{"canonical":"https://sealedbidder.com/opportunities/36c25026q0896","key":"36C25026Q0896","url":"https://sealedbidder.com/opportunities/36c25026q0896","title":"6515--541-26-3-250-0303 - Olympus BX43 Pathology Microscope","solicitation_number":"36C25026Q0896","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-08-20T20:00:00Z","first_posted":"2026-08-18","last_posted":"2026-08-18","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"339112","psc":"6515","set_aside":"SBA","place_state":"OH","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"39035","place_county_name":"Cuyahoga County","place_city":"3916000","place_city_name":"Cleveland","winner":null,"award_amount":null,"publications":[{"notice_id":"1c77e3eb516a4a4b8af19997d7f6edb7","title":"6515--541-26-3-250-0303 - Olympus BX43 Pathology Microscope","solicitation_number":"36C25026Q0896","notice_type":"r","base_type":"r","posted":"2026-08-18","posted_at":"2026-08-18T09:38:45.598Z","due_at":"2026-08-20T20:00:00Z","due_date":"2026-08-20","cancelled":false,"archived":true,"archive_date":"2026-10-19","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/1c77e3eb516a4a4b8af19997d7f6edb7/view","enriched":true,"history":[{"index":1,"title":"6515--541-26-3-250-0303 - Olympus BX43 Pathology Microscope","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-18T09:38:45.598Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"1c77e3eb516a4a4b8af19997d7f6edb7","solicitation_number":"36C25026Q0896"}]}],"latest_notice_id":"1c77e3eb516a4a4b8af19997d7f6edb7","first_type":"r","notices":[{"dates":{"posted":"2026-08-18","posted_at":"2026-08-18T09:38:45.598Z","created_at":"2026-08-18T09:38:17.229Z","modified_at":"2026-08-18T09:38:45.598Z","response_deadline":{"raw":"2026-08-20T16:00:00-04:00","utc":"2026-08-20T20:00:00Z","date":"2026-08-20","time":"16:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/1c77e3eb516a4a4b8af19997d7f6edb7/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"6515--541-26-3-250-0303 - Olympus BX43 Pathology Microscope","agency":{"office":{"code":"36C250","name":"250-NETWORK CONTRACT OFFICE 10 (36C250)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"publication":"published","archive_date":"2026-10-19","archive_type":"auto_custom"},"history":[{"index":1,"title":"6515--541-26-3-250-0303 - Olympus BX43 Pathology Microscope","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-18T09:38:45.598Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"1c77e3eb516a4a4b8af19997d7f6edb7","solicitation_number":"36C25026Q0896"}],"contacts":[{"fax":"NA","name":"KEVIN PEEPLES","role":"primary","email":"Kevin.peeples@va.gov","phone":"216-416-1600","title":"CONTRACT SPECIALIST"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"1c77e3eb516a4a4b8af19997d7f6edb7","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"1c77e3eb516a4a4b8af19997d7f6edb7","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-18T01:29:42.285780967Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"6490cb193b94cfd3760ea9efa9c8cc16643016a32317be7db4dd71de6f7e3de4","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-09-15T22:52:52.472456Z"},"description":{"html":"SOURCES SOUGHT NOTICE\n\nTHIS REQUEST FOR INFORMATION (RFI/Sources Sought) IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 10.002(b)(2), FAR 12.101, FAR 12.103 & FAR 12.202(a).\nDISCLAIMER\nThis request for information, sources sought (RFI/Sources Sought) is issued solely for information and planning purposes only and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  IAW FAR 10.002(b)(2), FAR 12.101, FAR 12.103 & FAR 12.202(a), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\nThis is NOT a solicitation announcement.  This is a sources sought/RFI only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified Small Businesses under NAICS 339112, (Surgical and Medical Instrument Manufacturing industry), but does not exclude others from responding. Responses to this source sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this source sought, a solicitation announcement may be published.  Responses to this source sought synopsis are not considered adequate responses for a solicitation announcement.  \n\nSOURCES SOUGHT DESCRIPTION\nThe Department of Veterans Affairs, Network Contracting Office 10, Louis Stokes Cleveland VA Medical Center, is seeking sources that can provide a  BX43 Cytology Microscope and accessories  for Surgical Department Mechanical Room that meets the following: \n\nProduct/Items\nITEM NO.             DESCRIPTION                                   QUANTITY UNIT\nOR STOCK NO.                                                        \n             \n             Request purchase only of BX43 Pathology Microscope and accessories\n\nBX43-1-3 Microscope frame     2    EA\n   2. True color LED light source for BX43F, BX46F and BX63F                                                                                                      2    EA\n   3. UYCP-11; US Style 3-prong cord               2     EA\n   4. U-TTR-2 tiltable trinocular ergo                                     2     EA\n                         5. WHN10X-H-1-8 eyepiece NOSEPIECE,REVERSE,ANALYZER SLOT,RMS THREAD                                                                                              4     EA\n                         6. U-D6RE;6 POSITION                                                                  2     EA\n                         7. PLN2X/0,06 Plan Achromat, WD=5,8, NA=0,06 CC=-              2     EA\n                          8. PLN4X/0.1 Plan Achromat Objective 4x                                    2     EA\n                          9. PLN10X/0,25 Plan Achromat 10x,                                              2     EA\n                          10. PLN20X/0.4 Plan Achromat Objective 10 PLN20X/0.4 Plan Achromat Objective 20x                                                                                                             2    EA\n                           11. PLN40X/0,65 Plan Achromat 40x, WD=0,6, NA=0,65, CC=0,17\n                                                                                                                                    2   EA\n                           12. PLCN60X-1-7 Plan achromat objective\n             60X/0.8, WD 0.2                                                                                           2   EA\n                           13. Swing-out condenser, NA 0.9-0.17, with white contrast cap   2   EA\n                           14 U-SVRB-4; RIGHT HAND MECHANICAL STAGE, RACKLESS, LONG STALK                                                                                                           2   EA\n                          