{"canonical":"https://sealedbidder.com/opportunities/36c25526q0611","key":"36C25526Q0611","url":"https://sealedbidder.com/opportunities/36c25526q0611","title":"J061--Medical Gas Alarm Cable Services- MRN - MC 657-26-3-2009-0308 (VA-26-00078957)","solicitation_number":"36C25526Q0611","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-08-20T12:00:00Z","first_posted":"2026-08-14","last_posted":"2026-08-14","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"238210","psc":"J061","set_aside":null,"place_state":"IL","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"17199","place_county_name":"Williamson County","place_city":"1746916","place_city_name":"Marion","winner":null,"award_amount":null,"publications":[{"notice_id":"a1012c163c7c45059bb5772afca8b089","title":"J061--Medical Gas Alarm Cable Services- MRN - MC 657-26-3-2009-0308 (VA-26-00078957)","solicitation_number":"36C25526Q0611","notice_type":"r","base_type":"r","posted":"2026-08-14","posted_at":"2026-08-14T19:25:13.509Z","due_at":"2026-08-20T12:00:00Z","due_date":"2026-08-20","cancelled":false,"archived":true,"archive_date":"2026-09-04","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/a1012c163c7c45059bb5772afca8b089/view","enriched":true,"history":[{"index":3,"title":"J061--Medical Gas Alarm Cable Services- MRN - MC 657-26-3-2009-0308 (VA-26-00078957)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-14T19:25:13.509Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"a1012c163c7c45059bb5772afca8b089","solicitation_number":"36C25526Q0611"}]}],"latest_notice_id":"a1012c163c7c45059bb5772afca8b089","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-08-14","posted_at":"2026-08-14T19:25:13.509Z","created_at":"2026-08-14T19:25:11.192Z","modified_at":"2026-09-04T05:06:57.830Z","response_deadline":{"raw":"2026-08-20T07:00:00-05:00","utc":"2026-08-20T12:00:00Z","date":"2026-08-20","time":"07:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/a1012c163c7c45059bb5772afca8b089/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"J061--Medical Gas Alarm Cable Services- MRN - MC 657-26-3-2009-0308 (VA-26-00078957)","agency":{"office":{"code":"36C255","name":"255-NETWORK CONTRACT OFFICE 15 (36C255)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"66048","city":"LEAVENWORTH","state":"KS","country":"USA"},"organization_id":"100186523","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-09-04","archive_type":"auto_custom"},"history":[{"index":3,"title":"J061--Medical Gas Alarm Cable Services- MRN - MC 657-26-3-2009-0308 (VA-26-00078957)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-14T19:25:13.509Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"a1012c163c7c45059bb5772afca8b089","solicitation_number":"36C25526Q0611"}],"contacts":[{"name":"Erika Kobulnicky","role":"primary","email":"Erika.Kobulnicky@va.gov","phone":"913-946-1991","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"a1012c163c7c45059bb5772afca8b089","lineage_id":"a1012c163c7c45059bb5772afca8b089","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-25T00:30:36.718860744Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"717828c963d8346f060271410cf022c9412ffe07c14a885bf4e24bd52ad55499","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-25T00:30:36.718860744Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"SOURCES SOUGHT NOTICE (Market Research Only)\nDepartment of Veterans Affairs (VA)   NCO 15\nMarion VA Medical Center (VAMC), Marion, IL\nMedical Gas Alarm Cable Services\nTHIS IS NOT A SOLICITATION.\nThis Sources Sought Notice is issued solely for market research and planning purposes and does not constitute a solicitation or an obligation on the part of the Government to acquire any products or services. Responses will be treated as information only. The Government will not reimburse any costs associated with responding. Information received may be used by the Department of Veterans Affairs to inform the acquisition approach and performance specifications. Submission of pricing, capabilities, and other market data is permitted in accordance with FAR 15.201(e).\n1. PURPOSE\nThe Department of Veterans Affairs (VA), NCO 15, is conducting market research in accordance with FAR Part 10 to identify capable and interested sources for services to repair and replace deficient medical-gas alarm cabling and integrate identified CO2 alarm(s) with the designated master alarm station at the Marion VAMC. Responses will help the Government finalize the Statement of Work (SOW), determine the acquisition strategy (including small-business considerations), and assess industry capability. The Government may not answer vendor questions at this time.\n2. NAICS & BUSINESS INFORMATION\nNAICS Code: 238210   Electrical Contractors and Other Wiring Installation Contractors\nSBA Size Standard: $19.0 million (revenue).\nSocio economic status: Vendors shall indicate SDVOSB/VOSB (VetCert if applicable), WOSB, 8(a), HUBZone, Small/Large, etc.\n3. PLACE OF PERFORMANCE\nMarion VAMC\n2401 West Main Street\nMarion, Illinois\n4. REQUIREMENT SUMMARY\nThe VA Heartland Network 15 Contracting Office seeks a qualified contractor to furnish all labor, supervision, tools, equipment, materials, transportation, testing, documentation, and incidentals necessary to restore reliable, accurate, and identifiable alarm signaling for medical gas alarm circuits at the Marion VA Medical Center. Refer to the Statement of Work (SOW) which will follow this notice for additional details.\n5. REQUESTED VENDOR INFORMATION\nSubmit a capability statement (maximum 5 pages) including:\n  Company Name, Address, and Point of Contact (name, phone, email).\n  UEI, CAGE, and Tax ID.\n  Business size under NAICS 238210 and socio economic status (SDVOSB, VOSB, WOSB, 8(a), HUBZone, Small/Large).\n  Relevant experience performing medical gas alarm repair/installation/integration in occupied healthcare facilities (include references).\n  Personnel qualifications/certifications (ASSE 6040/6010/6020/6030 as applicable) and any manufacturer training/authorization.\n  Approach to cable repair/replacement, CO2 alarm integration, testing/commissioning, and measures to protect facility operations.\n  Applicable contract vehicles (FSS, GSA, IDIQ, BPA) and contract numbers, if available.\n6. SUBMISSION INSTRUCTIONS\nResponses Due: Thursday, August 20, 2026 by 7:00 AM Central Time (CT)\nSubmission Method: Email PDF capability statement to: Erika M. Kobulnicky, Contract Specialist   Erika.Kobulnicky@va.gov\nSubject Line:  Sources Sought Response   Medical Gas Alarm Cable Repair (Marion VAMC) \n7. ADDITIONAL INFORMATION\nThis notice shall not be construed as a commitment by the Government to issue a solicitation or award a contract, nor does it restrict the Government s acquisition approach. Based on responses, the Government may consider set asides for SDVOSBs, VOSBs, or another small business category; if inadequate small business response is received, alternate set asides or full and open competition may be considered in accordance with Public Law 109 461, Section 8127 (Veterans Benefits Act).\n8. IMPORTANT NOTES\n  This notice is for market research only and does not constitute a solicitation.\n  The Government may not respond to questions at this time; vendors should submit capability statements based on this notice.\n  Proprietary information must be clearly marked.\n  No telephone inquiries will be accepted.\n  The Statement of Work (SOW) will follow this notice and is subject to change based on market research and internal review.\n9. STATEMENT OF WORK (TO FOLLOW)\nThe SOW may be revised based on market research feedback.\nStatement of Work\nMedical Gas Alarm Cable Services\n1. Purpose\nThe Department of Veterans Affairs (VA), Marion VA Medical Center (VAMC), requires repair and replacement of deficient medical-gas alarm cabling and integration of identified CO2 alarm(s) with the designated master alarm station. The work is required to restore reliable, accurate, and identifiable alarm signaling for the affected medical-gas alarm circuits.\n2. Scope and Required Outcome\nThe contractor shall furnish all management, labor, supervision, tools, equipment, materials, transportation, testing, documentation, and incidentals necessary to complete the work described in this SOW, except for Government-furnished information expressly identified in Section 6.\nThe completed work shall provide the following outcomes:\nCorrect and reliable alarm communication between the identified originating locations and the designated master alarm station.\nCorrect alarm identification, alarm activation, normal condition, and restoration indication for every affected circuit.\nCable routing, termination, labeling, testing, and documentation that are compatible with the existing medical-gas alarm system, applicable codes and standards, manufacturer instructions, and VA facility requirements.\nA safe, operational, tested, documented, and VA-accepted system no later than 45 calendar days after the notice to proceed (NTP).\n3. Locations of Work\nWork will occur at the Marion VAMC, 2401 West Main Street, Marion, Illinois, including the following known locations:\nBuilding 2, electrical room G115, outside the Kitchen.\nBuilding 42, mechanical room A109.\nBuilding 2, Room 245.\nBuilding 42, Emergency Department Medical Service Area (ED MSA) office/master alarm-panel location.\nBefore starting work, the contractor shall conduct a site survey with the VA-designated representative to verify access, cable pathways, alarm-panel locations, cable endpoints, circuit identification, and existing conditions. The contractor shall promptly notify the COR in writing of site conditions that conflict with this SOW or prevent compliant performance.\n4. Technical Requirements\n4.1 Existing cable repair/replacement\nThe contractor shall:\nIdentify the affected existing medical-gas alarm cable connections and correct compromised, spliced, extended, improperly routed, mixed-up, or otherwise deficient connections within the defined work area.\nFurnish and install one 16-pair cable assembly, or other cable configuration approved in writing by the COR after field verification, between electrical room G115 in Building 2 and mechanical room A109 in Building 42.\nVerify the cable type, conductor size, shielding, listing, pathway, and terminations required for compatibility with the existing alarm equipment before procuring material. Materials shall be new and compatible with the existing system and manufacturer requirements.\nRoute cable in an approved pathway and protect it from physical damage. The contractor shall not use unapproved pathways or penetrate fire/smoke barriers without VA approval and required firestopping.\nTerminate, identify, and label cables at both endpoints. Labels shall correspond to the approved cable schedule and affected alarm point(s).\n\n4.2 CO2 master alarm connection\nThe contractor shall:\nFurnish and install cable between Building 2, Room 245, and the designated master panel in the Building 42 ED MSA office.\nVerify the precise endpoint, signal type, alarm-panel compatibility, and required cable characteristics during the pre-work survey.\nTerminate, identify, and label the cable at both endpoints.\nConnect and commission the identified CO2 alarm(s) so that the required alarm condition, normal condition, and restoration indication are accurately displayed at the designated master panel.\n\n4.3 Work plan and outages\nAt least 10 calendar days after NTP, and before beginning field work, the contractor shall submit a work plan to the COR for review. The plan shall include the proposed schedule, site access requirements, cable routes, affected equipment/circuits, anticipated shutdowns or alarm impairments, protective measures, testing sequence, and contingency/restoration procedures.\nThe contractor shall not begin work that may impair an alarm circuit, medical-gas alarm indication, or related facility operation until the VA-designated representative has approved the work window and required coordination. The contractor shall immediately notify the COR and VA-designated representative of an unintended alarm impairment, malfunction, or unsafe condition and shall take prompt action to restore the affected system.\n\n5. Standards, Safety, and Contractor Qualifications\n5.1 Applicable Requirements\nThe contractor shall comply with all applicable Federal, state, local, VA, facility, manufacturer, and code requirements, including the edition of NFPA 99 adopted or otherwise specified by the VA facility for this project.\nThe contractor shall comply with all VA facility requirements for medical-gas alarm impairments, permit-to-work procedures, infection-control measures, life-safety, firestopping, access, safety, and emergency restoration.\n\n5.2 Contractor Experience\nThe contractor shall demonstrate a minimum of three years of successful experience performing medical-gas alarm repair, installation, troubleshooting, testing, or commissioning in occupied healthcare facilities.