{"canonical":"https://sealedbidder.com/opportunities/36c25226q0599","key":"36C25226Q0599","url":"https://sealedbidder.com/opportunities/36c25226q0599","title":"J059--SEPG 441164 EATON UPS (VA-26-00078869) EQUIPMENT - EATON UPS","solicitation_number":"36C25226Q0599","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-07-20T14:00:00Z","first_posted":"2026-07-13","last_posted":"2026-07-13","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"811210","psc":"J059","set_aside":null,"place_state":"WI","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"55079","place_county_name":"Milwaukee County","place_city":"5553000","place_city_name":"Milwaukee","winner":null,"award_amount":null,"publications":[{"notice_id":"3cdadec5ff9243cfb8ee38d892708623","title":"J059--SEPG 441164 EATON UPS (VA-26-00078869) EQUIPMENT - EATON UPS","solicitation_number":"36C25226Q0599","notice_type":"r","base_type":"r","posted":"2026-07-13","posted_at":"2026-07-13T23:18:47.593Z","due_at":"2026-07-20T14:00:00Z","due_date":"2026-07-20","cancelled":false,"archived":true,"archive_date":"2026-08-09","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/3cdadec5ff9243cfb8ee38d892708623/view","enriched":true,"history":[{"index":3,"title":"J059--SEPG 441164 EATON UPS (VA-26-00078869) EQUIPMENT - EATON UPS","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-13T23:18:47.593Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"3cdadec5ff9243cfb8ee38d892708623","solicitation_number":"36C25226Q0599"}]}],"latest_notice_id":"3cdadec5ff9243cfb8ee38d892708623","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-07-13","posted_at":"2026-07-13T23:18:47.593Z","created_at":"2026-07-13T23:18:46.359Z","modified_at":"2026-08-09T05:06:35.021Z","response_deadline":{"raw":"2026-07-20T09:00:00-05:00","utc":"2026-07-20T14:00:00Z","date":"2026-07-20","time":"09:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/3cdadec5ff9243cfb8ee38d892708623/view"},"naics":{"codes":["811210"],"primary":"811210"},"title":"J059--SEPG 441164 EATON UPS (VA-26-00078869) EQUIPMENT - EATON UPS","agency":{"office":{"code":"36C252","name":"252-NETWORK CONTRACT OFFICE 12 (36C252)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"53214","city":"MILWAUKEE","state":"WI","country":"USA"},"organization_id":"100180018","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-09","archive_type":"auto_custom"},"history":[{"index":3,"title":"J059--SEPG 441164 EATON UPS (VA-26-00078869) EQUIPMENT - EATON UPS","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-13T23:18:47.593Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"3cdadec5ff9243cfb8ee38d892708623","solicitation_number":"36C25226Q0599"}],"contacts":[{"name":"Waymon McNeal","role":"primary","email":"waymon.mcnealjr@va.gov","phone":"414-844-4842","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"3cdadec5ff9243cfb8ee38d892708623","lineage_id":"3cdadec5ff9243cfb8ee38d892708623","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-30T00:39:19.891808172Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"2b9e03fffe073a1f31d1f2c38b60c14223b6f8ea55f11ac2567ef70886dc5cad","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-30T00:39:19.891808172Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE.\nÂ \nThe Department of Veterans Affairs (VA) is conducting market research to identify vendors capable of providing a Service Life Extension Program (SLEP) refit and maintenance services for an Eaton 9390 Uninterruptible Power Supply (UPS) system located at the Clement J. Zablocki VA Medical Center 5000 W National Ave Milwaukee, WI 53295-0001.\n\nThe contractor shall provide all labor, supervision, equipment, tools, materials, transportation, and other resources necessary to perform the required services.\n\nThe applicable North American Industry Classification System (NAICS) code for this requirement is 811210   Electronic and Precision Equipment Repair and Maintenance. \n\nThe applicable Product Service Code (PSC) is J059   Maintenance, Repair, and Rebuilding of Equipment   Electrical and Electronic Equipment Components.\n\nScope of Services\n\nService Life Extension Program for the Eaton 9390 480V UPS Serial Number EF413CBB04 at the Milwaukee VAMC.