# CARTO 3 - Cardio Mapping System

Canonical: https://sealedbidder.com/opportunities/36c25525q0204

- Solicitation number: 36C25525Q0204
- Notice type: Sources sought
- Status: Closed. Deadline was February 18, 2025 at 12:00 PM EST
- Department: Department of Veterans Affairs
- Contracting office: 255-Network Contract Office 15 (36C255)
- NAICS: 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing
- Product or service code: 6515 Medical and Surgical Instruments, Equipment, and Supplies
- Small business size standard: 1,250 employees (13 CFR 121.201, NAICS 334510)
- Place of performance: Missouri
- Who can bid, by location: Anywhere in the US. Location does not limit who can bid: a product shipped to the buyer, research at the performer's facility, or work at the contractor's site. A state shown is the delivery point.
- County: City of St. Louis (FIPS 29510). https://sealedbidder.com/counties/city-of-st-louis-mo-29510
- First posted: February 18, 2025
- Last posted: February 18, 2025
- SAM.gov: https://sam.gov/workspace/contract/opp/cbbe513fa61346b6ac2653a7aa94f688/view

## Reading this notice

- Kind of notice: Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it.
- Who may compete: SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 334510 (electromedical and electrotherapeutic apparatus manufacturing), means no more than 1,250 employees, counted with affiliates.
- What comes next: No solicitation was published under this number after the sources sought of February 18, 2025. An agency sometimes issues the solicitation under a new number.

## Description

Objective

The VA Saint Louis Health Care System has an urgent need for a new Biosense Webster CARTO 3 + Ultrasound System. This purchase will allow STLVAHCS to continue performing ablations to treat patients with Afib/Aflutter.

Equipment Specifications

Base Hardware

	CARTO PRIME Module Kit (KT5400322FG)

	CARTO SMARTTOUCH 3D Module Bundle (C3ST3D)

Additional Modules/Stand-Alone Modules

	CARTO 3 System Version 7.5 Base SW Upgrade Kit (Upgrading from V7.1 to V7.5) (KT5400505US

	CARTO 3 System Version 8 Upgrade Kit (Upgrading from V7.5 to V8 Service Packs) (KT5400600ESA)

	VISITAGSURPOINr" Module [VSPEPU2)

	PASO  Module [C3PASO]

	Ripple Mapping Module [KT5400170)

	FAM Ox Expansion Pack~ Module [KTS400165)

	CartoSEG CT Module [KT5400160]

	LAM Module [KT5400550US]

Additional Hardware

	Signal Processing Unit [SPU) [KT507000)

	nGEN System Superkit [NGENSYS]

	Ablation Cart [MA5402330]

Service

	ACCELERATED SOLUTIONS AGREEMENT (ASA) Package (ASASERVICE25)

	Service Features (ASAUP25)

Installation and Assembly

	Vendor shall be responsible for assembly and installation of systems after notification from VA Saint Louis Biomedical Engineering that it has been delivered to station.

	Installation shall include implementation and testing of all purchased interfaces to VA electronic systems in coordination with Clinical Staff, Biomedical Engineering staff, O&IT staff, and others identified as needed.

	Install shall include unboxing and transportation of equipment to final use location.

	Assembly and install shall occur within 30 days of delivery to station.

	Vendor shall provide all necessary accessories, cables, adaptors, etc. to deliver a fully functional clinical device.

Hours of Operation

	Normal hours of coverage are Monday through Friday, 7:00 AM to 3:30 PM Central Standard Time excluding national holidays.

	Vendor on-site visits will be coordinated with the VA Saint Louis Biomedical Engineering POC before being scheduled or conducted.

	Vendor representatives will check in with the VA Saint Louis Biomedical Engineering POC when they arrive on-site and check out upon completion of work each day.

	All services shall be performed during normal hours unless otherwise scheduled with the VA Saint Louis Biomedical Engineering POC.

