{"canonical":"https://sealedbidder.com/opportunities/36c25526q0487","key":"36C25526Q0487","url":"https://sealedbidder.com/opportunities/36c25526q0487","title":"6525--Dental Imaging Equipment- 3D X-Ray Unit","solicitation_number":"36C25526Q0487","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-07-10T13:00:00Z","first_posted":"2026-06-30","last_posted":"2026-06-30","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"339114","psc":"6525","set_aside":null,"place_state":null,"place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":"Product purchase (PSC 6525)","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"bd34c5e551bf46ae83a11f1665141f92","title":"6525--Dental Imaging Equipment- 3D X-Ray Unit","solicitation_number":"36C25526Q0487","notice_type":"r","base_type":"r","posted":"2026-06-30","posted_at":"2026-06-30T20:04:39.508Z","due_at":"2026-07-10T13:00:00Z","due_date":"2026-07-10","cancelled":false,"archived":true,"archive_date":"2026-07-20","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/bd34c5e551bf46ae83a11f1665141f92/view","enriched":true,"history":[{"index":3,"title":"6525--Dental Imaging Equipment- 3D X-Ray Unit","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-30T20:04:39.508Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"bd34c5e551bf46ae83a11f1665141f92","solicitation_number":"36C25526Q0487"}]}],"latest_notice_id":"bd34c5e551bf46ae83a11f1665141f92","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-06-30","posted_at":"2026-06-30T20:04:39.508Z","created_at":"2026-06-30T20:04:37.246Z","modified_at":"2026-07-21T03:55:45.638Z","response_deadline":{"raw":"2026-07-10T08:00:00-05:00","utc":"2026-07-10T13:00:00Z","date":"2026-07-10","time":"08:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/bd34c5e551bf46ae83a11f1665141f92/view"},"naics":{"codes":["339114"],"primary":"339114"},"title":"6525--Dental Imaging Equipment- 3D X-Ray Unit","agency":{"office":{"code":"36C255","name":"255-NETWORK CONTRACT OFFICE 15 (36C255)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"66048","city":"LEAVENWORTH","state":"KS","country":"USA"},"organization_id":"100186523","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-07-20","archive_type":"auto_custom"},"history":[{"index":3,"title":"6525--Dental Imaging Equipment- 3D X-Ray Unit","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-30T20:04:39.508Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"bd34c5e551bf46ae83a11f1665141f92","solicitation_number":"36C25526Q0487"}],"contacts":[{"name":"Tracie Raggs","role":"primary","email":"tracie.raggs@va.gov","phone":"913-946-1985","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"bd34c5e551bf46ae83a11f1665141f92","lineage_id":"bd34c5e551bf46ae83a11f1665141f92","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-30T14:48:32.000282599Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"2722149d954483ff08e2dba15f6010b560eea3ae2a282b58285f31e6a068fc68","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-30T14:48:32.000282599Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT\n\nDISCLAIMER\n\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\n\nThe submission of pricing, capabilities for planning purposes, and other market information is highly encouraged and allowed under this RFI In Accordance With (IAW) FAR Part 15.201(e).\n\nSOURCES SOUGHT DESCRIPTION\n\nThis is NOT a solicitation announcement. This is a RFI/sources sought only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 339114 (size standard of 750 Employees). Responses to this sources sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought, a solicitation announcement may be published. Responses to this sources sought synopsis are not considered adequate responses for a solicitation announcement. \n\nThe Department of Veterans Affairs (VA), VISN 15 Network Contracting Office, is seeking sources that can provide the following,:\nRequirements: \n\nJSN\nNomenclature\nQuantity\nU0022\nDental Imaging Software License Expansion\n1\nX6500\nX-Ray Unit, Dental, 3D\n1\nX6600\nRadiographic Unit, Dental, Wall Mounted, 7 mA\n7\nX6610\nSensor Kit, Dental Imaging System, Size 1 & Size 2\n7\n\nSpecifications: \n\nDental Imaging Software License Expansion:\nSoftware License must be included for 3D imaging machine to have the ability to communicate between the machine and VA computers.\nX-Ray Unit, Dental, 3D:\nThe system shall be a Cone Beam Computed Tomography (CBCT) imaging system capable of performing 2D panoramic, 3D CBCT, and optional cephalometric imaging for dental, oral surgery, endodontic, orthodontic, and maxillofacial applications. System shall be new, current production model.\nImaging Capabilities\nMust provide:\n2D digital panoramic imaging\n3D CBCT imaging\nOptional cephalometric imaging capability (expandable or integrated)\nField of View (FOV) options ranging from small focused volumes (~5x5 cm) up to large craniofacial volumes (~16x17 cm or equivalent).\nHigh-resolution imaging with voxel sizes as small as 75-150 Âµm (or better).\nAdjustable FOV selection to limit patient radiation exposure.\nMetal artifact reduction (MAR) or equivalent technology.\nDetector & Image Quality\nFlat panel digital detector technology.\nHigh-contrast resolution suitable for:\nImplant planning\nEndodontic diagnosis\nTMJ evaluation\nAirway analysis\nGrayscale depth minimum 14-bit or equivalent.\nAutomatic exposure control or programmable exposure settings.\nSoftware & Workflow\nManufacturer-provided imaging software included.