\nInspection of the electronics portion of the Eaton UPS.\nUPS Electronics Replacement Service\n1-year service warranty \n\nTasks or Requirements\n\nInspection of the Eaton UPS Electronics\nInspect the UPS for suitability of the intended Service Life Extension Program electronics replacement service.\nInspect all capacitors, fans, and batteries.\nTest all power transfer conditions.\nInspect performance history of the UPS.\n\nReplace the following UPS Electronics\nAll Power Modules\nPower Supplies\nControl and interface boards\nTerminal Blocks\nMini CSB Communication Card\n\nProvide the following UPS maintenance services\nClean contactors, wiring, and other electrical components, and replace them as needed.\nUpdate firmware\nCalibration and functional testing of the UPS\n\n1-Year service life extension program warranty\nCorrective maintenance parts and labor warranty coverage. Excludes battery, capacitor, and fan replacement.\nCorrective maintenance support availability 24 hours per day, 7 days per week.\n8-hour on-site response time to emergency corrective maintenance requests.\n\nEntitlement to purchase service contract coverage from Eaton for a minimum of 10 years, through 2037.\n\nReplaced parts become property of Eaton and Eaton shall promptly dispose of replaced parts in accordance with applicable regulations.\n\nSelection Criteria\nCompletion of this equipment upgrade shall provide Milwaukee VAMC with entitlement to purchase service contract coverage from Eaton for a minimum of 10 years, through 2037.\n\nPlace of Performance\nMilwaukee VA Medical Center\nMedical Imaging Department, Room 2476, Building 111\n5000 W National Ave\nMilwaukee, Wi 53295\n\nPeriod of Performance\n10/1/2026-9/30/2027\n\n\nCapability Statement Submission\n\nInterested vendors shall submit a capability statement demonstrating experience performing UPS maintenance, repair, or SLEP services.\nCapability statements should include company name, address, UEI or DUNS number, point of contact, business size under NAICS 811210, and socioeconomic status.\nVendors should demonstrate experience servicing Eaton or equivalent UPS systems and provide qualifications of Field Service Engineers.\nCapability statements must be submitted no later than Monday, July 20, 2026, at 9:00 AM CST.\nResponses shall be submitted via email to Contracting Officer, Waymon McNeal, at Waymon.McNealjr@va.gov.\n36C25226Q0599 Service Life Extension shall be referenced on all correspondence regarding this announcement.\n\n\n\nDisclaimer\nThis Sources Sought notice is issued solely for information and planning purposes and does not\nconstitute a solicitation. This is not a Request for Proposal (RFP). The Government is seeking\ninformation for market research purposes only. The Government may or may not issue solicitation in the future. \n\n\n\nTelephone inquiries will not be accepted.","text":"THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE.\nÂ\nThe Department of Veterans Affairs (VA) is conducting market research to identify vendors capable of providing a Service Life Extension Program (SLEP) refit and maintenance services for an Eaton 9390 Uninterruptible Power Supply (UPS) system located at the Clement J. Zablocki VA Medical Center 5000 W National Ave Milwaukee, WI 53295-0001.\n\nThe contractor shall provide all labor, supervision, equipment, tools, materials, transportation, and other resources necessary to perform the required services.\n\nThe applicable North American Industry Classification System (NAICS) code for this requirement is 811210 Electronic and Precision Equipment Repair and Maintenance.\n\nThe applicable Product Service Code (PSC) is J059 Maintenance, Repair, and Rebuilding of Equipment Electrical and Electronic Equipment Components.\n\nScope of Services\n\nService Life Extension Program for the Eaton 9390 480V UPS Serial Number EF413CBB04 at the Milwaukee VAMC.\nInspection of the electronics portion of the Eaton UPS.\nUPS Electronics Replacement Service\n1-year service warranty\n\nTasks or Requirements\n\nInspection of the Eaton UPS Electronics\nInspect the UPS for suitability of the intended Service Life Extension Program electronics replacement service.