{"canonical":"https://sealedbidder.com/opportunities/36c25526q0562","key":"36C25526Q0562","url":"https://sealedbidder.com/opportunities/36c25526q0562","title":"C-ARM TABLE","solicitation_number":"36C25526Q0562","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-08-10T16:00:00Z","first_posted":"2026-08-03","last_posted":"2026-08-03","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"339113","psc":"6515","set_aside":null,"place_state":"KS","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"20103","place_county_name":"Leavenworth County","place_city":"2039000","place_city_name":"Leavenworth","winner":null,"award_amount":null,"publications":[{"notice_id":"dea1e42824b64837867f5014ccec132b","title":"C-ARM TABLE","solicitation_number":"36C25526Q0562","notice_type":"r","base_type":"r","posted":"2026-08-03","posted_at":"2026-08-03T20:10:49.882Z","due_at":"2026-08-10T16:00:00Z","due_date":"2026-08-10","cancelled":false,"archived":true,"archive_date":"2026-08-25","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/dea1e42824b64837867f5014ccec132b/view","enriched":true,"history":[{"index":3,"title":"C-ARM TABLE","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-03T20:10:49.882Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"dea1e42824b64837867f5014ccec132b","solicitation_number":"36C25526Q0562"}]}],"latest_notice_id":"dea1e42824b64837867f5014ccec132b","first_type":"r","notices":[{"dates":{"posted":"2026-08-03","posted_at":"2026-08-03T20:10:49.882Z","created_at":"2026-08-03T20:06:37.583Z","modified_at":"2026-08-25T05:06:54.835Z","response_deadline":{"raw":"2026-08-10T11:00:00-05:00","utc":"2026-08-10T16:00:00Z","date":"2026-08-10","time":"11:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/dea1e42824b64837867f5014ccec132b/view"},"naics":{"codes":["339113"],"primary":"339113"},"title":"C-ARM TABLE","agency":{"office":{"code":"36C255","name":"255-NETWORK CONTRACT OFFICE 15 (36C255)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"66048","city":"LEAVENWORTH","state":"KS","country":"USA"},"organization_id":"100186523","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-25","archive_type":"auto15"},"history":[{"index":3,"title":"C-ARM TABLE","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-03T20:10:49.882Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"dea1e42824b64837867f5014ccec132b","solicitation_number":"36C25526Q0562"}],"contacts":[{"name":"Jon Lutmer","role":"primary","email":"Jonathan.lutmer@va.gov","phone":"4104463862"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"dea1e42824b64837867f5014ccec132b","lineage_id":"dea1e42824b64837867f5014ccec132b","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-27T00:27:30.924848294Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"e023e13380c1efb5db954a24485d1245c08a58fdea09e8de522711cdefb436b9","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-27T00:27:30.924848294Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>Eastern Kansas<br />\nStatement of Work: 4 Motion C-Arm Imaging Table<br />\nThe purpose of this document is to provide a statement of work (SOW), for two 4 Motion C-Arm<br />\nImaging Tables, one for each VA Eastern Kansas campus to be utilized by surgical staff. The<br />\nImaging Tables have a large height range helping to create safe patient transfers while allowing<br />\ndoctors to stand comfortably. The large lifting column is very rigid, ensuring rock solid support<br />\nfor fast imaging and procedures.<br />\nThe station requires two FDA-listed, CE-marked, electrically motorized C-Arm imaging tables for<br />\npain management and surgical procedures. The tables must support safe patient transfers,<br />\nprecise imaging, and stable positioning for both fluoroscopy and ultrasound-guided<br />\ninterventions. The tables must be compatible with mobile C-Arm systems and support a wide<br />\nrange of patient sizes and procedural requirements.<br />\nA C-Arm is a mobile fluoroscopy imaging system shaped like the letter &ldquo;C,&rdquo; allowing real-time Xray<br />\nimaging during procedures. The C-Arm rotates around the patient to provide multiple views<br />\n(lateral, oblique, anteroposterior) without repositioning the patient. The CFPM400 table&rsquo;s<br />\nradiolucent design and metal-free imaging space ensure the C-Arm can capture clear images of<br />\nthe spine and target anatomy in any projection. The table&rsquo;s adjustable movements allow optimal<br />\npositioning for both the patient and the C-Arm, supporting safe and efficient image-guided<br />\ninterventions.