\nSoftware shall support:\nImplant planning tools\nNerve tracing\nAirway measurement\nTMJ analysis\nEndodontic assessment\nDICOM 3.0 compliant.\nIntegration capability with PACS and third-party practice management systems.\n3D rendering and multiplanar reconstruction (MPR).\nExport capability in STL format for surgical guides.\nPatient Positioning & Ergonomics\nOpen-face design or patient-friendly configuration.\nPositioning guides (minimum three planes).\nAdjustable chin rest, head supports, and temple supports.\nMotorized height adjustment.\nAccommodates standing and seated (wheelchair accessible) patients.\nTouchscreen interface mounted on unit.\nPower: 110-240V, 50/60Hz.\nCompatible with standard dental operatory electrical infrastructure.\nNetwork connectivity via Ethernet\nRadiographic Unit, Dental, Wall Mounted, 7mA\nThe system shall be a wall-mounted intraoral dental X-ray unit with extended reach (long arm configuration) for use in general dentistry, oral surgery, and specialty dental clinics. \nImaging Performance\nHigh-frequency DC X-ray generator.\nConstant potential output for consistent image quality.\nTube voltage approximately 60-70 kVp.\nTube current approximately 7 mA (or equivalent).\nExposure time range suitable for digital sensors and phosphor plates.\nCompatible with:\nDigital intraoral sensors\nTraditional film\nRectangular collimation capability (preferred) to reduce patient dose.\nFocal spot size approximately 0.7 mm or smaller.\nLong Arm Configuration\nExtended arm reach minimum 81 inches (or equivalent).\nDouble-articulating arm for flexible positioning.\nSmooth, drift-free positioning.\nStable tube head that maintains selected position without sag.\nWall-mounted installation with appropriate structural support requirements provided.\nLong arm shall accommodate large operatories and specialty treatment rooms.\nControl & Interface\nWall-mounted control panel.\nProgrammable exposure presets for:\nAdult anterior/posterior\nPediatric anterior/posterior\nDigital display for exposure time.\nManual exposure adjustment capability.\nError codes or diagnostic display.\nSafety & Radiation Protection\nCompliance with FDA and NCRP radiation standards.\nMinimum total filtration equivalent to 2.5 mm aluminum at 70 kVp.\nDead-man type exposure switch.\nMinimum source-to-skin distance compliant with federal standards.\nAudible and visual exposure indicators.\nLeakage radiation within regulatory limits.\nMechanical & Ergonomic Features\nLightweight tube head.\n360-degree rotational capability at arm and tube head joints.\nSmooth, low-resistance movement.\nSealed, oil-cooled X-ray tube housing.\nEasy-to-clean surfaces suitable for clinical infection control.\nElectrical Requirements\nStandard 110-120V electrical service.\nCompatible with standard dental operatory electrical infrastructure.\nLine voltage regulation to ensure stable output.\nSensor Kit, Dental Imaging System, Size 1 & Size 2 \nThe system shall consist of direct digital intraoral radiography sensors, Size 1 and Size 2, compatible with standard intraoral dental X-ray generators. Sensors shall be new, current production models designed for high-resolution diagnostic imaging in general dentistry and specialty dental clinics.\nSensor Technology\nCMOS or equivalent digital sensor technology.\nTrue resolution minimum 20 line pairs/mm (or equivalent high-resolution performance).\nTheoretical resolution up to 24 lp/mm (or equivalent).\nPixel size approximately 19-20 Âµm (or better).\nActive imaging area optimized for diagnostic accuracy.\nMust include:\nSize 1 (Pediatric/Anterior)\nActive area approximately 20 x 30 mm (or equivalent).\nSlim profile for patient comfort.\nRounded corners for intraoral comfort.\nSize 2 (Adult/Posterior Standard)\nActive area approximately 26 x 36 mm (or equivalent).\nStandard adult posterior imaging size.\nErgonomic shape for ease of positioning.\nImage Quality & Performance\nHigh contrast resolution suitable for:\nCaries detection\nEndodontic evaluation\nPeriapical imaging\nPeriodontal assessment\nWide dynamic range.\nNoise reduction capability.\nAutomatic exposure detection.\nCompatible with standard 60-70 kVp intraoral X-ray units.\nDurability & Construction\nShock-resistant housing.\nReinforced cable attachment.\nCable length minimum 2 meters (or equivalent).\nWater-resistant and disinfectant-resistant outer casing.\nIP rating suitable for clinical dental environments.\nSensor thickness designed to enhance patient comfort.\nSoftware & Integration\nManufacturer-provided imaging software included or compatible.\nTWAIN and DICOM compliant.\nCompatible with:\nPACS systems\nDental imaging software platforms\nPractice management systems\nUSB connectivity.\nPlug-and-play configuration.\nInfection Control\nCompatible with standard disposable sensor barriers.\nSmooth, sealed housing for disinfection.\nManufacturer-recommended cleaning protocols provided.\nElectrical & Technical Requirements\nUSB 2.0 or higher connectivity.\nCompatible with Windows-based acquisition workstations.\n\nThe information identified above are intended to be descriptive, not restrictive, and to indicate the quality of the supplies that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications.\n\nIf you are interested and are capable of providing the sought-out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: \n\nPlease indicate the size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)?\n\n\nIs your company considered small under the NAICS code identified under this RFI?