\nInspect all capacitors, fans, and batteries.\nTest all power transfer conditions.\nInspect performance history of the UPS.\n\nReplace the following UPS Electronics\nAll Power Modules\nPower Supplies\nControl and interface boards\nTerminal Blocks\nMini CSB Communication Card\n\nProvide the following UPS maintenance services\nClean contactors, wiring, and other electrical components, and replace them as needed.\nUpdate firmware\nCalibration and functional testing of the UPS\n\n1-Year service life extension program warranty\nCorrective maintenance parts and labor warranty coverage. Excludes battery, capacitor, and fan replacement.\nCorrective maintenance support availability 24 hours per day, 7 days per week.\n8-hour on-site response time to emergency corrective maintenance requests.\n\nEntitlement to purchase service contract coverage from Eaton for a minimum of 10 years, through 2037.\n\nReplaced parts become property of Eaton and Eaton shall promptly dispose of replaced parts in accordance with applicable regulations.\n\nSelection Criteria\nCompletion of this equipment upgrade shall provide Milwaukee VAMC with entitlement to purchase service contract coverage from Eaton for a minimum of 10 years, through 2037.\n\nPlace of Performance\nMilwaukee VA Medical Center\nMedical Imaging Department, Room 2476, Building 111\n5000 W National Ave\nMilwaukee, Wi 53295\n\nPeriod of Performance\n10/1/2026-9/30/2027\n\nCapability Statement Submission\n\nInterested vendors shall submit a capability statement demonstrating experience performing UPS maintenance, repair, or SLEP services.\nCapability statements should include company name, address, UEI or DUNS number, point of contact, business size under NAICS 811210, and socioeconomic status.\nVendors should demonstrate experience servicing Eaton or equivalent UPS systems and provide qualifications of Field Service Engineers.\nCapability statements must be submitted no later than Monday, July 20, 2026, at 9:00 AM CST.\nResponses shall be submitted via email to Contracting Officer, Waymon McNeal, at Waymon.McNealjr@va.gov.\n36C25226Q0599 Service Life Extension shall be referenced on all correspondence regarding this announcement.\n\nDisclaimer\nThis Sources Sought notice is issued solely for information and planning purposes and does not\nconstitute a solicitation. This is not a Request for Proposal (RFP). The Government is seeking\ninformation for market research purposes only. The Government may or may not issue solicitation in the future.\n\nTelephone inquiries will not be accepted.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25226Q0599","place_of_performance":{"zip":"53295-0001","city":{"name":"Milwaukee"},"state":{"name":"WI"},"street":"Clement J. Zablocki VA Medical Center 5000 W National Ave","country":{"name":"United States"}},"product_service_code":"J059"}],"due_at":"2026-07-20T14:00:00Z","due_date":"2026-07-20","closes_at":"2026-07-20T14:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","state":"WI","county":"55079","county_name":"Milwaukee County","city":"5553000","city_name":"Milwaukee","country":null,"state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-02T08:44:04.547541Z","principal_notice_id":"3cdadec5ff9243cfb8ee38d892708623","description":{"text":"THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE.\nÂ\nThe Department of Veterans Affairs (VA) is conducting market research to identify vendors capable of providing a Service Life Extension Program (SLEP) refit and maintenance services for an Eaton 9390 Uninterruptible Power Supply (UPS) system located at the Clement J. Zablocki VA Medical Center 5000 W National Ave Milwaukee, WI 53295-0001.\n\nThe contractor shall provide all labor, supervision, equipment, tools, materials, transportation, and other resources necessary to perform the required services.\n\nThe applicable North American Industry Classification System (NAICS) code for this requirement is 811210 Electronic and Precision Equipment Repair and Maintenance.