{"canonical":"https://sealedbidder.com/opportunities/36c25225b0011","key":"36C25225B0011","url":"https://sealedbidder.com/opportunities/36c25225b0011","title":"Z1DA--578-15-001 Install Patient Lifts - Construction Multiple Locations","solicitation_number":"36C25225B0011","notice_type":"a","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-04-22T18:00:00Z","first_posted":"2025-02-05","last_posted":"2025-05-14","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","place_state":"IL","place_scope":"site","site":null,"place_state_source":"sam_zip","place_evidence":null,"place_county":"17031","place_county_name":"Cook County","place_city":null,"place_city_name":null,"winner":"TL SERVICES, INC.","award_amount":"1137659.00","publications":[{"notice_id":"c4beb54ad543492bbd4e1cc3bdb337e7","title":"Z1DA--Install Patient Lifts 578-15-001","solicitation_number":"36C25225B0011","notice_type":"p","base_type":"p","posted":"2025-02-05","posted_at":"2025-02-05T16:47:31.065Z","due_at":"2025-04-01T18:00:00Z","due_date":"2025-04-01","cancelled":false,"archived":true,"archive_date":"2025-05-31","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/c4beb54ad543492bbd4e1cc3bdb337e7/view","enriched":true,"history":[{"index":4,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-05T16:47:31.065Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"c4beb54ad543492bbd4e1cc3bdb337e7","solicitation_number":"36C25225B0011"},{"index":2,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T13:08:29.280Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723","solicitation_number":"36C25225B0011","related_opportunity_id":"c4beb54ad543492bbd4e1cc3bdb337e7"}]},{"notice_id":"264d3d894bfa4a34a47b9cba1b3ba723","title":"Z1DA--Install Patient Lifts 578-15-001","solicitation_number":"36C25225B0011","notice_type":"o","base_type":"p","posted":"2025-02-20","posted_at":"2025-02-20T13:08:29.280Z","due_at":"2025-04-01T18:00:00Z","due_date":"2025-04-01","cancelled":false,"archived":true,"archive_date":"2025-05-31","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/264d3d894bfa4a34a47b9cba1b3ba723/view","enriched":true,"history":[{"index":8,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-05T16:47:31.065Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"c4beb54ad543492bbd4e1cc3bdb337e7","solicitation_number":"36C25225B0011"},{"index":7,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-16T20:07:46.130Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"7160a290accc40f0895cd3f0746a4ce0","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":5,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T19:15:26.849Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ef6048789f184febac3db563950904f9","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":4,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-31T19:45:11.261Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"331d14a464094031b2e75c667369fbe1","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":3,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T17:26:31.797Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"72b2ca4b2b9a4f56a870417eb298d1e7","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":2,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T13:08:29.280Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723","solicitation_number":"36C25225B0011","related_opportunity_id":"c4beb54ad543492bbd4e1cc3bdb337e7"}]},{"notice_id":"72b2ca4b2b9a4f56a870417eb298d1e7","title":"Z1DA--Install Patient Lifts 578-15-001","solicitation_number":"36C25225B0011","notice_type":"o","base_type":"o","posted":"2025-02-20","posted_at":"2025-02-20T17:26:31.797Z","due_at":"2025-04-03T18:00:00Z","due_date":"2025-04-03","cancelled":false,"archived":true,"archive_date":"2025-05-03","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/72b2ca4b2b9a4f56a870417eb298d1e7/view","enriched":true,"history":[{"index":6,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-16T20:07:46.130Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"7160a290accc40f0895cd3f0746a4ce0","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":4,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T19:15:26.849Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ef6048789f184febac3db563950904f9","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":3,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-31T19:45:11.261Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"331d14a464094031b2e75c667369fbe1","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":2,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T17:26:31.797Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"72b2ca4b2b9a4f56a870417eb298d1e7","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":1,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T13:08:29.280Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723","solicitation_number":"36C25225B0011","related_opportunity_id":"c4beb54ad543492bbd4e1cc3bdb337e7"}]},{"notice_id":"331d14a464094031b2e75c667369fbe1","title":"Z1DA--Install Patient Lifts 578-15-001","solicitation_number":"36C25225B0011","notice_type":"o","base_type":"o","posted":"2025-03-31","posted_at":"2025-03-31T19:45:11.261Z","due_at":"2025-04-22T18:00:00Z","due_date":"2025-04-22","cancelled":false,"archived":true,"archive_date":"2025-05-22","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/331d14a464094031b2e75c667369fbe1/view","enriched":true,"history":[{"index":6,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-16T20:07:46.130Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"7160a290accc40f0895cd3f0746a4ce0","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":4,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T19:15:26.849Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ef6048789f184febac3db563950904f9","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":3,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-31T19:45:11.261Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"331d14a464094031b2e75c667369fbe1","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":2,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T17:26:31.797Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"72b2ca4b2b9a4f56a870417eb298d1e7","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":1,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T13:08:29.280Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723","solicitation_number":"36C25225B0011","related_opportunity_id":"c4beb54ad543492bbd4e1cc3bdb337e7"}]},{"notice_id":"ef6048789f184febac3db563950904f9","title":"Z1DA--Install Patient Lifts 578-15-001","solicitation_number":"36C25225B0011","notice_type":"o","base_type":"o","posted":"2025-04-09","posted_at":"2025-04-09T19:15:26.849Z","due_at":"2025-04-22T18:00:00Z","due_date":"2025-04-22","cancelled":false,"archived":true,"archive_date":"2025-05-22","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/ef6048789f184febac3db563950904f9/view","enriched":true,"history":[{"index":6,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-16T20:07:46.130Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"7160a290accc40f0895cd3f0746a4ce0","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":4,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T19:15:26.849Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ef6048789f184febac3db563950904f9","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":3,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-31T19:45:11.261Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"331d14a464094031b2e75c667369fbe1","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":2,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T17:26:31.797Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"72b2ca4b2b9a4f56a870417eb298d1e7","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":1,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T13:08:29.280Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723","solicitation_number":"36C25225B0011","related_opportunity_id":"c4beb54ad543492bbd4e1cc3bdb337e7"}]},{"notice_id":"7160a290accc40f0895cd3f0746a4ce0","title":"Z1DA--Install Patient Lifts 578-15-001","solicitation_number":"36C25225B0011","notice_type":"o","base_type":"o","posted":"2025-04-16","posted_at":"2025-04-16T20:07:46.130Z","due_at":"2025-04-22T18:00:00Z","due_date":"2025-04-22","cancelled":false,"archived":true,"archive_date":"2025-05-22","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/7160a290accc40f0895cd3f0746a4ce0/view","enriched":true,"history":[{"index":9,"title":"Z1DA--578-15-001 Install Patient Lifts - Construction Multiple Locations","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-05-14T20:27:35.306Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"56f81639de004abca4d1aff26fa44595","solicitation_number":"36C25225B0011","related_opportunity_id":"7160a290accc40f0895cd3f0746a4ce0"},{"index":7,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-16T20:07:46.130Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"7160a290accc40f0895cd3f0746a4ce0","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":4,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T19:15:26.849Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ef6048789f184febac3db563950904f9","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":3,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-31T19:45:11.261Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"331d14a464094031b2e75c667369fbe1","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":2,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T17:26:31.797Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"72b2ca4b2b9a4f56a870417eb298d1e7","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":1,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T13:08:29.280Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723","solicitation_number":"36C25225B0011","related_opportunity_id":"c4beb54ad543492bbd4e1cc3bdb337e7"}]},{"notice_id":"56f81639de004abca4d1aff26fa44595","title":"Z1DA--578-15-001 Install Patient Lifts - Construction Multiple Locations","solicitation_number":"36C25225B0011","notice_type":"a","base_type":"o","posted":"2025-05-14","posted_at":"2025-05-14T20:27:35.306Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2025-06-13","removed_at":null,"award_number":"36C25225C0035","awardee_name":"TL Services, Inc.","amount":"1137659.00","link_sam":"https://sam.gov/workspace/contract/opp/56f81639de004abca4d1aff26fa44595/view","enriched":true,"history":[{"index":5,"title":"Z1DA--578-15-001 Install Patient Lifts - Construction Multiple