{"canonical":"https://sealedbidder.com/opportunities/36c25227q0080","key":"36C25227Q0080","url":"https://sealedbidder.com/opportunities/36c25227q0080","title":"H399--Elevator Inspection Service FHCC VAMC in North Chicago IL Base 4 OY","solicitation_number":"36C25227Q0080","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-11-11T16:00:00Z","first_posted":"2026-11-03","last_posted":"2026-11-03","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"541350","psc":"H399","set_aside":null,"place_state":"IL","place_scope":"site","site":null,"place_state_source":"description","place_evidence":"R ( FHCC ), 3001 GREEN BAY ROAD, NORTH CHICAGO, IL 60064-3048","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"948514bd6b9f4600991059064d96d001","title":"H399--Elevator Inspection Service FHCC VAMC in North Chicago IL Base 4 OY","solicitation_number":"36C25227Q0080","notice_type":"r","base_type":"r","posted":"2026-11-03","posted_at":"2026-11-03T14:53:08.260Z","due_at":"2026-11-11T16:00:00Z","due_date":"2026-11-11","cancelled":false,"archived":false,"archive_date":"2026-12-11","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/948514bd6b9f4600991059064d96d001/view","enriched":true,"history":[{"index":1,"title":"H399--Elevator Inspection Service FHCC VAMC in North Chicago IL Base 4 OY","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-03T14:53:08.260Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"948514bd6b9f4600991059064d96d001","solicitation_number":"36C25227Q0080"}]}],"latest_notice_id":"948514bd6b9f4600991059064d96d001","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-11-03","posted_at":"2026-11-03T14:53:08.260Z","created_at":"2026-11-03T14:53:06.070Z","modified_at":"2026-11-03T14:53:08.260Z","response_deadline":{"raw":"2026-11-11T10:00:00-06:00","utc":"2026-11-11T16:00:00Z","date":"2026-11-11","time":"10:00:00","timezone":"America/Chicago","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/948514bd6b9f4600991059064d96d001/view"},"naics":{"codes":["541350"],"primary":"541350"},"title":"H399--Elevator Inspection Service FHCC VAMC in North Chicago IL Base 4 OY","agency":{"office":{"code":"36C252","name":"252-NETWORK CONTRACT OFFICE 12 (36C252)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"53214","city":"MILWAUKEE","state":"WI","country":"USA"},"organization_id":"100180018","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-12-11","archive_type":"auto_custom"},"history":[{"index":1,"title":"H399--Elevator Inspection Service FHCC VAMC in North Chicago IL Base 4 OY","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-03T14:53:08.260Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"948514bd6b9f4600991059064d96d001","solicitation_number":"36C25227Q0080"}],"contacts":[{"name":"Michelle R Klug","role":"primary","email":"michelle.klug2@va.gov","phone":"224-610-3248","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"948514bd6b9f4600991059064d96d001","lineage_id":"948514bd6b9f4600991059064d96d001","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-11T10:32:25.543511534Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"344d34c55b408d36a8af20c5de2dcd6dd1a566911dc39aa87d982e9b80fef79a","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-11T10:32:25.543511534Z","first_seen_at":"2026-11-04T05:10:28.855326963Z"},"description":{"html":"SOURCES SOUGHT SYNOPSIS \nThe Department of Veterans Affairs is issuing this sources sought synopsis as a means of conducting market research to identify parties having an interest in and the resources to support a requirement for Elevator Testing  Services located at FHCC VAMC , North Chicago IL.\n\no Captain James A. Lovell Federal Health Care Center, North Chicago, IL. \n\n\nThe result of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 341350.\nTHERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred. \nBackground: \n\nThe purpose of this Contract is to provide for the inspection/testing of the vertical transportation system located at the Captain James A. Lovell Federal Health Care Center ( FHCC ), 3001 Green Bay Road, North Chicago, IL 60064-3048, as set forth in this Performance Work Statement.  A complete listing of all vertical transportation system components, including thirty-one (31) elevators, two (2) cart lifts, and two (2) dumbwaiters (collectively  VTS components ), is set forth in the Vertical Transportation System Schedule at the end of this Performance Work Statement. Any additional vertical transportation system components put into service after award of this Contract shall be included in the Vertical Transportation System Schedule at price(s) consistent with the current Price Schedule.\nA complete listing of all VTS Components, including twenty-nine (31) elevators, two (2) cart lifts, and two (2) dumbwaiters, is set forth in the Vertical Transportation System Schedule at the end of this Statement of Work. Any additional vertical transportation system components put into service after award of this Contract shall be included in the Vertical Transportation System Inventory at price(s) consistent with the current Price Schedule. \n\nIf your organization has the potential capacity to perform these contract services, please provide the following information: 1) Organization name, address, email address, website address, if applicable, telephone number, and size and type of ownership for the organization; and 2) Tailored capability statements addressing the particulars of this effort and documentation supporting claims of organizational and staff capability. If significant subcontracting or teaming is anticipated in order to deliver technical capability, organizations should address the administrative and management structure of such arrangements. \nThe Government will evaluate market information to ascertain potential market capacity to provide services consistent in scope and scale with those described in this notice and otherwise anticipated. \nBASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SDVOSB.  Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions.  \n\nSubmission Instructions: Interested parties who consider themselves qualified to perform the above-listed services are invited to submit a response to this Sources Sought Notice by 10:00AM Local Time (Central) on November 11th, 2026. All responses under this Sources Sought Notice shall be emailed to Michelle.Klug2@va.gov.\n\n\n\nSTATEMENT OF WORK\nInspections Overview: The Contractor shall perform Annual Category 1, Semiannual, and Full-Load Category 5 VTS component inspection/testing as follows: a. Annual Category 1 inspection/testing is typically conducted in May of each year; \na. Semiannual inspection/testing is typically conducted in November of each year; and \nb. Full-Load Category 5 testing will be performed in November 2027. \nc. Note: Typical inspection/testing dates are subject to change, in FHCC s sole discretion. \nBasic Contractor Responsibilities: The Contractor shall provide all personnel, equipment, material, parts, software, supplies, facilities, transportation, tools, materials, supervision, and other items and non-personal services necessary for execution of the work to be performed under this Contract. Any work found to be non-conforming to the terms of this Contract shall be promptly corrected by the Contractor at no additional cost to the Government. All work shall be performed in a neat and professional manner, including the removal of all trash and debris at the completion of all work. \nContractor Limitations: The Contractor performing inspection/testing under this Contract is prohibited from performing any repairs or other work on any of the VTS components covered by this Contract. \nSafety: All work performed under this Contract shall conform to such safety precautions as the FHCC Fire/Safety and Engineering Departments determine, in their sole discretion, to be necessary, in addition to all other requirements set forth elsewhere in the Contract. \nInspection/Testing Standards. \n1. All inspection/testing of FHCC s vertical transportation system components shall comply with the most current version of the following standards: \n\na. American Society of Mechanical Engineers ( ASME ) 17.1: Handbook on Safety Code for Elevators and Escalators; \nb. ASME 17.2: Guide for Inspection of Elevators, Escalators, and Moving Walks; \nc. ASME 17.3: Safety Code for Existing Elevators and Escalators; \nd. National Fire Protection