{"canonical":"https://sealedbidder.com/opportunities/36c25026q0950","key":"36C25026Q0950","url":"https://sealedbidder.com/opportunities/36c25026q0950","title":"6540-- 541-26-3-2611-0455 - PowerRef 3 System Hardware/Software","solicitation_number":"36C25026Q0950","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-09-08T11:00:00Z","first_posted":"2026-08-27","last_posted":"2026-08-27","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"339112","psc":"6540","set_aside":"SBA","place_state":"OH","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"39035","place_county_name":"Cuyahoga County","place_city":"3916000","place_city_name":"Cleveland","winner":null,"award_amount":null,"publications":[{"notice_id":"d3f1cb94013b4a338053516e9c32d7cf","title":"6540-- 541-26-3-2611-0455 - PowerRef 3 System Hardware/Software","solicitation_number":"36C25026Q0950","notice_type":"r","base_type":"r","posted":"2026-08-27","posted_at":"2026-08-27T15:32:54.167Z","due_at":"2026-09-08T11:00:00Z","due_date":"2026-09-08","cancelled":false,"archived":true,"archive_date":"2026-11-07","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/d3f1cb94013b4a338053516e9c32d7cf/view","enriched":true,"history":[{"index":1,"title":"6540-- 541-26-3-2611-0455 - PowerRef 3 System Hardware/Software","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-27T15:32:54.167Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"d3f1cb94013b4a338053516e9c32d7cf","solicitation_number":"36C25026Q0950"}]}],"latest_notice_id":"d3f1cb94013b4a338053516e9c32d7cf","first_type":"r","notices":[{"dates":{"posted":"2026-08-27","posted_at":"2026-08-27T15:32:54.167Z","created_at":"2026-08-27T15:32:51.910Z","modified_at":"2026-08-27T15:32:54.167Z","response_deadline":{"raw":"2026-09-08T07:00:00-04:00","utc":"2026-09-08T11:00:00Z","date":"2026-09-08","time":"07:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/d3f1cb94013b4a338053516e9c32d7cf/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"6540-- 541-26-3-2611-0455 - PowerRef 3 System Hardware/Software","agency":{"office":{"code":"36C250","name":"250-NETWORK CONTRACT OFFICE 10 (36C250)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"publication":"published","archive_date":"2026-11-07","archive_type":"auto_custom"},"history":[{"index":1,"title":"6540-- 541-26-3-2611-0455 - PowerRef 3 System Hardware/Software","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-27T15:32:54.167Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"d3f1cb94013b4a338053516e9c32d7cf","solicitation_number":"36C25026Q0950"}],"contacts":[{"fax":"NA","name":"KEVIN PEEPLES","role":"primary","email":"Kevin.peeples@va.gov","phone":"216-416-1600","title":"CONTRACT SPECIALIST"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"d3f1cb94013b4a338053516e9c32d7cf","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"d3f1cb94013b4a338053516e9c32d7cf","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-17T06:02:30.103293762Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"55a72282150057504d291dc38809bc6ca8e3c981bcdd720ffcae07244ff9695b","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-06T04:42:59.950874882Z","first_seen_at":"2026-09-15T22:52:52.472456Z"},"description":{"html":"SOURCES SOUGHT NOTICE\n\nTHIS REQUEST FOR INFORMATION (RFI/Sources Sought) IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 10.002(b)(2), FAR 12.101, FAR 12.103 & FAR 12.202(a).\nDISCLAIMER\nThis request for information, sources sought (RFI/Sources Sought) is issued solely for information and planning purposes only and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  IAW FAR 10.002(b)(2), FAR 12.101, FAR 12.103 & FAR 12.202(a), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\nThis is NOT a solicitation announcement.  This is a sources sought/RFI only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified Small Businesses under NAICS 339112, (Surgical and Medical Instrument Manufacturing industry), but does not exclude others from responding. Responses to this source sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this source sought, a solicitation announcement may be published.  Responses to this source sought synopsis are not considered adequate responses for a solicitation announcement.  \n\nSOURCES SOUGHT DESCRIPTION\nThe Department of Veterans Affairs, Network Contracting Office 10, Louis Stokes Cleveland VA Medical Center, is seeking sources that can provide a  Accommodation Meter plusoptiX R09 (PowerRef 3) and accessories  for Surgical Department Mechanical Room that meets the following: \n\nProduct/Items\nITEM NO.             DESCRIPTION                                   QUANTIYT UNIT\nOR STOCK NO.                                                        \n             \n             Request purchase only of Accommodation Meter plusoptiX R09 (PowerRef 3)\n\nAccommodation Meter plusoptiX R09 (PowerRef 3) incl. Medical Power Adaptor      1    EA\n   2. Software Licence RP Dynamic measurements of accommodation in sphere, convergence and pupil size changes in scotopic, mesopic and photopic conditions                                                                            1    EA\n   3. Complete measurement set-up kit (includes former MIRROR, SLIDE and REST)                                         1     EA\n   4. Shipping and Handling                         1     EA\n     \n\nSpecifications & Salient Characteristics\n\nTechnical Specifications\nRefraction (vertical meridian): \nBinocular and monocular measurement\nSpherical range: +5.00 D to  7.00 D, in increments of 0.01 D\nPupil size: \nRange: 4.0 8.0 mm, measured in 0.1 mm steps, Â±10% accuracy \nPupil distance (interpupillary distance): \nMeasured in 1.0 mm steps, Â±10% accuracy \nSampling rate: \n50 Hz (one measurement every 20 ms) \nMeasuring distance: \nStandard working distance of 1 m (Â± 5 cm) \nMeasurement principle: \nBinocular, dynamic photoretinoscopy\n\nInterfaces & Power Requirements\nInterfaces: \n4 Ã— USB ports\n1 Ã— VGA output (supports 1024 Ã— 768 resolution) \nPower supply: \nAC 100 240 V, 50 60 Hz, 2.5 A (excluding monitor) \n\nEnvironmental Conditions\nOperating temperature: 10 35 Â°C (50 92 Â°F)\nStorage temperature: 0 50 Â°C (32 122 Â°F)\nRelative humidity (non-condensing): \nOperating: 20 80%\nStorage: 