Locations","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-05-14T20:27:35.306Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"56f81639de004abca4d1aff26fa44595","solicitation_number":"36C25225B0011","related_opportunity_id":"7160a290accc40f0895cd3f0746a4ce0"},{"index":3,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-16T20:07:46.130Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"7160a290accc40f0895cd3f0746a4ce0","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"}]}],"latest_notice_id":"56f81639de004abca4d1aff26fa44595","first_type":"p","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-02-05","posted_at":"2025-02-05T16:47:31.065Z","created_at":"2025-02-05T16:47:28.882Z","modified_at":"2025-06-01T03:55:49.720Z","response_deadline":{"raw":"2025-04-01T13:00:00-05:00","utc":"2025-04-01T18:00:00Z","date":"2025-04-01","time":"13:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/c4beb54ad543492bbd4e1cc3bdb337e7/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z1DA--Install Patient Lifts 578-15-001","agency":{"office":{"code":"36C252","name":"252-NETWORK CONTRACT OFFICE 12 (36C252)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"53214","city":"MILWAUKEE","state":"WI","country":"USA"},"organization_id":"100180018","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-05-31","archive_type":"auto_custom"},"history":[{"index":4,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-05T16:47:31.065Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"c4beb54ad543492bbd4e1cc3bdb337e7","solicitation_number":"36C25225B0011"},{"index":2,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T13:08:29.280Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723","solicitation_number":"36C25225B0011","related_opportunity_id":"c4beb54ad543492bbd4e1cc3bdb337e7"}],"contacts":[{"fax":"414-844-4800","name":"Donita Grace","role":"primary","email":"donita.grace@va.gov","phone":"414-844-4800","title":"Contract Specialist"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"c4beb54ad543492bbd4e1cc3bdb337e7","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"264d3d894bfa4a34a47b9cba1b3ba723","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-23T04:05:43.302041608Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"80fac907270d66a0402d2af75a679163722fe260e9f8a9868c6ad254aa52da4e","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-23T04:05:43.302041608Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Solicitation 36C25225B0011\n\nProject:  578-15-001 Install Patient Lifts in Multiple Locations\n\nLocation: Edward Hines Jr. VAMC\n5000 5th Ave. \nHines, IL 60141\n \nThis construction project involves installation of permanent, ceiling-mounted, patient lifts in Buildings 1, 8, 12, 113, 128, 200, 217, and 228. The patient lifts requirements are specific to each location. The lifts must meet the requirements specified in the salient characteristics identified in the design drawing and specifications. All measurements & dimensions submitted to the Contractor are approximate. The Contractor must verify all measurements & dimensions.\nThe Contractor shall inspect the area under contract prior to commencing work and identify any pre-existing damage and provide an Existing Site Conditions report with related photos to the Contracting Officer for review and approval.  \n\nPeriod of Performance is 432 calendar days after Notice to Proceed (NTP).  The NTP shall be issued approximately 14 calendar days after award once required payment and performance bonds and certificate of insurance is provided.  \nThe North American Industry Classification Code (NAICS) for this procurement is 236220 Commercial and Institutional Building Construction; small business $45.0 million size standard applies.  \nEstimated price range for construction is between $2,000,000 and $5,000,000.   \nPursuant to Public Law 109-461, this solicitation is set-aside for Service-Disabled Veteran-Owned Small Business (SDVOSB) firms.  In accordance with VAAR 819.7003(b), at the time of submission of bids, and prior to award of any contracts, the offeror must represent to the contracting officer that it is a \n\n(1) SDVOSB eligible vendor IAW VAAR Subpart 819.70; https://www.va.gov/oal/library/vaar/vaar819.asp#8197001 \n(2) Small business concern under the NAICS code assigned to this acquisition; and \n(3) SDVOSB listed as verified in SBA VIP database at:Â  https://veterans.certify.sba.gov/\n\nThe solicitation, specifications and drawings will be posted on https://sam.gov/content/opportunities\nbetaSAM.gov   CONTRACTING OPPORTUNTIES on, or about February 20, 2025.  A pre-bid site conference and a site walk-through for this solicitation is tentatively scheduled for the week of March 6, 2025 (exact time and location shall be provided with the formal solicitation package).  All interested offerors, subcontractors and suppliers are strongly encouraged to attend.  \n\nVendors are responsible to monitor and download the solicitation and any amendments associated with this solicitation from https://sam.gov/content/opportunities\n    \n\nPoint of Contact: Donita Grace   donita.grace@va.gov.","text":"Solicitation 36C25225B0011\n\nProject: 578-15-001 Install Patient Lifts in Multiple Locations\n\nLocation: Edward Hines Jr. VAMC\n5000 5th Ave.\nHines, IL 60141\n\nThis construction project involves installation of permanent, ceiling-mounted, patient lifts in Buildings 1, 8, 12, 113, 128, 200, 217, and 228. The patient lifts requirements are specific to each location. The lifts must meet the requirements specified in the salient characteristics identified in the design drawing and specifications. All measurements & dimensions submitted to the Contractor are approximate. The Contractor must verify all measurements & dimensions.\nThe Contractor shall inspect the area under contract prior to commencing work and identify any pre-existing damage and provide an Existing Site Conditions report with related photos to the Contracting Officer for review and approval.\n\nPeriod of Performance is 432 calendar days after Notice to Proceed (NTP). The NTP shall be issued approximately 14 calendar days after award once required payment and performance bonds and certificate of insurance is provided.\nThe North American Industry Classification Code (NAICS) for this procurement is 236220 Commercial and Institutional Building Construction; small business $45.0 million size standard applies.\nEstimated price range for construction is between $2,000,000 and $5,000,000.\nPursuant to Public Law 109-461, this solicitation is set-aside for Service-Disabled Veteran-Owned Small Business (SDVOSB) firms. In accordance with VAAR 819.7003(b), at the time of submission of bids, and prior to award of any contracts, the offeror must represent to the contracting officer that it is a\n\n(1) SDVOSB eligible vendor IAW VAAR Subpart 819.70; https://www.va.gov/oal/library/vaar/vaar819.asp#8197001\n(2) Small business concern under the NAICS code assigned to this acquisition; and\n(3) SDVOSB listed as verified in SBA VIP database at:Â https://veterans.certify.sba.gov/\n\nThe solicitation, specifications and drawings will be posted on https://sam.gov/content/opportunities\nbetaSAM.gov CONTRACTING OPPORTUNTIES on, or about February 20, 2025. A pre-bid site conference and a site walk-through for this solicitation is tentatively scheduled for the week of March 6, 2025 (exact time and location shall be provided with the formal solicitation package). All interested offerors, subcontractors and suppliers are strongly encouraged to attend.\n\nVendors are responsible to monitor and download the solicitation and any amendments associated with this solicitation from https://sam.gov/content/opportunities\n\nPoint of Contact: Donita Grace donita.grace@va.gov.","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"36C25225B0011","place_of_performance":{"zip":"60141","city":{"name":"Hines, IL"},"country":{"code":"USA","name":"UNITED STATES"},"street2":"Edward Hines Jr. VA Hospital 5000 5th Ave"},"product_service_code":"Z1DA"},{"award":{"awardee":{}},"dates":{"posted":"2025-02-20","posted_at":"2025-02-20T13:08:29.280Z","created_at":"2025-02-20T13:07:55.813Z","modified_at":"2025-05-23T04:04:31.756Z","response_deadline":{"raw":"2025-04-01T13:00:00-05:00","utc":"2025-04-01T18:00:00Z","date":"2025-04-01","time":"13:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/264d3d894bfa4a34a47b9cba1b3ba723/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z1DA--Install Patient Lifts 578-15-001","agency":{"office":{"code":"36C252","name":"252-NETWORK CONTRACT OFFICE 12 (36C252)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"53214","city":"MILWAUKEE","state":"WI","country":"USA"},"organization_id":"100180018","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-05-31","archive_type":"auto_custom"},"history":[{"index":8,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-05T16:47:31.065Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"c4beb54ad543492bbd4e1cc3bdb337e7","solicitation_number":"36C25225B0011"},{"index":7,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-16T20:07:46.130Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"7160a290accc40f0895cd3f0746a4ce0","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":5,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T19:15:26.849Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ef6048789f184febac3db563950904f9","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":4,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-31T19:45:11.261Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"331d14a464094031b2e75c667369fbe1","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":3,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T17:26:31.797Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"72b2ca4b2b9a4f56a870417eb298d1e7","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":2,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T13:08:29.280Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723","solicitation_number":"36C25225B0011","related_opportunity_id":"c4beb54ad543492bbd4e1cc3bdb337e7"}],"contacts":[{"name":"Donita L Grace","role":"primary","email":"donita.grace@va.gov","title":"Contractor"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"264d3d894bfa4a34a47b9cba1b3ba723","lineage_id":"264d3d894bfa4a34a47b9cba1b3ba723","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-22T03:37:32.564404570Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"1bb1e58a16c059f0c3ba534c98763d4ba708d0e253ce1a8faf98366cee0cefd2","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-22T03:37:32.564404570Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"ATTACHMENTS","text":"ATTACHMENTS","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C25225B0011","product_service_code":"Z1DA"},{"award":{"awardee":{}},"dates":{"posted":"2025-02-20","posted_at":"2025-02-20T17:26:31.797Z","created_at":"2025-02-20T17:26:30.149Z","modified_at":"2025-05-23T04:04:31.756Z","response_deadline":{"raw":"2025-04-03T13:00:00-05:00","utc":"2025-04-03T18:00:00Z","date":"2025-04-03","time":"13:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/72b2ca4b2b9a4f56a870417eb298d1e7/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z1DA--Install