\n\nThe applicable Product Service Code (PSC) is J059 Maintenance, Repair, and Rebuilding of Equipment Electrical and Electronic Equipment Components.\n\nScope of Services\n\nService Life Extension Program for the Eaton 9390 480V UPS Serial Number EF413CBB04 at the Milwaukee VAMC.\nInspection of the electronics portion of the Eaton UPS.\nUPS Electronics Replacement Service\n1-year service warranty\n\nTasks or Requirements\n\nInspection of the Eaton UPS Electronics\nInspect the UPS for suitability of the intended Service Life Extension Program electronics replacement service.\nInspect all capacitors, fans, and batteries.\nTest all power transfer conditions.\nInspect performance history of the UPS.\n\nReplace the following UPS Electronics\nAll Power Modules\nPower Supplies\nControl and interface boards\nTerminal Blocks\nMini CSB Communication Card\n\nProvide the following UPS maintenance services\nClean contactors, wiring, and other electrical components, and replace them as needed.\nUpdate firmware\nCalibration and functional testing of the UPS\n\n1-Year service life extension program warranty\nCorrective maintenance parts and labor warranty coverage. Excludes battery, capacitor, and fan replacement.\nCorrective maintenance support availability 24 hours per day, 7 days per week.\n8-hour on-site response time to emergency corrective maintenance requests.\n\nEntitlement to purchase service contract coverage from Eaton for a minimum of 10 years, through 2037.\n\nReplaced parts become property of Eaton and Eaton shall promptly dispose of replaced parts in accordance with applicable regulations.\n\nSelection Criteria\nCompletion of this equipment upgrade shall provide Milwaukee VAMC with entitlement to purchase service contract coverage from Eaton for a minimum of 10 years, through 2037.\n\nPlace of Performance\nMilwaukee VA Medical Center\nMedical Imaging Department, Room 2476, Building 111\n5000 W National Ave\nMilwaukee, Wi 53295\n\nPeriod of Performance\n10/1/2026-9/30/2027\n\nCapability Statement Submission\n\nInterested vendors shall submit a capability statement demonstrating experience performing UPS maintenance, repair, or SLEP services.\nCapability statements should include company name, address, UEI or DUNS number, point of contact, business size under NAICS 811210, and socioeconomic status.\nVendors should demonstrate experience servicing Eaton or equivalent UPS systems and provide qualifications of Field Service Engineers.\nCapability statements must be submitted no later than Monday, July 20, 2026, at 9:00 AM CST.\nResponses shall be submitted via email to Contracting Officer, Waymon McNeal, at Waymon.McNealjr@va.gov.\n36C25226Q0599 Service Life Extension shall be referenced on all correspondence regarding this announcement.\n\nDisclaimer\nThis Sources Sought notice is issued solely for information and planning purposes and does not\nconstitute a solicitation. This is not a Request for Proposal (RFP). The Government is seeking\ninformation for market research purposes only. The Government may or may not issue solicitation in the future.\n\nTelephone inquiries will not be accepted.","html":"THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE.\nÂ \nThe Department of Veterans Affairs (VA) is conducting market research to identify vendors capable of providing a Service Life Extension Program (SLEP) refit and maintenance services for an Eaton 9390 Uninterruptible Power Supply (UPS) system located at the Clement J. Zablocki VA Medical Center 5000 W National Ave Milwaukee, WI 53295-0001.\n\nThe contractor shall provide all labor, supervision, equipment, tools, materials, transportation, and other resources necessary to perform the required services.\n\nThe applicable North American Industry Classification System (NAICS) code for this requirement is 811210   Electronic and Precision Equipment Repair and Maintenance. \n\nThe applicable Product Service Code (PSC) is J059   Maintenance, Repair, and Rebuilding of Equipment   Electrical and Electronic Equipment Components.\n\nScope of Services\n\nService Life Extension Program for the Eaton 9390 480V UPS Serial Number EF413CBB04 at the Milwaukee VAMC.