{"canonical":"https://sealedbidder.com/opportunities/36c25026q0863","key":"36C25026Q0863","url":"https://sealedbidder.com/opportunities/36c25026q0863","title":"R425--Lock Out Tag Out (LOTO) Chillicothe VAMC","solicitation_number":"36C25026Q0863","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-08-18T19:00:00Z","first_posted":"2026-08-11","last_posted":"2026-08-11","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"541690","psc":"R425","set_aside":null,"place_state":"OH","place_scope":"site","site":"Chillicothe VA Medical Center","place_state_source":null,"place_evidence":null,"place_county":"39141","place_county_name":"Ross County","place_city":"3914184","place_city_name":"Chillicothe","winner":null,"award_amount":null,"publications":[{"notice_id":"56e47bd20fa3409a94f753ab1857b4b5","title":"R425--Lock Out Tag Out (LOTO) Chillicothe VAMC","solicitation_number":"36C25026Q0863","notice_type":"r","base_type":"r","posted":"2026-08-11","posted_at":"2026-08-11T17:14:23.241Z","due_at":"2026-08-18T19:00:00Z","due_date":"2026-08-18","cancelled":false,"archived":true,"archive_date":"2026-10-17","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/56e47bd20fa3409a94f753ab1857b4b5/view","enriched":true,"history":[{"index":1,"title":"R425--Lock Out Tag Out (LOTO) Chillicothe VAMC","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-11T17:14:23.241Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"56e47bd20fa3409a94f753ab1857b4b5","solicitation_number":"36C25026Q0863"}]}],"latest_notice_id":"56e47bd20fa3409a94f753ab1857b4b5","first_type":"r","notices":[{"dates":{"posted":"2026-08-11","posted_at":"2026-08-11T17:14:23.241Z","created_at":"2026-08-11T17:14:20.978Z","modified_at":"2026-08-11T17:14:23.241Z","response_deadline":{"raw":"2026-08-18T15:00:00-04:00","utc":"2026-08-18T19:00:00Z","date":"2026-08-18","time":"15:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/56e47bd20fa3409a94f753ab1857b4b5/view"},"naics":{"codes":["541690"],"primary":"541690"},"title":"R425--Lock Out Tag Out (LOTO) Chillicothe VAMC","agency":{"office":{"code":"36C250","name":"250-NETWORK CONTRACT OFFICE 10 (36C250)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"publication":"published","archive_date":"2026-10-17","archive_type":"auto_custom"},"history":[{"index":1,"title":"R425--Lock Out Tag Out (LOTO) Chillicothe VAMC","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-11T17:14:23.241Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"56e47bd20fa3409a94f753ab1857b4b5","solicitation_number":"36C25026Q0863"}],"contacts":[{"name":"Lakeisha Jackson","role":"primary","email":"Lakeisha.Jackson@va.gov","phone":"(216) 447-8300 ext. 49622","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"56e47bd20fa3409a94f753ab1857b4b5","lineage_id":"56e47bd20fa3409a94f753ab1857b4b5","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-19T00:57:29.923294823Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"8658895c13fa567ce5ddb63ea46d1abd49f5a5b2b2e42c2d21bb6d746df127d4","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-09-16T00:55:28.845070Z"},"description":{"html":"This is a Sources Sought (SS) Notice only, not a solicitation announcement and should not be considered as such. There is no solicitation available at this time. The Government will not pay for any information received in response to this SS, nor will the Government compensate any respondent for any cost incurred in developing the information provided to the Government. This SS does not constitute a commitment by the Government. Any information provided in response to this market survey will be used for informational purposes only and will not be released. Vendor participation is not a promise of future business with the Government.\nThe purpose of this Sources Sought is to conduct Market Research to determine an acquisition strategy for the acquisition of Lock Out   Tag Out (LOTO) services, o ensure machines, equipment, and related components are properly stopped, isolated from hazardous energy, and locked out before maintenance or servicing to prevent unexpected energization or start-up, in accordance with ANSI and OSHA requirements.\nThe NAICS code for this procurement is 541690 Other Scientific and Technical Consulting Services, JSC - R425 Support: Professional: Engineering/Technical and the small business size standard is $19,000,000.00.