Patient Lifts 578-15-001","agency":{"office":{"code":"36C252","name":"252-NETWORK CONTRACT OFFICE 12 (36C252)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"53214","city":"MILWAUKEE","state":"WI","country":"USA"},"organization_id":"100180018","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-05-03","archive_type":"auto_custom"},"history":[{"index":6,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-16T20:07:46.130Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"7160a290accc40f0895cd3f0746a4ce0","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":4,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T19:15:26.849Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ef6048789f184febac3db563950904f9","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":3,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-31T19:45:11.261Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"331d14a464094031b2e75c667369fbe1","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":2,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T17:26:31.797Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"72b2ca4b2b9a4f56a870417eb298d1e7","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":1,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T13:08:29.280Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723","solicitation_number":"36C25225B0011","related_opportunity_id":"c4beb54ad543492bbd4e1cc3bdb337e7"}],"contacts":[{"name":"Donita L Grace","role":"primary","email":"donita.grace@va.gov","title":"Contractor"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"72b2ca4b2b9a4f56a870417eb298d1e7","lineage_id":"264d3d894bfa4a34a47b9cba1b3ba723","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-22T03:51:22.660475311Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"1ba7cfbeb3c14c6f9518a8fe13741b9c6c39e7ee6571910225440f148a410dd4","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-22T03:51:22.660475311Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"SOLICITATION 36C25225B0011\nAMENDMENT A0001\nFebruary 20, 2025\n\nProject: Install Patient Lifts\nProject Number: \nLocation: Edward Hines Jr. VA Hospital\n\nAmendment 0001 hereby incorporates the following clarifications/change(s) into the solicitation package.\n\nSite Visit Time\n\nSITE VISIT: 8:00A.M.   4:00 P.M.\nThe pre-bid conference will occur on Wednesday, March 5, 2025 CST.Â  \nThe location is at the Edward Hines Jr. VA Hospital, 5000 S. Fifth Avenue Hines, IL 610141Â Â  \nAll participants will meet the Contracting Officer Representative (COR) at Room 126, Bldg. 2 (Bldg. with Clock tower). \n\nDue to the multiple locations throughout Hines Campus, expect the Site Visit to encompass the entire day.\n\n \n\n\nProposal Due DATE / TIME: April 3, 2025, at 1:00 p.m. CST.   \n \nALL QUESTIONS REGARDING THIS SOLICITATION SHALL BE SENT TO THE FOLLOWING INDIVIDUALS:\nDonita Grace -- Donita.Grace@va.gov\n\nThis solicitation can be monitored on the Vendor Portal.\n\nContractors shall ensure all amendments are acknowledged on Page 2 of the SF-1442.","text":"SOLICITATION 36C25225B0011\nAMENDMENT A0001\nFebruary 20, 2025\n\nProject: Install Patient Lifts\nProject Number:\nLocation: Edward Hines Jr. VA Hospital\n\nAmendment 0001 hereby incorporates the following clarifications/change(s) into the solicitation package.\n\nSite Visit Time\n\nSITE VISIT: 8:00A.M. 4:00 P.M.\nThe pre-bid conference will occur on Wednesday, March 5, 2025 CST.Â\nThe location is at the Edward Hines Jr. VA Hospital, 5000 S. Fifth Avenue Hines, IL 610141Â Â\nAll participants will meet the Contracting Officer Representative (COR) at Room 126, Bldg. 2 (Bldg. with Clock tower).\n\nDue to the multiple locations throughout Hines Campus, expect the Site Visit to encompass the entire day.\n\nProposal Due DATE / TIME: April 3, 2025, at 1:00 p.m. CST.\n\nALL QUESTIONS REGARDING THIS SOLICITATION SHALL BE SENT TO THE FOLLOWING INDIVIDUALS:\nDonita Grace -- Donita.Grace@va.gov\n\nThis solicitation can be monitored on the Vendor Portal.\n\nContractors shall ensure all amendments are acknowledged on Page 2 of the SF-1442.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C25225B0011","product_service_code":"Z1DA"},{"award":{"awardee":{}},"dates":{"posted":"2025-03-31","posted_at":"2025-03-31T19:45:11.261Z","created_at":"2025-03-31T19:45:09.480Z","modified_at":"2025-05-23T04:04:31.756Z","response_deadline":{"raw":"2025-04-22T13:00:00-05:00","utc":"2025-04-22T18:00:00Z","date":"2025-04-22","time":"13:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/331d14a464094031b2e75c667369fbe1/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z1DA--Install Patient Lifts 578-15-001","agency":{"office":{"code":"36C252","name":"252-NETWORK CONTRACT OFFICE 12 (36C252)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"53214","city":"MILWAUKEE","state":"WI","country":"USA"},"organization_id":"100180018","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-05-22","archive_type":"auto_custom"},"history":[{"index":6,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-16T20:07:46.130Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"7160a290accc40f0895cd3f0746a4ce0","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":4,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T19:15:26.849Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ef6048789f184febac3db563950904f9","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":3,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-31T19:45:11.261Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"331d14a464094031b2e75c667369fbe1","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":2,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T17:26:31.797Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"72b2ca4b2b9a4f56a870417eb298d1e7","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":1,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T13:08:29.280Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723","solicitation_number":"36C25225B0011","related_opportunity_id":"c4beb54ad543492bbd4e1cc3bdb337e7"}],"contacts":[{"name":"Donita L Grace","role":"primary","email":"donita.grace@va.gov","title":"Contractor"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"331d14a464094031b2e75c667369fbe1","lineage_id":"264d3d894bfa4a34a47b9cba1b3ba723","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-19T10:03:39.596387187Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"82f745d2ccb7b66756f89d690fd55b5f2b27b42331e377f84e2abe041944600b","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-19T10:03:39.596387187Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Continuation Page","text":"Continuation Page","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C25225B0011","product_service_code":"Z1DA"},{"award":{"awardee":{}},"dates":{"posted":"2025-04-09","posted_at":"2025-04-09T19:15:26.849Z","created_at":"2025-04-09T19:15:24.812Z","modified_at":"2025-05-23T04:04:31.756Z","response_deadline":{"raw":"2025-04-22T13:00:00-05:00","utc":"2025-04-22T18:00:00Z","date":"2025-04-22","time":"13:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/ef6048789f184febac3db563950904f9/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z1DA--Install Patient Lifts 578-15-001","agency":{"office":{"code":"36C252","name":"252-NETWORK CONTRACT OFFICE 12 (36C252)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"53214","city":"MILWAUKEE","state":"WI","country":"USA"},"organization_id":"100180018","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-05-22","archive_type":"auto_custom"},"history":[{"index":6,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-16T20:07:46.130Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"7160a290accc40f0895cd3f0746a4ce0","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":4,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T19:15:26.849Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ef6048789f184febac3db563950904f9","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":3,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-31T19:45:11.261Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"331d14a464094031b2e75c667369fbe1","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":2,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T17:26:31.797Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"72b2ca4b2b9a4f56a870417eb298d1e7","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":1,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T13:08:29.280Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723","solicitation_number":"36C25225B0011","related_opportunity_id":"c4beb54ad543492bbd4e1cc3bdb337e7"}],"contacts":[{"name":"Donita L Grace","role":"primary","email":"donita.grace@va.gov","title":"Contractor"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"ef6048789f184febac3db563950904f9","lineage_id":"264d3d894bfa4a34a47b9cba1b3ba723","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-18T04:03:42.520242956Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"4883e0a833e9e2eb7dfb998282a3bf168d3e777f482d7fbca1e4db1d2383eeb2","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-18T04:03:42.520242956Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Project: Install Patient LiftsSOLICITATION 36C25225B0011April 7, 2025\nProject #: 578-15-001 AMENDMENT A0003 Edward Hines Jr. VAMC\n\n\nAmendment 0003 hereby incorporates the following clarifications/change(s) into the solicitation package.\n\nRFI s Questions and Responses\n\nÂ \nCONTRACTOR QUESTIONS\nREFERENCE\nVA/AE RESPONSE\n1\nThe cover sheet list that there should be a E604 Panel Schedule, the last drawing I have is E603. Is this something that needs to be issued or was it an error?\nÂ \nA/E - Remove all references to E604. Sheet was removed during the design process\n1\nPanel Schedule LL-ICU-A-R indicates the panel is in room B2039. The electrical room number on sheet E120 indicates the panel is in room A2071. Which is correct?\nE120\nPanel LL-ICU-A-R is located in room A701. The panel schdeule (located on E602) will be updated to properly refect the floorplan.\n2\nPanel Schedule LL-10B-R on sheet E603 has the location for the panel as room RCC1003R. Where is this indicated on the electrical drawings and what lifts do they serve?\nE603\nBuilding 200 10th floor. See sheet E127\n3\nPanel Schedule LL-11B-R on sheet E603 has the location for the panel as room RCC1003R. Where is this indicated on the electrical drawings and what lifts do they serve?\nE603\nBuilding 200 11th floor. See sheet E130. Room number on panel schedule will be updated to \"1171\" to reflect the floorplan.