350\n4\nPower Doors\n14\nBldg 170\n1\n4,000\n1982\n350\n4\nPower Doors\n15\nBldg 170\n1\n4,000\n1982\n350\n4\nPower Doors\n16\nBldg 170\n1\n5,000\n1982\n350\n4\nPower Doors\n17\nBldg 170\n1\n5,000\n1982\n350\n4\nPower Doors\n18\nBldg 170\n1\n5,000\n1982\n350\n4\nPower Doors\n19\nBldg 170\n1\n5,000\n1982\n350\n4\nPower Doors\n20\nBldg 170\n1\n5,000\n1982\n100\n4\nPower Doors\n21\nBldg 170\n1\n5,000\n1982\n350\n4\nPower Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n2200 Fort Roots Drive, North Little Rock, AR\nPassenger Hydraulic Elevators\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n3\nBldg 65\n1\n4,000\nUnknown\n150\n3\nPower Doors\n5\nBldg 66\n1\n4,000\nUnknown\n125\n3\nPower Doors\n8\nBldg 103\n1\n2,500\n1989\n125\n3\nPower Doors\n22\nBldg 170\n1\n5,000\n1982\n350\n4\nPower Doors\n24\nBldg 190\n1\n2,500\n1994\n125\n3\nPower Doors\n25\nBldg 190\n1\n2,500\n2011\n100\n3\nPower Doors\n27\nBldg 89\n1\n2,000\n2002\n100\n2\nPower Doors\n28\nBldg 193\n1\n3,000\n2014\n100\n2\nPower Doors\n29\nBldg 102\n1\n3,000\n2016\n100\n1\nPower Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n2200 Fort Roots Drive, North Little Rock, AR\nFreight Hydraulic Elevators\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n7\nBldg 76\n1\n2,500\n1980\n30\n1\nPower Doors\n10\nBldg 159\n1\n6,000\n1969\n50\n1\nPower Doors\n23\nBldg 182\n1\n10,000\n1982\n50\n1\nPower Doors\n26\nBldg 7\n1\n1,200\n1965\nUnknown\n3\nManual Doors\n\nCentral Arkansas Veterans Healthcare System (CAVHS)\n2200 Fort Roots Drive, North Little Rock, AR\nWheelchair Lift\nSys ID\nLocation\n# of Doors\nCapacity (lbs)\nYear Installed\nSpeed (FPM)\n# of Floors\nType\n30\nBldg 33 HR\n1\n500\n1986\n3\nN/A\nManual Doors\n\nAll safety inspections shall be made in accordance with the latest revised edition of the American Society of Mechanical Engineers (ASME) Safety Code for Elevators and Escalators manual A17.1 Section X, A17.2, A17.3, A17.4, A17.5, A18.1 most recent edition the most current publication will be used at all times.\nWORK HOURS AND SCHEDULING ARRANGEMENTS\nAnnual safety test will be made during the contract period of performance on the proposal schedule for elevators/dumbwaiters at each CAVHS Medical Center for the base period and four (4) twelve (12) month renewal option periods. All elevators will require inspections, including but not limited to annual no-load, slow-speed safety tests of car safeties, governors, and buffers; Annual Firefighter s Service operation tests, annual standby power operation tests, battery pack lowering and car emergency lighting, pressure relief valve tests, and 5-year full load, full speed tests of car safeties.\nInspections shall be conducted in accordance with ASME A17.1 Safety Code for Elevators and Escalators and shall be based on the code edition in effect at the time when elevators were installed or modernized.\nAll inspections shall be coordinated with the CAVHS s Facilities Manager and/or Contracting Officers Representative (COR). The inspector shall also coordinate inspections and inspection time frames with the appropriate elevator maintenance contractor currently under contract with the VA. The COR at the medical center shall accompany the contractor as an observer during the entire time of each inspection. The VA Medical Center s COR shall be notified in writing no less than 15 calendar days prior to the scheduled inspection. Upon arrival to perform inspection, all service contract personnel must check in and out before providing services. Location for checking in and out during normal business hours will be indicated at the time of award. Service tickets must be signed and dated, indicating work complete or incomplete.\nThe inspector shall not proceed to the inspection site until the schedule has been agreed upon and coordinated with all parties involved in the scheduling process. All work shall be performed during regular working hours of the elevator trade, Monday through Friday, 7:00 AM to 3:30 PM, excluding government holidays. Inspection that may severely impact elevator service, or incapacitate a bank of elevators, shall be performed after normal working hours, i.e., firefighters' service, emergency control systems, etc. All work performed outside of regular working hours shall be approved in advance by the COR.  Work will not be scheduled or performed on federal holidays. The Federal Holidays, which are observed by the federal government, are annotated below.