{"canonical":"https://sealedbidder.com/opportunities/36c25226q0596","key":"36C25226Q0596","url":"https://sealedbidder.com/opportunities/36c25226q0596","title":"6515--Sources Sought Ceiling lift for Milwaukee VA.","solicitation_number":"36C25226Q0596","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-07-22T04:59:00Z","first_posted":"2026-07-13","last_posted":"2026-07-13","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"339112","psc":"6515","set_aside":null,"place_state":null,"place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":"Product purchase (PSC 6515)","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"96c61c47427b4266bf84347f4f45c8aa","title":"6515--Sources Sought Ceiling lift for Milwaukee VA.","solicitation_number":"36C25226Q0596","notice_type":"r","base_type":"r","posted":"2026-07-13","posted_at":"2026-07-13T13:13:53.905Z","due_at":"2026-07-22T04:59:00Z","due_date":"2026-07-21","cancelled":false,"archived":true,"archive_date":"2026-08-21","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/96c61c47427b4266bf84347f4f45c8aa/view","enriched":true,"history":[{"index":3,"title":"6515--Sources Sought Ceiling lift for Milwaukee VA.","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-13T13:13:53.905Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"96c61c47427b4266bf84347f4f45c8aa","solicitation_number":"36C25226Q0596"}]}],"latest_notice_id":"96c61c47427b4266bf84347f4f45c8aa","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-07-13","posted_at":"2026-07-13T13:13:53.905Z","created_at":"2026-07-13T13:13:51.678Z","modified_at":"2026-08-21T05:06:34.612Z","response_deadline":{"raw":"2026-07-21T23:59:00-05:00","utc":"2026-07-22T04:59:00Z","date":"2026-07-21","time":"23:59:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/96c61c47427b4266bf84347f4f45c8aa/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"6515--Sources Sought Ceiling lift for Milwaukee VA.","agency":{"office":{"code":"36C252","name":"252-NETWORK CONTRACT OFFICE 12 (36C252)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"53214","city":"MILWAUKEE","state":"WI","country":"USA"},"organization_id":"100180018","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-21","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--Sources Sought Ceiling lift for Milwaukee VA.","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-13T13:13:53.905Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"96c61c47427b4266bf84347f4f45c8aa","solicitation_number":"36C25226Q0596"}],"contacts":[{"name":"Matthew Hohl","role":"primary","email":"Matthew.hohl@va.gov","phone":"Matthew.hohl@va.gov","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"96c61c47427b4266bf84347f4f45c8aa","lineage_id":"96c61c47427b4266bf84347f4f45c8aa","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-30T01:00:34.497332880Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"056ad84e7fa3ad353e2267bae03b273a6f2793a2a4a3dafea98b883b6c9d3cf0","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-30T01:00:34.497332880Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"Page 2 of 3\n\nTHIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE.\n\nThe NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI 53214, is performing market research to determine if there is a sufficient number of qualified: (1) Service Disabled Veteran Owned Small Business (SDVOSB); (2) Veteran Owned Small Business (VOSB); or (3) Small or emerging small business firms, or (4) Other Than Small business firms, to provide Ceiling Lift for the Milwaukee VAMC.\n\nGeneral Requirements:\n\nSalient Characteristics:\ni. The Lift Unit shall be constructed of a steel frame system driven by a gear-reduced, high-torque, horizontal axis motor.\n1. The ceiling lift motor shall have an integrated Class III scale that allows users to read weights off the hand control.\n2. 2 lifts with minimum 770 lbs weight capacity\na. Weight capacity shall be achieved using a single lift motor\n3. Electronic soft-start and soft-stop motor control.\n4. Shall have an emergency manual lowering device. This emergency manual lowering device cord shall be red. Operation of the emergency manual lowering device shall be in such a way that users can apply continuous pull to the cord to facilitate slow descent of the patient.\n5. Emergency stopping device.\n6. Current limiter for circuit protection in case of overload.