Association ( NFPA ) 70: National Electrical Code; and \ne. NFPA 70E: Standard for Electrical Safety in the Workplace. \n2. During any inspection/testing, parts shall be removed and equipment cleaned, as necessary, to determine their exact condition. All parts shall be properly reinstalled after removal. \n3. All inspections shall be performed in the presence of an elevator maintenance technician, currently under contract as the VA elevator maintenance contractor, and the COR or designated FHCC representative. \n4. Immediately following the conclusion of each inspection/testing, the Contractor shall brief the COR or designated FHCC representative regarding the inspection/testing results, including without limitation: code violations, safety concerns, and immediate maintenance needs. \n5. The COR, in the COR s sole discretion, may reject any work performed under this Contract that is noncompliant with any of the requirements set forth in this Contract. All rejected work shall be corrected as quickly as reasonably possible at no additional expense to the Government. \nInspection Checklists: The Contractor shall provide a fully completed inspection checklist applicable to each VTS component using the Checklist for Inspection of Electric Elevators The comments section of each checklist shall include a. If the VTS component is safe operating condition; \na. If the VTS component will perform in accordance with Original Equipment Manufacturer ( OEM ) standards; \nb. Whether the VTS component has been altered, except in conformity with all applicable standards set forth in this Contract; \nc. If the VTS component has any deficiencies, referencing the appropriate standard as applicable; and \nd. Whether there are any recommended VTS component repairs or upgrades. \ne. Documentation. Upon completion of the inspection/testing of all FHCC s VTS components, the Contractor shall provide a report within thirty (30) days to the COR and other FHCC personnel as directed. The report shall be electronically submitted in pdf format utilizing word processing to the maximum extent practicable; individual file size shall not exceed 7 MB. Each report should include: \n\n\nCertificates of Inspection: The Certificate of Inspection for each VTS component shall include the following information: a. Location (building and city/state); \na. Identification number; \nb. Capacity; \nc. Speed; \nd. Date of inspection; \ne. Name of inspector and company; \nf. Inspector s signature; and \ng. Inspector s Qualified Elevator Inspector ( QEI ) number. \nScheduling Inspection/Testing: The Contractor shall coordinate a mutually agreeable time with the COR at least thirty (30) days prior to the typical inspection months, as defined above. \n Hours for Inspection/Testing: All work performed under this Contract shall be performed during normal hours of facility operation, as defined below, except for inspection/testing that, in the COR s judgment, may severely impact elevator service. Inspection/testing that severely impacts elevator service shall be conducted after normal hours of facility operation at no additional cost to the Government. \nReinspection: If any VTS component(s) require reinspection, the Contractor shall: a. Provide a quote to the COR for the reinspection(s) at a price consistent with the Price Schedule s Unit Price for the current contract period; and \na. Coordinate reinspection(s) with the COR only after a Contract Modification has been awarded authorizing such reinspection. \nb. Inspector Qualifications. Inspectors performing VTS component inspection/testing under this Contract shall be a currently certified Qualified Elevator Inspector by an ASME-accredited organization, in accordance with ASME QEI-1: Standard for the Qualification of Elevator Inspectors. Inspectors performing work under this Contract shall be regularly employed by the Contractor. The Contractor shall provide a copy of each inspector s QEI-1 certification to the COR prior to any VTS component inspection/testing being performed. \nc. Scheduling. \nd. On-Site Work Requirements. In addition to any other requirements set forth in this Contract, the Contractor shall comply with the following on-site work requirements:\n\nContractor Orientation/Training: The Contractor shall attend an orientation prior to beginning any work under this Contract, at the COR s discretion. This orientation may include the following topics: Contract terms and conditions; performance monitoring; badging procedures; safety; fire procedures; severe weather procedures; disease transmission; infection control; disaster procedures; and any other topic deemed necessary by the COR. At the COR s discretion, the Contractor may be responsible for providing some or all this information/training to its employees, as directed by the COR. \nCheck-in/Check-out Requirements: The Contractor shall comply with all facility check-in and screening requirements. Upon successful completion of the facility s check-in and screening process, the Contractor shall check-in with the COR, or the COR s designee, advising them of the nature and location of the work to be accomplished. The Contractor shall check-out with the COR, or the COR s designee, at the conclusion of such work, prior to departing the VA facility, advising them of the work completed and any problems/issues identified. \nHours of Operation: Normal hours of facility operation ( Business Hours ) are Monday through Friday, 7:00 a.m.   3:30 p.m. Local Time, except for the following Federal Holidays:\n \na. New Year s Day; \na. Birthday of Martin Luther King, Jr.; \nb. Washington s Birthday; \nc. Memorial Day; \nd. Juneteenth National Independence Day; \ne. Independence Day; \nf. Labor Day; \ng. Columbus Day; \nh. Veterans Day; \ni. Thanksgiving Day; \nj. Christmas Day; \n**** Any other day declared a Federal Holiday by Presidential Proclamation**** \n\nNoninterference with Facility Functions: The Contractor shall perform its services under this Contract in a manner that does not interfere with the facility s functions, including maintaining all tools and equipment in an orderly fashion and cleaning the work area at the conclusion of a service visit. The Contractor shall interrupt its work at any time to not interfere with the normal functioning of the facility, including utility services, fire protection systems, and passage of facility patients, personnel, equipment, and carts. In the event of an emergency, Contractor \n\n\n\nMANUFACTURER\nTYPE\nELEVATOR #\nLOCATION\nInspection Frequency\n1\nSMARTRISE/HW\nTRACTION\nP-1\nBLDG. 133 CA\nAnnual May/Semi-Annual November\n2\nSMARTRISE/HW\nTRACTION\nP-2\nBLDG. 133 CA\nAnnual May/Semi-Annual November\n3\nSMARTRISE/HW\nTRACTION\nP-3\nBLDG. 133 CA\nAnnual May/Semi-Annual November\n4\nMID-AMERICAN\nTRACTION\nP-4\nBLDG. 131\nAnnual May/Semi-Annual November\n5\nMID-AMERICAN\nTRACTION\nP-5\nBLDG. 131\nAnnual May/Semi-Annual November\n6\nSMARTRISE/HW\nTRACTION\nP-7\nBLDG. 133\nAnnual May/Semi-Annual November\n7\nSMARTRISE/HW\nTRACTION\nP-8\nBLDG. 133\nAnnual May/Semi-Annual November\n8\nSMARTRISE\nTRACTION\nP-10\nBLDG. 134\nAnnual May/Semi-Annual November\n9\nSMARTRISE\nTRACTION\nP-11\nBLDG. 134\nAnnual May/Semi-Annual November\n10\nSMARTRISE\nTRACTION\nP-13\nBLDG. 135\nAnnual May/Semi-Annual November\n11\nSMARTRISE\nTRACTION\nP-18\nBLDG. 1\nAnnual May/Semi-Annual November\n12\nMID-AMERICAN\nHYDRAULIC\nP-20\nBLDG. 46\nAnnual May/Semi-Annual November\n13\nMID-AMERICAN\nTRACTION\nP-21\nBLDG. 66\nAnnual May/Semi-Annual November\n14\nMID-AMERICAN\nTRACTION\nP-22\nBLDG. 7\nAnnual May/Semi-Annual November\n15\nMID-AMERICAN\nHYDRAULIC\nP-23\nBLDG. 4\nAnnual May/Semi-Annual November\n16\nMID-AMERICAN\nHYDRAULIC\nP-24\nBLDG. 133\nAnnual May/Semi-Annual November\n17\nSCHUMACKER ELEVATOR\nHYDRAULIC\nP-25\nPARKING GARAGE 195\nAnnual May/Semi-Annual November\n18\nSCHUMACKER ELEVATOR\nHYDRAULIC\nP-26\nPARKING GARAGE\nAnnual May/Semi-Annual November\n19\nSCHUMACKER ELEVATOR\nHYDRAULIC\nP-1\nBLDG. 133EF\nAnnual May/Semi-Annual November\n\n20\nSCHUMACKER ELEVATOR\nHYDRAULIC\nP-2\nBLDG. 133EF\nAnnual May/Semi-Annual November\n21\nSMARTRISE\nHYDRAULIC\nS-1\nBLDG. 133CA\nAnnual May/Semi-Annual November\n22\nSCHUMACKER ELEVATOR\nHYDRAULIC\nS-1\nBLDG. 133EF\nAnnual May/Semi-Annual November\n23\nSCHINDLER\nHYDRAULIC\nS-2\nBLDG. 6\nAnnual May/Semi-Annual November\n24\nSCHINDLER\nHYDRAULIC\nS-3\nBLDG. 