{"canonical":"https://sealedbidder.com/opportunities/36c25226q0314","key":"36C25226Q0314","url":"https://sealedbidder.com/opportunities/36c25226q0314","title":"H339--Madison Elevator Inspection/ Base plus four (Base Year)","solicitation_number":"36C25226Q0314","notice_type":"a","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-03-13T15:00:00Z","first_posted":"2026-03-04","last_posted":"2026-04-26","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"541350","psc":"H339","set_aside":"SDVOSBC","place_state":"WI","place_scope":"site","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"55025","place_county_name":"Dane County","place_city":"5548000","place_city_name":"Madison","winner":"VETERAN ELEVATOR INSPECTION SERVICES, LLC","award_amount":"9785.00","publications":[{"notice_id":"503792f4938a4706b2aef95466bb92af","title":"H339--NEW Madison, WI VAMC Elevator Inspection Services","solicitation_number":"36C25226Q0314","notice_type":"r","base_type":"r","posted":"2026-03-04","posted_at":"2026-03-04T15:50:42.997Z","due_at":"2026-03-13T15:00:00Z","due_date":"2026-03-13","cancelled":false,"archived":true,"archive_date":"2026-04-02","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/503792f4938a4706b2aef95466bb92af/view","enriched":true,"history":[{"index":3,"title":"H339--NEW Madison, WI VAMC Elevator Inspection Services","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-04T15:50:42.997Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"503792f4938a4706b2aef95466bb92af","solicitation_number":"36C25226Q0314"}]},{"notice_id":"12927ab81d2c4072a5eeee7bb23eac17","title":"H339--Madison Elevator Inspection/ Base plus four (Base Year)","solicitation_number":"36C25226Q0314","notice_type":"a","base_type":"a","posted":"2026-04-26","posted_at":"2026-04-26T16:24:20.217Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-05-26","removed_at":null,"award_number":"36C25226P0323","awardee_name":"Veteran Elevator Inspection Services, LLC","amount":"9785.00","link_sam":"https://sam.gov/workspace/contract/opp/12927ab81d2c4072a5eeee7bb23eac17/view","enriched":true,"history":[{"index":3,"title":"H339--Madison Elevator Inspection/ Base plus four (Base Year)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-26T16:24:20.217Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"12927ab81d2c4072a5eeee7bb23eac17","solicitation_number":"36C25226Q0314"}]}],"latest_notice_id":"12927ab81d2c4072a5eeee7bb23eac17","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-03-04","posted_at":"2026-03-04T15:50:42.997Z","created_at":"2026-03-04T15:50:40.800Z","modified_at":"2026-04-03T03:55:45.190Z","response_deadline":{"raw":"2026-03-13T10:00:00-05:00","utc":"2026-03-13T15:00:00Z","date":"2026-03-13","time":"10:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/503792f4938a4706b2aef95466bb92af/view"},"naics":{"codes":["541350"],"primary":"541350"},"title":"H339--NEW Madison, WI VAMC Elevator Inspection Services","agency":{"office":{"code":"36C252","name":"252-NETWORK CONTRACT OFFICE 12 (36C252)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"53214","city":"MILWAUKEE","state":"WI","country":"USA"},"organization_id":"100180018","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-04-02","archive_type":"auto_custom"},"history":[{"index":3,"title":"H339--NEW Madison, WI VAMC Elevator Inspection Services","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-04T15:50:42.997Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"503792f4938a4706b2aef95466bb92af","solicitation_number":"36C25226Q0314"}],"contacts":[{"name":"Makena James","role":"primary","email":"Makena.James@va.gov","phone":"(414) 844-4871","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"503792f4938a4706b2aef95466bb92af","lineage_id":"503792f4938a4706b2aef95466bb92af","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-12T00:21:35.902616714Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"e199636dad5b23791fee718631ddbee5313e643957f2b4a94914d6a0b0c4ba3f","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-12T00:21:35.902616714Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"The Department of Veterans Affairs, Great Lakes Acquisition Center (GLAC) is searching for \nvendors with the capabilities to furnish all supervision, labor, equipment, travel and supplies necessary to perform Semi-Annual periodic routine elevator dumbwaiter inspections, perform Annual Category 1 elevator dumbwaiter periodic inspection and safety tests and the Five Year Load Test of elevators and dumbwaiters located at the at the William S. Middleton Memorial Veterans Hospital, 2500 Overlook Terrace, Madison, WI 53705. This will be a base plus four contract. Firm-fixed price. \n\nThe Contractor shall provide all personnel, equipment, material, parts, software, supplies, \nfacilities, transportation, tools, materials, supervision, and other items and non-personal services necessary for execution of the work to be performed under this Contract. \nThe North American Industry Classification System (NAICS) code for this procurement is \n541350. \n\nAll interested, responsible sources must submit a capability statement by March 13th, \n2026 at 10:00 AM CST, to Makena.James@VA.gov to include the following: \nDUNS number, organization name, organization address, point of contact, business size \nunder NAICS 541350, and socioeconomic status. \n\nThis Sources Sought is issued solely for information and planning purposes to determine the availability of qualified vendors and does not constitute a solicitation. All information received in response to this Sources Sought that is marked as proprietary will be handled accordingly. \nPlease note that this is not a request for proposal and the Government is seeking information for market research purposes only. The Government may or may not issue solicitation documents. Please Look for any further information in Contract Opportunities. \nTelephone inquiries will not be returned.\n\n\n\n\n\n\nSTATEMENT OF WORK  \n\nFurnish all supervision, labor, equipment, travel and supplies necessary to perform Semi-Annual periodic routine elevator dumbwaiter inspections, perform Annual Category 1 elevator dumbwaiter periodic inspection and safety tests and the Five Year Load Test of elevators and dumbwaiters located at the at the William S. Middleton Memorial Veterans Hospital, 2500 Overlook Terrace, Madison, WI 53705.\n\n1. BACKGROUND AND OBJECTIVES:  Madison VAH requires two complete periodic routine elevator inspections per year per all ASME codes.   Periodic routine elevator inspections include the witness and certification of one (1) Semi-Annual periodic routine elevator /dumbwaiter inspection, one (1) Annual Category 1 periodic elevator/dumbwaiter inspection and safety tests per all ASME codes and the witness of one (1) Five Year Load Test of all of the elevators and dumbwaiters. \n2. REQUIREMENTS AND QUALIFICATIO NS OF ELEVATOR, DUMBWAITER and LIFT INSPECTORS:  The inspectors and inspection supervisor shall meet the qualification requirements of the ASME QEI-1. Inspectors and inspection supervisors shall be certified by an organization accredited by ASME in accordance with the requirements of ASME QEI-1.  All work performed under this contract shall be accomplished by a QEI-1 certified inspector employed on a permanent basis by the Contractor awarded this contract.  The inspectors  supervisor shall also be QEI-1 qualified.  The inspector and inspection supervisor shall be employed on a permanent basis by the Contractor awarded this contract.  The contractor must provide proof of QEI-1 certification for their inspectors and supervisors.  Copies of the QEI-1 inspectors and supervisor s certificates shall be provided with the proposal.\n  \n3. INSPECTIONS:  There shall be two (2) inspections per year, every six months, on all the equipment listed in the Schedule of Elevators and Dumbwaiters. Inspections include a Semi-Annual periodic routine elevator, dumbwaiter and lift inspection and the Annual Category 1 elevator, dumbwaiter and lift periodic inspection and annual safety test inspection.  Inspections shall include but are not limited to; inside of the cars, elevator machine rooms and equipment, elevator control room and equipment, secondary equipment and machine rooms, tops of cars, hoist ways, shafts, elevator lobbies and elevator pits.  \nAll inspections shall be conducted in accordance with the latest editions of ASME A17.1 \nand all current elevator requirements and standards. Inspections shall cover all items as stated in ASME 17.1, Section 8.11.\nInspections shall follow the recommended inspection and test intervals as specified in latest edition of Table N-1 of the ASME A17.1, Safety Code for Elevators.  \nAll inspections and tests shall be in accordance with the latest editions of other applicable codes, such as, but not limited to: \nASME A17.1/CSA B44 Safety Code for Elevators and Escalators   Current Edition\nASME A17.1 Safety Code for Elevators and escalators   Current Edition\nASME A17.2 Guide for Inspection of Elevators, Escalators and Moving Walks   Current Edition\nASME A17.3 Safety Code for Existing Elevator and Escalators. \nASME A17.4 Guide for Emergency Evacuation of Passenger from Elevators.\n\n3.1  One (1) site visit/inspection per year, preferred at the first calendar year inspection, shall include, in addition to all required inspections and safety tests, a review of the existing equipment for safety code compliance, including the firefighters' service functions, ADA requirements, as well as recommended upgrades, enhancements or modernization or needs based on long term life expectancy of the current existing equipment.  These findings and recommendations shall be submitted in a separate narrative and included with the inspection report. \n3.2  During any inspection, parts shall be removed where necessary to determine the exact condition of parts which could not otherwise be determined, and the equipment shall be cleaned where necessary to make the proper inspection. All parts shall he reinstalled after removal.  Elevator inspector shall provide all necessary tools; door pressure gauge, stopwatch, calipers, flashlight and any other small hand tools necessary to conduct inspections.\n\n3.3  All inspections shall be performed in the presence of the elevator maintenance technician, currently under contract as the VA elevator preventative maintenance contractor and a representative from the VA Hospital.  The COR at the medical center shall accompany the contractor as an observer, if they choose, during the time of the inspections.  \n\n3.4  First inspection shall be within 60 days after contract award.  Second inspection shall be 6 months later.  All subsequent inspections in the following option years shall be on the same twice per year schedule. \n3.5  Each site visit/inspection shall include an out brief meeting with the COR or VA Rep to discuss the inspection violations, findings, immediate needs, and necessary corrections. \n3.6  In addition to using the standards in the A17.1 and A17.2 Codes, the inspection contractor shall assure that the maintenance contractor s preventative maintenance check charts are up to date and correctly annotated. \n\n3.7  Base Year requirement:  Provide to the VA,  the latest edition of ASME A17.4 Guide for Emergency Evacuation of Passengers from Elevators. Provide code book with the first base year report.\n4. ANNUAL / SEMI-ANNUAL TEST: The elevator inspector shall be on site to witness and certify the Annual Category 1 safety tests performed with the VA elevator maintenance contractor.  Elevator safeties shall be subjected to the annual running tests as required by ASME A17.2 latest edition. The Annual Category 1 safety tests and inspection will be scheduled to concur with one of the required bi-annual inspections.  The elevator inspector shall be on site to witness and certify the Semi-Annual inspections and tests and cover all items as specified in the latest editions of ASME A17.2.  \n4.1 PERFORMANCE EVALUATION DATA:  In addition to the required ASME Annual & Semi-Annual inspections.  The Inspection Contractor shall provide an elevator performance evaluation in report form for all elevators, dumbwaiters and lifts once per year.  \n5. FIVE-YEAR INSPECTION AND LOAD TEST:  The elevator inspector shall be on site to witness and certify the five-year load & safety tests performed by the VA elevator maintenance contractor.  The five-year inspection and load tests are performed during off tour hours, between 5:00pm on a Friday and 7:00am on Monday.  The Contractor shall be notified in advance by the COR on date and times of the Five  Year Inspection & Test.  It is anticipated that the five-year load & safety tests will occur in Base Year (2026) of this contract.  The five-year inspection and load tests shall be performed during a weekend or holiday to reduce the impact to the facility. \n 6. DOCUMENTATION:  Each inspection survey/evaluation shall include a comprehensive narrative/report.  The narrative/report shall include:\n6.1 Listing and narrative of the operating performance for each elevator/lift. \n6.2 A narrative, which summarizes the inspection and tests conducted.  \n6.3 Explains and identifies any conditions found to exist, that require repair or replacement. \n6.4 Provide recommendations as to what actions should be implemented to correct deficiencies and/or conditions identified. \n 6.5 Provide list of typical parts that are needed and are recommended for replacement to keep the equipment in good operating condition. \n6.6 Contractor shall if necessary, clearly indicate any adjustments, repairs, or replacements necessary to correct troubles encountered.  \n6.7 Shall furnish specifications (if requested by the COR) enough to enable the VA to purchase the materials required for those purposes.  \n6.8 Indicate all items and locations inspected.\n6.9 A narrative of all findings and recommendations of the existing equipment as detailed in paragraph 3.1.  Narrative and recommendations listed above shall be in addition to standard ASME report/checklists and reports per the required ASME codes.  \n6.10 Reports shall be submitted electronically to the VA COR and the VA CO within two (2) weeks after completion of the inspection.  \n\n6.11 Provide the latest edition of ASME A17.4 Guide for Emergency Evacuation of Passengers from Elevators code book along with the base year report.\n\n7. RECOGNIZED HOLIDAYS:   Unless otherwise indicated, the contractor is not required to perform services on these Federal holidays.      \nNew Year s Day     Labor Day\nMartin Luther King Jr. Day    Columbus Day\nPresidents  Day     Veterans Day\nMemorial Day      Thanksgiving Day\nJuneteenth       Christmas Day    \nIndependence Day     \n\n8. HOURS OF OPERATION:  Unless otherwise indicated (such as five-year load test), the contractor is responsible for conducting business, between the hours of 7:00AM and 5:00PM Monday thru Friday except Federal holidays or when the Government facility is closed due to local or national emergencies, administrative closings, or similar Government directed facility closings.  \n9. PLACE OF PERFORMANCE:  The work to be performed under this contract will be performed at the following government facility: \nWilliam S. Middleton Memorial Veterans Hospital  \n2500 Overlook Terrace     \nMadison, WI  53705-2286  \n\n10. SECURITY REQUIREMENTS:  Contractor personnel performing work under this contract must check in with the VA Contracting Officer Representative and shall be escorted by the VA COR or VA rep and the VA elevator maintenance technician during all elevator inspections.\n11. INTERFERENCE TO NORMAL FUNCTION:  Contractor personnel are required to interrupt their work at any time so as not to interfere with the normal functioning of the facility, including utility services, fire protection systems, and passage of patients, personnel, equipment, and carts.\n\n12. SAFETY:  The Contractor shall consider the clinical environment and instruct his/her employees on applicable safety precautions and specific requirements. \nContractor shall comply with OSHA General Industry and Construction Standards (29 CFR 1910 and 29 CFR 1926.  Contractor to provide an OSHA 10 Hour General Industry Training certificate. \nThe contractor is responsible for compliance with all OSHA and other applicable safety regulations.  Contractor is required to protect the immediate safety of persons and equipment in and about the elevator(s) during the inspection process.  \n\n13.  ACRONYMS/DEFINITIONS:\nCO - Contracting Officer\nCOR - Contracting Officer's Representative\nVAH - Department of Veterans Affairs Hospital\nHIPPA- Health Insurance Portability and Accountability Act\n\n14. IDENTIFICATION, PARKING, SMOKING, AND VA REGULATIONS (For any onsite services): \n1.  The Contractor's employees and/or subcontractors approved by the COR shall wear visible identification at all time while on the premises of the VAH.  Identification shall include, but not be limited to a company identification card, which shall include the company name, employee name, title, and a photograph of the employee. \n\n2.  It is the responsibility of the Contractor to park in the appropriate designated parking areas.  Information on parking is available from the VAH Police Section.  The VAH will not invalidate or make reimbursement for parking violations of the Contractor under any conditions.  \n  \n3.  Any interior or exterior doors that shall be unlocked to gain access shall be kept locked during the performance of work unless it results in the creation of a safety hazard.  In those instances, the Contractor is responsible to take necessary actions to maintain the same level of security prior to gaining access/performing work.  Should any other devices need to be unlocked like an entry gate, those devices shall be locked immediately upon entry or exit.  At no time shall the Contractor allow any person into a locked area or loan keys/access cards to another person.  Contractor may be held in default for failure to comply with this requirement and subject the Contractor and employees to contract and other legal remedies.\n\n4.  The Contractor agrees that none of its officers or employees shall use or reveal any research, statistical, medical, or security information which may be obtained during the performance of the work or as a result their presence on Government premises without the written consent of the Government.\n \n5.  Smoking is prohibited inside any buildings at the VAH.\n\n6.  Possession of weapons is prohibited.\n\n7.  Enclosed containers, including tool kits, may be subject to search.  Violations of VA regulations may result in citation answerable in the United States (Federal) District Court, not a local district, state, or municipal court.   \n\n\n\n\n\nSchedule of Elevators, Dumbwaiters and Lifts\nLOCATION          ELEVATOR #               MANUFACTURER       STOPS        SYSTEM TYPE\n \nBLDG. 1, B-WING PASSENGER P1  SCHUMACHER            9        GEARLESS TRACTION\n\nBLDG. 1, B-WING PASSENGER P2  SCHUMACHER            9        GEARLESS TRACTION\n\nBLDG. 1, B-WING PASSENGER P3  SCHUMACHER            9         GEARLESS TRACTION\n\nBLDG. 1, B-WING PASSENGER P4  SCHUMACHER            9         GEARLESS TRACTION\n\nBLDG. 1, B-WING          FREIGHT S5   SCHUMACHER          10         GEARLESS TRACTION\n\nBLDG. 1, C-WING          FREIGHT S6                SCHUMACHER 5         GEARLESS TRACTION\n\nBLDG. 1, D-WING MORGUE   SCHUMACHER            2         HYDRAULIC  \n\nBLDG. 1, D-WING         PASSENGER P8  SCHUMACHER          10        GEARLESS TRACTION\n\nBLDG. 1, D-WING PASSENGER P9            SCHUMACHER          10       GEARLESS TRACTION\n\nBLDG. 1, D-WING PASSENGER P10        SCHUMACHER           10      GEARLESS TRACTION\n\nBLDG. 1, D-WING MATL/CART LIFT 1  MATOT   2         TRACTION \n\nBLDG. 1, D-WING DUMBWAITER  LAB  MATOT  2         TRACTION\n\nBLDG. 15  PASSENGER P1  THYSSENKRUPP 6          HYDRAULIC\n \nBLDG. 15  PASSENGER P2  THYSSENKRUPP 6          HYDRAULIC\n\nBLDG. 16                       PASSENGER P1            SCHUMACHER            5          HYDRAULIC\n       \nBLDG. 22  PASSENGER P1   SCHUMACHER 3          HYDRAULIC\n\nBLDG. 2          PASSENGER P1  SCHUMACHER 3          HYDRAULIC\n\nBLDG. 6  PASSENGER P1           SCHUMACHER 2          HYDRAULIC\n\nBLDG. 2          SERVICE S1   SCHUMACHER 3         HYDRAULIC\n\n\n\n\n\n\n\n\n\n\n\n\nSUPPLIES OR SERVICES AND PRICES/COSTS\n\nFurnish all supervision, labor, equipment, travel and supplies necessary to perform Semi-Annual periodic routine elevator dumbwaiter inspections, perform Annual Category 1 elevator dumbwaiter periodic inspection and safety tests and one (1) Five Year Load Test of elevators located at the William S. Middleton Memorial Veterans Hospital, 2500 Overlook Terrace, Madison, WI 53705.\n\nBASE PERIOD: July 1, 2026, through June 30, 2027\nCLIN       Description                       QTY          Unit        Unit Price                   Total Price\n0001    Semi-Annual Periodic             19            EA            $____             $___\n             Routine Elevator/Dumbwaiter \nInspections as per \nStatement of Work\n\n0002   Annual Category 1                      19           EA              $______        $____\n Elevator/Dumbwaiter\nPeriodic Inspection\nand Annual Safety Tests\n per Statement of Work \n                                                        \n2003 Five Year Load Test to be         1              EA                $_______     $____\n Performed on Elevators\n per Statement of Work and \nSchedule below: \n\nFive Year Load Test Elevator Schedule (Base Year) \n\nLOCATION          ELEVATOR #               MANUFACTURER       STOP         SYSTEM TYPE\n \nBLDG. 1, B-WING PASSENGER P-1  SCHUMACHER            9        GEARLESS TRACTION\n\nBLDG. 1, B-WING PASSENGER P-2  SCHUMACHER            9        GEARLESS TRACTION\n\nBLDG. 1, B-WING PASSENGER P-3  SCHUMACHER            9         GEARLESS TRACTION\n\nBLDG. 1, B-WING PASSENGER P-4  SCHUMACHER            9         GEARLESS TRACTION\n\nBLDG. 1, B-WING          FREIGHT 5   SCHUMACHER          10         GEARLESS TRACTION\n\nBLDG. 1, C-WING          FREIGHT 6                   SCHUMACHER           4          GEARLESS TRACTION\n\nBLDG. 1, D-WING         MORGUE                       SCHUMACHER            10         HYDRAULIC\n\nBLDG. 1, D-WING         PASSENGER P-8          SCHUMACHER            10         GEARLESS TRACTION\n\nBLDG. 1, D-WING         PASSENGER P-9          SCHUMACHER            10         GEARLESS TRACTION\n\nBLDG. 1, D-WING         PASSENGER P-10        SCHUMACHER            10         GEARLESS TRACTION\n\nBLDG. 22  PASSENGER P-1   SCHUMACHER 3           HYDRAULIC\n\nBLDG. 2          PASSENGER P-1  SCHUMACHER 3 HYDRAULIC\n\nBLDG. 