\nInspection of the electronics portion of the Eaton UPS.\nUPS Electronics Replacement Service\n1-year service warranty \n\nTasks or Requirements\n\nInspection of the Eaton UPS Electronics\nInspect the UPS for suitability of the intended Service Life Extension Program electronics replacement service.\nInspect all capacitors, fans, and batteries.\nTest all power transfer conditions.\nInspect performance history of the UPS.\n\nReplace the following UPS Electronics\nAll Power Modules\nPower Supplies\nControl and interface boards\nTerminal Blocks\nMini CSB Communication Card\n\nProvide the following UPS maintenance services\nClean contactors, wiring, and other electrical components, and replace them as needed.\nUpdate firmware\nCalibration and functional testing of the UPS\n\n1-Year service life extension program warranty\nCorrective maintenance parts and labor warranty coverage. Excludes battery, capacitor, and fan replacement.\nCorrective maintenance support availability 24 hours per day, 7 days per week.\n8-hour on-site response time to emergency corrective maintenance requests.\n\nEntitlement to purchase service contract coverage from Eaton for a minimum of 10 years, through 2037.\n\nReplaced parts become property of Eaton and Eaton shall promptly dispose of replaced parts in accordance with applicable regulations.\n\nSelection Criteria\nCompletion of this equipment upgrade shall provide Milwaukee VAMC with entitlement to purchase service contract coverage from Eaton for a minimum of 10 years, through 2037.\n\nPlace of Performance\nMilwaukee VA Medical Center\nMedical Imaging Department, Room 2476, Building 111\n5000 W National Ave\nMilwaukee, Wi 53295\n\nPeriod of Performance\n10/1/2026-9/30/2027\n\n\nCapability Statement Submission\n\nInterested vendors shall submit a capability statement demonstrating experience performing UPS maintenance, repair, or SLEP services.\nCapability statements should include company name, address, UEI or DUNS number, point of contact, business size under NAICS 811210, and socioeconomic status.\nVendors should demonstrate experience servicing Eaton or equivalent UPS systems and provide qualifications of Field Service Engineers.\nCapability statements must be submitted no later than Monday, July 20, 2026, at 9:00 AM CST.\nResponses shall be submitted via email to Contracting Officer, Waymon McNeal, at Waymon.McNealjr@va.gov.\n36C25226Q0599 Service Life Extension shall be referenced on all correspondence regarding this announcement.\n\n\n\nDisclaimer\nThis Sources Sought notice is issued solely for information and planning purposes and does not\nconstitute a solicitation. This is not a Request for Proposal (RFP). The Government is seeking\ninformation for market research purposes only. The Government may or may not issue solicitation in the future. \n\n\n\nTelephone inquiries will not be accepted.","origin":"detail"},"contacts":[{"name":"Waymon McNeal","role":"primary","email":"waymon.mcnealjr@va.gov","phone":"414-844-4842","title":"Contract Specialist"}],"place_of_performance":{"zip":"53295-0001","city":{"name":"Milwaukee"},"state":{"name":"WI"},"street":"Clement J. Zablocki VA Medical Center 5000 W National Ave","country":{"name":"United States"}},"office_address":{"zip":"53214","city":"MILWAUKEE","state":"WI","country":"USA"},"naics_codes":["811210"],"award":{"awardee":{}},"attachments":[{"resource_id":"386b1a393edd452a92d6b07fbfa6b702","name":"36C25226Q0599.docx","kind":"file","mime_type":".docx","size_bytes":18400,"posted_at":"2026-07-13T23:18:47.593Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/386b1a393edd452a92d6b07fbfa6b702/download","mirrored":false}],"awards":[],"related":[{"key":"36C25227Q0069","latest_notice_id":"eed58f84a7f44ac98ced93c2b5e9ec8d","title":"S222--Grease Trap Service-FY27 Base-Tomah VAMC - December 2026 - November 2027","solicitation_number":"36C25227Q0069","notice_type":"o","first_type":"p","first_posted":"2026-11-04","last_posted":"2026-11-19","notices":3,"due_at":"2026-11-27T16:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"562998","psc":"S222","set_aside":"SBA","state":"WI","county":"55081","county_name":"Monroe