\n4\nE130 indicates that the lift power for room 1134 routes to the electrical panel LL-11B-R. It appears the panel is located in the adjacent room 1171. Can the VA confirm which room that panel LL-11B-R is actually located in?\nE130\nPanel LL-11B-R is located in toom \"1171\". The panel schdeule (located on E602) will be updated to properly refect the floorplan.\n5\nAn Electrical Sheet appears to be missing for Bldg 228- 5th floor reflecting which room lifts go to which circuits in panel 5L3 and that panel s location within the electrical room. Can this information be provided on the drawings?\nBldg 228-5\nPanel 5L3 is shown on sheet E136.\n6\nElectrical Sheet appears to be missing for Bldg 228- Basement floor reflecting the existing panel location within the electrical room B1014 panel BL2. Can this information be provided on the drawings?\nÂ \nPanel BL2 is shown on sheet E134.\n7\nElectrical Sheet appears to be missing for Bldg 200- 13th floor reflecting the existing panel location within the electrical room 1387B panel LL-13B-R. Can this information be provided on the drawings?\nÂ \nPanel LL-13B-R is shown on sheet E132.\n8\nElectrical Sheet appears to be missing for Bldg 200- 11th floor reflecting the existing electrical room, panel and panel location within the electrical room for room 1134. Can this information be provided on the drawings?\nÂ \nSee sheet E130 for the location on panel that serves room 1134.\n9\nSeveral locations have notes stating to cut open the hard ceiling in order to install the lift supports. The areas hatched appear to be 2 x2  square. Are we to assume that 2 x2  openings are all that is required to be cut and patched at each location shown or is that to be determined by the contractor?\nÂ \nRefer to General Electrical Notes AA, BB located on E001 for information regarding cutting and patching. Contractor is determine existing ceiling conditions for cutting and patching requirements.\n10\nIs the basis of design for the new lift manufacturer the only lifts the VA will accept or can other manufacturers be submitted?\nÂ \nThe Lift Manufacturer identified is the VA's preferred vendor/lift.  However, manufacturers who have equipment that have specifications above and beyond the specifications of the \"basis of design\" equipment are acceptable and will be considered.\n11\nCan the VA confirm that of all the new lifts required, that there are only three (3)  existing lifts  that need to be removed and replaced with new ones?\nÂ \nTwo lifts need to be replaced - (1) lift in Bldg 1 G201 and (1) in Bldg 128. There is a cross rail in Bldg 128 with no lift attached that may be causing confusion.\n12\nThe drawings appear to have been plotted as an image rather than to a true PDF. Can the drawing be provided in true PDF format?\nÂ \n Available upon award.\n13\nThis paragraph lists bariatric lifts 750-1000lbs. Drawing sheet GI0001 reflects 1 each bariatric lift. However, drawings for CLC - 1C PATIENT ROOM1C152 also reflect 1 each bariatric lift. Can the VA confirm that there are only 2 each bariatric lifts and the Lifting Capacity required for each of them?\nSpecification Section 11 73 00 - Ceiling Mounted Patient Lift, para 2.2 LIFT UNIT \nFollow the capacity per Spec section 117300 2.2\n14\nThis para references   600-pound capacity lifts unless noted otherwise.  Section 11 73 00 para 2.2 LIFT UNIT states  Lifting capacity: 550 lbs (249.476 kg) for non-bariatric lifts.  Can the VA clarify which is correct for the non-bariatric lifts?\n010000 GENERAL REQUIREMENTS, para 1.3 STATEMENT OF BID ITEM(S)  B \nFollow the capacity per Spec section 117300 2.2\n15\nThis section specifies the Basis of Design is the Handi-Care. Is the VA going to issue a sole source justification for Handi-Care or are other manufacturers acceptable?\nSpecification Section 11 73 00 - Ceiling Mounted Patient Lift, para 1.1 DESCRIPTION\nThe Lift Manufacturer identified is the VA's preferred vendor/lift.  However, manufacturers who have equipment that have specifications above and beyond the specifications of the \"basis of design\" equipment are acceptable and will be considered.\n16\nThis para references VA installation checklist (Patient Safety Alert AL14-07). It appears this alert is not on the VA TIL website. Can the VA provide this document?\nSpecification Section 11 73 00 - Ceiling Mounted Patient Lift, para 3.4 INSPECTION\nSee attached\n17\nThis para references Periodic Inspection shall be provided by the manufacturer on a yearly basis in compliance with ISO 10535. Can the VA provide what the expectations are for inspection post completion/acceptance of the project?\nSpecification Section 11 73 00 - Ceiling Mounted Patient Lift, para 3.4 INSPECTION\nVA to provide annual inspections.  See Project Manual Section 11 73 00 Part 1.3 Quality Assurance for project completion/acceptance requirements.\n18\nCan the VA provide the current life safety drawings for each of the buildings to include drawing that indicate both smoke and fire rated walls?\nÂ \nAvailable upon award.\n19\n Can the VA clarify where panelboards are to be installed?\nSection 26 24 16 PANELBOARDS was included in the specifications.\nSee electrical drawings for panel locations\n20\nThis para states  Each room to receive new patient lifts shall be considered a   Phase . The work shall be done one phase(room) at a time.  Whereas the Patient Lift Locations table reflects multiple rooms under a single phase. Can the VA clarify if each room is a phase, or the rooms shown in the table the correct phasing?\nSection 010000 GENERAL REQUIREMENTS, para I. Phasing \nEach Building to be completed in entireity prior to starting an additional building. See table for the work hours and amount of rooms to be worked at 1 time. \n21\nThis para states   the Contractor shall submit and receive approval for an accepted Submittal Registry.  Pages 40   47 of the specification contains a Submittal Registry. Can the VA confirm that this is the Submittal Registry for the project or can software such as Procore be used?\nSection 010000 GENERAL REQUIREMENTS, para 1.11 SUBMITTAL REGISTRY\nContractor must develop a submittal registry including anticipated submittal dates. Contractor to utilize a Construction Administration software. \n22\nWhat is the VA review period that we should expect for submitted RFIs ?\nSection 010000 GENERAL REQUIREMENTS, para 1.12 REQUESTS FOR INFORMATION\n7 days for RFIs and 15 days for Submittals\n23\nCan the VA confirm that the project schedule has to be cost loaded?\nSection 013216-15 PROJECT SCHEDULES, para 1.6 WORK ACTIVITY/EVENT COST DATA\nYes, cost loading required.\n24\nCan the VA confirm that if detail 2/A502 welding is required, is the VA ok with welding above ceiling within the hospital?\nÂ \nComply with Welding permit regulations.\n25\nDetail 2/A502 reflects Unistrut attached to the top chord of the joist, whereas detail 7/a502 reflects connection at the bottom chord. Which is correct?\nÂ \nDetail 2 provides guidance on when this condition is to be implemented. \n26\nThis enlarged plan reflects section 2 for both views. Should they reference details 1 & 2/501?\nDrawing Sheet A115, ENLARGED PLAN 1B175\nYes, both Details apply.\n27\nCan the VA confirm that this is a drywall ceiling in this area and the contractor is to cut access into the ceiling, as there are no demolition notes on the sheet?\n Drawing Sheet A124, ENLARGED PLAN 725\nDrywall ceiling to be modified as necessary to mount new ceiling lift.\n28\nCan the VA confirm that this is a drywall ceiling in this area and the contractor is to cut access into the ceiling, as there are no demolition notes on the sheet?\nDrawing Sheet A124, ENLARGED PLAN 721\nDrywall ceiling to be modified as necessary to mount new ceiling lift.\n29\nThis sheet does not indicate which sections are applicable to the space, IE details on A501 that would indicate the type of structure above?\nDrawing Sheet A135, ENLARGED PLAN B1025\nRefer to Sheet A501 Detail 2.\n30\nCan the VA please provide existing finished ceiling heights for all rooms?\nÂ \nBuilding 12, Building 217(level 2) Ceiling: 10', Building 113,128,217 (level 1), Room B1-2-G226, Room B8- 1- 106R, Building 200 ( basement, level 1, level 2) Ceiling: 9', Building 200 level 7 ceiling: 10' 0'', Building 200 (room 709,716) Building 200 (level 10,11,13) ceiling: 9' 0'', Building 228 ceiling: 9' 3''\n31\n Can the VA provide the floor to deck height in each room?\nÂ \nB1-3-D355, B1-2-G201,B1-2-G226, Building 228 Level 5, Floor to Floor: 13'. Building 12 : 11'8''. Building 113, 217 (level 1) and 228 basement 13' 8''. Building 217 level 2 Floor to Roof 14'.Building 200 basement 13' 9''. Building 200 level 1 12' 5''. Building 200 level 2 11' 9''. Building 200 level 7, 10,11,13:  11' 3''.\n32\nCan the VA provide the manufacture of the existing Cubicle Curtain Tracks that are to be extended and or modified?\nÂ \nExisting tracks are Medcare.\n33\nCan the VA provide the manufacture of any new Cubicle Curtain Tracks that are required?\nÂ \nFollow Project Manual Bid Specifications Section 10 21 23 (Attachment 2).\n34\nCan the VA confirm that Cubicle Curtains are VA furnished/ VA installed?\nÂ \nVA furnishes and installs track curtains.\n35\nPlease clarify that if there are ducts, electrical or any other service in that would prohibit the installation of a given lift based on the locations shown, that each instance would be worked out as a change in condition?\nÂ \nGC to make every effort to install lifts as designed. Unforseen conditions will be addressed as they arise.\n36\nThe bid schedule has 60 lifts indicated, whoever the lft schedule reflects 58. Can the VA clarify if 60 lifts are required or 58?\nÂ \nProvide 61 Lifts. The (1) lift in Bldg 128 Room A100 can be considered to be used in one of the single track installation locations, which would then make the total 60.\n1\nPlease confirm the SSHO duties can be fulfilled by the prime contractor superintendent. \nReference: 013526 Safety Spec   SSHO\nYes, this is acceptable\n2\nPlease verify that firestop needs to be installed by a firm that has been approved by FM Global? Or can firestop be installed by installers who hold a manufacturer s certification such as Hilti or 3M?\n078400 Firestop   Quality Assurance\nFirestop needs to meet the requirements of the wall.  Any of the three mentioned installers are acceptable.\n3\nPlease verify that firestop inspections are required as part of this contract. \n078400 Firestop   Quality Assurance\nContractor to provide Quality control.  VA will provide inspection.\n4\nPlease verify the designated contractor laydown area for this project. Will construction fencing be required around job trailer, storage unit, and construction dumpster?\nContractor Laydown/Storage\nAvailable upon award.\n5\nWill the owner move or relocate existing furniture/equipment in rooms prior to construction?\nOwner furniture/EquipmentÂ Â Â Â Â Â Â Â Â Â Â Â Â  \nContractor to relocate existing furniture with coordination from COR.