6  PASSENGER P-1           SCHUMACHER 2 HYDRAULIC\n                                                                                                                                                                                        \n\n \n\nTotal BASE PERIOD: $__________\n\n\nOPTION YEAR 1: July 1, 2027, through June 30, 2028 \nCLIN       Description                        QTY          Unit               Unit Price                Total Price\n1001    Semi-Annual Periodic             19            EA            $____             $___\n             Routine Elevator/Dumbwaiter \nInspections per \nStatement of Work\n\n1002   Annual Category 1                      19          EA              $______        $____\n Elevator/Dumbwaiter\nPeriodic Inspection\nand Annual Safety Tests\n per Statement of Work \n\n                                                         Total OPTION YEAR 1: $_____________\n\n\n\n\n\n\n\n\n\nOPTION YEAR 2: July 1, 2028, through June 30, 2029\nCLIN       Description                       QTY          Unit                   Unit Price                Total Price\n2001    Semi-Annual Periodic             19             EA            $____             $___\n             Routine Elevator/Dumbwaiter \nInspections per \nStatement of Work\n\n2002   Annual Category 1                      19          EA              $______        $____\n Elevator/Dumbwaiter\nPeriodic Inspection\nand Annual Safety Tests\n per Statement of Work \n\n\n                                                         Total OPTION YEAR 2: $____________\n\n\n\n\nOPTION YEAR 3: July 1, 2029, through June 30, 2030\nCLIN       Description                      QTY          Unit            Unit Price                Total Price\n3001    Semi-Annual Periodic             19            EA            $____             $___\n             Routine Elevator/Dumbwaiter \nInspections per \nStatement of Work\n\n3002  Annual Category 1                      19          EA              $______        $____\n Elevator/Dumbwaiter\nPeriodic Inspection\nand Annual Safety Tests\n per Statement of Work \n\n                                                         Total OPTION YEAR 3: $______________\n\n\n\n\n\nOPTION YEAR 4: July 1, 2030, through June 30, 2031\nCLIN       Description                      QTY          Unit                Unit Price                Total Price\n4001    Semi-Annual Periodic             19          EA            $____             $___\n             Routine Elevator/Dumbwaiter \nInspections per \nStatement of Work\n\n4002  Annual Category 1                      19           EA              $______        $____\n Elevator/Dumbwaiter\nPeriodic Inspection\nand Annual Safety Tests\n per Statement of Work \n\n                                                        Total OPTION YEAR 4: $_____________\n\n\n\nTOTAL for BASE and ALL OPTION YEARS:  $_________________","text":"The Department of Veterans Affairs, Great Lakes Acquisition Center (GLAC) is searching for\nvendors with the capabilities to furnish all supervision, labor, equipment, travel and supplies necessary to perform Semi-Annual periodic routine elevator dumbwaiter inspections, perform Annual Category 1 elevator dumbwaiter periodic inspection and safety tests and the Five Year Load Test of elevators and dumbwaiters located at the at the William S. Middleton Memorial Veterans Hospital, 2500 Overlook Terrace, Madison, WI 53705. This will be a base plus four contract. Firm-fixed price.\n\nThe Contractor shall provide all personnel, equipment, material, parts, software, supplies,\nfacilities, transportation, tools, materials, supervision, and other items and non-personal services necessary for execution of the work to be performed under this Contract.\nThe North American Industry Classification System (NAICS) code for this procurement is\n541350.\n\nAll interested, responsible sources must submit a capability statement by March 13th,\n2026 at 10:00 AM CST, to Makena.James@VA.gov to include the following:\nDUNS number, organization name, organization address, point of contact, business size\nunder NAICS 541350, and socioeconomic status.\n\nThis Sources Sought is issued solely for information and planning purposes to determine the availability of qualified vendors and does not constitute a solicitation. All information received in response to this Sources Sought that is marked as proprietary will be handled accordingly.\nPlease note that this is not a request for proposal and the Government is seeking information for market research purposes only. The Government may or may not issue solicitation documents. Please Look for any further information in Contract Opportunities.\nTelephone inquiries will not be returned.\n\nSTATEMENT OF WORK\n\nFurnish all supervision, labor, equipment, travel and supplies necessary to perform Semi-Annual periodic routine elevator dumbwaiter inspections, perform Annual Category 1 elevator dumbwaiter periodic inspection and safety tests and the Five Year Load Test of elevators and dumbwaiters located at the at the William S. Middleton Memorial Veterans Hospital, 2500 Overlook Terrace, Madison, WI 53705.\n\n1. BACKGROUND AND OBJECTIVES: Madison VAH requires two complete periodic routine elevator inspections per year per all ASME codes. Periodic routine elevator inspections include the witness and certification of one (1) Semi-Annual periodic routine elevator /dumbwaiter inspection, one (1) Annual Category 1 periodic elevator/dumbwaiter inspection and safety tests per all ASME codes and the witness of one (1) Five Year Load Test of all of the elevators and dumbwaiters.\n2. REQUIREMENTS AND QUALIFICATIO NS OF ELEVATOR, DUMBWAITER and LIFT INSPECTORS: The inspectors and inspection supervisor shall meet the qualification requirements of the ASME QEI-1. Inspectors and inspection supervisors shall be certified by an organization accredited by ASME in accordance with the requirements of ASME QEI-1. All work performed under this contract shall be accomplished by a QEI-1 certified inspector employed on a permanent basis by the Contractor awarded this contract. The inspectors supervisor shall also be QEI-1 qualified. The inspector and inspection supervisor shall be employed on a permanent basis by the Contractor awarded this contract. The contractor must provide proof of QEI-1 certification for their inspectors and supervisors. Copies of the QEI-1 inspectors and supervisor s certificates shall be provided with the proposal.\n\n3. INSPECTIONS: There shall be two (2) inspections per year, every six months, on all the equipment listed in the Schedule of Elevators and Dumbwaiters. Inspections include a Semi-Annual periodic routine elevator, dumbwaiter and lift inspection and the Annual Category 1 elevator, dumbwaiter and lift periodic inspection and annual safety test inspection. Inspections shall include but are not limited to; inside of the cars, elevator machine rooms and equipment, elevator control room and equipment, secondary equipment and machine rooms, tops of cars, hoist ways, shafts, elevator lobbies and elevator pits.\nAll inspections shall be conducted in accordance with the latest editions of ASME A17.1\nand all current elevator requirements and standards. Inspections shall cover all items as stated in ASME 17.1, Section 8.11.\nInspections shall follow the recommended inspection and test intervals as specified in latest edition of Table N-1 of the ASME A17.1, Safety Code for Elevators.\nAll inspections and tests shall be in accordance with the latest editions of other applicable codes, such as, but not limited to:\nASME A17.1/CSA B44 Safety Code for Elevators and Escalators Current Edition\nASME A17.1 Safety Code for Elevators and escalators Current Edition\nASME A17.2 Guide for Inspection of Elevators, Escalators and Moving Walks Current Edition\nASME A17.3 Safety Code for Existing Elevator and Escalators.\nASME A17.4 Guide for Emergency Evacuation of Passenger from Elevators.\n\n3.1 One (1) site visit/inspection per year, preferred at the first calendar year inspection, shall include, in addition to all required inspections and safety tests, a review of the existing equipment for safety code compliance, including the firefighters' service functions, ADA requirements, as well as recommended upgrades, enhancements or modernization or needs based on long term life expectancy of the current existing equipment. These findings and recommendations shall be submitted in a separate narrative and included with the inspection report.\n3.2 During any inspection, parts shall be removed where necessary to determine the exact condition of parts which could not otherwise be determined, and the equipment shall be cleaned where necessary to make the proper inspection. All parts shall he reinstalled after removal. Elevator inspector shall provide all necessary tools; door pressure gauge, stopwatch, calipers, flashlight and any other small hand tools necessary to conduct inspections.\n\n3.3 All inspections shall be performed in the presence of the elevator maintenance technician, currently under contract as the VA elevator preventative maintenance contractor and a representative from the VA Hospital. The COR at the medical center shall accompany the contractor as an observer, if they choose, during the time of the inspections.\n\n3.4 First inspection shall be within 60 days after contract award. Second inspection shall be 6 months later. All subsequent inspections in the following option years shall be on the same twice per year schedule.\n3.5 Each site visit/inspection shall include an out brief meeting with the COR or VA Rep to discuss the inspection violations, findings, immediate needs, and necessary corrections.\n3.6 In addition to using the standards in the A17.1 and A17.2 Codes, the inspection contractor shall assure that the maintenance contractor s preventative maintenance check charts are up to date and correctly annotated.\n\n3.7 Base Year requirement: Provide to the VA, the latest edition of ASME A17.4 Guide for Emergency Evacuation of Passengers from Elevators. Provide code book with the first base year report.\n4. ANNUAL / SEMI-ANNUAL TEST: The elevator inspector shall be on site to witness and certify the Annual Category 1 safety tests performed with the VA elevator maintenance contractor. Elevator safeties shall be subjected to the annual running tests as required by ASME A17.2 latest edition. The Annual Category 1 safety tests and inspection will be scheduled to concur with one of the required bi-annual inspections. The elevator inspector shall be on site to witness and certify the Semi-Annual inspections and tests and cover all items as specified in the latest editions of ASME A17.2.\n4.1 PERFORMANCE EVALUATION DATA: In addition to the required ASME Annual & Semi-Annual inspections. The Inspection Contractor shall provide an elevator performance evaluation in report form for all elevators, dumbwaiters and lifts once per year.\n5. FIVE-YEAR INSPECTION AND LOAD TEST: The elevator inspector shall be on site to witness and certify the five-year load & safety tests performed by the VA elevator maintenance contractor. The five-year inspection and load tests are performed during off tour hours, between 5:00pm on a Friday and 7:00am on Monday. The Contractor shall be notified in advance by the COR on date and times of the Five Year Inspection & Test. It is anticipated that the five-year load & safety tests will occur in Base Year (2026) of this contract. The five-year inspection and load tests shall be performed during a weekend or holiday to reduce the impact to the facility.\n6. DOCUMENTATION: Each inspection survey/evaluation shall include a comprehensive narrative/report. The narrative/report shall include:\n6.1 Listing and narrative of the operating performance for each elevator/lift.\n6.2 A narrative, which summarizes the inspection and tests conducted.\n6.3 Explains and identifies any conditions found to exist, that require repair or replacement.\n6.4 Provide recommendations as to what actions should be implemented to correct deficiencies and/or conditions identified.\n6.5 Provide list of typical parts that are needed and are recommended for replacement to keep the equipment in good operating condition.\n6.6 Contractor shall if necessary, clearly indicate any adjustments, repairs, or replacements necessary to correct troubles encountered.\n6.7 Shall furnish specifications (if requested by the COR) enough to enable the VA to purchase the materials required for those purposes.\n6.8 Indicate all items and locations inspected.\n6.9 A narrative of all findings and recommendations of the existing equipment as detailed in paragraph 3.1. Narrative and recommendations listed above shall be in addition to standard ASME report/checklists and reports per the required ASME codes.\n6.10 Reports shall be submitted electronically to the VA COR and the VA CO within two (2) weeks after completion of the inspection.