\n\n\n\nAre you the manufacturer, an authorized distributor, or an equivalent solution to the items being referenced above? If an authorized distributor must provide proof.\n\n\n\nIf you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, are you providing the equipment from a small business manufacturer?\n\n\nDo you alter, assemble, or modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\n\n\n\nDoes your company have an FSS contract with GSA, VA NAC, NASA SEWP, or any other federal contract, that can be utilized to procure the requirement listed above? If so, please provide the contract number.\n\n\n\nWhere is the product manufactured?\n\n\nPlease submit your capabilities that show clear, compelling, and convincing evidence that you can meet the requirement described in the attached SOW. \n\n\n\nPlease provide your UEI number.\n\n\nResponses to this notice shall be submitted via email to Tracie Raggs at tracie.raggs@va.gov. Telephone responses shall not be accepted. Responses must be received no later than Friday, July 10, 2026, at 0800 CST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this sources sought. Responses to this sources sought notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation","text":"THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT\n\nDISCLAIMER\n\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\n\nThe submission of pricing, capabilities for planning purposes, and other market information is highly encouraged and allowed under this RFI In Accordance With (IAW) FAR Part 15.201(e).\n\nSOURCES SOUGHT DESCRIPTION\n\nThis is NOT a solicitation announcement. This is a RFI/sources sought only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 339114 (size standard of 750 Employees). Responses to this sources sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought, a solicitation announcement may be published. Responses to this sources sought synopsis are not considered adequate responses for a solicitation announcement.\n\nThe Department of Veterans Affairs (VA), VISN 15 Network Contracting Office, is seeking sources that can provide the following,:\nRequirements:\n\nJSN\nNomenclature\nQuantity\nU0022\nDental Imaging Software License Expansion\n1\nX6500\nX-Ray Unit, Dental, 3D\n1\nX6600\nRadiographic Unit, Dental, Wall Mounted, 7 mA\n7\nX6610\nSensor Kit, Dental Imaging System, Size 1 & Size 2\n7\n\nSpecifications:\n\nDental Imaging Software License Expansion:\nSoftware License must be included for 3D imaging machine to have the ability to communicate between the machine and VA computers.\nX-Ray Unit, Dental, 3D:\nThe system shall be a Cone Beam Computed Tomography (CBCT) imaging system capable of performing 2D panoramic, 3D CBCT, and optional cephalometric imaging for dental, oral surgery, endodontic, orthodontic, and maxillofacial applications. System shall be new, current production model.\nImaging Capabilities\nMust provide:\n2D digital panoramic imaging\n3D CBCT imaging\nOptional cephalometric imaging capability (expandable or integrated)\nField of View (FOV) options ranging from small focused volumes (~5x5 cm) up to large craniofacial volumes (~16x17 cm or equivalent).\nHigh-resolution imaging with voxel sizes as small as 75-150 Âµm (or better).\nAdjustable FOV selection to limit patient radiation exposure.\nMetal artifact reduction (MAR) or equivalent technology.\nDetector & Image Quality\nFlat panel digital detector technology.\nHigh-contrast resolution suitable for:\nImplant planning\nEndodontic diagnosis\nTMJ evaluation\nAirway analysis\nGrayscale depth minimum 14-bit or equivalent.\nAutomatic exposure control or programmable exposure settings.\nSoftware & Workflow\nManufacturer-provided imaging software included.\nSoftware shall support:\nImplant planning tools\nNerve tracing\nAirway measurement\nTMJ analysis\nEndodontic assessment\nDICOM 3.0 compliant.\nIntegration capability with PACS and third-party practice management systems.\n3D rendering and multiplanar reconstruction (MPR).\nExport capability in STL format for surgical guides.\nPatient Positioning & Ergonomics\nOpen-face design or patient-friendly configuration.\nPositioning guides (minimum three planes).\nAdjustable chin rest, head supports, and temple supports.\nMotorized height adjustment.\nAccommodates standing and seated (wheelchair accessible) patients.\nTouchscreen interface mounted on unit.\nPower: 110-240V, 50/60Hz.\nCompatible with standard dental operatory electrical infrastructure.\nNetwork connectivity via Ethernet\nRadiographic Unit, Dental, Wall Mounted, 7mA\nThe system shall be a wall-mounted intraoral dental X-ray unit with extended reach (long arm configuration) for use in general dentistry, oral surgery, and specialty dental clinics.\nImaging Performance\nHigh-frequency DC X-ray generator.\nConstant potential output for consistent image quality.\nTube voltage approximately 60-70 kVp.\nTube current approximately 7 mA (or equivalent).\nExposure time range suitable for digital sensors and phosphor plates.\nCompatible with:\nDigital intraoral sensors\nTraditional film\nRectangular collimation capability (preferred) to reduce patient dose.\nFocal spot size approximately 0.7 mm or smaller.\nLong Arm Configuration\nExtended arm reach minimum 81 inches (or equivalent).\nDouble-articulating arm for flexible positioning.\nSmooth, drift-free positioning.\nStable tube head that maintains selected position without sag.\nWall-mounted installation with appropriate structural support requirements provided.