	Vendor staff shall always be professional and shall take all necessary precautions to maintain a safe environment for the occupants. This includes, as necessary, coordinating access and closures for sensitive areas of the Medical Center.

	Vendor shall be responsible for cleaning all work areas after completion of tasks. This includes removal of packaging and a clean sweep/mop of the area as required by work type.

	Vendor staff shall minimize noise as much as possible while working in all buildings.

	Vendor is responsible for providing all PPE necessary for their work.

Note:  Hardware/software update/upgrade installations, where applicable, may be scheduled and performed outside normal hours of coverage at no additional charge to the Government (unless it would be detrimental to equipment up-time; to be determined by the VA Saint Louis Biomedical Engineering POC).

Federal Holidays observed by VA Saint Louis are:

Delivery

	Vendor shall deliver purchased equipment within 60 business days of receiving completed Contracting package from the VISN 15 Contracting Officer. If delivery delays occur vendor shall notify the Contracting Officer and the VA Saint Louis Biomedical Engineering POC.

	Delivery will be to one of the two VA Saint Louis Health Care System main campuses. Vendor shall coordinate exact delivery location with the Contracting Officer and VA Saint Louis Biomedical Engineering POC at the time of the purchase.

	Vendor will ensure that equipment is sent to the Attention of Biomedical Engineering and will include the VA Saint Louis PO Number on the shipping label.

	Delivery of oversized, palletized orders or orders that contain a large number of components will be coordinated with VA Saint Louis Biomedical Engineering POC who will communicate internally with Warehouse Staff.

John Cochran

915 North Grand Blvd

Saint Louis, MO 63106

ATTN: Equipment Committee

PO Number for Order

Biosense Webster CARTO&reg; 3 and GENERATOR System Maintenance

SCOPE:

This Purchase Order shall be for a one (1) year base with two (2) one-year options to extend. The Accelerated Solutions Agreement (ASA) Purchase Order shall provide preventive maintenance service on the CARTO&reg; 3 and Generator systems at ST LOUIS VA MEDICAL CENTER. Additionally, it provides corrective maintenance on the system if it shall be malfunctioning or inoperable at a mutually agreeable time and loaner equipment, when deemed necessary by the Contractor. Training materials shall be provided for base software upgrades that affect user operation of the base software. The ASA shall also provide New Equipment /or New Software.

Equipment to be covered by this agreement:

CARTO&reg; 3 System Serial Nbr: 13449

Generator System Serial Nbr: G4C-2491

Generator Pump Serial Nbr: G4CP-2506

Generator Remote Serial Nbr: G4RC-2529

## Attachments

- [36C25525Q0204.pdf](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/56a106f7e387494e9754ce7d2212b74d/download)
- [Updated 121024 CARTO 3 SOW.docx](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/2e3825bf2590404d9f28a28739afd0b5/download)

## Open now in the same industry

11 open in NAICS 334510.

- NCSS - Sentec tCOM+ Transcutaneous CO2 Monitor Acq (75N98027Q00094), due November 27, 2026 at 11:00 AM EST. https://sealedbidder.com/opportunities/75n98027q00094
- Medtronic FT10 Series Cauterizer (36C26327Q0131), due November 30, 2026 at 11:00 AM EST. https://sealedbidder.com/opportunities/36c26327q0131
- FY27 Mobile CT Scanner Lease (36C24827Q0085), due November 30, 2026 at 4:00 PM EST. https://sealedbidder.com/opportunities/36c24827q0085

## Publications

- February 18, 2025: Sources sought, due February 18, 2025 at 12:00 PM EST. Notice cbbe513fa61346b6ac2653a7aa94f688. https://sam.gov/workspace/contract/opp/cbbe513fa61346b6ac2653a7aa94f688/view

## Points of contact

- Jon Lutmer, Jonathan.lutmer@va.gov, 4104463862

---
Source: SAM.gov Contract Opportunities bulk extract. Confirm deadlines on SAM.gov before responding. Cite https://sealedbidder.com/opportunities/36c25525q0204.