\n1\nPlease confirm that the owner is applying and paying for the building permit or should we carry an allowance for this.\nGeneral\nBuilding Permits are not required on Federal Property.\n2\nBased on ICRA documentation, level II containment cannot be used for high-risk group type B projects.  Please confirm the level 2 designation on Sheet GI001 for the high-risk type B projects is correct.\nÂ \nDesignation is correct and approved by Infection Control.\n3\nPlease confirm if we need to fireproof/ fire spray the steel in the ambulance area\nÂ \nNot Required\n4\nWe understand that there are some restrictions as to the number of rooms that we can work on at any one time on a floor but please confirm whether we are restricted from working in rooms on multiple floors at the same time.\nÂ \nNo restrictions on working on multiple floors as long as the Construction schedule is followed.\n5\nShould we include time for punch lists for each room.  If so, please confirm how many days.\nÂ \nAE recommends 1 punch per building to set standards.  COR recommends 1 hour/lift.\n6\nPlease provide a site plan for each building for staging our dumpsters\nÂ \nVA to provide guidance on Contractor Staging Areas during Pre-Construction phase.\n7\nPlease confirm hangers for the track for the patient lift interfere with the ACT grid and lights like B1025 where the track and hangers are drawn penetrating the ACT grid.  Please specify how you would like us to proceed.\n095100   Acoustical Ceilings\nAdjust ceiling track layout to avoid existing conditions\n8\nPlease confirm that the replacement of the existing ACT tile and grid is not included in our scope of work.\nÂ \nGC to confirm ACT ceiling prior to work and replace damaged ACT and Grid\n9\nPlease provide building standards for ACT tiles and grid specifications for existing material.\nÂ \nStandard Room - ARMSTRONG Ceiling Tile: 1910A, 24 in x 24 in, Square Lay-In, 15/16 in Grid Size, 0.75 NRC, 12 PK or ARMSTRONG Ceiling Tile: 1721B, 24 in x 48 in, Square Lay-In, 15/16 in Grid Size, 0.55 NRC, 8 PK\nCleanroom - ARMSTRONG Ceiling Tile: 1720B, 24 in x 24 in, Square Lay-In, 15/16 in Grid Size, 0.55 NRC, 12 PK\n10\nPlease provide building standards for paint colors of doors, frames, walls and ceilings.\n099000   Painting\nIf any doors, walls, or frames need painting, contractors need to match existing.\nFor ceilings, Hines VA prefers Benjamin Moore Flat Ceiling White.\n11\nPlease confirm whether we are to bid for a continuous charging system or a docking station for charging the lift equipment.\n110000   Equipment\nDocking Station is the bidding option\n\n\n\nRFI Attachment (Att1)\nS06   VA Alert 14-07 \n\n \n \n\n\nProposal Due DATE / TIME: April 22, 2025, at 1:00 p.m. CST.   \n \nALL QUESTIONS REGARDING THIS SOLICITATION SHALL BE SENT TO THE FOLLOWING INDIVIDUALS:\nDonita Grace -- Donita.Grace@va.gov\n\nThis solicitation can be monitored on the Vendor Portal.\n\nContractors shall ensure all amendments are acknowledged on Page 2 of the SF-1442.","text":"Project: Install Patient LiftsSOLICITATION 36C25225B0011April 7, 2025\nProject #: 578-15-001 AMENDMENT A0003 Edward Hines Jr. VAMC\n\nAmendment 0003 hereby incorporates the following clarifications/change(s) into the solicitation package.\n\nRFI s Questions and Responses\n\nÂ\nCONTRACTOR QUESTIONS\nREFERENCE\nVA/AE RESPONSE\n1\nThe cover sheet list that there should be a E604 Panel Schedule, the last drawing I have is E603. Is this something that needs to be issued or was it an error?\nÂ\nA/E - Remove all references to E604. Sheet was removed during the design process\n1\nPanel Schedule LL-ICU-A-R indicates the panel is in room B2039. The electrical room number on sheet E120 indicates the panel is in room A2071. Which is correct?\nE120\nPanel LL-ICU-A-R is located in room A701. The panel schdeule (located on E602) will be updated to properly refect the floorplan.\n2\nPanel Schedule LL-10B-R on sheet E603 has the location for the panel as room RCC1003R. Where is this indicated on the electrical drawings and what lifts do they serve?\nE603\nBuilding 200 10th floor. See sheet E127\n3\nPanel Schedule LL-11B-R on sheet E603 has the location for the panel as room RCC1003R. Where is this indicated on the electrical drawings and what lifts do they serve?\nE603\nBuilding 200 11th floor. See sheet E130. Room number on panel schedule will be updated to \"1171\" to reflect the floorplan.\n4\nE130 indicates that the lift power for room 1134 routes to the electrical panel LL-11B-R. It appears the panel is located in the adjacent room 1171. Can the VA confirm which room that panel LL-11B-R is actually located in?\nE130\nPanel LL-11B-R is located in toom \"1171\". The panel schdeule (located on E602) will be updated to properly refect the floorplan.\n5\nAn Electrical Sheet appears to be missing for Bldg 228- 5th floor reflecting which room lifts go to which circuits in panel 5L3 and that panel s location within the electrical room. Can this information be provided on the drawings?\nBldg 228-5\nPanel 5L3 is shown on sheet E136.\n6\nElectrical Sheet appears to be missing for Bldg 228- Basement floor reflecting the existing panel location within the electrical room B1014 panel BL2. Can this information be provided on the drawings?\nÂ\nPanel BL2 is shown on sheet E134.\n7\nElectrical Sheet appears to be missing for Bldg 200- 13th floor reflecting the existing panel location within the electrical room 1387B panel LL-13B-R. Can this information be provided on the drawings?\nÂ\nPanel LL-13B-R is shown on sheet E132.\n8\nElectrical Sheet appears to be missing for Bldg 200- 11th floor reflecting the existing electrical room, panel and panel location within the electrical room for room 1134. Can this information be provided on the drawings?\nÂ\nSee sheet E130 for the location on panel that serves room 1134.\n9\nSeveral locations have notes stating to cut open the hard ceiling in order to install the lift supports. The areas hatched appear to be 2 x2 square. Are we to assume that 2 x2 openings are all that is required to be cut and patched at each location shown or is that to be determined by the contractor?\nÂ\nRefer to General Electrical Notes AA, BB located on E001 for information regarding cutting and patching. Contractor is determine existing ceiling conditions for cutting and patching requirements.\n10\nIs the basis of design for the new lift manufacturer the only lifts the VA will accept or can other manufacturers be submitted?\nÂ\nThe Lift Manufacturer identified is the VA's preferred vendor/lift. However, manufacturers who have equipment that have specifications above and beyond the specifications of the \"basis of design\" equipment are acceptable and will be considered.\n11\nCan the VA confirm that of all the new lifts required, that there are only three (3) existing lifts that need to be removed and replaced with new ones?\nÂ\nTwo lifts need to be replaced - (1) lift in Bldg 1 G201 and (1) in Bldg 128. There is a cross rail in Bldg 128 with no lift attached that may be causing confusion.\n12\nThe drawings appear to have been plotted as an image rather than to a true PDF. Can the drawing be provided in true PDF format?\nÂ\nAvailable upon award.\n13\nThis paragraph lists bariatric lifts 750-1000lbs. Drawing sheet GI0001 reflects 1 each bariatric lift. However, drawings for CLC - 1C PATIENT ROOM1C152 also reflect 1 each bariatric lift. Can the VA confirm that there are only 2 each bariatric lifts and the Lifting Capacity required for each of them?\nSpecification Section 11 73 00 - Ceiling Mounted Patient Lift, para 2.2 LIFT UNIT\nFollow the capacity per Spec section 117300 2.2\n14\nThis para references 600-pound capacity lifts unless noted otherwise. Section 11 73 00 para 2.2 LIFT UNIT states Lifting capacity: 550 lbs (249.476 kg) for non-bariatric lifts. Can the VA clarify which is correct for the non-bariatric lifts?\n010000 GENERAL REQUIREMENTS, para 1.3 STATEMENT OF BID ITEM(S) B\nFollow the capacity per Spec section 117300 2.2\n15\nThis section specifies the Basis of Design is the Handi-Care. Is the VA going to issue a sole source justification for Handi-Care or are other manufacturers acceptable?\nSpecification Section 11 73 00 - Ceiling Mounted Patient Lift, para 1.1 DESCRIPTION\nThe Lift Manufacturer identified is the VA's preferred vendor/lift. However, manufacturers who have equipment that have specifications above and beyond the specifications of the \"basis of design\" equipment are acceptable and will be considered.\n16\nThis para references VA installation checklist (Patient Safety Alert AL14-07). It appears this alert is not on the VA TIL website. Can the VA provide this document?\nSpecification Section 11 73 00 - Ceiling Mounted Patient Lift, para 3.4 INSPECTION\nSee attached\n17\nThis para references Periodic Inspection shall be provided by the manufacturer on a yearly basis in compliance with ISO 10535. Can the VA provide what the expectations are for inspection post completion/acceptance of the project?\nSpecification Section 11 73 00 - Ceiling Mounted Patient Lift, para 3.4 INSPECTION\nVA to provide annual inspections. See Project Manual Section 11 73 00 Part 1.3 Quality Assurance for project completion/acceptance requirements.\n18\nCan the VA provide the current life safety drawings for each of the buildings to include drawing that indicate both smoke and fire rated walls?\nÂ\nAvailable upon award.\n19\nCan the VA clarify where panelboards are to be installed?\nSection 26 24 16 PANELBOARDS was included in the specifications.\nSee electrical drawings for panel locations\n20\nThis para states Each room to receive new patient lifts shall be considered a Phase . The work shall be done one phase(room) at a time. Whereas the Patient Lift Locations table reflects multiple rooms under a single phase. Can the VA clarify if each room is a phase, or the rooms shown in the table the correct phasing?\nSection 010000 GENERAL REQUIREMENTS, para I. Phasing\nEach Building to be completed in entireity prior to starting an additional building. See table for the work hours and amount of rooms to be worked at 1 time.\n21\nThis para states the Contractor shall submit and receive approval for an accepted Submittal Registry. Pages 40 47 of the specification contains a Submittal Registry. Can the VA confirm that this is the Submittal Registry for the project or can software such as Procore be used?\nSection 010000 GENERAL REQUIREMENTS, para 1.11 SUBMITTAL REGISTRY\nContractor must develop a submittal registry including anticipated submittal dates. Contractor to utilize a Construction Administration software.\n22\nWhat is the VA review period that we should expect for submitted RFIs ?\nSection 010000 GENERAL REQUIREMENTS, para 1.12 REQUESTS FOR INFORMATION\n7 days for RFIs and 15 days for Submittals\n23\nCan the VA confirm that the project schedule has to be cost loaded?