{"canonical":"https://sealedbidder.com/opportunities/36c25525q0268","key":"36C25525Q0268","url":"https://sealedbidder.com/opportunities/36c25525q0268","title":"6515--HEART BYPASS MACHINE - ECMO","solicitation_number":"36C25525Q0268","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-03-31T16:00:00Z","first_posted":"2025-03-17","last_posted":"2025-03-17","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"334510","psc":"6515","set_aside":"SBA","place_state":"MO","place_scope":"nationwide","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"29019","place_county_name":"Boone County","place_city":"2915670","place_city_name":"Columbia","winner":null,"award_amount":null,"publications":[{"notice_id":"d9ec8757a2f64902ab1cd11b34b7c20c","title":"6515--HEART BYPASS MACHINE - ECMO","solicitation_number":"36C25525Q0268","notice_type":"r","base_type":"r","posted":"2025-03-17","posted_at":"2025-03-17T18:08:04.793Z","due_at":"2025-03-31T16:00:00Z","due_date":"2025-03-31","cancelled":false,"archived":true,"archive_date":"2025-04-10","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/d9ec8757a2f64902ab1cd11b34b7c20c/view","enriched":true,"history":[{"index":3,"title":"6515--HEART BYPASS MACHINE - ECMO","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-17T18:08:04.793Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"d9ec8757a2f64902ab1cd11b34b7c20c","solicitation_number":"36C25525Q0268"}]}],"latest_notice_id":"d9ec8757a2f64902ab1cd11b34b7c20c","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-03-17","posted_at":"2025-03-17T18:08:04.793Z","created_at":"2025-03-17T18:08:03.661Z","modified_at":"2025-04-11T04:04:30.157Z","response_deadline":{"raw":"2025-03-31T11:00:00-05:00","utc":"2025-03-31T16:00:00Z","date":"2025-03-31","time":"11:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/d9ec8757a2f64902ab1cd11b34b7c20c/view"},"naics":{"codes":["334510"],"primary":"334510"},"title":"6515--HEART BYPASS MACHINE - ECMO","agency":{"office":{"code":"36C255","name":"255-NETWORK CONTRACT OFFICE 15 (36C255)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"66048","city":"LEAVENWORTH","state":"KS","country":"USA"},"organization_id":"100186523","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-04-10","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--HEART BYPASS MACHINE - ECMO","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-17T18:08:04.793Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"d9ec8757a2f64902ab1cd11b34b7c20c","solicitation_number":"36C25525Q0268"}],"contacts":[{"name":"Betty Flores","role":"primary","email":"veronica.flores@va.gov","phone":"9139461167","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"d9ec8757a2f64902ab1cd11b34b7c20c","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"d9ec8757a2f64902ab1cd11b34b7c20c","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-20T08:40:46.040806728Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"e08235b43fac7d9496bc24a54121ba5976e0ee8f6efb809dee1666682914055d","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-20T08:40:46.040806728Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"This is a SOURCES SOUGHT announcement only. It is neither a solicitation announcement nor a request for proposal or quote and does not obligate the Government to award a contract. Responses to this Sources Sought must be in writing. The purpose of this Sources Sought Announcement is for market research, to make appropriate acquisition decisions, and to gain knowledge of potential qualified businesses capable of providing the following:\n\nHeart Bypass Machine for Columbia VAMC\n*** See Statement of Requirement below for details ***\n If this is within your capability, please respond with the information below: \nCompany Name \nAddress \nPoint of Contact \nPhone, Fax, and Email \nUEI number \nGSA Contract (as applicable)\nCapability Statement that clearly and convincingly identifies your ability to fulfill this requirement.