<br />\nObjectives:<br />\n&bull; Improve patient comfort during imaging and procedures.<br />\n&bull; Enhance the stability, precision imaging and procedures.<br />\n&bull; Increase operational efficiency in the surgical departments.<br />\nRequirements (shall meet or exceed):<br />\nTechnical Specifications:<br />\n&bull; Integrated Headrest Top: 22&rdquo; (56cm) wide x 84&rdquo; (214cm) long<br />\n&bull; Rectangular Top: 24&rdquo; (61cm) wide x 80&rdquo; (203cm) long<br />\nSources Sought Notice<br />\nSources Sought Notice<br />\nPage 5 of 5<br />\n&bull; Imaging Space:<br />\n&bull; 56&rdquo; metal-free imaging space (no obstructions for C-Arm imaging)<br />\n&bull; Height Range:<br />\n&bull; Electric height adjustment from 26&rdquo; to 43&rdquo; (CFPM400)<br />\n&bull; Weight capacity: 500 lb (227kg)<br />\n&bull; Product weight: 475 lb (216kg)<br />\nMovements &amp; Controls:<br />\n Motion 1: Electric height adjustment (26&rdquo;&ndash;43&rdquo;)<br />\n Motion 2: Electric Trendelenburg tilt (+15&deg;/-11&deg;)<br />\n Motion 3: Electric longitudinal travel (10&rdquo;)<br />\n Motion 4: Electric lateral tilt (&plusmn;15&deg;)<br />\n All functions are controlled via a hand control (foot control optional).<br />\n Table includes 2&rdquo; radiolucent comfort foam pad, locking casters, patient restraint straps,<br />\nand crescent face rest pad (with integrated headrest).<br />\nRadiolucency:<br />\n Carbon fiber construction ensures full radiolucency for unobstructed imaging during<br />\nfluoroscopy.<br />\n The table and accessories are designed to minimize imaging artifacts and maximize<br />\nvisualization of cervical, thoracic, and lumbar regions.<br />\nSafety, Compliance, and Warranty<br />\n FDA listed, CE marked, cETLus listed, CB Certificate<br />\n Warranty: 4 years parts, 3 years labor<br />\n Safety features include locking casters and patient restraint straps<br />\nMade in USA Compliance<br />\n Vendors must provide written certification of country of origin and compliance with Buy<br />\nAmerican Act requirements</p>","text":"Eastern Kansas\n\nStatement of Work: 4 Motion C-Arm Imaging Table\n\nThe purpose of this document is to provide a statement of work (SOW), for two 4 Motion C-Arm\n\nImaging Tables, one for each VA Eastern Kansas campus to be utilized by surgical staff. The\n\nImaging Tables have a large height range helping to create safe patient transfers while allowing\n\ndoctors to stand comfortably. The large lifting column is very rigid, ensuring rock solid support\n\nfor fast imaging and procedures.\n\nThe station requires two FDA-listed, CE-marked, electrically motorized C-Arm imaging tables for\n\npain management and surgical procedures. The tables must support safe patient transfers,\n\nprecise imaging, and stable positioning for both fluoroscopy and ultrasound-guided\n\ninterventions. The tables must be compatible with mobile C-Arm systems and support a wide\n\nrange of patient sizes and procedural requirements.\n\nA C-Arm is a mobile fluoroscopy imaging system shaped like the letter “C,” allowing real-time Xray\n\nimaging during procedures. The C-Arm rotates around the patient to provide multiple views\n\n(lateral, oblique, anteroposterior) without repositioning the patient. The CFPM400 table’s\n\nradiolucent design and metal-free imaging space ensure the C-Arm can capture clear images of\n\nthe spine and target anatomy in any projection. The table’s adjustable movements allow optimal\n\npositioning for both the patient and the C-Arm, supporting safe and efficient image-guided\n\ninterventions.\n\nObjectives:\n\n• Improve patient comfort during imaging and procedures.\n\n• Enhance the stability, precision imaging and procedures.\n\n• Increase operational efficiency in the surgical departments.\n\nRequirements (shall meet or exceed):\n\nTechnical Specifications:\n\n• Integrated Headrest Top: 22” (56cm) wide x 84” (214cm) long\n\n• Rectangular Top: 24” (61cm) wide x 80” (203cm) long\n\nSources Sought Notice\n\nSources Sought Notice\n\nPage 5 of 5\n\n• Imaging Space:\n\n• 56” metal-free imaging space (no obstructions for C-Arm imaging)\n\n• Height Range:\n\n• Electric height adjustment from 26” to 43” (CFPM400)\n\n• Weight capacity: 500 lb (227kg)\n\n• Product weight: 475 lb (216kg)\n\nMovements & Controls:\n\n Motion 1: Electric height adjustment (26”–43”)\n\n Motion 2: Electric Trendelenburg tilt (+15°/-11°)\n\n Motion 3: Electric longitudinal travel (10”)\n\n Motion 4: Electric lateral tilt (±15°)\n\n All functions are controlled via a hand control (foot control optional).