\nBefore beginning work, the contractor shall submit three references for completed projects of similar scope and complexity. Each reference shall include:\nFacility name and location.\nDescription of the medical-gas alarm work performed.\nContract or project completion date.\nCustomer point of contact, telephone number, and email address.\nIdentification of whether the work included alarm cabling, alarm-panel integration, troubleshooting, testing, commissioning, or system restoration.\n\n5.3 Personnel Qualifications\nThe contractor shall provide qualified personnel with demonstrated experience in medical-gas alarm systems, low-voltage control wiring, cable termination, alarm-panel troubleshooting, functional testing, and commissioning.\nBefore beginning field work, the contractor shall submit the following for the project manager and each technician assigned to perform work:\nResume or work history showing relevant medical-gas alarm and healthcare-facility experience.\nApplicable state or local electrical license, if required by the jurisdiction for the work being performed.\nCurrent training certificates, professional credentials, and medical-gas qualifications applicable to the assigned work.\nDocumentation of manufacturer training, manufacturer authorization, or equivalent demonstrated competence for the existing medical-gas alarm equipment to be serviced.\n\nTechnicians performing maintenance, troubleshooting, testing, repair, or commissioning of medical-gas alarm equipment shall possess ASSE 6040 Medical Gas Systems Maintenance Personnel certification, or alternate written qualifications accepted by the VA medical-gas Responsible Facility Authority (RFA) before field work begins.\n\nIf the scope includes installation or modification of medical-gas-system components beyond alarm cabling and panel connections, including piping, outlets, valves, sensors connected to the pipeline system, or source equipment, personnel performing that installation work shall meet ASSE 6010 Medical Gas Systems Installer requirements.\n\nIf the VA RFA determines that inspection or independent verification is required, inspection and/or verification shall be performed by qualified ASSE 6020 Medical Gas Systems Inspector and/or ASSE 6030 Medical Gas Systems Verifier personnel, as applicable. The verifier shall be independent of the contractor performing the installation or repair work.\n\n5.4 Medical-Gas Coordination\nBefore beginning any work that may affect alarm function, medical-gas alarm indications, or facility operations, the contractor shall coordinate with the COR and the VA-designated Engineering Service and medical-gas RFA representative.\nThe contractor shall submit a written work plan for VA review before beginning field work. At a minimum, the work plan shall identify:\nAffected alarm panels, circuits, alarm points, and cable routes.\nProposed work sequence and work schedule.\nPlanned alarm impairments, shutdowns, or temporary monitoring measures.\nMeasures to protect patient safety and maintain facility operations.\nTesting and restoration procedures.\nEmergency contacts and contingency actions for an unplanned alarm-system malfunction or impairment.\nThe contractor shall not impair, disconnect, alter, or place out of service an alarm circuit without prior coordination and approval through the VA facility s applicable impairment and permit-to-work process.\n\n5.5 Safety and Protection of Government Property\nThe contractor shall secure tools and equipment at all times. Tools and equipment shall be removed from open areas or placed in an approved secured location during breaks, at the end of each workday, and whenever not in active use.\nThe contractor shall remove debris from the facility at the end of each workday and upon completion of the work. The contractor shall protect Government property and repair, at no additional cost to the Government and subject to VA approval, damage caused by the contractor or its employees.\nSmoking is prohibited on VAMC property.\n\n6. Government-Furnished Information and Coordination\nThe Government will provide reasonable access to the work locations and available existing system information, including available drawings, panel information, and known circuit information. The Government will identify the COR and the appropriate Engineering/medical-gas representative for coordination.\nThe contractor shall not rely on incomplete or unavailable drawings as a basis to omit necessary site verification. The contractor shall document field-verified conditions and proposed deviations from the approved plan for COR review before implementing a deviation.\n\n7. Submittals and Deliverables\nThe contractor shall provide the following to the COR:\nDeliverable\nDue date\nPersonnel qualifications/certifications, as applicable\nBefore beginning field work\nSite-survey findings, cable schedule, and proposed routing\nBefore installation\nWork plan, schedule, and outage/impairment plan\nWithin 10 calendar days after NTP and before field work\nProduct data for proposed cable, terminations, and related materials\nBefore installation\nDaily status report while an alarm circuit is impaired, if applicable\nBy the end of each affected workday\nSigned functional test report for every affected circuit/alarm point\nAt completion of testing\nMarked-up as-built drawing and final cable schedule identifying routes, endpoints, terminations, labels, and approved deviations\nBefore final acceptance\nWarranty information and closeout package\nBefore final acceptance\n\n8. Testing, Inspection, and Acceptance\nThe contractor shall coordinate all testing with the COR and VA-designated Engineering/medical-gas representative. The contractor shall provide all test equipment and personnel required for contractor testing.\nFor each affected circuit and alarm point, the contractor shall test and document, at a minimum:\nContinuity and correct point-to-point termination.\nCorrect alarm activation and identification at the designated master alarm station.\nNormal-condition indication after testing.\nCorrect restoration indication following simulated alarm activation.\nProper labeling and correlation of field labels, panel labels, cable schedule, and as-built documentation.\n\nThe work is acceptable only when all of the following are complete:\nEach affected alarm point operates correctly and communicates the correct status and identification to the designated master panel.\nAll cable routing, terminations, labels, and protective measures comply with the approved work plan, applicable requirements, and manufacturer instructions.\nRequired test records and closeout deliverables have been submitted and are complete.\nVA has completed final inspection and provided written acceptance through the COR or other authorized VA official.\nThe contractor shall correct deficiencies identified during testing or inspection at no additional cost to the Government and retest the corrected work.\n\n9. Period and Place of Performance\nThe period of performance is 45 calendar days after NTP. The place of performance is the Marion VAMC, 2401 West Main Street, Marion, Illinois, at the locations identified in Section 3 and any approved associated access pathways within the facility.\n\n10. Payment\nPayment terms and contract line item structure will be established in the solicitation and resulting contract. Final payment is contingent on completion and Government acceptance of all required work and deliverables.\n\n11. Contract Administration\nThe COR may monitor performance and inspect deliverables but may not authorize changes to contract scope, price, period of performance, or other contract terms. Only the Contracting Officer may make such changes in writing.\nAll contract administration functions will be retained by the Department of Veterans Affairs.\nThe Contracting Officer will be the only person authorized to approve changes or modify any of\nthe requirements under this contract. The Contractor shall communicate with the Contracting\nOfficer on all matters pertaining to contract administration. Only the Contracting Officer will be\nauthorized to make commitments or issue changes that affect price, quantity, or quality of\nperformance of this contract. In the event the Contractor effects any such change at the direction of any person other than the Contracting Officer, the change shall be considered unauthorized and no adjustment will be made in the contract price to cover any increase in costs incurred as a result thereof.\n\n 12. Contracting Officer s Representative\n Pursuant to VAAR Provision 852.270-1, Representatives of Contracting Officer, the\ndesignated representative for this contract will be determined at award.\n\n13. Acronyms and Definitions\nCDR: Contract Discrepancy Report. Report issued by the Government to the contractor to\ndocument a supply or service found to be unacceptable during contract performance.\nCLIN: Contract Line-Item Number. Unit of work (or service) to be performed (or delivered) by the contractor as a pay item.\nCO: Contracting Officer. A person with the authority to enter into, administer, and/or terminate\ncontracts and make related determinations and findings.\nCOR: Contracting Officer s Representative. An individual, including a Contracting Officer s\nRepresentative (COR), designated and authorized in writing by the contracting officer to perform\nspecific technical or administrative functions.\nQA: Quality Assurance. Actions taken by the government to assure contracted services meet PWS requirements.\n\n14. Personnel\nNon-Personal Services\nThis is a non-personal services contract. Personnel rendering services under this contract are not subject either by the contract s terms or by the manner of its administration, to the supervision and control usually prevailing in relationships between the government and its employees. The Government shall not exercise any supervision or control over the contract service s performing services herein. Such contract service s shall be accountable solely to the Contractor who, in turn, is responsible to the Government. Contractor Compliance with the Immigration and Nationality Act of 1952 The Contractor shall comply with any and all legal provisions contained in the Immigration and Nationality Act of 1952, As Amended; its related laws and regulations that are enforced by Homeland Security, Immigration and Customs Enforcement and the U.S Department of Labor as these may relate to non-immigrant foreign nationals working under contract or subcontract for the Contractor while providing services to Department of Veterans Affairs patient referrals.\n\n15. Hours of Operations\nBusiness hours for the VAMC follow:\na. Administrative hours: Monday through Friday, 8:00 a.m. - 4:30 p.m.\nb. National Holidays: The 11 holidays observed by the Federal Government are:\nNew Year s Day;\nMartin Luther King s Birthday;\nPresidents Day;\nMemorial Day;\nJuneteenth Independence Day\nIndependence Day;\nLabor Day;\nColumbus Day;\nVeterans Day;\nThanksgiving;\nChristmas; and any other day specifically declared by the President of the United States to be a national holiday.\nc. Off-Duty hours: Friday through Monday, 4:30 p.m. - 8:00 a.m.; Monday through Thursday, 4:30 pm   8:00 am.\n\n16. Quality Control\nCONTRACT PERFORMANCE MONITORING. The COR may perform surveillance of\nservices by any of the methods listed below:\na.  Observing actual performance;\nb.  Inspecting the services to determine whether or not the performance meets the performance standards; and\nc.  Review of any other appropriate records.\n\n(1) When unacceptable performance occurs, the COR shall inform the Contractor and the Contracting Officer. This will normally be in writing unless circumstances necessitate verbal communication. In any case the COR shall document the discussion and place it in the COR file.\nWhen the COR determines formal written communication is required, the COR shall prepare a Contract Discrepancy Report (CDR) and present it to the contractor program manager. The Contractor shall acknowledge receipt of the CDR in writing. The CDR will specify if the Contractor is required to prepare a corrective action plan to document how the Contractor shall correct the unacceptable performance and avoid a recurrence. The CDR will also state how long after receipt the Contractor has to present this corrective action plan to the COR. The Government shall review the Contractor corrective action plan to determine acceptability. Any CDRs may become a part of the supporting documentation for any contractual action deemed necessary by the Contracting Officer.\n\n(2) Pursuant to VAAR Provision 852.270-1, Representatives of Contracting Officer\nrepresentative(s); The Government shall periodically evaluate the Contractor performance by appointing a Contracting Officers Representative (COR) to monitor performance to ensure services are received. The Government representative(s) shall evaluate the Contractor performance through inspections of observations, inspection of services or any other form of documentation and all complaints from VA personnel. The Government may inspect as each task is completed or increase the number of quality assurance inspections if deemed appropriate because of repeated failures or because of repeated customer complaints. Likewise, the Government may decrease the number of quality assurance inspections if performance dictates. The Government Contracting Officer shall make final determination of the validity of customer complaint(s).