\nSection 013216-15 PROJECT SCHEDULES, para 1.6 WORK ACTIVITY/EVENT COST DATA\nYes, cost loading required.\n24\nCan the VA confirm that if detail 2/A502 welding is required, is the VA ok with welding above ceiling within the hospital?\nÂ\nComply with Welding permit regulations.\n25\nDetail 2/A502 reflects Unistrut attached to the top chord of the joist, whereas detail 7/a502 reflects connection at the bottom chord. Which is correct?\nÂ\nDetail 2 provides guidance on when this condition is to be implemented.\n26\nThis enlarged plan reflects section 2 for both views. Should they reference details 1 & 2/501?\nDrawing Sheet A115, ENLARGED PLAN 1B175\nYes, both Details apply.\n27\nCan the VA confirm that this is a drywall ceiling in this area and the contractor is to cut access into the ceiling, as there are no demolition notes on the sheet?\nDrawing Sheet A124, ENLARGED PLAN 725\nDrywall ceiling to be modified as necessary to mount new ceiling lift.\n28\nCan the VA confirm that this is a drywall ceiling in this area and the contractor is to cut access into the ceiling, as there are no demolition notes on the sheet?\nDrawing Sheet A124, ENLARGED PLAN 721\nDrywall ceiling to be modified as necessary to mount new ceiling lift.\n29\nThis sheet does not indicate which sections are applicable to the space, IE details on A501 that would indicate the type of structure above?\nDrawing Sheet A135, ENLARGED PLAN B1025\nRefer to Sheet A501 Detail 2.\n30\nCan the VA please provide existing finished ceiling heights for all rooms?\nÂ\nBuilding 12, Building 217(level 2) Ceiling: 10', Building 113,128,217 (level 1), Room B1-2-G226, Room B8- 1- 106R, Building 200 ( basement, level 1, level 2) Ceiling: 9', Building 200 level 7 ceiling: 10' 0'', Building 200 (room 709,716) Building 200 (level 10,11,13) ceiling: 9' 0'', Building 228 ceiling: 9' 3''\n31\nCan the VA provide the floor to deck height in each room?\nÂ\nB1-3-D355, B1-2-G201,B1-2-G226, Building 228 Level 5, Floor to Floor: 13'. Building 12 : 11'8''. Building 113, 217 (level 1) and 228 basement 13' 8''. Building 217 level 2 Floor to Roof 14'.Building 200 basement 13' 9''. Building 200 level 1 12' 5''. Building 200 level 2 11' 9''. Building 200 level 7, 10,11,13: 11' 3''.\n32\nCan the VA provide the manufacture of the existing Cubicle Curtain Tracks that are to be extended and or modified?\nÂ\nExisting tracks are Medcare.\n33\nCan the VA provide the manufacture of any new Cubicle Curtain Tracks that are required?\nÂ\nFollow Project Manual Bid Specifications Section 10 21 23 (Attachment 2).\n34\nCan the VA confirm that Cubicle Curtains are VA furnished/ VA installed?\nÂ\nVA furnishes and installs track curtains.\n35\nPlease clarify that if there are ducts, electrical or any other service in that would prohibit the installation of a given lift based on the locations shown, that each instance would be worked out as a change in condition?\nÂ\nGC to make every effort to install lifts as designed. Unforseen conditions will be addressed as they arise.\n36\nThe bid schedule has 60 lifts indicated, whoever the lft schedule reflects 58. Can the VA clarify if 60 lifts are required or 58?\nÂ\nProvide 61 Lifts. The (1) lift in Bldg 128 Room A100 can be considered to be used in one of the single track installation locations, which would then make the total 60.\n1\nPlease confirm the SSHO duties can be fulfilled by the prime contractor superintendent.\nReference: 013526 Safety Spec SSHO\nYes, this is acceptable\n2\nPlease verify that firestop needs to be installed by a firm that has been approved by FM Global? Or can firestop be installed by installers who hold a manufacturer s certification such as Hilti or 3M?\n078400 Firestop Quality Assurance\nFirestop needs to meet the requirements of the wall. Any of the three mentioned installers are acceptable.\n3\nPlease verify that firestop inspections are required as part of this contract.\n078400 Firestop Quality Assurance\nContractor to provide Quality control. VA will provide inspection.\n4\nPlease verify the designated contractor laydown area for this project. Will construction fencing be required around job trailer, storage unit, and construction dumpster?\nContractor Laydown/Storage\nAvailable upon award.\n5\nWill the owner move or relocate existing furniture/equipment in rooms prior to construction?\nOwner furniture/EquipmentÂ Â Â Â Â Â Â Â Â Â Â Â Â\nContractor to relocate existing furniture with coordination from COR.\n1\nPlease confirm that the owner is applying and paying for the building permit or should we carry an allowance for this.\nGeneral\nBuilding Permits are not required on Federal Property.\n2\nBased on ICRA documentation, level II containment cannot be used for high-risk group type B projects. Please confirm the level 2 designation on Sheet GI001 for the high-risk type B projects is correct.\nÂ\nDesignation is correct and approved by Infection Control.\n3\nPlease confirm if we need to fireproof/ fire spray the steel in the ambulance area\nÂ\nNot Required\n4\nWe understand that there are some restrictions as to the number of rooms that we can work on at any one time on a floor but please confirm whether we are restricted from working in rooms on multiple floors at the same time.\nÂ\nNo restrictions on working on multiple floors as long as the Construction schedule is followed.\n5\nShould we include time for punch lists for each room. If so, please confirm how many days.\nÂ\nAE recommends 1 punch per building to set standards. COR recommends 1 hour/lift.\n6\nPlease provide a site plan for each building for staging our dumpsters\nÂ\nVA to provide guidance on Contractor Staging Areas during Pre-Construction phase.\n7\nPlease confirm hangers for the track for the patient lift interfere with the ACT grid and lights like B1025 where the track and hangers are drawn penetrating the ACT grid. Please specify how you would like us to proceed.\n095100 Acoustical Ceilings\nAdjust ceiling track layout to avoid existing conditions\n8\nPlease confirm that the replacement of the existing ACT tile and grid is not included in our scope of work.\nÂ\nGC to confirm ACT ceiling prior to work and replace damaged ACT and Grid\n9\nPlease provide building standards for ACT tiles and grid specifications for existing material.\nÂ\nStandard Room - ARMSTRONG Ceiling Tile: 1910A, 24 in x 24 in, Square Lay-In, 15/16 in Grid Size, 0.75 NRC, 12 PK or ARMSTRONG Ceiling Tile: 1721B, 24 in x 48 in, Square Lay-In, 15/16 in Grid Size, 0.55 NRC, 8 PK\nCleanroom - ARMSTRONG Ceiling Tile: 1720B, 24 in x 24 in, Square Lay-In, 15/16 in Grid Size, 0.55 NRC, 12 PK\n10\nPlease provide building standards for paint colors of doors, frames, walls and ceilings.\n099000 Painting\nIf any doors, walls, or frames need painting, contractors need to match existing.\nFor ceilings, Hines VA prefers Benjamin Moore Flat Ceiling White.\n11\nPlease confirm whether we are to bid for a continuous charging system or a docking station for charging the lift equipment.\n110000 Equipment\nDocking Station is the bidding option\n\nRFI Attachment (Att1)\nS06 VA Alert 14-07\n\nProposal Due DATE / TIME: April 22, 2025, at 1:00 p.m. CST.\n\nALL QUESTIONS REGARDING THIS SOLICITATION SHALL BE SENT TO THE FOLLOWING INDIVIDUALS:\nDonita Grace -- Donita.Grace@va.gov\n\nThis solicitation can be monitored on the Vendor Portal.\n\nContractors shall ensure all amendments are acknowledged on Page 2 of the SF-1442.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C25225B0011","product_service_code":"Z1DA"},{"award":{"awardee":{}},"dates":{"posted":"2025-04-16","posted_at":"2025-04-16T20:07:46.130Z","created_at":"2025-04-16T20:07:44.205Z","modified_at":"2025-05-23T04:04:31.756Z","response_deadline":{"raw":"2025-04-22T13:00:00-05:00","utc":"2025-04-22T18:00:00Z","date":"2025-04-22","time":"13:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/7160a290accc40f0895cd3f0746a4ce0/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z1DA--Install Patient Lifts 578-15-001","agency":{"office":{"code":"36C252","name":"252-NETWORK CONTRACT OFFICE 12 (36C252)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"53214","city":"MILWAUKEE","state":"WI","country":"USA"},"organization_id":"100180018","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-05-22","archive_type":"auto_custom"},"history":[{"index":9,"title":"Z1DA--578-15-001 Install Patient Lifts - Construction Multiple Locations","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-05-14T20:27:35.306Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"56f81639de004abca4d1aff26fa44595","solicitation_number":"36C25225B0011","related_opportunity_id":"7160a290accc40f0895cd3f0746a4ce0"},{"index":7,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-16T20:07:46.130Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"7160a290accc40f0895cd3f0746a4ce0","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":4,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T19:15:26.849Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ef6048789f184febac3db563950904f9","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":3,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-31T19:45:11.261Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"331d14a464094031b2e75c667369fbe1","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":2,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T17:26:31.797Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"72b2ca4b2b9a4f56a870417eb298d1e7","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"},{"index":1,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T13:08:29.280Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723","solicitation_number":"36C25225B0011","related_opportunity_id":"c4beb54ad543492bbd4e1cc3bdb337e7"}],"contacts":[{"name":"Donita L Grace","role":"primary","email":"donita.grace@va.gov","title":"Contractor"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"7160a290accc40f0895cd3f0746a4ce0","lineage_id":"264d3d894bfa4a34a47b9cba1b3ba723","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-17T11:03:00.086617275Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"2554ab9266da1d765734aeb2627300dc1d6d43b038015ce2c0825adaa4373931","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-17T11:03:00.086617275Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"SOLICITATION 36C25225B0011\nAMENDMENT A0004\nApril 16, 2025 \n\nProject: Install Patient Lifts\nProject Number: \n578-15-001\nLocation: Edward Hines Jr. VA Hospital\n\nAmendment 0004 hereby incorporates the following clarifications/change(s) into the solicitation package.