10 85%\n\nData Output & Logging\nMeasurements are continuously recorded into a CSV  logfile,  capturing:\nTimestamp (every 20 ms)\nLED brightness (percentage)\nPupil detection status (found/not found)\nPupil size (width & height in mm)\nPupil brightness (digital units 0 255)\nPurkinje reflex size & position (pixels: X & Y)\nGaze angles (horizontal & vertical in degrees)\nSpherical refraction per eye, including mean & standard deviation over last 10 frames\nInterpupillary distance in mm\nCamera horizontal angle \n\nSalient Functional Characteristics\nBinocular dynamic measurement: \nTracks continuous changes in accommodation (sphere), convergence, and pupil size for both eyes \n50 Hz real-time sampling: \nHigh temporal resolution enables precise tracking of fast dynamics \nOpen-field fixation: \nUses a hot mirror to allow naturalistic visual targets at any distance \nNon-contact operation: \nMeasurements gathered without touching the subject \nResearch-grade device: \nDesigned specifically for scientific applications investigating accommodation response times, IOL performance, convergence accommodation relationships, and neuro-ophthalmologic metrics \n\nIntegration & Output\nData can be streamed via USB or recorded to a VGA-connected monitor\nOutputs are ideal for integration into custom research setups and signal logging systems\nSalient Characteristics   Plusoptix PowerRef 3 Accommodation Measurement System\nThe PowerRef 3 system must meet the following minimum salient characteristics to satisfy clinical research and operational requirements for binocular, real time accommodation and convergence measurement:\n1. Measurement Capability\nMust perform simultaneous binocular measurement of:\n  Refractive state (sphere, vertical meridian)\n  Convergence/vergence\n  Pupil size (both eyes)\nMust provide continuous, real time data acquisition suitable for dynamic accommodative and vergence analysis.\n2. Sampling and Data Output\nMust provide a minimum sampling rate of 50 Hz (20 ms intervals) to capture rapid accommodation fluctuations.\nMust support continuous data streaming and export to external computers and research software.\nMust allow real time or recorded output in spreadsheet compatible formats.\n3. Optical and System Design\nMust use infrared photorefraction technology.\nMust include an open field optical design, enabling natural fixation on targets at varying distances without the constraints of an enclosed optical path.\nMust incorporate a hot mirror target presentation system permitting both stationary and moving fixation stimuli at adjustable distances.\n4. Calibration and Reliability\nMust be engineered for long term calibration stability, requiring no routine recalibration under normal use.\nMust include durable optics and electronics suited for repeated daily research use.\n5. Fixation Target Flexibility\nMust support user selectable fixation targets, including moving or adjustable distance stimuli for controlled accommodation and vergence testing.\n6. Integration and Compatibility\nMust be compatible with standard Windows based data acquisition systems, research platforms, or laboratory PCs.\nMust allow USB or networked connection for external data handling.\n7. System Configuration\nMust include all necessary hardware, software, cables, and accessories required for full operational use upon installation.\n\nBackground: The VA-ORD-funded study  Home-based Treatment of Binocular Eye Dysfunction in Veterans with Traumatic Brain Injury  (Mark Walker, M.D., principal investigator) will investigate physiological mechanisms underlying near vision impairment in Veterans and will conduct a pilot study to explore the feasibility and potential efficacy of virtual-reality for customized home therapy of convergence insufficiency. This study requires robust measures of ocular accommodation, the change in the shape of the eye s lens to focus on near images. For that purpose, we require a device that can measure directly changes in lens curvature and that can do this dynamically at a high enough sample rate to measure not only the amount but also the rate of accommodation. The device must also have integrated eye tracking for simultaneous measurement of ocular vergence. The PlusOptix PowerRef3 is the only currently available device that measures accommodation directly and dynamically, is portable, and includes eye tracking to measure simultaneous convergence.\nScope: AcquisitionÂ of an automatedÂ retinoscopy-based accommodation and ocular vergence measurement device, itsÂ controlÂ software, andÂ associatedÂ measurement apparatus.Â Â Â \nThe information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications. \nIf you are interested and can provide the sought-out supplies/services, please provide the requested information indicated below. Response to this notice should include company name, address, point of contact, DUNS number, and size of business pursuant to the following questions:  \nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)\n\nIs your company considered small under the NAICS code identified under this RFI? If not, is your company considered small under a related NAICS code?\n\nAre you the manufacturer or distributor of the items being referenced above (or equivalent product/solution)? What is the manufacturing country of origin of these items?\n\nIf you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).\n\nIf you re a small business and you are an authorized distributor/reseller for the items identified above (or an equivalent solution), do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\n\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number.\n\nIf you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions you are providing information for available on your schedule/contract?\n\nPlease provide general pricing of your products/solution for market research purposes.\n\nPlease submit your capabilities in regard to the salient characteristics being provided and any information pertaining to  brand name or equal to  items to establish capabilities for planning purposes.  \nNo re-manufactures or gray market items will be acceptable. Vendor shall be an Original Equipment Manufacturer (OEM), authorized dealer, authorized distributor or authorized reseller verified by an authorization letter or other documents from the OEM.