{"canonical":"https://sealedbidder.com/opportunities/36c25525q0328","key":"36C25525Q0328","url":"https://sealedbidder.com/opportunities/36c25525q0328","title":"Thyroid Uptake System, Poplar Bluff, MO VAMC","solicitation_number":"36C25525Q0328","notice_type":"o","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-05-16T16:00:00Z","first_posted":"2025-05-09","last_posted":"2025-05-09","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"334510","psc":"6515","set_aside":"SDVOSBC","place_state":"MO","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"29023","place_county_name":"Butler County","place_city":"2959096","place_city_name":"Poplar Bluff","winner":"DGA MEDICAL LLC","award_amount":null,"publications":[{"notice_id":"c8aed55f45714c4ea51fe0d57b35e8cd","title":"Thyroid Uptake System, Poplar Bluff, MO VAMC","solicitation_number":"36C25525Q0328","notice_type":"o","base_type":"r","posted":"2025-05-09","posted_at":"2025-05-09T13:34:00.579Z","due_at":"2025-05-16T16:00:00Z","due_date":"2025-05-16","cancelled":false,"archived":true,"archive_date":"2025-05-31","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/c8aed55f45714c4ea51fe0d57b35e8cd/view","enriched":true,"history":[{"index":6,"title":"Thyroid Uptake System, Poplar Bluff, MO VAMC","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-05-09T13:34:00.579Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"c8aed55f45714c4ea51fe0d57b35e8cd","solicitation_number":"36C25525Q0328","related_opportunity_id":"bb71221c18964a2dbd4c9e8ac64d7c50"},{"index":3,"title":"Thyroid Uptake System, Poplar Bluff, MO VAMC","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-14T16:21:20.683Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"bb71221c18964a2dbd4c9e8ac64d7c50","solicitation_number":"36C25525Q0265"}]}],"latest_notice_id":"c8aed55f45714c4ea51fe0d57b35e8cd","first_type":"o","notices":[{"dates":{"posted":"2025-05-09","posted_at":"2025-05-09T13:34:00.579Z","created_at":"2025-05-09T13:30:06.605Z","modified_at":"2025-06-01T03:55:49.720Z","response_deadline":{"raw":"2025-05-16T11:00:00-05:00","utc":"2025-05-16T16:00:00Z","date":"2025-05-16","time":"11:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/c8aed55f45714c4ea51fe0d57b35e8cd/view"},"naics":{"codes":["334510"],"primary":"334510"},"title":"Thyroid Uptake System, Poplar Bluff, MO VAMC","agency":{"office":{"code":"36C255","name":"255-NETWORK CONTRACT OFFICE 15 (36C255)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"66048","city":"LEAVENWORTH","state":"KS","country":"USA"},"organization_id":"100186523","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-05-31","archive_type":"auto15"},"history":[{"index":6,"title":"Thyroid Uptake System, Poplar Bluff, MO VAMC","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-05-09T13:34:00.579Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"c8aed55f45714c4ea51fe0d57b35e8cd","solicitation_number":"36C25525Q0328","related_opportunity_id":"bb71221c18964a2dbd4c9e8ac64d7c50"},{"index":3,"title":"Thyroid Uptake System, Poplar Bluff, MO VAMC","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-14T16:21:20.683Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"bb71221c18964a2dbd4c9e8ac64d7c50","solicitation_number":"36C25525Q0265"}],"contacts":[{"name":"Tywanna Sparks","role":"primary","email":"tywanna.sparks@va.gov","phone":"9137589928"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"c8aed55f45714c4ea51fe0d57b35e8cd","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"bb71221c18964a2dbd4c9e8ac64d7c50","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-15T09:13:57.213899328Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"3ee204ce8f0fe1d0142da931e8380646740ce5fc4ce146b0b065542d65c09293","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-15T09:13:57.213899328Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>STATEMENT OF REQUIREMENT<br />\nA. GENERAL INFORMATION<br />\nThe Nuclear Medicine service at John J. Pershing VA Medical Center (VAMC) in Poplar Bluff, MO will better serve its Veterans by acquiring this Thyroid Uptake System with Well Counting System with 2 Inch Well Shielding, a multi-purpose spectrum analysis instrument designed for diverse nuclear medicine applications. The system performs Uptake studies, wipe tests, and other user-defined tasks that are accomplished with speed and precision using this fully integrated computer-controlled instrument and its comprehensive selection of application software.<br />\nEngineered for mobility, durability and operational efficiency, the unit handles clinical tests, safety compliance tasks, and system administration procedures quickly and accurately. Built-in menus follow conventionally established nuclear medicine procedures, providing step-by-step guidance throughout defined procedures. The system automatically performs calculations, stores patient information and test results, and outputs clear, concise reports. User-defined uptake protocols can be initiated.