\n\n6.11 Provide the latest edition of ASME A17.4 Guide for Emergency Evacuation of Passengers from Elevators code book along with the base year report.\n\n7. RECOGNIZED HOLIDAYS: Unless otherwise indicated, the contractor is not required to perform services on these Federal holidays.\nNew Year s Day Labor Day\nMartin Luther King Jr. Day Columbus Day\nPresidents Day Veterans Day\nMemorial Day Thanksgiving Day\nJuneteenth Christmas Day\nIndependence Day\n\n8. HOURS OF OPERATION: Unless otherwise indicated (such as five-year load test), the contractor is responsible for conducting business, between the hours of 7:00AM and 5:00PM Monday thru Friday except Federal holidays or when the Government facility is closed due to local or national emergencies, administrative closings, or similar Government directed facility closings.\n9. PLACE OF PERFORMANCE: The work to be performed under this contract will be performed at the following government facility:\nWilliam S. Middleton Memorial Veterans Hospital\n2500 Overlook Terrace\nMadison, WI 53705-2286\n\n10. SECURITY REQUIREMENTS: Contractor personnel performing work under this contract must check in with the VA Contracting Officer Representative and shall be escorted by the VA COR or VA rep and the VA elevator maintenance technician during all elevator inspections.\n11. INTERFERENCE TO NORMAL FUNCTION: Contractor personnel are required to interrupt their work at any time so as not to interfere with the normal functioning of the facility, including utility services, fire protection systems, and passage of patients, personnel, equipment, and carts.\n\n12. SAFETY: The Contractor shall consider the clinical environment and instruct his/her employees on applicable safety precautions and specific requirements.\nContractor shall comply with OSHA General Industry and Construction Standards (29 CFR 1910 and 29 CFR 1926. Contractor to provide an OSHA 10 Hour General Industry Training certificate.\nThe contractor is responsible for compliance with all OSHA and other applicable safety regulations. Contractor is required to protect the immediate safety of persons and equipment in and about the elevator(s) during the inspection process.\n\n13. ACRONYMS/DEFINITIONS:\nCO - Contracting Officer\nCOR - Contracting Officer's Representative\nVAH - Department of Veterans Affairs Hospital\nHIPPA- Health Insurance Portability and Accountability Act\n\n14. IDENTIFICATION, PARKING, SMOKING, AND VA REGULATIONS (For any onsite services):\n1. The Contractor's employees and/or subcontractors approved by the COR shall wear visible identification at all time while on the premises of the VAH. Identification shall include, but not be limited to a company identification card, which shall include the company name, employee name, title, and a photograph of the employee.\n\n2. It is the responsibility of the Contractor to park in the appropriate designated parking areas. Information on parking is available from the VAH Police Section. The VAH will not invalidate or make reimbursement for parking violations of the Contractor under any conditions.\n\n3. Any interior or exterior doors that shall be unlocked to gain access shall be kept locked during the performance of work unless it results in the creation of a safety hazard. In those instances, the Contractor is responsible to take necessary actions to maintain the same level of security prior to gaining access/performing work. Should any other devices need to be unlocked like an entry gate, those devices shall be locked immediately upon entry or exit. At no time shall the Contractor allow any person into a locked area or loan keys/access cards to another person. Contractor may be held in default for failure to comply with this requirement and subject the Contractor and employees to contract and other legal remedies.\n\n4. The Contractor agrees that none of its officers or employees shall use or reveal any research, statistical, medical, or security information which may be obtained during the performance of the work or as a result their presence on Government premises without the written consent of the Government.\n\n5. Smoking is prohibited inside any buildings at the VAH.\n\n6. Possession of weapons is prohibited.\n\n7. Enclosed containers, including tool kits, may be subject to search. Violations of VA regulations may result in citation answerable in the United States (Federal) District Court, not a local district, state, or municipal court.\n\nSchedule of Elevators, Dumbwaiters and Lifts\nLOCATION ELEVATOR # MANUFACTURER STOPS SYSTEM TYPE\n\nBLDG. 1, B-WING PASSENGER P1 SCHUMACHER 9 GEARLESS TRACTION\n\nBLDG. 1, B-WING PASSENGER P2 SCHUMACHER 9 GEARLESS TRACTION\n\nBLDG. 1, B-WING PASSENGER P3 SCHUMACHER 9 GEARLESS TRACTION\n\nBLDG. 1, B-WING PASSENGER P4 SCHUMACHER 9 GEARLESS TRACTION\n\nBLDG. 1, B-WING FREIGHT S5 SCHUMACHER 10 GEARLESS TRACTION\n\nBLDG. 1, C-WING FREIGHT S6 SCHUMACHER 5 GEARLESS TRACTION\n\nBLDG. 1, D-WING MORGUE SCHUMACHER 2 HYDRAULIC\n\nBLDG. 1, D-WING PASSENGER P8 SCHUMACHER 10 GEARLESS TRACTION\n\nBLDG. 1, D-WING PASSENGER P9 SCHUMACHER 10 GEARLESS TRACTION\n\nBLDG. 1, D-WING PASSENGER P10 SCHUMACHER 10 GEARLESS TRACTION\n\nBLDG. 1, D-WING MATL/CART LIFT 1 MATOT 2 TRACTION\n\nBLDG. 1, D-WING DUMBWAITER LAB MATOT 2 TRACTION\n\nBLDG. 15 PASSENGER P1 THYSSENKRUPP 6 HYDRAULIC\n\nBLDG. 15 PASSENGER P2 THYSSENKRUPP 6 HYDRAULIC\n\nBLDG. 16 PASSENGER P1 SCHUMACHER 5 HYDRAULIC\n\nBLDG. 22 PASSENGER P1 SCHUMACHER 3 HYDRAULIC\n\nBLDG. 2 PASSENGER P1 SCHUMACHER 3 HYDRAULIC\n\nBLDG. 6 PASSENGER P1 SCHUMACHER 2 HYDRAULIC\n\nBLDG. 2 SERVICE S1 SCHUMACHER 3 HYDRAULIC\n\nSUPPLIES OR SERVICES AND PRICES/COSTS\n\nFurnish all supervision, labor, equipment, travel and supplies necessary to perform Semi-Annual periodic routine elevator dumbwaiter inspections, perform Annual Category 1 elevator dumbwaiter periodic inspection and safety tests and one (1) Five Year Load Test of elevators located at the William S. Middleton Memorial Veterans Hospital, 2500 Overlook Terrace, Madison, WI 53705.\n\nBASE PERIOD: July 1, 2026, through June 30, 2027\nCLIN Description QTY Unit Unit Price Total Price\n0001 Semi-Annual Periodic 19 EA $____ $___\nRoutine Elevator/Dumbwaiter\nInspections as per\nStatement of Work\n\n0002 Annual Category 1 19 EA $______ $____\nElevator/Dumbwaiter\nPeriodic Inspection\nand Annual Safety Tests\nper Statement of Work\n\n2003 Five Year Load Test to be 1 EA $_______ $____\nPerformed on Elevators\nper Statement of Work and\nSchedule below:\n\nFive Year Load Test Elevator Schedule (Base Year)\n\nLOCATION ELEVATOR # MANUFACTURER STOP SYSTEM TYPE\n\nBLDG. 1, B-WING PASSENGER P-1 SCHUMACHER 9 GEARLESS TRACTION\n\nBLDG. 1, B-WING PASSENGER P-2 SCHUMACHER 9 GEARLESS TRACTION\n\nBLDG. 1, B-WING PASSENGER P-3 SCHUMACHER 9 GEARLESS TRACTION\n\nBLDG. 1, B-WING PASSENGER P-4 SCHUMACHER 9 GEARLESS TRACTION\n\nBLDG. 1, B-WING FREIGHT 5 SCHUMACHER 10 GEARLESS TRACTION\n\nBLDG. 1, C-WING FREIGHT 6 SCHUMACHER 4 GEARLESS TRACTION\n\nBLDG. 1, D-WING MORGUE SCHUMACHER 10 HYDRAULIC\n\nBLDG. 1, D-WING PASSENGER P-8 SCHUMACHER 10 GEARLESS TRACTION\n\nBLDG. 1, D-WING PASSENGER P-9 SCHUMACHER 10 GEARLESS TRACTION\n\nBLDG. 1, D-WING PASSENGER P-10 SCHUMACHER 10 GEARLESS TRACTION\n\nBLDG. 22 PASSENGER P-1 SCHUMACHER 3 HYDRAULIC\n\nBLDG. 2 PASSENGER P-1 SCHUMACHER 3 HYDRAULIC\n\nBLDG. 6 PASSENGER P-1 SCHUMACHER 2 HYDRAULIC\n\nTotal BASE PERIOD: $__________\n\nOPTION YEAR 1: July 1, 2027, through June 30, 2028\nCLIN Description QTY Unit Unit Price Total Price\n1001 Semi-Annual Periodic 19 EA $____ $___\nRoutine Elevator/Dumbwaiter\nInspections per\nStatement of Work\n\n1002 Annual Category 1 19 EA $______ $____\nElevator/Dumbwaiter\nPeriodic Inspection\nand Annual Safety Tests\nper Statement of Work\n\nTotal OPTION YEAR 1: $_____________\n\nOPTION YEAR 2: July 1, 2028, through June 30, 2029\nCLIN Description QTY Unit Unit Price Total Price\n2001 Semi-Annual Periodic 19 EA $____ $___\nRoutine Elevator/Dumbwaiter\nInspections per\nStatement of Work\n\n2002 Annual Category 1 19 EA $______ $____\nElevator/Dumbwaiter\nPeriodic Inspection\nand Annual Safety Tests\nper Statement of Work\n\nTotal OPTION YEAR 2: $____________\n\nOPTION YEAR 3: July 1, 2029, through June 30, 2030\nCLIN Description QTY Unit Unit Price Total Price\n3001 Semi-Annual Periodic 19 EA $____ $___\nRoutine Elevator/Dumbwaiter\nInspections per\nStatement of Work\n\n3002 Annual Category 1 19 EA $______ $____\nElevator/Dumbwaiter\nPeriodic Inspection\nand Annual Safety Tests\nper Statement of Work\n\nTotal OPTION YEAR 3: $______________\n\nOPTION YEAR 4: July 1, 2030, through June 30, 2031\nCLIN Description QTY Unit Unit Price Total Price\n4001 Semi-Annual Periodic 19 EA $____ $___\nRoutine Elevator/Dumbwaiter\nInspections per\nStatement of Work\n\n4002 Annual Category 1 19 EA $______ $____\nElevator/Dumbwaiter\nPeriodic Inspection\nand Annual Safety Tests\nper Statement of Work\n\nTotal OPTION YEAR 4: $_____________\n\nTOTAL for BASE and ALL OPTION YEARS: $_________________","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25226Q0314","place_of_performance":{"zip":"53705","city":{"name":"Madison"},"state":{"name":"WI"},"street":"William S. Middleton Memorial Veterans Hospital 2500 Overlook Terrace","country":{"name":"United States"}},"product_service_code":"H339"},{"award":{"date":"2026-04-26","amount":"9785.00","number":"36C25226P0323","awardee":{"raw":"Veteran Elevator Inspection Services, LLC CLAYTON 27520 NCL","uei":"GDYANG3BBHR6","cage":"846S5","name":"Veteran Elevator Inspection Services, LLC","location":{"zip":"27520","city":{"name":"CLAYTON"},"state":{"name":"NC"},"country":{"code":"NCL","name":"NEW CALEDONIA"}}}},"dates":{"posted":"2026-04-26","posted_at":"2026-04-26T16:24:20.217Z","award_date":"2026-04-26","created_at":"2026-04-26T16:24:17.964Z","modified_at":"2026-05-27T04:00:05.030Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/12927ab81d2c4072a5eeee7bb23eac17/view"},"naics":{"codes":["541350"],"primary":"541350"},"title":"H339--Madison Elevator Inspection/ Base plus four (Base Year)","agency":{"office":{"code":"36C252","name":"252-NETWORK CONTRACT OFFICE 12 (36C252)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"53214","city":"MILWAUKEE","state":"WI","country":"USA"},"organization_id":"100180018","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-05-26","archive_type":"auto_custom"},"history":[{"index":3,"title":"H339--Madison Elevator Inspection/ Base plus four (Base Year)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-26T16:24:20.217Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"12927ab81d2c4072a5eeee7bb23eac17","solicitation_number":"36C25226Q0314"}],"contacts":[{"name":"Makena James","role":"primary","email":"Makena.James@va.gov","phone":"(414) 844-4871","title":"Contract Specialist"}],"base_type":{"code":"a","label":"Award Notice"},"notice_id":"12927ab81d2c4072a5eeee7bb23eac17","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"12927ab81d2c4072a5eeee7bb23eac17","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-06T01:35:06.394160654Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"84372ad028040b728b132e5ebf0c401a85a51061ac734c440df97e1800515df1","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-06T01:35:06.394160654Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"36C25226Q0314","product_service_code":"H339"}],"due_at":"2026-03-13T15:00:00Z","due_date":"2026-03-13","closes_at":"2026-03-13T15:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","state":"WI","county":"55025","county_name":"Dane County","city":"5548000","city_name":"Madison","country":null,"state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":"GDYANG3BBHR6","amount":"9785.00","linked_awards":2,"cancelled":false,"archived":true,"updated_at":"2026-10-06T01:46:36.679440Z","principal_notice_id":"503792f4938a4706b2aef95466bb92af","description":{"text":"The Department of Veterans Affairs, Great Lakes Acquisition Center (GLAC) is searching for\nvendors with the capabilities to furnish all supervision, labor, equipment, travel and supplies necessary to perform Semi-Annual periodic routine elevator dumbwaiter inspections, perform Annual Category 1 elevator dumbwaiter periodic inspection and safety tests and the Five Year Load Test of elevators and dumbwaiters located at the at the William S. Middleton Memorial Veterans Hospital, 2500 Overlook Terrace, Madison, WI 53705. This will be a base plus four contract. Firm-fixed price.