6\nAnnual May/Semi-Annual November\n25\nMID-AMERICAN\nTRACTION\nS-6\nBLDG. 131\nAnnual May/Semi-Annual November\n26\nSMARTRISE\nTRACTION\nS-9\nBLDG. 133\nAnnual May/Semi-Annual November\n27\nSMARTRISE\nTRACTION\nS-12\nBLDG. 134\nAnnual May/Semi-Annual November\n28\nSMARTRISE\nTRACTION\nSF-14\nBLDG. 135\nAnnual May/Semi-Annual November\n29\nKONE\nTRACTION\nP-27\nPARKING GARAGE 196\nAnnual May/Semi-Annual November\n30\nTAC32H\nHYDRAULIC\n556FH-ELEV-001-CO100\nCORRIDOR 100\nAnnual May/Semi-Annual November\n31\nSMARTRISE\nHYDRAULIC\n5-ELEV-E1-CO101\nCORRIDOR 101\nAnnual May/Semi-Annual November\nFHCC VERTICAL TRANSPORTATION SYSTEM SCHEDULE ELEVATORS\n\n\n\n\nCART LIFTS\n\nMANUFACTURER\nCART LIFT #\nLOCATION\nINSPECTION FREQUENCY\n1\nLIFT-O-MATIC\nCART LIFT 1\nBLDG. 133CA\nAnnual May/Semi-Annual November\n2\nLIFT-O-MATIC\nCART LIFT 2\nBLDG. 133CA\nAnnual May/Semi-Annual November\n\nDUMBWATIERS\n\nDUMBWAITER #\nLOCATION\nINSPECTION FREQUENCY\n1\nDUMBWAITER 1\nBLDG. 133\nAnnual May/Semi-Annual November\n2\nDUMBWAITER 2\nBLDG. 133CA\nAnnual May/Semi-Annual November","text":"SOURCES SOUGHT SYNOPSIS\nThe Department of Veterans Affairs is issuing this sources sought synopsis as a means of conducting market research to identify parties having an interest in and the resources to support a requirement for Elevator Testing Services located at FHCC VAMC , North Chicago IL.\n\no Captain James A. Lovell Federal Health Care Center, North Chicago, IL.\n\nThe result of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 341350.\nTHERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred.\nBackground:\n\nThe purpose of this Contract is to provide for the inspection/testing of the vertical transportation system located at the Captain James A. Lovell Federal Health Care Center ( FHCC ), 3001 Green Bay Road, North Chicago, IL 60064-3048, as set forth in this Performance Work Statement. A complete listing of all vertical transportation system components, including thirty-one (31) elevators, two (2) cart lifts, and two (2) dumbwaiters (collectively VTS components ), is set forth in the Vertical Transportation System Schedule at the end of this Performance Work Statement. Any additional vertical transportation system components put into service after award of this Contract shall be included in the Vertical Transportation System Schedule at price(s) consistent with the current Price Schedule.\nA complete listing of all VTS Components, including twenty-nine (31) elevators, two (2) cart lifts, and two (2) dumbwaiters, is set forth in the Vertical Transportation System Schedule at the end of this Statement of Work. Any additional vertical transportation system components put into service after award of this Contract shall be included in the Vertical Transportation System Inventory at price(s) consistent with the current Price Schedule.\n\nIf your organization has the potential capacity to perform these contract services, please provide the following information: 1) Organization name, address, email address, website address, if applicable, telephone number, and size and type of ownership for the organization; and 2) Tailored capability statements addressing the particulars of this effort and documentation supporting claims of organizational and staff capability. If significant subcontracting or teaming is anticipated in order to deliver technical capability, organizations should address the administrative and management structure of such arrangements.\nThe Government will evaluate market information to ascertain potential market capacity to provide services consistent in scope and scale with those described in this notice and otherwise anticipated.\nBASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SDVOSB. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions.\n\nSubmission Instructions: Interested parties who consider themselves qualified to perform the above-listed services are invited to submit a response to this Sources Sought Notice by 10:00AM Local Time (Central) on November 11th, 2026. All responses under this Sources Sought Notice shall be emailed to Michelle.Klug2@va.gov.\n\nSTATEMENT OF WORK\nInspections Overview: The Contractor shall perform Annual Category 1, Semiannual, and Full-Load Category 5 VTS component inspection/testing as follows: a. Annual Category 1 inspection/testing is typically conducted in May of each year;\na. Semiannual inspection/testing is typically conducted in November of each year; and\nb. Full-Load Category 5 testing will be performed in November 2027.\nc. Note: Typical inspection/testing dates are subject to change, in FHCC s sole discretion.\nBasic Contractor Responsibilities: The Contractor shall provide all personnel, equipment, material, parts, software, supplies, facilities, transportation, tools, materials, supervision, and other items and non-personal services necessary for execution of the work to be performed under this Contract. Any work found to be non-conforming to the terms of this Contract shall be promptly corrected by the Contractor at no additional cost to the Government. All work shall be performed in a neat and professional manner, including the removal of all trash and debris at the completion of all work.\nContractor Limitations: The Contractor performing inspection/testing under this Contract is prohibited from performing any repairs or other work on any of the VTS components covered by this Contract.\nSafety: All work performed under this Contract shall conform to such safety precautions as the FHCC Fire/Safety and Engineering Departments determine, in their sole discretion, to be necessary, in addition to all other requirements set forth elsewhere in the Contract.\nInspection/Testing Standards.\n1. All inspection/testing of FHCC s vertical transportation system components shall comply with the most current version of the following standards:\n\na. American Society of Mechanical Engineers ( ASME ) 17.1: Handbook on Safety Code for Elevators and Escalators;\nb. ASME 17.2: Guide for Inspection of Elevators, Escalators, and Moving Walks;\nc. ASME 17.3: Safety Code for Existing Elevators and Escalators;\nd. National Fire Protection Association ( NFPA ) 70: National Electrical Code; and\ne. NFPA 70E: Standard for Electrical Safety in the Workplace.\n2. During any inspection/testing, parts shall be removed and equipment cleaned, as necessary, to determine their exact condition. All parts shall be properly reinstalled after removal.\n3. All inspections shall be performed in the presence of an elevator maintenance technician, currently under contract as the VA elevator maintenance contractor, and the COR or designated FHCC representative.\n4. Immediately following the conclusion of each inspection/testing, the Contractor shall brief the COR or designated FHCC representative regarding the inspection/testing results, including without limitation: code violations, safety concerns, and immediate maintenance needs.\n5. The COR, in the COR s sole discretion, may reject any work performed under this Contract that is noncompliant with any of the requirements set forth in this Contract. All rejected work shall be corrected as quickly as reasonably possible at no additional expense to the Government.\nInspection Checklists: The Contractor shall provide a fully completed inspection checklist applicable to each VTS component using the Checklist for Inspection of Electric Elevators The comments section of each checklist shall include a. If the VTS component is safe operating condition;\na. If the VTS component will perform in accordance with Original Equipment Manufacturer ( OEM ) standards;\nb. Whether the VTS component has been altered, except in conformity with all applicable standards set forth in this Contract;\nc. If the VTS component has any deficiencies, referencing the appropriate standard as applicable; and\nd. Whether there are any recommended VTS component repairs or upgrades.\ne. Documentation. Upon completion of the inspection/testing of all FHCC s VTS components, the Contractor shall provide a report within thirty (30) days to the COR and other FHCC personnel as directed. The report shall be electronically submitted in pdf format utilizing word processing to the maximum extent practicable; individual file size shall not exceed 7 MB. Each report should include:\n\nCertificates of Inspection: The Certificate of Inspection for each VTS component shall include the following information: a. Location (building and city/state);\na. Identification number;\nb. Capacity;\nc. Speed;\nd. Date of inspection;\ne. Name of inspector and company;\nf. Inspector s signature; and\ng. Inspector s Qualified Elevator Inspector ( QEI ) number.