Sources sought
Thyroid Uptake System, Poplar Bluff, MO VAMC
36C25525Q0265
Department of Veterans Affairs, 255-Network Contract Office 15. Surgical Appliance and Supplies Manufacturing.
Response deadline
March 20, 2025 at 12:00 PM EDT
Closed 616 days ago. Posted March 14, 2025. Scheduled to archive April 4, 2025.
Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities
This one closed in 2025
20 like it are open now in surgical appliance and supplies manufacturing
- SOURCES SOUGHT NOTICE FOR HEAD, SHOULDER, AND UPPER-EXTREMITY POSITIONING ACCESSORIES FOR THE MAQUET MEERA 7200 OPERATING TABLE
Department of Veterans Affairs, 260-Network Contract Office 20
Sources soughtNAICS 339113Ship to Spokane, WA36C26027Q0130Due tomorrowNov 27 - VALVE,BREATHING APP
Department of the Navy, NAVSUP Weapon Systems Support Mech
SolicitationNAICS 339113Ship to the buyerN0010427QLA17Due tomorrowNov 27 - 36C257-27-AP-0953 Prosthetic STX 671 O2 Equipment (VA-27-00016458)
Department of Veterans Affairs, 257-Network Contract Office 17
SolicitationSDVOSBNAICS 339113Ship to San Antonio, TX36C25727Q0104Due in 4 daysNov 30
All 20 open in surgical appliance and supplies manufacturing
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 339113 (surgical appliance and supplies manufacturing), means no more than 800 employees, counted with affiliates. What a set-aside is
- What comes next
- No solicitation was published under this number after the sources sought of March 14, 2025. An agency sometimes issues the solicitation under a new number.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
Statement of Requirement
Thyroid Uptake Unit
John J. Pershing VA Medical Center
- GENERAL INFORMATION
The Nuclear Medicine service at John J. Pershing VA Medical Center (VAMC) in Poplar Bluff, MO will better serve its Veterans by acquiring this Thyroid Uptake System with Well Counting System with 2 Inch Well Shielding, a multi-purpose spectrum analysis instrument designed for diverse nuclear medicine applications. The system performs Uptake studies, wipe tests, and other user-defined tasks that are accomplished with speed and precision using this fully integrated computer-controlled instrument and its comprehensive selection of application software.
Engineered for mobility, durability and operational efficiency, the unit handles clinical tests, safety compliance tasks, and system administration procedures quickly and accurately. Built-in menus follow conventionally established nuclear medicine procedures, providing step-by-step guidance throughout defined procedures. The system automatically performs calculations, stores patient information and test results, and outputs clear, concise reports. User-defined uptake protocols can be initiated.
SCOPE
- Delivery of the Thyroid Uptake system will allow a bioassay program for quick and efficient measurement of the staff thyroid burden for radiopharmaceuticals, I-123, I-125 and I-131. Measurement results can be reported in cpm, dpm, uCi, or Bq. Action levels may be set by the user for each isotope. System reporting facilitates single bioassay report, summary of multiple bioassays on an individual staff member, and summary report on multiple staff members. Reports are easily printed or saved as PDF files.
- The Thyroid Uptake program supports multiple time-stamped uptake measurements, auto decay correction, user-defined uptake protocols, on-screen spectrum acquisition and analysis. The system provides reports that include normal ranges and allow notes/comments entered by the facility physician and technologists.
- The wipe test application automatically calculates net contamination levels and reports results in dpm, uCi and Bq. The program allows compliance with regulations for counting and reporting results of wipes taken for contamination surveys. The system allows user to define an unlimited number of “Area” names and wipe “Locations” entered within the areas for testing and documentation. Each area may be designated as “restricted”, “unrestricted”, “package” or “sealed source”. The user may specify count times, activity units, wide window, and individual isotopes and geometric efficiencies or simply utilize the wide range of factory default options.
- The program displays and stores the full spectrum with each wipe, automatically calculates net contamination levels and reports results in dpm, uCi or Bq. Wipes above the user defined trigger levels are easily identified. A detailed spectrum analysis may also be performed for any wipe to help identify isotopes causing contamination. Customized reports can be printed or saved in PDF format.
- The application specialist will provide training and guidance to ensure safe use of the equipment and the study and administration applications provided. The contractor will provide cybersecurity best practices information and training, when applicable.
- The contractor will provide application update to ensure information security in the current equipment and other factors that interconnects with the imaging system including the network, other current peripheral applications and other new tools and software that will be developed or installed to work with the current work station and imaging equipment hardware and software.