\n\n Table includes 2” radiolucent comfort foam pad, locking casters, patient restraint straps,\n\nand crescent face rest pad (with integrated headrest).\n\nRadiolucency:\n\n Carbon fiber construction ensures full radiolucency for unobstructed imaging during\n\nfluoroscopy.\n\n The table and accessories are designed to minimize imaging artifacts and maximize\n\nvisualization of cervical, thoracic, and lumbar regions.\n\nSafety, Compliance, and Warranty\n\n FDA listed, CE marked, cETLus listed, CB Certificate\n\n Warranty: 4 years parts, 3 years labor\n\n Safety features include locking casters and patient restraint straps\n\nMade in USA Compliance\n\n Vendors must provide written certification of country of origin and compliance with Buy\n\nAmerican Act requirements","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25526Q0562","place_of_performance":{"zip":"66048","city":{"code":"39000","name":"Leavenworth"},"state":{"code":"KS","name":"Kansas"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6515"}],"due_at":"2026-08-10T16:00:00Z","due_date":"2026-08-10","closes_at":"2026-08-10T16:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","state":"KS","county":"20103","county_name":"Leavenworth County","city":"2039000","city_name":"Leavenworth","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-27T01:17:22.261662Z","principal_notice_id":"dea1e42824b64837867f5014ccec132b","description":{"text":"Eastern Kansas\n\nStatement of Work: 4 Motion C-Arm Imaging Table\n\nThe purpose of this document is to provide a statement of work (SOW), for two 4 Motion C-Arm\n\nImaging Tables, one for each VA Eastern Kansas campus to be utilized by surgical staff. The\n\nImaging Tables have a large height range helping to create safe patient transfers while allowing\n\ndoctors to stand comfortably. The large lifting column is very rigid, ensuring rock solid support\n\nfor fast imaging and procedures.\n\nThe station requires two FDA-listed, CE-marked, electrically motorized C-Arm imaging tables for\n\npain management and surgical procedures. The tables must support safe patient transfers,\n\nprecise imaging, and stable positioning for both fluoroscopy and ultrasound-guided\n\ninterventions. The tables must be compatible with mobile C-Arm systems and support a wide\n\nrange of patient sizes and procedural requirements.\n\nA C-Arm is a mobile fluoroscopy imaging system shaped like the letter “C,” allowing real-time Xray\n\nimaging during procedures. The C-Arm rotates around the patient to provide multiple views\n\n(lateral, oblique, anteroposterior) without repositioning the patient. The CFPM400 table’s\n\nradiolucent design and metal-free imaging space ensure the C-Arm can capture clear images of\n\nthe spine and target anatomy in any projection. The table’s adjustable movements allow optimal\n\npositioning for both the patient and the C-Arm, supporting safe and efficient image-guided\n\ninterventions.\n\nObjectives:\n\n• Improve patient comfort during imaging and procedures.\n\n• Enhance the stability, precision imaging and procedures.\n\n• Increase operational efficiency in the surgical departments.\n\nRequirements (shall meet or exceed):\n\nTechnical Specifications:\n\n• Integrated Headrest Top: 22” (56cm) wide x 84” (214cm) long\n\n• Rectangular Top: 24” (61cm) wide x 80” (203cm) long\n\nSources Sought Notice\n\nSources Sought Notice\n\nPage 5 of 5\n\n• Imaging Space:\n\n• 56” metal-free imaging space (no obstructions for C-Arm imaging)\n\n• Height Range:\n\n• Electric height adjustment from 26” to 43” (CFPM400)\n\n• Weight capacity: 500 lb (227kg)\n\n• Product weight: 475 lb (216kg)\n\nMovements & Controls:\n\n Motion 1: Electric height adjustment (26”–43”)\n\n Motion 2: Electric Trendelenburg tilt (+15°/-11°)\n\n Motion 3: Electric longitudinal travel (10”)\n\n Motion 4: Electric lateral tilt (±15°)\n\n All functions are controlled via a hand control (foot control optional).\n\n Table includes 2” radiolucent comfort foam pad, locking casters, patient restraint straps,\n\nand crescent face rest pad (with integrated headrest).\n\nRadiolucency:\n\n Carbon fiber construction ensures full radiolucency for unobstructed imaging during\n\nfluoroscopy.\n\n The table and accessories are designed to minimize imaging artifacts and maximize\n\nvisualization of cervical, thoracic, and lumbar regions.