\n\nThe Contractor shall provide all personnel, equipment, material, parts, software, supplies,\nfacilities, transportation, tools, materials, supervision, and other items and non-personal services necessary for execution of the work to be performed under this Contract.\nThe North American Industry Classification System (NAICS) code for this procurement is\n541350.\n\nAll interested, responsible sources must submit a capability statement by March 13th,\n2026 at 10:00 AM CST, to Makena.James@VA.gov to include the following:\nDUNS number, organization name, organization address, point of contact, business size\nunder NAICS 541350, and socioeconomic status.\n\nThis Sources Sought is issued solely for information and planning purposes to determine the availability of qualified vendors and does not constitute a solicitation. All information received in response to this Sources Sought that is marked as proprietary will be handled accordingly.\nPlease note that this is not a request for proposal and the Government is seeking information for market research purposes only. The Government may or may not issue solicitation documents. Please Look for any further information in Contract Opportunities.\nTelephone inquiries will not be returned.\n\nSTATEMENT OF WORK\n\nFurnish all supervision, labor, equipment, travel and supplies necessary to perform Semi-Annual periodic routine elevator dumbwaiter inspections, perform Annual Category 1 elevator dumbwaiter periodic inspection and safety tests and the Five Year Load Test of elevators and dumbwaiters located at the at the William S. Middleton Memorial Veterans Hospital, 2500 Overlook Terrace, Madison, WI 53705.\n\n1. BACKGROUND AND OBJECTIVES: Madison VAH requires two complete periodic routine elevator inspections per year per all ASME codes. Periodic routine elevator inspections include the witness and certification of one (1) Semi-Annual periodic routine elevator /dumbwaiter inspection, one (1) Annual Category 1 periodic elevator/dumbwaiter inspection and safety tests per all ASME codes and the witness of one (1) Five Year Load Test of all of the elevators and dumbwaiters.\n2. REQUIREMENTS AND QUALIFICATIO NS OF ELEVATOR, DUMBWAITER and LIFT INSPECTORS: The inspectors and inspection supervisor shall meet the qualification requirements of the ASME QEI-1. Inspectors and inspection supervisors shall be certified by an organization accredited by ASME in accordance with the requirements of ASME QEI-1. All work performed under this contract shall be accomplished by a QEI-1 certified inspector employed on a permanent basis by the Contractor awarded this contract. The inspectors supervisor shall also be QEI-1 qualified. The inspector and inspection supervisor shall be employed on a permanent basis by the Contractor awarded this contract. The contractor must provide proof of QEI-1 certification for their inspectors and supervisors. Copies of the QEI-1 inspectors and supervisor s certificates shall be provided with the proposal.\n\n3. INSPECTIONS: There shall be two (2) inspections per year, every six months, on all the equipment listed in the Schedule of Elevators and Dumbwaiters. Inspections include a Semi-Annual periodic routine elevator, dumbwaiter and lift inspection and the Annual Category 1 elevator, dumbwaiter and lift periodic inspection and annual safety test inspection. Inspections shall include but are not limited to; inside of the cars, elevator machine rooms and equipment, elevator control room and equipment, secondary equipment and machine rooms, tops of cars, hoist ways, shafts, elevator lobbies and elevator pits.\nAll inspections shall be conducted in accordance with the latest editions of ASME A17.1\nand all current elevator requirements and standards. Inspections shall cover all items as stated in ASME 17.1, Section 8.11.\nInspections shall follow the recommended inspection and test intervals as specified in latest edition of Table N-1 of the ASME A17.1, Safety Code for Elevators.\nAll inspections and tests shall be in accordance with the latest editions of other applicable codes, such as, but not limited to:\nASME A17.1/CSA B44 Safety Code for Elevators and Escalators Current Edition\nASME A17.1 Safety Code for Elevators and escalators Current Edition\nASME A17.2 Guide for Inspection of Elevators, Escalators and Moving Walks Current Edition\nASME A17.3 Safety Code for Existing Elevator and Escalators.\nASME A17.4 Guide for Emergency Evacuation of Passenger from Elevators.\n\n3.1 One (1) site visit/inspection per year, preferred at the first calendar year inspection, shall include, in addition to all required inspections and safety tests, a review of the existing equipment for safety code compliance, including the firefighters' service functions, ADA requirements, as well as recommended upgrades, enhancements or modernization or needs based on long term life expectancy of the current existing equipment. These findings and recommendations shall be submitted in a separate narrative and included with the inspection report.\n3.2 During any inspection, parts shall be removed where necessary to determine the exact condition of parts which could not otherwise be determined, and the equipment shall be cleaned where necessary to make the proper inspection. All parts shall he reinstalled after removal. Elevator inspector shall provide all necessary tools; door pressure gauge, stopwatch, calipers, flashlight and any other small hand tools necessary to conduct inspections.\n\n3.3 All inspections shall be performed in the presence of the elevator maintenance technician, currently under contract as the VA elevator preventative maintenance contractor and a representative from the VA Hospital. The COR at the medical center shall accompany the contractor as an observer, if they choose, during the time of the inspections.\n\n3.4 First inspection shall be within 60 days after contract award. Second inspection shall be 6 months later. All subsequent inspections in the following option years shall be on the same twice per year schedule.\n3.5 Each site visit/inspection shall include an out brief meeting with the COR or VA Rep to discuss the inspection violations, findings, immediate needs, and necessary corrections.\n3.6 In addition to using the standards in the A17.1 and A17.2 Codes, the inspection contractor shall assure that the maintenance contractor s preventative maintenance check charts are up to date and correctly annotated.\n\n3.7 Base Year requirement: Provide to the VA, the latest edition of ASME A17.4 Guide for Emergency Evacuation of Passengers from Elevators. Provide code book with the first base year report.\n4. ANNUAL / SEMI-ANNUAL TEST: The elevator inspector shall be on site to witness and certify the Annual Category 1 safety tests performed with the VA elevator maintenance contractor. Elevator safeties shall be subjected to the annual running tests as required by ASME A17.2 latest edition. The Annual Category 1 safety tests and inspection will be scheduled to concur with one of the required bi-annual inspections. The elevator inspector shall be on site to witness and certify the Semi-Annual inspections and tests and cover all items as specified in the latest editions of ASME A17.2.\n4.1 PERFORMANCE EVALUATION DATA: In addition to the required ASME Annual & Semi-Annual inspections. The Inspection Contractor shall provide an elevator performance evaluation in report form for all elevators, dumbwaiters and lifts once per year.\n5. FIVE-YEAR INSPECTION AND LOAD TEST: The elevator inspector shall be on site to witness and certify the five-year load & safety tests performed by the VA elevator maintenance contractor. The five-year inspection and load tests are performed during off tour hours, between 5:00pm on a Friday and 7:00am on Monday. The Contractor shall be notified in advance by the COR on date and times of the Five Year Inspection & Test. It is anticipated that the five-year load & safety tests will occur in Base Year (2026) of this contract. The five-year inspection and load tests shall be performed during a weekend or holiday to reduce the impact to the facility.\n6. DOCUMENTATION: Each inspection survey/evaluation shall include a comprehensive narrative/report. The narrative/report shall include:\n6.1 Listing and narrative of the operating performance for each elevator/lift.\n6.2 A narrative, which summarizes the inspection and tests conducted.\n6.3 Explains and identifies any conditions found to exist, that require repair or replacement.\n6.4 Provide recommendations as to what actions should be implemented to correct deficiencies and/or conditions identified.\n6.5 Provide list of typical parts that are needed and are recommended for replacement to keep the equipment in good operating condition.\n6.6 Contractor shall if necessary, clearly indicate any adjustments, repairs, or replacements necessary to correct troubles encountered.\n6.7 Shall furnish specifications (if requested by the COR) enough to enable the VA to purchase the materials required for those purposes.\n6.8 Indicate all items and locations inspected.\n6.9 A narrative of all findings and recommendations of the existing equipment as detailed in paragraph 3.1. Narrative and recommendations listed above shall be in addition to standard ASME report/checklists and reports per the required ASME codes.\n6.10 Reports shall be submitted electronically to the VA COR and the VA CO within two (2) weeks after completion of the inspection.\n\n6.11 Provide the latest edition of ASME A17.4 Guide for Emergency Evacuation of Passengers from Elevators code book along with the base year report.\n\n7. RECOGNIZED HOLIDAYS: Unless otherwise indicated, the contractor is not required to perform services on these Federal holidays.\nNew Year s Day Labor Day\nMartin Luther King Jr. Day Columbus Day\nPresidents Day Veterans Day\nMemorial Day Thanksgiving Day\nJuneteenth Christmas Day\nIndependence Day\n\n8. HOURS OF OPERATION: Unless otherwise indicated (such as five-year load test), the contractor is responsible for conducting business, between the hours of 7:00AM and 5:00PM Monday thru Friday except Federal holidays or when the Government facility is closed due to local or national emergencies, administrative closings, or similar Government directed facility closings.\n9. PLACE OF PERFORMANCE: The work to be performed under this contract will be performed at the following government facility:\nWilliam S. Middleton Memorial Veterans Hospital\n2500 Overlook Terrace\nMadison, WI 53705-2286\n\n10. SECURITY REQUIREMENTS: Contractor personnel performing work under this contract must check in with the VA Contracting Officer Representative and shall be escorted by the VA COR or VA rep and the VA elevator maintenance technician during all elevator inspections.\n11. INTERFERENCE TO NORMAL FUNCTION: Contractor personnel are required to interrupt their work at any time so as not to interfere with the normal functioning of the facility, including utility services, fire protection systems, and passage of patients, personnel, equipment, and carts.\n\n12. SAFETY: The Contractor shall consider the clinical environment and instruct his/her employees on applicable safety precautions and specific requirements.