\n \nNew Year s Day     January 1\nMartin Luther King s Birthday   Third Monday in January\nPresident s Day     Third Monday in February\nMemorial Day     Last Monday in May\nJuneteenth      June 19\nIndependence Day     July 4\nLabor Day      First Monday in September\nColumbus Day     Second Monday in October\nVeterans Day     November 11\nThanksgiving Day     Fourth Thursday in November\nChristmas Day     December 25\n\nAny other day specifically declared to be a national holiday (per Federal Statute, Executive Order, or by the President s Proclamation). \nShould after-hour inspections be required, the Government will pay the difference between the straight time hourly labor rate and the overtime rate as established on the pricing schedule. Overtime work shall receive prior approval from the COR. Overtime hours will be computed between the hours of 3:29 PM and 6:59 AM, Monday through Friday. Weekend work will be paid at the full overtime rate as established on the proposal Schedule. The full overtime rate will apply for work performed during the following National holidays: Labor Day, Christmas, New Year's, Thanksgiving, Memorial Day, and Independence Day. Inspections performed during other Government holidays will be paid at the straight-time hourly rate.\nInspections that require a return visit to the work site due to unforeseen problems that cause a delay in the inspection process shall be addressed to the Contracting Officer and COR on a case-by-case basis. The contractor may be reimbursed for additional time spent on the job site; however, the cost for additional man-hours shall be negotiated with the Contracting Officer before starting work. Reimbursement shall be based on the price per man-hour for inspection time as reflected in the price proposal schedule.\n\nSCOPE\nThe vendor shall provide all inspection, engineering, management, supervision, manpower, materials, supplies, equipment, travel and all costs to and from, to plan, schedule, coordinate and assure effective performance of all inspection services for the elevators and other vertical transport equipment.  Any changes to this contract shall be reflected in a written modification to this contract, signed by the contractor and the Contracting Officer.\nThe contractor in question must be certified by the Elevator Safety Division at Arkansas Department of Labor and Licensing. The contractor shall furnish all qualified/certified personnel, materials, equipment, and services to include lodging, travel, and meals necessary to perform the following scope of work.   The contractor will witness annual safety tests and five-year load tests on electric and three-year pressure tests on hydraulic elevators and dumbwaiters. These specifications cover the annual inspections of electric or hydraulic elevators and dumbwaiters, the annual tests of governor and safety devices, on all facility elevators and dumbwaiters during the period indicated in the proposal schedule for the base year period and a total of four (4) renewal option periods. Inspections and documentation shall be in accordance with the American National Standard Safety Code (ANSI), NFPA 70 National Electric Code and the American Society of Mechanical Engineers (ASME) Safety Code for Elevators and Escalators manual A17.1 Section X, A17.2, A17.3, A17.4, A17.5, A18.1 most recent edition the most current publication will be used at all times.\nAt a minimum, the inspector shall maintain a library of the following publications applicable to the type of inspection being conducted:\nASME A17.1, Safety Code for Elevators and Escalators\nASME A17.5, Elevator and Escalator Electrical Equipment.\nASME A17.2, Inspector s Guide for Inspection of Elevators, Escalators and Moving Walks. \nASME A17.3, Safety Code for Existing Elevators and Escalators.\nA17.1 Handbook   Safety Code for Elevators and Escalators.\nNFPA 70 (National Electric Code)\nApplicable IBC and NFPA code books.\nASME A18.1, Safety Standard for Platform Lifts and Stairway Chairlifts.\nIt is the responsibility of the inspector to determine if the equipment is in a safe operating condition, that it has not been altered except in conformity to the applicable codes or regulations, and that each elevator will perform in accordance with all applicable inspection requirements.\nANNUAL SAFETY INSPECTION\nAn annual safety inspection will be performed on elevators/dumbwaiters.  Safeties shall be subjected to an annual running test per the recommended guidelines as indicated by ANSI/ASME A17.1.\nThe slowest operating speed, at no load test required for annual test as indicated in the Safety test instructions on VISN 15 Report of Test of Elevator Governor and Safety Devices (see Attachment A)\nThe elevator maintenance company is required to furnish the tools and labor to perform the annual no-load tests. The inspection contractor will witness and certify the inspection.\nPhase I Lobby Key Switch (maintenance and fire service personnel system verification checks) recall by use of the key switch, and a minimum of one-floor operation on Phase II Service check should be accomplished during the annual safety check.