15. U-HLDT-4; LEFT RELEASE SLIDE HOLDER, DOUBLE SLIDE, THICK                                                                                                                       2   EA\n                          16. E9703006; DP23 1/1.8\" 6.4MP color CMOS, 2.4um, 45fps, incl. USB3.1 cable (2.9m)                                                                                                               2  EA\n                          17. cellSens Entry Electronic License                                             2   EA\n                          18 U-TV0.5XC-3-8 C-mount camera adapter                                 2   EA\n                          19. U-ANT; ANALYZER FOR TRANSMITTED                         2   EA\n             LIGHT, FITS IN NOSEPI SLIDER\n                 20. Polarizer For Transmitted Light, 45mm Diameter, Fits in BX Light Well\n                                                                                                                               2   EA\n                  21 COVER-018; DUST COVER, HOOD TYPE FOR BX2 MICROSCOPES\n                                                                                                                               2   EA\n                  22. SHIPPING AND HANDLING CHARGE                                    1 EA\n                  23. INCLUDES ON-SITE INSTALLATION, TRAINING & CALIBRATION\n                                                                                                                                1   EA\n\nOptical and Imaging Performance:\nUIS2 infinity-corrected optical system\nPlan Apochromat or Plan Fluorite objectives optimized for cytology applications\nHigh numerical aperture objectives suitable for oil immersion cytopathology\n100x oil immersion capability\nWide field number (FN 22 or greater)\nHigh-resolution visualization suitable for evaluation of cellular morphology, cytologic abnormalities, infectious organisms, and neoplastic processes\nOEM camera adapter compatibility for integration with existing digital imaging systems\nIllumination System:\nTrue Color LED light source compatible with BX43F, BX46F, and BX63F\nDaylight-balanced illumination to support accurate cytologic color interpretation\nFlicker-free, stable output\nLED lifespan   20,000 hours\nIntensity memory function\nUniform illumination across full field of view\nErgonomic and Mechanical Features:\nErgonomic observation tube with adjustable inclination\nLow-position coaxial focus knobs\nCoarse and fine focus with tension adjustment\nPrecision mechanical stage with fine movement control\nStage inserts compatible with cytology slide preparation\nConfiguration optimized for prolonged microscopic review\n Required OEM Accessories and Components:\nThe Contractor shall provide all OEM components necessary to ensure full functionality and activation, including but not limited to:\nProprietary stage inserts\nLight modules\nCamera adapters\nImmersion oil kits (OEM approved)\nDust covers\nPower cords\nCalibration and setup materials\nRequired mounting hardware\nAny additional OEM components necessary for clinical operation\nAll components must be new, OEM-manufactured, and fully compatible with existing Evident BX-series microscopes currently deployed within the laboratory.\nInteroperability Requirements:\nThe Cytology Section is standardized on the Evident BX-series microscope platform. All diagnostic workflows, imaging protocols, training materials, and maintenance programs are built upon this system.\nThe requested microscopes are additional to the currently deployed fleet and must:\nIntegrate seamlessly with existing BX-series equipment\nMaintain optical consistency across the microscope fleet\nPreserve manufacturer warranty protections\nSupport existing service contracts and maintenance protocols\nRequire no retraining due to platform change\nNon-OEM or alternate-brand equipment would:\nDisrupt standardized diagnostic workflow\nIntroduce optical variability affecting diagnostic consistency\nInvalidate manufacturer warranties\nRequire retraining of cytotechnologists and pathologists\nUndermine fleet uniformity and serviceability\n\nWarranty:\nEquipment shall include the manufacturer s standard warranty covering optical, mechanical, and illumination systems for a minimum of one (1) year.\n3. BACKGROUND  \nThe Department of Veterans Affairs Northeast Ohio Healthcare System (VANEOHS) has an immediate requirement for the procurement of two (2) brand name Evident (formerly Olympus) BX43-1-3 cytology microscopes, inclusive of the True Color LED light source compatible with BX43F, BX46F, and BX63F platforms, and all required Original Equipment Manufacturer (OEM) components and accessories necessary for full clinical activation and use.\n\nThe requested microscopes are additional units to the currently deployed Evident BX-series microscopes within the Cytology Section of Pathology & Laboratory Management Services (PALMS). The laboratory s diagnostic workflows, digital imaging systems, standardized operating procedures, educational protocols, and preventative maintenance programs are fully based upon the Evident BX-series platform.\nThe Cytology laboratory s diagnostic workflows, digital imaging systems, standardized operating procedures, educational platforms, and preventative maintenance programs are built upon the BX-series architecture.\nThe Cytology Section performs high-resolution visualization and evaluation of:\nCellular morphology\nCytological abnormalities\nMicrobiological organisms\nInflammatory processes\nNeoplastic pathologies\nThese diagnostic evaluations are mission-critical to accurate, timely, and actionable patient diagnoses.\nThis acquisition is required to maintain full operational capacity, mitigate diagnostic backlog, maximize utilization of existing Government-owned assets, and ensure uninterrupted cytopathology services.\n4. SCOPE \nThe Contractor shall provide two (2) new, current production BX43-1-3 microscopes, inclusive of the True Color LED light source and all requested and associated OEM components, accessories, modules, assemblies, and consumables required for immediate clinical deployment within the Cytology Section. The Contractor shall provide on-site installation, configuration, and operational verification of all microscopes and associated OEM components at the Louis Stokes Cleveland VA Medical Center, Pathology & Laboratory Management Services   Cytology Section. Installation shall include full assembly, alignment of optical components, calibration of the illumination system, verification of mechanical stage functionality, confirmation of imaging integration (if applicable), and validation of overall system performance for clinical diagnostic use. All equipment shall be fully operational and ready for immediate patient care application upon completion of installation. Any deficiencies identified during installation or inspection shall be corrected by the Contractor at no additional cost to the Government prior to final acceptance.