\n\n(3) If any of the services do not conform to contract requirements, the Government may require the Contractor to perform the services again in conformity with contract requirements, at no increase in contract amount. When the defects in services cannot be corrected by re-performance, the Government may require the Contractor to take necessary action to ensure that future performance conforms to contract requirements at no additional cost to the Government.\n\n17. Contract Security\nThe C&A requirements do not apply and a Security Accreditation Package is not required.","text":"SOURCES SOUGHT NOTICE (Market Research Only)\nDepartment of Veterans Affairs (VA) NCO 15\nMarion VA Medical Center (VAMC), Marion, IL\nMedical Gas Alarm Cable Services\nTHIS IS NOT A SOLICITATION.\nThis Sources Sought Notice is issued solely for market research and planning purposes and does not constitute a solicitation or an obligation on the part of the Government to acquire any products or services. Responses will be treated as information only. The Government will not reimburse any costs associated with responding. Information received may be used by the Department of Veterans Affairs to inform the acquisition approach and performance specifications. Submission of pricing, capabilities, and other market data is permitted in accordance with FAR 15.201(e).\n1. PURPOSE\nThe Department of Veterans Affairs (VA), NCO 15, is conducting market research in accordance with FAR Part 10 to identify capable and interested sources for services to repair and replace deficient medical-gas alarm cabling and integrate identified CO2 alarm(s) with the designated master alarm station at the Marion VAMC. Responses will help the Government finalize the Statement of Work (SOW), determine the acquisition strategy (including small-business considerations), and assess industry capability. The Government may not answer vendor questions at this time.\n2. NAICS & BUSINESS INFORMATION\nNAICS Code: 238210 Electrical Contractors and Other Wiring Installation Contractors\nSBA Size Standard: $19.0 million (revenue).\nSocio economic status: Vendors shall indicate SDVOSB/VOSB (VetCert if applicable), WOSB, 8(a), HUBZone, Small/Large, etc.\n3. PLACE OF PERFORMANCE\nMarion VAMC\n2401 West Main Street\nMarion, Illinois\n4. REQUIREMENT SUMMARY\nThe VA Heartland Network 15 Contracting Office seeks a qualified contractor to furnish all labor, supervision, tools, equipment, materials, transportation, testing, documentation, and incidentals necessary to restore reliable, accurate, and identifiable alarm signaling for medical gas alarm circuits at the Marion VA Medical Center. Refer to the Statement of Work (SOW) which will follow this notice for additional details.\n5. REQUESTED VENDOR INFORMATION\nSubmit a capability statement (maximum 5 pages) including:\nCompany Name, Address, and Point of Contact (name, phone, email).\nUEI, CAGE, and Tax ID.\nBusiness size under NAICS 238210 and socio economic status (SDVOSB, VOSB, WOSB, 8(a), HUBZone, Small/Large).\nRelevant experience performing medical gas alarm repair/installation/integration in occupied healthcare facilities (include references).\nPersonnel qualifications/certifications (ASSE 6040/6010/6020/6030 as applicable) and any manufacturer training/authorization.\nApproach to cable repair/replacement, CO2 alarm integration, testing/commissioning, and measures to protect facility operations.\nApplicable contract vehicles (FSS, GSA, IDIQ, BPA) and contract numbers, if available.\n6. SUBMISSION INSTRUCTIONS\nResponses Due: Thursday, August 20, 2026 by 7:00 AM Central Time (CT)\nSubmission Method: Email PDF capability statement to: Erika M. Kobulnicky, Contract Specialist Erika.Kobulnicky@va.gov\nSubject Line: Sources Sought Response Medical Gas Alarm Cable Repair (Marion VAMC)\n7. ADDITIONAL INFORMATION\nThis notice shall not be construed as a commitment by the Government to issue a solicitation or award a contract, nor does it restrict the Government s acquisition approach. Based on responses, the Government may consider set asides for SDVOSBs, VOSBs, or another small business category; if inadequate small business response is received, alternate set asides or full and open competition may be considered in accordance with Public Law 109 461, Section 8127 (Veterans Benefits Act).\n8. IMPORTANT NOTES\nThis notice is for market research only and does not constitute a solicitation.\nThe Government may not respond to questions at this time; vendors should submit capability statements based on this notice.\nProprietary information must be clearly marked.\nNo telephone inquiries will be accepted.\nThe Statement of Work (SOW) will follow this notice and is subject to change based on market research and internal review.\n9. STATEMENT OF WORK (TO FOLLOW)\nThe SOW may be revised based on market research feedback.\nStatement of Work\nMedical Gas Alarm Cable Services\n1. Purpose\nThe Department of Veterans Affairs (VA), Marion VA Medical Center (VAMC), requires repair and replacement of deficient medical-gas alarm cabling and integration of identified CO2 alarm(s) with the designated master alarm station. The work is required to restore reliable, accurate, and identifiable alarm signaling for the affected medical-gas alarm circuits.\n2. Scope and Required Outcome\nThe contractor shall furnish all management, labor, supervision, tools, equipment, materials, transportation, testing, documentation, and incidentals necessary to complete the work described in this SOW, except for Government-furnished information expressly identified in Section 6.\nThe completed work shall provide the following outcomes:\nCorrect and reliable alarm communication between the identified originating locations and the designated master alarm station.\nCorrect alarm identification, alarm activation, normal condition, and restoration indication for every affected circuit.\nCable routing, termination, labeling, testing, and documentation that are compatible with the existing medical-gas alarm system, applicable codes and standards, manufacturer instructions, and VA facility requirements.\nA safe, operational, tested, documented, and VA-accepted system no later than 45 calendar days after the notice to proceed (NTP).\n3. Locations of Work\nWork will occur at the Marion VAMC, 2401 West Main Street, Marion, Illinois, including the following known locations:\nBuilding 2, electrical room G115, outside the Kitchen.\nBuilding 42, mechanical room A109.\nBuilding 2, Room 245.\nBuilding 42, Emergency Department Medical Service Area (ED MSA) office/master alarm-panel location.\nBefore starting work, the contractor shall conduct a site survey with the VA-designated representative to verify access, cable pathways, alarm-panel locations, cable endpoints, circuit identification, and existing conditions. The contractor shall promptly notify the COR in writing of site conditions that conflict with this SOW or prevent compliant performance.\n4. Technical Requirements\n4.1 Existing cable repair/replacement\nThe contractor shall:\nIdentify the affected existing medical-gas alarm cable connections and correct compromised, spliced, extended, improperly routed, mixed-up, or otherwise deficient connections within the defined work area.\nFurnish and install one 16-pair cable assembly, or other cable configuration approved in writing by the COR after field verification, between electrical room G115 in Building 2 and mechanical room A109 in Building 42.\nVerify the cable type, conductor size, shielding, listing, pathway, and terminations required for compatibility with the existing alarm equipment before procuring material. Materials shall be new and compatible with the existing system and manufacturer requirements.\nRoute cable in an approved pathway and protect it from physical damage. The contractor shall not use unapproved pathways or penetrate fire/smoke barriers without VA approval and required firestopping.\nTerminate, identify, and label cables at both endpoints. Labels shall correspond to the approved cable schedule and affected alarm point(s).\n\n4.2 CO2 master alarm connection\nThe contractor shall:\nFurnish and install cable between Building 2, Room 245, and the designated master panel in the Building 42 ED MSA office.\nVerify the precise endpoint, signal type, alarm-panel compatibility, and required cable characteristics during the pre-work survey.\nTerminate, identify, and label the cable at both endpoints.\nConnect and commission the identified CO2 alarm(s) so that the required alarm condition, normal condition, and restoration indication are accurately displayed at the designated master panel.\n\n4.3 Work plan and outages\nAt least 10 calendar days after NTP, and before beginning field work, the contractor shall submit a work plan to the COR for review. The plan shall include the proposed schedule, site access requirements, cable routes, affected equipment/circuits, anticipated shutdowns or alarm impairments, protective measures, testing sequence, and contingency/restoration procedures.\nThe contractor shall not begin work that may impair an alarm circuit, medical-gas alarm indication, or related facility operation until the VA-designated representative has approved the work window and required coordination. The contractor shall immediately notify the COR and VA-designated representative of an unintended alarm impairment, malfunction, or unsafe condition and shall take prompt action to restore the affected system.\n\n5. Standards, Safety, and Contractor Qualifications\n5.1 Applicable Requirements\nThe contractor shall comply with all applicable Federal, state, local, VA, facility, manufacturer, and code requirements, including the edition of NFPA 99 adopted or otherwise specified by the VA facility for this project.\nThe contractor shall comply with all VA facility requirements for medical-gas alarm impairments, permit-to-work procedures, infection-control measures, life-safety, firestopping, access, safety, and emergency restoration.\n\n5.2 Contractor Experience\nThe contractor shall demonstrate a minimum of three years of successful experience performing medical-gas alarm repair, installation, troubleshooting, testing, or commissioning in occupied healthcare facilities.\nBefore beginning work, the contractor shall submit three references for completed projects of similar scope and complexity. Each reference shall include:\nFacility name and location.\nDescription of the medical-gas alarm work performed.\nContract or project completion date.\nCustomer point of contact, telephone number, and email address.\nIdentification of whether the work included alarm cabling, alarm-panel integration, troubleshooting, testing, commissioning, or system restoration.\n\n5.3 Personnel Qualifications\nThe contractor shall provide qualified personnel with demonstrated experience in medical-gas alarm systems, low-voltage control wiring, cable termination, alarm-panel troubleshooting, functional testing, and commissioning.\nBefore beginning field work, the contractor shall submit the following for the project manager and each technician assigned to perform work:\nResume or work history showing relevant medical-gas alarm and healthcare-facility experience.\nApplicable state or local electrical license, if required by the jurisdiction for the work being performed.\nCurrent training certificates, professional credentials, and medical-gas qualifications applicable to the assigned work.\nDocumentation of manufacturer training, manufacturer authorization, or equivalent demonstrated competence for the existing medical-gas alarm equipment to be serviced.\n\nTechnicians performing maintenance, troubleshooting, testing, repair, or commissioning of medical-gas alarm equipment shall possess ASSE 6040 Medical Gas Systems Maintenance Personnel certification, or alternate written qualifications accepted by the VA medical-gas Responsible Facility Authority (RFA) before field work begins.\n\nIf the scope includes installation or modification of medical-gas-system components beyond alarm cabling and panel connections, including piping, outlets, valves, sensors connected to the pipeline system, or source equipment, personnel performing that installation work shall meet ASSE 6010 Medical Gas Systems Installer requirements.\n\nIf the VA RFA determines that inspection or independent verification is required, inspection and/or verification shall be performed by qualified ASSE 6020 Medical Gas Systems Inspector and/or ASSE 6030 Medical Gas Systems Verifier personnel, as applicable. The verifier shall be independent of the contractor performing the installation or repair work.