\nBrochures of product being offered to include specifications. \nMeet the Buy American statute FAR 52.225-1 \nAuthorized distributor letter from OEM\nInterested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications to be considered for award. In addition, FAR 4.11 states that prospective contractors shall be registered in the System for Award Management (www.SAM.gov) database. All Service-Disabled Veteran Owned Small Businesses (SDVOSB) and Veteran Owned Small Businesses (VOSB) shall be verified in VetCert at https://veterans.certify.sba.gov\n \nPoint of Contact for this Sources Sought is: \nveronica.flores@va.gov\nDepartment of Veterans Affairs\nNetwork Contracting Office -15\n3450 S. 4th Street Trafficway\nLeavenworth, KS. 66048Â  \n\n\n\nSTATEMENT OF REQUIREMENTS \n\n\nGENERAL INFORMATION \n\n1.0 Scope of Work:  Harry S Truman VA Hospital (HSTVA) needs new life saving equipment. This equipment is a heart bypass machine. HSTVA current Marquet systems are more than 10 years old and need to be replaced. HSTVA is requiring three new heart bypass machines to replace the Marquet system. The components of the heart bypass need to include a Pump, Oxygenator, Heat exchanger, cannulas, and tubing. The system shall be an S5 or newer version of the Heat pump or equal characteristics.\n\n2.0 Background:  The current system in place is a Livanova Marquet S1 system. This system is past its end of life and an S5 or newer system or equal needs to be procured. \n\nCONTRACTOR REQUIREMENTS \n\n3.0 Technical Requirements/Tasks:  \n\nThe system shall be able to do the following:\nShall have a five roller pumps and a monitoring system. The system shall consist of, Roller pumps, double roller pumps, a centrifugal pump, and a system panel. Each roller pump shall have an independent touchscreen control panel that can be adjusted using a knob to set the speed of the electronics in the pump. \nShall be able to be rolled around as a cart.\nEach pump shall be controlled individually:Â 1 knob = 1 pump\nThe cockpit and the Patient Monitor shall be connected but operate separately\nRedundant and individual safety mechanisms\nAutomated sensor checks\nIntegrated warning system based on user-defined thresholds\nA patient monitor with embedded clinical logic to support data-driven clinical decisions, this monitor shall report all the metabolic information. \nShall integrate with HSTVA EMR system, Computerized Patient Record System (CPRS), Veterans Health Information Systems and Technology Architecture (VISTA), and Oracle.\nShall have an advanced cable management system and cockpit that provides one central view and control.\n\nAn ECMO machine primarily consists ofÂ a mechanical blood pump, a membrane oxygenator (artificial lung), a heat exchanger to regulate blood temperature, and tubing connecting to cannulas (large tubes)Â that are inserted into the patient's veins and arteries, allowing the machine to draw blood out, oxygenate it, remove carbon dioxide, and then return it to the body;Â essentially acting as a temporary replacement for the heart and lungs when they cannot function adequately.\n\nThe ECMO machine shall include:\nPump:\nThis component forcefully pushes the patient's blood through the circuit.\nOxygenator (membrane lung):\nThis is where gas exchange occurs, adding oxygen and removing carbon dioxide from the blood.\nHeat exchanger:\nEnsures the blood is warmed to the patient's body temperature before being returned.\nCannulas:\nLarge tubes inserted into the patient's blood vessels, one to draw blood out and another to return oxygenated blood.\nTubing:\nConnects the cannulas to the pump and oxygenator, allowing blood to flow through the circuit.\n\n5.0 Deliverables / Schedule: \n Deliverables of this system should be shipped to\n800 Hospital Dr Columbia MO 65201. ATT: Warehouse foreman, \n All equipment and components shall be shipped together. \nAll equipment and components shall be tracked upon shipment and tracking number give to the POC.  \n\n6.0 Training:  Travel for training and install shall be done by vendor after the delivery receipt of the equipment. No additional fees shall be incurred outside the quote. Any fees shall be identified in the quote of the procurement not noted later. The vendor shall handle all traveling to meet the needs of installation and training. \n Vendor shall provide training and installation of equipment with local Biomedical rep from HSTVA to ensure equipment is working properly. \n\n7.0 Data Rights: All rights and admin privileges shall be handed over to HSTVA upon install of equipment.","text":"This is a SOURCES SOUGHT announcement only. It is neither a solicitation announcement nor a request for proposal or quote and does not obligate the Government to award a contract. Responses to this Sources Sought must be in writing. The purpose of this Sources Sought Announcement is for market research, to make appropriate acquisition decisions, and to gain knowledge of potential qualified businesses capable of providing the following:\n\nHeart Bypass Machine for Columbia VAMC\n*** See Statement of Requirement below for details ***\nIf this is within your capability, please respond with the information below:\nCompany Name\nAddress\nPoint of Contact\nPhone, Fax, and Email\nUEI number\nGSA Contract (as applicable)\nCapability Statement that clearly and convincingly identifies your ability to fulfill this requirement.