\nInspections are to be made in accordance with the American National Standard Safety Code for Elevators and Escalators manual, ANSI/ASME A17.1 Section X, latest edition. Elevators are to be run at a slow speed.\nFIVE (5) YEAR SAFETY TEST/THREE (3) YEAR PRESSURE\nA five-year safety test will be performed on the elevators and dumbwaiters listed. Safeties shall be subjected to the ASME testing standards for car and counterweights, safeties, governors, and oil buffers. All work is to be performed in accordance with Rule 1002.3, 5-year inspection test requirements, ASME A17.1, latest edition.\nAt a minimum, elevators/dumbwaiters at all stations should have the following inspection points covered in accordance with ASME A17.1 Section X, plus A17.2 for the full load tests:\nTest the car safety devices and overspeed governor with 100% contract load at speed.\nTest the car brake and emergency power operation with 125% contract load.\nTesting and calibration of the overspeed governor jaw and overspeed switch tripping speeds.\nAttach metal test tags. Seal and tag all safety devices and oil buffers.\nTest the oil buffers in the following manner:\nrunning onto the car buffers with contract load at inspection speed.\nrunning onto the counterweight buffers with the car empty running at inspection speed in the up direction.\nTest terminal, normal and emergency limits.\nTest leveling zone and leveling speeds with contract load.\nTest the door pressure and kinetic energy.\nTest the governor pull-through tension.\nRecord the following: capacity, speed empty up and down, speed loaded up and down, safety jaw tripping speed, overspeed governor tripping speed, safety slide on the rails, governor pull through, governor plate speed, car level after test, buffer return time, complete firefighters service check as applicable, and safety rope pull out as applicable.\nPerform all inspections and tests in strict accordance with ANSI/ASME A17.1, Section X plus A 17.2.\nList code violations observed during tests.\nA five-year load test is required based on DIV II - 210.2.\nTesting requires 50 lb. test weights. \nThe elevator maintenance company is required to furnish weights, tools, and labor to perform the five-year full load test. The elevator inspection contractor will witness and certify the inspection.\nThe contractor will perform a three-year pressure test on all hydraulic elevators IAW ASME A17.1 latest edition.\n\nWORKMANSHIP\nAll inspections shall be conducted professionally and thoroughly.  All inspections, workmanship, or equipment shall be subject to re-inspection, examination, and test by Government inspectors at all times during the course of the work and at all places where such work is being conducted.  The Government shall have the right to reject defective inspections or reports.  Rejected inspections or reports shall be satisfactorily corrected and/or replaced without additional expense to the Government.\nCERTIFICATE OF INSPECTION:\nThe inspector shall, upon completion of inspection, ensure that the inspector s signature and date are entered on the Government-furnished Certificate of Elevator Inspection. Certificates for elevators are to be posted on file in the Facilities Management Office.\n\nShould the inspector, using professional judgment, believe the elevator to be unsafe at the time of inspection, he or she may, at his or her discretion, shut the elevator down until corrective action is taken. Elevator service shall not be restored until the deficiencies have been corrected and the elevator is re-inspected and found suitable for use.\n\nDELIVERABLES (INSPECTION AND TEST REPORTS)\nInspector shall use the ASME Elevator Inspection Checklist as a guide for inspection purposes. 5-year full load test forms shall be provided by the inspector and approved by the COR. A separate test form and checklist shall be provided for each elevator inspected. When inspections are completed, the inspector shall compile a comprehensive narrative report with findings and recommendations, including deficiencies and recommended corrective action. Code-specific items should also be noted on the report with reference to code rules. The report shall be done professionally, typewritten, signed, and dated by the inspector. The contractor shall have the capability to distribute reports electronically via email.\nReports and checklists shall be submitted within ten (10) calendar days after completion of an inspection. Safety deficiencies or any items that require immediate attention shall be reported right away to the Facilities Manager at the Medical Center or COR for corrective action.