{"canonical":"https://sealedbidder.com/opportunities/36c25526q0584","key":"36C25526Q0584","url":"https://sealedbidder.com/opportunities/36c25526q0584","title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","solicitation_number":"36C25526Q0584","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-10-02T18:00:00Z","first_posted":"2026-08-04","last_posted":"2026-09-01","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"238210","psc":"J059","set_aside":"SBA","place_state":"KS","place_scope":"site","site":"Leavenworth VA Medical Center","place_state_source":null,"place_evidence":null,"place_county":"20103","place_county_name":"Leavenworth County","place_city":"2039000","place_city_name":"Leavenworth","winner":null,"award_amount":null,"publications":[{"notice_id":"0998fb8dabb446df9b5f2d2d828955fc","title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","solicitation_number":"36C25526Q0584","notice_type":"r","base_type":"r","posted":"2026-08-04","posted_at":"2026-08-04T20:28:07.323Z","due_at":"2026-08-11T18:00:00Z","due_date":"2026-08-11","cancelled":false,"archived":true,"archive_date":"2026-09-10","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/0998fb8dabb446df9b5f2d2d828955fc/view","enriched":true,"history":[{"index":5,"title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-04T20:28:07.323Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"0998fb8dabb446df9b5f2d2d828955fc","solicitation_number":"36C25526Q0584"},{"index":3,"title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-01T21:11:23.497Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"282a5419770a4285855fe228228701d5","solicitation_number":"36C25526Q0584","related_opportunity_id":"0998fb8dabb446df9b5f2d2d828955fc"},{"index":2,"title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-01T21:11:23.429Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"2ef7bf2cd79d471aaab4cca71038c75b","solicitation_number":"36C25526Q0584","related_opportunity_id":"0998fb8dabb446df9b5f2d2d828955fc"}]},{"notice_id":"27cde944097c4b5fbfbe38873994e3a7","title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","solicitation_number":"36C25526Q0584","notice_type":"r","base_type":"r","posted":"2026-08-04","posted_at":"2026-08-04T20:28:05.951Z","due_at":"2026-08-11T18:00:00Z","due_date":"2026-08-11","cancelled":false,"archived":true,"archive_date":"2026-09-10","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/27cde944097c4b5fbfbe38873994e3a7/view","enriched":true,"history":[{"index":3,"title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-04T20:28:05.951Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"27cde944097c4b5fbfbe38873994e3a7","solicitation_number":"36C25526Q0584"}]},{"notice_id":"282a5419770a4285855fe228228701d5","title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","solicitation_number":"36C25526Q0584","notice_type":"k","base_type":"r","posted":"2026-09-01","posted_at":"2026-09-01T21:11:23.497Z","due_at":"2026-10-02T18:00:00Z","due_date":"2026-10-02","cancelled":false,"archived":true,"archive_date":"2026-11-01","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/282a5419770a4285855fe228228701d5/view","enriched":true,"history":[{"index":5,"title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-10T14:15:06.183Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"7fb152917d8942399878b2b101f646d1","solicitation_number":"36C25526Q0584_0001","parent_opportunity_id":"282a5419770a4285855fe228228701d5","related_opportunity_id":"0998fb8dabb446df9b5f2d2d828955fc"},{"index":4,"title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-04T20:28:07.323Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"0998fb8dabb446df9b5f2d2d828955fc","solicitation_number":"36C25526Q0584"},{"index":2,"title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-01T21:11:23.497Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"282a5419770a4285855fe228228701d5","solicitation_number":"36C25526Q0584","related_opportunity_id":"0998fb8dabb446df9b5f2d2d828955fc"}]},{"notice_id":"2ef7bf2cd79d471aaab4cca71038c75b","title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","solicitation_number":"36C25526Q0584","notice_type":"k","base_type":"r","posted":"2026-09-01","posted_at":"2026-09-01T21:11:23.429Z","due_at":"2026-10-02T18:00:00Z","due_date":"2026-10-02","cancelled":false,"archived":true,"archive_date":"2026-11-01","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/2ef7bf2cd79d471aaab4cca71038c75b/view","enriched":true,"history":[{"index":4,"title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-04T20:28:07.323Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"0998fb8dabb446df9b5f2d2d828955fc","solicitation_number":"36C25526Q0584"},{"index":2,"title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-01T21:11:23.429Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"2ef7bf2cd79d471aaab4cca71038c75b","solicitation_number":"36C25526Q0584","related_opportunity_id":"0998fb8dabb446df9b5f2d2d828955fc"}]}],"latest_notice_id":"2ef7bf2cd79d471aaab4cca71038c75b","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-08-04","posted_at":"2026-08-04T20:28:07.323Z","created_at":"2026-08-04T20:28:05.142Z","modified_at":"2026-09-10T05:07:48.881Z","response_deadline":{"raw":"2026-08-11T13:00:00-05:00","utc":"2026-08-11T18:00:00Z","date":"2026-08-11","time":"13:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/0998fb8dabb446df9b5f2d2d828955fc/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","agency":{"office":{"code":"36C255","name":"255-NETWORK CONTRACT OFFICE 15 (36C255)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"66048","city":"LEAVENWORTH","state":"KS","country":"USA"},"organization_id":"100186523","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-09-10","archive_type":"auto_custom"},"history":[{"index":5,"title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-04T20:28:07.323Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"0998fb8dabb446df9b5f2d2d828955fc","solicitation_number":"36C25526Q0584"},{"index":3,"title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-01T21:11:23.497Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"282a5419770a4285855fe228228701d5","solicitation_number":"36C25526Q0584","related_opportunity_id":"0998fb8dabb446df9b5f2d2d828955fc"},{"index":2,"title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-01T21:11:23.429Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"2ef7bf2cd79d471aaab4cca71038c75b","solicitation_number":"36C25526Q0584","related_opportunity_id":"0998fb8dabb446df9b5f2d2d828955fc"}],"contacts":[{"name":"Maria Riza R. Owen","role":"primary","email":"maria.owen2@va.gov","phone":"913-946-1965","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"0998fb8dabb446df9b5f2d2d828955fc","lineage_id":"2ef7bf2cd79d471aaab4cca71038c75b","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-26T03:02:11.021690403Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"d6dafc27c243b9987349abb3b07ad219aa3c267f92f14d50fa73735516c8e607","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-26T03:02:11.021690403Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"Sources Sought Notice:\nThis is not a request for formal proposals or quotes, it does not obligate the Government to award a contract. Requests for a solicitation will not receive a response. Responses to this Sources Sought must be in writing. \nThe purpose of this Sources Sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potentially qualified businesses interested in and capable of providing the required services.  \nDocumentation of technical expertise must be presented in sufficient detail for the government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. \nResponses to this notice shall include the following: \n(a) company name \n(b) address \n(c) point of contact \n(d) phone and email\n(e) UEI number \n(f) Cage Code \n(g) Type of small business, e.g., Services Disabled Veteran Owned Small Business, Veteran-Owned Small Business, 8(a), HUBZone, Women Owned Small Business, Small Disadvantaged Business, Small Business, or Large Business; and \n(h) Capability statement that addresses the organization s qualifications and ability to perform as a contractor for the work described below.\nThis Sources Sought is for Dwight D. Eisenhower VA Medical Center, Leavenworth, Kansas who have a requirement for Automatic Transfer Switch (ATS) Inspection, Preventive Maintenance, Repair Services, and Isolation Power Panel Inspection.\nThe NAICS Code is 238210 with a Small Business size standard of $19 million. SDVOSB/VOSB vendors must be registered in the SBA VetCert database. \nOfferors capable of providing this service shall notify the Contract Specialist no later than (NLT) August 11, 2026, 1:00 pm CST via email at maria.owen2@va.gov\nAll information is to be submitted via email to: maria.owen2@va.gov. Phone calls will not be accepted.\n\n\nPerformance Work Statement \nAutomatic Transfer Switch (ATS) Inspection, Preventive Maintenance, Repair Services, and Isolation Power Panel Inspection\n1. Scope \nThe Department of Veterans Affairs requires a qualified contractor to provide all labor, materials, equipment, tools, supervision, transportation, and technical expertise necessary to perform inspections, testing, preventive maintenance, repairs, and emergency response services for Automatic Transfer Switches (ATS) and Isolation Electrical Power Panels throughout the Dwight D. Eisenhower VA Medical Center, 4101 S 4th Street, Leavenworth, KS 66048. All work shall ensure safe, reliable, and code compliant operation of all systems. \n\n2. Period of Performance\nOctober 1, 2026   September 30, 2031\n3. Performance Objectives\nThe contractor shall deliver the following outcomes:\n     3.1 ATS Systems\nEnsure all ATS units operate safely, reliably, and in accordance with NFPA standards and manufacturer specifications.\nMaintain full functionality of transfer and retransfer operations, voltage sensing, phase rotation, time delay functions, and ATS battery systems.\n      3.2 Isolation Power Panels\nEnsure proper operation of Line Isolation Monitors (LIMs) and electrical isolation systems per NFPA 99.\nMaintain accurate, clearly labeled circuits consistent with facility electrical drawings.\n     3.3 Emergency Repairs\nRestore system functionality rapidly for critical outages with minimal disruption to clinical operations.\n      3.4 Compliance & Safety\nEnsure all work complies with NFPA 70, NFPA 70B, NFPA 99, OSHA, VA standards, and manufacturer guidelines.\n4. Performance Requirements\n      4.1 ATS Inspection and Maintenance Tasks\nThe contractor shall perform and document the following measurable tasks:\nVisual inspection with photographic evidence.\nCleaning of enclosures using manufacturer approved methods.\nInfrared thermal scanning with image attachments.\nMeasurement and recording of temperature and torque values using calibrated instruments.\nOperational testing, documenting pass/fail for: \ntransfer\nretransfer\nvoltage sensing\ntime delay functions\nphase rotation\nATS battery testing where applicable (voltage, load test, specific gravity).\nLubrication of components using manufacturer specified lubricants.\nCoordinated generator functional testing, including recorded transfer and retransfer times.\n4.2 Isolation Panel Inspection and Testing Requirements\nThe contractor shall:\nProvide photographic documentation of panel inspections.\nTest LIMs, verify alarm set points, simulate faults, and document response times.\nPerform NFPA 99 compliant ground fault testing.\nMeasure voltage, current, and insulation resistance values.\nVerify labeling accuracy against electrical drawings.\nClean interiors with nonconductive tools and record methods.\nVerify torque values using calibrated instruments.\n5. Performance Standards\n\n6. Performance Monitoring (Government Surveillance)\nThe COR will evaluate contractor performance using the following methods:\nInspection of reports (routine & emergency) for accuracy and completeness.\nRandom onsite inspections of ATS and isolation panel systems.\nVerification of corrective action timelines.\nReview of emergency response logs.\n7. Deliverables\n      7.1 Routine Service Reports   Due within 48 hours\nReports shall include:\ndate/time of service\npersonnel names\nequipment inspected\nall measured values\nphotos and thermal images\npass/fail results\ndeficiencies and recommended corrective actions\nreferences to NFPA/manufacturer standards\n7.2 Emergency Repair Reports   Due within 24 hours\nInclude issue description, corrective actions, parts replaced, test results, and verification of restored operation.\n7.3 Annual Executive Summary   Due within 30 days\nProvide an overview of:\nsystem condition\nrecurring deficiencies\nreliability trends\nrecommended upgrades or corrective projects\n8. Contractor Qualifications\nContractor personnel shall:\nMaintain valid Kansas electrical licensing.\nHave documented experience with ATS and healthcare isolation power systems.\nComplete annual VA privacy, security, and safety training.\nPass VA background checks (VAAR 852.237 70).\nUse calibrated testing instruments.\nWear VA issued identification badges.