REQUIREMENT/SALIENT CHARACTERISTICS/SPECIFICATIONS
Common Nomenclature: MEDICAL SPECTROMETER HARDWARE
Kind of material: ALL IN ONE Touch Screen Computer
Electrical Data:
Power: Low voltage transformer with hospital grade power cord and plug.
Line Voltage:
120 VAC, 60 Hz, 2 AMP circuit breaker
230 VAC, 50 Hz, 1 AMP circuit breaker
Dimensions, size, capacity:
Minimum articulating arm with a minimum of 34 inch vertical range of travel with a minimum of 220 degree collimator rotation.
Principles of operation:
Multi-Channel Analyzer:
Channels: 1024
Spectral Resolution: FWHM 8%
Count Rate: (Maximum) 150,000 cps for Tc-99m
Count Rate Stability: 99%
Gross Count Rate Linearity: Within 5% up to 150,000 cps
Pulse Height Linearity: Within 2% (independent of detector)
Detector High Voltage Adjustment: Automatic adjustment for both probe and well; uses 10 μCi Cs-137 as the calibration source.
Restrictive environmental conditions: User Set: Unlimited user defined Isotopes, setting ROI, half life, name, efficiency and range.
Intended use:
Factory Programmed: Au-198, Ba-133, Co-57, Co-58, Co-60, Cr-51, Cs-137, F-18, Fe-59, Ga-67, Ga-68, Gd-153, Ge-68/Ga-68, Hg-197, I-123, I-125, I-131, In-111, Ir-192, K-42, Lu-177, Na-22, Na-24, Pd-103, Ra-223, Se-75, Sr-85, Tc-99m, Tc-99m/Tl-201, Tl-201, Yb-169, Wide Window.
Equipment with which the item is used, Job related tools:
Probe: 2" x 2" Nal (Tl) integral line scintillation detector
Other pertinent information that describes the item, material or service required:
Uptake Stand:
Dimensions:
Arm down and retracted: 34" l x 26" w x 55" h (86.4 x 66 x 139.7 cm)
Maximum Height: 60" (152.4 cm)
Maximum Length: Arm Extended: 61" (154.9 cm)
Collimated Shield: Flat field collimator meeting IAEA specifications
Positioning: Distance bar and positioning light
Casters: 4" Total locking
Maximum weigh of 300 lbs.
A maximum combined weight with Well Counter: 350 lbs.
Power: Low voltage transformer with hospital grade power cord and plug.
Line Voltage:
120 VAC, 60 Hz, 2 AMP circuit breaker
230 VAC, 50 Hz, 1 AMP circuit breaker
OTHER UNIQUE REQUIREMENTS : Minimum of 2 inch well container
Compatibility with Existing Equipment: TRM Compliance with VA Directives
WINDOWS 10 compatible or Newest Windows Version compliance with VHA standards.
Must be DICOM compliance, Directives or IT Policies, Required.
Coordination with On-going Construction Project (provide the project number): N/A
Warranty: 1 year from date of receipt and verification of installation/operation. Two years part/labor warranty
Training: Initial installation and launch training staff and service support
Service and/or Maintenance: Preventive maintenance and training support, to include two Operating Manuals and two Service Manuals
Safety/ISO/IT/BioMed/SPS & Other Departmental Compliance: Must meet Technical Reference Model (TRM) VA/BioMed Compliance.
DELIVERY
- Contractor must deliver all components of the system as stated in this solicitation within 30 days of award notice.
Standard FOB Destination to: John J. Pershing VA Medical Center, 1500 North Westwood Blvd, Poplar Bluff MO 63901.
Government-Furnished Property, Material, Equipment, or Information (GFP, GFM, GFE, or GFI) N/A
SECURITY N/A
SPECIAL MATERIAL REQUIREMENT two Operator’s Manuals and 2 Service Manuals
PLACE OF PERFORMANCE
The system will be installed, serviced, and updated at the facility, John J. Pershing VAMC, Poplar Bluff, MO, Nuclear Medicine Department. Servicing, training, and support of personnel will be per stipulations on the final contract.
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- 36C25525Q0265.pdf183 KB, March 14, 2025
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
March 14, 2025
Sources sought
Due March 20, 2025 at 12:00 PM EDT. SAM.gov, notice bb71221c18964a2dbd4c9e8ac64d7c50
2 revisions on SAM
- May 9, 2025: publish, solicitation
- March 14, 2025: publish, sources sought
Points of contact
- Tywanna Sparkstywanna.sparks@va.gov9137589928