\n\nResponses to this notice shall be e-mailed to Lakrisha Jackson at Lakeisha.Jackson@va.gov. Telephone responses will not be accepted. Responses must be received in writing no later than  Tuesday, July 18, 2026 at 3:00 p.m. This notice is to assist the VA in determining sources only. A solicitation is not currently available.\n\nTHE VA IS NOT SEEKING PRICING OR OFFERS OF ANY KIND. There is no guarantee, expressed or implicit, that the market research for this acquisition will result in a particular set-aside or sole source award, or any other guarantee of award strategy. All information is to be provided on a voluntary basis at no charge to the Government.\n\nThe Chillicothe Veterans Affairs Medical Center, in Chillicothe, OH is seeking sources capable of complete the services described in the Performance Work Statement below: \n\n\n\n\n\n\n\n\n\nPerformance Work Statement\nTitle: Lock Out   Tag Out (LOTO)\nDate: As of 6-16-2026\n\nBackground:\nThe Chillicothe VAMC requires performance-based services to ensure machines, equipment, and related components are properly stopped, isolated from hazardous energy, and locked out before maintenance or servicing to prevent unexpected energization or start-up, in accordance with ANSI and OSHA requirements.\nPlace of Performance: \n\nChillicothe, Ohio Veterans Affairs Medical Center (VAMC) 17273 State Route 104, Chillicothe, OH 45601.\n\nPeriod of Performance:\n\nBase Year:Â Date of award through one year\nOption Years:Â Four (4) one-year option periods, for a total potential period of five (5) years\n\nScope of Work: \n\nThe Contractor shall provide all labor, materials, supervision, equipment, and services necessary to develop, implement, and annually review graphical Lock Out Tag Out (LOTO) procedures for all identified equipment at the Chillicothe VAMC. Work includes creating graphical LOTO procedures to ensure the machines, equipment, and other components and systems is stopped, isolated from all potentially hazardous energy sources, and locked out before employees perform any servicing or maintenance where the unexpected energization or start-up of the machine or equipment or release stored energy, developing and affixing placards, providing digital and hard copy documentation, labeling assets, training VA employees, and evaluating additional equipment annually as required.\n\nConformance Standards: \n\nAll work shall meet or exceed the following standards:\nOSHA 29 CFR 1910.147   Control of Hazardous Energy\nOSHA 29 CFR 1910.301-399, Subpart S   Electrical\nANSI standards as applicable\nVA policies and procedures as provided in contract documents\n\nQualifications of Contractors:\n\nContractors must demonstrate documented experience with electrical safety programs and implementation of OSHA/ANSI LOTO programs in healthcare or similar environments.\n\nCodes and Standards:\n\n29 CFR 1910.147: Control of Hazardous Energy (LOTO)\n29 CFR 1910.301-399, Subpart S: Electrical Standards\nANSI Z244.1   Control of Hazardous Energy\nAll applicable VA policies and regulatory guidance\n\nSpecific Tasks and Deliverables: \n\nDevelop Graphical LOTO Procedures:\nCreate a minimum of 454 equipment-specific, graphical procedures.\nEach procedure shall incorporate direct collaboration with assigned VA electricians for field verification; reliance on drawings alone is not allowed.\nWhere shutdowns are not possible, contractors and VA personnel will create procedures that ensure safe, effective verification of energy isolation.\nProvide and Affix Placards:\nProvide durable, laminated placards for each asset.\nPlacards must be attached to the equipment and clearly display the correct LOTO procedure.\nCreate Documentation Binders:\nTwo tabbed and indexed binders listing all covered equipment, locations, and associated procedures.\nDeliver digital and hard copy files to COR.\nAsset Labeling:\nInclude asset number labels on all covered equipment.\nAnnual Review & Additional Assets:\nPerform annual review; update LOTO program as equipment inventory changes.\nFirst year to cover base list of 137 items from VA Chillicothe Engineering and remaining years to review existing LOTO procedures and make 20 or less asset additions to the LOTO program for any equipment not covered.  Assets to be included in option years will be provided prior to coordinated visits\nTraining:\nTrain an unlimited number of VA staff in both LOTO regulations and facility-specific LOTO procedures.\nInclude hands-on demonstration, ESC and Rockwell tool instruction (Excel-based templates for program customization).