\n\nThe microscopes and components shall meet or exceed the following operational, optical, interoperability, and performance requirements:\n If you are interested and can provide the sought-out supplies/services, please provide the requested information indicated below. Response to this notice should include company name, address, point of contact, DUNS number, and size of business pursuant to the following questions:  \nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)\n\nIs your company considered small under the NAICS code identified under this RFI? If not, is your company considered small under a related NAICS code?\n\nAre you the manufacturer or distributor of the items being referenced above (or equivalent product/solution)? What is the manufacturing country of origin of these items?\n\nIf you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).\n\nIf you re a small business and you are an authorized distributor/reseller for the items identified above (or an equivalent solution), do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\n\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number.\n\nIf you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions you are providing information for available on your schedule/contract?\n\nPlease provide general pricing of your products/solution for market research purposes.\n\nPlease submit your capabilities in regard to the salient characteristics being provided and any information pertaining to  brand name or equal to  items to establish capabilities for planning purposes.  \nNo re-manufactures or gray market items will be acceptable. Vendor shall be an Original Equipment Manufacturer (OEM), authorized dealer, authorized distributor or authorized reseller verified by an authorization letter or other documents from the OEM.\nSUBMISSION\nResponses to this notice shall be submitted via email to kevin.peeples@va.gov. Telephone responses shall not be accepted.  Responses must be received no later than August 20, 2026, at 4:00pm EST, (Eastern Standard Time). If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this request for information.  Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation.","text":"SOURCES SOUGHT NOTICE\n\nTHIS REQUEST FOR INFORMATION (RFI/Sources Sought) IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 10.002(b)(2), FAR 12.101, FAR 12.103 & FAR 12.202(a).\nDISCLAIMER\nThis request for information, sources sought (RFI/Sources Sought) is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 10.002(b)(2), FAR 12.101, FAR 12.103 & FAR 12.202(a), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nThis is NOT a solicitation announcement. This is a sources sought/RFI only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified Small Businesses under NAICS 339112, (Surgical and Medical Instrument Manufacturing industry), but does not exclude others from responding. Responses to this source sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this source sought, a solicitation announcement may be published. Responses to this source sought synopsis are not considered adequate responses for a solicitation announcement.\n\nSOURCES SOUGHT DESCRIPTION\nThe Department of Veterans Affairs, Network Contracting Office 10, Louis Stokes Cleveland VA Medical Center, is seeking sources that can provide a BX43 Cytology Microscope and accessories for Surgical Department Mechanical Room that meets the following:\n\nProduct/Items\nITEM NO. DESCRIPTION QUANTITY UNIT\nOR STOCK NO.\n\nRequest purchase only of BX43 Pathology Microscope and accessories\n\nBX43-1-3 Microscope frame 2 EA\n2. True color LED light source for BX43F, BX46F and BX63F 2 EA\n3. UYCP-11; US Style 3-prong cord 2 EA\n4. U-TTR-2 tiltable trinocular ergo 2 EA\n5. WHN10X-H-1-8 eyepiece NOSEPIECE,REVERSE,ANALYZER SLOT,RMS THREAD 4 EA\n6. U-D6RE;6 POSITION 2 EA\n7. PLN2X/0,06 Plan Achromat, WD=5,8, NA=0,06 CC=- 2 EA\n8. PLN4X/0.1 Plan Achromat Objective 4x 2 EA\n9. PLN10X/0,25 Plan Achromat 10x, 2 EA\n10. PLN20X/0.4 Plan Achromat Objective 10 PLN20X/0.4 Plan Achromat Objective 20x 2 EA\n11. PLN40X/0,65 Plan Achromat 40x, WD=0,6, NA=0,65, CC=0,17\n2 EA\n12. PLCN60X-1-7 Plan achromat objective\n60X/0.8, WD 0.2 2 EA\n13. Swing-out condenser, NA 0.9-0.17, with white contrast cap 2 EA\n14 U-SVRB-4; RIGHT HAND MECHANICAL STAGE, RACKLESS, LONG STALK 2 EA\n15. U-HLDT-4; LEFT RELEASE SLIDE HOLDER, DOUBLE SLIDE, THICK 2 EA\n16. E9703006; DP23 1/1.8\" 6.4MP color CMOS, 2.4um, 45fps, incl. USB3.1 cable (2.9m) 2 EA\n17. cellSens Entry Electronic License 2 EA\n18 U-TV0.5XC-3-8 C-mount camera adapter 2 EA\n19. U-ANT; ANALYZER FOR TRANSMITTED 2 EA\nLIGHT, FITS IN NOSEPI SLIDER\n20. Polarizer For Transmitted Light, 45mm Diameter, Fits in BX Light Well\n2 EA\n21 COVER-018; DUST COVER, HOOD TYPE FOR BX2 MICROSCOPES\n2 EA\n22. SHIPPING AND HANDLING CHARGE 1 EA\n23. INCLUDES ON-SITE INSTALLATION, TRAINING & CALIBRATION\n1 EA\n\nOptical and Imaging Performance:\nUIS2 infinity-corrected optical system\nPlan Apochromat or Plan Fluorite objectives optimized for cytology applications\nHigh numerical aperture objectives suitable for oil immersion cytopathology\n100x oil immersion capability\nWide field number (FN 22 or greater)\nHigh-resolution visualization suitable for evaluation of cellular morphology, cytologic abnormalities, infectious organisms, and neoplastic processes\nOEM camera adapter compatibility for integration with existing digital imaging systems\nIllumination System:\nTrue Color LED light source compatible with BX43F, BX46F, and BX63F\nDaylight-balanced illumination to support accurate cytologic color interpretation\nFlicker-free, stable output\nLED lifespan 20,000 hours\nIntensity memory function\nUniform illumination across full field of view\nErgonomic and Mechanical Features:\nErgonomic observation tube with adjustable inclination\nLow-position coaxial focus knobs\nCoarse and fine focus with tension adjustment\nPrecision mechanical stage with fine movement control\nStage inserts compatible with cytology slide preparation\nConfiguration optimized for prolonged microscopic review\nRequired OEM Accessories and Components:\nThe Contractor shall provide all OEM components necessary to ensure full functionality and activation, including but not limited to:\nProprietary stage inserts\nLight modules\nCamera adapters\nImmersion oil kits (OEM approved)\nDust covers\nPower cords\nCalibration and setup materials\nRequired mounting hardware\nAny additional OEM components necessary for clinical operation\nAll components must be new, OEM-manufactured, and fully compatible with existing Evident BX-series microscopes currently deployed within the laboratory.