<br />\nB. SCOPE<br />\nDelivery of the Thyroid Uptake system will allow a bioassay program for quick and efficient measurement of the staff thyroid burden for radiopharmaceuticals, I-123, I-125 and I-131. Measurement results can be reported in cpm, dpm, uCi, or Bq. Action levels may be set by the user for each isotope. System reporting facilitates single bioassay report, summary of multiple bioassays on an individual staff member, and summary report on multiple staff members. Reports are easily printed or saved as PDF files<br />\nThe Thyroid Uptake program supports multiple time-stamped uptake measurements, auto decay correction, user-defined uptake protocols, on-screen spectrum acquisition and analysis. The system provides reports that include normal ranges and allow notes/comments entered by the facility physician and technologists.<br />\nThe wipe test application automatically calculates net contamination levels and reports results in dpm, uCi and Bq. The program allows compliance with regulations for counting and reporting results of wipes taken for contamination surveys. The system allows user to define an unlimited number of &ldquo;Area&rdquo; names and wipe &ldquo;Locations&rdquo; entered within the areas for testing and documentation. Each area may be designated as &ldquo;restricted&rdquo;, &ldquo;unrestricted&rdquo;, &ldquo;package&rdquo; or &ldquo;sealed source&rdquo;. The user may specify count times, activity units, wide window, and individual isotopes and geometric efficiencies or simply utilize the wide range of factory default options.<br />\nThe program displays and stores the full spectrum with each wipe, automatically calculates net contamination levels and reports results in dpm, uCi or Bq. Wipes above the user defined trigger levels are easily identified. A detailed spectrum analysis may<br />\nalso be performed for any wipe to help identify isotopes causing contamination. Customized reports can be printed or saved in PDF format.<br />\nThe application specialist will provide training and guidance to ensure safe use of the equipment and the study and administration applications provided. The contractor will provide cybersecurity best practices information and training, when applicable.<br />\nThe contractor will provide application update to ensure information security in the current equipment and other factors that interconnects with the imaging system including the network, other current peripheral applications and other new tools and software that will be developed or installed to work with the current work station and imaging equipment hardware and software.<br />\nC. REQUIREMENT/SALIENT CHARACTERISTICS/SPECIFICATIONS<br />\nCommon Nomenclature: Medical Spectrometer Hardware<br />\nKind of material: ALL IN ONE Touch Screen Computer<br />\nElectrical Data:<br />\nPower: Low voltage transformer with hospital grade power cord and plug.<br />\nLine Voltage: 120 VAC, 60 Hz, 2 AMP circuit breaker; 230 VAC, 50 Hz, 1 AMP circuit breaker<br />\nDimensions, size, capacity:<br />\nMinimum articulating arm with a minimum of 34-inch vertical range of travel with a minimum of 220-degree collimator rotation.<br />\nPrinciples of operation:<br />\nMulti-Channel Analyzer:<br />\nChannels: 1024<br />\nSpectral Resolution: FWHM 8%<br />\nCount Rate: (Maximum) 150,000 cps for Tc-99m<br />\nCount Rate Stability: 99%<br />\nGross Count Rate Linearity: Within 5% up to 150,000 cps<br />\nPulse Height Linearity: Within 2% (independent of detector)<br />\nDetector High Voltage Adjustment: Automatic adjustment for both probe and well; uses 10 &mu;Ci Cs-137 as the calibration source.<br />\nRestrictive environmental conditions: User Set: Unlimited user defined Isotopes, setting ROI, half-life, name, efficiency and range.<br />\nIntended use:<br />\nFactory Programmed: Au-198, Ba-133, Co-57, Co-58, Co-60, Cr-51, Cs-137, F-18, Fe-59, Ga-67, Ga-68, Gd-153, Ge-68/Ga-68, Hg-197, I-123, I-125, I-131, In-111, Ir-192, K-42, Lu-177, Na-22, Na-24, Pd-103, Ra-223, Se-75, Sr-85, Tc-99m, Tc-99m/Tl-201, Tl-201, Yb-169, Wide Window.<br />\nEquipment with which the item is used, Job related tools:<br />\nProbe: 2&quot; x 2&quot; Nal (Tl) integral line scintillation detector<br />\nOther pertinent information that describes the item, material or service required:<br />\nUptake Stand:<br />\nDimensions:<br />\nArm down and retracted: 34&quot; l x 26&quot; w x 55&quot; h (86.4 x 66 x 139.7 cm)<br />\nMaximum Height: 60&quot; (152.4 cm)<br />\nMaximum Length: Arm Extended: 61&quot; (154.9 cm)<br />\nCollimated Shield: Flat field collimator meeting IAEA specifications<br />\nPositioning: Distance bar and positioning light<br />\nCasters: 4&quot; Total locking<br />\nMaximum weigh of 300 lbs.<br />\nA maximum combined weight with Well Counter: 350 lbs.<br />\nPower: Low voltage transformer with hospital grade power cord and plug.<br />\nLine Voltage: 120 VAC, 60 Hz, 2 AMP circuit breaker; 230 VAC, 50 Hz, 1 AMP circuit breaker<br />\nOTHER UNIQUE REQUIREMENTS: Minimum of two-inch well container<br />\nCompatibility with Existing Equipment: TRM Compliance with VA Directives<br />\nWINDOWS 10 compatible or Newest Windows Version compliance with VHA standards.