\n7. Safety device that stops the motor to lift when batteries are low.\n8. Emergency brake (in case of mechanical failure).\n9. Hanger bar shall be able to reach the floor.\n10. Cab: VO plastic fire retardant, UL 94.\n11. Hand controller shall be able to be stored securely to the hanger bar.\n12. The safe working load of the ceiling lift motor shall be clearly labeled on the outside of the ceiling lift motor.\n13. The life cycle (number of charging cycles) for batteries shall comply with IEC 6100-1-2.\n14. Provide rechargeable batteries with up to 120 transfers with a load of 200lbs (74kg) (for repositioning)\n15. The ceiling lift system (motor/hanger assembly) shall be approved for use with Guldmann Repositioning, High Back, Twin Turner and Limb Lifter loop slings.\nii. Two (2) Basic High Slings:\n1. The straps shall meet ISO 10535, Appendix A guidelines. The straps shall ensure the patient s safety by preventing the patient from falling out of the sling.\n2. The sling shall meet ISO 10535, Appendix A guidelines. The sling shall cradle the body of the patient. Bariatric slings shall be rated to a minimum of 770 lbs.\niii. Two (2) Hanger Bars: The hanger bar style shall be the four (4) suspension point style compatible with the lift strap.\niv. Continuous charge track systems\n1. Two (2) Double Rail continuous charge track systems with bathroom access\n2. The Ceiling Track shall be made from high strength extruded aluminum. Provide anchor supports at ceiling substrate\n3. Installed rail shall be security tested for 1.5 times greater than the motor s weight capacity and maximum allowable deflection of a horizontal rail is no more than 1/16th inch per 7.87 inch of track length per ISO 10535 standards.\n\n\nAll interested firms who can meet the requirements stated above should respond, in writing,\nINCLUDING ALL THE FOLLOWING:\nCompany name.\nAddress.\nPoint of contact (name/title/telephone number/e-mail address).\nFSS / SEWP Contract number, if applicable.\nSAM Unique ID number.\nTax ID number.\nIndication of which business category (SDVOSB, VOSB, Small Business or Other Than Small Business) for which the organization qualifies.\nA capability statement that addresses the organizations qualifications and ability to provide the requirement depicted above.\nDocumentation from manufacturer (i.e. correspondence from manufacturer) of your firm being an authorized distributor for the manufacturer.\nLocation of Manufacturer\n\n\nSubmit responses to the Contracting Specialist, Matthew Hohl, at Matthew.Hohl@va.gov no later than 11:59 PM (Central Standard Time), July 21st  2026.\n\n36C25226Q0596 Ceiling lift-3215 shall be referenced on all correspondence regarding this announcement.\n\nTELEPHONIC INQUIRIES WILL NOT BE ACCEPTED.\n\nThe NAICS Code 339112, Surgical and Medical Instrument Manufacturing, is applicable to this acquisition; the size standard is 1,000 employees. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Systems for Award Management (SAM) database prior to award of a contract. The Government will use responses to this notice to make an appropriate acquisition decision. This is the only notice; no other copies of this notice will be provided.","text":"Page 2 of 3\n\nTHIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE.\n\nThe NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI 53214, is performing market research to determine if there is a sufficient number of qualified: (1) Service Disabled Veteran Owned Small Business (SDVOSB); (2) Veteran Owned Small Business (VOSB); or (3) Small or emerging small business firms, or (4) Other Than Small business firms, to provide Ceiling Lift for the Milwaukee VAMC.\n\nGeneral Requirements:\n\nSalient Characteristics:\ni. The Lift Unit shall be constructed of a steel frame system driven by a gear-reduced, high-torque, horizontal axis motor.\n1. The ceiling lift motor shall have an integrated Class III scale that allows users to read weights off the hand control.\n2. 2 lifts with minimum 770 lbs weight capacity\na. Weight capacity shall be achieved using a single lift motor\n3. Electronic soft-start and soft-stop motor control.\n4. Shall have an emergency manual lowering device. This emergency manual lowering device cord shall be red. Operation of the emergency manual lowering device shall be in such a way that users can apply continuous pull to the cord to facilitate slow descent of the patient.