\nInteroperability Requirements:\nThe Cytology Section is standardized on the Evident BX-series microscope platform. All diagnostic workflows, imaging protocols, training materials, and maintenance programs are built upon this system.\nThe requested microscopes are additional to the currently deployed fleet and must:\nIntegrate seamlessly with existing BX-series equipment\nMaintain optical consistency across the microscope fleet\nPreserve manufacturer warranty protections\nSupport existing service contracts and maintenance protocols\nRequire no retraining due to platform change\nNon-OEM or alternate-brand equipment would:\nDisrupt standardized diagnostic workflow\nIntroduce optical variability affecting diagnostic consistency\nInvalidate manufacturer warranties\nRequire retraining of cytotechnologists and pathologists\nUndermine fleet uniformity and serviceability\n\nWarranty:\nEquipment shall include the manufacturer s standard warranty covering optical, mechanical, and illumination systems for a minimum of one (1) year.\n3. BACKGROUND\nThe Department of Veterans Affairs Northeast Ohio Healthcare System (VANEOHS) has an immediate requirement for the procurement of two (2) brand name Evident (formerly Olympus) BX43-1-3 cytology microscopes, inclusive of the True Color LED light source compatible with BX43F, BX46F, and BX63F platforms, and all required Original Equipment Manufacturer (OEM) components and accessories necessary for full clinical activation and use.\n\nThe requested microscopes are additional units to the currently deployed Evident BX-series microscopes within the Cytology Section of Pathology & Laboratory Management Services (PALMS). The laboratory s diagnostic workflows, digital imaging systems, standardized operating procedures, educational protocols, and preventative maintenance programs are fully based upon the Evident BX-series platform.\nThe Cytology laboratory s diagnostic workflows, digital imaging systems, standardized operating procedures, educational platforms, and preventative maintenance programs are built upon the BX-series architecture.\nThe Cytology Section performs high-resolution visualization and evaluation of:\nCellular morphology\nCytological abnormalities\nMicrobiological organisms\nInflammatory processes\nNeoplastic pathologies\nThese diagnostic evaluations are mission-critical to accurate, timely, and actionable patient diagnoses.\nThis acquisition is required to maintain full operational capacity, mitigate diagnostic backlog, maximize utilization of existing Government-owned assets, and ensure uninterrupted cytopathology services.\n4. SCOPE\nThe Contractor shall provide two (2) new, current production BX43-1-3 microscopes, inclusive of the True Color LED light source and all requested and associated OEM components, accessories, modules, assemblies, and consumables required for immediate clinical deployment within the Cytology Section. The Contractor shall provide on-site installation, configuration, and operational verification of all microscopes and associated OEM components at the Louis Stokes Cleveland VA Medical Center, Pathology & Laboratory Management Services Cytology Section. Installation shall include full assembly, alignment of optical components, calibration of the illumination system, verification of mechanical stage functionality, confirmation of imaging integration (if applicable), and validation of overall system performance for clinical diagnostic use. All equipment shall be fully operational and ready for immediate patient care application upon completion of installation. Any deficiencies identified during installation or inspection shall be corrected by the Contractor at no additional cost to the Government prior to final acceptance.\n\nThe microscopes and components shall meet or exceed the following operational, optical, interoperability, and performance requirements:\nIf you are interested and can provide the sought-out supplies/services, please provide the requested information indicated below. Response to this notice should include company name, address, point of contact, DUNS number, and size of business pursuant to the following questions:\nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)\n\nIs your company considered small under the NAICS code identified under this RFI? If not, is your company considered small under a related NAICS code?\n\nAre you the manufacturer or distributor of the items being referenced above (or equivalent product/solution)? What is the manufacturing country of origin of these items?\n\nIf you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).\n\nIf you re a small business and you are an authorized distributor/reseller for the items identified above (or an equivalent solution), do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\n\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number.\n\nIf you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions you are providing information for available on your schedule/contract?\n\nPlease provide general pricing of your products/solution for market research purposes.\n\nPlease submit your capabilities in regard to the salient characteristics being provided and any information pertaining to brand name or equal to items to establish capabilities for planning purposes.\nNo re-manufactures or gray market items will be acceptable. Vendor shall be an Original Equipment Manufacturer (OEM), authorized dealer, authorized distributor or authorized reseller verified by an authorization letter or other documents from the OEM.\nSUBMISSION\nResponses to this notice shall be submitted via email to kevin.peeples@va.gov. Telephone responses shall not be accepted. Responses must be received no later than August 20, 2026, at 4:00pm EST, (Eastern Standard Time). If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this request for information. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25026Q0896","place_of_performance":{"zip":"44106","city":{"name":"CLEVELAND"},"state":{"code":"OH"},"street":"VAMC CLEVELAND 10701 EAST BLVD.","country":{"code":"USA"}},"product_service_code":"6515"}],"due_at":"2026-08-20T20:00:00Z","due_date":"2026-08-20","closes_at":"2026-08-20T20:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-20T06:22:28.379179Z","principal_notice_id":"1c77e3eb516a4a4b8af19997d7f6edb7","description":{"text":"SOURCES SOUGHT NOTICE\n\nTHIS REQUEST FOR INFORMATION (RFI/Sources Sought) IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 10.002(b)(2), FAR 12.101, FAR 12.103 & FAR 12.202(a).