\nScheduling Inspection/Testing: The Contractor shall coordinate a mutually agreeable time with the COR at least thirty (30) days prior to the typical inspection months, as defined above.\nHours for Inspection/Testing: All work performed under this Contract shall be performed during normal hours of facility operation, as defined below, except for inspection/testing that, in the COR s judgment, may severely impact elevator service. Inspection/testing that severely impacts elevator service shall be conducted after normal hours of facility operation at no additional cost to the Government.\nReinspection: If any VTS component(s) require reinspection, the Contractor shall: a. Provide a quote to the COR for the reinspection(s) at a price consistent with the Price Schedule s Unit Price for the current contract period; and\na. Coordinate reinspection(s) with the COR only after a Contract Modification has been awarded authorizing such reinspection.\nb. Inspector Qualifications. Inspectors performing VTS component inspection/testing under this Contract shall be a currently certified Qualified Elevator Inspector by an ASME-accredited organization, in accordance with ASME QEI-1: Standard for the Qualification of Elevator Inspectors. Inspectors performing work under this Contract shall be regularly employed by the Contractor. The Contractor shall provide a copy of each inspector s QEI-1 certification to the COR prior to any VTS component inspection/testing being performed.\nc. Scheduling.\nd. On-Site Work Requirements. In addition to any other requirements set forth in this Contract, the Contractor shall comply with the following on-site work requirements:\n\nContractor Orientation/Training: The Contractor shall attend an orientation prior to beginning any work under this Contract, at the COR s discretion. This orientation may include the following topics: Contract terms and conditions; performance monitoring; badging procedures; safety; fire procedures; severe weather procedures; disease transmission; infection control; disaster procedures; and any other topic deemed necessary by the COR. At the COR s discretion, the Contractor may be responsible for providing some or all this information/training to its employees, as directed by the COR.\nCheck-in/Check-out Requirements: The Contractor shall comply with all facility check-in and screening requirements. Upon successful completion of the facility s check-in and screening process, the Contractor shall check-in with the COR, or the COR s designee, advising them of the nature and location of the work to be accomplished. The Contractor shall check-out with the COR, or the COR s designee, at the conclusion of such work, prior to departing the VA facility, advising them of the work completed and any problems/issues identified.\nHours of Operation: Normal hours of facility operation ( Business Hours ) are Monday through Friday, 7:00 a.m. 3:30 p.m. Local Time, except for the following Federal Holidays:\n\na. New Year s Day;\na. Birthday of Martin Luther King, Jr.;\nb. Washington s Birthday;\nc. Memorial Day;\nd. Juneteenth National Independence Day;\ne. Independence Day;\nf. Labor Day;\ng. Columbus Day;\nh. Veterans Day;\ni. Thanksgiving Day;\nj. Christmas Day;\n**** Any other day declared a Federal Holiday by Presidential Proclamation****\n\nNoninterference with Facility Functions: The Contractor shall perform its services under this Contract in a manner that does not interfere with the facility s functions, including maintaining all tools and equipment in an orderly fashion and cleaning the work area at the conclusion of a service visit. The Contractor shall interrupt its work at any time to not interfere with the normal functioning of the facility, including utility services, fire protection systems, and passage of facility patients, personnel, equipment, and carts. In the event of an emergency, Contractor\n\nMANUFACTURER\nTYPE\nELEVATOR #\nLOCATION\nInspection Frequency\n1\nSMARTRISE/HW\nTRACTION\nP-1\nBLDG. 133 CA\nAnnual May/Semi-Annual November\n2\nSMARTRISE/HW\nTRACTION\nP-2\nBLDG. 133 CA\nAnnual May/Semi-Annual November\n3\nSMARTRISE/HW\nTRACTION\nP-3\nBLDG. 133 CA\nAnnual May/Semi-Annual November\n4\nMID-AMERICAN\nTRACTION\nP-4\nBLDG. 131\nAnnual May/Semi-Annual November\n5\nMID-AMERICAN\nTRACTION\nP-5\nBLDG. 131\nAnnual May/Semi-Annual November\n6\nSMARTRISE/HW\nTRACTION\nP-7\nBLDG. 133\nAnnual May/Semi-Annual November\n7\nSMARTRISE/HW\nTRACTION\nP-8\nBLDG. 133\nAnnual May/Semi-Annual November\n8\nSMARTRISE\nTRACTION\nP-10\nBLDG. 134\nAnnual May/Semi-Annual November\n9\nSMARTRISE\nTRACTION\nP-11\nBLDG. 134\nAnnual May/Semi-Annual November\n10\nSMARTRISE\nTRACTION\nP-13\nBLDG. 135\nAnnual May/Semi-Annual November\n11\nSMARTRISE\nTRACTION\nP-18\nBLDG. 1\nAnnual May/Semi-Annual November\n12\nMID-AMERICAN\nHYDRAULIC\nP-20\nBLDG. 46\nAnnual May/Semi-Annual November\n13\nMID-AMERICAN\nTRACTION\nP-21\nBLDG. 66\nAnnual May/Semi-Annual November\n14\nMID-AMERICAN\nTRACTION\nP-22\nBLDG. 7\nAnnual May/Semi-Annual November\n15\nMID-AMERICAN\nHYDRAULIC\nP-23\nBLDG. 4\nAnnual May/Semi-Annual November\n16\nMID-AMERICAN\nHYDRAULIC\nP-24\nBLDG. 133\nAnnual May/Semi-Annual November\n17\nSCHUMACKER ELEVATOR\nHYDRAULIC\nP-25\nPARKING GARAGE 195\nAnnual May/Semi-Annual November\n18\nSCHUMACKER ELEVATOR\nHYDRAULIC\nP-26\nPARKING GARAGE\nAnnual May/Semi-Annual November\n19\nSCHUMACKER ELEVATOR\nHYDRAULIC\nP-1\nBLDG. 133EF\nAnnual May/Semi-Annual November\n\n20\nSCHUMACKER ELEVATOR\nHYDRAULIC\nP-2\nBLDG. 133EF\nAnnual May/Semi-Annual November\n21\nSMARTRISE\nHYDRAULIC\nS-1\nBLDG. 133CA\nAnnual May/Semi-Annual November\n22\nSCHUMACKER ELEVATOR\nHYDRAULIC\nS-1\nBLDG. 133EF\nAnnual May/Semi-Annual November\n23\nSCHINDLER\nHYDRAULIC\nS-2\nBLDG. 6\nAnnual May/Semi-Annual November\n24\nSCHINDLER\nHYDRAULIC\nS-3\nBLDG. 6\nAnnual May/Semi-Annual November\n25\nMID-AMERICAN\nTRACTION\nS-6\nBLDG. 131\nAnnual May/Semi-Annual November\n26\nSMARTRISE\nTRACTION\nS-9\nBLDG. 133\nAnnual May/Semi-Annual November\n27\nSMARTRISE\nTRACTION\nS-12\nBLDG. 134\nAnnual May/Semi-Annual November\n28\nSMARTRISE\nTRACTION\nSF-14\nBLDG. 135\nAnnual May/Semi-Annual November\n29\nKONE\nTRACTION\nP-27\nPARKING GARAGE 196\nAnnual May/Semi-Annual November\n30\nTAC32H\nHYDRAULIC\n556FH-ELEV-001-CO100\nCORRIDOR 100\nAnnual May/Semi-Annual November\n31\nSMARTRISE\nHYDRAULIC\n5-ELEV-E1-CO101\nCORRIDOR 101\nAnnual May/Semi-Annual November\nFHCC VERTICAL TRANSPORTATION SYSTEM SCHEDULE ELEVATORS\n\nCART LIFTS\n\nMANUFACTURER\nCART LIFT #\nLOCATION\nINSPECTION FREQUENCY\n1\nLIFT-O-MATIC\nCART LIFT 1\nBLDG. 133CA\nAnnual May/Semi-Annual November\n2\nLIFT-O-MATIC\nCART LIFT 2\nBLDG. 133CA\nAnnual May/Semi-Annual November\n\nDUMBWATIERS\n\nDUMBWAITER #\nLOCATION\nINSPECTION FREQUENCY\n1\nDUMBWAITER 1\nBLDG. 133\nAnnual May/Semi-Annual November\n2\nDUMBWAITER 2\nBLDG. 133CA\nAnnual May/Semi-Annual November","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25227Q0080","product_service_code":"H399"}],"due_at":"2026-11-11T16:00:00Z","due_date":"2026-11-11","closes_at":"2026-11-11T16:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","state":"IL","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":"description","state_evidence":"R ( FHCC ), 3001 GREEN BAY ROAD, NORTH CHICAGO, IL 60064-3048","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-11-04T05:14:00.353426Z","principal_notice_id":"948514bd6b9f4600991059064d96d001","description":{"text":"SOURCES SOUGHT SYNOPSIS\nThe Department of Veterans Affairs is issuing this sources sought synopsis as a means of conducting market research to identify parties having an interest in and the resources to support a requirement for Elevator Testing Services located at FHCC VAMC , North Chicago IL.\n\no Captain James A. Lovell Federal Health Care Center, North Chicago, IL.\n\nThe result of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 341350.\nTHERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred.\nBackground:\n\nThe purpose of this Contract is to provide for the inspection/testing of the vertical transportation system located at the Captain James A. Lovell Federal Health Care Center ( FHCC ), 3001 Green Bay Road, North Chicago, IL 60064-3048, as set forth in this Performance Work Statement. A complete listing of all vertical transportation system components, including thirty-one (31) elevators, two (2) cart lifts, and two (2) dumbwaiters (collectively VTS components ), is set forth in the Vertical Transportation System Schedule at the end of this Performance Work Statement. Any additional vertical transportation system components put into service after award of this Contract shall be included in the Vertical Transportation System Schedule at price(s) consistent with the current Price Schedule.\nA complete listing of all VTS Components, including twenty-nine (31) elevators, two (2) cart lifts, and two (2) dumbwaiters, is set forth in the Vertical Transportation System Schedule at the end of this Statement of Work. Any additional vertical transportation system components put into service after award of this Contract shall be included in the Vertical Transportation System Inventory at price(s) consistent with the current Price Schedule.\n\nIf your organization has the potential capacity to perform these contract services, please provide the following information: 1) Organization name, address, email address, website address, if applicable, telephone number, and size and type of ownership for the organization; and 2) Tailored capability statements addressing the particulars of this effort and documentation supporting claims of organizational and staff capability. If significant subcontracting or teaming is anticipated in order to deliver technical capability, organizations should address the administrative and management structure of such arrangements.\nThe Government will evaluate market information to ascertain potential market capacity to provide services consistent in scope and scale with those described in this notice and otherwise anticipated.\nBASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SDVOSB. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions.\n\nSubmission Instructions: Interested parties who consider themselves qualified to perform the above-listed services are invited to submit a response to this Sources Sought Notice by 10:00AM Local Time (Central) on November 11th, 2026. All responses under this Sources Sought Notice shall be emailed to Michelle.Klug2@va.gov.\n\nSTATEMENT OF WORK\nInspections Overview: The Contractor shall perform Annual Category 1, Semiannual, and Full-Load Category 5 VTS component inspection/testing as follows: a. Annual Category 1 inspection/testing is typically conducted in May of each year;\na. Semiannual inspection/testing is typically conducted in November of each year; and\nb. Full-Load Category 5 testing will be performed in November 2027.\nc. Note: Typical inspection/testing dates are subject to change, in FHCC s sole discretion.\nBasic Contractor Responsibilities: The Contractor shall provide all personnel, equipment, material, parts, software, supplies, facilities, transportation, tools, materials, supervision, and other items and non-personal services necessary for execution of the work to be performed under this Contract. Any work found to be non-conforming to the terms of this Contract shall be promptly corrected by the Contractor at no additional cost to the Government. All work shall be performed in a neat and professional manner, including the removal of all trash and debris at the completion of all work.\nContractor Limitations: The Contractor performing inspection/testing under this Contract is prohibited from performing any repairs or other work on any of the VTS components covered by this Contract.\nSafety: All work performed under this Contract shall conform to such safety precautions as the FHCC Fire/Safety and Engineering Departments determine, in their sole discretion, to be necessary, in addition to all other requirements set forth elsewhere in the Contract.\nInspection/Testing Standards.\n1. All inspection/testing of FHCC s vertical transportation system components shall comply with the most current version of the following standards:\n\na. American Society of Mechanical Engineers ( ASME ) 17.1: Handbook on Safety Code for Elevators and Escalators;\nb. ASME 17.2: Guide for Inspection of Elevators, Escalators, and Moving Walks;\nc. ASME 17.3: Safety Code for Existing Elevators and Escalators;\nd. National Fire Protection Association ( NFPA ) 70: National Electrical Code; and\ne. NFPA 70E: Standard for Electrical Safety in the Workplace.\n2. During any inspection/testing, parts shall be removed and equipment cleaned, as necessary, to determine their exact condition. All parts shall be properly reinstalled after removal.\n3. All inspections shall be performed in the presence of an elevator maintenance technician, currently under contract as the VA elevator maintenance contractor, and the COR or designated FHCC representative.\n4. Immediately following the conclusion of each inspection/testing, the Contractor shall brief the COR or designated FHCC representative regarding the inspection/testing results, including without limitation: code violations, safety concerns, and immediate maintenance needs.\n5. The COR, in the COR s sole discretion, may reject any work performed under this Contract that is noncompliant with any of the requirements set forth in this Contract. All rejected work shall be corrected as quickly as reasonably possible at no additional expense to the Government.\nInspection Checklists: The Contractor shall provide a fully completed inspection checklist applicable to each VTS component using the Checklist for Inspection of Electric Elevators The comments section of each checklist shall include a. If the VTS component is safe operating condition;\na. If the VTS component will perform in accordance with Original Equipment Manufacturer ( OEM ) standards;\nb. Whether the VTS component has been altered, except in conformity with all applicable standards set forth in this Contract;\nc. If the VTS component has any deficiencies, referencing the appropriate standard as applicable; and\nd. Whether there are any recommended VTS component repairs or upgrades.\ne. Documentation. Upon completion of the inspection/testing of all FHCC s VTS components, the Contractor shall provide a report within thirty (30) days to the COR and other FHCC personnel as directed. The report shall be electronically submitted in pdf format utilizing word processing to the maximum extent practicable; individual file size shall not exceed 7 MB. Each report should include:\n\nCertificates of Inspection: The Certificate of Inspection for each VTS component shall include the following information: a. Location (building and city/state);\na. Identification number;\nb. Capacity;\nc. Speed;\nd. Date of inspection;\ne. Name of inspector and company;\nf. Inspector s signature; and\ng. Inspector s Qualified Elevator Inspector ( QEI ) number.\nScheduling Inspection/Testing: The Contractor shall coordinate a mutually agreeable time with the COR at least thirty (30) days prior to the typical inspection months, as defined above.\nHours for Inspection/Testing: All work performed under this Contract shall be performed during normal hours of facility operation, as defined below, except for inspection/testing that, in the COR s judgment, may severely impact elevator service. Inspection/testing that severely impacts elevator service shall be conducted after normal hours of facility operation at no additional cost to the Government.\nReinspection: If any VTS component(s) require reinspection, the Contractor shall: a. Provide a quote to the COR for the reinspection(s) at a price consistent with the Price Schedule s Unit Price for the current contract period; and\na. Coordinate reinspection(s) with the COR only after a Contract Modification has been awarded authorizing such reinspection.\nb. Inspector Qualifications. Inspectors performing VTS component inspection/testing under this Contract shall be a currently certified Qualified Elevator Inspector by an ASME-accredited organization, in accordance with ASME QEI-1: Standard for the Qualification of Elevator Inspectors. Inspectors performing work under this Contract shall be regularly employed by the Contractor. The Contractor shall provide a copy of each inspector s QEI-1 certification to the COR prior to any VTS component inspection/testing being performed.\nc. Scheduling.