\nBrochures of product being offered to include specifications.\nMeet the Buy American statute FAR 52.225-1\nAuthorized distributor letter from OEM\nInterested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications to be considered for award. In addition, FAR 4.11 states that prospective contractors shall be registered in the System for Award Management (www.SAM.gov) database. All Service-Disabled Veteran Owned Small Businesses (SDVOSB) and Veteran Owned Small Businesses (VOSB) shall be verified in VetCert at https://veterans.certify.sba.gov\n\nPoint of Contact for this Sources Sought is:\nveronica.flores@va.gov\nDepartment of Veterans Affairs\nNetwork Contracting Office -15\n3450 S. 4th Street Trafficway\nLeavenworth, KS. 66048Â\n\nSTATEMENT OF REQUIREMENTS\n\nGENERAL INFORMATION\n\n1.0 Scope of Work: Harry S Truman VA Hospital (HSTVA) needs new life saving equipment. This equipment is a heart bypass machine. HSTVA current Marquet systems are more than 10 years old and need to be replaced. HSTVA is requiring three new heart bypass machines to replace the Marquet system. The components of the heart bypass need to include a Pump, Oxygenator, Heat exchanger, cannulas, and tubing. The system shall be an S5 or newer version of the Heat pump or equal characteristics.\n\n2.0 Background: The current system in place is a Livanova Marquet S1 system. This system is past its end of life and an S5 or newer system or equal needs to be procured.\n\nCONTRACTOR REQUIREMENTS\n\n3.0 Technical Requirements/Tasks:\n\nThe system shall be able to do the following:\nShall have a five roller pumps and a monitoring system. The system shall consist of, Roller pumps, double roller pumps, a centrifugal pump, and a system panel. Each roller pump shall have an independent touchscreen control panel that can be adjusted using a knob to set the speed of the electronics in the pump.\nShall be able to be rolled around as a cart.\nEach pump shall be controlled individually:Â 1 knob = 1 pump\nThe cockpit and the Patient Monitor shall be connected but operate separately\nRedundant and individual safety mechanisms\nAutomated sensor checks\nIntegrated warning system based on user-defined thresholds\nA patient monitor with embedded clinical logic to support data-driven clinical decisions, this monitor shall report all the metabolic information.\nShall integrate with HSTVA EMR system, Computerized Patient Record System (CPRS), Veterans Health Information Systems and Technology Architecture (VISTA), and Oracle.\nShall have an advanced cable management system and cockpit that provides one central view and control.\n\nAn ECMO machine primarily consists ofÂ a mechanical blood pump, a membrane oxygenator (artificial lung), a heat exchanger to regulate blood temperature, and tubing connecting to cannulas (large tubes)Â that are inserted into the patient's veins and arteries, allowing the machine to draw blood out, oxygenate it, remove carbon dioxide, and then return it to the body;Â essentially acting as a temporary replacement for the heart and lungs when they cannot function adequately.\n\nThe ECMO machine shall include:\nPump:\nThis component forcefully pushes the patient's blood through the circuit.\nOxygenator (membrane lung):\nThis is where gas exchange occurs, adding oxygen and removing carbon dioxide from the blood.\nHeat exchanger:\nEnsures the blood is warmed to the patient's body temperature before being returned.\nCannulas:\nLarge tubes inserted into the patient's blood vessels, one to draw blood out and another to return oxygenated blood.\nTubing:\nConnects the cannulas to the pump and oxygenator, allowing blood to flow through the circuit.