\nDISCLAIMER\nThis request for information, sources sought (RFI/Sources Sought) is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 10.002(b)(2), FAR 12.101, FAR 12.103 & FAR 12.202(a), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nThis is NOT a solicitation announcement. This is a sources sought/RFI only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified Small Businesses under NAICS 339112, (Surgical and Medical Instrument Manufacturing industry), but does not exclude others from responding. Responses to this source sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this source sought, a solicitation announcement may be published. Responses to this source sought synopsis are not considered adequate responses for a solicitation announcement.\n\nSOURCES SOUGHT DESCRIPTION\nThe Department of Veterans Affairs, Network Contracting Office 10, Louis Stokes Cleveland VA Medical Center, is seeking sources that can provide a BX43 Cytology Microscope and accessories for Surgical Department Mechanical Room that meets the following:\n\nProduct/Items\nITEM NO. DESCRIPTION QUANTITY UNIT\nOR STOCK NO.\n\nRequest purchase only of BX43 Pathology Microscope and accessories\n\nBX43-1-3 Microscope frame 2 EA\n2. True color LED light source for BX43F, BX46F and BX63F 2 EA\n3. UYCP-11; US Style 3-prong cord 2 EA\n4. U-TTR-2 tiltable trinocular ergo 2 EA\n5. WHN10X-H-1-8 eyepiece NOSEPIECE,REVERSE,ANALYZER SLOT,RMS THREAD 4 EA\n6. U-D6RE;6 POSITION 2 EA\n7. PLN2X/0,06 Plan Achromat, WD=5,8, NA=0,06 CC=- 2 EA\n8. PLN4X/0.1 Plan Achromat Objective 4x 2 EA\n9. PLN10X/0,25 Plan Achromat 10x, 2 EA\n10. PLN20X/0.4 Plan Achromat Objective 10 PLN20X/0.4 Plan Achromat Objective 20x 2 EA\n11. PLN40X/0,65 Plan Achromat 40x, WD=0,6, NA=0,65, CC=0,17\n2 EA\n12. PLCN60X-1-7 Plan achromat objective\n60X/0.8, WD 0.2 2 EA\n13. Swing-out condenser, NA 0.9-0.17, with white contrast cap 2 EA\n14 U-SVRB-4; RIGHT HAND MECHANICAL STAGE, RACKLESS, LONG STALK 2 EA\n15. U-HLDT-4; LEFT RELEASE SLIDE HOLDER, DOUBLE SLIDE, THICK 2 EA\n16. E9703006; DP23 1/1.8\" 6.4MP color CMOS, 2.4um, 45fps, incl. USB3.1 cable (2.9m) 2 EA\n17. cellSens Entry Electronic License 2 EA\n18 U-TV0.5XC-3-8 C-mount camera adapter 2 EA\n19. U-ANT; ANALYZER FOR TRANSMITTED 2 EA\nLIGHT, FITS IN NOSEPI SLIDER\n20. Polarizer For Transmitted Light, 45mm Diameter, Fits in BX Light Well\n2 EA\n21 COVER-018; DUST COVER, HOOD TYPE FOR BX2 MICROSCOPES\n2 EA\n22. SHIPPING AND HANDLING CHARGE 1 EA\n23. INCLUDES ON-SITE INSTALLATION, TRAINING & CALIBRATION\n1 EA\n\nOptical and Imaging Performance:\nUIS2 infinity-corrected optical system\nPlan Apochromat or Plan Fluorite objectives optimized for cytology applications\nHigh numerical aperture objectives suitable for oil immersion cytopathology\n100x oil immersion capability\nWide field number (FN 22 or greater)\nHigh-resolution visualization suitable for evaluation of cellular morphology, cytologic abnormalities, infectious organisms, and neoplastic processes\nOEM camera adapter compatibility for integration with existing digital imaging systems\nIllumination System:\nTrue Color LED light source compatible with BX43F, BX46F, and BX63F\nDaylight-balanced illumination to support accurate cytologic color interpretation\nFlicker-free, stable output\nLED lifespan 20,000 hours\nIntensity memory function\nUniform illumination across full field of view\nErgonomic and Mechanical Features:\nErgonomic observation tube with adjustable inclination\nLow-position coaxial focus knobs\nCoarse and fine focus with tension adjustment\nPrecision mechanical stage with fine movement control\nStage inserts compatible with cytology slide preparation\nConfiguration optimized for prolonged microscopic review\nRequired OEM Accessories and Components:\nThe Contractor shall provide all OEM components necessary to ensure full functionality and activation, including but not limited to:\nProprietary stage inserts\nLight modules\nCamera adapters\nImmersion oil kits (OEM approved)\nDust covers\nPower cords\nCalibration and setup materials\nRequired mounting hardware\nAny additional OEM components necessary for clinical operation\nAll components must be new, OEM-manufactured, and fully compatible with existing Evident BX-series microscopes currently deployed within the laboratory.\nInteroperability Requirements:\nThe Cytology Section is standardized on the Evident BX-series microscope platform. All diagnostic workflows, imaging protocols, training materials, and maintenance programs are built upon this system.\nThe requested microscopes are additional to the currently deployed fleet and must:\nIntegrate seamlessly with existing BX-series equipment\nMaintain optical consistency across the microscope fleet\nPreserve manufacturer warranty protections\nSupport existing service contracts and maintenance protocols\nRequire no retraining due to platform change\nNon-OEM or alternate-brand equipment would:\nDisrupt standardized diagnostic workflow\nIntroduce optical variability affecting diagnostic consistency\nInvalidate manufacturer warranties\nRequire retraining of cytotechnologists and pathologists\nUndermine fleet uniformity and serviceability\n\nWarranty:\nEquipment shall include the manufacturer s standard warranty covering optical, mechanical, and illumination systems for a minimum of one (1) year.\n3. BACKGROUND\nThe Department of Veterans Affairs Northeast Ohio Healthcare System (VANEOHS) has an immediate requirement for the procurement of two (2) brand name Evident (formerly Olympus) BX43-1-3 cytology microscopes, inclusive of the True Color LED light source compatible with BX43F, BX46F, and BX63F platforms, and all required Original Equipment Manufacturer (OEM) components and accessories necessary for full clinical activation and use.\n\nThe requested microscopes are additional units to the currently deployed Evident BX-series microscopes within the Cytology Section of Pathology & Laboratory Management Services (PALMS). The laboratory s diagnostic workflows, digital imaging systems, standardized operating procedures, educational protocols, and preventative maintenance programs are fully based upon the Evident BX-series platform.\nThe Cytology laboratory s diagnostic workflows, digital imaging systems, standardized operating procedures, educational platforms, and preventative maintenance programs are built upon the BX-series architecture.