\nd. On-Site Work Requirements. In addition to any other requirements set forth in this Contract, the Contractor shall comply with the following on-site work requirements:\n\nContractor Orientation/Training: The Contractor shall attend an orientation prior to beginning any work under this Contract, at the COR s discretion. This orientation may include the following topics: Contract terms and conditions; performance monitoring; badging procedures; safety; fire procedures; severe weather procedures; disease transmission; infection control; disaster procedures; and any other topic deemed necessary by the COR. At the COR s discretion, the Contractor may be responsible for providing some or all this information/training to its employees, as directed by the COR.\nCheck-in/Check-out Requirements: The Contractor shall comply with all facility check-in and screening requirements. Upon successful completion of the facility s check-in and screening process, the Contractor shall check-in with the COR, or the COR s designee, advising them of the nature and location of the work to be accomplished. The Contractor shall check-out with the COR, or the COR s designee, at the conclusion of such work, prior to departing the VA facility, advising them of the work completed and any problems/issues identified.\nHours of Operation: Normal hours of facility operation ( Business Hours ) are Monday through Friday, 7:00 a.m. 3:30 p.m. Local Time, except for the following Federal Holidays:\n\na. New Year s Day;\na. Birthday of Martin Luther King, Jr.;\nb. Washington s Birthday;\nc. Memorial Day;\nd. Juneteenth National Independence Day;\ne. Independence Day;\nf. Labor Day;\ng. Columbus Day;\nh. Veterans Day;\ni. Thanksgiving Day;\nj. Christmas Day;\n**** Any other day declared a Federal Holiday by Presidential Proclamation****\n\nNoninterference with Facility Functions: The Contractor shall perform its services under this Contract in a manner that does not interfere with the facility s functions, including maintaining all tools and equipment in an orderly fashion and cleaning the work area at the conclusion of a service visit. The Contractor shall interrupt its work at any time to not interfere with the normal functioning of the facility, including utility services, fire protection systems, and passage of facility patients, personnel, equipment, and carts. In the event of an emergency, Contractor\n\nMANUFACTURER\nTYPE\nELEVATOR #\nLOCATION\nInspection Frequency\n1\nSMARTRISE/HW\nTRACTION\nP-1\nBLDG. 133 CA\nAnnual May/Semi-Annual November\n2\nSMARTRISE/HW\nTRACTION\nP-2\nBLDG. 133 CA\nAnnual May/Semi-Annual November\n3\nSMARTRISE/HW\nTRACTION\nP-3\nBLDG. 133 CA\nAnnual May/Semi-Annual November\n4\nMID-AMERICAN\nTRACTION\nP-4\nBLDG. 131\nAnnual May/Semi-Annual November\n5\nMID-AMERICAN\nTRACTION\nP-5\nBLDG. 131\nAnnual May/Semi-Annual November\n6\nSMARTRISE/HW\nTRACTION\nP-7\nBLDG. 133\nAnnual May/Semi-Annual November\n7\nSMARTRISE/HW\nTRACTION\nP-8\nBLDG. 133\nAnnual May/Semi-Annual November\n8\nSMARTRISE\nTRACTION\nP-10\nBLDG. 134\nAnnual May/Semi-Annual November\n9\nSMARTRISE\nTRACTION\nP-11\nBLDG. 134\nAnnual May/Semi-Annual November\n10\nSMARTRISE\nTRACTION\nP-13\nBLDG. 135\nAnnual May/Semi-Annual November\n11\nSMARTRISE\nTRACTION\nP-18\nBLDG. 1\nAnnual May/Semi-Annual November\n12\nMID-AMERICAN\nHYDRAULIC\nP-20\nBLDG. 46\nAnnual May/Semi-Annual November\n13\nMID-AMERICAN\nTRACTION\nP-21\nBLDG. 66\nAnnual May/Semi-Annual November\n14\nMID-AMERICAN\nTRACTION\nP-22\nBLDG. 7\nAnnual May/Semi-Annual November\n15\nMID-AMERICAN\nHYDRAULIC\nP-23\nBLDG. 4\nAnnual May/Semi-Annual November\n16\nMID-AMERICAN\nHYDRAULIC\nP-24\nBLDG. 133\nAnnual May/Semi-Annual November\n17\nSCHUMACKER ELEVATOR\nHYDRAULIC\nP-25\nPARKING GARAGE 195\nAnnual May/Semi-Annual November\n18\nSCHUMACKER ELEVATOR\nHYDRAULIC\nP-26\nPARKING GARAGE\nAnnual May/Semi-Annual November\n19\nSCHUMACKER ELEVATOR\nHYDRAULIC\nP-1\nBLDG. 133EF\nAnnual May/Semi-Annual November\n\n20\nSCHUMACKER ELEVATOR\nHYDRAULIC\nP-2\nBLDG. 133EF\nAnnual May/Semi-Annual November\n21\nSMARTRISE\nHYDRAULIC\nS-1\nBLDG. 133CA\nAnnual May/Semi-Annual November\n22\nSCHUMACKER ELEVATOR\nHYDRAULIC\nS-1\nBLDG. 133EF\nAnnual May/Semi-Annual November\n23\nSCHINDLER\nHYDRAULIC\nS-2\nBLDG. 6\nAnnual May/Semi-Annual November\n24\nSCHINDLER\nHYDRAULIC\nS-3\nBLDG. 6\nAnnual May/Semi-Annual November\n25\nMID-AMERICAN\nTRACTION\nS-6\nBLDG. 131\nAnnual May/Semi-Annual November\n26\nSMARTRISE\nTRACTION\nS-9\nBLDG. 133\nAnnual May/Semi-Annual November\n27\nSMARTRISE\nTRACTION\nS-12\nBLDG. 134\nAnnual May/Semi-Annual November\n28\nSMARTRISE\nTRACTION\nSF-14\nBLDG. 135\nAnnual May/Semi-Annual November\n29\nKONE\nTRACTION\nP-27\nPARKING GARAGE 196\nAnnual May/Semi-Annual November\n30\nTAC32H\nHYDRAULIC\n556FH-ELEV-001-CO100\nCORRIDOR 100\nAnnual May/Semi-Annual November\n31\nSMARTRISE\nHYDRAULIC\n5-ELEV-E1-CO101\nCORRIDOR 101\nAnnual May/Semi-Annual November\nFHCC VERTICAL TRANSPORTATION SYSTEM SCHEDULE ELEVATORS\n\nCART LIFTS\n\nMANUFACTURER\nCART LIFT #\nLOCATION\nINSPECTION FREQUENCY\n1\nLIFT-O-MATIC\nCART LIFT 1\nBLDG. 133CA\nAnnual May/Semi-Annual November\n2\nLIFT-O-MATIC\nCART LIFT 2\nBLDG. 133CA\nAnnual May/Semi-Annual November\n\nDUMBWATIERS\n\nDUMBWAITER #\nLOCATION\nINSPECTION FREQUENCY\n1\nDUMBWAITER 1\nBLDG. 133\nAnnual May/Semi-Annual November\n2\nDUMBWAITER 2\nBLDG. 133CA\nAnnual May/Semi-Annual November","html":"SOURCES SOUGHT SYNOPSIS \nThe Department of Veterans Affairs is issuing this sources sought synopsis as a means of conducting market research to identify parties having an interest in and the resources to support a requirement for Elevator Testing  Services located at FHCC VAMC , North Chicago IL.\n\no Captain James A. Lovell Federal Health Care Center, North Chicago, IL. \n\n\nThe result of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 341350.\nTHERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred. \nBackground: \n\nThe purpose of this Contract is to provide for the inspection/testing of the vertical transportation system located at the Captain James A. Lovell Federal Health Care Center ( FHCC ), 3001 Green Bay Road, North Chicago, IL 60064-3048, as set forth in this Performance Work Statement.  A complete listing of all vertical transportation system components, including thirty-one (31) elevators, two (2) cart lifts, and two (2) dumbwaiters (collectively  VTS components ), is set forth in the Vertical Transportation System Schedule at the end of this Performance Work Statement. Any additional vertical transportation system components put into service after award of this Contract shall be included in the Vertical Transportation System Schedule at price(s) consistent with the current Price Schedule.\nA complete listing of all VTS Components, including twenty-nine (31) elevators, two (2) cart lifts, and two (2) dumbwaiters, is set forth in the Vertical Transportation System Schedule at the end of this Statement of Work. Any additional vertical transportation system components put into service after award of this Contract shall be included in the Vertical Transportation System Inventory at price(s) consistent with the current Price Schedule. \n\nIf your organization has the potential capacity to perform these contract services, please provide the following information: 1) Organization name, address, email address, website address, if applicable, telephone number, and size and type of ownership for the organization; and 2) Tailored capability statements addressing the particulars of this effort and documentation supporting claims of organizational and staff capability. If significant subcontracting or teaming is anticipated in order to deliver technical capability, organizations should address the administrative and management structure of such arrangements. \nThe Government will evaluate market information to ascertain potential market capacity to provide services consistent in scope and scale with those described in this notice and otherwise anticipated. \nBASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SDVOSB.  Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions.  \n\nSubmission Instructions: Interested parties who consider themselves qualified to perform the above-listed services are invited to submit a response to this Sources Sought Notice by 10:00AM Local Time (Central) on November 11th, 2026. All responses under this Sources Sought Notice shall be emailed to Michelle.Klug2@va.gov.