<br />\nMust be DICOM compliance, Directives or IT Policies, Required.<br />\nCoordination with On-going Construction Project (provide the project number): N/A<br />\nWarranty: 1 year from date of receipt and verification of installation/operation. Two years part/labor warranty<br />\nTraining: Initial installation and launch training staff and service support<br />\nService and/or Maintenance: Preventive maintenance and training support, to include two Operating Manuals and two Service Manuals<br />\nSafety/ISO/IT/BioMed/SPS &amp; Other Departmental Compliance: Must meet Technical Reference Model (TRM) VA/BioMed Compliance.<br />\nD. DELIVERY<br />\nContractor must deliver all components of the system within 30 days of award notice.<br />\nStandard FOB Destination to:<br />\nJohn J. Pershing VA Medical Center<br />\n1500 North Westwood Blvd<br />\nPoplar Bluff MO 63901<br />\nGovernment-Furnished Property, Material, Equipment, or Information (GFP, GFM, GFE, or GFI) N/A<br />\nSECURITY N/A<br />\nSPECIAL MATERIAL REQUIREMENT: Two Operator&rsquo;s Manuals and two Service Manuals<br />\nE. PLACE OF PERFORMANCE<br />\nThe system will be installed, serviced, and updated at the facility, John J. Pershing VAMC, Poplar Bluff, MO, Nuclear Medicine Department. Servicing, training, and support of personnel will be per stipulations on the final contract.</p>","text":"STATEMENT OF REQUIREMENT\n\nA. GENERAL INFORMATION\n\nThe Nuclear Medicine service at John J. Pershing VA Medical Center (VAMC) in Poplar Bluff, MO will better serve its Veterans by acquiring this Thyroid Uptake System with Well Counting System with 2 Inch Well Shielding, a multi-purpose spectrum analysis instrument designed for diverse nuclear medicine applications. The system performs Uptake studies, wipe tests, and other user-defined tasks that are accomplished with speed and precision using this fully integrated computer-controlled instrument and its comprehensive selection of application software.\n\nEngineered for mobility, durability and operational efficiency, the unit handles clinical tests, safety compliance tasks, and system administration procedures quickly and accurately. Built-in menus follow conventionally established nuclear medicine procedures, providing step-by-step guidance throughout defined procedures. The system automatically performs calculations, stores patient information and test results, and outputs clear, concise reports. User-defined uptake protocols can be initiated.\n\nB. SCOPE\n\nDelivery of the Thyroid Uptake system will allow a bioassay program for quick and efficient measurement of the staff thyroid burden for radiopharmaceuticals, I-123, I-125 and I-131. Measurement results can be reported in cpm, dpm, uCi, or Bq. Action levels may be set by the user for each isotope. System reporting facilitates single bioassay report, summary of multiple bioassays on an individual staff member, and summary report on multiple staff members. Reports are easily printed or saved as PDF files\n\nThe Thyroid Uptake program supports multiple time-stamped uptake measurements, auto decay correction, user-defined uptake protocols, on-screen spectrum acquisition and analysis. The system provides reports that include normal ranges and allow notes/comments entered by the facility physician and technologists.\n\nThe wipe test application automatically calculates net contamination levels and reports results in dpm, uCi and Bq. The program allows compliance with regulations for counting and reporting results of wipes taken for contamination surveys. The system allows user to define an unlimited number of “Area” names and wipe “Locations” entered within the areas for testing and documentation. Each area may be designated as “restricted”, “unrestricted”, “package” or “sealed source”. The user may specify count times, activity units, wide window, and individual isotopes and geometric efficiencies or simply utilize the wide range of factory default options.\n\nThe program displays and stores the full spectrum with each wipe, automatically calculates net contamination levels and reports results in dpm, uCi or Bq. Wipes above the user defined trigger levels are easily identified. A detailed spectrum analysis may\n\nalso be performed for any wipe to help identify isotopes causing contamination. Customized reports can be printed or saved in PDF format.\n\nThe application specialist will provide training and guidance to ensure safe use of the equipment and the study and administration applications provided. The contractor will provide cybersecurity best practices information and training, when applicable.\n\nThe contractor will provide application update to ensure information security in the current equipment and other factors that interconnects with the imaging system including the network, other current peripheral applications and other new tools and software that will be developed or installed to work with the current work station and imaging equipment hardware and software.