\nThe Cytology Section performs high-resolution visualization and evaluation of:\nCellular morphology\nCytological abnormalities\nMicrobiological organisms\nInflammatory processes\nNeoplastic pathologies\nThese diagnostic evaluations are mission-critical to accurate, timely, and actionable patient diagnoses.\nThis acquisition is required to maintain full operational capacity, mitigate diagnostic backlog, maximize utilization of existing Government-owned assets, and ensure uninterrupted cytopathology services.\n4. SCOPE\nThe Contractor shall provide two (2) new, current production BX43-1-3 microscopes, inclusive of the True Color LED light source and all requested and associated OEM components, accessories, modules, assemblies, and consumables required for immediate clinical deployment within the Cytology Section. The Contractor shall provide on-site installation, configuration, and operational verification of all microscopes and associated OEM components at the Louis Stokes Cleveland VA Medical Center, Pathology & Laboratory Management Services Cytology Section. Installation shall include full assembly, alignment of optical components, calibration of the illumination system, verification of mechanical stage functionality, confirmation of imaging integration (if applicable), and validation of overall system performance for clinical diagnostic use. All equipment shall be fully operational and ready for immediate patient care application upon completion of installation. Any deficiencies identified during installation or inspection shall be corrected by the Contractor at no additional cost to the Government prior to final acceptance.\n\nThe microscopes and components shall meet or exceed the following operational, optical, interoperability, and performance requirements:\nIf you are interested and can provide the sought-out supplies/services, please provide the requested information indicated below. Response to this notice should include company name, address, point of contact, DUNS number, and size of business pursuant to the following questions:\nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)\n\nIs your company considered small under the NAICS code identified under this RFI? If not, is your company considered small under a related NAICS code?\n\nAre you the manufacturer or distributor of the items being referenced above (or equivalent product/solution)? What is the manufacturing country of origin of these items?\n\nIf you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).\n\nIf you re a small business and you are an authorized distributor/reseller for the items identified above (or an equivalent solution), do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\n\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number.\n\nIf you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions you are providing information for available on your schedule/contract?\n\nPlease provide general pricing of your products/solution for market research purposes.\n\nPlease submit your capabilities in regard to the salient characteristics being provided and any information pertaining to brand name or equal to items to establish capabilities for planning purposes.\nNo re-manufactures or gray market items will be acceptable. Vendor shall be an Original Equipment Manufacturer (OEM), authorized dealer, authorized distributor or authorized reseller verified by an authorization letter or other documents from the OEM.\nSUBMISSION\nResponses to this notice shall be submitted via email to kevin.peeples@va.gov. Telephone responses shall not be accepted. Responses must be received no later than August 20, 2026, at 4:00pm EST, (Eastern Standard Time). If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this request for information. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation.","html":"SOURCES SOUGHT NOTICE\n\nTHIS REQUEST FOR INFORMATION (RFI/Sources Sought) IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 10.002(b)(2), FAR 12.101, FAR 12.103 & FAR 12.202(a).\nDISCLAIMER\nThis request for information, sources sought (RFI/Sources Sought) is issued solely for information and planning purposes only and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  IAW FAR 10.002(b)(2), FAR 12.101, FAR 12.103 & FAR 12.202(a), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\nThis is NOT a solicitation announcement.  This is a sources sought/RFI only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified Small Businesses under NAICS 339112, (Surgical and Medical Instrument Manufacturing industry), but does not exclude others from responding. Responses to this source sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this source sought, a solicitation announcement may be published.  Responses to this source sought synopsis are not considered adequate responses for a solicitation announcement.  \n\nSOURCES SOUGHT DESCRIPTION\nThe Department of Veterans Affairs, Network Contracting Office 10, Louis Stokes Cleveland VA Medical Center, is seeking sources that can provide a  BX43 Cytology Microscope and accessories  for Surgical Department Mechanical Room that meets the following: \n\nProduct/Items\nITEM NO.             DESCRIPTION                                   QUANTITY UNIT\nOR STOCK NO.                                                        \n             \n             Request purchase only of BX43 Pathology Microscope and accessories\n\nBX43-1-3 Microscope frame     2    EA\n   2. True color LED light source for BX43F, BX46F and BX63F                                                                                                      2    EA\n   3. UYCP-11; US Style 3-prong cord               2     EA\n   4. U-TTR-2 tiltable trinocular ergo                                     2     EA\n                         5. WHN10X-H-1-8 eyepiece NOSEPIECE,REVERSE,ANALYZER SLOT,RMS THREAD                                                                                              4     EA\n                         6. U-D6RE;6 POSITION                                                                  2     EA\n                         7. PLN2X/0,06 Plan Achromat, WD=5,8, NA=0,06 CC=-              2     EA\n                          8. PLN4X/0.1 Plan Achromat Objective 4x                                    2     EA\n                          9. PLN10X/0,25 Plan Achromat 10x,                                              2     EA\n                          10. PLN20X/0.4 Plan Achromat Objective 10 PLN20X/0.4 Plan Achromat Objective 20x                                                                                                             2    EA\n                           11. PLN40X/0,65 Plan Achromat 40x, WD=0,6, NA=0,65, CC=0,17\n                                                                                                                                    