\nSUBMISSION\nResponses to this notice shall be submitted via email to kevin.peeples@va.gov and robert.blasko@va.gov referencing 36C25026Q0950 in the email. Telephone responses will not be accepted.  Responses must be received no later than September 8, 2026, at 7:00am EST, (Eastern Standard Time). If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this request for information.  Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation.\nCLAUSES\n\n\n\n\n\n\nFAR Number\nTitle\nDate\n52.209-6\nPROTECTING THE GOVERNMENT S INTEREST WHEN SUBCONTRACTING WITH CONTRACTORS DEBARRED, SUSPENDED, OR PROPOSED FOR DEBARMENT\nJAN 2025\n52.212-4\nCONTRACT TERMS AND CONDITIONS-- COMMERCIAL ITEMS\nNOV 2023\n\n\n\n52.222-90\n\n52.232-33\nADDRESSING DEI DISCRIMINATION BY FEDERAL\nCONTRACTORS\nPAYMENT BY ELECTRONIC FUNDS TRANSFER   SYSTEM FOR AWARD MANAGEMENT \nAPR 2026\n\nOCT 2018\n52.252-2\nCLAUSES INCORPORATED BY REFERENCE\nFEB 1998\n52.232-40\nPROVIDING ACCELERATED PAYMENTS TO SMALL BUSINESS SUBCONTRACTORS\nMAR 2023\n52.233-1\nDISPUTES\nMAY 2014\n52.233-3\nPROTEST AFTER AWARD\nAUG 1996\n852.219-76\n\n\n852.203-70\nVA NOTICE OF LIMITATIONS ON SUBCONTRACTING-CERTIFICATE OF COMPLIANCE FOR SUPPLIES AND PRODUCTS (DEVIATION)\n\nCOMMERCIAL ADVERTISING\nJAN 2023\n\n\nMAY 2018\n852.232-72\nELECTRONIC SUBMISSION OF PAYMENT REQUESTS\nNOV 2018\n852.237-70\nCONTRACTOR RESPONSIBILITIES\nOCT 2019\n\n\n\n\nPROVISIONS\n\n\n\n\n\n\n\n52.212-1\nINSTRUCTIONS TO OFFERORS-COMMERCIAL ITEMS\nSEP 2023\n52.212-2\nEVALUATION--COMMERCIAL ITEMS\nNOV 2021","text":"SOURCES SOUGHT NOTICE\n\nTHIS REQUEST FOR INFORMATION (RFI/Sources Sought) IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 10.002(b)(2), FAR 12.101, FAR 12.103 & FAR 12.202(a).\nDISCLAIMER\nThis request for information, sources sought (RFI/Sources Sought) is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 10.002(b)(2), FAR 12.101, FAR 12.103 & FAR 12.202(a), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nThis is NOT a solicitation announcement. This is a sources sought/RFI only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified Small Businesses under NAICS 339112, (Surgical and Medical Instrument Manufacturing industry), but does not exclude others from responding. Responses to this source sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this source sought, a solicitation announcement may be published. Responses to this source sought synopsis are not considered adequate responses for a solicitation announcement.\n\nSOURCES SOUGHT DESCRIPTION\nThe Department of Veterans Affairs, Network Contracting Office 10, Louis Stokes Cleveland VA Medical Center, is seeking sources that can provide a Accommodation Meter plusoptiX R09 (PowerRef 3) and accessories for Surgical Department Mechanical Room that meets the following:\n\nProduct/Items\nITEM NO. DESCRIPTION QUANTIYT UNIT\nOR STOCK NO.\n\nRequest purchase only of Accommodation Meter plusoptiX R09 (PowerRef 3)\n\nAccommodation Meter plusoptiX R09 (PowerRef 3) incl. Medical Power Adaptor 1 EA\n2. Software Licence RP Dynamic measurements of accommodation in sphere, convergence and pupil size changes in scotopic, mesopic and photopic conditions 1 EA\n3. Complete measurement set-up kit (includes former MIRROR, SLIDE and REST) 1 EA\n4. Shipping and Handling 1 EA\n\nSpecifications & Salient Characteristics\n\nTechnical Specifications\nRefraction (vertical meridian):\nBinocular and monocular measurement\nSpherical range: +5.00 D to 7.00 D, in increments of 0.01 D\nPupil size:\nRange: 4.0 8.0 mm, measured in 0.1 mm steps, Â±10% accuracy\nPupil distance (interpupillary distance):\nMeasured in 1.0 mm steps, Â±10% accuracy\nSampling rate:\n50 Hz (one measurement every 20 ms)\nMeasuring distance:\nStandard working distance of 1 m (Â± 5 cm)\nMeasurement principle:\nBinocular, dynamic photoretinoscopy\n\nInterfaces & Power Requirements\nInterfaces:\n4 Ã— USB ports\n1 Ã— VGA output (supports 1024 Ã— 768 resolution)\nPower supply:\nAC 100 240 V, 50 60 Hz, 2.5 A (excluding monitor)\n\nEnvironmental Conditions\nOperating temperature: 10 35 Â°C (50 92 Â°F)\nStorage temperature: 0 50 Â°C (32 122 Â°F)\nRelative humidity (non-condensing):\nOperating: 20 80%\nStorage: 10 85%\n\nData Output & Logging\nMeasurements are continuously recorded into a CSV logfile, capturing:\nTimestamp (every 20 ms)\nLED brightness (percentage)\nPupil detection status (found/not found)\nPupil size (width & height in mm)\nPupil brightness (digital units 0 255)\nPurkinje reflex size & position (pixels: X & Y)\nGaze angles (horizontal & vertical in degrees)\nSpherical refraction per eye, including mean & standard deviation over last 10 frames\nInterpupillary distance in mm\nCamera horizontal angle\n\nSalient Functional Characteristics\nBinocular dynamic measurement:\nTracks continuous changes in accommodation (sphere), convergence, and pupil size for both eyes\n50 Hz real-time sampling:\nHigh temporal resolution enables precise tracking of fast dynamics\nOpen-field fixation:\nUses a hot mirror to allow naturalistic visual targets at any distance\nNon-contact operation:\nMeasurements gathered without touching the subject\nResearch-grade device:\nDesigned specifically for scientific applications investigating accommodation response times, IOL performance, convergence accommodation relationships, and neuro-ophthalmologic metrics\n\nIntegration & Output\nData can be streamed via USB or recorded to a VGA-connected monitor\nOutputs are ideal for integration into custom research setups and signal logging systems\nSalient Characteristics Plusoptix PowerRef 3 Accommodation Measurement System\nThe PowerRef 3 system must meet the following minimum salient characteristics to satisfy clinical research and operational requirements for binocular, real time accommodation and convergence measurement:\n1. Measurement Capability\nMust perform simultaneous binocular measurement of:\nRefractive state (sphere, vertical meridian)\nConvergence/vergence\nPupil size (both eyes)\nMust provide continuous, real time data acquisition suitable for dynamic accommodative and vergence analysis.\n2. Sampling and Data Output\nMust provide a minimum sampling rate of 50 Hz (20 ms intervals) to capture rapid accommodation fluctuations.