\n\nC. REQUIREMENT/SALIENT CHARACTERISTICS/SPECIFICATIONS\n\nCommon Nomenclature: Medical Spectrometer Hardware\n\nKind of material: ALL IN ONE Touch Screen Computer\n\nElectrical Data:\n\nPower: Low voltage transformer with hospital grade power cord and plug.\n\nLine Voltage: 120 VAC, 60 Hz, 2 AMP circuit breaker; 230 VAC, 50 Hz, 1 AMP circuit breaker\n\nDimensions, size, capacity:\n\nMinimum articulating arm with a minimum of 34-inch vertical range of travel with a minimum of 220-degree collimator rotation.\n\nPrinciples of operation:\n\nMulti-Channel Analyzer:\n\nChannels: 1024\n\nSpectral Resolution: FWHM 8%\n\nCount Rate: (Maximum) 150,000 cps for Tc-99m\n\nCount Rate Stability: 99%\n\nGross Count Rate Linearity: Within 5% up to 150,000 cps\n\nPulse Height Linearity: Within 2% (independent of detector)\n\nDetector High Voltage Adjustment: Automatic adjustment for both probe and well; uses 10 μCi Cs-137 as the calibration source.\n\nRestrictive environmental conditions: User Set: Unlimited user defined Isotopes, setting ROI, half-life, name, efficiency and range.\n\nIntended use:\n\nFactory Programmed: Au-198, Ba-133, Co-57, Co-58, Co-60, Cr-51, Cs-137, F-18, Fe-59, Ga-67, Ga-68, Gd-153, Ge-68/Ga-68, Hg-197, I-123, I-125, I-131, In-111, Ir-192, K-42, Lu-177, Na-22, Na-24, Pd-103, Ra-223, Se-75, Sr-85, Tc-99m, Tc-99m/Tl-201, Tl-201, Yb-169, Wide Window.\n\nEquipment with which the item is used, Job related tools:\n\nProbe: 2\" x 2\" Nal (Tl) integral line scintillation detector\n\nOther pertinent information that describes the item, material or service required:\n\nUptake Stand:\n\nDimensions:\n\nArm down and retracted: 34\" l x 26\" w x 55\" h (86.4 x 66 x 139.7 cm)\n\nMaximum Height: 60\" (152.4 cm)\n\nMaximum Length: Arm Extended: 61\" (154.9 cm)\n\nCollimated Shield: Flat field collimator meeting IAEA specifications\n\nPositioning: Distance bar and positioning light\n\nCasters: 4\" Total locking\n\nMaximum weigh of 300 lbs.\n\nA maximum combined weight with Well Counter: 350 lbs.\n\nPower: Low voltage transformer with hospital grade power cord and plug.\n\nLine Voltage: 120 VAC, 60 Hz, 2 AMP circuit breaker; 230 VAC, 50 Hz, 1 AMP circuit breaker\n\nOTHER UNIQUE REQUIREMENTS: Minimum of two-inch well container\n\nCompatibility with Existing Equipment: TRM Compliance with VA Directives\n\nWINDOWS 10 compatible or Newest Windows Version compliance with VHA standards.\n\nMust be DICOM compliance, Directives or IT Policies, Required.\n\nCoordination with On-going Construction Project (provide the project number): N/A\n\nWarranty: 1 year from date of receipt and verification of installation/operation. Two years part/labor warranty\n\nTraining: Initial installation and launch training staff and service support\n\nService and/or Maintenance: Preventive maintenance and training support, to include two Operating Manuals and two Service Manuals\n\nSafety/ISO/IT/BioMed/SPS & Other Departmental Compliance: Must meet Technical Reference Model (TRM) VA/BioMed Compliance.\n\nD. DELIVERY\n\nContractor must deliver all components of the system within 30 days of award notice.\n\nStandard FOB Destination to:\n\nJohn J. Pershing VA Medical Center\n\n1500 North Westwood Blvd\n\nPoplar Bluff MO 63901\n\nGovernment-Furnished Property, Material, Equipment, or Information (GFP, GFM, GFE, or GFI) N/A\n\nSECURITY N/A\n\nSPECIAL MATERIAL REQUIREMENT: Two Operator’s Manuals and two Service Manuals\n\nE. PLACE OF PERFORMANCE\n\nThe system will be installed, serviced, and updated at the facility, John J. Pershing VAMC, Poplar Bluff, MO, Nuclear Medicine Department. Servicing, training, and support of personnel will be per stipulations on the final contract.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C25525Q0328","place_of_performance":{"zip":"63901","city":{"code":"59096","name":"Poplar Bluff"},"state":{"code":"MO","name":"Missouri"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6515"}],"due_at":"2025-05-16T16:00:00Z","due_date":"2025-05-16","closes_at":"2025-05-16T16:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","state":"MO","county":"29023","county_name":"Butler County","city":"2959096","city_name":"Poplar Bluff","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"GZT6NJ8HJLC3","amount":null,"linked_awards":1,"cancelled":false,"archived":true,"updated_at":"2026-11-15T09:55:06.689350Z","principal_notice_id":"c8aed55f45714c4ea51fe0d57b35e8cd","description":{"text":"STATEMENT OF REQUIREMENT\n\nA. GENERAL INFORMATION\n\nThe Nuclear Medicine service at John J. Pershing VA Medical Center (VAMC) in Poplar Bluff, MO will better serve its Veterans by acquiring this Thyroid Uptake System with Well Counting System with 2 Inch Well Shielding, a multi-purpose spectrum analysis instrument designed for diverse nuclear medicine applications. The system performs Uptake studies, wipe tests, and other user-defined tasks that are accomplished with speed and precision using this fully integrated computer-controlled instrument and its comprehensive selection of application software.