\nLong arm shall accommodate large operatories and specialty treatment rooms.\nControl & Interface\nWall-mounted control panel.\nProgrammable exposure presets for:\nAdult anterior/posterior\nPediatric anterior/posterior\nDigital display for exposure time.\nManual exposure adjustment capability.\nError codes or diagnostic display.\nSafety & Radiation Protection\nCompliance with FDA and NCRP radiation standards.\nMinimum total filtration equivalent to 2.5 mm aluminum at 70 kVp.\nDead-man type exposure switch.\nMinimum source-to-skin distance compliant with federal standards.\nAudible and visual exposure indicators.\nLeakage radiation within regulatory limits.\nMechanical & Ergonomic Features\nLightweight tube head.\n360-degree rotational capability at arm and tube head joints.\nSmooth, low-resistance movement.\nSealed, oil-cooled X-ray tube housing.\nEasy-to-clean surfaces suitable for clinical infection control.\nElectrical Requirements\nStandard 110-120V electrical service.\nCompatible with standard dental operatory electrical infrastructure.\nLine voltage regulation to ensure stable output.\nSensor Kit, Dental Imaging System, Size 1 & Size 2\nThe system shall consist of direct digital intraoral radiography sensors, Size 1 and Size 2, compatible with standard intraoral dental X-ray generators. Sensors shall be new, current production models designed for high-resolution diagnostic imaging in general dentistry and specialty dental clinics.\nSensor Technology\nCMOS or equivalent digital sensor technology.\nTrue resolution minimum 20 line pairs/mm (or equivalent high-resolution performance).\nTheoretical resolution up to 24 lp/mm (or equivalent).\nPixel size approximately 19-20 Âµm (or better).\nActive imaging area optimized for diagnostic accuracy.\nMust include:\nSize 1 (Pediatric/Anterior)\nActive area approximately 20 x 30 mm (or equivalent).\nSlim profile for patient comfort.\nRounded corners for intraoral comfort.\nSize 2 (Adult/Posterior Standard)\nActive area approximately 26 x 36 mm (or equivalent).\nStandard adult posterior imaging size.\nErgonomic shape for ease of positioning.\nImage Quality & Performance\nHigh contrast resolution suitable for:\nCaries detection\nEndodontic evaluation\nPeriapical imaging\nPeriodontal assessment\nWide dynamic range.\nNoise reduction capability.\nAutomatic exposure detection.\nCompatible with standard 60-70 kVp intraoral X-ray units.\nDurability & Construction\nShock-resistant housing.\nReinforced cable attachment.\nCable length minimum 2 meters (or equivalent).\nWater-resistant and disinfectant-resistant outer casing.\nIP rating suitable for clinical dental environments.\nSensor thickness designed to enhance patient comfort.\nSoftware & Integration\nManufacturer-provided imaging software included or compatible.\nTWAIN and DICOM compliant.\nCompatible with:\nPACS systems\nDental imaging software platforms\nPractice management systems\nUSB connectivity.\nPlug-and-play configuration.\nInfection Control\nCompatible with standard disposable sensor barriers.\nSmooth, sealed housing for disinfection.\nManufacturer-recommended cleaning protocols provided.\nElectrical & Technical Requirements\nUSB 2.0 or higher connectivity.\nCompatible with Windows-based acquisition workstations.\n\nThe information identified above are intended to be descriptive, not restrictive, and to indicate the quality of the supplies that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications.\n\nIf you are interested and are capable of providing the sought-out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:\n\nPlease indicate the size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)?\n\nIs your company considered small under the NAICS code identified under this RFI?\n\nAre you the manufacturer, an authorized distributor, or an equivalent solution to the items being referenced above? If an authorized distributor must provide proof.\n\nIf you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, are you providing the equipment from a small business manufacturer?\n\nDo you alter, assemble, or modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\n\nDoes your company have an FSS contract with GSA, VA NAC, NASA SEWP, or any other federal contract, that can be utilized to procure the requirement listed above? If so, please provide the contract number.\n\nWhere is the product manufactured?\n\nPlease submit your capabilities that show clear, compelling, and convincing evidence that you can meet the requirement described in the attached SOW.\n\nPlease provide your UEI number.\n\nResponses to this notice shall be submitted via email to Tracie Raggs at tracie.raggs@va.gov. Telephone responses shall not be accepted. Responses must be received no later than Friday, July 10, 2026, at 0800 CST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this sources sought. Responses to this sources sought notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25526Q0487","place_of_performance":{"zip":"65401","city":{"name":"Rolla"},"state":{"name":"MO"},"street":"Rolla Community Based Outpatient Clinic (CBOC)","country":{"code":"USA","name":"UNITED STATES"},"street2":"13063 Old Wire Rd"},"product_service_code":"6525"}],"due_at":"2026-07-10T13:00:00Z","due_date":"2026-07-10","closes_at":"2026-07-10T13:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":"Product purchase (PSC 6525)","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-30T15:43:22.210154Z","principal_notice_id":"bd34c5e551bf46ae83a11f1665141f92","description":{"text":"THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT\n\nDISCLAIMER\n\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\n\nThe submission of pricing, capabilities for planning purposes, and other market information is highly encouraged and allowed under this RFI In Accordance With (IAW) FAR Part 15.201(e).