\nMust support continuous data streaming and export to external computers and research software.\nMust allow real time or recorded output in spreadsheet compatible formats.\n3. Optical and System Design\nMust use infrared photorefraction technology.\nMust include an open field optical design, enabling natural fixation on targets at varying distances without the constraints of an enclosed optical path.\nMust incorporate a hot mirror target presentation system permitting both stationary and moving fixation stimuli at adjustable distances.\n4. Calibration and Reliability\nMust be engineered for long term calibration stability, requiring no routine recalibration under normal use.\nMust include durable optics and electronics suited for repeated daily research use.\n5. Fixation Target Flexibility\nMust support user selectable fixation targets, including moving or adjustable distance stimuli for controlled accommodation and vergence testing.\n6. Integration and Compatibility\nMust be compatible with standard Windows based data acquisition systems, research platforms, or laboratory PCs.\nMust allow USB or networked connection for external data handling.\n7. System Configuration\nMust include all necessary hardware, software, cables, and accessories required for full operational use upon installation.\n\nBackground: The VA-ORD-funded study Home-based Treatment of Binocular Eye Dysfunction in Veterans with Traumatic Brain Injury (Mark Walker, M.D., principal investigator) will investigate physiological mechanisms underlying near vision impairment in Veterans and will conduct a pilot study to explore the feasibility and potential efficacy of virtual-reality for customized home therapy of convergence insufficiency. This study requires robust measures of ocular accommodation, the change in the shape of the eye s lens to focus on near images. For that purpose, we require a device that can measure directly changes in lens curvature and that can do this dynamically at a high enough sample rate to measure not only the amount but also the rate of accommodation. The device must also have integrated eye tracking for simultaneous measurement of ocular vergence. The PlusOptix PowerRef3 is the only currently available device that measures accommodation directly and dynamically, is portable, and includes eye tracking to measure simultaneous convergence.\nScope: AcquisitionÂ of an automatedÂ retinoscopy-based accommodation and ocular vergence measurement device, itsÂ controlÂ software, andÂ associatedÂ measurement apparatus.Â Â Â\nThe information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications.\nIf you are interested and can provide the sought-out supplies/services, please provide the requested information indicated below. Response to this notice should include company name, address, point of contact, DUNS number, and size of business pursuant to the following questions:\nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)\n\nIs your company considered small under the NAICS code identified under this RFI? If not, is your company considered small under a related NAICS code?\n\nAre you the manufacturer or distributor of the items being referenced above (or equivalent product/solution)? What is the manufacturing country of origin of these items?\n\nIf you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).\n\nIf you re a small business and you are an authorized distributor/reseller for the items identified above (or an equivalent solution), do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\n\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number.\n\nIf you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions you are providing information for available on your schedule/contract?\n\nPlease provide general pricing of your products/solution for market research purposes.\n\nPlease submit your capabilities in regard to the salient characteristics being provided and any information pertaining to brand name or equal to items to establish capabilities for planning purposes.\nNo re-manufactures or gray market items will be acceptable. Vendor shall be an Original Equipment Manufacturer (OEM), authorized dealer, authorized distributor or authorized reseller verified by an authorization letter or other documents from the OEM.\nSUBMISSION\nResponses to this notice shall be submitted via email to kevin.peeples@va.gov and robert.blasko@va.gov referencing 36C25026Q0950 in the email. Telephone responses will not be accepted. Responses must be received no later than September 8, 2026, at 7:00am EST, (Eastern Standard Time). If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this request for information. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation.\nCLAUSES\n\nFAR Number\nTitle\nDate\n52.209-6\nPROTECTING THE GOVERNMENT S INTEREST WHEN SUBCONTRACTING WITH CONTRACTORS DEBARRED, SUSPENDED, OR PROPOSED FOR DEBARMENT\nJAN 2025\n52.212-4\nCONTRACT TERMS AND CONDITIONS-- COMMERCIAL ITEMS\nNOV 2023\n\n52.222-90\n\n52.232-33\nADDRESSING DEI DISCRIMINATION BY FEDERAL\nCONTRACTORS\nPAYMENT BY ELECTRONIC FUNDS TRANSFER SYSTEM FOR AWARD MANAGEMENT\nAPR 2026\n\nOCT 2018\n52.252-2\nCLAUSES INCORPORATED BY REFERENCE\nFEB 1998\n52.232-40\nPROVIDING ACCELERATED PAYMENTS TO SMALL BUSINESS SUBCONTRACTORS\nMAR 2023\n52.233-1\nDISPUTES\nMAY 2014\n52.233-3\nPROTEST AFTER AWARD\nAUG 1996\n852.219-76\n\n852.203-70\nVA NOTICE OF LIMITATIONS ON SUBCONTRACTING-CERTIFICATE OF COMPLIANCE FOR SUPPLIES AND PRODUCTS (DEVIATION)\n\nCOMMERCIAL ADVERTISING\nJAN 2023\n\nMAY 2018\n852.232-72\nELECTRONIC SUBMISSION OF PAYMENT REQUESTS\nNOV 2018\n852.237-70\nCONTRACTOR RESPONSIBILITIES\nOCT 2019\n\nPROVISIONS\n\n52.212-1\nINSTRUCTIONS TO OFFERORS-COMMERCIAL ITEMS\nSEP 2023\n52.212-2\nEVALUATION--COMMERCIAL ITEMS\nNOV 2021","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25026Q0950","place_of_performance":{"zip":"44106","city":{"name":"CLEVELAND"},"state":{"code":"OH"},"street":"VAMC CLEVELAND 10701 EAST BLVD.","country":{"code":"USA"}},"product_service_code":"6540"}],"due_at":"2026-09-08T11:00:00Z","due_date":"2026-09-08","closes_at":"2026-09-08T11:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-08T06:19:51.342696Z","principal_notice_id":"d3f1cb94013b4a338053516e9c32d7cf","description":{"text":"SOURCES SOUGHT NOTICE\n\nTHIS REQUEST FOR INFORMATION (RFI/Sources Sought) IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 10.002(b)(2), FAR 12.101, FAR 12.103 & FAR 12.202(a).