\n\n\n\nSTATEMENT OF WORK\nInspections Overview: The Contractor shall perform Annual Category 1, Semiannual, and Full-Load Category 5 VTS component inspection/testing as follows: a. Annual Category 1 inspection/testing is typically conducted in May of each year; \na. Semiannual inspection/testing is typically conducted in November of each year; and \nb. Full-Load Category 5 testing will be performed in November 2027. \nc. Note: Typical inspection/testing dates are subject to change, in FHCC s sole discretion. \nBasic Contractor Responsibilities: The Contractor shall provide all personnel, equipment, material, parts, software, supplies, facilities, transportation, tools, materials, supervision, and other items and non-personal services necessary for execution of the work to be performed under this Contract. Any work found to be non-conforming to the terms of this Contract shall be promptly corrected by the Contractor at no additional cost to the Government. All work shall be performed in a neat and professional manner, including the removal of all trash and debris at the completion of all work. \nContractor Limitations: The Contractor performing inspection/testing under this Contract is prohibited from performing any repairs or other work on any of the VTS components covered by this Contract. \nSafety: All work performed under this Contract shall conform to such safety precautions as the FHCC Fire/Safety and Engineering Departments determine, in their sole discretion, to be necessary, in addition to all other requirements set forth elsewhere in the Contract. \nInspection/Testing Standards. \n1. All inspection/testing of FHCC s vertical transportation system components shall comply with the most current version of the following standards: \n\na. American Society of Mechanical Engineers ( ASME ) 17.1: Handbook on Safety Code for Elevators and Escalators; \nb. ASME 17.2: Guide for Inspection of Elevators, Escalators, and Moving Walks; \nc. ASME 17.3: Safety Code for Existing Elevators and Escalators; \nd. National Fire Protection Association ( NFPA ) 70: National Electrical Code; and \ne. NFPA 70E: Standard for Electrical Safety in the Workplace. \n2. During any inspection/testing, parts shall be removed and equipment cleaned, as necessary, to determine their exact condition. All parts shall be properly reinstalled after removal. \n3. All inspections shall be performed in the presence of an elevator maintenance technician, currently under contract as the VA elevator maintenance contractor, and the COR or designated FHCC representative. \n4. Immediately following the conclusion of each inspection/testing, the Contractor shall brief the COR or designated FHCC representative regarding the inspection/testing results, including without limitation: code violations, safety concerns, and immediate maintenance needs. \n5. The COR, in the COR s sole discretion, may reject any work performed under this Contract that is noncompliant with any of the requirements set forth in this Contract. All rejected work shall be corrected as quickly as reasonably possible at no additional expense to the Government. \nInspection Checklists: The Contractor shall provide a fully completed inspection checklist applicable to each VTS component using the Checklist for Inspection of Electric Elevators The comments section of each checklist shall include a. If the VTS component is safe operating condition; \na. If the VTS component will perform in accordance with Original Equipment Manufacturer ( OEM ) standards; \nb. Whether the VTS component has been altered, except in conformity with all applicable standards set forth in this Contract; \nc. If the VTS component has any deficiencies, referencing the appropriate standard as applicable; and \nd. Whether there are any recommended VTS component repairs or upgrades. \ne. Documentation. Upon completion of the inspection/testing of all FHCC s VTS components, the Contractor shall provide a report within thirty (30) days to the COR and other FHCC personnel as directed. The report shall be electronically submitted in pdf format utilizing word processing to the maximum extent practicable; individual file size shall not exceed 7 MB. Each report should include: \n\n\nCertificates of Inspection: The Certificate of Inspection for each VTS component shall include the following information: a. Location (building and city/state); \na. Identification number; \nb. Capacity; \nc. Speed; \nd. Date of inspection; \ne. Name of inspector and company; \nf. Inspector s signature; and \ng. Inspector s Qualified Elevator Inspector ( QEI ) number. \nScheduling Inspection/Testing: The Contractor shall coordinate a mutually agreeable time with the COR at least thirty (30) days prior to the typical inspection months, as defined above. \n Hours for Inspection/Testing: All work performed under this Contract shall be performed during normal hours of facility operation, as defined below, except for inspection/testing that, in the COR s judgment, may severely impact elevator service. Inspection/testing that severely impacts elevator service shall be conducted after normal hours of facility operation at no additional cost to the Government. \nReinspection: If any VTS component(s) require reinspection, the Contractor shall: a. Provide a quote to the COR for the reinspection(s) at a price consistent with the Price Schedule s Unit Price for the current contract period; and \na. Coordinate reinspection(s) with the COR only after a Contract Modification has been awarded authorizing such reinspection. \nb. Inspector Qualifications. Inspectors performing VTS component inspection/testing under this Contract shall be a currently certified Qualified Elevator Inspector by an ASME-accredited organization, in accordance with ASME QEI-1: Standard for the Qualification of Elevator Inspectors. Inspectors performing work under this Contract shall be regularly employed by the Contractor. The Contractor shall provide a copy of each inspector s QEI-1 certification to the COR prior to any VTS component inspection/testing being performed. \nc. Scheduling. \nd. On-Site Work Requirements. In addition to any other requirements set forth in this Contract, the Contractor shall comply with the following on-site work requirements:\n\nContractor Orientation/Training: The Contractor shall attend an orientation prior to beginning any work under this Contract, at the COR s discretion. This orientation may include the following topics: Contract terms and conditions; performance monitoring; badging procedures; safety; fire procedures; severe weather procedures; disease transmission; infection control; disaster procedures; and any other topic deemed necessary by the COR. At the COR s discretion, the Contractor may be responsible for providing some or all this information/training to its employees, as directed by the COR. \nCheck-in/Check-out Requirements: The Contractor shall comply with all facility check-in and screening requirements. Upon successful completion of the facility s check-in and screening process, the Contractor shall check-in with the COR, or the COR s designee, advising them of the nature and location of the work to be accomplished. The Contractor shall check-out with the COR, or the COR s designee, at the conclusion of such work, prior to departing the VA facility, advising them of the work completed and any problems/issues identified. \nHours of Operation: Normal hours of facility operation ( Business Hours ) are Monday through Friday, 7:00 a.m.   3:30 p.m. Local Time, except for the following Federal Holidays:\n \na. New Year s Day; \na. Birthday of Martin Luther King, Jr.; \nb. Washington s Birthday; \nc. Memorial Day; \nd. Juneteenth National Independence Day; \ne. Independence Day; \nf. Labor Day; \ng. Columbus Day; \nh. Veterans Day; \ni. Thanksgiving Day; \nj. Christmas Day; \n**** Any other day declared a Federal Holiday by Presidential Proclamation**** \n\nNoninterference with Facility Functions: The Contractor shall perform its services under this Contract in a manner that does not interfere with the facility s functions, including maintaining all tools and equipment in an orderly fashion and cleaning the work area at the conclusion of a service visit. The Contractor shall interrupt its work at any time to not interfere with the normal functioning of the facility, including utility services, fire protection systems, and passage of facility patients, personnel, equipment, and carts. In the event of an emergency, Contractor \n\n\n\nMANUFACTURER\nTYPE\nELEVATOR #\nLOCATION\nInspection Frequency\n1\nSMARTRISE/HW\nTRACTION\nP-1\nBLDG. 