\n\nRemove the following provisions:\n\n  52.222-9, Apprentices and Trainees\n  52.222-21, Prohibition of Segregated Facilities\n  52.222-22, Previous Contracts and Compliance Reports\n  52.222-25, Affirmative Action Compliance   52.222-26, Equal Opportunity\n  52.222-27, Affirmative Action Compliance Requirements for Construction\n \nAdd Clause 852.222-71\nInsert G - 852.222.71 Compliance with Executive Order 13899. (DEVIATION) (APR 2025)\n\n\nNotices:\n\nNote 1: Â Contractors are still covered by existing United States laws on civil rights/ nondiscrimination. These laws apply whether or not the company is a government contractor.Â  In addition, FAR subparts 22.13, Equal Opportunity for Veterans, and 22.14, Employment of Workers with Disabilities, and their related provisions and clauses, are based on statute and are therefore not covered by E.O. 11246 or affected by this deviation.\n\nNote 2:  System updates may lag policy updates. The System for Award Management (SAM) may continue to require entities to complete representations based on provisions that are not included in agency solicitations. Examples include 52.222-25, Affirmative Action Compliance, and paragraph (d) of 52.212-3, Offeror Representations and Certifications Commercial Products and Commercial Services. Contracting officers will not consider these representations when making award decisions or enforce requirements. Entities are not required to, nor are they able to, update their entity registration to remove these representations in SAM. \n\nProposal Due DATE / TIME: April 22, 2025, at 1:00 p.m. CST.   \n \nALL QUESTIONS REGARDING THIS SOLICITATION SHALL BE SENT TO THE FOLLOWING INDIVIDUALS:\nDonita Grace -- Donita.Grace@va.gov\n\nThis solicitation can be monitored on the Vendor Portal.\n\nContractors shall ensure all amendments are acknowledged on Page 2 of the SF-1442.","text":"SOLICITATION 36C25225B0011\nAMENDMENT A0004\nApril 16, 2025\n\nProject: Install Patient Lifts\nProject Number:\n578-15-001\nLocation: Edward Hines Jr. VA Hospital\n\nAmendment 0004 hereby incorporates the following clarifications/change(s) into the solicitation package.\n\nRemove the following provisions:\n\n52.222-9, Apprentices and Trainees\n52.222-21, Prohibition of Segregated Facilities\n52.222-22, Previous Contracts and Compliance Reports\n52.222-25, Affirmative Action Compliance 52.222-26, Equal Opportunity\n52.222-27, Affirmative Action Compliance Requirements for Construction\n\nAdd Clause 852.222-71\nInsert G - 852.222.71 Compliance with Executive Order 13899. (DEVIATION) (APR 2025)\n\nNotices:\n\nNote 1: Â Contractors are still covered by existing United States laws on civil rights/ nondiscrimination. These laws apply whether or not the company is a government contractor.Â In addition, FAR subparts 22.13, Equal Opportunity for Veterans, and 22.14, Employment of Workers with Disabilities, and their related provisions and clauses, are based on statute and are therefore not covered by E.O. 11246 or affected by this deviation.\n\nNote 2: System updates may lag policy updates. The System for Award Management (SAM) may continue to require entities to complete representations based on provisions that are not included in agency solicitations. Examples include 52.222-25, Affirmative Action Compliance, and paragraph (d) of 52.212-3, Offeror Representations and Certifications Commercial Products and Commercial Services. Contracting officers will not consider these representations when making award decisions or enforce requirements. Entities are not required to, nor are they able to, update their entity registration to remove these representations in SAM.\n\nProposal Due DATE / TIME: April 22, 2025, at 1:00 p.m. CST.\n\nALL QUESTIONS REGARDING THIS SOLICITATION SHALL BE SENT TO THE FOLLOWING INDIVIDUALS:\nDonita Grace -- Donita.Grace@va.gov\n\nThis solicitation can be monitored on the Vendor Portal.\n\nContractors shall ensure all amendments are acknowledged on Page 2 of the SF-1442.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C25225B0011","product_service_code":"Z1DA"},{"award":{"date":"2025-05-14","amount":"1137659.00","number":"36C25225C0035","awardee":{"raw":"TL Services, Inc. RIVERVIEW 33578 FLK","uei":"PKY8AMMMHL38","cage":"1M8V9","name":"TL Services, Inc.","location":{"zip":"33578","city":{"name":"RIVERVIEW"},"state":{"name":"FL"},"country":{"code":"FLK","name":"FALKLAND ISLANDS (ISLAS MALVINAS)"}}}},"dates":{"posted":"2025-05-14","posted_at":"2025-05-14T20:27:35.306Z","award_date":"2025-05-14","created_at":"2025-05-14T20:27:33.084Z","modified_at":"2025-06-14T03:55:46.500Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/56f81639de004abca4d1aff26fa44595/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z1DA--578-15-001 Install Patient Lifts - Construction Multiple Locations","agency":{"office":{"code":"36C252","name":"252-NETWORK CONTRACT OFFICE 12 (36C252)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"53214","city":"MILWAUKEE","state":"WI","country":"USA"},"organization_id":"100180018","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-06-13","archive_type":"auto_custom"},"history":[{"index":5,"title":"Z1DA--578-15-001 Install Patient Lifts - Construction Multiple Locations","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-05-14T20:27:35.306Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"56f81639de004abca4d1aff26fa44595","solicitation_number":"36C25225B0011","related_opportunity_id":"7160a290accc40f0895cd3f0746a4ce0"},{"index":3,"title":"Z1DA--Install Patient Lifts 578-15-001","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-16T20:07:46.130Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"7160a290accc40f0895cd3f0746a4ce0","solicitation_number":"36C25225B0011","parent_opportunity_id":"264d3d894bfa4a34a47b9cba1b3ba723"}],"contacts":[{"name":"Donita Grace","role":"primary","email":"donita.grace@va.gov","phone":"(414) 844-4860","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"56f81639de004abca4d1aff26fa44595","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"264d3d894bfa4a34a47b9cba1b3ba723","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-15T03:16:11.671082390Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"0d3e65c2b5e0288d1cb7712ddc3157e944969b4d5f01de12146f7e27c6ec4dd2","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-15T03:16:11.671082390Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"AWARD NOTICE","text":"AWARD NOTICE","origin":"detail"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"36C25225B0011","product_service_code":"Z1DA"}],"due_at":"2025-04-22T18:00:00Z","due_date":"2025-04-22","closes_at":"2025-04-22T18:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","state":"IL","county":"17031","county_name":"Cook County","city":null,"city_name":null,"country":"USA","state_source":"sam_zip","state_evidence":null,"site_key":null,"winner_key":"PKY8AMMMHL38","amount":"1137659.00","linked_awards":7,"cancelled":false,"archived":true,"updated_at":"2026-11-15T04:08:10.553974Z","principal_notice_id":"56f81639de004abca4d1aff26fa44595","description":{"text":"AWARD NOTICE","html":"AWARD NOTICE","origin":"detail"},"contacts":[{"name":"Donita Grace","role":"primary","email":"donita.grace@va.gov","phone":"(414) 844-4860","title":"Contract Specialist"}],"place_of_performance":null,"office_address":{"zip":"53214","city":"MILWAUKEE","state":"WI","country":"USA"},"naics_codes":["236220"],"award":{"date":"2025-05-14","amount":"1137659.00","number":"36C25225C0035","awardee":{"raw":"TL Services, Inc. RIVERVIEW 33578 FLK","uei":"PKY8AMMMHL38","cage":"1M8V9","name":"TL Services, Inc.","location":{"zip":"33578","city":{"name":"RIVERVIEW"},"state":{"name":"FL"},"country":{"code":"FLK","name":"FALKLAND ISLANDS (ISLAS MALVINAS)"}}}},"attachments":[{"resource_id":"3af4b503b3a14c16a2f1bfee2f5053ed","name":"36C25225B0011.docx","kind":"file","mime_type":".docx","size_bytes":24727,"posted_at":"2025-02-05T16:47:31.065Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/3af4b503b3a14c16a2f1bfee2f5053ed/download","mirrored":false},{"resource_id":"36f6f655ddf24a779b7fb05b2358e71d","name":"36C25225B0011_1.docx","kind":"file","mime_type":".docx","size_bytes":105297,"posted_at":"2025-02-20T13:08:29.280Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/36f6f655ddf24a779b7fb05b2358e71d/download","mirrored":false},{"resource_id":"a201238a96fe4e9ea0926fd5967d9887","name":"36C25225C0035_2.docx","kind":"file","mime_type":".docx","size_bytes":22832,"posted_at":"2025-05-14T20:27:35.306Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/a201238a96fe4e9ea0926fd5967d9887/download","mirrored":false},{"resource_id":"39943e867f6343a3aeffa53cff947a1c","name":"S02 - Att1 - Bid Drawings 250124.pdf","kind":"file","mime_type":".pdf","size_bytes":35413921,"posted_at":"2025-02-20T13:08:29.280Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/39943e867f6343a3aeffa53cff947a1c/download","mirrored":false},{"resource_id":"5f4500b5cd1d41be85a6fcf906569b52","name":"S02 - Att2 - Project Manual Bid Specs 250124.pdf","kind":"file","mime_type":".pdf","size_bytes":3714219,"posted_at":"2025-02-20T13:08:29.280Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/5f4500b5cd1d41be85a6fcf906569b52/download","mirrored":false},{"resource_id":"dc39814fb7cb4882a9f0d8b84354fa05","name":"S02 - Att3 - Contractor Parking.pdf","kind":"file","mime_type":".pdf","size_bytes":490701,"posted_at":"2025-02-20T13:08:29.280Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/dc39814fb7cb4882a9f0d8b84354fa05/download","mirrored":false},{"resource_id":"9dc11192132f4cfebaa009f09bbdea1e","name":"S02 - Att4 - Contractor Badging - Fingerprint Request Form 2025.pdf","kind":"file","mime_type":".pdf","size_bytes":568118,"posted_at":"2025-02-20T13:08:29.280Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/9dc11192132f4cfebaa009f09bbdea1e/download","mirrored":false},{"resource_id":"00907be86973479891e73684dd473001","name":"S02 - Att5 - Pre-Construction Checklist.pdf","kind":"file","mime_type":".pdf","size_bytes":211661,"posted_at":"2025-02-20T13:08:29.280Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/00907be86973479891e73684dd473001/download","mirrored":false},{"resource_id":"ca9512cd2f184609a9bb84c2ddbfc9e5","name":"S02 - Att6 - Safety and Health During Construction Activities.pdf","kind":"file","mime_type":".pdf","size_bytes":4674307,"posted_at":"2025-02-20T13:08:29.280Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/ca9512cd2f184609a9bb84c2ddbfc9e5/download","mirrored":false},{"resource_id":"a74e791f4eff458c84a2b0ec758df33a","name":"S02 - Att7 - Cutting Welding and Other Hot Work.pdf","kind":"file","mime_type":".pdf","size_bytes":39703,"posted_at":"2025-02-20T13:08:29.280Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/a74e791f4eff458c84a2b0ec758df33a/download","mirrored":false},{"resource_id":"9b10c7ac471a4f24b61dfa74985e9aa7","name":"S02 - Att8 - Above Ceiling Entry and Wall Construction