Skip to content

SealedBidder is a private company, not a government agency.

Sign upDashboard
  • 8,434 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell SealedBidder what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and SealedBidder tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $99 a month. See your matches before you pay.
See plans

Special notice

HVAC Refurbishment and Restoration (21 units) at Captain James Lovell FHCC Intent to Sole Source

36C25225Q0453

Department of Veterans Affairs, 252-Network Contract Office 12. Plumbing, Heating, and Air-Conditioning Contractors.

Response deadline

June 11, 2025 at 11:00 AM EDT

Closed 533 days ago. Posted June 6, 2025. Scheduled to archive August 10, 2025.

Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities

This one closed in 2025

57 like it are open now in plumbing, heating, and air-conditioning contractors

All 57 open in plumbing, heating, and air-conditioning contractors

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Special notice. Industry days, draft requirements, program announcements and other notices that are not a solicitation. Glossary

Description

As published on SAM.gov.

Under Statutory Authority 41 U.S.C. 1901 the VA Great Lakes Acquisition Center (GLAC) intends to negotiate a sole source contract AIR QUALITY INNOVATIVE SOLUTIONS LLC for Refurbish and Maintenance Services on HVAC Air Handler Units (21 units) at the Captain James Lovell FHCC located in North Chicago, IL. This acquisition is conducted under the authority of FAR 8.405-6(a)(1)(b), Only one source is capable of providing the supplies or services required at the level of quality required because the supplies or services are unique or highly specialized. This will be a firm fixed price contract (one-time purchase) under NAICS 238220. The FHCC is looking for vendors who are capable of providing services that use ATP Testing to facilitate equipment to function in conformance with the latest published edition of National Fire Protection Association Code 90A (NFPA 90A), Occupational Safety and Health Administration (OSHA), Joint Commission (TJC), and Veterans Administration (VA) standards. ATP Testing in HVAC air handlers refers to the process of measuring the presence of adenosine triphosphate (ATP), which is an indicator of biological activity. This testing helps evaluate the cleanliness of air conditioning systems by detecting the presence of active organic matter, such as bacteria and viruses, which can indicate potential contamination. ATP testing is crucial for ensuring the sanitation of HVAC systems, particularly in environments where hygiene is critical, such as hospitals and food facilities. Standards for ATP testing is set by the Air Conditioning, Heating and Refrigeration Institute (AHRI). FHCC is looking for vendors to: Coordinate with the facility to de-energize AHUs. Isolate air handling unit by sealing off adjacent ductwork and using air scrubbing machines. Clean and prepare all surfaces that will be addressed by the contractor including the removal of non-compliant coatings and foams. Reinforce compromised surfaces with steel as needed to restore structure. Apply CPR-SL Epoxy (self-leveling) at 3/16 nominal thickness and 6 up walls throughout all chamber floors & condensate pans to stop leaks and halt corrosion. Apply Fire Barrier over all epoxy for compliance with NFPA 90A fire code. Apply Antimicrobial Topcoat over all fire barrier to ensure watertight surface and provide an active antimicrobial surface. Apply MVS (Multi-acrylic, corrosion resistant, antimicrobial coating) on walls, ceiling, fan housing & structural steel. Conduct Coil Restoration on all coils for the removal of biofilm and debris Once coil restoration is complete, Contractor must perform pre & post restoration ATP Testing to measure microbial activity on the cooling coil both before and after and coil restoration. Confirm proper operation of existing drains and traps prior to re-commissioning. Generate a detailed Installation Report which includes results from differential pressure readings and ATP Testing This Notice of Intent is not a request for competitive quotes. No solicitation documents are available and telephone requests will not be honored. However, if a firm believes it can meet the requirements it must furnish information about its products and services, as well as references from other customers who are using these products and service to the Contracting Officer by Wednesday 06/11/2025 at 10:00am. Supporting evidence must be furnished in sufficient detail to demonstrate the ability to comply with the above requirements.

Attachments

Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. June 6, 2025

    Special notice

    Due June 11, 2025 at 11:00 AM EDT. SAM.gov, notice c75370aba09a407d9c28d9231f5fb4d6

    1 revision on SAM
    • June 6, 2025: publish, special notice

Points of contact