\n\nSOURCES SOUGHT DESCRIPTION\n\nThis is NOT a solicitation announcement. This is a RFI/sources sought only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 339114 (size standard of 750 Employees). Responses to this sources sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought, a solicitation announcement may be published. Responses to this sources sought synopsis are not considered adequate responses for a solicitation announcement.\n\nThe Department of Veterans Affairs (VA), VISN 15 Network Contracting Office, is seeking sources that can provide the following,:\nRequirements:\n\nJSN\nNomenclature\nQuantity\nU0022\nDental Imaging Software License Expansion\n1\nX6500\nX-Ray Unit, Dental, 3D\n1\nX6600\nRadiographic Unit, Dental, Wall Mounted, 7 mA\n7\nX6610\nSensor Kit, Dental Imaging System, Size 1 & Size 2\n7\n\nSpecifications:\n\nDental Imaging Software License Expansion:\nSoftware License must be included for 3D imaging machine to have the ability to communicate between the machine and VA computers.\nX-Ray Unit, Dental, 3D:\nThe system shall be a Cone Beam Computed Tomography (CBCT) imaging system capable of performing 2D panoramic, 3D CBCT, and optional cephalometric imaging for dental, oral surgery, endodontic, orthodontic, and maxillofacial applications. System shall be new, current production model.\nImaging Capabilities\nMust provide:\n2D digital panoramic imaging\n3D CBCT imaging\nOptional cephalometric imaging capability (expandable or integrated)\nField of View (FOV) options ranging from small focused volumes (~5x5 cm) up to large craniofacial volumes (~16x17 cm or equivalent).\nHigh-resolution imaging with voxel sizes as small as 75-150 Âµm (or better).\nAdjustable FOV selection to limit patient radiation exposure.\nMetal artifact reduction (MAR) or equivalent technology.\nDetector & Image Quality\nFlat panel digital detector technology.\nHigh-contrast resolution suitable for:\nImplant planning\nEndodontic diagnosis\nTMJ evaluation\nAirway analysis\nGrayscale depth minimum 14-bit or equivalent.\nAutomatic exposure control or programmable exposure settings.\nSoftware & Workflow\nManufacturer-provided imaging software included.\nSoftware shall support:\nImplant planning tools\nNerve tracing\nAirway measurement\nTMJ analysis\nEndodontic assessment\nDICOM 3.0 compliant.\nIntegration capability with PACS and third-party practice management systems.\n3D rendering and multiplanar reconstruction (MPR).\nExport capability in STL format for surgical guides.\nPatient Positioning & Ergonomics\nOpen-face design or patient-friendly configuration.\nPositioning guides (minimum three planes).\nAdjustable chin rest, head supports, and temple supports.\nMotorized height adjustment.\nAccommodates standing and seated (wheelchair accessible) patients.\nTouchscreen interface mounted on unit.\nPower: 110-240V, 50/60Hz.\nCompatible with standard dental operatory electrical infrastructure.\nNetwork connectivity via Ethernet\nRadiographic Unit, Dental, Wall Mounted, 7mA\nThe system shall be a wall-mounted intraoral dental X-ray unit with extended reach (long arm configuration) for use in general dentistry, oral surgery, and specialty dental clinics.\nImaging Performance\nHigh-frequency DC X-ray generator.\nConstant potential output for consistent image quality.\nTube voltage approximately 60-70 kVp.\nTube current approximately 7 mA (or equivalent).\nExposure time range suitable for digital sensors and phosphor plates.\nCompatible with:\nDigital intraoral sensors\nTraditional film\nRectangular collimation capability (preferred) to reduce patient dose.\nFocal spot size approximately 0.7 mm or smaller.\nLong Arm Configuration\nExtended arm reach minimum 81 inches (or equivalent).\nDouble-articulating arm for flexible positioning.\nSmooth, drift-free positioning.\nStable tube head that maintains selected position without sag.\nWall-mounted installation with appropriate structural support requirements provided.\nLong arm shall accommodate large operatories and specialty treatment rooms.\nControl & Interface\nWall-mounted control panel.\nProgrammable exposure presets for:\nAdult anterior/posterior\nPediatric anterior/posterior\nDigital display for exposure time.\nManual exposure adjustment capability.\nError codes or diagnostic display.\nSafety & Radiation Protection\nCompliance with FDA and NCRP radiation standards.\nMinimum total filtration equivalent to 2.5 mm aluminum at 70 kVp.\nDead-man type exposure switch.\nMinimum source-to-skin distance compliant with federal standards.\nAudible and visual exposure indicators.\nLeakage radiation within regulatory limits.\nMechanical & Ergonomic Features\nLightweight tube head.\n360-degree rotational capability at arm and tube head joints.\nSmooth, low-resistance movement.\nSealed, oil-cooled X-ray tube housing.\nEasy-to-clean surfaces suitable for clinical infection control.\nElectrical Requirements\nStandard 110-120V electrical service.\nCompatible with standard dental operatory electrical infrastructure.\nLine voltage regulation to ensure stable output.\nSensor Kit, Dental Imaging System, Size 1 & Size 2\nThe system shall consist of direct digital intraoral radiography sensors, Size 1 and Size 2, compatible with standard intraoral dental X-ray generators. Sensors shall be new, current production models designed for high-resolution diagnostic imaging in general dentistry and specialty dental clinics.