County","city":"5580075","city_name":"Tomah","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Tomah VA Medical Center","site_key":"tomah-va-medical-center-wi","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C25227Q0033","latest_notice_id":"4d3caf6262ae49649e71c4eadbda1187","title":"Q702--Great Lakes Region Durable Medical Equipment (DME) Delivery Services","solicitation_number":"36C25227Q0033","notice_type":"o","first_type":"o","first_posted":"2026-11-06","last_posted":"2026-11-19","notices":3,"due_at":"2026-11-30T12:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T12:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"621610","psc":"Q702","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C25227B00020001","latest_notice_id":"7eafb50009534028818a8ee9836b9e30","title":"Z1DA--550-20-121 Demo Old Boiler Plant B100 (CON)","solicitation_number":"36C25227B0002-0001","notice_type":"o","first_type":"o","first_posted":"2026-10-21","last_posted":"2026-11-10","notices":2,"due_at":"2026-12-02T19:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"IL","county":"17183","county_name":"Vermilion County","city":"1718563","city_name":"Danville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"36C25227Q0059","latest_notice_id":"356844aa4dfe401da0c9186aa3e03e85","title":"4130--Chiller Compressor Replacement at the Edward Hines Jr. VA Hospital (Hines) Building 228","solicitation_number":"36C25227Q0059","notice_type":"o","first_type":"r","first_posted":"2026-10-16","last_posted":"2026-11-16","notices":2,"due_at":"2026-12-03T16:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"238220","psc":"J043","set_aside":"SDVOSBC","state":"IL","county":"17031","county_name":"Cook County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C25227B0006","latest_notice_id":"e4fa6ced73cf448f9259359ef2b8eeab","title":"Z1DA--537-26-101 Construction of Ogden Elevator Cab Interiors Jesse Brown VA Medical Center","solicitation_number":"36C25227B0006","notice_type":"p","first_type":"p","first_posted":"2026-10-20","last_posted":"2026-10-20","notices":1,"due_at":"2026-12-04T16:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"238290","psc":"Z1DA","set_aside":"SDVOSBC","state":"IL","county":"17031","county_name":"Cook County","city":"1714000","city_name":"Chicago","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":"Jesse Brown VA Medical Center","site_key":"jesse-brown-va-medical-center-il","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-21T04:57:30.751375Z"}],"similar_open":[{"key":"RFQ24627Q0002","latest_notice_id":"e05660a6946c41cbbef2606eb5b24b46","title":"Full-service maintenance, inspection, calibration, and repair of a body plethysmograph system","solicitation_number":"RFQ24627Q0002","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-25T22:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7527","sub_name":"INDIAN HEALTH SERVICE","office_key":"o-75H721","office_name":"LAWTON INDIAN HOSPITAL","naics":"811210","psc":"J065","set_aside":"SBA","state":"OK","county":"40031","county_name":"Comanche County","city":"4041850","city_name":"Lawton","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"75N98027Q00080","latest_notice_id":"046af05910ad4f4092a269aefe7c0850","title":"Preventive Maintenance Service - GE TracerLab","solicitation_number":"75N98027Q00080","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-27T14:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"811210","psc":"J066","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"36C26227Q0063","latest_notice_id":"57c32e663caa45e58aecf5d9fcc6fe70","title":"J065--ALCON CONSTELLATION LXT AND EMBEDDED LASERS & ALCON CENTURION VISION PHACOEMULSIFICATION PMI SVCS","solicitation_number":"36C26227Q0063","notice_type":"k","first_type":"r","first_posted":"2026-10-21","last_posted":"2026-11-20","notices":3,"due_at":"2026-11-27T19:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"811210","psc":"J065","set_aside":"SDVOSBC","state":"CA","county":"06037","county_name":"Los Angeles County","city":"0643000","city_name":"Long Beach","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":59,"indexable":false}