\n9. Security & Safety Requirements\nContractor shall comply with:\nVA safety regulations\nOSHA regulations\nNFPA standards\nVA infection control procedures\n10. Non Conforming Performance\nFailure to perform may result in:\nNotice of Concern\nCorrective Action Request\nCure Notice in accordance with FAR 49.607\n\n11. List of Equipment\n\nAutomatic Transfer Switch List\nType\nCAT #\nSER #\nCUST DESIG\nASCO\nH07ATBB31200N5XM\n1329719-WE\nATS-4 122 Generator Shelter\nASCO\nJ07ATS30600C5XC\n2688889-001RE\nElevator ATS 88/89 SW GEAR\nZENITH\nZTS2L15FC-7\n1402776-1\nATS-4-EHC1A 91 North\nASCO\nJ07ATBB30400N5XC\n2564471-001WE\nATS-B91 01 91 North\nZENITH\nZTS000B00060E\n151048000-10-1\nATS-5-EHM1A 91 North\nZENITH\nZTS2L15FC-7\n1402776-2\nATS-3-GE-X-RAY 91 North\nZENITH\nZTS2L15EC-7\n1402847-2\nATS-1-EC1A 91 North\nZENITH\nZTS2L15EC-7\n1402847-1\nATS-2-EC21 91 North\nCUMMINS\nBTPCB-1500816\nB15M800254\nLift Station ATS Cemetery\nASCO\nG7AUBB31600C5XM\n1457708 WE\nATS 3 122 Platform\nASCO\nJ07ATBB30150C5XC\n1329727 WE\nATS-2 122 Sub-basement\nASCO\nJ07ATBB30600C5XC\n1329726 WE\nATS-1 122 Sub-basement\nASCO\nH07ATBB31200C5XC\n581676 WE\nBLD89_ATS-1 88/89\nZENITH\nZBTS00B10260F\n150163519-10-1\nChiller ATS-1 Bldg 161\nCUMMINS\nBTPCC-A073V586\nE23M241483\nPOWER HOUSE ATS\nASCO\nG07ATBB31600C5XC\n2731373-001WE\nBLD89 ATS-2 88/89\nASCO\nE0094003100095XC\n2443570-001WE\nDOM BLD 160\nASCO\nH07ATBA30800C5XC\n581679-FP\n91 ATS 1 91 South\n\n\n\n\n\n\n\nIsolation Panel Equipment\nItem #\nManufacturer\nPanel Type\nSerial Model\n1\nSquare D\nISO\n220525257\n2\nSquare D\nISO\n2201511637\n3\nSquare D\nISO\n2201524814\n4\nSquare D\nISO","text":"Sources Sought Notice:\nThis is not a request for formal proposals or quotes, it does not obligate the Government to award a contract. Requests for a solicitation will not receive a response. Responses to this Sources Sought must be in writing.\nThe purpose of this Sources Sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potentially qualified businesses interested in and capable of providing the required services.\nDocumentation of technical expertise must be presented in sufficient detail for the government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition.\nResponses to this notice shall include the following:\n(a) company name\n(b) address\n(c) point of contact\n(d) phone and email\n(e) UEI number\n(f) Cage Code\n(g) Type of small business, e.g., Services Disabled Veteran Owned Small Business, Veteran-Owned Small Business, 8(a), HUBZone, Women Owned Small Business, Small Disadvantaged Business, Small Business, or Large Business; and\n(h) Capability statement that addresses the organization s qualifications and ability to perform as a contractor for the work described below.\nThis Sources Sought is for Dwight D. Eisenhower VA Medical Center, Leavenworth, Kansas who have a requirement for Automatic Transfer Switch (ATS) Inspection, Preventive Maintenance, Repair Services, and Isolation Power Panel Inspection.\nThe NAICS Code is 238210 with a Small Business size standard of $19 million. SDVOSB/VOSB vendors must be registered in the SBA VetCert database.\nOfferors capable of providing this service shall notify the Contract Specialist no later than (NLT) August 11, 2026, 1:00 pm CST via email at maria.owen2@va.gov\nAll information is to be submitted via email to: maria.owen2@va.gov. Phone calls will not be accepted.\n\nPerformance Work Statement\nAutomatic Transfer Switch (ATS) Inspection, Preventive Maintenance, Repair Services, and Isolation Power Panel Inspection\n1. Scope\nThe Department of Veterans Affairs requires a qualified contractor to provide all labor, materials, equipment, tools, supervision, transportation, and technical expertise necessary to perform inspections, testing, preventive maintenance, repairs, and emergency response services for Automatic Transfer Switches (ATS) and Isolation Electrical Power Panels throughout the Dwight D. Eisenhower VA Medical Center, 4101 S 4th Street, Leavenworth, KS 66048. All work shall ensure safe, reliable, and code compliant operation of all systems.\n\n2. Period of Performance\nOctober 1, 2026 September 30, 2031\n3. Performance Objectives\nThe contractor shall deliver the following outcomes:\n3.1 ATS Systems\nEnsure all ATS units operate safely, reliably, and in accordance with NFPA standards and manufacturer specifications.\nMaintain full functionality of transfer and retransfer operations, voltage sensing, phase rotation, time delay functions, and ATS battery systems.\n3.2 Isolation Power Panels\nEnsure proper operation of Line Isolation Monitors (LIMs) and electrical isolation systems per NFPA 99.\nMaintain accurate, clearly labeled circuits consistent with facility electrical drawings.\n3.3 Emergency Repairs\nRestore system functionality rapidly for critical outages with minimal disruption to clinical operations.\n3.4 Compliance & Safety\nEnsure all work complies with NFPA 70, NFPA 70B, NFPA 99, OSHA, VA standards, and manufacturer guidelines.\n4. Performance Requirements\n4.1 ATS Inspection and Maintenance Tasks\nThe contractor shall perform and document the following measurable tasks:\nVisual inspection with photographic evidence.\nCleaning of enclosures using manufacturer approved methods.\nInfrared thermal scanning with image attachments.\nMeasurement and recording of temperature and torque values using calibrated instruments.\nOperational testing, documenting pass/fail for:\ntransfer\nretransfer\nvoltage sensing\ntime delay functions\nphase rotation\nATS battery testing where applicable (voltage, load test, specific gravity).\nLubrication of components using manufacturer specified lubricants.\nCoordinated generator functional testing, including recorded transfer and retransfer times.\n4.2 Isolation Panel Inspection and Testing Requirements\nThe contractor shall:\nProvide photographic documentation of panel inspections.\nTest LIMs, verify alarm set points, simulate faults, and document response times.\nPerform NFPA 99 compliant ground fault testing.\nMeasure voltage, current, and insulation resistance values.\nVerify labeling accuracy against electrical drawings.\nClean interiors with nonconductive tools and record methods.\nVerify torque values using calibrated instruments.\n5. Performance Standards\n\n6. Performance Monitoring (Government Surveillance)\nThe COR will evaluate contractor performance using the following methods:\nInspection of reports (routine & emergency) for accuracy and completeness.\nRandom onsite inspections of ATS and isolation panel systems.\nVerification of corrective action timelines.\nReview of emergency response logs.\n7. Deliverables\n7.1 Routine Service Reports Due within 48 hours\nReports shall include:\ndate/time of service\npersonnel names\nequipment inspected\nall measured values\nphotos and thermal images\npass/fail results\ndeficiencies and recommended corrective actions\nreferences to NFPA/manufacturer standards\n7.2 Emergency Repair Reports Due within 24 hours\nInclude issue description, corrective actions, parts replaced, test results, and verification of restored operation.