\n\nEngineered for mobility, durability and operational efficiency, the unit handles clinical tests, safety compliance tasks, and system administration procedures quickly and accurately. Built-in menus follow conventionally established nuclear medicine procedures, providing step-by-step guidance throughout defined procedures. The system automatically performs calculations, stores patient information and test results, and outputs clear, concise reports. User-defined uptake protocols can be initiated.\n\nB. SCOPE\n\nDelivery of the Thyroid Uptake system will allow a bioassay program for quick and efficient measurement of the staff thyroid burden for radiopharmaceuticals, I-123, I-125 and I-131. Measurement results can be reported in cpm, dpm, uCi, or Bq. Action levels may be set by the user for each isotope. System reporting facilitates single bioassay report, summary of multiple bioassays on an individual staff member, and summary report on multiple staff members. Reports are easily printed or saved as PDF files\n\nThe Thyroid Uptake program supports multiple time-stamped uptake measurements, auto decay correction, user-defined uptake protocols, on-screen spectrum acquisition and analysis. The system provides reports that include normal ranges and allow notes/comments entered by the facility physician and technologists.\n\nThe wipe test application automatically calculates net contamination levels and reports results in dpm, uCi and Bq. The program allows compliance with regulations for counting and reporting results of wipes taken for contamination surveys. The system allows user to define an unlimited number of “Area” names and wipe “Locations” entered within the areas for testing and documentation. Each area may be designated as “restricted”, “unrestricted”, “package” or “sealed source”. The user may specify count times, activity units, wide window, and individual isotopes and geometric efficiencies or simply utilize the wide range of factory default options.\n\nThe program displays and stores the full spectrum with each wipe, automatically calculates net contamination levels and reports results in dpm, uCi or Bq. Wipes above the user defined trigger levels are easily identified. A detailed spectrum analysis may\n\nalso be performed for any wipe to help identify isotopes causing contamination. Customized reports can be printed or saved in PDF format.\n\nThe application specialist will provide training and guidance to ensure safe use of the equipment and the study and administration applications provided. The contractor will provide cybersecurity best practices information and training, when applicable.\n\nThe contractor will provide application update to ensure information security in the current equipment and other factors that interconnects with the imaging system including the network, other current peripheral applications and other new tools and software that will be developed or installed to work with the current work station and imaging equipment hardware and software.\n\nC. REQUIREMENT/SALIENT CHARACTERISTICS/SPECIFICATIONS\n\nCommon Nomenclature: Medical Spectrometer Hardware\n\nKind of material: ALL IN ONE Touch Screen Computer\n\nElectrical Data:\n\nPower: Low voltage transformer with hospital grade power cord and plug.\n\nLine Voltage: 120 VAC, 60 Hz, 2 AMP circuit breaker; 230 VAC, 50 Hz, 1 AMP circuit breaker\n\nDimensions, size, capacity:\n\nMinimum articulating arm with a minimum of 34-inch vertical range of travel with a minimum of 220-degree collimator rotation.\n\nPrinciples of operation:\n\nMulti-Channel Analyzer:\n\nChannels: 1024\n\nSpectral Resolution: FWHM 8%\n\nCount Rate: (Maximum) 150,000 cps for Tc-99m\n\nCount Rate Stability: 99%\n\nGross Count Rate Linearity: Within 5% up to 150,000 cps\n\nPulse Height Linearity: Within 2% (independent of detector)\n\nDetector High Voltage Adjustment: Automatic adjustment for both probe and well; uses 10 μCi Cs-137 as the calibration source.\n\nRestrictive environmental conditions: User Set: Unlimited user defined Isotopes, setting ROI, half-life, name, efficiency and range.\n\nIntended use:\n\nFactory Programmed: Au-198, Ba-133, Co-57, Co-58, Co-60, Cr-51, Cs-137, F-18, Fe-59, Ga-67, Ga-68, Gd-153, Ge-68/Ga-68, Hg-197, I-123, I-125, I-131, In-111, Ir-192, K-42, Lu-177, Na-22, Na-24, Pd-103, Ra-223, Se-75, Sr-85, Tc-99m, Tc-99m/Tl-201, Tl-201, Yb-169, Wide Window.\n\nEquipment with which the item is used, Job related tools:\n\nProbe: 2\" x 2\" Nal (Tl) integral line scintillation detector\n\nOther pertinent information that describes the item, material or service required:\n\nUptake Stand:\n\nDimensions:\n\nArm down and retracted: 34\" l x 26\" w x 55\" h (86.4 x 66 x 139.7 cm)\n\nMaximum Height: 60\" (152.4 cm)\n\nMaximum Length: Arm Extended: 61\" (154.9 cm)\n\nCollimated Shield: Flat field collimator meeting IAEA specifications\n\nPositioning: Distance bar and positioning light\n\nCasters: 4\" Total locking\n\nMaximum weigh of 300 lbs.\n\nA maximum combined weight with Well Counter: 350 lbs.\n\nPower: Low voltage transformer with hospital grade power cord and plug.