Solicitation, service-disabled veteran-owned small business set-aside
AMSCO Pass Through Dry Cabinet
36C25526Q0323
Department of Veterans Affairs, 255-Network Contract Office 15. Electromedical and Electrotherapeutic Apparatus Manufacturing.
Awarded
$121,364.18 obligated so far on USAspending
Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities
This one was awarded in 2026
11 like it are open now in electromedical and electrotherapeutic apparatus manufacturing
- NCSS - Sentec tCOM+ Transcutaneous CO2 Monitor Acq
National Institutes of Health, National Institutes of Health Olao
Combined synopsis and solicitationNAICS 334510Ship to the buyer75N98027Q00094Due tomorrowNov 27 - Medtronic FT10 Series Cauterizer
Department of Veterans Affairs, Network Contract Office 23
Combined synopsis and solicitationSDVOSBNAICS 334510Ship to Fargo, ND36C26327Q0131Due in 4 daysNov 30 - FY27 Mobile CT Scanner Lease
Department of Veterans Affairs, 248-Network Contract Office 8
Combined synopsis and solicitationNAICS 334510Orlando, FL36C24827Q0085Due in 4 daysNov 30
All 11 open in electromedical and electrotherapeutic apparatus manufacturing
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Solicitation. A formal request for proposals, quotes or bids. Offers are due by the response deadline. Glossary
- Who may compete
- Service-disabled veteran-owned small business set-aside. Reserved for service-disabled veteran-owned small businesses. Small, under NAICS 334510 (electromedical and electrotherapeutic apparatus manufacturing), means no more than 1,250 employees, counted with affiliates. Open SDVOSB opportunities
- Time to respond
- Bidders had 12 days from the day the solicitation was posted, April 16, 2026, to the deadline.
- How it ended
- Awarded to Beacon Point Associates LLC on May 5, 2026, 7 days after offers were due. The contracting office reported 2 offers (competed under simplified acquisition procedures).
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
1. STATEMENT OF WORK
The contractor shall provide all services, labor, travel, transportation, material, shipping, parts,
connections, and equipment necessary for provision and on-site installation of equipment to
provide a minimum quantity of two pass-through instrument drying cabinet units located at 4801 Linwood Blvd, Kansas City MO 64128. The pass-through instrument drying cabinets are needed to support Sterile Processing Service (SPS) for reprocessing reusable medical devices (RMD) used in invasive procedures. They are needed to support medical procedures and surgeries in the operating room, dental clinic, and surgical clinic.
The contractor shall also provide training to clinical staff prior to equipment use, capturing all tours of duty for the sterile processing department. The contractor is responsible for removing and disposing of all debris and packing material left from the installation of the pass-through instrument drying cabinets.
The contract includes two pass-through instrument drying cabinets, and full installation services to include necessary installation components to support wall structure for pass-through capabilities per schedule below:
2. SPECIFICATIONS
- Minimum of two (2) pass-through instrument drying cabinets shall have maximum individual dimensions of 78 inches (H) x 38 inches (W) x 31 inches (D), for a total space occupancy of 80 inches (H) x 76 inches (W) x 32 inches (D).
- The pass-through instrument drying cabinets shall maintain full separation between the decontamination environment and high level disinfection environment with no risk of cross contamination between the areas (AAMI ST91-21).
- The facility space in which the AER can occupy is approximately 8.2’ (L) x 8.8’ (h)
- Ability to support drying of canulated instrumentation’s internal channels.
- Ability to support drying of internal channels of DaVinci robotic arms.
- Built in HEPA filtrated air with HEPA air purge connectors for lumens.
- Ability to dry heat-sensitive devices.
- Ability to maintain temperature between 63°F - 77°F (17°C - 25°C) and humidity between 30%-60% RH
- Instrument drying cabinet must support utility requirements:
- 120Vac, 60Hz, 20 Amp, 53dBa
- Maximum weight per cabinet of 750 lb (340kg)
3. REQUIREMENTS
- It is the responsibility of the Contractor to conduct site visits, verify existing conditions, quantities of materials, installation instruction of materials to be used, and discrepancies or conflicting requirements in the Statement of Work before preparing the Final Proposal.
- The contractor shall provide and install two pass-through instrument drying cabinets to the VA Medical Center located at 4801 Linwood Kansas City, Mo 64128.
