Skip to content

SealedBidder is a private company, not a government agency.

Sign upDashboard
  • 8,708 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell SealedBidder what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and SealedBidder tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $99 a month. See your matches before you pay.
See plans

Sources sought

PORTABLE ECMO HEART-LUNG MACHINE

36C25525Q0519

Department of Veterans Affairs, 255-Network Contract Office 15. Electromedical and Electrotherapeutic Apparatus Manufacturing.

Response deadline

August 6, 2025 at 12:00 PM EDT

Closed 477 days ago. Posted July 30, 2025. Scheduled to archive August 16, 2025.

Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities

This one closed in 2025

11 like it are open now in electromedical and electrotherapeutic apparatus manufacturing

  • NCSS - Sentec tCOM+ Transcutaneous CO2 Monitor Acq

    National Institutes of Health, National Institutes of Health Olao

    Combined synopsis and solicitationNAICS 334510Ship to the buyer75N98027Q00094
    Due tomorrowNov 27
  • Medtronic FT10 Series Cauterizer

    Department of Veterans Affairs, Network Contract Office 23

    Combined synopsis and solicitationSDVOSBNAICS 334510Ship to Fargo, ND36C26327Q0131
    Due in 4 daysNov 30
  • FY27 Mobile CT Scanner Lease

    Department of Veterans Affairs, 248-Network Contract Office 8

    Combined synopsis and solicitationNAICS 334510Orlando, FL36C24827Q0085
    Due in 4 daysNov 30

All 11 open in electromedical and electrotherapeutic apparatus manufacturing

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
Who may compete
SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 334510 (electromedical and electrotherapeutic apparatus manufacturing), means no more than 1,250 employees, counted with affiliates. What a set-aside is
What comes next
No solicitation was published under this number after the sources sought of July 30, 2025. An agency sometimes issues the solicitation under a new number.

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov.