\n7.3 Annual Executive Summary Due within 30 days\nProvide an overview of:\nsystem condition\nrecurring deficiencies\nreliability trends\nrecommended upgrades or corrective projects\n8. Contractor Qualifications\nContractor personnel shall:\nMaintain valid Kansas electrical licensing.\nHave documented experience with ATS and healthcare isolation power systems.\nComplete annual VA privacy, security, and safety training.\nPass VA background checks (VAAR 852.237 70).\nUse calibrated testing instruments.\nWear VA issued identification badges.\n9. Security & Safety Requirements\nContractor shall comply with:\nVA safety regulations\nOSHA regulations\nNFPA standards\nVA infection control procedures\n10. Non Conforming Performance\nFailure to perform may result in:\nNotice of Concern\nCorrective Action Request\nCure Notice in accordance with FAR 49.607\n\n11. List of Equipment\n\nAutomatic Transfer Switch List\nType\nCAT #\nSER #\nCUST DESIG\nASCO\nH07ATBB31200N5XM\n1329719-WE\nATS-4 122 Generator Shelter\nASCO\nJ07ATS30600C5XC\n2688889-001RE\nElevator ATS 88/89 SW GEAR\nZENITH\nZTS2L15FC-7\n1402776-1\nATS-4-EHC1A 91 North\nASCO\nJ07ATBB30400N5XC\n2564471-001WE\nATS-B91 01 91 North\nZENITH\nZTS000B00060E\n151048000-10-1\nATS-5-EHM1A 91 North\nZENITH\nZTS2L15FC-7\n1402776-2\nATS-3-GE-X-RAY 91 North\nZENITH\nZTS2L15EC-7\n1402847-2\nATS-1-EC1A 91 North\nZENITH\nZTS2L15EC-7\n1402847-1\nATS-2-EC21 91 North\nCUMMINS\nBTPCB-1500816\nB15M800254\nLift Station ATS Cemetery\nASCO\nG7AUBB31600C5XM\n1457708 WE\nATS 3 122 Platform\nASCO\nJ07ATBB30150C5XC\n1329727 WE\nATS-2 122 Sub-basement\nASCO\nJ07ATBB30600C5XC\n1329726 WE\nATS-1 122 Sub-basement\nASCO\nH07ATBB31200C5XC\n581676 WE\nBLD89_ATS-1 88/89\nZENITH\nZBTS00B10260F\n150163519-10-1\nChiller ATS-1 Bldg 161\nCUMMINS\nBTPCC-A073V586\nE23M241483\nPOWER HOUSE ATS\nASCO\nG07ATBB31600C5XC\n2731373-001WE\nBLD89 ATS-2 88/89\nASCO\nE0094003100095XC\n2443570-001WE\nDOM BLD 160\nASCO\nH07ATBA30800C5XC\n581679-FP\n91 ATS 1 91 South\n\nIsolation Panel Equipment\nItem #\nManufacturer\nPanel Type\nSerial Model\n1\nSquare D\nISO\n220525257\n2\nSquare D\nISO\n2201511637\n3\nSquare D\nISO\n2201524814\n4\nSquare D\nISO","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25526Q0584","place_of_performance":{"zip":"66048","city":{"name":"Leavenworth"},"state":{"name":"KS"},"street":"Dwight D. Eisenhower VA Medical Center 4101 S. 4th St."},"product_service_code":"J059"},{"award":{"awardee":{}},"dates":{"posted":"2026-08-04","posted_at":"2026-08-04T20:28:05.951Z","created_at":"2026-08-04T20:28:03.703Z","modified_at":"2026-09-10T05:07:48.881Z","response_deadline":{"raw":"2026-08-11T13:00:00-05:00","utc":"2026-08-11T18:00:00Z","date":"2026-08-11","time":"13:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/27cde944097c4b5fbfbe38873994e3a7/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","agency":{"office":{"code":"36C255","name":"255-NETWORK CONTRACT OFFICE 15 (36C255)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"66048","city":"LEAVENWORTH","state":"KS","country":"USA"},"organization_id":"100186523","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-09-10","archive_type":"auto_custom"},"history":[{"index":3,"title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-04T20:28:05.951Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"27cde944097c4b5fbfbe38873994e3a7","solicitation_number":"36C25526Q0584"}],"contacts":[{"name":"Maria Riza R. Owen","role":"primary","email":"maria.owen2@va.gov","phone":"913-946-1965","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"27cde944097c4b5fbfbe38873994e3a7","lineage_id":"27cde944097c4b5fbfbe38873994e3a7","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-26T03:06:16.571873857Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"08c0017f0c46822383fb1286b7cc0209d38e9ed26fc14adb71daf2b610497c6b","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-26T03:06:16.571873857Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"Sources Sought Notice:\nThis is not a request for formal proposals or quotes, it does not obligate the Government to award a contract. Requests for a solicitation will not receive a response. Responses to this Sources Sought must be in writing. \nThe purpose of this Sources Sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potentially qualified businesses interested in and capable of providing the required services.  \nDocumentation of technical expertise must be presented in sufficient detail for the government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. \nResponses to this notice shall include the following: \n(a) company name \n(b) address \n(c) point of contact \n(d) phone and email\n(e) UEI number \n(f) Cage Code \n(g) Type of small business, e.g., Services Disabled Veteran Owned Small Business, Veteran-Owned Small Business, 8(a), HUBZone, Women Owned Small Business, Small Disadvantaged Business, Small Business, or Large Business; and \n(h) Capability statement that addresses the organization s qualifications and ability to perform as a contractor for the work described below.\nThis Sources Sought is for Dwight D. Eisenhower VA Medical Center, Leavenworth, Kansas who have a requirement for Automatic Transfer Switch (ATS) Inspection, Preventive Maintenance, Repair Services, and Isolation Power Panel Inspection.\nThe NAICS Code is 238210 with a Small Business size standard of $19 million. SDVOSB/VOSB vendors must be registered in the SBA VetCert database. \nOfferors capable of providing this service shall notify the Contract Specialist no later than (NLT) August 11, 2026, 1:00 pm CST via email at maria.owen2@va.gov\nAll information is to be submitted via email to: maria.owen2@va.gov. Phone calls will not be accepted.\n\n\nPerformance Work Statement \nAutomatic Transfer Switch (ATS) Inspection, Preventive Maintenance, Repair Services, and Isolation Power Panel Inspection\n1. Scope \nThe Department of Veterans Affairs requires a qualified contractor to provide all labor, materials, equipment, tools, supervision, transportation, and technical expertise necessary to perform inspections, testing, preventive maintenance, repairs, and emergency response services for Automatic Transfer Switches (ATS) and Isolation Electrical Power Panels throughout the Dwight D. Eisenhower VA Medical Center, 4101 S 4th Street, Leavenworth, KS 66048. All work shall ensure safe, reliable, and code compliant operation of all systems. \n\n2. Period of Performance\nOctober 1, 2026   September 30, 2031\n3. Performance Objectives\nThe contractor shall deliver the following outcomes:\n     3.1 ATS Systems\nEnsure all ATS units operate safely, reliably, and in accordance with NFPA standards and manufacturer specifications.