Skip to content

SealedBidder is a private company, not a government agency.

Sign upDashboard
  • 8,434 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell SealedBidder what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and SealedBidder tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $99 a month. See your matches before you pay.
See plans

Sources sought

Sources Sought Ophthalmology Chairs, Instrument Stands and Lighting System for the Madison WI, VAMC

36C25225Q0494

Department of Veterans Affairs, 252-Network Contract Office 12. Surgical and Medical Instrument Manufacturing.

Response deadline

June 6, 2025 at 12:59 AM EDT

Closed 538 days ago. Posted May 30, 2025. Scheduled to archive July 6, 2025.

Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities

This one closed in 2025

16 like it are open now in surgical and medical instrument manufacturing

All 16 open in surgical and medical instrument manufacturing

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
Who may compete
SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 339112 (surgical and medical instrument manufacturing), means no more than 1,000 employees, counted with affiliates. What a set-aside is
What comes next
No solicitation was published under this number after the sources sought of May 30, 2025. An agency sometimes issues the solicitation under a new number.

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov.

THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE. The NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI 53214, is performing market research to determine if there is a sufficient number of qualified: (1) Service Disabled Veteran Owned Small Business (SDVOSB); (2) Veteran Owned Small Business (VOSB); or (3) Small or emerging small business firms, or (4) Other Than Small business firms, to provide the items listed below to the Madison, WI VAMC. RELIANCE 7000-FULL POWER ARTICULATING EXAM CHAIR BASE RELIANCE 7900 INSTRUMENT STAND-INSTRUMENT CONSOLE & WHEELCHAIR COMPATIBLE RELIANCE ECLIPSE ROOM LIGHTING SYSTEM - TRI ZONE FLUORESCENT ON/OFF/FLUORESCENT DIMMING RELIANCE ECLIPSE ROOM LIGHTING SYSTEM - ECLIPSE HANGER KITS FOR MODEL 7900 RELIANCE 940 CHAIR GLIDE/CHAIR MOVER INSTALLATION OF ITEMS General Requirements: Salient Characteristics: Reliance 7000 Exam and Minor Procedures Chair (P/N 070025) Brand Name or Equal Chair must be able to rotate/swivel at least 330 degrees. Chair lift capacity must be 600 pounds. Chair back must be able to be reclined near flat. Chair must have a minimum ground to seat height of at least 20 inches. Chair must be able to raise the patient at least 28 inches from the ground. Chair needs to have controls on both sides of the chair to control height and reclining positions Chair must have foot pedal included to control height and reclining positions. Chair needs to be compatible with a chair mover (or glider) to accommodate patients in wheelchairs who cannot transfer to the exam chair. Chair needs to be compatible with Reliance instrument stand. Chair should come with a 2-year warranty with the option of an extended warranty. Reliance 7900 Instrument Stand with Wheelchair Compatibility (P/N 7900IC/WC) Brand Name or Equal Counterbalanced slit lamp arm needs to allow 12 of vertical travel and be able to support instruments up to 60 lbs. The upper refractor arm has a minimum of 10 vertical range, and delivers instruments weighing up to 20 lbs. Stand needs to have ability to control the height of the exam chair. Stand needs to have three designated instrument recharging stations, minimum of three instruments at a time. Stand needs to have built in standard plug outlets on the back of the unit. Stand needs to have an overhead halogen lamp on adjustable arm for minor procedures. Stand must be compatible with Reliance exam chairs. Stand must have an option for a Room Light Control that activates all room lighting from the stand or small console. Lighting adjusts based on instrument moves or quick manual adjustment. Stand should come with a 2-year warranty with the option of an extended warranty. Reliance Eclipse Room Lighting Control (Integrated into 7900IC/WC) Brand Name or Equal Must be a part of the Instrument Stand. Must be able to control all examination room lighting. Must be triggered manually and automatically by handheld instrument movement. Must be able to control, incandescent, fluorescent, and LED lighting. Must be able to dim fluorescent lights to 1% of output without light noise or flickers. Must require minimal exam room rewiring. Reliance 940 Chair Glide/Chair Mover (P/N 940002) Brand Name or Equal Must be compatible with the Reliance Exam Chairs. Must have a stainless-steel base plate and a heavy-duty cast aluminum carriage. Must enable the practitioner to effortlessly slide chair out of the way and replace it with a wheelchair with a 27 range of travel. Must have a conveniently located foot lever that activates and releases a friction lock that secures the chair in position anywhere along its 27 path. Glide should come with a 2-year warranty with the option of an extended warranty. INSTALLATION OF ITEMS All interested firms who can meet the requirements stated above should respond, in writing, INCLUDING ALL THE FOLLOWING: Company name. Address. Point of contact (name/title/telephone number/e-mail address). FSS / SEWP Contract number, if applicable. SAM Unique ID number. Tax ID number. Indication of which business category (SDVOSB, VOSB, Small Business or Other Than Small Business) for which the organization qualifies. A capability statement that addresses the organizations qualifications and ability to provide the requirement depicted above. Documentation from manufacturer (i.e. correspondence from manufacturer) of your firm being an authorized distributor for the manufacturer. Submit responses to the Contracting Specialist, Ryan Nugent, at Ryan.Nugent@va.gov no later than 11:59 PM (Central Standard Time), 5/June/2025. 36C25225Q0494 Reliance Chair and Stands Shall be referenced on all correspondence regarding this announcement. TELEPHONIC INQUIRIES WILL NOT BE ACCEPTED. The NAICS Code 339112, Surgical and Medical Instrument Manufacturing, is applicable to this acquisition; the size standard is 1,000 employees. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Systems for Award Management (SAM) database prior to award of a contract. The Government will use responses to this notice to make an appropriate acquisition decision. This is the only notice; no other copies of this notice will be provided

Attachments

Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. May 30, 2025

    Sources sought

    Due June 6, 2025 at 12:59 AM EDT. SAM.gov, notice bd104cef3310401ca8db1e6fd16fb635

    1 revision on SAM
    • May 30, 2025: publish, sources sought

Points of contact