\nContractor shall comply with OSHA General Industry and Construction Standards (29 CFR 1910 and 29 CFR 1926. Contractor to provide an OSHA 10 Hour General Industry Training certificate.\nThe contractor is responsible for compliance with all OSHA and other applicable safety regulations. Contractor is required to protect the immediate safety of persons and equipment in and about the elevator(s) during the inspection process.\n\n13. ACRONYMS/DEFINITIONS:\nCO - Contracting Officer\nCOR - Contracting Officer's Representative\nVAH - Department of Veterans Affairs Hospital\nHIPPA- Health Insurance Portability and Accountability Act\n\n14. IDENTIFICATION, PARKING, SMOKING, AND VA REGULATIONS (For any onsite services):\n1. The Contractor's employees and/or subcontractors approved by the COR shall wear visible identification at all time while on the premises of the VAH. Identification shall include, but not be limited to a company identification card, which shall include the company name, employee name, title, and a photograph of the employee.\n\n2. It is the responsibility of the Contractor to park in the appropriate designated parking areas. Information on parking is available from the VAH Police Section. The VAH will not invalidate or make reimbursement for parking violations of the Contractor under any conditions.\n\n3. Any interior or exterior doors that shall be unlocked to gain access shall be kept locked during the performance of work unless it results in the creation of a safety hazard. In those instances, the Contractor is responsible to take necessary actions to maintain the same level of security prior to gaining access/performing work. Should any other devices need to be unlocked like an entry gate, those devices shall be locked immediately upon entry or exit. At no time shall the Contractor allow any person into a locked area or loan keys/access cards to another person. Contractor may be held in default for failure to comply with this requirement and subject the Contractor and employees to contract and other legal remedies.\n\n4. The Contractor agrees that none of its officers or employees shall use or reveal any research, statistical, medical, or security information which may be obtained during the performance of the work or as a result their presence on Government premises without the written consent of the Government.\n\n5. Smoking is prohibited inside any buildings at the VAH.\n\n6. Possession of weapons is prohibited.\n\n7. Enclosed containers, including tool kits, may be subject to search. Violations of VA regulations may result in citation answerable in the United States (Federal) District Court, not a local district, state, or municipal court.\n\nSchedule of Elevators, Dumbwaiters and Lifts\nLOCATION ELEVATOR # MANUFACTURER STOPS SYSTEM TYPE\n\nBLDG. 1, B-WING PASSENGER P1 SCHUMACHER 9 GEARLESS TRACTION\n\nBLDG. 1, B-WING PASSENGER P2 SCHUMACHER 9 GEARLESS TRACTION\n\nBLDG. 1, B-WING PASSENGER P3 SCHUMACHER 9 GEARLESS TRACTION\n\nBLDG. 1, B-WING PASSENGER P4 SCHUMACHER 9 GEARLESS TRACTION\n\nBLDG. 1, B-WING FREIGHT S5 SCHUMACHER 10 GEARLESS TRACTION\n\nBLDG. 1, C-WING FREIGHT S6 SCHUMACHER 5 GEARLESS TRACTION\n\nBLDG. 1, D-WING MORGUE SCHUMACHER 2 HYDRAULIC\n\nBLDG. 1, D-WING PASSENGER P8 SCHUMACHER 10 GEARLESS TRACTION\n\nBLDG. 1, D-WING PASSENGER P9 SCHUMACHER 10 GEARLESS TRACTION\n\nBLDG. 1, D-WING PASSENGER P10 SCHUMACHER 10 GEARLESS TRACTION\n\nBLDG. 1, D-WING MATL/CART LIFT 1 MATOT 2 TRACTION\n\nBLDG. 1, D-WING DUMBWAITER LAB MATOT 2 TRACTION\n\nBLDG. 15 PASSENGER P1 THYSSENKRUPP 6 HYDRAULIC\n\nBLDG. 15 PASSENGER P2 THYSSENKRUPP 6 HYDRAULIC\n\nBLDG. 16 PASSENGER P1 SCHUMACHER 5 HYDRAULIC\n\nBLDG. 22 PASSENGER P1 SCHUMACHER 3 HYDRAULIC\n\nBLDG. 2 PASSENGER P1 SCHUMACHER 3 HYDRAULIC\n\nBLDG. 6 PASSENGER P1 SCHUMACHER 2 HYDRAULIC\n\nBLDG. 2 SERVICE S1 SCHUMACHER 3 HYDRAULIC\n\nSUPPLIES OR SERVICES AND PRICES/COSTS\n\nFurnish all supervision, labor, equipment, travel and supplies necessary to perform Semi-Annual periodic routine elevator dumbwaiter inspections, perform Annual Category 1 elevator dumbwaiter periodic inspection and safety tests and one (1) Five Year Load Test of elevators located at the William S. Middleton Memorial Veterans Hospital, 2500 Overlook Terrace, Madison, WI 53705.\n\nBASE PERIOD: July 1, 2026, through June 30, 2027\nCLIN Description QTY Unit Unit Price Total Price\n0001 Semi-Annual Periodic 19 EA $____ $___\nRoutine Elevator/Dumbwaiter\nInspections as per\nStatement of Work\n\n0002 Annual Category 1 19 EA $______ $____\nElevator/Dumbwaiter\nPeriodic Inspection\nand Annual Safety Tests\nper Statement of Work\n\n2003 Five Year Load Test to be 1 EA $_______ $____\nPerformed on Elevators\nper Statement of Work and\nSchedule below:\n\nFive Year Load Test Elevator Schedule (Base Year)\n\nLOCATION ELEVATOR # MANUFACTURER STOP SYSTEM TYPE\n\nBLDG. 1, B-WING PASSENGER P-1 SCHUMACHER 9 GEARLESS TRACTION\n\nBLDG. 1, B-WING PASSENGER P-2 SCHUMACHER 9 GEARLESS TRACTION\n\nBLDG. 1, B-WING PASSENGER P-3 SCHUMACHER 9 GEARLESS TRACTION\n\nBLDG. 1, B-WING PASSENGER P-4 SCHUMACHER 9 GEARLESS TRACTION\n\nBLDG. 1, B-WING FREIGHT 5 SCHUMACHER 10 GEARLESS TRACTION\n\nBLDG. 1, C-WING FREIGHT 6 SCHUMACHER 4 GEARLESS TRACTION\n\nBLDG. 1, D-WING MORGUE SCHUMACHER 10 HYDRAULIC\n\nBLDG. 1, D-WING PASSENGER P-8 SCHUMACHER 10 GEARLESS TRACTION\n\nBLDG. 1, D-WING PASSENGER P-9 SCHUMACHER 10 GEARLESS TRACTION\n\nBLDG. 1, D-WING PASSENGER P-10 SCHUMACHER 10 GEARLESS TRACTION\n\nBLDG. 22 PASSENGER P-1 SCHUMACHER 3 HYDRAULIC\n\nBLDG. 2 PASSENGER P-1 SCHUMACHER 3 HYDRAULIC\n\nBLDG. 6 PASSENGER P-1 SCHUMACHER 2 HYDRAULIC\n\nTotal BASE PERIOD: $__________\n\nOPTION YEAR 1: July 1, 2027, through June 30, 2028\nCLIN Description QTY Unit Unit Price Total Price\n1001 Semi-Annual Periodic 19 EA $____ $___\nRoutine Elevator/Dumbwaiter\nInspections per\nStatement of Work\n\n1002 Annual Category 1 19 EA $______ $____\nElevator/Dumbwaiter\nPeriodic Inspection\nand Annual Safety Tests\nper Statement of Work\n\nTotal OPTION YEAR 1: $_____________\n\nOPTION YEAR 2: July 1, 2028, through June 30, 2029\nCLIN Description QTY Unit Unit Price Total Price\n2001 Semi-Annual Periodic 19 EA $____ $___\nRoutine Elevator/Dumbwaiter\nInspections per\nStatement of Work\n\n2002 Annual Category 1 19 EA $______ $____\nElevator/Dumbwaiter\nPeriodic Inspection\nand Annual Safety Tests\nper Statement of Work\n\nTotal OPTION YEAR 2: $____________\n\nOPTION YEAR 3: July 1, 2029, through June 30, 2030\nCLIN Description QTY Unit Unit Price Total Price\n3001 Semi-Annual Periodic 19 EA $____ $___\nRoutine Elevator/Dumbwaiter\nInspections per\nStatement of Work\n\n3002 Annual Category 1 19 EA $______ $____\nElevator/Dumbwaiter\nPeriodic Inspection\nand Annual Safety Tests\nper Statement of Work\n\nTotal OPTION YEAR 3: $______________\n\nOPTION YEAR 4: July 1, 2030, through June 30, 2031\nCLIN Description QTY Unit Unit Price Total Price\n4001 Semi-Annual Periodic 19 EA $____ $___\nRoutine Elevator/Dumbwaiter\nInspections per\nStatement of Work\n\n4002 Annual Category 1 19 EA $______ $____\nElevator/Dumbwaiter\nPeriodic Inspection\nand Annual Safety Tests\nper Statement of Work\n\nTotal OPTION YEAR 4: $_____________\n\nTOTAL for BASE and ALL OPTION YEARS: $_________________","html":"The Department of Veterans Affairs, Great Lakes Acquisition Center (GLAC) is searching for \nvendors with the capabilities to furnish all supervision, labor, equipment, travel and supplies necessary to perform Semi-Annual periodic routine elevator dumbwaiter inspections, perform Annual Category 1 elevator dumbwaiter periodic inspection and safety tests and the Five Year Load Test of elevators and dumbwaiters located at the at the William S. Middleton Memorial Veterans Hospital, 2500 Overlook Terrace, Madison, WI 53705. This will be a base plus four contract. Firm-fixed price. \n\nThe Contractor shall provide all personnel, equipment, material, parts, software, supplies, \nfacilities, transportation, tools, materials, supervision, and other items and non-personal services necessary for execution of the work to be performed under this Contract. \nThe North American Industry Classification System (NAICS) code for this procurement is \n541350. \n\nAll interested, responsible sources must submit a capability statement by March 13th, \n2026 at 10:00 AM CST, to Makena.James@VA.gov to include the following: \nDUNS number, organization name, organization address, point of contact, business size \nunder NAICS 541350, and socioeconomic status. \n\nThis Sources Sought is issued solely for information and planning purposes to determine the availability of qualified vendors and does not constitute a solicitation. All information received in response to this Sources Sought that is marked as proprietary will be handled accordingly. \nPlease note that this is not a request for proposal and the Government is seeking information for market research purposes only. The Government may or may not issue solicitation documents. Please Look for any further information in Contract Opportunities. \nTelephone inquiries will not be returned.\n\n\n\n\n\n\nSTATEMENT OF WORK  \n\nFurnish all supervision, labor, equipment, travel and supplies necessary to perform Semi-Annual periodic routine elevator dumbwaiter inspections, perform Annual Category 1 elevator dumbwaiter periodic inspection and safety tests and the Five Year Load Test of elevators and dumbwaiters located at the at the William S. Middleton Memorial Veterans Hospital, 2500 Overlook Terrace, Madison, WI 53705.\n\n1. BACKGROUND AND OBJECTIVES:  Madison VAH requires two complete periodic routine elevator inspections per year per all ASME codes.   Periodic routine elevator inspections include the witness and certification of one (1) Semi-Annual periodic routine elevator /dumbwaiter inspection, one (1) Annual Category 1 periodic elevator/dumbwaiter inspection and safety tests per all ASME codes and the witness of one (1) Five Year Load Test of all of the elevators and dumbwaiters. \n2. REQUIREMENTS AND QUALIFICATIO NS OF ELEVATOR, DUMBWAITER and LIFT INSPECTORS:  The inspectors and inspection supervisor shall meet the qualification requirements of the ASME QEI-1. Inspectors and inspection supervisors shall be certified by an organization accredited by ASME in accordance with the requirements of ASME QEI-1.  All work performed under this contract shall be accomplished by a QEI-1 certified inspector employed on a permanent basis by the Contractor awarded this contract.  The inspectors  supervisor shall also be QEI-1 qualified.  The inspector and inspection supervisor shall be employed on a permanent basis by the Contractor awarded this contract.  The contractor must provide proof of QEI-1 certification for their inspectors and supervisors.  Copies of the QEI-1 inspectors and supervisor s certificates shall be provided with the proposal.\n  \n3. INSPECTIONS:  There shall be two (2) inspections per year, every six months, on all the equipment listed in the Schedule of Elevators and Dumbwaiters. Inspections include a Semi-Annual periodic routine elevator, dumbwaiter and lift inspection and the Annual Category 1 elevator, dumbwaiter and lift periodic inspection and annual safety test inspection.  Inspections shall include but are not limited to; inside of the cars, elevator machine rooms and equipment, elevator control room and equipment, secondary equipment and machine rooms, tops of cars, hoist ways, shafts, elevator lobbies and elevator pits.  \nAll inspections shall be conducted in accordance with the latest editions of ASME A17.1 \nand all current elevator requirements and standards. Inspections shall cover all items as stated in ASME 17.1, Section 8.11.\nInspections shall follow the recommended inspection and test intervals as specified in latest edition of Table N-1 of the ASME A17.1, Safety Code for Elevators.  \nAll inspections and tests shall be in accordance with the latest editions of other applicable codes, such as, but not limited to: \nASME A17.1/CSA B44 Safety Code for Elevators and Escalators   Current Edition\nASME A17.1 Safety Code for Elevators and escalators   Current Edition\nASME A17.2 Guide for Inspection of Elevators, Escalators and Moving Walks   Current Edition\nASME A17.3 Safety Code for Existing Elevator and Escalators. \nASME A17.4 Guide for Emergency Evacuation of Passenger from Elevators.\n\n3.1  One (1) site visit/inspection per year, preferred at the first calendar year inspection, shall include, in addition to all required inspections and safety tests, a review of the existing equipment for safety code compliance, including the firefighters' service functions, ADA requirements, as well as recommended upgrades, enhancements or modernization or needs based on long term life expectancy of the current existing equipment.  These findings and recommendations shall be submitted in a separate narrative and included with the inspection report. \n3.2  During any inspection, parts shall be removed where necessary to determine the exact condition of parts which could not otherwise be determined, and the equipment shall be cleaned where necessary to make the proper inspection. All parts shall he reinstalled after removal.  Elevator inspector shall provide all necessary tools; door pressure gauge, stopwatch, calipers, flashlight and any other small hand tools necessary to conduct inspections.\n\n3.3  All inspections shall be performed in the presence of the elevator maintenance technician, currently under contract as the VA elevator preventative maintenance contractor and a representative from the VA Hospital.  The COR at the medical center shall accompany the contractor as an observer, if they choose, during the time of the inspections.  \n\n3.4  First inspection shall be within 60 days after contract award.  Second inspection shall be 6 months later.  All subsequent inspections in the following option years shall be on the same twice per year schedule. \n3.5  Each site visit/inspection shall include an out brief meeting with the COR or VA Rep to discuss the inspection violations, findings, immediate needs, and necessary corrections. \n3.6  In addition to using the standards in the A17.1 and A17.2 Codes, the inspection contractor shall assure that the maintenance contractor s preventative maintenance check charts are up to date and correctly annotated. \n\n3.7  Base Year requirement:  Provide to the VA,  the latest edition of ASME A17.4 Guide for Emergency Evacuation of Passengers from Elevators. Provide code book with the first base year report.\n4. ANNUAL / SEMI-ANNUAL TEST: The elevator inspector shall be on site to witness and certify the Annual Category 1 safety tests performed with the VA elevator maintenance contractor.  Elevator safeties shall be subjected to the annual running tests as required by ASME A17.2 latest edition. The Annual Category 1 safety tests and inspection will be scheduled to concur with one of the required bi-annual inspections.  The elevator inspector shall be on site to witness and certify the Semi-Annual inspections and tests and cover all items as specified in the latest editions of ASME A17.2.  \n4.1 PERFORMANCE EVALUATION DATA:  In addition to the required ASME Annual & Semi-Annual inspections.  The Inspection Contractor shall provide an elevator performance evaluation in report form for all elevators, dumbwaiters and lifts once per year.  \n5. FIVE-YEAR INSPECTION AND LOAD TEST:  The elevator inspector shall be on site to witness and certify the five-year load & safety tests performed by the VA elevator maintenance contractor.  The five-year inspection and load tests are performed during off tour hours, between 5:00pm on a Friday and 7:00am on Monday.  The Contractor shall be notified in advance by the COR on date and times of the Five  Year Inspection & Test.  It is anticipated that the five-year load & safety tests will occur in Base Year (2026) of this contract.  The five-year inspection and load tests shall be performed during a weekend or holiday to reduce the impact to the facility. \n 6. DOCUMENTATION:  Each inspection survey/evaluation shall include a comprehensive narrative/report.  The narrative/report shall include:\n6.1 Listing and narrative of the operating performance for each elevator/lift. \n6.2 A narrative, which summarizes the inspection and tests conducted.  \n6.3 Explains and identifies any conditions found to exist, that require repair or replacement. \n6.4 Provide recommendations as to what actions should be implemented to correct deficiencies and/or conditions identified. \n 6.5 Provide list of typical parts that are needed and are recommended for replacement to keep the equipment in good operating condition. \n6.6 Contractor shall if necessary, clearly indicate any adjustments, repairs, or replacements necessary to correct troubles encountered.  \n6.7 Shall furnish specifications (if requested by the COR) enough to enable the VA to purchase the materials required for those purposes.  \n6.8 Indicate all items and locations inspected.\n6.9 A narrative of all findings and recommendations of the existing equipment as detailed in paragraph 3.1.  Narrative and recommendations listed above shall be in addition to standard ASME report/checklists and reports per the required ASME codes.  \n6.10 Reports shall be submitted electronically to the VA COR and the VA CO within two (2) weeks after completion of the inspection.  \n\n6.11 Provide the latest edition of ASME A17.4 Guide for Emergency Evacuation of Passengers from Elevators code book along with the base year report.\n\n7. RECOGNIZED HOLIDAYS:   Unless otherwise indicated, the contractor is not required to perform services on these Federal holidays.      \nNew Year s Day     Labor Day\nMartin Luther King Jr. Day    Columbus Day\nPresidents  Day     Veterans Day\nMemorial Day      Thanksgiving Day\nJuneteenth       Christmas Day    \nIndependence Day     \n\n8. HOURS OF OPERATION:  Unless otherwise indicated (such as five-year load test), the contractor is responsible for conducting business, between the hours of 7:00AM and 5:00PM Monday thru Friday except Federal holidays or when the Government facility is closed due to local or national emergencies, administrative closings, or similar Government directed facility closings.  \n9. PLACE OF PERFORMANCE:  The work to be performed under this contract will be performed at the following government facility: \nWilliam S. Middleton Memorial Veterans Hospital  \n2500 Overlook Terrace     \nMadison, WI  53705-2286  \n\n10. SECURITY REQUIREMENTS:  Contractor personnel performing work under this contract must check in with the VA Contracting Officer Representative and shall be escorted by the VA COR or VA rep and the VA elevator maintenance technician during all elevator inspections.\n11. INTERFERENCE TO NORMAL FUNCTION:  Contractor personnel are required to interrupt their work at any time so as not to interfere with the normal functioning of the facility, including utility services, fire protection systems, and passage of patients, personnel, equipment, and carts.\n\n12. SAFETY:  The Contractor shall consider the clinical environment and instruct his/her employees on applicable safety precautions and specific requirements. \nContractor shall comply with OSHA General Industry and Construction Standards (29 CFR 1910 and 29 CFR 1926.  Contractor to provide an OSHA 10 Hour General Industry Training certificate. \nThe contractor is responsible for compliance with all OSHA and other applicable safety regulations.  Contractor is required to protect the immediate safety of persons and equipment in and about the elevator(s) during the inspection process.  \n\n13.  ACRONYMS/DEFINITIONS:\nCO - Contracting Officer\nCOR - Contracting Officer's Representative\nVAH - Department of Veterans Affairs Hospital\nHIPPA- Health Insurance Portability and Accountability Act\n\n14. IDENTIFICATION, PARKING, SMOKING, AND VA REGULATIONS (For any onsite services): \n1.  The Contractor's employees and/or subcontractors approved by the COR shall wear visible identification at all time while on the premises of the VAH.  Identification shall include, but not be limited to a company identification card, which shall include the company name, employee name, title, and a photograph of the employee. \n\n2.  It is the responsibility of the Contractor to park in the appropriate designated parking areas.  Information on parking is available from the VAH Police Section.  The VAH will not invalidate or make reimbursement for parking violations of the Contractor under any conditions.  \n  \n3.  Any interior or exterior doors that shall be unlocked to gain access shall be kept locked during the performance of work unless it results in the creation of a safety hazard.  In those instances, the Contractor is responsible to take necessary actions to maintain the same level of security prior to gaining access/performing work.  Should any other devices need to be unlocked like an entry gate, those devices shall be locked immediately upon entry or exit.  At no time shall the Contractor allow any person into a locked area or loan keys/access cards to another person.  Contractor may be held in default for failure to comply with this requirement and subject the Contractor and employees to contract and other legal remedies.\n\n4.  The Contractor agrees that none of its officers or employees shall use or reveal any research, statistical, medical, or security information which may be obtained during the performance of the work or as a result their presence on Government premises without the written consent of the Government.\n \n5.  Smoking is prohibited inside any buildings at the VAH.\n\n6.  Possession of weapons is prohibited.\n\n7.  Enclosed containers, including tool kits, may be subject to search.  Violations of VA regulations may result in citation answerable in the United States (Federal) District Court, not a local district, state, or municipal court.   \n\n\n\n\n\nSchedule of Elevators, Dumbwaiters and Lifts\nLOCATION          ELEVATOR #               MANUFACTURER       STOPS        SYSTEM TYPE\n \nBLDG. 1, B-WING PASSENGER P1  SCHUMACHER            9        GEARLESS TRACTION\n\nBLDG. 1, B-WING PASSENGER P2  SCHUMACHER            9        GEARLESS TRACTION\n\nBLDG. 1, B-WING PASSENGER P3  SCHUMACHER            9         GEARLESS TRACTION\n\nBLDG. 1, B-WING PASSENGER P4  SCHUMACHER            9         GEARLESS TRACTION\n\nBLDG. 1, B-WING          FREIGHT S5   SCHUMACHER          10         GEARLESS TRACTION\n\nBLDG. 1, C-WING          FREIGHT S6                SCHUMACHER 5         GEARLESS TRACTION\n\nBLDG. 1, D-WING MORGUE   SCHUMACHER            2         HYDRAULIC  \n\nBLDG. 1, D-WING         PASSENGER P8  SCHUMACHER          10        GEARLESS TRACTION\n\nBLDG. 1, D-WING PASSENGER P9            SCHUMACHER          10       GEARLESS TRACTION\n\nBLDG. 1, D-WING PASSENGER P10        SCHUMACHER           10      GEARLESS TRACTION\n\nBLDG. 1, D-WING MATL/CART LIFT 1  MATOT   2         TRACTION \n\nBLDG. 1, D-WING DUMBWAITER  LAB  MATOT  2         TRACTION\n\nBLDG. 15  PASSENGER P1  THYSSENKRUPP 6          HYDRAULIC\n \nBLDG. 15  PASSENGER P2  THYSSENKRUPP 6          HYDRAULIC\n\nBLDG. 16                       PASSENGER P1            SCHUMACHER            5          HYDRAULIC\n       \nBLDG. 22  PASSENGER P1   SCHUMACHER 3          HYDRAULIC\n\nBLDG. 2          PASSENGER P1  SCHUMACHER 3          HYDRAULIC\n\nBLDG. 6  PASSENGER P1           SCHUMACHER 2          HYDRAULIC\n\nBLDG. 2          SERVICE S1   SCHUMACHER 3         HYDRAULIC\n\n\n\n\n\n\n\n\n\n\n\n\nSUPPLIES OR SERVICES AND PRICES/COSTS\n\nFurnish all supervision, labor, equipment, travel and supplies necessary to perform Semi-Annual periodic routine elevator dumbwaiter inspections, perform Annual Category 1 elevator dumbwaiter periodic inspection and safety tests and one (1) Five Year Load Test of elevators located at the William S. Middleton Memorial Veterans Hospital, 2500 Overlook Terrace, Madison, WI 53705.