\n\nLine Voltage: 120 VAC, 60 Hz, 2 AMP circuit breaker; 230 VAC, 50 Hz, 1 AMP circuit breaker\n\nOTHER UNIQUE REQUIREMENTS: Minimum of two-inch well container\n\nCompatibility with Existing Equipment: TRM Compliance with VA Directives\n\nWINDOWS 10 compatible or Newest Windows Version compliance with VHA standards.\n\nMust be DICOM compliance, Directives or IT Policies, Required.\n\nCoordination with On-going Construction Project (provide the project number): N/A\n\nWarranty: 1 year from date of receipt and verification of installation/operation. Two years part/labor warranty\n\nTraining: Initial installation and launch training staff and service support\n\nService and/or Maintenance: Preventive maintenance and training support, to include two Operating Manuals and two Service Manuals\n\nSafety/ISO/IT/BioMed/SPS & Other Departmental Compliance: Must meet Technical Reference Model (TRM) VA/BioMed Compliance.\n\nD. DELIVERY\n\nContractor must deliver all components of the system within 30 days of award notice.\n\nStandard FOB Destination to:\n\nJohn J. Pershing VA Medical Center\n\n1500 North Westwood Blvd\n\nPoplar Bluff MO 63901\n\nGovernment-Furnished Property, Material, Equipment, or Information (GFP, GFM, GFE, or GFI) N/A\n\nSECURITY N/A\n\nSPECIAL MATERIAL REQUIREMENT: Two Operator’s Manuals and two Service Manuals\n\nE. PLACE OF PERFORMANCE\n\nThe system will be installed, serviced, and updated at the facility, John J. Pershing VAMC, Poplar Bluff, MO, Nuclear Medicine Department. Servicing, training, and support of personnel will be per stipulations on the final contract.","html":"<p>STATEMENT OF REQUIREMENT<br />\nA. GENERAL INFORMATION<br />\nThe Nuclear Medicine service at John J. Pershing VA Medical Center (VAMC) in Poplar Bluff, MO will better serve its Veterans by acquiring this Thyroid Uptake System with Well Counting System with 2 Inch Well Shielding, a multi-purpose spectrum analysis instrument designed for diverse nuclear medicine applications. The system performs Uptake studies, wipe tests, and other user-defined tasks that are accomplished with speed and precision using this fully integrated computer-controlled instrument and its comprehensive selection of application software.<br />\nEngineered for mobility, durability and operational efficiency, the unit handles clinical tests, safety compliance tasks, and system administration procedures quickly and accurately. Built-in menus follow conventionally established nuclear medicine procedures, providing step-by-step guidance throughout defined procedures. The system automatically performs calculations, stores patient information and test results, and outputs clear, concise reports. User-defined uptake protocols can be initiated.<br />\nB. SCOPE<br />\nDelivery of the Thyroid Uptake system will allow a bioassay program for quick and efficient measurement of the staff thyroid burden for radiopharmaceuticals, I-123, I-125 and I-131. Measurement results can be reported in cpm, dpm, uCi, or Bq. Action levels may be set by the user for each isotope. System reporting facilitates single bioassay report, summary of multiple bioassays on an individual staff member, and summary report on multiple staff members. Reports are easily printed or saved as PDF files<br />\nThe Thyroid Uptake program supports multiple time-stamped uptake measurements, auto decay correction, user-defined uptake protocols, on-screen spectrum acquisition and analysis. The system provides reports that include normal ranges and allow notes/comments entered by the facility physician and technologists.<br />\nThe wipe test application automatically calculates net contamination levels and reports results in dpm, uCi and Bq. The program allows compliance with regulations for counting and reporting results of wipes taken for contamination surveys. The system allows user to define an unlimited number of &ldquo;Area&rdquo; names and wipe &ldquo;Locations&rdquo; entered within the areas for testing and documentation. Each area may be designated as &ldquo;restricted&rdquo;, &ldquo;unrestricted&rdquo;, &ldquo;package&rdquo; or &ldquo;sealed source&rdquo;. The user may specify count times, activity units, wide window, and individual isotopes and geometric efficiencies or simply utilize the wide range of factory default options.<br />\nThe program displays and stores the full spectrum with each wipe, automatically calculates net contamination levels and reports results in dpm, uCi or Bq. Wipes above the user defined trigger levels are easily identified. A detailed spectrum analysis may<br />\nalso be performed for any wipe to help identify isotopes causing contamination. Customized reports can be printed or saved in PDF format.<br />\nThe application specialist will provide training and guidance to ensure safe use of the equipment and the study and administration applications provided. The contractor will provide cybersecurity best practices information and training, when applicable.