\n\n5.0 Deliverables / Schedule:\nDeliverables of this system should be shipped to\n800 Hospital Dr Columbia MO 65201. ATT: Warehouse foreman,\nAll equipment and components shall be shipped together.\nAll equipment and components shall be tracked upon shipment and tracking number give to the POC.\n\n6.0 Training: Travel for training and install shall be done by vendor after the delivery receipt of the equipment. No additional fees shall be incurred outside the quote. Any fees shall be identified in the quote of the procurement not noted later. The vendor shall handle all traveling to meet the needs of installation and training.\nVendor shall provide training and installation of equipment with local Biomedical rep from HSTVA to ensure equipment is working properly.\n\n7.0 Data Rights: All rights and admin privileges shall be handed over to HSTVA upon install of equipment.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25525Q0268","place_of_performance":{"zip":"65201-5275","city":{"name":"Columbia"},"state":{"name":"MO"},"street":"Department of Veterans Affairs Harry S. Truman Memorial Veterans Hospital","country":{"code":"USA","name":"UNITED STATES"},"street2":"800 Hospital Drive"},"product_service_code":"6515"}],"due_at":"2025-03-31T16:00:00Z","due_date":"2025-03-31","closes_at":"2025-03-31T16:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","state":"MO","county":"29019","county_name":"Boone County","city":"2915670","city_name":"Columbia","country":"USA","state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-20T08:45:02.113346Z","principal_notice_id":"d9ec8757a2f64902ab1cd11b34b7c20c","description":{"text":"This is a SOURCES SOUGHT announcement only. It is neither a solicitation announcement nor a request for proposal or quote and does not obligate the Government to award a contract. Responses to this Sources Sought must be in writing. The purpose of this Sources Sought Announcement is for market research, to make appropriate acquisition decisions, and to gain knowledge of potential qualified businesses capable of providing the following:\n\nHeart Bypass Machine for Columbia VAMC\n*** See Statement of Requirement below for details ***\nIf this is within your capability, please respond with the information below:\nCompany Name\nAddress\nPoint of Contact\nPhone, Fax, and Email\nUEI number\nGSA Contract (as applicable)\nCapability Statement that clearly and convincingly identifies your ability to fulfill this requirement.\nBrochures of product being offered to include specifications.\nMeet the Buy American statute FAR 52.225-1\nAuthorized distributor letter from OEM\nInterested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications to be considered for award. In addition, FAR 4.11 states that prospective contractors shall be registered in the System for Award Management (www.SAM.gov) database. All Service-Disabled Veteran Owned Small Businesses (SDVOSB) and Veteran Owned Small Businesses (VOSB) shall be verified in VetCert at https://veterans.certify.sba.gov\n\nPoint of Contact for this Sources Sought is:\nveronica.flores@va.gov\nDepartment of Veterans Affairs\nNetwork Contracting Office -15\n3450 S. 4th Street Trafficway\nLeavenworth, KS. 66048Â\n\nSTATEMENT OF REQUIREMENTS\n\nGENERAL INFORMATION\n\n1.0 Scope of Work: Harry S Truman VA Hospital (HSTVA) needs new life saving equipment. This equipment is a heart bypass machine. HSTVA current Marquet systems are more than 10 years old and need to be replaced. HSTVA is requiring three new heart bypass machines to replace the Marquet system. The components of the heart bypass need to include a Pump, Oxygenator, Heat exchanger, cannulas, and tubing. The system shall be an S5 or newer version of the Heat pump or equal characteristics.\n\n2.0 Background: The current system in place is a Livanova Marquet S1 system. This system is past its end of life and an S5 or newer system or equal needs to be procured.\n\nCONTRACTOR REQUIREMENTS\n\n3.0 Technical Requirements/Tasks:\n\nThe system shall be able to do the following:\nShall have a five roller pumps and a monitoring system. The system shall consist of, Roller pumps, double roller pumps, a centrifugal pump, and a system panel. Each roller pump shall have an independent touchscreen control panel that can be adjusted using a knob to set the speed of the electronics in the pump.\nShall be able to be rolled around as a cart.