\nCollaboration and Scheduling:\nCoordinate with VA Facilities and Engineering to minimize operational disruption.\nProvide service with minimal/no operational downtime. When equipment cannot be shut down, collaborative hazard analysis with VA electricians is required.\n\n\n\nCovered  Equipment: \n\nAll machinery and equipment designated by Chillicothe VAMC Engineering, initially identified as 137 assets and increasing up to 454 during the contract period. Asset lists will be updated at each annual review. A complete inventory will be provided to the Contractor at project initiation and annually thereafter.\n\nHours of Operation: \n\nScheduled service will be performed during normal business hours which considered to be Monday-Friday 7:30am to 4:00pm, (excluding the Federal Holidays of New Year s Day; Martin Luther King Day; President s Day; Memorial Day; Independence Day; Labor Day; Columbus Day; Veteran s Day; Thanksgiving Day; Christmas Day; and any other declared Federal Holiday by the President of the United States).\n\nReporting Requirements: \nThe Contractor shall be required to schedule an appropriate service date with Facilities Management for the equipment to be taken out of service with little or no disruption to the normal operation of the VA Medical Center.  The Contracting Officer Representative (COR) shall have the final approval of the time for the Emergent Maintenance.\n\nContractors shall check in with the Engineering Department currently located on the NE side of Building 21.  Scheduled service will be performed during normal business hours which considered to be Monday-Friday 7:30am to 4:00pm, (excluding the Federal Holidays of New Year s Day; Martin Luther King Day; President s Day; Memorial Day; Independence Day; Labor Day; Columbus Day; Veteran s Day; Thanksgiving Day; Christmas Day; and any other declared Federal Holiday by the President of the United States).  \n\nChecking in is mandatory. When the service is complete, the Contractor shall document services rendered on a legible field service report. The Contractor shall log out at the Facilities Management Office and submit the field service report to the Contracting Officer Representative (COR) for a signature, during normal working hours. \n\nIf this work is to be performed after normal work hours, then check-in will occur with the Utility Systems Employee on Duty, at the Energy Center, Building 261.  This area is staffed 24 hours/day and 7 days a week\n\nSafety Requirements: \n\nIn the performance of this contract, the Contractor shall take such safety precautions as OSHA may determine to be reasonably necessary to protect the lives and health of occupants of the building. The Contracting Officer shall notify the Contractor of any safety issues and the action necessary to correct these issues. Such notice, when served on the Contractor or his representative at the work site shall be deemed sufficient for the corrective actions to be taken. If the Contractor fails or refuses to comply promptly, the Contracting Officer may issue an order stopping all or part of the work and hold the Contractor in default.\n\nGeneral Security:\nContractors, contractor personnel, subcontractors, and subcontractor personnel shall be subject to the same Federal laws, regulations, standards, and VA Directives and Handbooks as VA and VA personnel regarding information and information system security.\n\nContractor is also responsible for checking in with the Engineering Department northeast side of building 21. The contractor will sign out a temporary badge for all contractor/subcontractor personnel.  Every worker must have a badge and form of identification when working on VA property and is subject to VA security checks and enforcement actions while working on VA property.\n\nRisk Control:\n\nWork performed within the Chillicothe VAMC may present health risks including exposure to illness and infection control. Contractor will take action to recognize and follow warning information throughout the facility.