\nMaintain full functionality of transfer and retransfer operations, voltage sensing, phase rotation, time delay functions, and ATS battery systems.\n      3.2 Isolation Power Panels\nEnsure proper operation of Line Isolation Monitors (LIMs) and electrical isolation systems per NFPA 99.\nMaintain accurate, clearly labeled circuits consistent with facility electrical drawings.\n     3.3 Emergency Repairs\nRestore system functionality rapidly for critical outages with minimal disruption to clinical operations.\n      3.4 Compliance & Safety\nEnsure all work complies with NFPA 70, NFPA 70B, NFPA 99, OSHA, VA standards, and manufacturer guidelines.\n4. Performance Requirements\n      4.1 ATS Inspection and Maintenance Tasks\nThe contractor shall perform and document the following measurable tasks:\nVisual inspection with photographic evidence.\nCleaning of enclosures using manufacturer approved methods.\nInfrared thermal scanning with image attachments.\nMeasurement and recording of temperature and torque values using calibrated instruments.\nOperational testing, documenting pass/fail for: \ntransfer\nretransfer\nvoltage sensing\ntime delay functions\nphase rotation\nATS battery testing where applicable (voltage, load test, specific gravity).\nLubrication of components using manufacturer specified lubricants.\nCoordinated generator functional testing, including recorded transfer and retransfer times.\n4.2 Isolation Panel Inspection and Testing Requirements\nThe contractor shall:\nProvide photographic documentation of panel inspections.\nTest LIMs, verify alarm set points, simulate faults, and document response times.\nPerform NFPA 99 compliant ground fault testing.\nMeasure voltage, current, and insulation resistance values.\nVerify labeling accuracy against electrical drawings.\nClean interiors with nonconductive tools and record methods.\nVerify torque values using calibrated instruments.\n5. Performance Standards\n\n6. Performance Monitoring (Government Surveillance)\nThe COR will evaluate contractor performance using the following methods:\nInspection of reports (routine & emergency) for accuracy and completeness.\nRandom onsite inspections of ATS and isolation panel systems.\nVerification of corrective action timelines.\nReview of emergency response logs.\n7. Deliverables\n      7.1 Routine Service Reports   Due within 48 hours\nReports shall include:\ndate/time of service\npersonnel names\nequipment inspected\nall measured values\nphotos and thermal images\npass/fail results\ndeficiencies and recommended corrective actions\nreferences to NFPA/manufacturer standards\n7.2 Emergency Repair Reports   Due within 24 hours\nInclude issue description, corrective actions, parts replaced, test results, and verification of restored operation.\n7.3 Annual Executive Summary   Due within 30 days\nProvide an overview of:\nsystem condition\nrecurring deficiencies\nreliability trends\nrecommended upgrades or corrective projects\n8. Contractor Qualifications\nContractor personnel shall:\nMaintain valid Kansas electrical licensing.\nHave documented experience with ATS and healthcare isolation power systems.\nComplete annual VA privacy, security, and safety training.\nPass VA background checks (VAAR 852.237 70).\nUse calibrated testing instruments.\nWear VA issued identification badges.\n9. Security & Safety Requirements\nContractor shall comply with:\nVA safety regulations\nOSHA regulations\nNFPA standards\nVA infection control procedures\n10. Non Conforming Performance\nFailure to perform may result in:\nNotice of Concern\nCorrective Action Request\nCure Notice in accordance with FAR 49.607\n\n11. List of Equipment\n\nAutomatic Transfer Switch List\nType\nCAT #\nSER #\nCUST DESIG\nASCO\nH07ATBB31200N5XM\n1329719-WE\nATS-4 122 Generator Shelter\nASCO\nJ07ATS30600C5XC\n2688889-001RE\nElevator ATS 88/89 SW GEAR\nZENITH\nZTS2L15FC-7\n1402776-1\nATS-4-EHC1A 91 North\nASCO\nJ07ATBB30400N5XC\n2564471-001WE\nATS-B91 01 91 North\nZENITH\nZTS000B00060E\n151048000-10-1\nATS-5-EHM1A 91 North\nZENITH\nZTS2L15FC-7\n1402776-2\nATS-3-GE-X-RAY 91 North\nZENITH\nZTS2L15EC-7\n1402847-2\nATS-1-EC1A 91 North\nZENITH\nZTS2L15EC-7\n1402847-1\nATS-2-EC21 91 North\nCUMMINS\nBTPCB-1500816\nB15M800254\nLift Station ATS Cemetery\nASCO\nG7AUBB31600C5XM\n1457708 WE\nATS 3 122 Platform\nASCO\nJ07ATBB30150C5XC\n1329727 WE\nATS-2 122 Sub-basement\nASCO\nJ07ATBB30600C5XC\n1329726 WE\nATS-1 122 Sub-basement\nASCO\nH07ATBB31200C5XC\n581676 WE\nBLD89_ATS-1 88/89\nZENITH\nZBTS00B10260F\n150163519-10-1\nChiller ATS-1 Bldg 161\nCUMMINS\nBTPCC-A073V586\nE23M241483\nPOWER HOUSE ATS\nASCO\nG07ATBB31600C5XC\n2731373-001WE\nBLD89 ATS-2 88/89\nASCO\nE0094003100095XC\n2443570-001WE\nDOM BLD 160\nASCO\nH07ATBA30800C5XC\n581679-FP\n91 ATS 1 91 South\n\n\n\n\n\n\n\nIsolation Panel Equipment\nItem #\nManufacturer\nPanel Type\nSerial Model\n1\nSquare D\nISO\n220525257\n2\nSquare D\nISO\n2201511637\n3\nSquare D\nISO\n2201524814\n4\nSquare D\nISO","text":"Sources Sought Notice:\nThis is not a request for formal proposals or quotes, it does not obligate the Government to award a contract. Requests for a solicitation will not receive a response. Responses to this Sources Sought must be in writing.\nThe purpose of this Sources Sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potentially qualified businesses interested in and capable of providing the required services.\nDocumentation of technical expertise must be presented in sufficient detail for the government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition.\nResponses to this notice shall include the following:\n(a) company name\n(b) address\n(c) point of contact\n(d) phone and email\n(e) UEI number\n(f) Cage Code\n(g) Type of small business, e.g., Services Disabled Veteran Owned Small Business, Veteran-Owned Small Business, 8(a), HUBZone, Women Owned Small Business, Small Disadvantaged Business, Small Business, or Large Business; and\n(h) Capability statement that addresses the organization s qualifications and ability to perform as a contractor for the work described below.\nThis Sources Sought is for Dwight D. Eisenhower VA Medical Center, Leavenworth, Kansas who have a requirement for Automatic Transfer Switch (ATS) Inspection, Preventive Maintenance, Repair Services, and Isolation Power Panel Inspection.\nThe NAICS Code is 238210 with a Small Business size standard of $19 million. SDVOSB/VOSB vendors must be registered in the SBA VetCert database.\nOfferors capable of providing this service shall notify the Contract Specialist no later than (NLT) August 11, 2026, 1:00 pm CST via email at maria.owen2@va.gov\nAll information is to be submitted via email to: maria.owen2@va.gov. Phone calls will not be accepted.