Permits.pdf","kind":"file","mime_type":".pdf","size_bytes":382880,"posted_at":"2025-02-20T13:08:29.280Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/9b10c7ac471a4f24b61dfa74985e9aa7/download","mirrored":false},{"resource_id":"1a46e7b214fd4f67b99fd081304ae4af","name":"S02 - Att 9a - Pre-Construction Risk Assessment PCRA.pdf","kind":"file","mime_type":".pdf","size_bytes":1585204,"posted_at":"2025-02-20T13:08:29.280Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/1a46e7b214fd4f67b99fd081304ae4af/download","mirrored":false},{"resource_id":"965f6a3e007544dabc0afb837bc09ced","name":"S02 - Att 9b - PCRA Compiled Locations List.pdf","kind":"file","mime_type":".pdf","size_bytes":107714,"posted_at":"2025-02-20T13:08:29.280Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/965f6a3e007544dabc0afb837bc09ced/download","mirrored":false},{"resource_id":"c58765d7c7574b44a8fd84461e8fbaf7","name":"S02 - Att10a - Infection Control Risk Assessment ICRA - Level 1.pdf","kind":"file","mime_type":".pdf","size_bytes":2329925,"posted_at":"2025-02-20T13:08:29.280Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/c58765d7c7574b44a8fd84461e8fbaf7/download","mirrored":false},{"resource_id":"c1a6470a32a041b79326bf6ec8d3ac7c","name":"S02 - Att10b - Infection Control Risk Assessment ICRA - Level 2.pdf","kind":"file","mime_type":".pdf","size_bytes":2328123,"posted_at":"2025-02-20T13:08:29.280Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/c1a6470a32a041b79326bf6ec8d3ac7c/download","mirrored":false},{"resource_id":"4738bfc9ecc94a09b0f02729d8c1b2ff","name":"S02 - Att10c - ICRA Compiled Locations List.pdf","kind":"file","mime_type":".pdf","size_bytes":107141,"posted_at":"2025-02-20T13:08:29.280Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/4738bfc9ecc94a09b0f02729d8c1b2ff/download","mirrored":false},{"resource_id":"ea0a8ab6ddc947e19b215049488b10e6","name":"S02 - Att11 - Interim Life Safety Measures ILSM.pdf","kind":"file","mime_type":".pdf","size_bytes":369449,"posted_at":"2025-02-20T13:08:29.280Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/ea0a8ab6ddc947e19b215049488b10e6/download","mirrored":false},{"resource_id":"7e4d69f2d0404395a9c034ea8adabce6","name":"S02 - Att12 - Infection Control Barrier Sample.pdf","kind":"file","mime_type":".pdf","size_bytes":2483313,"posted_at":"2025-02-20T13:08:29.280Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/7e4d69f2d0404395a9c034ea8adabce6/download","mirrored":false},{"resource_id":"e69b9b14c682400eb636d04ed8293e90","name":"S02 - Att13 - No Smoking Policy 10-1-19.pdf","kind":"file","mime_type":".pdf","size_bytes":34823,"posted_at":"2025-02-20T13:08:29.280Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/e69b9b14c682400eb636d04ed8293e90/download","mirrored":false},{"resource_id":"b3424fa84d9643ad8e34cb79dc4c193b","name":"S02 - Att14 Wage Determination IL 20240009 dtd 1.10.2025.pdf","kind":"file","mime_type":".pdf","size_bytes":80423,"posted_at":"2025-02-20T13:08:29.280Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/b3424fa84d9643ad8e34cb79dc4c193b/download","mirrored":false},{"resource_id":"8059c3b0af1d441db32ae850bba35238","name":"S02 - Att 15 Final SOW Install Patient Lifts Construction 578-15-001.pdf","kind":"file","mime_type":".pdf","size_bytes":189482,"posted_at":"2025-02-20T13:08:29.280Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/8059c3b0af1d441db32ae850bba35238/download","mirrored":false},{"resource_id":"9e606843d7ba4917bae030020007d475","name":"36C25225B0011 0001.docx","kind":"file","mime_type":".docx","size_bytes":28414,"posted_at":"2025-02-20T17:26:31.797Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/9e606843d7ba4917bae030020007d475/download","mirrored":false},{"resource_id":"3248f16e4cf3491d89ca830251fd23ba","name":"36C25225B0011 0002.docx","kind":"file","mime_type":".docx","size_bytes":16646,"posted_at":"2025-03-31T19:45:11.261Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/3248f16e4cf3491d89ca830251fd23ba/download","mirrored":false},{"resource_id":"39c39d3cb62d450eba7e9ae8ae95973c","name":"36C25225B0011 0003.docx","kind":"file","mime_type":".docx","size_bytes":120018,"posted_at":"2025-04-09T19:15:26.849Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/39c39d3cb62d450eba7e9ae8ae95973c/download","mirrored":false},{"resource_id":"859a3cc847684329945c7966b918836f","name":"S06 - Att.1 VA Alert 14-07.pdf","kind":"file","mime_type":".pdf","size_bytes":256448,"posted_at":"2025-04-09T19:15:26.849Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/859a3cc847684329945c7966b918836f/download","mirrored":false},{"resource_id":"422599ba456747049dae65e3d54e308a","name":"36C25225B0011 0004.docx","kind":"file","mime_type":".docx","size_bytes":29747,"posted_at":"2025-04-16T20:07:46.130Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/422599ba456747049dae65e3d54e308a/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C25225C0035_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C25225C0035_3600_-NONE-_-NONE-/","piid":"36C25225C0035","parent_piid":null,"award_type":"DEFINITIVE CONTRACT","vendor_key":"PKY8AMMMHL38","recipient_name":"TL SERVICES, INC.","recipient_uei":"PKY8AMMMHL38","recipient_cage":"1M8V9","recipient_city":"RIVERVIEW","recipient_state":"FL","sub_name":"Department of Veterans Affairs","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","office_key":"o-36C252","first_action_date":"2025-05-14","last_action_date":"2026-10-06","actions":4,"obligated":"1298181.71","current_total_value":"1298181.71","potential_total_value":"1298181.71","naics":"236220","psc":"Z1DA","extent_competed":"FULL AND OPEN COMPETITION AFTER EXCLUSION OF SOURCES","set_aside":"SERVICE DISABLED VETERAN OWNED SMALL BUSINESS SET-ASIDE","offers_received":7,"description":"PROJECT 578-15-001 INSTALL PATIENT LIFTS IN MULTIPLE LOCATIONS AT EDWARD HINES VA MEDICAL CENTER, HINES, IL","method":"piid","confidence":"high","evidence":["award number 36C25225C0035 equals the contract number","same awarding office 36C252"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C25227Q0069","latest_notice_id":"eed58f84a7f44ac98ced93c2b5e9ec8d","title":"S222--Grease Trap Service-FY27 Base-Tomah VAMC - December 2026 - November 2027","solicitation_number":"36C25227Q0069","notice_type":"o","first_type":"p","first_posted":"2026-11-04","last_posted":"2026-11-19","notices":3,"due_at":"2026-11-27T16:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"562998","psc":"S222","set_aside":"SBA","state":"WI","county":"55081","county_name":"Monroe County","city":"5580075","city_name":"Tomah","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Tomah VA Medical Center","site_key":"tomah-va-medical-center-wi","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C25227Q0033","latest_notice_id":"4d3caf6262ae49649e71c4eadbda1187","title":"Q702--Great Lakes Region Durable Medical Equipment (DME) Delivery Services","solicitation_number":"36C25227Q0033","notice_type":"o","first_type":"o","first_posted":"2026-11-06","last_posted":"2026-11-19","notices":3,"due_at":"2026-11-30T12:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T12:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"621610","psc":"Q702","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C25227B00020001","latest_notice_id":"7eafb50009534028818a8ee9836b9e30","title":"Z1DA--550-20-121 Demo Old Boiler Plant B100 (CON)","solicitation_number":"36C25227B0002-0001","notice_type":"o","first_type":"o","first_posted":"2026-10-21","last_posted":"2026-11-10","notices":2,"due_at":"2026-12-02T19:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"IL","county":"17183","county_name":"Vermilion County","city":"1718563","city_name":"Danville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"36C25227Q0059","latest_notice_id":"356844aa4dfe401da0c9186aa3e03e85","title":"4130--Chiller Compressor Replacement at the Edward Hines Jr. VA Hospital (Hines) Building 228","solicitation_number":"36C25227Q0059","notice_type":"o","first_type":"r","first_posted":"2026-10-16","last_posted":"2026-11-16","notices":2,"due_at":"2026-12-03T16:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"238220","psc":"J043","set_aside":"SDVOSBC","state":"IL","county":"17031","county_name":"Cook County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C25227B0006","latest_notice_id":"e4fa6ced73cf448f9259359ef2b8eeab","title":"Z1DA--537-26-101 Construction of Ogden Elevator Cab Interiors Jesse Brown VA Medical Center","solicitation_number":"36C25227B0006","notice_type":"p","first_type":"p","first_posted":"2026-10-20","last_posted":"2026-10-20","notices":1,"due_at":"2026-12-04T16:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"238290","psc":"Z1DA","set_aside":"SDVOSBC","state":"IL","county":"17031","county_name":"Cook County","city":"1714000","city_name":"Chicago","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":"Jesse Brown VA Medical Center","site_key":"jesse-brown-va-medical-center-il","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-21T04:57:30.751375Z"}],"similar_open":[{"key":"1232SA27Q0003","latest_notice_id":"0a269bf301594cce8ea15530526bce89","title":"Repair Building Systems (Peoria, IL)","solicitation_number":"1232SA27Q0003","notice_type":"k","first_type":"k","first_posted":"2026-10-27","last_posted":"2026-11-03","notices":2,"due_at":"2026-12-02T18:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12H2","sub_name":"AGRICULTURAL RESEARCH SERVICE","office_key":"o-1232SA","office_name":"USDA ARS AFM APD","naics":"236220","psc":"Z1JZ","set_aside":"SBA","state":"IL","county":"17143","county_name":"Peoria County","city":"1759000","city_name":"Peoria","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-04T05:14:00.353426Z"},{"key":"36C25227B00020001","latest_notice_id":"7eafb50009534028818a8ee9836b9e30","title":"Z1DA--550-20-121 Demo Old Boiler Plant B100 (CON)","solicitation_number":"36C25227B0002-0001","notice_type":"o","first_type":"o","first_posted":"2026-10-21","last_posted":"2026-11-10","notices":2,"due_at":"2026-12-02T19:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C252","office_name":"252-NETWORK CONTRACT OFFICE 12 (36C252)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"IL","county":"17183","county_name":"Vermilion County","city":"1718563","city_name":"Danville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"385515GMK","latest_notice_id":"65747435c0224a859780416b36f2d6bf","title":"Wilson Hall Floor 16 Electric and Elevator Machine Rooms Fire Rating and Mechanical Upgrade","solicitation_number":"385515GMK","notice_type":"o","first_type":"o","first_posted":"2026-10-22","last_posted":"2026-11-11","notices":3,"due_at":"2026-12-09T21:00:00Z","due_date":"2026-12-09","closes_at":"2026-12-09T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899034","office_name":"FERMILAB - DOE CONTRACTOR","naics":"236220","psc":"Z2AZ","set_aside":"SBA","state":"IL","county":"17089","county_name":"Kane County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-12T04:43:37.498412Z"}],"similar_open_total":192,"indexable":false}