\nEach pump shall be controlled individually:Â 1 knob = 1 pump\nThe cockpit and the Patient Monitor shall be connected but operate separately\nRedundant and individual safety mechanisms\nAutomated sensor checks\nIntegrated warning system based on user-defined thresholds\nA patient monitor with embedded clinical logic to support data-driven clinical decisions, this monitor shall report all the metabolic information.\nShall integrate with HSTVA EMR system, Computerized Patient Record System (CPRS), Veterans Health Information Systems and Technology Architecture (VISTA), and Oracle.\nShall have an advanced cable management system and cockpit that provides one central view and control.\n\nAn ECMO machine primarily consists ofÂ a mechanical blood pump, a membrane oxygenator (artificial lung), a heat exchanger to regulate blood temperature, and tubing connecting to cannulas (large tubes)Â that are inserted into the patient's veins and arteries, allowing the machine to draw blood out, oxygenate it, remove carbon dioxide, and then return it to the body;Â essentially acting as a temporary replacement for the heart and lungs when they cannot function adequately.\n\nThe ECMO machine shall include:\nPump:\nThis component forcefully pushes the patient's blood through the circuit.\nOxygenator (membrane lung):\nThis is where gas exchange occurs, adding oxygen and removing carbon dioxide from the blood.\nHeat exchanger:\nEnsures the blood is warmed to the patient's body temperature before being returned.\nCannulas:\nLarge tubes inserted into the patient's blood vessels, one to draw blood out and another to return oxygenated blood.\nTubing:\nConnects the cannulas to the pump and oxygenator, allowing blood to flow through the circuit.\n\n5.0 Deliverables / Schedule:\nDeliverables of this system should be shipped to\n800 Hospital Dr Columbia MO 65201. ATT: Warehouse foreman,\nAll equipment and components shall be shipped together.\nAll equipment and components shall be tracked upon shipment and tracking number give to the POC.\n\n6.0 Training: Travel for training and install shall be done by vendor after the delivery receipt of the equipment. No additional fees shall be incurred outside the quote. Any fees shall be identified in the quote of the procurement not noted later. The vendor shall handle all traveling to meet the needs of installation and training.\nVendor shall provide training and installation of equipment with local Biomedical rep from HSTVA to ensure equipment is working properly.\n\n7.0 Data Rights: All rights and admin privileges shall be handed over to HSTVA upon install of equipment.","html":"This is a SOURCES SOUGHT announcement only. It is neither a solicitation announcement nor a request for proposal or quote and does not obligate the Government to award a contract. Responses to this Sources Sought must be in writing. The purpose of this Sources Sought Announcement is for market research, to make appropriate acquisition decisions, and to gain knowledge of potential qualified businesses capable of providing the following:\n\nHeart Bypass Machine for Columbia VAMC\n*** See Statement of Requirement below for details ***\n If this is within your capability, please respond with the information below: \nCompany Name \nAddress \nPoint of Contact \nPhone, Fax, and Email \nUEI number \nGSA Contract (as applicable)\nCapability Statement that clearly and convincingly identifies your ability to fulfill this requirement.\nBrochures of product being offered to include specifications. \nMeet the Buy American statute FAR 52.225-1 \nAuthorized distributor letter from OEM\nInterested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications to be considered for award. In addition, FAR 4.11 states that prospective contractors shall be registered in the System for Award Management (www.SAM.gov) database. All Service-Disabled Veteran Owned Small Businesses (SDVOSB) and Veteran Owned Small Businesses (VOSB) shall be verified in VetCert at https://veterans.certify.sba.gov\n \nPoint of Contact for this Sources Sought is: \nveronica.flores@va.gov\nDepartment of Veterans Affairs\nNetwork Contracting Office -15\n3450 S. 4th Street Trafficway\nLeavenworth, KS. 66048Â  \n\n\n\nSTATEMENT OF REQUIREMENTS \n\n\nGENERAL INFORMATION \n\n1.0 Scope of Work:  Harry S Truman VA Hospital (HSTVA) needs new life saving equipment. This equipment is a heart bypass machine. HSTVA current Marquet systems are more than 10 years old and need to be replaced. HSTVA is requiring three new heart bypass machines to replace the Marquet system. The components of the heart bypass need to include a Pump, Oxygenator, Heat exchanger, cannulas, and tubing. The system shall be an S5 or newer version of the Heat pump or equal characteristics.