- The contractor shall ensure that all repairs, preventable, and remedial maintenance provided during the provision timeframe of this contract meet and or exceed the OEM’s specifications.
- The contractor shall ensure that only FULLY QUALIFIED TECHNICIANS/ENGINEERS are employed in the performance of all work performed under this contract.
- The contractor shall ensure that the highest standard of professional capability and workmanship is maintained throughout the life of this contract.
4. EQUIPMENT MAINTENANCE & RESPONSE TIMES
The vendor shall provide full-service maintenance through a service agreement for minimum 2 years post installation. The vendor shall provide all additional recurring and preventive maintenance activities:
- Emergency response for equipment and MSPS failures. The vendor shall respond to the facility for any equipment failure resulting in a total or partial loss of the equipment installed within or any portion of the mobile sterile processing system within 4 hours from the time of VAMC contact. If a permanent solution cannot be resolved within 24 hours of initial failure, a temporary solution shall be operational within 24 hours of initial failure. An agreed permanent solution shall be planned, and replacements ordered within 5 business days of initial failure.
5. SAFETY
The contractor/vendor shall always, ensure that all work provided complies with all local, State, and Federal rules and regulations pertaining to workplace safety. The contractor shall take all proper safety and health precautions to protect the work, the workers, the public and the property (OSHA). Installs and construction work will be in accordance with all applicable codes to include the most current codes National Fire Protection Association (NFPA), and the VA Design Guide Manuals that are applicable to the work. If the design guide is equivalent or more stringent then the mentioned codes, the VA Design Guide takes precedence.
6. DOCUMENTATION
The contractor shall furnish to the KCVA Medical Center Biomedical Engineering department legible hard copies and electronic copies of service reports of the maintenance indicating details of the maintenance performed upon completion of all work.
7. PLACE OF PERFORMANCE
Kansas City Veteran Administration Medical Center, 4801 Linwood Blvd. Kansas City 64128
8. PERFORMANCE MONITORING
The contractor’s performance will be monitored by the Contracting Officer (CO), Contracting Officer Representative (COR), Infection Control Risk Assessment Office, and Safety Office during the rental agreement period.
Coordinate all administrative and construction requirements exclusively with or through assigned Contracting Officer Representative (COR).
The Construction Safety Officer, Construction Safety Committee, and COR will review the operations and site construction conditions of the project to confirm that all Safety regulations relating to construction and healthcare facilities are being adhered to. Daily and weekly safety rounds will be conducted. For non-compliance safety related issues, a safety report will be sent to the Contractor to correct within 14 days. Non-compliance may result in job-site suspense until compliance is met at the contractor’s expense.
9. HOURS OF OPERATION
The contractor will perform services required during the hours of 7:30 am – 4:00 pm, Monday through Friday or as directed by the designated COR.
10. SECURITY/ IDENTIFICATION
“The C&A requirements do not apply, and Security Accreditation Package is not required” Taking of photographs/videos/recording of any kind is PROHIBITED on VA premises unless pertaining to work assignment, instructed or authorized by the Contracting Officer’s Representative (COR).
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- 36C25526Q0323.pdf425 KB, April 16, 2026
The contract, on USAspending
Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.
- Recipient
- Beacon Point Associates LLC
- UEI
- L97MMG5VW9N7
- CAGE
- 6U5B7
- Vendor location
- Cape Coral, FL
- Contract
- 36C25526P0180, purchase order
- Obligated
- $121,364.18
- Actions
- 2 between May 5, 2026 and October 8, 2026
- Competition
- Competed Under SAP, 2 offers received
- Set-aside reported
- Service Disabled Veteran Owned Small Business SET-ASIDE
- Described as
- Amsco Pass Through Dry Cabinet
- Match
- solicitation number 36C25526Q0323 equals the FPDS solicitation identifier; same awarding office 36C255 (high confidence)
- Record
- USAspending award page
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
April 16, 2026
Solicitation, originally sources sought
Due April 28, 2026 at 12:00 PM EDT. SAM.gov, notice 45136410c38644f6b725679810f96c3d
2 revisions on SAM
- April 16, 2026: publish, solicitation
- April 3, 2026: publish, sources sought
Points of contact