\n\n\n\nPerformance Requirements Summary:\n\n\nPWS Task\nPerformance Standard\nAcceptable Quality Level (AQL)\nSurveillance Method\nIncentive\n Rating \n(Met/Not Met AQL)\nDevelop graphical LOTO procedures for all identified assets\n100% completion by end of the contract\n90% Compliance\nInspection and review of contractor records quarterly\nSatisfactory performance results in positive CPARS review\nMet / Not Met\nSubmit LOTO procedure documentation to COR\nProcedures submitted within 30 business days of completion\n90% Compliance\nReview of records and submission dates\nContinued eligibility for future contracts, positive past performance\nMet / Not Met\nAddress identified deficiencies in procedures\nCorrection within 10 business days of notification\n\n100% \nCompliance\nReview of records, inspection follow-up\nNone; Noncompliance may result in a Contract Discrepancy Report (CDR)\nMet / Not Met\nAttach placards to the equipment\n100% completion by end of the contract\n90% Compliance\nDirect observation\nSatisfactory performance results in positive CPARS review\nMet / Not Met\n\n\n\nQuality Control Program Requirement    \nGeneral Requirements: The contractor shall establish, implement and maintain a comprehensive Quality Control Program (QCP) to ensure all services are performed in accordance with the Performance Work Statement and the metrics outlined in the Performance Requirements Summary. \nSubmissions and Updates: The contractor shall submit a detailed written Quality Control Plan the Contracting Officer (CO) and the Contracting Officer s Representative  for review and approval within 14 calendar says of contractor award. Contractor shall update the plan annually or within 7 calendar days of any significant changes to the internal process.\nInspection System: The QCP must detail the Contractors internal inspection mechanics, covering all tasks and deliverables. The plan must specify the metrics tracked, the frequency of internal audits, and identify by name or role the specific personnel responsible for conducting the inspections.\nDeficiency Resolution:  The QCP must include a clear methodology for identifying, tracking and correcting deficiencies in service quality. It must prevent the recurrence of defective work without relying on government intervention. \nRecord Keeping and Audits: The contractor shall maintain records of all internal inspections, including corrective actions taken. These records shall be made available to the government upon request at any point during contract performance. T\nNOTE: The QCP shall be in compliance with the following OSHA standards:\nCode of Federal Regulations, Title 29, part 1910.147,  The Control of Hazardous Energy (Lockout and Tagout) \nCode of Federal Regulations, Title 29, part 1910.301-399, Subpart S,  Electrical \nOSHA Letters of Interpretation","text":"This is a Sources Sought (SS) Notice only, not a solicitation announcement and should not be considered as such. There is no solicitation available at this time. The Government will not pay for any information received in response to this SS, nor will the Government compensate any respondent for any cost incurred in developing the information provided to the Government. This SS does not constitute a commitment by the Government. Any information provided in response to this market survey will be used for informational purposes only and will not be released. Vendor participation is not a promise of future business with the Government.\nThe purpose of this Sources Sought is to conduct Market Research to determine an acquisition strategy for the acquisition of Lock Out Tag Out (LOTO) services, o ensure machines, equipment, and related components are properly stopped, isolated from hazardous energy, and locked out before maintenance or servicing to prevent unexpected energization or start-up, in accordance with ANSI and OSHA requirements.\nThe NAICS code for this procurement is 541690 Other Scientific and Technical Consulting Services, JSC - R425 Support: Professional: Engineering/Technical and the small business size standard is $19,000,000.00.\n\nResponses to this notice shall be e-mailed to Lakrisha Jackson at Lakeisha.Jackson@va.gov. Telephone responses will not be accepted. Responses must be received in writing no later than Tuesday, July 18, 2026 at 3:00 p.m. This notice is to assist the VA in determining sources only. A solicitation is not currently available.\n\nTHE VA IS NOT SEEKING PRICING OR OFFERS OF ANY KIND. There is no guarantee, expressed or implicit, that the market research for this acquisition will result in a particular set-aside or sole source award, or any other guarantee of award strategy. All information is to be provided on a voluntary basis at no charge to the Government.