\n5. Emergency stopping device.\n6. Current limiter for circuit protection in case of overload.\n7. Safety device that stops the motor to lift when batteries are low.\n8. Emergency brake (in case of mechanical failure).\n9. Hanger bar shall be able to reach the floor.\n10. Cab: VO plastic fire retardant, UL 94.\n11. Hand controller shall be able to be stored securely to the hanger bar.\n12. The safe working load of the ceiling lift motor shall be clearly labeled on the outside of the ceiling lift motor.\n13. The life cycle (number of charging cycles) for batteries shall comply with IEC 6100-1-2.\n14. Provide rechargeable batteries with up to 120 transfers with a load of 200lbs (74kg) (for repositioning)\n15. The ceiling lift system (motor/hanger assembly) shall be approved for use with Guldmann Repositioning, High Back, Twin Turner and Limb Lifter loop slings.\nii. Two (2) Basic High Slings:\n1. The straps shall meet ISO 10535, Appendix A guidelines. The straps shall ensure the patient s safety by preventing the patient from falling out of the sling.\n2. The sling shall meet ISO 10535, Appendix A guidelines. The sling shall cradle the body of the patient. Bariatric slings shall be rated to a minimum of 770 lbs.\niii. Two (2) Hanger Bars: The hanger bar style shall be the four (4) suspension point style compatible with the lift strap.\niv. Continuous charge track systems\n1. Two (2) Double Rail continuous charge track systems with bathroom access\n2. The Ceiling Track shall be made from high strength extruded aluminum. Provide anchor supports at ceiling substrate\n3. Installed rail shall be security tested for 1.5 times greater than the motor s weight capacity and maximum allowable deflection of a horizontal rail is no more than 1/16th inch per 7.87 inch of track length per ISO 10535 standards.\n\nAll interested firms who can meet the requirements stated above should respond, in writing,\nINCLUDING ALL THE FOLLOWING:\nCompany name.\nAddress.\nPoint of contact (name/title/telephone number/e-mail address).\nFSS / SEWP Contract number, if applicable.\nSAM Unique ID number.\nTax ID number.\nIndication of which business category (SDVOSB, VOSB, Small Business or Other Than Small Business) for which the organization qualifies.\nA capability statement that addresses the organizations qualifications and ability to provide the requirement depicted above.\nDocumentation from manufacturer (i.e. correspondence from manufacturer) of your firm being an authorized distributor for the manufacturer.\nLocation of Manufacturer\n\nSubmit responses to the Contracting Specialist, Matthew Hohl, at Matthew.Hohl@va.gov no later than 11:59 PM (Central Standard Time), July 21st 2026.\n\n36C25226Q0596 Ceiling lift-3215 shall be referenced on all correspondence regarding this announcement.\n\nTELEPHONIC INQUIRIES WILL NOT BE ACCEPTED.\n\nThe NAICS Code 339112, Surgical and Medical Instrument Manufacturing, is applicable to this acquisition; the size standard is 1,000 employees. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Systems for Award Management (SAM) database prior to award of a contract. The Government will use responses to this notice to make an appropriate acquisition decision. This is the only notice; no other copies of this notice will be provided.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25226Q0596","place_of_performance":{"street":"Milwaukee VA 53295"},"product_service_code":"6515"}],"due_at":"2026-07-22T04:59:00Z","due_date":"2026-07-21","closes_at":"2026-07-22T04:59:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":null,"state_evidence":"Product purchase (PSC 6515)","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-30T01:15:58.983134Z","principal_notice_id":"96c61c47427b4266bf84347f4f45c8aa","description":{"text":"Page 2 of 3\n\nTHIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE.\n\nThe NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI 53214, is performing market research to determine if there is a sufficient number of qualified: (1) Service Disabled Veteran Owned Small Business (SDVOSB); (2) Veteran Owned Small Business (VOSB); or (3) Small or emerging small business firms, or (4) Other Than Small business firms, to provide Ceiling Lift for the Milwaukee VAMC.\n\nGeneral Requirements:\n\nSalient Characteristics:\ni. The Lift Unit shall be constructed of a steel frame system driven by a gear-reduced, high-torque, horizontal axis motor.