133 CA\nAnnual May/Semi-Annual November\n2\nSMARTRISE/HW\nTRACTION\nP-2\nBLDG. 133 CA\nAnnual May/Semi-Annual November\n3\nSMARTRISE/HW\nTRACTION\nP-3\nBLDG. 133 CA\nAnnual May/Semi-Annual November\n4\nMID-AMERICAN\nTRACTION\nP-4\nBLDG. 131\nAnnual May/Semi-Annual November\n5\nMID-AMERICAN\nTRACTION\nP-5\nBLDG. 131\nAnnual May/Semi-Annual November\n6\nSMARTRISE/HW\nTRACTION\nP-7\nBLDG. 133\nAnnual May/Semi-Annual November\n7\nSMARTRISE/HW\nTRACTION\nP-8\nBLDG. 133\nAnnual May/Semi-Annual November\n8\nSMARTRISE\nTRACTION\nP-10\nBLDG. 134\nAnnual May/Semi-Annual November\n9\nSMARTRISE\nTRACTION\nP-11\nBLDG. 134\nAnnual May/Semi-Annual November\n10\nSMARTRISE\nTRACTION\nP-13\nBLDG. 135\nAnnual May/Semi-Annual November\n11\nSMARTRISE\nTRACTION\nP-18\nBLDG. 1\nAnnual May/Semi-Annual November\n12\nMID-AMERICAN\nHYDRAULIC\nP-20\nBLDG. 46\nAnnual May/Semi-Annual November\n13\nMID-AMERICAN\nTRACTION\nP-21\nBLDG. 66\nAnnual May/Semi-Annual November\n14\nMID-AMERICAN\nTRACTION\nP-22\nBLDG. 7\nAnnual May/Semi-Annual November\n15\nMID-AMERICAN\nHYDRAULIC\nP-23\nBLDG. 4\nAnnual May/Semi-Annual November\n16\nMID-AMERICAN\nHYDRAULIC\nP-24\nBLDG. 133\nAnnual May/Semi-Annual November\n17\nSCHUMACKER ELEVATOR\nHYDRAULIC\nP-25\nPARKING GARAGE 195\nAnnual May/Semi-Annual November\n18\nSCHUMACKER ELEVATOR\nHYDRAULIC\nP-26\nPARKING GARAGE\nAnnual May/Semi-Annual November\n19\nSCHUMACKER ELEVATOR\nHYDRAULIC\nP-1\nBLDG. 133EF\nAnnual May/Semi-Annual November\n\n20\nSCHUMACKER ELEVATOR\nHYDRAULIC\nP-2\nBLDG. 133EF\nAnnual May/Semi-Annual November\n21\nSMARTRISE\nHYDRAULIC\nS-1\nBLDG. 133CA\nAnnual May/Semi-Annual November\n22\nSCHUMACKER ELEVATOR\nHYDRAULIC\nS-1\nBLDG. 133EF\nAnnual May/Semi-Annual November\n23\nSCHINDLER\nHYDRAULIC\nS-2\nBLDG. 6\nAnnual May/Semi-Annual November\n24\nSCHINDLER\nHYDRAULIC\nS-3\nBLDG. 6\nAnnual May/Semi-Annual November\n25\nMID-AMERICAN\nTRACTION\nS-6\nBLDG. 131\nAnnual May/Semi-Annual November\n26\nSMARTRISE\nTRACTION\nS-9\nBLDG. 133\nAnnual May/Semi-Annual November\n27\nSMARTRISE\nTRACTION\nS-12\nBLDG. 134\nAnnual May/Semi-Annual November\n28\nSMARTRISE\nTRACTION\nSF-14\nBLDG. 135\nAnnual May/Semi-Annual November\n29\nKONE\nTRACTION\nP-27\nPARKING GARAGE 196\nAnnual May/Semi-Annual November\n30\nTAC32H\nHYDRAULIC\n556FH-ELEV-001-CO100\nCORRIDOR 100\nAnnual May/Semi-Annual November\n31\nSMARTRISE\nHYDRAULIC\n5-ELEV-E1-CO101\nCORRIDOR 101\nAnnual May/Semi-Annual November\nFHCC VERTICAL TRANSPORTATION SYSTEM SCHEDULE ELEVATORS\n\n\n\n\nCART LIFTS\n\nMANUFACTURER\nCART LIFT #\nLOCATION\nINSPECTION FREQUENCY\n1\nLIFT-O-MATIC\nCART LIFT 1\nBLDG. 133CA\nAnnual May/Semi-Annual November\n2\nLIFT-O-MATIC\nCART LIFT 2\nBLDG. 133CA\nAnnual May/Semi-Annual November\n\nDUMBWATIERS\n\nDUMBWAITER #\nLOCATION\nINSPECTION FREQUENCY\n1\nDUMBWAITER 1\nBLDG. 133\nAnnual May/Semi-Annual November\n2\nDUMBWAITER 2\nBLDG. 133CA\nAnnual May/Semi-Annual November","origin":"detail"},"contacts":[{"name":"Michelle R Klug","role":"primary","email":"michelle.klug2@va.gov","phone":"224-610-3248","title":"Contract Specialist"}],"place_of_performance":null,"office_address":{"zip":"53214","city":"MILWAUKEE","state":"WI","country":"USA"},"naics_codes":["541350"],"award":{"awardee":{}},"attachments":[{"resource_id":"acce10cc542446a1bbf1223cdbcc7559","name":"36C25227Q0080.docx","kind":"file","mime_type":".docx","size_bytes":36380,"posted_at":"2026-11-03T14:53:08.260Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/acce10cc542446a1bbf1223cdbcc7559/download","mirrored":false}],"awards":[],"related":[{"key":"36C25227Q0069","latest_notice_id":"eed58f84a7f44ac98ced93c2b5e9ec8d","title":"S222--Grease Trap Service-FY27 Base-Tomah VAMC - December 2026 - November 2027","solicitation_number":"36C25227Q0069","notice_type":"o","first_type":"p","first_posted":"2026-11-04","last_posted":"2026-11-19","notices":3,"due_at":"2026-11-27T16:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"562998","psc":"S222","set_aside":"SBA","state":"WI","county":"55081","county_name":"Monroe County","city":"5580075","city_name":"Tomah","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Tomah VA Medical Center","site_key":"tomah-va-medical-center-wi","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C25227Q0033","latest_notice_id":"4d3caf6262ae49649e71c4eadbda1187","title":"Q702--Great Lakes Region Durable Medical Equipment (DME) Delivery Services","solicitation_number":"36C25227Q0033","notice_type":"o","first_type":"o","first_posted":"2026-11-06","last_posted":"2026-11-19","notices":3,"due_at":"2026-11-30T12:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T12:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"621610","psc":"Q702","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C25227B00020001","latest_notice_id":"7eafb50009534028818a8ee9836b9e30","title":"Z1DA--550-20-121 Demo Old Boiler Plant B100 (CON)","solicitation_number":"36C25227B0002-0001","notice_type":"o","first_type":"o","first_posted":"2026-10-21","last_posted":"2026-11-10","notices":2,"due_at":"2026-12-02T19:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"IL","county":"17183","county_name":"Vermilion County","city":"1718563","city_name":"Danville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"36C25227Q0059","latest_notice_id":"356844aa4dfe401da0c9186aa3e03e85","title":"4130--Chiller Compressor Replacement at the Edward Hines Jr. VA Hospital (Hines) Building 228","solicitation_number":"36C25227Q0059","notice_type":"o","first_type":"r","first_posted":"2026-10-16","last_posted":"2026-11-16","notices":2,"due_at":"2026-12-03T16:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"238220","psc":"J043","set_aside":"SDVOSBC","state":"IL","county":"17031","county_name":"Cook County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C25227B0006","latest_notice_id":"e4fa6ced73cf448f9259359ef2b8eeab","title":"Z1DA--537-26-101 Construction of Ogden Elevator Cab Interiors Jesse Brown VA Medical Center","solicitation_number":"36C25227B0006","notice_type":"p","first_type":"p","first_posted":"2026-10-20","last_posted":"2026-10-20","notices":1,"due_at":"2026-12-04T16:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"238290","psc":"Z1DA","set_aside":"SDVOSBC","state":"IL","county":"17031","county_name":"Cook County","city":"1714000","city_name":"Chicago","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":"Jesse Brown VA Medical Center","site_key":"jesse-brown-va-medical-center-il","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-21T04:57:30.751375Z"}],"similar_open":[{"key":"36C25526Q0617","latest_notice_id":"3506983a2af048deaf442eae0f8b8a04","title":"H112--Annual/Sem-i annual fire smoke inspections and auto door services l EKH","solicitation_number":"36C25526Q0617","notice_type":"o","first_type":"r","first_posted":"2026-08-19","last_posted":"2026-11-18","notices":11,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"541350","psc":"H112","set_aside":"SBA","state":"KS","county":"20103","county_name":"Leavenworth County","city":"2039000","city_name":"Leavenworth","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"15DDHQ27R00000001","latest_notice_id":"bf980e13286649b7a1ed1898b4d44b95","title":"Aviation Operations Center (AOC)- Building Engineer Report (BER)","solicitation_number":"15DDHQ27R00000001","notice_type":"k","first_type":"k","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-015","dept_name":"JUSTICE, DEPARTMENT OF","sub_key":"s-1524","sub_name":"DRUG ENFORCEMENT ADMINISTRATION","office_key":"o-15DDFA","office_name":"OFFICE ACQUISITION MANAGEMENT","naics":"541350","psc":"H156","set_aside":"SBA","state":"TX","county":null,"county_name":null,"city":"4827000","city_name":"Fort Worth","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"36C25727Q00310002","latest_notice_id":"c463c6aa97b7496d99268a3c961117de","title":"NTX Elevator Inspection - Amendment","solicitation_number":"36C25727Q0031-0002","notice_type":"k","first_type":"k","first_posted":"2026-11-04","last_posted":"2026-11-04","notices":1,"due_at":"2026-11-30T21:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"541350","psc":"J036","set_aside":"SDVOSBC","state":"TX","county":"48113","county_name":"Dallas County","city":"4819000","city_name":"Dallas","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-05T04:36:35.392694Z"}],"similar_open_total":9,"indexable":true}