\nSensor Technology\nCMOS or equivalent digital sensor technology.\nTrue resolution minimum 20 line pairs/mm (or equivalent high-resolution performance).\nTheoretical resolution up to 24 lp/mm (or equivalent).\nPixel size approximately 19-20 Âµm (or better).\nActive imaging area optimized for diagnostic accuracy.\nMust include:\nSize 1 (Pediatric/Anterior)\nActive area approximately 20 x 30 mm (or equivalent).\nSlim profile for patient comfort.\nRounded corners for intraoral comfort.\nSize 2 (Adult/Posterior Standard)\nActive area approximately 26 x 36 mm (or equivalent).\nStandard adult posterior imaging size.\nErgonomic shape for ease of positioning.\nImage Quality & Performance\nHigh contrast resolution suitable for:\nCaries detection\nEndodontic evaluation\nPeriapical imaging\nPeriodontal assessment\nWide dynamic range.\nNoise reduction capability.\nAutomatic exposure detection.\nCompatible with standard 60-70 kVp intraoral X-ray units.\nDurability & Construction\nShock-resistant housing.\nReinforced cable attachment.\nCable length minimum 2 meters (or equivalent).\nWater-resistant and disinfectant-resistant outer casing.\nIP rating suitable for clinical dental environments.\nSensor thickness designed to enhance patient comfort.\nSoftware & Integration\nManufacturer-provided imaging software included or compatible.\nTWAIN and DICOM compliant.\nCompatible with:\nPACS systems\nDental imaging software platforms\nPractice management systems\nUSB connectivity.\nPlug-and-play configuration.\nInfection Control\nCompatible with standard disposable sensor barriers.\nSmooth, sealed housing for disinfection.\nManufacturer-recommended cleaning protocols provided.\nElectrical & Technical Requirements\nUSB 2.0 or higher connectivity.\nCompatible with Windows-based acquisition workstations.\n\nThe information identified above are intended to be descriptive, not restrictive, and to indicate the quality of the supplies that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications.\n\nIf you are interested and are capable of providing the sought-out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:\n\nPlease indicate the size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)?\n\nIs your company considered small under the NAICS code identified under this RFI?\n\nAre you the manufacturer, an authorized distributor, or an equivalent solution to the items being referenced above? If an authorized distributor must provide proof.\n\nIf you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, are you providing the equipment from a small business manufacturer?\n\nDo you alter, assemble, or modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\n\nDoes your company have an FSS contract with GSA, VA NAC, NASA SEWP, or any other federal contract, that can be utilized to procure the requirement listed above? If so, please provide the contract number.\n\nWhere is the product manufactured?\n\nPlease submit your capabilities that show clear, compelling, and convincing evidence that you can meet the requirement described in the attached SOW.\n\nPlease provide your UEI number.\n\nResponses to this notice shall be submitted via email to Tracie Raggs at tracie.raggs@va.gov. Telephone responses shall not be accepted. Responses must be received no later than Friday, July 10, 2026, at 0800 CST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this sources sought. Responses to this sources sought notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation","html":"THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT\n\nDISCLAIMER\n\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\n\nThe submission of pricing, capabilities for planning purposes, and other market information is highly encouraged and allowed under this RFI In Accordance With (IAW) FAR Part 15.201(e).\n\nSOURCES SOUGHT DESCRIPTION\n\nThis is NOT a solicitation announcement. This is a RFI/sources sought only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 339114 (size standard of 750 Employees). Responses to this sources sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought, a solicitation announcement may be published. Responses to this sources sought synopsis are not considered adequate responses for a solicitation announcement. \n\nThe Department of Veterans Affairs (VA), VISN 15 Network Contracting Office, is seeking sources that can provide the following,:\nRequirements: \n\nJSN\nNomenclature\nQuantity\nU0022\nDental Imaging Software License Expansion\n1\nX6500\nX-Ray Unit, Dental, 3D\n1\nX6600\nRadiographic Unit, Dental, Wall Mounted, 7 mA\n7\nX6610\nSensor Kit, Dental Imaging System, Size 1 & Size 2\n7\n\nSpecifications: \n\nDental Imaging Software License Expansion:\nSoftware License must be included for 3D imaging machine to have the ability to communicate between the machine and VA computers.\nX-Ray Unit, Dental, 3D:\nThe system shall be a Cone Beam Computed Tomography (CBCT) imaging system capable of performing 2D panoramic, 3D CBCT, and optional cephalometric imaging for dental, oral surgery, endodontic, orthodontic, and maxillofacial applications. System shall be new, current production model.\nImaging Capabilities\nMust provide:\n2D digital panoramic imaging\n3D CBCT imaging\nOptional cephalometric imaging capability (expandable or integrated)\nField of View (FOV) options ranging from small focused volumes (~5x5 cm) up to large craniofacial volumes (~16x17 cm or equivalent).