Solicitation, total small business set-aside, first published as presolicitation
502-Fire Alarm / sprinkler Service Contract (VA-24-00082860) 502-24-3-5048-0215/36C256-24-AP-3612
36C25624Q1010
Department of Veterans Affairs, 256-Network Contract Office 16. Security Systems Services (except Locksmiths).
Awarded
$225,681.14 obligated so far on USAspending
Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities
This one was awarded in 2024
27 like it are open now in security systems services (except locksmiths)
- Fire Monitoring, Inspections, Maintenance, and Remediation Services
Indian Health Service, Lawton Indian Hospital
Sources soughtIndian small businessNAICS 561621Ship to Oklahoma City, OKIHSSS11182026Due todayNov 25 - USCG Station Wachapreague Alarm Monitoring Service
US Coast Guard, Base Portsmouth
SolicitationSmall businessNAICS 561621Wachapreague, VA3030127RFQ000001Due in 5 daysNov 30 - Maintenance and Repair Service for Retractable Security Bollards and Barriers
United States Holocaust Memorial Museum, Ushmm Procurement Division
SolicitationNAICS 561621Washington, DC95476727Q1104Due in 6 daysDec 1
All 27 open in security systems services (except locksmiths)
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Solicitation. A formal request for proposals, quotes or bids. Offers are due by the response deadline. Glossary
- Who may compete
- Total small business set-aside. Only small businesses may compete. Small, under NAICS 561621 (security systems services (except locksmiths)), means no more than $25 million in average annual receipts, counted with affiliates. Open Small business opportunities
- Time to respond
- Bidders had 20 days from the day the solicitation was posted, June 19, 2024, to the deadline. The deadline moved once: it was first June 25, 2024 and ended as July 9, 2024.
- How it ended
- Awarded to United Automation LLC on July 19, 2024, 10 days after offers were due. The contracting office reported 3 offers (competed under simplified acquisition procedures).
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
Fire Alarm & Sprinkler Testing Questions and Answers: In the SOW, section 1.3, "VA will receive 154 hours per year for service and preventative fire sprinkler maintenance and installation." Please clarify. "Installation" projects are treated differently and do not typically fall under "preventative maintenance". These "installation"  projects are typically designed by a VA FPE (fire protection engineer) and generally fall under a construction RFP/RFQ.
Installation is only if a head needs to be relocated, raised or lowered. This is not for projects. In section 1.4, the VA is entitled to 4 8-hour days of afterhours service per quarter.  Does this include emergency call outs for the sprinkler fitter/technician or fire alarm technician only? Fire Alarm only In section 1.6, ...annual testing and inspection of the complete fire alarm system in October.
There is no mention of any sprinkler quarterly, semi-annual or annual testing and inspection. Will the contractor be responsible for testing and inspecting the sprinkler system, according to the NFPA, during the term of this contract?
Sprinkler is tested in house and is not part of this contract In section 1.7, Fire Alarm Technician must be able to respond to fire alarm emergency call outs within 1 hour from the time of call.  Within that 1-hour response time, does a phone call to the property/fire department/engineer on duty, constitute and fall within the required "1 hour response for the fire alarm technician and sprinkler fitter/technician"?  Call does not count and it is only for fire alarm and not sprinkler In Supplies, section 2.2, "...parts needed for repairs or fire pump maintenance."
How many fire pumps does the current facility have? Only one (diesel pump) In Qualifications and Rules for Fire Alarm, section M, "be responsible for any ceiling tiles that may become damaged during construction." Is the contractor "responsible" for supplying the ceiling tiles or are tiles available through the VA maintenance department for replacement if they become damaged Contractor is responsible for any tiles that they damage.
The contract, on USAspending
Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.
- Recipient
- United Automation LLC
- UEI
- GPA5LEQ9T9S3
- CAGE
- 560A1
- Vendor location
- West Monroe, LA
- Contract
- 36C25624P1356, purchase order
- Obligated
- $225,681.14
- Actions
- 2 between July 19, 2024 and November 12, 2025
- Competition
- Competed Under SAP, 3 offers received
- Set-aside reported
- Small Business Set Aside - Total
- Described as
- Annual Service Maintenance on Fire Alarm and Sprinkler Systems to Include Repairs
- Match
- solicitation number 36C25624Q1010 equals the FPDS solicitation identifier; same awarding office 36C256 (high confidence)
- Record
- USAspending award page
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
June 19, 2024
Presolicitation
Due June 25, 2024 at 5:00 PM EDT. SAM.gov, notice 6b1f5208d1a74c289c57440784783419
June 19, 2024
Solicitation, originally presolicitation
Due July 9, 2024 at 5:00 PM EDT. SAM.gov, notice a1c59516a7c04363a00dc46f20825c27
June 24, 2024
Solicitation
Due July 9, 2024 at 5:00 PM EDT. SAM.gov, notice bf690f7ecd534894816c1acc83501a4c
June 25, 2024
Solicitation
Due July 9, 2024 at 5:00 PM EDT. SAM.gov, notice 94f2614ed4614d548e5e8ac58b82acfc
June 25, 2024
Solicitation
Due July 9, 2024 at 5:00 PM EDT. SAM.gov, notice d5a1065b68334059af6d4ec90c0908c2
Points of contact
- Dena A Young, Contracting Officerdena.young@va.gov