\nThe contractor shall complete a full report upon completion of the inspection. For all items on such forms that are not applicable, the notation \"NA\" (not applicable) shall be made. On the reverse side of such forms, the contractor shall clearly indicate any adjustments, repairs, or replacements necessary to correct troubles encountered, shall definitively justify such recommendations, and shall furnish specifications sufficient to enable VA to purchase the materials required for such purposes (and cost estimate if available). Also, on the reverse side of the forms, the contractor shall advise whether the elevator parts have been kept clean and lubricated where necessary.\n\nSAFETY REQUIREMENTS\nIn the performance of this contract, the Contractor shall take such safety precautions as the Contracting Officer or his designee may determine to be reasonably necessary to protect the lives and health of occupants of the building. The Contracting Officer or COR will notify the Contractor of any noncompliance with the foregoing provisions and the action to be taken.\n\nThe Contractor shall, after receipt of such notice, immediately correct the conditions to which attention has been directed. Such notice, when served on the Contractor or his representative at the site of work, shall be deemed sufficient for the purpose aforesaid. If the Contractor fails or refuses to comply promptly, the Contacting Officer may issue an order, stopping all or any part of the work, and hold the Contractor in default in accordance with the Default clause in this contract.\n\nQUALITY PERFORMANCE STANDARD\nElevator inspectors and consultants shall meet the ASME QEI-1 standard in addition to being certified by the Elevator Safety Division at the Arkansas Department of Labor and Licensing. Inspectors and/or consultants shall also have a minimum of five (5) years of practical field experience in the vertical transportation industry at the journeyman level. A professional engineering license is considered journeyman level, provided the engineer has five (5) years  experience in the elevator field. All offers must include documentation and proof of the above certifications and qualifications.\nPursuant to ANSI/ASME A17.1 Section 1000, ASME A17.2, ASME A17.3 the Contractor must provide proof of QE-1 certification. A copy of this certificate must be provided with the proposal. A copy of the Inspector s QEI credentials shall be current and provided to the COR. Credentials shall be kept on file in the Facilities Elevator Inspection File at each Facilities Management Office location.\nInspectors and/or consultants shall be able to communicate effectively both orally and in writing and possess the skills necessary to prepare professionally written comprehensive narrative reports, specifications, and cost estimates.\nContractor shall submit a quality control plan within thirty (30) calendar days after notice to proceed, consisting of a plan as to what standard their company holds their inspectors to, and the frequency at which their work is checked.\n\nINSPECTION AND TESTING SERVICES\nElevator Safety Inspections\nThe independent VA contract inspector shall witness the annual safety test and five (5) year load tests on electric or hydraulic elevators and dumbwaiters in accordance with the requirements of the latest edition of /ASMI QEI-1, Standard for the Qualification of Elevator Inspectors. The contractor shall provide personnel who are familiar with the equipment to perform tests and assist the inspector. \n\nThe contractor shall schedule and have performed the periodic inspections and tests of all elevators at the recommended intervals found in the effective edition of ANSI/ASME A17. The maintenance contractor must coordinate the performance of the safety inspections with the independent VA.\n\nThe contractor shall furnish a copy of the inspection schedule to the COR (this list shall be estimated for proposal submission and finalized before award of the contract. This schedule shall clearly indicate the edition of ANSI/ASME A17. The COR will be advised of any changes to the schedule and notified fifteen (15) working days in advance of the inspection date to allow the COR to observe the inspection. The required annual inspection of the emergency signaling device (alarm) and the means of two-way conversation will be recorded on an approved form. Copies of this form will be provided to the contractor by the COR.\n\nThe contractor shall provide a qualified employee to accompany the inspector during the inspection.