\n\n5.4 Medical-Gas Coordination\nBefore beginning any work that may affect alarm function, medical-gas alarm indications, or facility operations, the contractor shall coordinate with the COR and the VA-designated Engineering Service and medical-gas RFA representative.\nThe contractor shall submit a written work plan for VA review before beginning field work. At a minimum, the work plan shall identify:\nAffected alarm panels, circuits, alarm points, and cable routes.\nProposed work sequence and work schedule.\nPlanned alarm impairments, shutdowns, or temporary monitoring measures.\nMeasures to protect patient safety and maintain facility operations.\nTesting and restoration procedures.\nEmergency contacts and contingency actions for an unplanned alarm-system malfunction or impairment.\nThe contractor shall not impair, disconnect, alter, or place out of service an alarm circuit without prior coordination and approval through the VA facility s applicable impairment and permit-to-work process.\n\n5.5 Safety and Protection of Government Property\nThe contractor shall secure tools and equipment at all times. Tools and equipment shall be removed from open areas or placed in an approved secured location during breaks, at the end of each workday, and whenever not in active use.\nThe contractor shall remove debris from the facility at the end of each workday and upon completion of the work. The contractor shall protect Government property and repair, at no additional cost to the Government and subject to VA approval, damage caused by the contractor or its employees.\nSmoking is prohibited on VAMC property.\n\n6. Government-Furnished Information and Coordination\nThe Government will provide reasonable access to the work locations and available existing system information, including available drawings, panel information, and known circuit information. The Government will identify the COR and the appropriate Engineering/medical-gas representative for coordination.\nThe contractor shall not rely on incomplete or unavailable drawings as a basis to omit necessary site verification. The contractor shall document field-verified conditions and proposed deviations from the approved plan for COR review before implementing a deviation.\n\n7. Submittals and Deliverables\nThe contractor shall provide the following to the COR:\nDeliverable\nDue date\nPersonnel qualifications/certifications, as applicable\nBefore beginning field work\nSite-survey findings, cable schedule, and proposed routing\nBefore installation\nWork plan, schedule, and outage/impairment plan\nWithin 10 calendar days after NTP and before field work\nProduct data for proposed cable, terminations, and related materials\nBefore installation\nDaily status report while an alarm circuit is impaired, if applicable\nBy the end of each affected workday\nSigned functional test report for every affected circuit/alarm point\nAt completion of testing\nMarked-up as-built drawing and final cable schedule identifying routes, endpoints, terminations, labels, and approved deviations\nBefore final acceptance\nWarranty information and closeout package\nBefore final acceptance\n\n8. Testing, Inspection, and Acceptance\nThe contractor shall coordinate all testing with the COR and VA-designated Engineering/medical-gas representative. The contractor shall provide all test equipment and personnel required for contractor testing.\nFor each affected circuit and alarm point, the contractor shall test and document, at a minimum:\nContinuity and correct point-to-point termination.\nCorrect alarm activation and identification at the designated master alarm station.\nNormal-condition indication after testing.\nCorrect restoration indication following simulated alarm activation.\nProper labeling and correlation of field labels, panel labels, cable schedule, and as-built documentation.\n\nThe work is acceptable only when all of the following are complete:\nEach affected alarm point operates correctly and communicates the correct status and identification to the designated master panel.\nAll cable routing, terminations, labels, and protective measures comply with the approved work plan, applicable requirements, and manufacturer instructions.\nRequired test records and closeout deliverables have been submitted and are complete.\nVA has completed final inspection and provided written acceptance through the COR or other authorized VA official.\nThe contractor shall correct deficiencies identified during testing or inspection at no additional cost to the Government and retest the corrected work.\n\n9. Period and Place of Performance\nThe period of performance is 45 calendar days after NTP. The place of performance is the Marion VAMC, 2401 West Main Street, Marion, Illinois, at the locations identified in Section 3 and any approved associated access pathways within the facility.\n\n10. Payment\nPayment terms and contract line item structure will be established in the solicitation and resulting contract. Final payment is contingent on completion and Government acceptance of all required work and deliverables.\n\n11. Contract Administration\nThe COR may monitor performance and inspect deliverables but may not authorize changes to contract scope, price, period of performance, or other contract terms. Only the Contracting Officer may make such changes in writing.\nAll contract administration functions will be retained by the Department of Veterans Affairs.\nThe Contracting Officer will be the only person authorized to approve changes or modify any of\nthe requirements under this contract. The Contractor shall communicate with the Contracting\nOfficer on all matters pertaining to contract administration. Only the Contracting Officer will be\nauthorized to make commitments or issue changes that affect price, quantity, or quality of\nperformance of this contract. In the event the Contractor effects any such change at the direction of any person other than the Contracting Officer, the change shall be considered unauthorized and no adjustment will be made in the contract price to cover any increase in costs incurred as a result thereof.\n\n12. Contracting Officer s Representative\nPursuant to VAAR Provision 852.270-1, Representatives of Contracting Officer, the\ndesignated representative for this contract will be determined at award.\n\n13. Acronyms and Definitions\nCDR: Contract Discrepancy Report. Report issued by the Government to the contractor to\ndocument a supply or service found to be unacceptable during contract performance.\nCLIN: Contract Line-Item Number. Unit of work (or service) to be performed (or delivered) by the contractor as a pay item.\nCO: Contracting Officer. A person with the authority to enter into, administer, and/or terminate\ncontracts and make related determinations and findings.\nCOR: Contracting Officer s Representative. An individual, including a Contracting Officer s\nRepresentative (COR), designated and authorized in writing by the contracting officer to perform\nspecific technical or administrative functions.\nQA: Quality Assurance. Actions taken by the government to assure contracted services meet PWS requirements.\n\n14. Personnel\nNon-Personal Services\nThis is a non-personal services contract. Personnel rendering services under this contract are not subject either by the contract s terms or by the manner of its administration, to the supervision and control usually prevailing in relationships between the government and its employees. The Government shall not exercise any supervision or control over the contract service s performing services herein. Such contract service s shall be accountable solely to the Contractor who, in turn, is responsible to the Government. Contractor Compliance with the Immigration and Nationality Act of 1952 The Contractor shall comply with any and all legal provisions contained in the Immigration and Nationality Act of 1952, As Amended; its related laws and regulations that are enforced by Homeland Security, Immigration and Customs Enforcement and the U.S Department of Labor as these may relate to non-immigrant foreign nationals working under contract or subcontract for the Contractor while providing services to Department of Veterans Affairs patient referrals.\n\n15. Hours of Operations\nBusiness hours for the VAMC follow:\na. Administrative hours: Monday through Friday, 8:00 a.m. - 4:30 p.m.\nb. National Holidays: The 11 holidays observed by the Federal Government are:\nNew Year s Day;\nMartin Luther King s Birthday;\nPresidents Day;\nMemorial Day;\nJuneteenth Independence Day\nIndependence Day;\nLabor Day;\nColumbus Day;\nVeterans Day;\nThanksgiving;\nChristmas; and any other day specifically declared by the President of the United States to be a national holiday.\nc. Off-Duty hours: Friday through Monday, 4:30 p.m. - 8:00 a.m.; Monday through Thursday, 4:30 pm 8:00 am.\n\n16. Quality Control\nCONTRACT PERFORMANCE MONITORING. The COR may perform surveillance of\nservices by any of the methods listed below:\na. Observing actual performance;\nb. Inspecting the services to determine whether or not the performance meets the performance standards; and\nc. Review of any other appropriate records.\n\n(1) When unacceptable performance occurs, the COR shall inform the Contractor and the Contracting Officer. This will normally be in writing unless circumstances necessitate verbal communication. In any case the COR shall document the discussion and place it in the COR file.\nWhen the COR determines formal written communication is required, the COR shall prepare a Contract Discrepancy Report (CDR) and present it to the contractor program manager. The Contractor shall acknowledge receipt of the CDR in writing. The CDR will specify if the Contractor is required to prepare a corrective action plan to document how the Contractor shall correct the unacceptable performance and avoid a recurrence. The CDR will also state how long after receipt the Contractor has to present this corrective action plan to the COR. The Government shall review the Contractor corrective action plan to determine acceptability. Any CDRs may become a part of the supporting documentation for any contractual action deemed necessary by the Contracting Officer.\n\n(2) Pursuant to VAAR Provision 852.270-1, Representatives of Contracting Officer\nrepresentative(s); The Government shall periodically evaluate the Contractor performance by appointing a Contracting Officers Representative (COR) to monitor performance to ensure services are received. The Government representative(s) shall evaluate the Contractor performance through inspections of observations, inspection of services or any other form of documentation and all complaints from VA personnel. The Government may inspect as each task is completed or increase the number of quality assurance inspections if deemed appropriate because of repeated failures or because of repeated customer complaints. Likewise, the Government may decrease the number of quality assurance inspections if performance dictates. The Government Contracting Officer shall make final determination of the validity of customer complaint(s).\n\n(3) If any of the services do not conform to contract requirements, the Government may require the Contractor to perform the services again in conformity with contract requirements, at no increase in contract amount. When the defects in services cannot be corrected by re-performance, the Government may require the Contractor to take necessary action to ensure that future performance conforms to contract requirements at no additional cost to the Government.\n\n17. Contract Security\nThe C&A requirements do not apply and a Security Accreditation Package is not required.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25526Q0611","place_of_performance":{"zip":"62959-1188","city":{"code":"46916","name":"Marion"},"state":{"code":"IL","name":"Illinois"},"street":"Department of Veterans Affairs Marion VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"Center 2401 West Main St."},"product_service_code":"J061"}],"due_at":"2026-08-20T12:00:00Z","due_date":"2026-08-20","closes_at":"2026-08-20T12:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","state":"IL","county":"17199","county_name":"Williamson County","city":"1746916","city_name":"Marion","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-25T00:32:56.537522Z","principal_notice_id":"a1012c163c7c45059bb5772afca8b089","description":{"text":"SOURCES SOUGHT NOTICE (Market Research Only)\nDepartment of Veterans Affairs (VA) NCO 15\nMarion VA Medical Center (VAMC), Marion, IL\nMedical Gas Alarm Cable Services\nTHIS IS NOT A SOLICITATION.\nThis Sources Sought Notice is issued solely for market research and planning purposes and does not constitute a solicitation or an obligation on the part of the Government to acquire any products or services. Responses will be treated as information only. The Government will not reimburse any costs associated with responding. Information received may be used by the Department of Veterans Affairs to inform the acquisition approach and performance specifications. Submission of pricing, capabilities, and other market data is permitted in accordance with FAR 15.201(e).