\n\nPerformance Work Statement\nAutomatic Transfer Switch (ATS) Inspection, Preventive Maintenance, Repair Services, and Isolation Power Panel Inspection\n1. Scope\nThe Department of Veterans Affairs requires a qualified contractor to provide all labor, materials, equipment, tools, supervision, transportation, and technical expertise necessary to perform inspections, testing, preventive maintenance, repairs, and emergency response services for Automatic Transfer Switches (ATS) and Isolation Electrical Power Panels throughout the Dwight D. Eisenhower VA Medical Center, 4101 S 4th Street, Leavenworth, KS 66048. All work shall ensure safe, reliable, and code compliant operation of all systems.\n\n2. Period of Performance\nOctober 1, 2026 September 30, 2031\n3. Performance Objectives\nThe contractor shall deliver the following outcomes:\n3.1 ATS Systems\nEnsure all ATS units operate safely, reliably, and in accordance with NFPA standards and manufacturer specifications.\nMaintain full functionality of transfer and retransfer operations, voltage sensing, phase rotation, time delay functions, and ATS battery systems.\n3.2 Isolation Power Panels\nEnsure proper operation of Line Isolation Monitors (LIMs) and electrical isolation systems per NFPA 99.\nMaintain accurate, clearly labeled circuits consistent with facility electrical drawings.\n3.3 Emergency Repairs\nRestore system functionality rapidly for critical outages with minimal disruption to clinical operations.\n3.4 Compliance & Safety\nEnsure all work complies with NFPA 70, NFPA 70B, NFPA 99, OSHA, VA standards, and manufacturer guidelines.\n4. Performance Requirements\n4.1 ATS Inspection and Maintenance Tasks\nThe contractor shall perform and document the following measurable tasks:\nVisual inspection with photographic evidence.\nCleaning of enclosures using manufacturer approved methods.\nInfrared thermal scanning with image attachments.\nMeasurement and recording of temperature and torque values using calibrated instruments.\nOperational testing, documenting pass/fail for:\ntransfer\nretransfer\nvoltage sensing\ntime delay functions\nphase rotation\nATS battery testing where applicable (voltage, load test, specific gravity).\nLubrication of components using manufacturer specified lubricants.\nCoordinated generator functional testing, including recorded transfer and retransfer times.\n4.2 Isolation Panel Inspection and Testing Requirements\nThe contractor shall:\nProvide photographic documentation of panel inspections.\nTest LIMs, verify alarm set points, simulate faults, and document response times.\nPerform NFPA 99 compliant ground fault testing.\nMeasure voltage, current, and insulation resistance values.\nVerify labeling accuracy against electrical drawings.\nClean interiors with nonconductive tools and record methods.\nVerify torque values using calibrated instruments.\n5. Performance Standards\n\n6. Performance Monitoring (Government Surveillance)\nThe COR will evaluate contractor performance using the following methods:\nInspection of reports (routine & emergency) for accuracy and completeness.\nRandom onsite inspections of ATS and isolation panel systems.\nVerification of corrective action timelines.\nReview of emergency response logs.\n7. Deliverables\n7.1 Routine Service Reports Due within 48 hours\nReports shall include:\ndate/time of service\npersonnel names\nequipment inspected\nall measured values\nphotos and thermal images\npass/fail results\ndeficiencies and recommended corrective actions\nreferences to NFPA/manufacturer standards\n7.2 Emergency Repair Reports Due within 24 hours\nInclude issue description, corrective actions, parts replaced, test results, and verification of restored operation.\n7.3 Annual Executive Summary Due within 30 days\nProvide an overview of:\nsystem condition\nrecurring deficiencies\nreliability trends\nrecommended upgrades or corrective projects\n8. Contractor Qualifications\nContractor personnel shall:\nMaintain valid Kansas electrical licensing.\nHave documented experience with ATS and healthcare isolation power systems.\nComplete annual VA privacy, security, and safety training.\nPass VA background checks (VAAR 852.237 70).\nUse calibrated testing instruments.\nWear VA issued identification badges.\n9. Security & Safety Requirements\nContractor shall comply with:\nVA safety regulations\nOSHA regulations\nNFPA standards\nVA infection control procedures\n10. Non Conforming Performance\nFailure to perform may result in:\nNotice of Concern\nCorrective Action Request\nCure Notice in accordance with FAR 49.607\n\n11. List of Equipment\n\nAutomatic Transfer Switch List\nType\nCAT #\nSER #\nCUST DESIG\nASCO\nH07ATBB31200N5XM\n1329719-WE\nATS-4 122 Generator Shelter\nASCO\nJ07ATS30600C5XC\n2688889-001RE\nElevator ATS 88/89 SW GEAR\nZENITH\nZTS2L15FC-7\n1402776-1\nATS-4-EHC1A 91 North\nASCO\nJ07ATBB30400N5XC\n2564471-001WE\nATS-B91 01 91 North\nZENITH\nZTS000B00060E\n151048000-10-1\nATS-5-EHM1A 91 North\nZENITH\nZTS2L15FC-7\n1402776-2\nATS-3-GE-X-RAY 91 North\nZENITH\nZTS2L15EC-7\n1402847-2\nATS-1-EC1A 91 North\nZENITH\nZTS2L15EC-7\n1402847-1\nATS-2-EC21 91 North\nCUMMINS\nBTPCB-1500816\nB15M800254\nLift Station ATS Cemetery\nASCO\nG7AUBB31600C5XM\n1457708 WE\nATS 3 122 Platform\nASCO\nJ07ATBB30150C5XC\n1329727 WE\nATS-2 122 Sub-basement\nASCO\nJ07ATBB30600C5XC\n1329726 WE\nATS-1 122 Sub-basement\nASCO\nH07ATBB31200C5XC\n581676 WE\nBLD89_ATS-1 88/89\nZENITH\nZBTS00B10260F\n150163519-10-1\nChiller ATS-1 Bldg 161\nCUMMINS\nBTPCC-A073V586\nE23M241483\nPOWER HOUSE ATS\nASCO\nG07ATBB31600C5XC\n2731373-001WE\nBLD89 ATS-2 88/89\nASCO\nE0094003100095XC\n2443570-001WE\nDOM BLD 160\nASCO\nH07ATBA30800C5XC\n581679-FP\n91 ATS 1 91 South\n\nIsolation Panel Equipment\nItem #\nManufacturer\nPanel Type\nSerial Model\n1\nSquare D\nISO\n220525257\n2\nSquare D\nISO\n2201511637\n3\nSquare D\nISO\n2201524814\n4\nSquare D\nISO","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25526Q0584","place_of_performance":{"zip":"66048","city":{"name":"Leavenworth"},"state":{"name":"KS"},"street":"Dwight D. Eisenhower VA Medical Center 4101 S. 4th St."