\n\nThe Independent VA Contract Inspector shall furnish a written report of each inspection to the COR and to the maintenance contractor. The report shall be submitted on the following checklists from the American Society of Mechanical Engineers (ASME): Checklist for Inspection of Electric Elevators, Checklist for Inspection of Hydraulic Elevators, as appropriate. The maintenance contractor shall be responsible for the correction of all listed deficiencies within the scope of the contract by the date specified by the COR. Any deficiencies marked \"emergency\" must be corrected immediately. When all listed deficiencies have been corrected the contractor shall sign and date the inspection report and return it to the COR.\nThe contractor shall be responsible for obtaining the signed form from the independent VA contractor elevator inspector.  Copies of the form will be provided to the Contracting Officer and COR.\n\nThe following information is requested in response to this SSN:\nGeneral Company Information:\nName of Company:\nAddress:\nPoint of Contact:\nPhone Number:\nEmail Address:\nCompany Website (if available):\nSAM Unique Entity Identifier Number:\nCommercial & Government Entity (CAGE) Number:\nBusiness Type (Socio-economic status as it relates to 238290). Please ensure the System\nfor Award Management (SAM   sam.gov) indicates this NAICS code if you are\ninterested in the requirement. Please put a check mark or X next to the type of business\nyou are below:\nLarge\n8(a)\nHUBZone\nSmall Business\nSmall Disadvantaged Business\nWoman-Owned Small Business\nService-Disabled Veteran-Owned Small Business\nVeteran-Owned Small Business\n***Note: All Veteran-Owned Businesses must be registered in SBA Veteran Small\nBusiness Certification at Veteran Small Business Certification (sba.gov) to be\nconsidered a Veteran Owned Business. Socioeconomic status (whether Service Disabled\nVeteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VSOB),\nHUBZone, 8(a), Woman Owned, Small Disadvantaged, etc.).\n\nIf small, does your firm qualify as a small, emerging business, or small disadvantaged\nbusiness? For all small businesses, including SDVOSB and VOSB, at least fifty (50)\npercent of the cost of contract performance incurred for personnel shall be expended for\nemployees of the concern.\n\nIf disadvantaged, specify under which disadvantaged group, and if your firm is certified\nunder Section 8(a) of the Small Business Act. ***\nIs this service available under a federal supply schedule (GSA)? If yes, please provide\nthe contract number.\nAre you an authorized distributor/reseller?  Must provide OEM authorization with SSN response.\nIs your (Contractor) Trade Agreement Certificate completed in SAM?  Please provide evidence with a response.\nDoes the contractor possess the training and certification required to perform the startup and commissioning services with the OEM specifications and guidelines?\nContractors shall provide an estimated industry pricing for the product for market research and budgetary purposes.\nDoes the contractor have access to OEM parts for potential repairs?\nIs the contractor licensed in the State of Arkansas by the Elevator Safety Division at the Arkansas Department of Labor and Licensing?\n\nProvide descriptive literature demonstrating the ability to meet the SOW requirements/salient characteristics listed for the product being offered.  Please provide a list of contracts for commercial, federal, state, and local governments.  Listed contracts shall provide communication on the government requirement, illustrating the capability for comparison to the product meeting the specific requirements per the draft SOW.\n\nAll responses to this Sources Sought Notice should be emailed to carmyn.williams@va.gov.  All responses are due by 10:00 AM on Tuesday, 10 February 2026.","origin":"detail"},"contacts":[{"name":"Carmyn E Williams","role":"primary","email":"Carmyn.Williams@va.gov","phone":"713-799-0795","title":"Contract Specialist"}],"place_of_performance":{"zip":"72205","city":{"name":"Little Rock"},"state":{"name":"AR"},"street":"Central Arkansas Veterans Healthcare System (CAVHS)","country":{"code":"USA","name":"UNITED STATES"},"street2":"4300 West 7th Street"},"office_address":{"zip":"39157","city":"RIDGELAND","state":"MS","country":"USA"},"naics_codes":["238290"],"award":{"awardee":{}},"attachments":[{"resource_id":"3b352bc80e004a6e87eaecacef7480c9","name":"36C25626Q0321.docx","kind":"file","mime_type":".docx","size_bytes":53073,"posted_at":"2026-01-22T14:00:40.047Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/3b352bc80e004a6e87eaecacef7480c9/download","mirrored":false}],"awards":[],"related":[{"key":"36C25627Q0112","latest_notice_id":"759ddf998f1141a39cc6c1583716c941","title":"Mobile CT Scanner and technicians for Veterans Affairs Longview