\n1. PURPOSE\nThe Department of Veterans Affairs (VA), NCO 15, is conducting market research in accordance with FAR Part 10 to identify capable and interested sources for services to repair and replace deficient medical-gas alarm cabling and integrate identified CO2 alarm(s) with the designated master alarm station at the Marion VAMC. Responses will help the Government finalize the Statement of Work (SOW), determine the acquisition strategy (including small-business considerations), and assess industry capability. The Government may not answer vendor questions at this time.\n2. NAICS & BUSINESS INFORMATION\nNAICS Code: 238210 Electrical Contractors and Other Wiring Installation Contractors\nSBA Size Standard: $19.0 million (revenue).\nSocio economic status: Vendors shall indicate SDVOSB/VOSB (VetCert if applicable), WOSB, 8(a), HUBZone, Small/Large, etc.\n3. PLACE OF PERFORMANCE\nMarion VAMC\n2401 West Main Street\nMarion, Illinois\n4. REQUIREMENT SUMMARY\nThe VA Heartland Network 15 Contracting Office seeks a qualified contractor to furnish all labor, supervision, tools, equipment, materials, transportation, testing, documentation, and incidentals necessary to restore reliable, accurate, and identifiable alarm signaling for medical gas alarm circuits at the Marion VA Medical Center. Refer to the Statement of Work (SOW) which will follow this notice for additional details.\n5. REQUESTED VENDOR INFORMATION\nSubmit a capability statement (maximum 5 pages) including:\nCompany Name, Address, and Point of Contact (name, phone, email).\nUEI, CAGE, and Tax ID.\nBusiness size under NAICS 238210 and socio economic status (SDVOSB, VOSB, WOSB, 8(a), HUBZone, Small/Large).\nRelevant experience performing medical gas alarm repair/installation/integration in occupied healthcare facilities (include references).\nPersonnel qualifications/certifications (ASSE 6040/6010/6020/6030 as applicable) and any manufacturer training/authorization.\nApproach to cable repair/replacement, CO2 alarm integration, testing/commissioning, and measures to protect facility operations.\nApplicable contract vehicles (FSS, GSA, IDIQ, BPA) and contract numbers, if available.\n6. SUBMISSION INSTRUCTIONS\nResponses Due: Thursday, August 20, 2026 by 7:00 AM Central Time (CT)\nSubmission Method: Email PDF capability statement to: Erika M. Kobulnicky, Contract Specialist Erika.Kobulnicky@va.gov\nSubject Line: Sources Sought Response Medical Gas Alarm Cable Repair (Marion VAMC)\n7. ADDITIONAL INFORMATION\nThis notice shall not be construed as a commitment by the Government to issue a solicitation or award a contract, nor does it restrict the Government s acquisition approach. Based on responses, the Government may consider set asides for SDVOSBs, VOSBs, or another small business category; if inadequate small business response is received, alternate set asides or full and open competition may be considered in accordance with Public Law 109 461, Section 8127 (Veterans Benefits Act).\n8. IMPORTANT NOTES\nThis notice is for market research only and does not constitute a solicitation.\nThe Government may not respond to questions at this time; vendors should submit capability statements based on this notice.\nProprietary information must be clearly marked.\nNo telephone inquiries will be accepted.\nThe Statement of Work (SOW) will follow this notice and is subject to change based on market research and internal review.\n9. STATEMENT OF WORK (TO FOLLOW)\nThe SOW may be revised based on market research feedback.\nStatement of Work\nMedical Gas Alarm Cable Services\n1. Purpose\nThe Department of Veterans Affairs (VA), Marion VA Medical Center (VAMC), requires repair and replacement of deficient medical-gas alarm cabling and integration of identified CO2 alarm(s) with the designated master alarm station. The work is required to restore reliable, accurate, and identifiable alarm signaling for the affected medical-gas alarm circuits.\n2. Scope and Required Outcome\nThe contractor shall furnish all management, labor, supervision, tools, equipment, materials, transportation, testing, documentation, and incidentals necessary to complete the work described in this SOW, except for Government-furnished information expressly identified in Section 6.\nThe completed work shall provide the following outcomes:\nCorrect and reliable alarm communication between the identified originating locations and the designated master alarm station.\nCorrect alarm identification, alarm activation, normal condition, and restoration indication for every affected circuit.\nCable routing, termination, labeling, testing, and documentation that are compatible with the existing medical-gas alarm system, applicable codes and standards, manufacturer instructions, and VA facility requirements.\nA safe, operational, tested, documented, and VA-accepted system no later than 45 calendar days after the notice to proceed (NTP).\n3. Locations of Work\nWork will occur at the Marion VAMC, 2401 West Main Street, Marion, Illinois, including the following known locations:\nBuilding 2, electrical room G115, outside the Kitchen.\nBuilding 42, mechanical room A109.\nBuilding 2, Room 245.\nBuilding 42, Emergency Department Medical Service Area (ED MSA) office/master alarm-panel location.\nBefore starting work, the contractor shall conduct a site survey with the VA-designated representative to verify access, cable pathways, alarm-panel locations, cable endpoints, circuit identification, and existing conditions. The contractor shall promptly notify the COR in writing of site conditions that conflict with this SOW or prevent compliant performance.\n4. Technical Requirements\n4.1 Existing cable repair/replacement\nThe contractor shall:\nIdentify the affected existing medical-gas alarm cable connections and correct compromised, spliced, extended, improperly routed, mixed-up, or otherwise deficient connections within the defined work area.\nFurnish and install one 16-pair cable assembly, or other cable configuration approved in writing by the COR after field verification, between electrical room G115 in Building 2 and mechanical room A109 in Building 42.\nVerify the cable type, conductor size, shielding, listing, pathway, and terminations required for compatibility with the existing alarm equipment before procuring material. Materials shall be new and compatible with the existing system and manufacturer requirements.\nRoute cable in an approved pathway and protect it from physical damage. The contractor shall not use unapproved pathways or penetrate fire/smoke barriers without VA approval and required firestopping.\nTerminate, identify, and label cables at both endpoints. Labels shall correspond to the approved cable schedule and affected alarm point(s).\n\n4.2 CO2 master alarm connection\nThe contractor shall:\nFurnish and install cable between Building 2, Room 245, and the designated master panel in the Building 42 ED MSA office.\nVerify the precise endpoint, signal type, alarm-panel compatibility, and required cable characteristics during the pre-work survey.\nTerminate, identify, and label the cable at both endpoints.\nConnect and commission the identified CO2 alarm(s) so that the required alarm condition, normal condition, and restoration indication are accurately displayed at the designated master panel.\n\n4.3 Work plan and outages\nAt least 10 calendar days after NTP, and before beginning field work, the contractor shall submit a work plan to the COR for review. The plan shall include the proposed schedule, site access requirements, cable routes, affected equipment/circuits, anticipated shutdowns or alarm impairments, protective measures, testing sequence, and contingency/restoration procedures.\nThe contractor shall not begin work that may impair an alarm circuit, medical-gas alarm indication, or related facility operation until the VA-designated representative has approved the work window and required coordination. The contractor shall immediately notify the COR and VA-designated representative of an unintended alarm impairment, malfunction, or unsafe condition and shall take prompt action to restore the affected system.\n\n5. Standards, Safety, and Contractor Qualifications\n5.1 Applicable Requirements\nThe contractor shall comply with all applicable Federal, state, local, VA, facility, manufacturer, and code requirements, including the edition of NFPA 99 adopted or otherwise specified by the VA facility for this project.\nThe contractor shall comply with all VA facility requirements for medical-gas alarm impairments, permit-to-work procedures, infection-control measures, life-safety, firestopping, access, safety, and emergency restoration.\n\n5.2 Contractor Experience\nThe contractor shall demonstrate a minimum of three years of successful experience performing medical-gas alarm repair, installation, troubleshooting, testing, or commissioning in occupied healthcare facilities.\nBefore beginning work, the contractor shall submit three references for completed projects of similar scope and complexity. Each reference shall include:\nFacility name and location.\nDescription of the medical-gas alarm work performed.\nContract or project completion date.\nCustomer point of contact, telephone number, and email address.\nIdentification of whether the work included alarm cabling, alarm-panel integration, troubleshooting, testing, commissioning, or system restoration.\n\n5.3 Personnel Qualifications\nThe contractor shall provide qualified personnel with demonstrated experience in medical-gas alarm systems, low-voltage control wiring, cable termination, alarm-panel troubleshooting, functional testing, and commissioning.\nBefore beginning field work, the contractor shall submit the following for the project manager and each technician assigned to perform work:\nResume or work history showing relevant medical-gas alarm and healthcare-facility experience.\nApplicable state or local electrical license, if required by the jurisdiction for the work being performed.\nCurrent training certificates, professional credentials, and medical-gas qualifications applicable to the assigned work.\nDocumentation of manufacturer training, manufacturer authorization, or equivalent demonstrated competence for the existing medical-gas alarm equipment to be serviced.\n\nTechnicians performing maintenance, troubleshooting, testing, repair, or commissioning of medical-gas alarm equipment shall possess ASSE 6040 Medical Gas Systems Maintenance Personnel certification, or alternate written qualifications accepted by the VA medical-gas Responsible Facility Authority (RFA) before field work begins.\n\nIf the scope includes installation or modification of medical-gas-system components beyond alarm cabling and panel connections, including piping, outlets, valves, sensors connected to the pipeline system, or source equipment, personnel performing that installation work shall meet ASSE 6010 Medical Gas Systems Installer requirements.\n\nIf the VA RFA determines that inspection or independent verification is required, inspection and/or verification shall be performed by qualified ASSE 6020 Medical Gas Systems Inspector and/or ASSE 6030 Medical Gas Systems Verifier personnel, as applicable. The verifier shall be independent of the contractor performing the installation or repair work.\n\n5.4 Medical-Gas Coordination\nBefore beginning any work that may affect alarm function, medical-gas alarm indications, or facility operations, the contractor shall coordinate with the COR and the VA-designated Engineering Service and medical-gas RFA representative.\nThe contractor shall submit a written work plan for VA review before beginning field work. At a minimum, the work plan shall identify:\nAffected alarm panels, circuits, alarm points, and cable routes.\nProposed work sequence and work schedule.\nPlanned alarm impairments, shutdowns, or temporary monitoring measures.\nMeasures to protect patient safety and maintain facility operations.\nTesting and restoration procedures.\nEmergency contacts and contingency actions for an unplanned alarm-system malfunction or impairment.\nThe contractor shall not impair, disconnect, alter, or place out of service an alarm circuit without prior coordination and approval through the VA facility s applicable impairment and permit-to-work process.\n\n5.5 Safety and Protection of Government Property\nThe contractor shall secure tools and equipment at all times. Tools and equipment shall be removed from open areas or placed in an approved secured location during breaks, at the end of each workday, and whenever not in active use.\nThe contractor shall remove debris from the facility at the end of each workday and upon completion of the work. The contractor shall protect Government property and repair, at no additional cost to the Government and subject to VA approval, damage caused by the contractor or its employees.\nSmoking is prohibited on VAMC property.