\nDISCLAIMER\nThis request for information, sources sought (RFI/Sources Sought) is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 10.002(b)(2), FAR 12.101, FAR 12.103 & FAR 12.202(a), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nThis is NOT a solicitation announcement. This is a sources sought/RFI only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified Small Businesses under NAICS 339112, (Surgical and Medical Instrument Manufacturing industry), but does not exclude others from responding. Responses to this source sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this source sought, a solicitation announcement may be published. Responses to this source sought synopsis are not considered adequate responses for a solicitation announcement.\n\nSOURCES SOUGHT DESCRIPTION\nThe Department of Veterans Affairs, Network Contracting Office 10, Louis Stokes Cleveland VA Medical Center, is seeking sources that can provide a Accommodation Meter plusoptiX R09 (PowerRef 3) and accessories for Surgical Department Mechanical Room that meets the following:\n\nProduct/Items\nITEM NO. DESCRIPTION QUANTIYT UNIT\nOR STOCK NO.\n\nRequest purchase only of Accommodation Meter plusoptiX R09 (PowerRef 3)\n\nAccommodation Meter plusoptiX R09 (PowerRef 3) incl. Medical Power Adaptor 1 EA\n2. Software Licence RP Dynamic measurements of accommodation in sphere, convergence and pupil size changes in scotopic, mesopic and photopic conditions 1 EA\n3. Complete measurement set-up kit (includes former MIRROR, SLIDE and REST) 1 EA\n4. Shipping and Handling 1 EA\n\nSpecifications & Salient Characteristics\n\nTechnical Specifications\nRefraction (vertical meridian):\nBinocular and monocular measurement\nSpherical range: +5.00 D to 7.00 D, in increments of 0.01 D\nPupil size:\nRange: 4.0 8.0 mm, measured in 0.1 mm steps, Â±10% accuracy\nPupil distance (interpupillary distance):\nMeasured in 1.0 mm steps, Â±10% accuracy\nSampling rate:\n50 Hz (one measurement every 20 ms)\nMeasuring distance:\nStandard working distance of 1 m (Â± 5 cm)\nMeasurement principle:\nBinocular, dynamic photoretinoscopy\n\nInterfaces & Power Requirements\nInterfaces:\n4 Ã— USB ports\n1 Ã— VGA output (supports 1024 Ã— 768 resolution)\nPower supply:\nAC 100 240 V, 50 60 Hz, 2.5 A (excluding monitor)\n\nEnvironmental Conditions\nOperating temperature: 10 35 Â°C (50 92 Â°F)\nStorage temperature: 0 50 Â°C (32 122 Â°F)\nRelative humidity (non-condensing):\nOperating: 20 80%\nStorage: 10 85%\n\nData Output & Logging\nMeasurements are continuously recorded into a CSV logfile, capturing:\nTimestamp (every 20 ms)\nLED brightness (percentage)\nPupil detection status (found/not found)\nPupil size (width & height in mm)\nPupil brightness (digital units 0 255)\nPurkinje reflex size & position (pixels: X & Y)\nGaze angles (horizontal & vertical in degrees)\nSpherical refraction per eye, including mean & standard deviation over last 10 frames\nInterpupillary distance in mm\nCamera horizontal angle\n\nSalient Functional Characteristics\nBinocular dynamic measurement:\nTracks continuous changes in accommodation (sphere), convergence, and pupil size for both eyes\n50 Hz real-time sampling:\nHigh temporal resolution enables precise tracking of fast dynamics\nOpen-field fixation:\nUses a hot mirror to allow naturalistic visual targets at any distance\nNon-contact operation:\nMeasurements gathered without touching the subject\nResearch-grade device:\nDesigned specifically for scientific applications investigating accommodation response times, IOL performance, convergence accommodation relationships, and neuro-ophthalmologic metrics\n\nIntegration & Output\nData can be streamed via USB or recorded to a VGA-connected monitor\nOutputs are ideal for integration into custom research setups and signal logging systems\nSalient Characteristics Plusoptix PowerRef 3 Accommodation Measurement System\nThe PowerRef 3 system must meet the following minimum salient characteristics to satisfy clinical research and operational requirements for binocular, real time accommodation and convergence measurement:\n1. Measurement Capability\nMust perform simultaneous binocular measurement of:\nRefractive state (sphere, vertical meridian)\nConvergence/vergence\nPupil size (both eyes)\nMust provide continuous, real time data acquisition suitable for dynamic accommodative and vergence analysis.\n2. Sampling and Data Output\nMust provide a minimum sampling rate of 50 Hz (20 ms intervals) to capture rapid accommodation fluctuations.\nMust support continuous data streaming and export to external computers and research software.\nMust allow real time or recorded output in spreadsheet compatible formats.\n3. Optical and System Design\nMust use infrared photorefraction technology.\nMust include an open field optical design, enabling natural fixation on targets at varying distances without the constraints of an enclosed optical path.\nMust incorporate a hot mirror target presentation system permitting both stationary and moving fixation stimuli at adjustable distances.\n4. Calibration and Reliability\nMust be engineered for long term calibration stability, requiring no routine recalibration under normal use.\nMust include durable optics and electronics suited for repeated daily research use.\n5. Fixation Target Flexibility\nMust support user selectable fixation targets, including moving or adjustable distance stimuli for controlled accommodation and vergence testing.\n6. Integration and Compatibility\nMust be compatible with standard Windows based data acquisition systems, research platforms, or laboratory PCs.\nMust allow USB or networked connection for external data handling.\n7. System Configuration\nMust include all necessary hardware, software, cables, and accessories required for full operational use upon installation.