TX","solicitation_number":"36C25627Q0112","notice_type":"k","first_type":"k","first_posted":"2026-11-06","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-27T23:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T23:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C256","office_name":"256-NETWORK CONTRACT OFFICE 16 (36C256)","naics":"532490","psc":"W065","set_aside":"SDVOSBS","state":"TX","county":"48183","county_name":"Gregg County","city":"4843888","city_name":"Longview","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C25627Q0092","latest_notice_id":"e26c210473444f428766c394ed401566","title":"N099--JLM Roll Up Door Replacement","solicitation_number":"36C25627Q0092","notice_type":"k","first_type":"k","first_posted":"2026-10-29","last_posted":"2026-11-23","notices":5,"due_at":"2026-11-30T18:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C256","office_name":"256-NETWORK CONTRACT OFFICE 16 (36C256)","naics":"238290","psc":"N099","set_aside":"SDVOSBC","state":"AR","county":"05119","county_name":"Pulaski County","city":"0550450","city_name":"North Little Rock","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C25627Q0087","latest_notice_id":"cd7d881bb8cc47e4b482d18db8376dea","title":"Z2NZ--Turn Key Chiller Equipment (Purchase and Install)","solicitation_number":"36C25627Q0087","notice_type":"o","first_type":"o","first_posted":"2026-10-26","last_posted":"2026-11-16","notices":5,"due_at":"2026-12-02T16:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C256","office_name":"256-NETWORK CONTRACT OFFICE 16 (36C256)","naics":"238220","psc":"Z2NZ","set_aside":"SDVOSBC","state":"NC","county":"37119","county_name":"Mecklenburg County","city":"3752220","city_name":"Pineville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C25626R0130","latest_notice_id":"ae234db09f8948909d14474346f3dbb6","title":"CON | Z1DA | REPLACE OR CHILLERS | 580-23-105 | SOLICITATION","solicitation_number":"36C25626R0130","notice_type":"o","first_type":"p","first_posted":"2026-09-29","last_posted":"2026-10-29","notices":4,"due_at":"2026-12-02T20:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C256","office_name":"256-NETWORK CONTRACT OFFICE 16 (36C256)","naics":"238220","psc":"Z1DA","set_aside":"SDVOSBC","state":"TX","county":"48201","county_name":"Harris County","city":"4835000","city_name":"Houston","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-30T03:41:17.879115Z"},{"key":"36C25627Q0130","latest_notice_id":"45e70dd24a474faab70a857253f95cb5","title":"Floor mat services for Biloxi, MS and Mobile, AL Outpatient Clinic","solicitation_number":"36C25627Q0130","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-12-04T18:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C256","office_name":"256-NETWORK CONTRACT OFFICE 16 (36C256)","naics":"812332","psc":"S209","set_aside":"SBA","state":"MS","county":"28047","county_name":"Harrison County","city":"2806220","city_name":"Biloxi","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"}],"similar_open":[{"key":"36C25627Q0092","latest_notice_id":"e26c210473444f428766c394ed401566","title":"N099--JLM Roll Up Door Replacement","solicitation_number":"36C25627Q0092","notice_type":"k","first_type":"k","first_posted":"2026-10-29","last_posted":"2026-11-23","notices":5,"due_at":"2026-11-30T18:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C256","office_name":"256-NETWORK CONTRACT OFFICE 16 (36C256)","naics":"238290","psc":"N099","set_aside":"SDVOSBC","state":"AR","county":"05119","county_name":"Pulaski County","city":"0550450","city_name":"North Little Rock","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C24827Q0155","latest_notice_id":"831665dca3fc431482f486284606c5a5","title":"J026--Pneumatic Tube System Preventive Maintenance","solicitation_number":"36C24827Q0155","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-26T16:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"238290","psc":"J026","set_aside":null,"state":"PR","county":"72127","county_name":"San Juan Municipio","city":"7276770","city_name":"San Juan","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"15BBNF26Q31000001","latest_notice_id":"10f5ed3071404177847a261c4b7eead4","title":"Replace Elevators at FDC Miami","solicitation_number":"15BBNF26Q31000001","notice_type":"p","first_type":"p","first_posted":"2026-09-28","last_posted":"2026-09-28","notices":1,"due_at":"2026-12-03T18:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-015","dept_name":"JUSTICE, DEPARTMENT OF","sub_key":"s-1540","sub_name":"FEDERAL PRISON SYSTEM / BUREAU OF PRISONS","office_key":"o-15BFA0","office_name":"FAO","naics":"238290","psc":"Z2FF","set_aside":"SBA","state":"FL","county":"12086","county_name":"Miami-Dade County","city":"1245000","city_name":"Miami","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-29T03:58:53.462888Z"}],"similar_open_total":18,"indexable":false}