\n\nThe Chillicothe Veterans Affairs Medical Center, in Chillicothe, OH is seeking sources capable of complete the services described in the Performance Work Statement below:\n\nPerformance Work Statement\nTitle: Lock Out Tag Out (LOTO)\nDate: As of 6-16-2026\n\nBackground:\nThe Chillicothe VAMC requires performance-based services to ensure machines, equipment, and related components are properly stopped, isolated from hazardous energy, and locked out before maintenance or servicing to prevent unexpected energization or start-up, in accordance with ANSI and OSHA requirements.\nPlace of Performance:\n\nChillicothe, Ohio Veterans Affairs Medical Center (VAMC) 17273 State Route 104, Chillicothe, OH 45601.\n\nPeriod of Performance:\n\nBase Year:Â Date of award through one year\nOption Years:Â Four (4) one-year option periods, for a total potential period of five (5) years\n\nScope of Work:\n\nThe Contractor shall provide all labor, materials, supervision, equipment, and services necessary to develop, implement, and annually review graphical Lock Out Tag Out (LOTO) procedures for all identified equipment at the Chillicothe VAMC. Work includes creating graphical LOTO procedures to ensure the machines, equipment, and other components and systems is stopped, isolated from all potentially hazardous energy sources, and locked out before employees perform any servicing or maintenance where the unexpected energization or start-up of the machine or equipment or release stored energy, developing and affixing placards, providing digital and hard copy documentation, labeling assets, training VA employees, and evaluating additional equipment annually as required.\n\nConformance Standards:\n\nAll work shall meet or exceed the following standards:\nOSHA 29 CFR 1910.147 Control of Hazardous Energy\nOSHA 29 CFR 1910.301-399, Subpart S Electrical\nANSI standards as applicable\nVA policies and procedures as provided in contract documents\n\nQualifications of Contractors:\n\nContractors must demonstrate documented experience with electrical safety programs and implementation of OSHA/ANSI LOTO programs in healthcare or similar environments.\n\nCodes and Standards:\n\n29 CFR 1910.147: Control of Hazardous Energy (LOTO)\n29 CFR 1910.301-399, Subpart S: Electrical Standards\nANSI Z244.1 Control of Hazardous Energy\nAll applicable VA policies and regulatory guidance\n\nSpecific Tasks and Deliverables:\n\nDevelop Graphical LOTO Procedures:\nCreate a minimum of 454 equipment-specific, graphical procedures.\nEach procedure shall incorporate direct collaboration with assigned VA electricians for field verification; reliance on drawings alone is not allowed.\nWhere shutdowns are not possible, contractors and VA personnel will create procedures that ensure safe, effective verification of energy isolation.\nProvide and Affix Placards:\nProvide durable, laminated placards for each asset.\nPlacards must be attached to the equipment and clearly display the correct LOTO procedure.\nCreate Documentation Binders:\nTwo tabbed and indexed binders listing all covered equipment, locations, and associated procedures.\nDeliver digital and hard copy files to COR.\nAsset Labeling:\nInclude asset number labels on all covered equipment.\nAnnual Review & Additional Assets:\nPerform annual review; update LOTO program as equipment inventory changes.\nFirst year to cover base list of 137 items from VA Chillicothe Engineering and remaining years to review existing LOTO procedures and make 20 or less asset additions to the LOTO program for any equipment not covered. Assets to be included in option years will be provided prior to coordinated visits\nTraining:\nTrain an unlimited number of VA staff in both LOTO regulations and facility-specific LOTO procedures.\nInclude hands-on demonstration, ESC and Rockwell tool instruction (Excel-based templates for program customization).\nCollaboration and Scheduling:\nCoordinate with VA Facilities and Engineering to minimize operational disruption.\nProvide service with minimal/no operational downtime. When equipment cannot be shut down, collaborative hazard analysis with VA electricians is required.\n\nCovered Equipment:\n\nAll machinery and equipment designated by Chillicothe VAMC Engineering, initially identified as 137 assets and increasing up to 454 during the contract period. Asset lists will be updated at each annual review. A complete inventory will be provided to the Contractor at project initiation and annually thereafter.