\nHigh-resolution imaging with voxel sizes as small as 75-150 Âµm (or better).\nAdjustable FOV selection to limit patient radiation exposure.\nMetal artifact reduction (MAR) or equivalent technology.\nDetector & Image Quality\nFlat panel digital detector technology.\nHigh-contrast resolution suitable for:\nImplant planning\nEndodontic diagnosis\nTMJ evaluation\nAirway analysis\nGrayscale depth minimum 14-bit or equivalent.\nAutomatic exposure control or programmable exposure settings.\nSoftware & Workflow\nManufacturer-provided imaging software included.\nSoftware shall support:\nImplant planning tools\nNerve tracing\nAirway measurement\nTMJ analysis\nEndodontic assessment\nDICOM 3.0 compliant.\nIntegration capability with PACS and third-party practice management systems.\n3D rendering and multiplanar reconstruction (MPR).\nExport capability in STL format for surgical guides.\nPatient Positioning & Ergonomics\nOpen-face design or patient-friendly configuration.\nPositioning guides (minimum three planes).\nAdjustable chin rest, head supports, and temple supports.\nMotorized height adjustment.\nAccommodates standing and seated (wheelchair accessible) patients.\nTouchscreen interface mounted on unit.\nPower: 110-240V, 50/60Hz.\nCompatible with standard dental operatory electrical infrastructure.\nNetwork connectivity via Ethernet\nRadiographic Unit, Dental, Wall Mounted, 7mA\nThe system shall be a wall-mounted intraoral dental X-ray unit with extended reach (long arm configuration) for use in general dentistry, oral surgery, and specialty dental clinics. \nImaging Performance\nHigh-frequency DC X-ray generator.\nConstant potential output for consistent image quality.\nTube voltage approximately 60-70 kVp.\nTube current approximately 7 mA (or equivalent).\nExposure time range suitable for digital sensors and phosphor plates.\nCompatible with:\nDigital intraoral sensors\nTraditional film\nRectangular collimation capability (preferred) to reduce patient dose.\nFocal spot size approximately 0.7 mm or smaller.\nLong Arm Configuration\nExtended arm reach minimum 81 inches (or equivalent).\nDouble-articulating arm for flexible positioning.\nSmooth, drift-free positioning.\nStable tube head that maintains selected position without sag.\nWall-mounted installation with appropriate structural support requirements provided.\nLong arm shall accommodate large operatories and specialty treatment rooms.\nControl & Interface\nWall-mounted control panel.\nProgrammable exposure presets for:\nAdult anterior/posterior\nPediatric anterior/posterior\nDigital display for exposure time.\nManual exposure adjustment capability.\nError codes or diagnostic display.\nSafety & Radiation Protection\nCompliance with FDA and NCRP radiation standards.\nMinimum total filtration equivalent to 2.5 mm aluminum at 70 kVp.\nDead-man type exposure switch.\nMinimum source-to-skin distance compliant with federal standards.\nAudible and visual exposure indicators.\nLeakage radiation within regulatory limits.\nMechanical & Ergonomic Features\nLightweight tube head.\n360-degree rotational capability at arm and tube head joints.\nSmooth, low-resistance movement.\nSealed, oil-cooled X-ray tube housing.\nEasy-to-clean surfaces suitable for clinical infection control.\nElectrical Requirements\nStandard 110-120V electrical service.\nCompatible with standard dental operatory electrical infrastructure.\nLine voltage regulation to ensure stable output.\nSensor Kit, Dental Imaging System, Size 1 & Size 2 \nThe system shall consist of direct digital intraoral radiography sensors, Size 1 and Size 2, compatible with standard intraoral dental X-ray generators. Sensors shall be new, current production models designed for high-resolution diagnostic imaging in general dentistry and specialty dental clinics.\nSensor Technology\nCMOS or equivalent digital sensor technology.\nTrue resolution minimum 20 line pairs/mm (or equivalent high-resolution performance).\nTheoretical resolution up to 24 lp/mm (or equivalent).\nPixel size approximately 19-20 Âµm (or better).\nActive imaging area optimized for diagnostic accuracy.\nMust include:\nSize 1 (Pediatric/Anterior)\nActive area approximately 20 x 30 mm (or equivalent).\nSlim profile for patient comfort.\nRounded corners for intraoral comfort.\nSize 2 (Adult/Posterior Standard)\nActive area approximately 26 x 36 mm (or equivalent).\nStandard adult posterior imaging size.\nErgonomic shape for ease of positioning.\nImage Quality & Performance\nHigh contrast resolution suitable for:\nCaries detection\nEndodontic evaluation\nPeriapical imaging\nPeriodontal assessment\nWide dynamic range.\nNoise reduction capability.\nAutomatic exposure detection.\nCompatible with standard 60-70 kVp intraoral X-ray units.\nDurability & Construction\nShock-resistant housing.\nReinforced cable attachment.\nCable length minimum 2 meters (or equivalent).\nWater-resistant and disinfectant-resistant outer casing.\nIP rating suitable for clinical dental environments.\nSensor thickness designed to enhance patient comfort.\nSoftware & Integration\nManufacturer-provided imaging software included or compatible.\nTWAIN and DICOM compliant.\nCompatible with:\nPACS systems\nDental imaging software platforms\nPractice management systems\nUSB connectivity.\nPlug-and-play configuration.\nInfection Control\nCompatible with standard disposable sensor barriers.\nSmooth, sealed housing for disinfection.