\n1. The ceiling lift motor shall have an integrated Class III scale that allows users to read weights off the hand control.\n2. 2 lifts with minimum 770 lbs weight capacity\na. Weight capacity shall be achieved using a single lift motor\n3. Electronic soft-start and soft-stop motor control.\n4. Shall have an emergency manual lowering device. This emergency manual lowering device cord shall be red. Operation of the emergency manual lowering device shall be in such a way that users can apply continuous pull to the cord to facilitate slow descent of the patient.\n5. Emergency stopping device.\n6. Current limiter for circuit protection in case of overload.\n7. Safety device that stops the motor to lift when batteries are low.\n8. Emergency brake (in case of mechanical failure).\n9. Hanger bar shall be able to reach the floor.\n10. Cab: VO plastic fire retardant, UL 94.\n11. Hand controller shall be able to be stored securely to the hanger bar.\n12. The safe working load of the ceiling lift motor shall be clearly labeled on the outside of the ceiling lift motor.\n13. The life cycle (number of charging cycles) for batteries shall comply with IEC 6100-1-2.\n14. Provide rechargeable batteries with up to 120 transfers with a load of 200lbs (74kg) (for repositioning)\n15. The ceiling lift system (motor/hanger assembly) shall be approved for use with Guldmann Repositioning, High Back, Twin Turner and Limb Lifter loop slings.\nii. Two (2) Basic High Slings:\n1. The straps shall meet ISO 10535, Appendix A guidelines. The straps shall ensure the patient s safety by preventing the patient from falling out of the sling.\n2. The sling shall meet ISO 10535, Appendix A guidelines. The sling shall cradle the body of the patient. Bariatric slings shall be rated to a minimum of 770 lbs.\niii. Two (2) Hanger Bars: The hanger bar style shall be the four (4) suspension point style compatible with the lift strap.\niv. Continuous charge track systems\n1. Two (2) Double Rail continuous charge track systems with bathroom access\n2. The Ceiling Track shall be made from high strength extruded aluminum. Provide anchor supports at ceiling substrate\n3. Installed rail shall be security tested for 1.5 times greater than the motor s weight capacity and maximum allowable deflection of a horizontal rail is no more than 1/16th inch per 7.87 inch of track length per ISO 10535 standards.\n\nAll interested firms who can meet the requirements stated above should respond, in writing,\nINCLUDING ALL THE FOLLOWING:\nCompany name.\nAddress.\nPoint of contact (name/title/telephone number/e-mail address).\nFSS / SEWP Contract number, if applicable.\nSAM Unique ID number.\nTax ID number.\nIndication of which business category (SDVOSB, VOSB, Small Business or Other Than Small Business) for which the organization qualifies.\nA capability statement that addresses the organizations qualifications and ability to provide the requirement depicted above.\nDocumentation from manufacturer (i.e. correspondence from manufacturer) of your firm being an authorized distributor for the manufacturer.\nLocation of Manufacturer\n\nSubmit responses to the Contracting Specialist, Matthew Hohl, at Matthew.Hohl@va.gov no later than 11:59 PM (Central Standard Time), July 21st 2026.\n\n36C25226Q0596 Ceiling lift-3215 shall be referenced on all correspondence regarding this announcement.\n\nTELEPHONIC INQUIRIES WILL NOT BE ACCEPTED.\n\nThe NAICS Code 339112, Surgical and Medical Instrument Manufacturing, is applicable to this acquisition; the size standard is 1,000 employees. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Systems for Award Management (SAM) database prior to award of a contract. The Government will use responses to this notice to make an appropriate acquisition decision. This is the only notice; no other copies of this notice will be provided.","html":"Page 2 of 3\n\nTHIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE.\n\nThe NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI 53214, is performing market research to determine if there is a sufficient number of qualified: (1) Service Disabled Veteran Owned Small Business (SDVOSB); (2) Veteran Owned Small Business (VOSB); or (3) Small or emerging small business firms, or (4) Other Than Small business firms, to provide Ceiling Lift for the Milwaukee VAMC.