<br />\nThe contractor will provide application update to ensure information security in the current equipment and other factors that interconnects with the imaging system including the network, other current peripheral applications and other new tools and software that will be developed or installed to work with the current work station and imaging equipment hardware and software.<br />\nC. REQUIREMENT/SALIENT CHARACTERISTICS/SPECIFICATIONS<br />\nCommon Nomenclature: Medical Spectrometer Hardware<br />\nKind of material: ALL IN ONE Touch Screen Computer<br />\nElectrical Data:<br />\nPower: Low voltage transformer with hospital grade power cord and plug.<br />\nLine Voltage: 120 VAC, 60 Hz, 2 AMP circuit breaker; 230 VAC, 50 Hz, 1 AMP circuit breaker<br />\nDimensions, size, capacity:<br />\nMinimum articulating arm with a minimum of 34-inch vertical range of travel with a minimum of 220-degree collimator rotation.<br />\nPrinciples of operation:<br />\nMulti-Channel Analyzer:<br />\nChannels: 1024<br />\nSpectral Resolution: FWHM 8%<br />\nCount Rate: (Maximum) 150,000 cps for Tc-99m<br />\nCount Rate Stability: 99%<br />\nGross Count Rate Linearity: Within 5% up to 150,000 cps<br />\nPulse Height Linearity: Within 2% (independent of detector)<br />\nDetector High Voltage Adjustment: Automatic adjustment for both probe and well; uses 10 &mu;Ci Cs-137 as the calibration source.<br />\nRestrictive environmental conditions: User Set: Unlimited user defined Isotopes, setting ROI, half-life, name, efficiency and range.<br />\nIntended use:<br />\nFactory Programmed: Au-198, Ba-133, Co-57, Co-58, Co-60, Cr-51, Cs-137, F-18, Fe-59, Ga-67, Ga-68, Gd-153, Ge-68/Ga-68, Hg-197, I-123, I-125, I-131, In-111, Ir-192, K-42, Lu-177, Na-22, Na-24, Pd-103, Ra-223, Se-75, Sr-85, Tc-99m, Tc-99m/Tl-201, Tl-201, Yb-169, Wide Window.<br />\nEquipment with which the item is used, Job related tools:<br />\nProbe: 2&quot; x 2&quot; Nal (Tl) integral line scintillation detector<br />\nOther pertinent information that describes the item, material or service required:<br />\nUptake Stand:<br />\nDimensions:<br />\nArm down and retracted: 34&quot; l x 26&quot; w x 55&quot; h (86.4 x 66 x 139.7 cm)<br />\nMaximum Height: 60&quot; (152.4 cm)<br />\nMaximum Length: Arm Extended: 61&quot; (154.9 cm)<br />\nCollimated Shield: Flat field collimator meeting IAEA specifications<br />\nPositioning: Distance bar and positioning light<br />\nCasters: 4&quot; Total locking<br />\nMaximum weigh of 300 lbs.<br />\nA maximum combined weight with Well Counter: 350 lbs.<br />\nPower: Low voltage transformer with hospital grade power cord and plug.<br />\nLine Voltage: 120 VAC, 60 Hz, 2 AMP circuit breaker; 230 VAC, 50 Hz, 1 AMP circuit breaker<br />\nOTHER UNIQUE REQUIREMENTS: Minimum of two-inch well container<br />\nCompatibility with Existing Equipment: TRM Compliance with VA Directives<br />\nWINDOWS 10 compatible or Newest Windows Version compliance with VHA standards.<br />\nMust be DICOM compliance, Directives or IT Policies, Required.<br />\nCoordination with On-going Construction Project (provide the project number): N/A<br />\nWarranty: 1 year from date of receipt and verification of installation/operation. Two years part/labor warranty<br />\nTraining: Initial installation and launch training staff and service support<br />\nService and/or Maintenance: Preventive maintenance and training support, to include two Operating Manuals and two Service Manuals<br />\nSafety/ISO/IT/BioMed/SPS &amp; Other Departmental Compliance: Must meet Technical Reference Model (TRM) VA/BioMed Compliance.<br />\nD. DELIVERY<br />\nContractor must deliver all components of the system within 30 days of award notice.<br />\nStandard FOB Destination to:<br />\nJohn J. Pershing VA Medical Center<br />\n1500 North Westwood Blvd<br />\nPoplar Bluff MO 63901<br />\nGovernment-Furnished Property, Material, Equipment, or Information (GFP, GFM, GFE, or GFI) N/A<br />\nSECURITY N/A<br />\nSPECIAL MATERIAL REQUIREMENT: Two Operator&rsquo;s Manuals and two Service Manuals<br />\nE. PLACE OF PERFORMANCE<br />\nThe system will be installed, serviced, and updated at the facility, John J. Pershing VAMC, Poplar Bluff, MO, Nuclear Medicine Department. Servicing, training, and support of personnel will be per stipulations on the final contract.</p>","origin":"detail"},"contacts":[{"name":"Tywanna Sparks","role":"primary","email":"tywanna.sparks@va.gov","phone":"9137589928"}],"place_of_performance":{"zip":"63901","city":{"code":"59096","name":"Poplar Bluff"},"state":{"code":"MO","name":"Missouri"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"66048","city":"LEAVENWORTH","state":"KS","country":"USA"},"naics_codes":["334510"],"award":null,"attachments":[{"resource_id":"a825ea5ba6ad4aeabd7d5d59b0f20fc5","name":"36C25525Q0328.pdf","kind":"file","mime_type":".pdf","size_bytes":545890,"posted_at":"2025-05-09T13:34:00.579Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/a825ea5ba6ad4aeabd7d5d59b0f20fc5/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C25525P0332_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C25525P0332_3600_-NONE-_-NONE-/","piid":"36C25525P0332","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"GZT6NJ8HJLC3","recipient_name":"DGA