\n\nBASE PERIOD: July 1, 2026, through June 30, 2027\nCLIN       Description                       QTY          Unit        Unit Price                   Total Price\n0001    Semi-Annual Periodic             19            EA            $____             $___\n             Routine Elevator/Dumbwaiter \nInspections as per \nStatement of Work\n\n0002   Annual Category 1                      19           EA              $______        $____\n Elevator/Dumbwaiter\nPeriodic Inspection\nand Annual Safety Tests\n per Statement of Work \n                                                        \n2003 Five Year Load Test to be         1              EA                $_______     $____\n Performed on Elevators\n per Statement of Work and \nSchedule below: \n\nFive Year Load Test Elevator Schedule (Base Year) \n\nLOCATION          ELEVATOR #               MANUFACTURER       STOP         SYSTEM TYPE\n \nBLDG. 1, B-WING PASSENGER P-1  SCHUMACHER            9        GEARLESS TRACTION\n\nBLDG. 1, B-WING PASSENGER P-2  SCHUMACHER            9        GEARLESS TRACTION\n\nBLDG. 1, B-WING PASSENGER P-3  SCHUMACHER            9         GEARLESS TRACTION\n\nBLDG. 1, B-WING PASSENGER P-4  SCHUMACHER            9         GEARLESS TRACTION\n\nBLDG. 1, B-WING          FREIGHT 5   SCHUMACHER          10         GEARLESS TRACTION\n\nBLDG. 1, C-WING          FREIGHT 6                   SCHUMACHER           4          GEARLESS TRACTION\n\nBLDG. 1, D-WING         MORGUE                       SCHUMACHER            10         HYDRAULIC\n\nBLDG. 1, D-WING         PASSENGER P-8          SCHUMACHER            10         GEARLESS TRACTION\n\nBLDG. 1, D-WING         PASSENGER P-9          SCHUMACHER            10         GEARLESS TRACTION\n\nBLDG. 1, D-WING         PASSENGER P-10        SCHUMACHER            10         GEARLESS TRACTION\n\nBLDG. 22  PASSENGER P-1   SCHUMACHER 3           HYDRAULIC\n\nBLDG. 2          PASSENGER P-1  SCHUMACHER 3 HYDRAULIC\n\nBLDG. 6  PASSENGER P-1           SCHUMACHER 2 HYDRAULIC\n                                                                                                                                                                                        \n\n \n\nTotal BASE PERIOD: $__________\n\n\nOPTION YEAR 1: July 1, 2027, through June 30, 2028 \nCLIN       Description                        QTY          Unit               Unit Price                Total Price\n1001    Semi-Annual Periodic             19            EA            $____             $___\n             Routine Elevator/Dumbwaiter \nInspections per \nStatement of Work\n\n1002   Annual Category 1                      19          EA              $______        $____\n Elevator/Dumbwaiter\nPeriodic Inspection\nand Annual Safety Tests\n per Statement of Work \n\n                                                         Total OPTION YEAR 1: $_____________\n\n\n\n\n\n\n\n\n\nOPTION YEAR 2: July 1, 2028, through June 30, 2029\nCLIN       Description                       QTY          Unit                   Unit Price                Total Price\n2001    Semi-Annual Periodic             19             EA            $____             $___\n             Routine Elevator/Dumbwaiter \nInspections per \nStatement of Work\n\n2002   Annual Category 1                      19          EA              $______        $____\n Elevator/Dumbwaiter\nPeriodic Inspection\nand Annual Safety Tests\n per Statement of Work \n\n\n                                                         Total OPTION YEAR 2: $____________\n\n\n\n\nOPTION YEAR 3: July 1, 2029, through June 30, 2030\nCLIN       Description                      QTY          Unit            Unit Price                Total Price\n3001    Semi-Annual Periodic             19            EA            $____             $___\n             Routine Elevator/Dumbwaiter \nInspections per \nStatement of Work\n\n3002  Annual Category 1                      19          EA              $______        $____\n Elevator/Dumbwaiter\nPeriodic Inspection\nand Annual Safety Tests\n per Statement of Work \n\n                                                         Total OPTION YEAR 3: $______________\n\n\n\n\n\nOPTION YEAR 4: July 1, 2030, through June 30, 2031\nCLIN       Description                      QTY          Unit                Unit Price                Total Price\n4001    Semi-Annual Periodic             19          EA            $____             $___\n             Routine Elevator/Dumbwaiter \nInspections per \nStatement of Work\n\n4002  Annual Category 1                      19           EA              $______        $____\n Elevator/Dumbwaiter\nPeriodic Inspection\nand Annual Safety Tests\n per Statement of Work \n\n                                                        Total OPTION YEAR 4: $_____________\n\n\n\nTOTAL for BASE and ALL OPTION YEARS:  $_________________","origin":"detail"},"contacts":[{"name":"Makena James","role":"primary","email":"Makena.James@va.gov","phone":"(414) 844-4871","title":"Contract Specialist"}],"place_of_performance":{"zip":"53705","city":{"name":"Madison"},"state":{"name":"WI"},"street":"William S. Middleton Memorial Veterans Hospital 2500 Overlook Terrace","country":{"name":"United States"}},"office_address":{"zip":"53214","city":"MILWAUKEE","state":"WI","country":"USA"},"naics_codes":["541350"],"award":{"awardee":{}},"attachments":[{"resource_id":"37c8061288bc42c4b0ec4ed2c7a0d9ca","name":"36C25226P0323_1.docx","kind":"file","mime_type":".docx","size_bytes":13671,"posted_at":"2026-04-26T16:24:20.217Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/37c8061288bc42c4b0ec4ed2c7a0d9ca/download","mirrored":false},{"resource_id":"9776becf2eed41d393ef4c8ad9104202","name":"36C25226Q0314.docx","kind":"file","mime_type":".docx","size_bytes":28804,"posted_at":"2026-03-04T15:50:42.997Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/9776becf2eed41d393ef4c8ad9104202/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C25226P0323_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C25226P0323_3600_-NONE-_-NONE-/","piid":"36C25226P0323","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"GDYANG3BBHR6","recipient_name":"VETERAN ELEVATOR INSPECTION SERVICES, LLC","recipient_uei":"GDYANG3BBHR6","recipient_cage":"846S5","recipient_city":"CLAYTON","recipient_state":"NC","sub_name":"Department of Veterans Affairs","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","office_key":"o-36C252","first_action_date":"2026-04-26","last_action_date":"2026-10-14","actions":2,"obligated":"9785.00","current_total_value":"9785.00","potential_total_value":"36195.00","naics":"541350","psc":"H339","extent_competed":"COMPETED UNDER SAP","set_aside":"SERVICE DISABLED VETERAN OWNED SMALL BUSINESS SET-ASIDE","offers_received":2,"description":"ELEVATOR INSPECTION SERVICES AT THE MADISON, WI VAMC","method":"piid","confidence":"high","evidence":["award number 36C25226P0323 equals the contract number","same awarding office 36C252"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C25227Q0069","latest_notice_id":"eed58f84a7f44ac98ced93c2b5e9ec8d","title":"S222--Grease Trap Service-FY27 Base-Tomah VAMC - December 2026 - November 2027","solicitation_number":"36C25227Q0069","notice_type":"o","first_type":"p","first_posted":"2026-11-04","last_posted":"2026-11-19","notices":3,"due_at":"2026-11-27T16:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"562998","psc":"S222","set_aside":"SBA","state":"WI","county":"55081","county_name":"Monroe County","city":"5580075","city_name":"Tomah","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Tomah VA Medical Center","site_key":"tomah-va-medical-center-wi","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C25227Q0033","latest_notice_id":"4d3caf6262ae49649e71c4eadbda1187","title":"Q702--Great Lakes Region Durable Medical Equipment (DME) Delivery Services","solicitation_number":"36C25227Q0033","notice_type":"o","first_type":"o","first_posted":"2026-11-06","last_posted":"2026-11-19","notices":3,"due_at":"2026-11-30T12:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T12:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"621610","psc":"Q702","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C25227B00020001","latest_notice_id":"7eafb50009534028818a8ee9836b9e30","title":"Z1DA--550-20-121 Demo Old Boiler Plant B100 (CON)","solicitation_number":"36C25227B0002-0001","notice_type":"o","first_type":"o","first_posted":"2026-10-21","last_posted":"2026-11-10","notices":2,"due_at":"2026-12-02T19:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"IL","county":"17183","county_name":"Vermilion County","city":"1718563","city_name":"Danville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"36C25227Q0059","latest_notice_id":"356844aa4dfe401da0c9186aa3e03e85","title":"4130--Chiller Compressor Replacement at the Edward Hines Jr. VA Hospital (Hines) Building 228","solicitation_number":"36C25227Q0059","notice_type":"o","first_type":"r","first_posted":"2026-10-16","last_posted":"2026-11-16","notices":2,"due_at":"2026-12-03T16:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"238220","psc":"J043","set_aside":"SDVOSBC","state":"IL","county":"17031","county_name":"Cook County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C25227B0006","latest_notice_id":"e4fa6ced73cf448f9259359ef2b8eeab","title":"Z1DA--537-26-101 Construction of Ogden Elevator Cab Interiors Jesse Brown VA Medical Center","solicitation_number":"36C25227B0006","notice_type":"p","first_type":"p","first_posted":"2026-10-20","last_posted":"2026-10-20","notices":1,"due_at":"2026-12-04T16:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"238290","psc":"Z1DA","set_aside":"SDVOSBC","state":"IL","county":"17031","county_name":"Cook County","city":"1714000","city_name":"Chicago","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":"Jesse Brown VA Medical Center","site_key":"jesse-brown-va-medical-center-il","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-21T04:57:30.751375Z"}],"similar_open":[{"key":"36C25526Q0617","latest_notice_id":"3506983a2af048deaf442eae0f8b8a04","title":"H112--Annual/Sem-i annual fire smoke inspections and auto door services l EKH","solicitation_number":"36C25526Q0617","notice_type":"o","first_type":"r","first_posted":"2026-08-19","last_posted":"2026-11-18","notices":11,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"541350","psc":"H112","set_aside":"SBA","state":"KS","county":"20103","county_name":"Leavenworth County","city":"2039000","city_name":"Leavenworth","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"15DDHQ27R00000001","latest_notice_id":"bf980e13286649b7a1ed1898b4d44b95","title":"Aviation Operations Center (AOC)- Building Engineer Report (BER)","solicitation_number":"15DDHQ27R00000001","notice_type":"k","first_type":"k","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-015","dept_name":"JUSTICE, DEPARTMENT OF","sub_key":"s-1524","sub_name":"DRUG ENFORCEMENT ADMINISTRATION","office_key":"o-15DDFA","office_name":"OFFICE ACQUISITION MANAGEMENT","naics":"541350","psc":"H156","set_aside":"SBA","state":"TX","county":null,"county_name":null,"city":"4827000","city_name":"Fort Worth","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"36C25727Q00310002","latest_notice_id":"c463c6aa97b7496d99268a3c961117de","title":"NTX Elevator Inspection - Amendment","solicitation_number":"36C25727Q0031-0002","notice_type":"k","first_type":"k","first_posted":"2026-11-04","last_posted":"2026-11-04","notices":1,"due_at":"2026-11-30T21:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"541350","psc":"J036","set_aside":"SDVOSBC","state":"TX","county":"48113","county_name":"Dallas County","city":"4819000","city_name":"Dallas","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-05T04:36:35.392694Z"}],"similar_open_total":9,"indexable":false}