\n\nGeneral Requirements:\n\nSalient Characteristics:\ni. The Lift Unit shall be constructed of a steel frame system driven by a gear-reduced, high-torque, horizontal axis motor.\n1. The ceiling lift motor shall have an integrated Class III scale that allows users to read weights off the hand control.\n2. 2 lifts with minimum 770 lbs weight capacity\na. Weight capacity shall be achieved using a single lift motor\n3. Electronic soft-start and soft-stop motor control.\n4. Shall have an emergency manual lowering device. This emergency manual lowering device cord shall be red. Operation of the emergency manual lowering device shall be in such a way that users can apply continuous pull to the cord to facilitate slow descent of the patient.\n5. Emergency stopping device.\n6. Current limiter for circuit protection in case of overload.\n7. Safety device that stops the motor to lift when batteries are low.\n8. Emergency brake (in case of mechanical failure).\n9. Hanger bar shall be able to reach the floor.\n10. Cab: VO plastic fire retardant, UL 94.\n11. Hand controller shall be able to be stored securely to the hanger bar.\n12. The safe working load of the ceiling lift motor shall be clearly labeled on the outside of the ceiling lift motor.\n13. The life cycle (number of charging cycles) for batteries shall comply with IEC 6100-1-2.\n14. Provide rechargeable batteries with up to 120 transfers with a load of 200lbs (74kg) (for repositioning)\n15. The ceiling lift system (motor/hanger assembly) shall be approved for use with Guldmann Repositioning, High Back, Twin Turner and Limb Lifter loop slings.\nii. Two (2) Basic High Slings:\n1. The straps shall meet ISO 10535, Appendix A guidelines. The straps shall ensure the patient s safety by preventing the patient from falling out of the sling.\n2. The sling shall meet ISO 10535, Appendix A guidelines. The sling shall cradle the body of the patient. Bariatric slings shall be rated to a minimum of 770 lbs.\niii. Two (2) Hanger Bars: The hanger bar style shall be the four (4) suspension point style compatible with the lift strap.\niv. Continuous charge track systems\n1. Two (2) Double Rail continuous charge track systems with bathroom access\n2. The Ceiling Track shall be made from high strength extruded aluminum. Provide anchor supports at ceiling substrate\n3. Installed rail shall be security tested for 1.5 times greater than the motor s weight capacity and maximum allowable deflection of a horizontal rail is no more than 1/16th inch per 7.87 inch of track length per ISO 10535 standards.\n\n\nAll interested firms who can meet the requirements stated above should respond, in writing,\nINCLUDING ALL THE FOLLOWING:\nCompany name.\nAddress.\nPoint of contact (name/title/telephone number/e-mail address).\nFSS / SEWP Contract number, if applicable.\nSAM Unique ID number.\nTax ID number.\nIndication of which business category (SDVOSB, VOSB, Small Business or Other Than Small Business) for which the organization qualifies.\nA capability statement that addresses the organizations qualifications and ability to provide the requirement depicted above.\nDocumentation from manufacturer (i.e. correspondence from manufacturer) of your firm being an authorized distributor for the manufacturer.\nLocation of Manufacturer\n\n\nSubmit responses to the Contracting Specialist, Matthew Hohl, at Matthew.Hohl@va.gov no later than 11:59 PM (Central Standard Time), July 21st  2026.\n\n36C25226Q0596 Ceiling lift-3215 shall be referenced on all correspondence regarding this announcement.\n\nTELEPHONIC INQUIRIES WILL NOT BE ACCEPTED.\n\nThe NAICS Code 339112, Surgical and Medical Instrument Manufacturing, is applicable to this acquisition; the size standard is 1,000 employees. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Systems for Award Management (SAM) database prior to award of a contract. The Government will use responses to this notice to make an appropriate acquisition decision. This is the only notice; no other copies of this notice will be provided.","origin":"detail"},"contacts":[{"name":"Matthew Hohl","role":"primary","email":"Matthew.hohl@va.gov","phone":"Matthew.hohl@va.gov","title":"Contracting Officer"}],"place_of_performance":{"street":"Milwaukee VA 