\n\n6. Government-Furnished Information and Coordination\nThe Government will provide reasonable access to the work locations and available existing system information, including available drawings, panel information, and known circuit information. The Government will identify the COR and the appropriate Engineering/medical-gas representative for coordination.\nThe contractor shall not rely on incomplete or unavailable drawings as a basis to omit necessary site verification. The contractor shall document field-verified conditions and proposed deviations from the approved plan for COR review before implementing a deviation.\n\n7. Submittals and Deliverables\nThe contractor shall provide the following to the COR:\nDeliverable\nDue date\nPersonnel qualifications/certifications, as applicable\nBefore beginning field work\nSite-survey findings, cable schedule, and proposed routing\nBefore installation\nWork plan, schedule, and outage/impairment plan\nWithin 10 calendar days after NTP and before field work\nProduct data for proposed cable, terminations, and related materials\nBefore installation\nDaily status report while an alarm circuit is impaired, if applicable\nBy the end of each affected workday\nSigned functional test report for every affected circuit/alarm point\nAt completion of testing\nMarked-up as-built drawing and final cable schedule identifying routes, endpoints, terminations, labels, and approved deviations\nBefore final acceptance\nWarranty information and closeout package\nBefore final acceptance\n\n8. Testing, Inspection, and Acceptance\nThe contractor shall coordinate all testing with the COR and VA-designated Engineering/medical-gas representative. The contractor shall provide all test equipment and personnel required for contractor testing.\nFor each affected circuit and alarm point, the contractor shall test and document, at a minimum:\nContinuity and correct point-to-point termination.\nCorrect alarm activation and identification at the designated master alarm station.\nNormal-condition indication after testing.\nCorrect restoration indication following simulated alarm activation.\nProper labeling and correlation of field labels, panel labels, cable schedule, and as-built documentation.\n\nThe work is acceptable only when all of the following are complete:\nEach affected alarm point operates correctly and communicates the correct status and identification to the designated master panel.\nAll cable routing, terminations, labels, and protective measures comply with the approved work plan, applicable requirements, and manufacturer instructions.\nRequired test records and closeout deliverables have been submitted and are complete.\nVA has completed final inspection and provided written acceptance through the COR or other authorized VA official.\nThe contractor shall correct deficiencies identified during testing or inspection at no additional cost to the Government and retest the corrected work.\n\n9. Period and Place of Performance\nThe period of performance is 45 calendar days after NTP. The place of performance is the Marion VAMC, 2401 West Main Street, Marion, Illinois, at the locations identified in Section 3 and any approved associated access pathways within the facility.\n\n10. Payment\nPayment terms and contract line item structure will be established in the solicitation and resulting contract. Final payment is contingent on completion and Government acceptance of all required work and deliverables.\n\n11. Contract Administration\nThe COR may monitor performance and inspect deliverables but may not authorize changes to contract scope, price, period of performance, or other contract terms. Only the Contracting Officer may make such changes in writing.\nAll contract administration functions will be retained by the Department of Veterans Affairs.\nThe Contracting Officer will be the only person authorized to approve changes or modify any of\nthe requirements under this contract. The Contractor shall communicate with the Contracting\nOfficer on all matters pertaining to contract administration. Only the Contracting Officer will be\nauthorized to make commitments or issue changes that affect price, quantity, or quality of\nperformance of this contract. In the event the Contractor effects any such change at the direction of any person other than the Contracting Officer, the change shall be considered unauthorized and no adjustment will be made in the contract price to cover any increase in costs incurred as a result thereof.\n\n12. Contracting Officer s Representative\nPursuant to VAAR Provision 852.270-1, Representatives of Contracting Officer, the\ndesignated representative for this contract will be determined at award.\n\n13. Acronyms and Definitions\nCDR: Contract Discrepancy Report. Report issued by the Government to the contractor to\ndocument a supply or service found to be unacceptable during contract performance.\nCLIN: Contract Line-Item Number. Unit of work (or service) to be performed (or delivered) by the contractor as a pay item.\nCO: Contracting Officer. A person with the authority to enter into, administer, and/or terminate\ncontracts and make related determinations and findings.\nCOR: Contracting Officer s Representative. An individual, including a Contracting Officer s\nRepresentative (COR), designated and authorized in writing by the contracting officer to perform\nspecific technical or administrative functions.\nQA: Quality Assurance. Actions taken by the government to assure contracted services meet PWS requirements.\n\n14. Personnel\nNon-Personal Services\nThis is a non-personal services contract. Personnel rendering services under this contract are not subject either by the contract s terms or by the manner of its administration, to the supervision and control usually prevailing in relationships between the government and its employees. The Government shall not exercise any supervision or control over the contract service s performing services herein. Such contract service s shall be accountable solely to the Contractor who, in turn, is responsible to the Government. Contractor Compliance with the Immigration and Nationality Act of 1952 The Contractor shall comply with any and all legal provisions contained in the Immigration and Nationality Act of 1952, As Amended; its related laws and regulations that are enforced by Homeland Security, Immigration and Customs Enforcement and the U.S Department of Labor as these may relate to non-immigrant foreign nationals working under contract or subcontract for the Contractor while providing services to Department of Veterans Affairs patient referrals.\n\n15. Hours of Operations\nBusiness hours for the VAMC follow:\na. Administrative hours: Monday through Friday, 8:00 a.m. - 4:30 p.m.\nb. National Holidays: The 11 holidays observed by the Federal Government are:\nNew Year s Day;\nMartin Luther King s Birthday;\nPresidents Day;\nMemorial Day;\nJuneteenth Independence Day\nIndependence Day;\nLabor Day;\nColumbus Day;\nVeterans Day;\nThanksgiving;\nChristmas; and any other day specifically declared by the President of the United States to be a national holiday.\nc. Off-Duty hours: Friday through Monday, 4:30 p.m. - 8:00 a.m.; Monday through Thursday, 4:30 pm 8:00 am.\n\n16. Quality Control\nCONTRACT PERFORMANCE MONITORING. The COR may perform surveillance of\nservices by any of the methods listed below:\na. Observing actual performance;\nb. Inspecting the services to determine whether or not the performance meets the performance standards; and\nc. Review of any other appropriate records.\n\n(1) When unacceptable performance occurs, the COR shall inform the Contractor and the Contracting Officer. This will normally be in writing unless circumstances necessitate verbal communication. In any case the COR shall document the discussion and place it in the COR file.\nWhen the COR determines formal written communication is required, the COR shall prepare a Contract Discrepancy Report (CDR) and present it to the contractor program manager. The Contractor shall acknowledge receipt of the CDR in writing. The CDR will specify if the Contractor is required to prepare a corrective action plan to document how the Contractor shall correct the unacceptable performance and avoid a recurrence. The CDR will also state how long after receipt the Contractor has to present this corrective action plan to the COR. The Government shall review the Contractor corrective action plan to determine acceptability. Any CDRs may become a part of the supporting documentation for any contractual action deemed necessary by the Contracting Officer.\n\n(2) Pursuant to VAAR Provision 852.270-1, Representatives of Contracting Officer\nrepresentative(s); The Government shall periodically evaluate the Contractor performance by appointing a Contracting Officers Representative (COR) to monitor performance to ensure services are received. The Government representative(s) shall evaluate the Contractor performance through inspections of observations, inspection of services or any other form of documentation and all complaints from VA personnel. The Government may inspect as each task is completed or increase the number of quality assurance inspections if deemed appropriate because of repeated failures or because of repeated customer complaints. Likewise, the Government may decrease the number of quality assurance inspections if performance dictates. The Government Contracting Officer shall make final determination of the validity of customer complaint(s).\n\n(3) If any of the services do not conform to contract requirements, the Government may require the Contractor to perform the services again in conformity with contract requirements, at no increase in contract amount. When the defects in services cannot be corrected by re-performance, the Government may require the Contractor to take necessary action to ensure that future performance conforms to contract requirements at no additional cost to the Government.\n\n17. Contract Security\nThe C&A requirements do not apply and a Security Accreditation Package is not required.","html":"SOURCES SOUGHT NOTICE (Market Research Only)\nDepartment of Veterans Affairs (VA)   NCO 15\nMarion VA Medical Center (VAMC), Marion, IL\nMedical Gas Alarm Cable Services\nTHIS IS NOT A SOLICITATION.\nThis Sources Sought Notice is issued solely for market research and planning purposes and does not constitute a solicitation or an obligation on the part of the Government to acquire any products or services. Responses will be treated as information only. The Government will not reimburse any costs associated with responding. Information received may be used by the Department of Veterans Affairs to inform the acquisition approach and performance specifications. Submission of pricing, capabilities, and other market data is permitted in accordance with FAR 15.201(e).\n1. PURPOSE\nThe Department of Veterans Affairs (VA), NCO 15, is conducting market research in accordance with FAR Part 10 to identify capable and interested sources for services to repair and replace deficient medical-gas alarm cabling and integrate identified CO2 alarm(s) with the designated master alarm station at the Marion VAMC. Responses will help the Government finalize the Statement of Work (SOW), determine the acquisition strategy (including small-business considerations), and assess industry capability. The Government may not answer vendor questions at this time.\n2. NAICS & BUSINESS INFORMATION\nNAICS Code: 238210   Electrical Contractors and Other Wiring Installation Contractors\nSBA Size Standard: $19.0 million (revenue).\nSocio economic status: Vendors shall indicate SDVOSB/VOSB (VetCert if applicable), WOSB, 8(a), HUBZone, Small/Large, etc.\n3. PLACE OF PERFORMANCE\nMarion VAMC\n2401 West Main Street\nMarion, Illinois\n4. REQUIREMENT SUMMARY\nThe VA Heartland Network 15 Contracting Office seeks a qualified contractor to furnish all labor, supervision, tools, equipment, materials, transportation, testing, documentation, and incidentals necessary to restore reliable, accurate, and identifiable alarm signaling for medical gas alarm circuits at the Marion VA Medical Center. Refer to the Statement of Work (SOW) which will follow this notice for additional details.\n5. REQUESTED VENDOR INFORMATION\nSubmit a capability statement (maximum 5 pages) including:\n  Company Name, Address, and Point of Contact (name, phone, email).\n  UEI, CAGE, and Tax ID.\n  Business size under NAICS 238210 and socio economic status (SDVOSB, VOSB, WOSB, 8(a), HUBZone, Small/Large).\n  Relevant experience performing medical gas alarm repair/installation/integration in occupied healthcare facilities (include references).\n  Personnel qualifications/certifications (ASSE 6040/6010/6020/6030 as applicable) and any manufacturer training/authorization.\n  Approach to cable repair/replacement, CO2 alarm integration, testing/commissioning, and measures to protect facility operations.\n  Applicable contract vehicles (FSS, GSA, IDIQ, BPA) and contract numbers, if available.