\nManufacturer-recommended cleaning protocols provided.\nElectrical & Technical Requirements\nUSB 2.0 or higher connectivity.\nCompatible with Windows-based acquisition workstations.\n\nThe information identified above are intended to be descriptive, not restrictive, and to indicate the quality of the supplies that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications.\n\nIf you are interested and are capable of providing the sought-out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: \n\nPlease indicate the size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)?\n\n\nIs your company considered small under the NAICS code identified under this RFI?\n\n\n\nAre you the manufacturer, an authorized distributor, or an equivalent solution to the items being referenced above? If an authorized distributor must provide proof.\n\n\n\nIf you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, are you providing the equipment from a small business manufacturer?\n\n\nDo you alter, assemble, or modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\n\n\n\nDoes your company have an FSS contract with GSA, VA NAC, NASA SEWP, or any other federal contract, that can be utilized to procure the requirement listed above? If so, please provide the contract number.\n\n\n\nWhere is the product manufactured?\n\n\nPlease submit your capabilities that show clear, compelling, and convincing evidence that you can meet the requirement described in the attached SOW. \n\n\n\nPlease provide your UEI number.\n\n\nResponses to this notice shall be submitted via email to Tracie Raggs at tracie.raggs@va.gov. Telephone responses shall not be accepted. Responses must be received no later than Friday, July 10, 2026, at 0800 CST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this sources sought. Responses to this sources sought notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation","origin":"detail"},"contacts":[{"name":"Tracie Raggs","role":"primary","email":"tracie.raggs@va.gov","phone":"913-946-1985","title":"Contract Specialist"}],"place_of_performance":{"zip":"65401","city":{"name":"Rolla"},"state":{"name":"MO"},"street":"Rolla Community Based Outpatient Clinic (CBOC)","country":{"code":"USA","name":"UNITED STATES"},"street2":"13063 Old Wire Rd"},"office_address":{"zip":"66048","city":"LEAVENWORTH","state":"KS","country":"USA"},"naics_codes":["339114"],"award":{"awardee":{}},"attachments":[{"resource_id":"c986e8f313e14090b5eab7b5e1efe75e","name":"36C25526Q0487.docx","kind":"file","mime_type":".docx","size_bytes":31414,"posted_at":"2026-06-30T20:04:39.508Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/c986e8f313e14090b5eab7b5e1efe75e/download","mirrored":false}],"awards":[],"related":[{"key":"36C25527R0016","latest_notice_id":"a7eee67b427c47158525b1a79fc8ecd2","title":"Z2DA--657-24-102JC - Prepare Site for New PET/CT, Room A011D (MD) FY27 NRM VISN Base, CON (VA-27-00017492) 657-27-1-8434-0001","solicitation_number":"36C25527R0016","notice_type":"p","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"236220","psc":"Z2DA","set_aside":"SDVOSBC","state":"MO","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"WORK: THE GENERAL DESCRIPTION: VA SAINT LOUIS HEALTH CARE SYSTEM","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C25526Q0617","latest_notice_id":"3506983a2af048deaf442eae0f8b8a04","title":"H112--Annual/Sem-i annual fire smoke inspections and auto door services l EKH","solicitation_number":"36C25526Q0617","notice_type":"o","first_type":"r","first_posted":"2026-08-19","last_posted":"2026-11-18","notices":11,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"541350","psc":"H112","set_aside":"SBA","state":"KS","county":"20103","county_name":"Leavenworth County","city":"2039000","city_name":"Leavenworth","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C25527Q0057","latest_notice_id":"fbd76a4c366d45e896674756383b4fb2","title":"C222--589-27-108, Correct Electrical Deficiencies in Building 26 KCVA (ME) FY27 NRM VISN Base - AE (VA-27-00021035)","solicitation_number":"36C25527Q0057","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":2,"due_at":"2026-12-01T20:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"541330","psc":"C222","set_aside":"EDWOSB","state":"MO","county":"29095","county_name":"Jackson County","city":"2938000","city_name":"Kansas City","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T09:15:14.204648Z"},{"key":"36C25527Q00571","latest_notice_id":"53c5d2376d9e4fb79d39a712a62deb10","title":"C222--589-27-108, Correct Electrical Deficiencies in Building 26 KCVA (ME) FY27 NRM VISN Base - AE (VA-27-00021035)","solicitation_number":"36C25527Q0057_1","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-12-01T20:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"541330","psc":"C222","set_aside":"SDVOSBC","state":"MO","county":"29095","county_name":"Jackson County","city":"2938000","city_name":"Kansas City","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C25527Q0053","latest_notice_id":"f87b14f3ce2643d69bdc633c0b05a712","title":"J065--Imaging Service & Maintenance EHCC & MTV","solicitation_number":"36C25527Q0053","notice_type":"o","first_type":"p","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":2,"due_at":"2026-12-02T14:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"811210","psc":"J065","set_aside":null,"state":"IN","county":"18163","county_name":"Vanderburgh County","city":"1822000","city_name":"Evansville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open":[],"similar_open_total":0,"indexable":false}