53295"},"office_address":{"zip":"53214","city":"MILWAUKEE","state":"WI","country":"USA"},"naics_codes":["339112"],"award":{"awardee":{}},"attachments":[{"resource_id":"cb4e164f6c5445f6843b6f350e98a926","name":"36C25226Q0596.docx","kind":"file","mime_type":".docx","size_bytes":26499,"posted_at":"2026-07-13T13:13:53.905Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/cb4e164f6c5445f6843b6f350e98a926/download","mirrored":false}],"awards":[],"related":[{"key":"36C25227Q0069","latest_notice_id":"a5df97556f82467697efcb6068ceecce","title":"S222--Grease Trap Service-FY27 Base-Tomah VAMC - December 2026 - November 2027","solicitation_number":"36C25227Q0069","notice_type":"o","first_type":"p","first_posted":"2026-11-04","last_posted":"2026-11-25","notices":4,"due_at":"2026-11-27T16:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"562998","psc":"S222","set_aside":"SBA","state":"WI","county":"55081","county_name":"Monroe County","city":"5580075","city_name":"Tomah","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Tomah VA Medical Center","site_key":"tomah-va-medical-center-wi","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"},{"key":"36C25227Q0033","latest_notice_id":"4d3caf6262ae49649e71c4eadbda1187","title":"Q702--Great Lakes Region Durable Medical Equipment (DME) Delivery Services","solicitation_number":"36C25227Q0033","notice_type":"o","first_type":"o","first_posted":"2026-11-06","last_posted":"2026-11-19","notices":3,"due_at":"2026-11-30T12:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T12:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"621610","psc":"Q702","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C25227B00020001","latest_notice_id":"7eafb50009534028818a8ee9836b9e30","title":"Z1DA--550-20-121 Demo Old Boiler Plant B100 (CON)","solicitation_number":"36C25227B0002-0001","notice_type":"o","first_type":"o","first_posted":"2026-10-21","last_posted":"2026-11-10","notices":2,"due_at":"2026-12-02T19:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"IL","county":"17183","county_name":"Vermilion County","city":"1718563","city_name":"Danville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"36C25227Q0059","latest_notice_id":"356844aa4dfe401da0c9186aa3e03e85","title":"4130--Chiller Compressor Replacement at the Edward Hines Jr. VA Hospital (Hines) Building 228","solicitation_number":"36C25227Q0059","notice_type":"o","first_type":"r","first_posted":"2026-10-16","last_posted":"2026-11-16","notices":2,"due_at":"2026-12-03T16:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"238220","psc":"J043","set_aside":"SDVOSBC","state":"IL","county":"17031","county_name":"Cook County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C25227B0006","latest_notice_id":"e4fa6ced73cf448f9259359ef2b8eeab","title":"Z1DA--537-26-101 Construction of Ogden Elevator Cab Interiors Jesse Brown VA Medical Center","solicitation_number":"36C25227B0006","notice_type":"p","first_type":"p","first_posted":"2026-10-20","last_posted":"2026-10-20","notices":1,"due_at":"2026-12-04T16:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"238290","psc":"Z1DA","set_aside":"SDVOSBC","state":"IL","county":"17031","county_name":"Cook County","city":"1714000","city_name":"Chicago","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":"Jesse Brown VA Medical Center","site_key":"jesse-brown-va-medical-center-il","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-21T04:57:30.751375Z"}],"similar_open":[{"key":"W911S227U0200","latest_notice_id":"153aef7d00e740188276deb8422a2297","title":"Automated External Defibrillator (AED)","solicitation_number":"W911S227U0200","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T20:15:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:15:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C10X27Q0025","latest_notice_id":"8c404062fbbc4212bb93120ad204ee50","title":"6515--NX EQ Microscope, Light, Operating, Hand/Plastic Surgery (VA-27-00017958)","solicitation_number":"36C10X27Q0025","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"SPE2DS27T2443","latest_notice_id":"8f83cd5d4eb6487083e3a8ace6f5842d","title":"65--TEST KIT,MICRO SAMPLE","solicitation_number":"SPE2DS27T2443","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":null,"due_date":"2026-11-30","closes_at":"2026-12-01T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE2DS","office_name":"DLA TROOP SUPPORT","naics":"339112","psc":"65","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"SAMPLE: LINE 0001 QTY 4 UI EA DELIVER TO: AMC BAMC FSH - MM BY:","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"}],"similar_open_total":15,"indexable":false}