\n6. SUBMISSION INSTRUCTIONS\nResponses Due: Thursday, August 20, 2026 by 7:00 AM Central Time (CT)\nSubmission Method: Email PDF capability statement to: Erika M. Kobulnicky, Contract Specialist   Erika.Kobulnicky@va.gov\nSubject Line:  Sources Sought Response   Medical Gas Alarm Cable Repair (Marion VAMC) \n7. ADDITIONAL INFORMATION\nThis notice shall not be construed as a commitment by the Government to issue a solicitation or award a contract, nor does it restrict the Government s acquisition approach. Based on responses, the Government may consider set asides for SDVOSBs, VOSBs, or another small business category; if inadequate small business response is received, alternate set asides or full and open competition may be considered in accordance with Public Law 109 461, Section 8127 (Veterans Benefits Act).\n8. IMPORTANT NOTES\n  This notice is for market research only and does not constitute a solicitation.\n  The Government may not respond to questions at this time; vendors should submit capability statements based on this notice.\n  Proprietary information must be clearly marked.\n  No telephone inquiries will be accepted.\n  The Statement of Work (SOW) will follow this notice and is subject to change based on market research and internal review.\n9. STATEMENT OF WORK (TO FOLLOW)\nThe SOW may be revised based on market research feedback.\nStatement of Work\nMedical Gas Alarm Cable Services\n1. Purpose\nThe Department of Veterans Affairs (VA), Marion VA Medical Center (VAMC), requires repair and replacement of deficient medical-gas alarm cabling and integration of identified CO2 alarm(s) with the designated master alarm station. The work is required to restore reliable, accurate, and identifiable alarm signaling for the affected medical-gas alarm circuits.\n2. Scope and Required Outcome\nThe contractor shall furnish all management, labor, supervision, tools, equipment, materials, transportation, testing, documentation, and incidentals necessary to complete the work described in this SOW, except for Government-furnished information expressly identified in Section 6.\nThe completed work shall provide the following outcomes:\nCorrect and reliable alarm communication between the identified originating locations and the designated master alarm station.\nCorrect alarm identification, alarm activation, normal condition, and restoration indication for every affected circuit.\nCable routing, termination, labeling, testing, and documentation that are compatible with the existing medical-gas alarm system, applicable codes and standards, manufacturer instructions, and VA facility requirements.\nA safe, operational, tested, documented, and VA-accepted system no later than 45 calendar days after the notice to proceed (NTP).\n3. Locations of Work\nWork will occur at the Marion VAMC, 2401 West Main Street, Marion, Illinois, including the following known locations:\nBuilding 2, electrical room G115, outside the Kitchen.\nBuilding 42, mechanical room A109.\nBuilding 2, Room 245.\nBuilding 42, Emergency Department Medical Service Area (ED MSA) office/master alarm-panel location.\nBefore starting work, the contractor shall conduct a site survey with the VA-designated representative to verify access, cable pathways, alarm-panel locations, cable endpoints, circuit identification, and existing conditions. The contractor shall promptly notify the COR in writing of site conditions that conflict with this SOW or prevent compliant performance.\n4. Technical Requirements\n4.1 Existing cable repair/replacement\nThe contractor shall:\nIdentify the affected existing medical-gas alarm cable connections and correct compromised, spliced, extended, improperly routed, mixed-up, or otherwise deficient connections within the defined work area.\nFurnish and install one 16-pair cable assembly, or other cable configuration approved in writing by the COR after field verification, between electrical room G115 in Building 2 and mechanical room A109 in Building 42.\nVerify the cable type, conductor size, shielding, listing, pathway, and terminations required for compatibility with the existing alarm equipment before procuring material. Materials shall be new and compatible with the existing system and manufacturer requirements.\nRoute cable in an approved pathway and protect it from physical damage. The contractor shall not use unapproved pathways or penetrate fire/smoke barriers without VA approval and required firestopping.\nTerminate, identify, and label cables at both endpoints. Labels shall correspond to the approved cable schedule and affected alarm point(s).\n\n4.2 CO2 master alarm connection\nThe contractor shall:\nFurnish and install cable between Building 2, Room 245, and the designated master panel in the Building 42 ED MSA office.\nVerify the precise endpoint, signal type, alarm-panel compatibility, and required cable characteristics during the pre-work survey.\nTerminate, identify, and label the cable at both endpoints.\nConnect and commission the identified CO2 alarm(s) so that the required alarm condition, normal condition, and restoration indication are accurately displayed at the designated master panel.\n\n4.3 Work plan and outages\nAt least 10 calendar days after NTP, and before beginning field work, the contractor shall submit a work plan to the COR for review. The plan shall include the proposed schedule, site access requirements, cable routes, affected equipment/circuits, anticipated shutdowns or alarm impairments, protective measures, testing sequence, and contingency/restoration procedures.\nThe contractor shall not begin work that may impair an alarm circuit, medical-gas alarm indication, or related facility operation until the VA-designated representative has approved the work window and required coordination. The contractor shall immediately notify the COR and VA-designated representative of an unintended alarm impairment, malfunction, or unsafe condition and shall take prompt action to restore the affected system.\n\n5. Standards, Safety, and Contractor Qualifications\n5.1 Applicable Requirements\nThe contractor shall comply with all applicable Federal, state, local, VA, facility, manufacturer, and code requirements, including the edition of NFPA 99 adopted or otherwise specified by the VA facility for this project.\nThe contractor shall comply with all VA facility requirements for medical-gas alarm impairments, permit-to-work procedures, infection-control measures, life-safety, firestopping, access, safety, and emergency restoration.\n\n5.2 Contractor Experience\nThe contractor shall demonstrate a minimum of three years of successful experience performing medical-gas alarm repair, installation, troubleshooting, testing, or commissioning in occupied healthcare facilities.\nBefore beginning work, the contractor shall submit three references for completed projects of similar scope and complexity. Each reference shall include:\nFacility name and location.\nDescription of the medical-gas alarm work performed.\nContract or project completion date.\nCustomer point of contact, telephone number, and email address.\nIdentification of whether the work included alarm cabling, alarm-panel integration, troubleshooting, testing, commissioning, or system restoration.\n\n5.3 Personnel Qualifications\nThe contractor shall provide qualified personnel with demonstrated experience in medical-gas alarm systems, low-voltage control wiring, cable termination, alarm-panel troubleshooting, functional testing, and commissioning.\nBefore beginning field work, the contractor shall submit the following for the project manager and each technician assigned to perform work:\nResume or work history showing relevant medical-gas alarm and healthcare-facility experience.\nApplicable state or local electrical license, if required by the jurisdiction for the work being performed.\nCurrent training certificates, professional credentials, and medical-gas qualifications applicable to the assigned work.\nDocumentation of manufacturer training, manufacturer authorization, or equivalent demonstrated competence for the existing medical-gas alarm equipment to be serviced.\n\nTechnicians performing maintenance, troubleshooting, testing, repair, or commissioning of medical-gas alarm equipment shall possess ASSE 6040 Medical Gas Systems Maintenance Personnel certification, or alternate written qualifications accepted by the VA medical-gas Responsible Facility Authority (RFA) before field work begins.\n\nIf the scope includes installation or modification of medical-gas-system components beyond alarm cabling and panel connections, including piping, outlets, valves, sensors connected to the pipeline system, or source equipment, personnel performing that installation work shall meet ASSE 6010 Medical Gas Systems Installer requirements.\n\nIf the VA RFA determines that inspection or independent verification is required, inspection and/or verification shall be performed by qualified ASSE 6020 Medical Gas Systems Inspector and/or ASSE 6030 Medical Gas Systems Verifier personnel, as applicable. The verifier shall be independent of the contractor performing the installation or repair work.\n\n5.4 Medical-Gas Coordination\nBefore beginning any work that may affect alarm function, medical-gas alarm indications, or facility operations, the contractor shall coordinate with the COR and the VA-designated Engineering Service and medical-gas RFA representative.\nThe contractor shall submit a written work plan for VA review before beginning field work. At a minimum, the work plan shall identify:\nAffected alarm panels, circuits, alarm points, and cable routes.\nProposed work sequence and work schedule.\nPlanned alarm impairments, shutdowns, or temporary monitoring measures.\nMeasures to protect patient safety and maintain facility operations.\nTesting and restoration procedures.\nEmergency contacts and contingency actions for an unplanned alarm-system malfunction or impairment.\nThe contractor shall not impair, disconnect, alter, or place out of service an alarm circuit without prior coordination and approval through the VA facility s applicable impairment and permit-to-work process.\n\n5.5 Safety and Protection of Government Property\nThe contractor shall secure tools and equipment at all times. Tools and equipment shall be removed from open areas or placed in an approved secured location during breaks, at the end of each workday, and whenever not in active use.\nThe contractor shall remove debris from the facility at the end of each workday and upon completion of the work. The contractor shall protect Government property and repair, at no additional cost to the Government and subject to VA approval, damage caused by the contractor or its employees.\nSmoking is prohibited on VAMC property.\n\n6. Government-Furnished Information and Coordination\nThe Government will provide reasonable access to the work locations and available existing system information, including available drawings, panel information, and known circuit information. The Government will identify the COR and the appropriate Engineering/medical-gas representative for coordination.\nThe contractor shall not rely on incomplete or unavailable drawings as a basis to omit necessary site verification. The contractor shall document field-verified conditions and proposed deviations from the approved plan for COR review before implementing a deviation.\n\n7. Submittals and Deliverables\nThe contractor shall provide the following to the COR:\nDeliverable\nDue date\nPersonnel qualifications/certifications, as applicable\nBefore beginning field work\nSite-survey findings, cable schedule, and proposed routing\nBefore installation\nWork plan, schedule, and outage/impairment plan\nWithin 10 calendar days after NTP and before field work\nProduct data for proposed cable, terminations, and related materials\nBefore installation\nDaily status report while an alarm circuit is impaired, if applicable\nBy the end of each affected workday\nSigned functional test report for every affected circuit/alarm point\nAt completion of testing\nMarked-up as-built drawing and final cable schedule identifying routes, endpoints, terminations, labels, and approved deviations\nBefore final acceptance\nWarranty information and closeout package\nBefore final acceptance\n\n8. Testing, Inspection, and Acceptance\nThe contractor shall coordinate all testing with the COR and VA-designated Engineering/medical-gas representative. The contractor shall provide all test equipment and personnel required for contractor testing.\nFor each affected circuit and alarm point, the contractor shall test and document, at a minimum:\nContinuity and correct point-to-point termination.\nCorrect alarm activation and identification at the designated master alarm station.\nNormal-condition indication after testing.\nCorrect restoration indication following simulated alarm activation.\nProper labeling and correlation of field labels, panel labels, cable schedule, and as-built documentation.