\n\nBackground: The VA-ORD-funded study Home-based Treatment of Binocular Eye Dysfunction in Veterans with Traumatic Brain Injury (Mark Walker, M.D., principal investigator) will investigate physiological mechanisms underlying near vision impairment in Veterans and will conduct a pilot study to explore the feasibility and potential efficacy of virtual-reality for customized home therapy of convergence insufficiency. This study requires robust measures of ocular accommodation, the change in the shape of the eye s lens to focus on near images. For that purpose, we require a device that can measure directly changes in lens curvature and that can do this dynamically at a high enough sample rate to measure not only the amount but also the rate of accommodation. The device must also have integrated eye tracking for simultaneous measurement of ocular vergence. The PlusOptix PowerRef3 is the only currently available device that measures accommodation directly and dynamically, is portable, and includes eye tracking to measure simultaneous convergence.\nScope: AcquisitionÂ of an automatedÂ retinoscopy-based accommodation and ocular vergence measurement device, itsÂ controlÂ software, andÂ associatedÂ measurement apparatus.Â Â Â\nThe information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications.\nIf you are interested and can provide the sought-out supplies/services, please provide the requested information indicated below. Response to this notice should include company name, address, point of contact, DUNS number, and size of business pursuant to the following questions:\nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)\n\nIs your company considered small under the NAICS code identified under this RFI? If not, is your company considered small under a related NAICS code?\n\nAre you the manufacturer or distributor of the items being referenced above (or equivalent product/solution)? What is the manufacturing country of origin of these items?\n\nIf you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).\n\nIf you re a small business and you are an authorized distributor/reseller for the items identified above (or an equivalent solution), do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\n\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number.\n\nIf you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions you are providing information for available on your schedule/contract?\n\nPlease provide general pricing of your products/solution for market research purposes.\n\nPlease submit your capabilities in regard to the salient characteristics being provided and any information pertaining to brand name or equal to items to establish capabilities for planning purposes.\nNo re-manufactures or gray market items will be acceptable. Vendor shall be an Original Equipment Manufacturer (OEM), authorized dealer, authorized distributor or authorized reseller verified by an authorization letter or other documents from the OEM.\nSUBMISSION\nResponses to this notice shall be submitted via email to kevin.peeples@va.gov and robert.blasko@va.gov referencing 36C25026Q0950 in the email. Telephone responses will not be accepted. Responses must be received no later than September 8, 2026, at 7:00am EST, (Eastern Standard Time). If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this request for information. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation.\nCLAUSES\n\nFAR Number\nTitle\nDate\n52.209-6\nPROTECTING THE GOVERNMENT S INTEREST WHEN SUBCONTRACTING WITH CONTRACTORS DEBARRED, SUSPENDED, OR PROPOSED FOR DEBARMENT\nJAN 2025\n52.212-4\nCONTRACT TERMS AND CONDITIONS-- COMMERCIAL ITEMS\nNOV 2023\n\n52.222-90\n\n52.232-33\nADDRESSING DEI DISCRIMINATION BY FEDERAL\nCONTRACTORS\nPAYMENT BY ELECTRONIC FUNDS TRANSFER SYSTEM FOR AWARD MANAGEMENT\nAPR 2026\n\nOCT 2018\n52.252-2\nCLAUSES INCORPORATED BY REFERENCE\nFEB 1998\n52.232-40\nPROVIDING ACCELERATED PAYMENTS TO SMALL BUSINESS SUBCONTRACTORS\nMAR 2023\n52.233-1\nDISPUTES\nMAY 2014\n52.233-3\nPROTEST AFTER AWARD\nAUG 1996\n852.219-76\n\n852.203-70\nVA NOTICE OF LIMITATIONS ON SUBCONTRACTING-CERTIFICATE OF COMPLIANCE FOR SUPPLIES AND PRODUCTS (DEVIATION)\n\nCOMMERCIAL ADVERTISING\nJAN 2023\n\nMAY 2018\n852.232-72\nELECTRONIC SUBMISSION OF PAYMENT REQUESTS\nNOV 2018\n852.237-70\nCONTRACTOR RESPONSIBILITIES\nOCT 2019\n\nPROVISIONS\n\n52.212-1\nINSTRUCTIONS TO OFFERORS-COMMERCIAL ITEMS\nSEP 2023\n52.212-2\nEVALUATION--COMMERCIAL ITEMS\nNOV 2021","html":"SOURCES SOUGHT NOTICE\n\nTHIS REQUEST FOR INFORMATION (RFI/Sources Sought) IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 10.002(b)(2), FAR 12.101, FAR 12.103 & FAR 12.202(a).\nDISCLAIMER\nThis request for information, sources sought (RFI/Sources Sought) is issued solely for information and planning purposes only and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  IAW FAR 10.002(b)(2), FAR 12.101, FAR 12.103 & FAR 12.202(a), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\nThis is NOT a solicitation announcement.  This is a sources sought/RFI only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified Small Businesses under NAICS 339112, (Surgical and Medical Instrument Manufacturing industry), but does not exclude others from responding. Responses to this source sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this source sought, a solicitation announcement may be published.  Responses to this source sought synopsis are not considered adequate responses for a solicitation announcement.  \n\nSOURCES SOUGHT DESCRIPTION\nThe Department of Veterans Affairs, Network Contracting Office 10, Louis Stokes Cleveland VA Medical Center, is seeking sources that can provide a  Accommodation Meter plusoptiX R09 (PowerRef 3) and accessories  for Surgical Department Mechanical Room that meets the following: \n\nProduct/Items\nITEM NO.             DESCRIPTION                                   QUANTIYT UNIT\nOR STOCK NO.                                                        \n             \n             Request purchase only of Accommodation Meter plusoptiX R09 (PowerRef 3)\n\nAccommodation Meter plusoptiX R09 (PowerRef 3) incl. Medical Power Adaptor      1    EA\n   2. Software Licence RP Dynamic measurements of accommodation in sphere, convergence and pupil size changes in scotopic, mesopic and photopic conditions                                                                            1    EA\n   3. Complete measurement set-up kit (includes former MIRROR, SLIDE and REST)                                         1     EA\n   4. Shipping and Handling                         1     EA\n     \n\nSpecifications & Salient Characteristics\n\nTechnical Specifications\nRefraction (vertical meridian): \nBinocular and monocular measurement\nSpherical range: +5.00 D to  7.00 D, in increments of 0.01 D\nPupil size: \nRange: 4.0 8.0 mm, measured in 0.1 mm steps, Â±10% accuracy \nPupil distance (interpupillary distance): \nMeasured in 1.0 mm steps, Â±10% accuracy \nSampling rate: \n50 Hz (one measurement every 20 ms) \nMeasuring distance: \nStandard working distance of 1 m (Â± 5 cm) \nMeasurement principle: \nBinocular, dynamic photoretinoscopy\n\nInterfaces & Power Requirements\nInterfaces: \n4 Ã— USB ports\n1 Ã— VGA output (supports 1024 Ã— 768 resolution) \nPower supply: \nAC 100 240 V, 50 60 Hz, 2.5 A (excluding monitor) \n\nEnvironmental Conditions\nOperating temperature: 10 35 Â°C (50 92 Â°F)\nStorage temperature: 0 50 Â°C (32 122 Â°F)\nRelative humidity (non-condensing): \nOperating: 20 80%\nStorage: 10 85%\n\nData Output & Logging\nMeasurements are continuously recorded into a CSV  logfile,  capturing:\nTimestamp (every 20 ms)\nLED brightness (percentage)\nPupil detection status (found/not found)\nPupil size (width & height in mm)\nPupil brightness (digital units 0 255)\nPurkinje reflex size & position (pixels: X & Y)\nGaze angles (horizontal & vertical in degrees)\nSpherical refraction per eye, including mean & standard deviation over last 10 frames\nInterpupillary distance in mm\nCamera horizontal angle \n\nSalient Functional Characteristics\nBinocular dynamic measurement: \nTracks continuous changes in accommodation (sphere), convergence, and pupil size for both eyes \n50 Hz real-time sampling: \nHigh temporal resolution enables precise tracking of fast dynamics \nOpen-field fixation: \nUses a hot mirror to allow naturalistic visual targets at any distance \nNon-contact operation: \nMeasurements gathered without touching the subject \nResearch-grade device: \nDesigned specifically for scientific applications investigating accommodation response times, IOL performance, convergence accommodation relationships, and neuro-ophthalmologic metrics \n\nIntegration & Output\nData can be streamed via USB or recorded to a VGA-connected monitor\nOutputs are ideal for integration into custom research setups and signal logging systems\nSalient Characteristics   Plusoptix PowerRef 3 Accommodation Measurement System\nThe PowerRef 3 system must meet the following minimum salient characteristics to satisfy clinical research and operational requirements for binocular, real time accommodation and convergence measurement:\n1. Measurement Capability\nMust perform simultaneous binocular measurement of:\n  Refractive state (sphere, vertical meridian)\n  Convergence/vergence\n  Pupil size (both eyes)\nMust provide continuous, real time data acquisition suitable for dynamic accommodative and vergence analysis.\n2. Sampling and Data Output\nMust provide a minimum sampling rate of 50 Hz (20 ms intervals) to capture rapid accommodation fluctuations.\nMust support continuous data streaming and export to external computers and research software.\nMust allow real time or recorded output in spreadsheet compatible formats.\n3. Optical and System Design\nMust use infrared photorefraction technology.\nMust include an open field optical design, enabling natural fixation on targets at varying distances without the constraints of an enclosed optical path.\nMust incorporate a hot mirror target presentation system permitting both stationary and moving fixation stimuli at adjustable distances.\n4. Calibration and Reliability\nMust be engineered for long term calibration stability, requiring no routine recalibration under normal use.\nMust include durable optics and electronics suited for repeated daily research use.\n5. Fixation Target Flexibility\nMust support user selectable fixation targets, including moving or adjustable distance stimuli for controlled accommodation and vergence testing.\n6. Integration and Compatibility\nMust be compatible with standard Windows based data acquisition systems, research platforms, or laboratory PCs.\nMust allow USB or networked connection for external data handling.\n7. System Configuration\nMust include all necessary hardware, software, cables, and accessories required for full operational use upon installation.\n\nBackground: The VA-ORD-funded study  Home-based Treatment of Binocular Eye Dysfunction in Veterans with Traumatic Brain Injury  (Mark Walker, M.D., principal investigator) will investigate physiological mechanisms underlying near vision impairment in Veterans and will conduct a pilot study to explore the feasibility and potential efficacy of virtual-reality for customized home therapy of convergence insufficiency. This study requires robust measures of ocular accommodation, the change in the shape of the eye s lens to focus on near images. For that purpose, we require a device that can measure directly changes in lens curvature and that can do this dynamically at a high enough sample rate to measure not only the amount but also the rate of accommodation. The device must also have integrated eye tracking for simultaneous measurement of ocular vergence. The PlusOptix PowerRef3 is the only currently available device that measures accommodation directly and dynamically, is portable, and includes eye tracking to measure simultaneous convergence.\nScope: AcquisitionÂ of an automatedÂ retinoscopy-based accommodation and ocular vergence measurement device, itsÂ controlÂ software, andÂ associatedÂ measurement apparatus.Â Â Â \nThe information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications. \nIf you are interested and can provide the sought-out supplies/services, please provide the requested information indicated below. Response to this notice should include company name, address, point of contact, DUNS number, and size of business pursuant to the following questions:  \nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)\n\nIs your company considered small under the NAICS code identified under this RFI? If not, is your company considered small under a related NAICS code?