2   EA\n                           12. PLCN60X-1-7 Plan achromat objective\n             60X/0.8, WD 0.2                                                                                           2   EA\n                           13. Swing-out condenser, NA 0.9-0.17, with white contrast cap   2   EA\n                           14 U-SVRB-4; RIGHT HAND MECHANICAL STAGE, RACKLESS, LONG STALK                                                                                                           2   EA\n                          15. U-HLDT-4; LEFT RELEASE SLIDE HOLDER, DOUBLE SLIDE, THICK                                                                                                                       2   EA\n                          16. E9703006; DP23 1/1.8\" 6.4MP color CMOS, 2.4um, 45fps, incl. USB3.1 cable (2.9m)                                                                                                               2  EA\n                          17. cellSens Entry Electronic License                                             2   EA\n                          18 U-TV0.5XC-3-8 C-mount camera adapter                                 2   EA\n                          19. U-ANT; ANALYZER FOR TRANSMITTED                         2   EA\n             LIGHT, FITS IN NOSEPI SLIDER\n                 20. Polarizer For Transmitted Light, 45mm Diameter, Fits in BX Light Well\n                                                                                                                               2   EA\n                  21 COVER-018; DUST COVER, HOOD TYPE FOR BX2 MICROSCOPES\n                                                                                                                               2   EA\n                  22. SHIPPING AND HANDLING CHARGE                                    1 EA\n                  23. INCLUDES ON-SITE INSTALLATION, TRAINING & CALIBRATION\n                                                                                                                                1   EA\n\nOptical and Imaging Performance:\nUIS2 infinity-corrected optical system\nPlan Apochromat or Plan Fluorite objectives optimized for cytology applications\nHigh numerical aperture objectives suitable for oil immersion cytopathology\n100x oil immersion capability\nWide field number (FN 22 or greater)\nHigh-resolution visualization suitable for evaluation of cellular morphology, cytologic abnormalities, infectious organisms, and neoplastic processes\nOEM camera adapter compatibility for integration with existing digital imaging systems\nIllumination System:\nTrue Color LED light source compatible with BX43F, BX46F, and BX63F\nDaylight-balanced illumination to support accurate cytologic color interpretation\nFlicker-free, stable output\nLED lifespan   20,000 hours\nIntensity memory function\nUniform illumination across full field of view\nErgonomic and Mechanical Features:\nErgonomic observation tube with adjustable inclination\nLow-position coaxial focus knobs\nCoarse and fine focus with tension adjustment\nPrecision mechanical stage with fine movement control\nStage inserts compatible with cytology slide preparation\nConfiguration optimized for prolonged microscopic review\n Required OEM Accessories and Components:\nThe Contractor shall provide all OEM components necessary to ensure full functionality and activation, including but not limited to:\nProprietary stage inserts\nLight modules\nCamera adapters\nImmersion oil kits (OEM approved)\nDust covers\nPower cords\nCalibration and setup materials\nRequired mounting hardware\nAny additional OEM components necessary for clinical operation\nAll components must be new, OEM-manufactured, and fully compatible with existing Evident BX-series microscopes currently deployed within the laboratory.\nInteroperability Requirements:\nThe Cytology Section is standardized on the Evident BX-series microscope platform. All diagnostic workflows, imaging protocols, training materials, and maintenance programs are built upon this system.\nThe requested microscopes are additional to the currently deployed fleet and must:\nIntegrate seamlessly with existing BX-series equipment\nMaintain optical consistency across the microscope fleet\nPreserve manufacturer warranty protections\nSupport existing service contracts and maintenance protocols\nRequire no retraining due to platform change\nNon-OEM or alternate-brand equipment would:\nDisrupt standardized diagnostic workflow\nIntroduce optical variability affecting diagnostic consistency\nInvalidate manufacturer warranties\nRequire retraining of cytotechnologists and pathologists\nUndermine fleet uniformity and serviceability\n\nWarranty:\nEquipment shall include the manufacturer s standard warranty covering optical, mechanical, and illumination systems for a minimum of one (1) year.\n3. BACKGROUND  \nThe Department of Veterans Affairs Northeast Ohio Healthcare System (VANEOHS) has an immediate requirement for the procurement of two (2) brand name Evident (formerly Olympus) BX43-1-3 cytology microscopes, inclusive of the True Color LED light source compatible with BX43F, BX46F, and BX63F platforms, and all required Original Equipment Manufacturer (OEM) components and accessories necessary for full clinical activation and use.\n\nThe requested microscopes are additional units to the currently deployed Evident BX-series microscopes within the Cytology Section of Pathology & Laboratory Management Services (PALMS). The laboratory s diagnostic workflows, digital imaging systems, standardized operating procedures, educational protocols, and preventative maintenance programs are fully based upon the Evident BX-series platform.\nThe Cytology laboratory s diagnostic workflows, digital imaging systems, standardized operating procedures, educational platforms, and preventative maintenance programs are built upon the BX-series architecture.\nThe Cytology Section performs high-resolution visualization and evaluation of:\nCellular morphology\nCytological abnormalities\nMicrobiological organisms\nInflammatory processes\nNeoplastic pathologies\nThese diagnostic evaluations are mission-critical to accurate, timely, and actionable patient diagnoses.\nThis acquisition is required to maintain full operational capacity, mitigate diagnostic backlog, maximize utilization of existing Government-owned assets, and ensure uninterrupted cytopathology services.