\n\nThe work is acceptable only when all of the following are complete:\nEach affected alarm point operates correctly and communicates the correct status and identification to the designated master panel.\nAll cable routing, terminations, labels, and protective measures comply with the approved work plan, applicable requirements, and manufacturer instructions.\nRequired test records and closeout deliverables have been submitted and are complete.\nVA has completed final inspection and provided written acceptance through the COR or other authorized VA official.\nThe contractor shall correct deficiencies identified during testing or inspection at no additional cost to the Government and retest the corrected work.\n\n9. Period and Place of Performance\nThe period of performance is 45 calendar days after NTP. The place of performance is the Marion VAMC, 2401 West Main Street, Marion, Illinois, at the locations identified in Section 3 and any approved associated access pathways within the facility.\n\n10. Payment\nPayment terms and contract line item structure will be established in the solicitation and resulting contract. Final payment is contingent on completion and Government acceptance of all required work and deliverables.\n\n11. Contract Administration\nThe COR may monitor performance and inspect deliverables but may not authorize changes to contract scope, price, period of performance, or other contract terms. Only the Contracting Officer may make such changes in writing.\nAll contract administration functions will be retained by the Department of Veterans Affairs.\nThe Contracting Officer will be the only person authorized to approve changes or modify any of\nthe requirements under this contract. The Contractor shall communicate with the Contracting\nOfficer on all matters pertaining to contract administration. Only the Contracting Officer will be\nauthorized to make commitments or issue changes that affect price, quantity, or quality of\nperformance of this contract. In the event the Contractor effects any such change at the direction of any person other than the Contracting Officer, the change shall be considered unauthorized and no adjustment will be made in the contract price to cover any increase in costs incurred as a result thereof.\n\n 12. Contracting Officer s Representative\n Pursuant to VAAR Provision 852.270-1, Representatives of Contracting Officer, the\ndesignated representative for this contract will be determined at award.\n\n13. Acronyms and Definitions\nCDR: Contract Discrepancy Report. Report issued by the Government to the contractor to\ndocument a supply or service found to be unacceptable during contract performance.\nCLIN: Contract Line-Item Number. Unit of work (or service) to be performed (or delivered) by the contractor as a pay item.\nCO: Contracting Officer. A person with the authority to enter into, administer, and/or terminate\ncontracts and make related determinations and findings.\nCOR: Contracting Officer s Representative. An individual, including a Contracting Officer s\nRepresentative (COR), designated and authorized in writing by the contracting officer to perform\nspecific technical or administrative functions.\nQA: Quality Assurance. Actions taken by the government to assure contracted services meet PWS requirements.\n\n14. Personnel\nNon-Personal Services\nThis is a non-personal services contract. Personnel rendering services under this contract are not subject either by the contract s terms or by the manner of its administration, to the supervision and control usually prevailing in relationships between the government and its employees. The Government shall not exercise any supervision or control over the contract service s performing services herein. Such contract service s shall be accountable solely to the Contractor who, in turn, is responsible to the Government. Contractor Compliance with the Immigration and Nationality Act of 1952 The Contractor shall comply with any and all legal provisions contained in the Immigration and Nationality Act of 1952, As Amended; its related laws and regulations that are enforced by Homeland Security, Immigration and Customs Enforcement and the U.S Department of Labor as these may relate to non-immigrant foreign nationals working under contract or subcontract for the Contractor while providing services to Department of Veterans Affairs patient referrals.\n\n15. Hours of Operations\nBusiness hours for the VAMC follow:\na. Administrative hours: Monday through Friday, 8:00 a.m. - 4:30 p.m.\nb. National Holidays: The 11 holidays observed by the Federal Government are:\nNew Year s Day;\nMartin Luther King s Birthday;\nPresidents Day;\nMemorial Day;\nJuneteenth Independence Day\nIndependence Day;\nLabor Day;\nColumbus Day;\nVeterans Day;\nThanksgiving;\nChristmas; and any other day specifically declared by the President of the United States to be a national holiday.\nc. Off-Duty hours: Friday through Monday, 4:30 p.m. - 8:00 a.m.; Monday through Thursday, 4:30 pm   8:00 am.\n\n16. Quality Control\nCONTRACT PERFORMANCE MONITORING. The COR may perform surveillance of\nservices by any of the methods listed below:\na.  Observing actual performance;\nb.  Inspecting the services to determine whether or not the performance meets the performance standards; and\nc.  Review of any other appropriate records.\n\n(1) When unacceptable performance occurs, the COR shall inform the Contractor and the Contracting Officer. This will normally be in writing unless circumstances necessitate verbal communication. In any case the COR shall document the discussion and place it in the COR file.\nWhen the COR determines formal written communication is required, the COR shall prepare a Contract Discrepancy Report (CDR) and present it to the contractor program manager. The Contractor shall acknowledge receipt of the CDR in writing. The CDR will specify if the Contractor is required to prepare a corrective action plan to document how the Contractor shall correct the unacceptable performance and avoid a recurrence. The CDR will also state how long after receipt the Contractor has to present this corrective action plan to the COR. The Government shall review the Contractor corrective action plan to determine acceptability. Any CDRs may become a part of the supporting documentation for any contractual action deemed necessary by the Contracting Officer.\n\n(2) Pursuant to VAAR Provision 852.270-1, Representatives of Contracting Officer\nrepresentative(s); The Government shall periodically evaluate the Contractor performance by appointing a Contracting Officers Representative (COR) to monitor performance to ensure services are received. The Government representative(s) shall evaluate the Contractor performance through inspections of observations, inspection of services or any other form of documentation and all complaints from VA personnel. The Government may inspect as each task is completed or increase the number of quality assurance inspections if deemed appropriate because of repeated failures or because of repeated customer complaints. Likewise, the Government may decrease the number of quality assurance inspections if performance dictates. The Government Contracting Officer shall make final determination of the validity of customer complaint(s).\n\n(3) If any of the services do not conform to contract requirements, the Government may require the Contractor to perform the services again in conformity with contract requirements, at no increase in contract amount. When the defects in services cannot be corrected by re-performance, the Government may require the Contractor to take necessary action to ensure that future performance conforms to contract requirements at no additional cost to the Government.\n\n17. Contract Security\nThe C&A requirements do not apply and a Security Accreditation Package is not required.","origin":"detail"},"contacts":[{"name":"Erika Kobulnicky","role":"primary","email":"Erika.Kobulnicky@va.gov","phone":"913-946-1991","title":"Contract Specialist"}],"place_of_performance":{"zip":"62959-1188","city":{"code":"46916","name":"Marion"},"state":{"code":"IL","name":"Illinois"},"street":"Department of Veterans Affairs Marion VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"Center 2401 West Main St."},"office_address":{"zip":"66048","city":"LEAVENWORTH","state":"KS","country":"USA"},"naics_codes":["238210"],"award":{"awardee":{}},"attachments":[{"resource_id":"103b998c31a84043a5174cef6d29335f","name":"va.gov","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2026-08-14T19:25:13.509Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov/marion-health-care/","mirrored":false}],"awards":[],"related":[{"key":"36C25527R0016","latest_notice_id":"a7eee67b427c47158525b1a79fc8ecd2","title":"Z2DA--657-24-102JC - Prepare Site for New PET/CT, Room A011D (MD) FY27 NRM VISN Base, CON (VA-27-00017492) 657-27-1-8434-0001","solicitation_number":"36C25527R0016","notice_type":"p","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"236220","psc":"Z2DA","set_aside":"SDVOSBC","state":"MO","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"WORK: THE GENERAL DESCRIPTION: VA SAINT LOUIS HEALTH CARE SYSTEM","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C25526Q0617","latest_notice_id":"3506983a2af048deaf442eae0f8b8a04","title":"H112--Annual/Sem-i annual fire smoke inspections and auto door services l EKH","solicitation_number":"36C25526Q0617","notice_type":"o","first_type":"r","first_posted":"2026-08-19","last_posted":"2026-11-18","notices":11,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"541350","psc":"H112","set_aside":"SBA","state":"KS","county":"20103","county_name":"Leavenworth County","city":"2039000","city_name":"Leavenworth","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C25527Q0057","latest_notice_id":"fbd76a4c366d45e896674756383b4fb2","title":"C222--589-27-108, Correct Electrical Deficiencies in Building 26 KCVA (ME) FY27 NRM VISN Base - AE (VA-27-00021035)","solicitation_number":"36C25527Q0057","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":2,"due_at":"2026-12-01T20:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"541330","psc":"C222","set_aside":"EDWOSB","state":"MO","county":"29095","county_name":"Jackson County","city":"2938000","city_name":"Kansas City","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T09:15:14.204648Z"},{"key":"36C25527Q00571","latest_notice_id":"53c5d2376d9e4fb79d39a712a62deb10","title":"C222--589-27-108, Correct Electrical Deficiencies in Building 26 KCVA (ME) FY27 NRM VISN Base - AE (VA-27-00021035)","solicitation_number":"36C25527Q0057_1","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-12-01T20:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"541330","psc":"C222","set_aside":"SDVOSBC","state":"MO","county":"29095","county_name":"Jackson County","city":"2938000","city_name":"Kansas City","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C25527Q0053","latest_notice_id":"f87b14f3ce2643d69bdc633c0b05a712","title":"J065--Imaging Service & Maintenance EHCC & MTV","solicitation_number":"36C25527Q0053","notice_type":"o","first_type":"p","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":2,"due_at":"2026-12-02T14:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"811210","psc":"J065","set_aside":null,"state":"IN","county":"18163","county_name":"Vanderburgh County","city":"1822000","city_name":"Evansville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open":[{"key":"W912P627MR027755","latest_notice_id":"5cc099a662c74ba1a59532a34d6f03e2","title":"Commercial Gear Backup Power (CGBP) and Control System Improvements at Fish Barrier","solicitation_number":"W912P627MR027755","notice_type":"r","first_type":"r","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":"2026-12-02T19:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912P6","office_name":"W072 ENDIST CHICAGO","naics":"238210","psc":"Z2MZ","set_aside":null,"state":"IL","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_street","state_evidence":"ROMEOVILLE, IL","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"W912P627X1CZ7","latest_notice_id":"d13db3ad548f4e1cb0a6bc7bef73a313","title":"MARKET SURVEY SOURCES SOUGHT NOTICE FOR BARRIER IIB ATS SYSTEMS REPLACEMENT","solicitation_number":"W912P627X1CZ7","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-07T20:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912P6","office_name":"W072 ENDIST CHICAGO","naics":"238210","psc":"Z2BG","set_aside":null,"state":"IL","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_street","state_evidence":"790 EAST OLD ROMEO RD LOCKPORT/ROMEOVILLE, IL 60441","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C25027Q0014","latest_notice_id":"b13cc87179e947e7b42da2de44a6bde1","title":"J061--541 Electrical Power Distribution Equipment Testing, Inspection, and Maintenance - VAMC Cleveland","solicitation_number":"36C25027Q0014","notice_type":"k","first_type":"k","first_posted":"2026-10-09","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"238210","psc":"J061","set_aside":"SBA","state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":40,"indexable":false}