\n\n2.0 Background:  The current system in place is a Livanova Marquet S1 system. This system is past its end of life and an S5 or newer system or equal needs to be procured. \n\nCONTRACTOR REQUIREMENTS \n\n3.0 Technical Requirements/Tasks:  \n\nThe system shall be able to do the following:\nShall have a five roller pumps and a monitoring system. The system shall consist of, Roller pumps, double roller pumps, a centrifugal pump, and a system panel. Each roller pump shall have an independent touchscreen control panel that can be adjusted using a knob to set the speed of the electronics in the pump. \nShall be able to be rolled around as a cart.\nEach pump shall be controlled individually:Â 1 knob = 1 pump\nThe cockpit and the Patient Monitor shall be connected but operate separately\nRedundant and individual safety mechanisms\nAutomated sensor checks\nIntegrated warning system based on user-defined thresholds\nA patient monitor with embedded clinical logic to support data-driven clinical decisions, this monitor shall report all the metabolic information. \nShall integrate with HSTVA EMR system, Computerized Patient Record System (CPRS), Veterans Health Information Systems and Technology Architecture (VISTA), and Oracle.\nShall have an advanced cable management system and cockpit that provides one central view and control.\n\nAn ECMO machine primarily consists ofÂ a mechanical blood pump, a membrane oxygenator (artificial lung), a heat exchanger to regulate blood temperature, and tubing connecting to cannulas (large tubes)Â that are inserted into the patient's veins and arteries, allowing the machine to draw blood out, oxygenate it, remove carbon dioxide, and then return it to the body;Â essentially acting as a temporary replacement for the heart and lungs when they cannot function adequately.\n\nThe ECMO machine shall include:\nPump:\nThis component forcefully pushes the patient's blood through the circuit.\nOxygenator (membrane lung):\nThis is where gas exchange occurs, adding oxygen and removing carbon dioxide from the blood.\nHeat exchanger:\nEnsures the blood is warmed to the patient's body temperature before being returned.\nCannulas:\nLarge tubes inserted into the patient's blood vessels, one to draw blood out and another to return oxygenated blood.\nTubing:\nConnects the cannulas to the pump and oxygenator, allowing blood to flow through the circuit.\n\n5.0 Deliverables / Schedule: \n Deliverables of this system should be shipped to\n800 Hospital Dr Columbia MO 65201. ATT: Warehouse foreman, \n All equipment and components shall be shipped together. \nAll equipment and components shall be tracked upon shipment and tracking number give to the POC.  \n\n6.0 Training:  Travel for training and install shall be done by vendor after the delivery receipt of the equipment. No additional fees shall be incurred outside the quote. Any fees shall be identified in the quote of the procurement not noted later. The vendor shall handle all traveling to meet the needs of installation and training. \n Vendor shall provide training and installation of equipment with local Biomedical rep from HSTVA to ensure equipment is working properly. \n\n7.0 Data Rights: All rights and admin privileges shall be handed over to HSTVA upon install of equipment.","origin":"detail"},"contacts":[{"name":"Betty Flores","role":"primary","email":"veronica.flores@va.gov","phone":"9139461167","title":"Contracting Officer"}],"place_of_performance":{"zip":"65201-5275","city":{"name":"Columbia"},"state":{"name":"MO"},"street":"Department of Veterans Affairs Harry S. Truman Memorial Veterans Hospital","country":{"code":"USA","name":"UNITED STATES"},"street2":"800 Hospital Drive"},"office_address":{"zip":"66048","city":"LEAVENWORTH","state":"KS","country":"USA"},"naics_codes":["334510"],"award":{"awardee":{}},"attachments":[{"resource_id":"604317ca501b476e9337ed13bae8c722","name":"36C25525Q0268.docx","kind":"file","mime_type":".docx","size_bytes":27541,"posted_at":"2025-03-17T18:08:04.793Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/604317ca501b476e9337ed13bae8c722/download","mirrored":false}],"awards":[],"related":[{"key":"36C25527R0016","latest_notice_id":"a7eee67b427c47158525b1a79fc8ecd2","title":"Z2DA--657-24-102JC - Prepare Site for New PET/CT, Room A011D (MD) FY27 NRM VISN Base, CON (VA-27-00017492) 657-27-1-8434-0001","solicitation_number":"36C25527R0016","notice_type":"p","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"236220","psc":"Z2DA","set_aside":"SDVOSBC","state":"MO","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"WORK: THE GENERAL DESCRIPTION: VA SAINT LOUIS HEALTH CARE SYSTEM","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C25526Q0617","latest_notice_id":"3506983a2af048deaf442eae0f8b8a04","title":"H112--Annual/Sem-i annual fire smoke inspections and auto door services l EKH","solicitation_number":"36C25526Q0617","notice_type":"o","first_type":"r","first_posted":"2026-08-19","last_posted":"2026-11-18","notices":11,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"541350","psc":"H112","set_aside":"SBA","state":"KS","county":"20103","county_name":"Leavenworth County","city":"2039000","city_name":"Leavenworth","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C25527Q0057","latest_notice_id":"fbd76a4c366d45e896674756383b4fb2","title":"C222--589-27-108, Correct Electrical Deficiencies in Building 26 KCVA (ME) FY27 NRM VISN Base - AE (VA-27-00021035)","solicitation_number":"36C25527Q0057","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":2,"due_at":"2026-12-01T20:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"541330","psc":"C222","set_aside":"EDWOSB","state":"MO","county":"29095","county_name":"Jackson County","city":"2938000","city_name":"Kansas City","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T09:15:14.204648Z"},{"key":"36C25527Q00571","latest_notice_id":"53c5d2376d9e4fb79d39a712a62deb10","title":"C222--589-27-108, Correct Electrical Deficiencies in Building 26 KCVA (ME) FY27 NRM VISN Base - AE (VA-27-00021035)","solicitation_number":"36C25527Q0057_1","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-12-01T20:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"541330","psc":"C222","set_aside":"SDVOSBC","state":"MO","county":"29095","county_name":"Jackson County","city":"2938000","city_name":"Kansas City","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C25527Q0053","latest_notice_id":"f87b14f3ce2643d69bdc633c0b05a712","title":"J065--Imaging Service & Maintenance EHCC & MTV","solicitation_number":"36C25527Q0053","notice_type":"o","first_type":"p","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":2,"due_at":"2026-12-02T14:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"811210","psc":"J065","set_aside":null,"state":"IN","county":"18163","county_name":"Vanderburgh County","city":"1822000","city_name":"Evansville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open":[{"key":"75N98027Q00094","latest_notice_id":"fe80b99f89894110b18ddb4d826a2131","title":"NCSS - Sentec tCOM+ Transcutaneous CO2 Monitor Acq","solicitation_number":"75N98027Q00094","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T16:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334510","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C26327Q0131","latest_notice_id":"885e687dd48e45c295666a91fc27da2b","title":"6515--Medtronic FT10 Series Cauterizer","solicitation_number":"36C26327Q0131","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-30T16:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C263","office_name":"NETWORK CONTRACT OFFICE 23 (36C263)","naics":"334510","psc":"6515","set_aside":"SDVOSBC","state":"ND","county":"38017","county_name":"Cass County","city":"3825700","city_name":"Fargo","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T07:05:05.540398Z"},{"key":"36C24827Q0085","latest_notice_id":"deec231df02144f98098a3d7c681c25c","title":"W065--FY27 Mobile CT Scanner Lease","solicitation_number":"36C24827Q0085","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-30T21:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"334510","psc":"W065","set_aside":null,"state":"FL","county":"12095","county_name":"Orange County","city":"1253000","city_name":"Orlando","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-15T00:31:52.781180Z"}],"similar_open_total":11,"indexable":false}