This is a SOURCES SOUGHT announcement only. It is neither a solicitation announcement nor a request for proposal or quote and does not obligate the Government to award a contract. Responses to this Sources Sought must be in writing. The purpose of this Sources Sought Announcement is for market research, to make appropriate acquisition decisions, and to gain knowledge of potential qualified businesses capable of providing the following: Portable Heart Lung Machine for Columbia VAMC *** See Statement of Requirement below for details *** If this is within your capability, please respond with the information below: Company Name Address Point of Contact Phone, Fax, and Email UEI number GSA Contract (as applicable) Capability Statement that clearly and convincingly identifies your ability to fulfill this requirement. Brochures of products being offered to include specifications. Meet the Buy American statute FAR 52.225-1, where the product is manufactured. Authorized service provider letter from OEM Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications to be considered for award. In addition, FAR 4.11 states that prospective contractors shall be registered in the System for Award Management (www.SAM.gov) database. All Service-Disabled Veteran Owned Small Businesses (SDVOSB) and Veteran Owned Small Businesses (VOSB) shall be verified in VetCert at https://veterans.certify.sba.gov Point of Contact for this Sources Sought is: veronica.flores@va.gov Department of Veterans Affairs Network Contracting Office -15 3450 S. 4th Street Trafficway Leavenworth, KS. 66048  STATEMENT OF REQUIREMENTS GENERAL INFORMATION 1.0 Scope of Work: Harry S Truman VA Hospital (HSTVA) needs new life saving equipment. This equipment is a heart bypass machine. HSTVA current Maquet Cardiohelp lung support systems are more than 10 years old and need to be replaced. HSTVA is requiring two new portable cardio lung supports systems to replace the Cardiohelp Maquet system. The component of the cardio lung supports systems need to include a pump, oxygenator, heat exchanger, cannulas, and tubing. 2.0 Background: The current system in place is a Cardiohelp Maquet System and the need for a new system to replace it is greatly needed. The new system MUST be FDA approved and not have any current recalls. CONTRACTOR REQUIREMENTS 3.0 Technical Requirements/Tasks: The system must be able to do the following: An ECMO machine primarily consists of a mechanical blood pump, a membrane oxygenator (artificial lung), a heat exchanger to regulate blood temperature, and tubing connecting to cannulas (large tubes) that are inserted into the patient's veins and arteries, allowing the machine to draw blood out, oxygenate it, remove carbon dioxide, and then return it to the body; essentially acting as a temporary replacement for the heart and lungs when they cannot function adequately. The ECMO machine must include: Pump: This component forcefully pushes the patient's blood through the circuit. Oxygenator (membrane lung): This is where gas exchange occurs, adding oxygen and removing carbon dioxide from the blood. Heat exchanger: Ensures the blood is warmed to the patient's body temperature before being returned. Cannulas: Large tubes inserted into the patient's blood vessels, one to draw blood out and another to return oxygenated blood. Tubing: Connects the cannulas to the pump and oxygenator, allowing blood to flow through the circuit. 4.0 Salient Characteristics: The Cart must be compact and able to fit through any doorway. Cart must be able to fit into an OR room or normal patient room on the floor such as ICU. (Intensive Care Unit). It must be easily portable to move and transport patients from hospital to any ambulatory transportation. Battery Life must be least 90 mins when fully charged. The unit must include an LED speed indicator integrated into the top of the console to display the speed independently of the touchscreen. The console must have a weight bearing carrying handle on top of the console that includes an integrated holder that must accept the emergency hand crank. The console must have a safety bar to protect the console and the attached disposable. The console must have a pump drive capable of accepting the centrifugal pump of the HLS Set 7.0 or 5.0 disposable circuit The console must have a combined flow/bubble sensor for flow measurement and arterial bubble monitoring. The console must have the capability and expandability to add a bubble sensor for venous bubble monitoring if desired. The console must have a venous probe to measure the venous blood parameters of SV O2, Hb, Hct and temperature. This probe must be able to attach to the Venous Cell of the HLS Set 7.0 or 5.0 disposable circuit. The console must have an emergency hand crank used in emergency situations to manually drive the HLS Set 7.0 or 5.0 disposable circuit. The console must have an emergency mode button that can be activated in the event of failure of the touchscreen or other components to operate the disposable and control its speed directly via the rotary knob. The console must have a Zero Flow mode during which the system must aim at a flow of 0 l/min by controlling the pump accordingly. In this way, both forward and backward flow can be prevented The console must have backflow prevention to detect and respond to a backflow of blood. The console must monitor the blood flow, display any alarms and activate the zero-flow mode automatically to prevent any backflow. The console must have bubble detection to monitor for arterial bubbles. It must have the ability to trigger an intervention and/or an alarm when bubbles are detected. With a user activated intervention, the detection of bubbles by the flow/ bubble sensor must trigger a pump stop. The console must have the ability to provide Offline Recording to record data in an internal memory and later exported to a USB drive if desired by the user. The console must have a rotary knob to enable the clinician to change the setpoint speed or the setpoint flow The console s user interface must be a touch screen and could display: Flow and LPM Pressure Internal, Pressure Arterial, Pressure Venous and Dela P Arterial Temperature and Venous Temperature SVO2, HB, HCT Visual Alarms System Lock status Battery Status The console s user interface must also include a separate Keypad next to the touch screen with: Lock/Unlock LED & button On/Off LED & button Zero Flow Mode LED & button Safety LED button Battery status LED The clinician must have the ability to set both alarms and interventions for: LPM or RPM Pressure Venous, Pressure Arterial and Pressure Internal. Arterial bubble sensor Venous bubble sensor 5.0 Deliverables / Schedule: Deliverables of this system must be shipped to 800 Hospital Dr Columbia MO 65201. ATT: Warehouse foreman, All equipment and components must be shipped together. All equipment and components must be tracked upon shipment and tracking number given to the POC. Federal Holidays Observed by the VA Medical Center New Year's Day Labor Day  Martin Luther King, Jr. Day Columbus Day  President's Day  Veterans Day  Memorial Day  Thanksgiving Day  Juneteenth  Christmas Day  Independence Day    and any other day specifically designated by the President of the United States.  6.0 Training: Travel for training and install must be done by vendor after the delivery receipt of the equipment. No additional fees must be incurred outside the quote. Any fees must be identified in the quote of the procurement not noted later. The vendor must handle all traveling to meet the needs of installation and training. Vendor must provide training and installation of equipment with local Biomedical rep from HSTVA to ensure equipment is working properly. 7.0 Data Rights: All rights and admin privileges must be handed over to HSTVA upon install of equipment.

Attachments

Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. July 30, 2025

    Sources sought

    Due August 6, 2025 at 12:00 PM EDT. SAM.gov, notice 93a59a4dde8e4bd5bca78fedb33f1bda

    1 revision on SAM
    • July 30, 2025: publish, sources sought

Points of contact