\n\nHours of Operation:\n\nScheduled service will be performed during normal business hours which considered to be Monday-Friday 7:30am to 4:00pm, (excluding the Federal Holidays of New Year s Day; Martin Luther King Day; President s Day; Memorial Day; Independence Day; Labor Day; Columbus Day; Veteran s Day; Thanksgiving Day; Christmas Day; and any other declared Federal Holiday by the President of the United States).\n\nReporting Requirements:\nThe Contractor shall be required to schedule an appropriate service date with Facilities Management for the equipment to be taken out of service with little or no disruption to the normal operation of the VA Medical Center. The Contracting Officer Representative (COR) shall have the final approval of the time for the Emergent Maintenance.\n\nContractors shall check in with the Engineering Department currently located on the NE side of Building 21. Scheduled service will be performed during normal business hours which considered to be Monday-Friday 7:30am to 4:00pm, (excluding the Federal Holidays of New Year s Day; Martin Luther King Day; President s Day; Memorial Day; Independence Day; Labor Day; Columbus Day; Veteran s Day; Thanksgiving Day; Christmas Day; and any other declared Federal Holiday by the President of the United States).\n\nChecking in is mandatory. When the service is complete, the Contractor shall document services rendered on a legible field service report. The Contractor shall log out at the Facilities Management Office and submit the field service report to the Contracting Officer Representative (COR) for a signature, during normal working hours.\n\nIf this work is to be performed after normal work hours, then check-in will occur with the Utility Systems Employee on Duty, at the Energy Center, Building 261. This area is staffed 24 hours/day and 7 days a week\n\nSafety Requirements:\n\nIn the performance of this contract, the Contractor shall take such safety precautions as OSHA may determine to be reasonably necessary to protect the lives and health of occupants of the building. The Contracting Officer shall notify the Contractor of any safety issues and the action necessary to correct these issues. Such notice, when served on the Contractor or his representative at the work site shall be deemed sufficient for the corrective actions to be taken. If the Contractor fails or refuses to comply promptly, the Contracting Officer may issue an order stopping all or part of the work and hold the Contractor in default.\n\nGeneral Security:\nContractors, contractor personnel, subcontractors, and subcontractor personnel shall be subject to the same Federal laws, regulations, standards, and VA Directives and Handbooks as VA and VA personnel regarding information and information system security.\n\nContractor is also responsible for checking in with the Engineering Department northeast side of building 21. The contractor will sign out a temporary badge for all contractor/subcontractor personnel. Every worker must have a badge and form of identification when working on VA property and is subject to VA security checks and enforcement actions while working on VA property.\n\nRisk Control:\n\nWork performed within the Chillicothe VAMC may present health risks including exposure to illness and infection control. Contractor will take action to recognize and follow warning information throughout the facility.\n\nPerformance Requirements Summary:\n\nPWS Task\nPerformance Standard\nAcceptable Quality Level (AQL)\nSurveillance Method\nIncentive\nRating\n(Met/Not Met AQL)\nDevelop graphical LOTO procedures for all identified assets\n100% completion by end of the contract\n90% Compliance\nInspection and review of contractor records quarterly\nSatisfactory performance results in positive CPARS review\nMet / Not Met\nSubmit LOTO procedure documentation to COR\nProcedures submitted within 30 business days of completion\n90% Compliance\nReview of records and submission dates\nContinued eligibility for future contracts, positive past performance\nMet / Not Met\nAddress identified deficiencies in procedures\nCorrection within 10 business days of notification\n\n100%\nCompliance\nReview of records, inspection follow-up\nNone; Noncompliance may result in a Contract Discrepancy Report (CDR)\nMet / Not Met\nAttach placards to the equipment\n100% completion by end of the contract\n90% Compliance\nDirect observation\nSatisfactory performance results in positive CPARS review\nMet / Not Met\n\nQuality Control Program Requirement\nGeneral Requirements: The contractor shall establish, implement and maintain a comprehensive Quality Control Program (QCP) to ensure all services are performed in accordance with the Performance Work Statement and the metrics outlined in the Performance Requirements Summary.