\n\nAre you the manufacturer or distributor of the items being referenced above (or equivalent product/solution)? What is the manufacturing country of origin of these items?\n\nIf you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).\n\nIf you re a small business and you are an authorized distributor/reseller for the items identified above (or an equivalent solution), do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\n\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number.\n\nIf you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions you are providing information for available on your schedule/contract?\n\nPlease provide general pricing of your products/solution for market research purposes.\n\nPlease submit your capabilities in regard to the salient characteristics being provided and any information pertaining to  brand name or equal to  items to establish capabilities for planning purposes.  \nNo re-manufactures or gray market items will be acceptable. Vendor shall be an Original Equipment Manufacturer (OEM), authorized dealer, authorized distributor or authorized reseller verified by an authorization letter or other documents from the OEM.\nSUBMISSION\nResponses to this notice shall be submitted via email to kevin.peeples@va.gov and robert.blasko@va.gov referencing 36C25026Q0950 in the email. Telephone responses will not be accepted.  Responses must be received no later than September 8, 2026, at 7:00am EST, (Eastern Standard Time). If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this request for information.  Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation.\nCLAUSES\n\n\n\n\n\n\nFAR Number\nTitle\nDate\n52.209-6\nPROTECTING THE GOVERNMENT S INTEREST WHEN SUBCONTRACTING WITH CONTRACTORS DEBARRED, SUSPENDED, OR PROPOSED FOR DEBARMENT\nJAN 2025\n52.212-4\nCONTRACT TERMS AND CONDITIONS-- COMMERCIAL ITEMS\nNOV 2023\n\n\n\n52.222-90\n\n52.232-33\nADDRESSING DEI DISCRIMINATION BY FEDERAL\nCONTRACTORS\nPAYMENT BY ELECTRONIC FUNDS TRANSFER   SYSTEM FOR AWARD MANAGEMENT \nAPR 2026\n\nOCT 2018\n52.252-2\nCLAUSES INCORPORATED BY REFERENCE\nFEB 1998\n52.232-40\nPROVIDING ACCELERATED PAYMENTS TO SMALL BUSINESS SUBCONTRACTORS\nMAR 2023\n52.233-1\nDISPUTES\nMAY 2014\n52.233-3\nPROTEST AFTER AWARD\nAUG 1996\n852.219-76\n\n\n852.203-70\nVA NOTICE OF LIMITATIONS ON SUBCONTRACTING-CERTIFICATE OF COMPLIANCE FOR SUPPLIES AND PRODUCTS (DEVIATION)\n\nCOMMERCIAL ADVERTISING\nJAN 2023\n\n\nMAY 2018\n852.232-72\nELECTRONIC SUBMISSION OF PAYMENT REQUESTS\nNOV 2018\n852.237-70\nCONTRACTOR RESPONSIBILITIES\nOCT 2019\n\n\n\n\nPROVISIONS\n\n\n\n\n\n\n\n52.212-1\nINSTRUCTIONS TO OFFERORS-COMMERCIAL ITEMS\nSEP 2023\n52.212-2\nEVALUATION--COMMERCIAL ITEMS\nNOV 2021","origin":"detail"},"contacts":[{"fax":"NA","name":"KEVIN PEEPLES","role":"primary","email":"Kevin.peeples@va.gov","phone":"216-416-1600","title":"CONTRACT SPECIALIST"}],"place_of_performance":{"zip":"44106","city":{"name":"CLEVELAND"},"state":{"code":"OH"},"street":"VAMC CLEVELAND 10701 EAST BLVD.","country":{"code":"USA"}},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"naics_codes":["339112"],"award":null,"attachments":[{"resource_id":"641793c4870f417f81742fd58c9e15e9","name":"36C25026Q0950.docx","kind":"file","mime_type":".docx","size_bytes":39670,"posted_at":"2026-08-27T15:32:54.167Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/641793c4870f417f81742fd58c9e15e9/download","mirrored":false}],"awards":[],"related":[{"key":"36C25027Q0014","latest_notice_id":"b13cc87179e947e7b42da2de44a6bde1","title":"J061--541 Electrical Power Distribution Equipment Testing, Inspection, and Maintenance - VAMC Cleveland","solicitation_number":"36C25027Q0014","notice_type":"k","first_type":"k","first_posted":"2026-10-09","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"238210","psc":"J061","set_aside":"SBA","state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C25027Q0123","latest_notice_id":"fb53a332644a4c8fa983bf28c8643d2d","title":"S222--Sources Sought - Hazardous Waste Removal/Disposal Northeast Ohio VA Healthcare System - Cleveland, OH","solicitation_number":"36C25027Q0123","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T18:30:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"562112","psc":"S222","set_aside":null,"state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C25027B0009","latest_notice_id":"85b83d408f1f422885991142c2734b45","title":"Z1DA--FY27 NRM - VISN Base Modernize Nurse Call - 539-23-101","solicitation_number":"36C25027B0009","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"},{"key":"36C25027B0008","latest_notice_id":"5afe716a38494a6f84b1e84205805f86","title":"Z1DA--FY27 NRM - VISN Base Install Roof Equipment Railings - 539-22-206","solicitation_number":"36C25027B0008","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"},{"key":"36C25027B0005","latest_notice_id":"2cb4a6354be04cc89c5d6125945b1892","title":"Z1DA--***FY27 Requirement*** First Floor X Ray - Room CC157 553-CSI-022","solicitation_number":"36C25027B0005","notice_type":"p","first_type":"p","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"MI","county":"26163","county_name":"Wayne County","city":"2622000","city_name":"Detroit","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"}],"similar_open":[{"key":"W911S227U0200","latest_notice_id":"153aef7d00e740188276deb8422a2297","title":"Automated External Defibrillator (AED)","solicitation_number":"W911S227U0200","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T20:15:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:15:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24727Q0119","latest_notice_id":"81776fecabf149c9867d6253acdc2478","title":"Vivarium Tunnel Washer","solicitation_number":"36C24727Q0119","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"339112","psc":"6640","set_aside":null,"state":"GA","county":"13089","county_name":"DeKalb County","city":"1322052","city_name":"Decatur","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C10X27Q0025","latest_notice_id":"8c404062fbbc4212bb93120ad204ee50","title":"6515--NX EQ Microscope, Light, Operating, Hand/Plastic Surgery (VA-27-00017958)","solicitation_number":"36C10X27Q0025","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"}],"similar_open_total":15,"indexable":false}