MEDICAL LLC","recipient_uei":"GZT6NJ8HJLC3","recipient_cage":"39VR1","recipient_city":"PHOENIX","recipient_state":"AZ","sub_name":"Department of Veterans Affairs","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","office_key":"o-36C255","first_action_date":"2025-06-11","last_action_date":"2025-06-11","actions":1,"obligated":"34933.00","current_total_value":"34933.00","potential_total_value":"34933.00","naics":"334510","psc":"6515","extent_competed":"COMPETED UNDER SAP","set_aside":"SERVICE DISABLED VETERAN OWNED SMALL BUSINESS SET-ASIDE","offers_received":1,"description":"THYROID UPTAKE SYSTEM","method":"solicitation","confidence":"high","evidence":["solicitation number 36C25525Q0328 equals the FPDS solicitation identifier","same awarding office 36C255"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C25527R0016","latest_notice_id":"a7eee67b427c47158525b1a79fc8ecd2","title":"Z2DA--657-24-102JC - Prepare Site for New PET/CT, Room A011D (MD) FY27 NRM VISN Base, CON (VA-27-00017492) 657-27-1-8434-0001","solicitation_number":"36C25527R0016","notice_type":"p","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"236220","psc":"Z2DA","set_aside":"SDVOSBC","state":"MO","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"WORK: THE GENERAL DESCRIPTION: VA SAINT LOUIS HEALTH CARE SYSTEM","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C25526Q0617","latest_notice_id":"3506983a2af048deaf442eae0f8b8a04","title":"H112--Annual/Sem-i annual fire smoke inspections and auto door services l EKH","solicitation_number":"36C25526Q0617","notice_type":"o","first_type":"r","first_posted":"2026-08-19","last_posted":"2026-11-18","notices":11,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"541350","psc":"H112","set_aside":"SBA","state":"KS","county":"20103","county_name":"Leavenworth County","city":"2039000","city_name":"Leavenworth","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C25527Q0057","latest_notice_id":"fbd76a4c366d45e896674756383b4fb2","title":"C222--589-27-108, Correct Electrical Deficiencies in Building 26 KCVA (ME) FY27 NRM VISN Base - AE (VA-27-00021035)","solicitation_number":"36C25527Q0057","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":2,"due_at":"2026-12-01T20:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"541330","psc":"C222","set_aside":"EDWOSB","state":"MO","county":"29095","county_name":"Jackson County","city":"2938000","city_name":"Kansas City","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T09:15:14.204648Z"},{"key":"36C25527Q00571","latest_notice_id":"53c5d2376d9e4fb79d39a712a62deb10","title":"C222--589-27-108, Correct Electrical Deficiencies in Building 26 KCVA (ME) FY27 NRM VISN Base - AE (VA-27-00021035)","solicitation_number":"36C25527Q0057_1","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-12-01T20:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"541330","psc":"C222","set_aside":"SDVOSBC","state":"MO","county":"29095","county_name":"Jackson County","city":"2938000","city_name":"Kansas City","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C25527Q0053","latest_notice_id":"f87b14f3ce2643d69bdc633c0b05a712","title":"J065--Imaging Service & Maintenance EHCC & MTV","solicitation_number":"36C25527Q0053","notice_type":"o","first_type":"p","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":2,"due_at":"2026-12-02T14:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"811210","psc":"J065","set_aside":null,"state":"IN","county":"18163","county_name":"Vanderburgh County","city":"1822000","city_name":"Evansville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open":[{"key":"75N98027Q00094","latest_notice_id":"fe80b99f89894110b18ddb4d826a2131","title":"NCSS - Sentec tCOM+ Transcutaneous CO2 Monitor Acq","solicitation_number":"75N98027Q00094","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T16:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334510","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C26327Q0131","latest_notice_id":"885e687dd48e45c295666a91fc27da2b","title":"6515--Medtronic FT10 Series Cauterizer","solicitation_number":"36C26327Q0131","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-30T16:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C263","office_name":"NETWORK CONTRACT OFFICE 23 (36C263)","naics":"334510","psc":"6515","set_aside":"SDVOSBC","state":"ND","county":"38017","county_name":"Cass County","city":"3825700","city_name":"Fargo","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T07:05:05.540398Z"},{"key":"36C24827Q0085","latest_notice_id":"deec231df02144f98098a3d7c681c25c","title":"W065--FY27 Mobile CT Scanner Lease","solicitation_number":"36C24827Q0085","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-30T21:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"334510","psc":"W065","set_aside":null,"state":"FL","county":"12095","county_name":"Orange County","city":"1253000","city_name":"Orlando","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-15T00:31:52.781180Z"}],"similar_open_total":11,"indexable":false}