\n\nSafety, Compliance, and Warranty\n\n FDA listed, CE marked, cETLus listed, CB Certificate\n\n Warranty: 4 years parts, 3 years labor\n\n Safety features include locking casters and patient restraint straps\n\nMade in USA Compliance\n\n Vendors must provide written certification of country of origin and compliance with Buy\n\nAmerican Act requirements","html":"<p>Eastern Kansas<br />\nStatement of Work: 4 Motion C-Arm Imaging Table<br />\nThe purpose of this document is to provide a statement of work (SOW), for two 4 Motion C-Arm<br />\nImaging Tables, one for each VA Eastern Kansas campus to be utilized by surgical staff. The<br />\nImaging Tables have a large height range helping to create safe patient transfers while allowing<br />\ndoctors to stand comfortably. The large lifting column is very rigid, ensuring rock solid support<br />\nfor fast imaging and procedures.<br />\nThe station requires two FDA-listed, CE-marked, electrically motorized C-Arm imaging tables for<br />\npain management and surgical procedures. The tables must support safe patient transfers,<br />\nprecise imaging, and stable positioning for both fluoroscopy and ultrasound-guided<br />\ninterventions. The tables must be compatible with mobile C-Arm systems and support a wide<br />\nrange of patient sizes and procedural requirements.<br />\nA C-Arm is a mobile fluoroscopy imaging system shaped like the letter &ldquo;C,&rdquo; allowing real-time Xray<br />\nimaging during procedures. The C-Arm rotates around the patient to provide multiple views<br />\n(lateral, oblique, anteroposterior) without repositioning the patient. The CFPM400 table&rsquo;s<br />\nradiolucent design and metal-free imaging space ensure the C-Arm can capture clear images of<br />\nthe spine and target anatomy in any projection. The table&rsquo;s adjustable movements allow optimal<br />\npositioning for both the patient and the C-Arm, supporting safe and efficient image-guided<br />\ninterventions.<br />\nObjectives:<br />\n&bull; Improve patient comfort during imaging and procedures.<br />\n&bull; Enhance the stability, precision imaging and procedures.<br />\n&bull; Increase operational efficiency in the surgical departments.<br />\nRequirements (shall meet or exceed):<br />\nTechnical Specifications:<br />\n&bull; Integrated Headrest Top: 22&rdquo; (56cm) wide x 84&rdquo; (214cm) long<br />\n&bull; Rectangular Top: 24&rdquo; (61cm) wide x 80&rdquo; (203cm) long<br />\nSources Sought Notice<br />\nSources Sought Notice<br />\nPage 5 of 5<br />\n&bull; Imaging Space:<br />\n&bull; 56&rdquo; metal-free imaging space (no obstructions for C-Arm imaging)<br />\n&bull; Height Range:<br />\n&bull; Electric height adjustment from 26&rdquo; to 43&rdquo; (CFPM400)<br />\n&bull; Weight capacity: 500 lb (227kg)<br />\n&bull; Product weight: 475 lb (216kg)<br />\nMovements &amp; Controls:<br />\n Motion 1: Electric height adjustment (26&rdquo;&ndash;43&rdquo;)<br />\n Motion 2: Electric Trendelenburg tilt (+15&deg;/-11&deg;)<br />\n Motion 3: Electric longitudinal travel (10&rdquo;)<br />\n Motion 4: Electric lateral tilt (&plusmn;15&deg;)<br />\n All functions are controlled via a hand control (foot control optional).<br />\n Table includes 2&rdquo; radiolucent comfort foam pad, locking casters, patient restraint straps,<br />\nand crescent face rest pad (with integrated headrest).<br />\nRadiolucency:<br />\n Carbon fiber construction ensures full radiolucency for unobstructed imaging during<br />\nfluoroscopy.<br />\n The table and accessories are designed to minimize imaging artifacts and maximize<br />\nvisualization of cervical, thoracic, and lumbar regions.<br />\nSafety, Compliance, and Warranty<br />\n FDA listed, CE marked, cETLus listed, CB Certificate<br />\n Warranty: 4 years parts, 3 years labor<br />\n Safety features include locking casters and patient restraint straps<br />\nMade in USA Compliance<br />\n Vendors must provide written certification of country of origin and compliance with Buy<br />\nAmerican Act requirements</p>","origin":"detail"},"contacts":[{"name":"Jon Lutmer","role":"primary","email":"Jonathan.lutmer@va.gov","phone":"4104463862"}],"place_of_performance":{"zip":"66048","city":{"code":"39000","name":"Leavenworth"},"state":{"code":"KS","name":"Kansas"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"66048","city":"LEAVENWORTH","state":"KS","country":"USA"},"naics_codes":["339113"],"award":null,"attachments":[{"resource_id":"9a34fca44bbe4e0c9d0a0e1820e11ea9","name":"36C25526Q0562.pdf","kind":"file","mime_type":".pdf","size_bytes":129658,"posted_at":"2026-08-03T20:10:49.882Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/9a34fca44bbe4e0c9d0a0e1820e11ea9/download","mirrored":false}],"awards":[],"related":[{"key":"36C25527R0016","latest_notice_id":"a7eee67b427c47158525b1a79fc8ecd2","title":"Z2DA--657-24-102JC - Prepare Site for New PET/CT, Room A011D (MD) FY27 NRM VISN Base, CON (VA-27-00017492) 657-27-1-8434-0001","solicitation_number":"36C25527R0016","notice_type":"p","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"236220","psc":"Z2DA","set_aside":"SDVOSBC","state":"MO","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"WORK: THE GENERAL DESCRIPTION: VA SAINT LOUIS HEALTH CARE SYSTEM","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C25526Q0617","latest_notice_id":"3506983a2af048deaf442eae0f8b8a04","title":"H112--Annual/Sem-i annual fire smoke inspections and auto door services l EKH","solicitation_number":"36C25526Q0617","notice_type":"o","first_type":"r","first_posted":"2026-08-19","last_posted":"2026-11-18","notices":11,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"541350","psc":"H112","set_aside":"SBA","state":"KS","county":"20103","county_name":"Leavenworth County","city":"2039000","city_name":"Leavenworth","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C25527Q0057","latest_notice_id":"fbd76a4c366d45e896674756383b4fb2","title":"C222--589-27-108, Correct Electrical Deficiencies in Building 26 KCVA (ME) FY27 NRM VISN Base - AE (VA-27-00021035)","solicitation_number":"36C25527Q0057","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":2,"due_at":"2026-12-01T20:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"541330","psc":"C222","set_aside":"EDWOSB","state":"MO","county":"29095","county_name":"Jackson County","city":"2938000","city_name":"Kansas City","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T09:15:14.204648Z"},{"key":"36C25527Q00571","latest_notice_id":"53c5d2376d9e4fb79d39a712a62deb10","title":"C222--589-27-108, Correct Electrical Deficiencies in Building 26 KCVA (ME) FY27 NRM VISN Base - AE (VA-27-00021035)","solicitation_number":"36C25527Q0057_1","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-12-01T20:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"541330","psc":"C222","set_aside":"SDVOSBC","state":"MO","county":"29095","county_name":"Jackson County","city":"2938000","city_name":"Kansas City","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C25527Q0053","latest_notice_id":"f87b14f3ce2643d69bdc633c0b05a712","title":"J065--Imaging Service & Maintenance EHCC & MTV","solicitation_number":"36C25527Q0053","notice_type":"o","first_type":"p","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":2,"due_at":"2026-12-02T14:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"811210","psc":"J065","set_aside":null,"state":"IN","county":"18163","county_name":"Vanderburgh County","city":"1822000","city_name":"Evansville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open":[{"key":"36C26027Q0130","latest_notice_id":"865639d03bae440aaa4a2e2195e0abf9","title":"6515--SOURCES SOUGHT NOTICE FOR HEAD, SHOULDER, AND UPPER-EXTREMITY POSITIONING ACCESSORIES FOR THE MAQUET MEERA 7200 OPERATING TABLE","solicitation_number":"36C26027Q0130","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":2,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"339113","psc":"6515","set_aside":null,"state":"WA","county":"53063","county_name":"Spokane County","city":"5367000","city_name":"Spokane","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"N0010427QLA17","latest_notice_id":"5958ba02b5c94595a30747ebb8d1c461","title":"VALVE,BREATHING APP","solicitation_number":"N0010427QLA17","notice_type":"o","first_type":"o","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-27T20:30:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"339113","psc":"4240","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"IN THE SCHEDULE. ^^ \"ALL FREIGHT IS FOB ORIGIN","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"36C25727Q0104","latest_notice_id":"9c3ddb4326164d4fa71ad956d4194f7c","title":"6515--36C257-27-AP-0953 Prosthetic STX 671 O2 Equipment (VA-27-00016458)","solicitation_number":"36C25727Q0104","notice_type":"o","first_type":"p","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":3,"due_at":"2026-11-30T19:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"339113","psc":"6515","set_aside":"SDVOSBC","state":"TX","county":"48029","county_name":"Bexar County","city":"4865000","city_name":"San Antonio","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":20,"indexable":false}