},"product_service_code":"J059"},{"dates":{"posted":"2026-09-01","posted_at":"2026-09-01T21:11:23.497Z","created_at":"2026-09-01T21:11:21.246Z","modified_at":"2026-09-10T14:15:06.183Z","response_deadline":{"raw":"2026-10-02T13:00:00-05:00","utc":"2026-10-02T18:00:00Z","date":"2026-10-02","time":"13:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/282a5419770a4285855fe228228701d5/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","agency":{"office":{"code":"36C255","name":"255-NETWORK CONTRACT OFFICE 15 (36C255)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"66048","city":"LEAVENWORTH","state":"KS","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":false,"publication":"published","archive_date":"2026-11-01","archive_type":"auto_custom"},"history":[{"index":5,"title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-10T14:15:06.183Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"7fb152917d8942399878b2b101f646d1","solicitation_number":"36C25526Q0584_0001","parent_opportunity_id":"282a5419770a4285855fe228228701d5","related_opportunity_id":"0998fb8dabb446df9b5f2d2d828955fc"},{"index":4,"title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-04T20:28:07.323Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"0998fb8dabb446df9b5f2d2d828955fc","solicitation_number":"36C25526Q0584"},{"index":2,"title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-01T21:11:23.497Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"282a5419770a4285855fe228228701d5","solicitation_number":"36C25526Q0584","related_opportunity_id":"0998fb8dabb446df9b5f2d2d828955fc"}],"contacts":[{"name":"Maria Riza R. Owen","role":"primary","email":"maria.owen2@va.gov","phone":"913-946-1122","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"282a5419770a4285855fe228228701d5","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"282a5419770a4285855fe228228701d5","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-17T02:15:59.302062019Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"9ad19a7f9420926246b2a3b64ab4015bd5700af6966883e7092f4dfd4a172844","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-09-15T22:52:52.472456Z"},"description":{"html":"Combined Synopsis/Solicitation Notice\n\nDESCRIPTION\nThis is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes the only solicitation. Offers are being requested and a separate written solicitation will not be issued.\nSolicitation number 36C25526Q0584 is issued as a request for quotation (RFQ), for Automatic Transfer Switch (ATS) Preventive Maintenance and Repair Services, and Isolation Power Panel Inspection\nThis acquisition is set-aside for small business concerns. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov","text":"Combined Synopsis/Solicitation Notice\n\nDESCRIPTION\nThis is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes the only solicitation. Offers are being requested and a separate written solicitation will not be issued.\nSolicitation number 36C25526Q0584 is issued as a request for quotation (RFQ), for Automatic Transfer Switch (ATS) Preventive Maintenance and Repair Services, and Isolation Power Panel Inspection\nThis acquisition is set-aside for small business concerns. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C25526Q0584","place_of_performance":{"zip":"66048","city":{"name":"Leavenworth"},"street":"Dwight D. Eisenhower VA Medical Center 4101 S. 4th St."},"product_service_code":"J059"},{"dates":{"posted":"2026-09-01","posted_at":"2026-09-01T21:11:23.429Z","created_at":"2026-09-01T21:11:21.189Z","modified_at":"2026-09-01T21:11:23.429Z","response_deadline":{"raw":"2026-10-02T13:00:00-05:00","utc":"2026-10-02T18:00:00Z","date":"2026-10-02","time":"13:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/2ef7bf2cd79d471aaab4cca71038c75b/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","agency":{"office":{"code":"36C255","name":"255-NETWORK CONTRACT OFFICE 15 (36C255)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"66048","city":"LEAVENWORTH","state":"KS","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"publication":"published","archive_date":"2026-11-01","archive_type":"auto_custom"},"history":[{"index":4,"title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-04T20:28:07.323Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"0998fb8dabb446df9b5f2d2d828955fc","solicitation_number":"36C25526Q0584"},{"index":2,"title":"J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC |","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-01T21:11:23.429Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"2ef7bf2cd79d471aaab4cca71038c75b","solicitation_number":"36C25526Q0584","related_opportunity_id":"0998fb8dabb446df9b5f2d2d828955fc"}],"contacts":[{"name":"Maria Riza R. Owen","role":"primary","email":"maria.owen2@va.gov","phone":"913-946-1122","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"2ef7bf2cd79d471aaab4cca71038c75b","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"2ef7bf2cd79d471aaab4cca71038c75b","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-17T02:17:35.806539766Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"7294cfb0ad67caf4ef51f9307d4331705c1ec7667b9771935afd15dbc59b9396","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-09-15T22:52:52.472456Z"},"description":{"html":"Combined Synopsis/Solicitation Notice\n\nDESCRIPTION\nThis is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes the only solicitation. Offers are being requested and a separate written solicitation will not be issued.\nSolicitation number 36C25526Q0584 is issued as a request for quotation (RFQ), for Automatic Transfer Switch (ATS) Preventive Maintenance and Repair Services, and Isolation Power Panel Inspection\nThis acquisition is set-aside for small business concerns. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov","text":"Combined Synopsis/Solicitation Notice\n\nDESCRIPTION\nThis is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes the only solicitation. Offers are being requested and a separate written solicitation will not be issued.\nSolicitation number 36C25526Q0584 is issued as a request for quotation (RFQ), for Automatic Transfer Switch (ATS) Preventive Maintenance and Repair Services, and Isolation Power Panel Inspection\nThis acquisition is set-aside for small business concerns. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C25526Q0584","place_of_performance":{"zip":"66048","city":{"name":"Leavenworth"},"street":"Dwight D. Eisenhower VA Medical Center 4101 S. 4th St."},"product_service_code":"J059"}],"due_at":"2026-10-02T18:00:00Z","due_date":"2026-10-02","closes_at":"2026-10-02T18:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","state":"KS","county":"20103","county_name":"Leavenworth County","city":"2039000","city_name":"Leavenworth","country":null,"state_source":null,"state_evidence":null,"site_key":"leavenworth-va-medical-center-ks","winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-02T00:27:51.121586Z","principal_notice_id":"2ef7bf2cd79d471aaab4cca71038c75b","description":{"text":"Combined Synopsis/Solicitation Notice\n\nDESCRIPTION\nThis is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes the only solicitation. Offers are being requested and a separate written solicitation will not be issued.\nSolicitation number 36C25526Q0584 is issued as a request for quotation (RFQ), for Automatic Transfer Switch (ATS) Preventive Maintenance and Repair Services, and Isolation Power Panel Inspection\nThis acquisition is set-aside for small business concerns. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov","html":"Combined Synopsis/Solicitation Notice\n\nDESCRIPTION\nThis is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes the only solicitation. Offers are being requested and a separate written solicitation will not be issued.\nSolicitation number 36C25526Q0584 is issued as a request for quotation (RFQ), for Automatic Transfer Switch (ATS) Preventive Maintenance and Repair Services, and Isolation Power Panel Inspection\nThis acquisition is set-aside for small business concerns. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov","origin":"detail"},"contacts":[{"name":"Maria Riza R. Owen","role":"primary","email":"maria.owen2@va.gov","phone":"913-946-1122","title":"Contract Specialist"}],"place_of_performance":{"zip":"66048","city":{"name":"Leavenworth"},"street":"Dwight D. Eisenhower VA Medical Center 4101 S. 4th St."},"office_address":{"zip":"66048","city":"LEAVENWORTH","state":"KS","country":"USA"},"naics_codes":["238210"],"award":null,"attachments":[{"resource_id":"6a255cc86b8242c5b91d3e0535cda130","name":"36C25526Q0584.docx","kind":"file","mime_type":".docx","size_bytes":29451,"posted_at":"2026-08-04T20:28:05.951Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/6a255cc86b8242c5b91d3e0535cda130/download","mirrored":false},{"resource_id":"786787abdf2a49b6aa45ab205c93fbda","name":"36C25526Q0584.docx","kind":"file","mime_type":".docx","size_bytes":29451,"posted_at":"2026-08-04T20:28:07.323Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/786787abdf2a49b6aa45ab205c93fbda/download","mirrored":false},{"resource_id":"325857bf7e2c4400b114675d57a42fd1","name":"36C25526Q0584_1.docx","kind":"file","mime_type":".docx","size_bytes":118352,"posted_at":"2026-09-01T21:11:23.429Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/325857bf7e2c4400b114675d57a42fd1/download","mirrored":false},{"resource_id":"bf590cb14f924117abcbc5a4712b487e","name":"36C25526Q0584_1.docx","kind":"file","mime_type":".docx","size_bytes":118352,"posted_at":"2026-09-01T21:11:23.497Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/bf590cb14f924117abcbc5a4712b487e/download","mirrored":false}],"awards":[],"related":[{"key":"36C25527R0016","latest_notice_id":"a7eee67b427c47158525b1a79fc8ecd2","title":"Z2DA--657-24-102JC - Prepare Site for New PET/CT, Room A011D (MD) FY27 NRM VISN Base, CON (VA-27-00017492) 657-27-1-8434-0001","solicitation_number":"36C25527R0016","notice_type":"p","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"236220","psc":"Z2DA","set_aside":"SDVOSBC","state":"MO","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"WORK: THE GENERAL DESCRIPTION: VA SAINT LOUIS HEALTH CARE SYSTEM","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C25526Q0617","latest_notice_id":"3506983a2af048deaf442eae0f8b8a04","title":"H112--Annual/Sem-i annual fire smoke inspections and auto door services l EKH","solicitation_number":"36C25526Q0617","notice_type":"o","first_type":"r","first_posted":"2026-08-19","last_posted":"2026-11-18","notices":11,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"541350","psc":"H112","set_aside":"SBA","state":"KS","county":"20103","county_name":"Leavenworth County","city":"2039000","city_name":"Leavenworth","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C25527Q0057","latest_notice_id":"fbd76a4c366d45e896674756383b4fb2","title":"C222--589-27-108, Correct Electrical Deficiencies in Building 26 KCVA (ME) FY27 NRM VISN Base - AE (VA-27-00021035)","solicitation_number":"36C25527Q0057","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":2,"due_at":"2026-12-01T20:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"541330","psc":"C222","set_aside":"EDWOSB","state":"MO","county":"29095","county_name":"Jackson County","city":"2938000","city_name":"Kansas City","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T09:15:14.204648Z"},{"key":"36C25527Q00571","latest_notice_id":"53c5d2376d9e4fb79d39a712a62deb10","title":"C222--589-27-108, Correct Electrical Deficiencies in Building 26 KCVA (ME) FY27 NRM VISN Base - AE (VA-27-00021035)","solicitation_number":"36C25527Q0057_1","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-12-01T20:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"541330","psc":"C222","set_aside":"SDVOSBC","state":"MO","county":"29095","county_name":"Jackson County","city":"2938000","city_name":"Kansas City","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C25527Q0053","latest_notice_id":"f87b14f3ce2643d69bdc633c0b05a712","title":"J065--Imaging Service & Maintenance EHCC & MTV","solicitation_number":"36C25527Q0053","notice_type":"o","first_type":"p","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":2,"due_at":"2026-12-02T14:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"811210","psc":"J065","set_aside":null,"state":"IN","county":"18163","county_name":"Vanderburgh County","city":"1822000","city_name":"Evansville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open":[{"key":"36C25527Q0045","latest_notice_id":"1df32ea015504033a409cf09ac4a4d7e","title":"Automatic Transfer Switch (ATS) Preventive Maintenance and Repair Services, and Isolation Power Panel Inspection","solicitation_number":"36C25527Q0045","notice_type":"o","first_type":"o","first_posted":"2026-11-02","last_posted":"2026-11-23","notices":2,"due_at":"2026-12-04T19:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"238210","psc":"J059","set_aside":null,"state":"KS","county":"20103","county_name":"Leavenworth County","city":"2039000","city_name":"Leavenworth","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C25027Q0014","latest_notice_id":"b13cc87179e947e7b42da2de44a6bde1","title":"J061--541 Electrical Power Distribution Equipment Testing, Inspection, and Maintenance - VAMC Cleveland","solicitation_number":"36C25027Q0014","notice_type":"k","first_type":"k","first_posted":"2026-10-09","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"238210","psc":"J061","set_aside":"SBA","state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"127EAW27Q0002","latest_notice_id":"59c24c6aad3541448f35b465324ba88b","title":"Forest Service - Solar Batteries Frenchman Work Center","solicitation_number":"127EAW27Q0002","notice_type":"k","first_type":"k","first_posted":"2026-11-05","last_posted":"2026-11-17","notices":3,"due_at":"2026-11-28T00:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-28T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12C2","sub_name":"FOREST SERVICE","office_key":"o-127EAW","office_name":"USDA-FS, CSA SOUTHWEST 6","naics":"238210","psc":"N061","set_aside":"SBA","state":"CA","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"}],"similar_open_total":40,"indexable":false}