\n4. SCOPE \nThe Contractor shall provide two (2) new, current production BX43-1-3 microscopes, inclusive of the True Color LED light source and all requested and associated OEM components, accessories, modules, assemblies, and consumables required for immediate clinical deployment within the Cytology Section. The Contractor shall provide on-site installation, configuration, and operational verification of all microscopes and associated OEM components at the Louis Stokes Cleveland VA Medical Center, Pathology & Laboratory Management Services   Cytology Section. Installation shall include full assembly, alignment of optical components, calibration of the illumination system, verification of mechanical stage functionality, confirmation of imaging integration (if applicable), and validation of overall system performance for clinical diagnostic use. All equipment shall be fully operational and ready for immediate patient care application upon completion of installation. Any deficiencies identified during installation or inspection shall be corrected by the Contractor at no additional cost to the Government prior to final acceptance.\n\nThe microscopes and components shall meet or exceed the following operational, optical, interoperability, and performance requirements:\n If you are interested and can provide the sought-out supplies/services, please provide the requested information indicated below. Response to this notice should include company name, address, point of contact, DUNS number, and size of business pursuant to the following questions:  \nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)\n\nIs your company considered small under the NAICS code identified under this RFI? If not, is your company considered small under a related NAICS code?\n\nAre you the manufacturer or distributor of the items being referenced above (or equivalent product/solution)? What is the manufacturing country of origin of these items?\n\nIf you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).\n\nIf you re a small business and you are an authorized distributor/reseller for the items identified above (or an equivalent solution), do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\n\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number.\n\nIf you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions you are providing information for available on your schedule/contract?\n\nPlease provide general pricing of your products/solution for market research purposes.\n\nPlease submit your capabilities in regard to the salient characteristics being provided and any information pertaining to  brand name or equal to  items to establish capabilities for planning purposes.  \nNo re-manufactures or gray market items will be acceptable. Vendor shall be an Original Equipment Manufacturer (OEM), authorized dealer, authorized distributor or authorized reseller verified by an authorization letter or other documents from the OEM.\nSUBMISSION\nResponses to this notice shall be submitted via email to kevin.peeples@va.gov. Telephone responses shall not be accepted.  Responses must be received no later than August 20, 2026, at 4:00pm EST, (Eastern Standard Time). If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this request for information.  Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation.","origin":"detail"},"contacts":[{"fax":"NA","name":"KEVIN PEEPLES","role":"primary","email":"Kevin.peeples@va.gov","phone":"216-416-1600","title":"CONTRACT SPECIALIST"}],"place_of_performance":{"zip":"44106","city":{"name":"CLEVELAND"},"state":{"code":"OH"},"street":"VAMC CLEVELAND 10701 EAST BLVD.","country":{"code":"USA"}},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"naics_codes":["339112"],"award":null,"attachments":[{"resource_id":"ce474008e7714b7894ce2d9341ed31dc","name":"36C25026Q0896.docx","kind":"file","mime_type":".docx","size_bytes":26122,"posted_at":"2026-08-18T09:38:45.598Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/ce474008e7714b7894ce2d9341ed31dc/download","mirrored":false}],"awards":[],"related":[{"key":"36C25027Q0014","latest_notice_id":"b13cc87179e947e7b42da2de44a6bde1","title":"J061--541 Electrical Power Distribution Equipment Testing, Inspection, and Maintenance - VAMC Cleveland","solicitation_number":"36C25027Q0014","notice_type":"k","first_type":"k","first_posted":"2026-10-09","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"238210","psc":"J061","set_aside":"SBA","state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C25027Q0123","latest_notice_id":"fb53a332644a4c8fa983bf28c8643d2d","title":"S222--Sources Sought - Hazardous Waste Removal/Disposal Northeast Ohio VA Healthcare System - Cleveland, OH","solicitation_number":"36C25027Q0123","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T18:30:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"562112","psc":"S222","set_aside":null,"state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C25027B0009","latest_notice_id":"85b83d408f1f422885991142c2734b45","title":"Z1DA--FY27 NRM - VISN Base Modernize Nurse Call - 539-23-101","solicitation_number":"36C25027B0009","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"},{"key":"36C25027B0008","latest_notice_id":"5afe716a38494a6f84b1e84205805f86","title":"Z1DA--FY27 NRM - VISN Base Install Roof Equipment Railings - 539-22-206","solicitation_number":"36C25027B0008","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"},{"key":"36C25027B0005","latest_notice_id":"2cb4a6354be04cc89c5d6125945b1892","title":"Z1DA--***FY27 Requirement*** First Floor X Ray - Room CC157 553-CSI-022","solicitation_number":"36C25027B0005","notice_type":"p","first_type":"p","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"MI","county":"26163","county_name":"Wayne County","city":"2622000","city_name":"Detroit","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"}],"similar_open":[{"key":"W911S227U0200","latest_notice_id":"153aef7d00e740188276deb8422a2297","title":"Automated External Defibrillator (AED)","solicitation_number":"W911S227U0200","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T20:15:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:15:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24727Q0119","latest_notice_id":"81776fecabf149c9867d6253acdc2478","title":"Vivarium Tunnel Washer","solicitation_number":"36C24727Q0119","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"339112","psc":"6640","set_aside":null,"state":"GA","county":"13089","county_name":"DeKalb County","city":"1322052","city_name":"Decatur","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C10X27Q0025","latest_notice_id":"8c404062fbbc4212bb93120ad204ee50","title":"6515--NX EQ Microscope, Light, Operating, Hand/Plastic Surgery (VA-27-00017958)","solicitation_number":"36C10X27Q0025","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"}],"similar_open_total":15,"indexable":false}