\nSubmissions and Updates: The contractor shall submit a detailed written Quality Control Plan the Contracting Officer (CO) and the Contracting Officer s Representative for review and approval within 14 calendar says of contractor award. Contractor shall update the plan annually or within 7 calendar days of any significant changes to the internal process.\nInspection System: The QCP must detail the Contractors internal inspection mechanics, covering all tasks and deliverables. The plan must specify the metrics tracked, the frequency of internal audits, and identify by name or role the specific personnel responsible for conducting the inspections.\nDeficiency Resolution: The QCP must include a clear methodology for identifying, tracking and correcting deficiencies in service quality. It must prevent the recurrence of defective work without relying on government intervention.\nRecord Keeping and Audits: The contractor shall maintain records of all internal inspections, including corrective actions taken. These records shall be made available to the government upon request at any point during contract performance. T\nNOTE: The QCP shall be in compliance with the following OSHA standards:\nCode of Federal Regulations, Title 29, part 1910.147, The Control of Hazardous Energy (Lockout and Tagout)\nCode of Federal Regulations, Title 29, part 1910.301-399, Subpart S, Electrical\nOSHA Letters of Interpretation","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25026Q0863","place_of_performance":{"zip":"45601","city":{"name":"Chillicothe"},"state":{"code":"OH"},"street":"Chillicothe Veterans Affairs Medical Center 17273 State Route 104","country":{"code":"USA"}},"product_service_code":"R425"}],"due_at":"2026-08-18T19:00:00Z","due_date":"2026-08-18","closes_at":"2026-08-18T19:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","state":"OH","county":"39141","county_name":"Ross County","city":"3914184","city_name":"Chillicothe","country":"USA","state_source":null,"state_evidence":null,"site_key":"chillicothe-va-medical-center-oh","winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-18T04:56:43.547826Z","principal_notice_id":"56e47bd20fa3409a94f753ab1857b4b5","description":{"text":"This is a Sources Sought (SS) Notice only, not a solicitation announcement and should not be considered as such. There is no solicitation available at this time. The Government will not pay for any information received in response to this SS, nor will the Government compensate any respondent for any cost incurred in developing the information provided to the Government. This SS does not constitute a commitment by the Government. Any information provided in response to this market survey will be used for informational purposes only and will not be released. Vendor participation is not a promise of future business with the Government.\nThe purpose of this Sources Sought is to conduct Market Research to determine an acquisition strategy for the acquisition of Lock Out Tag Out (LOTO) services, o ensure machines, equipment, and related components are properly stopped, isolated from hazardous energy, and locked out before maintenance or servicing to prevent unexpected energization or start-up, in accordance with ANSI and OSHA requirements.\nThe NAICS code for this procurement is 541690 Other Scientific and Technical Consulting Services, JSC - R425 Support: Professional: Engineering/Technical and the small business size standard is $19,000,000.00.\n\nResponses to this notice shall be e-mailed to Lakrisha Jackson at Lakeisha.Jackson@va.gov. Telephone responses will not be accepted. Responses must be received in writing no later than Tuesday, July 18, 2026 at 3:00 p.m. This notice is to assist the VA in determining sources only. A solicitation is not currently available.\n\nTHE VA IS NOT SEEKING PRICING OR OFFERS OF ANY KIND. There is no guarantee, expressed or implicit, that the market research for this acquisition will result in a particular set-aside or sole source award, or any other guarantee of award strategy. All information is to be provided on a voluntary basis at no charge to the Government.\n\nThe Chillicothe Veterans Affairs Medical Center, in Chillicothe, OH is seeking sources capable of complete the services described in the Performance Work Statement below:\n\nPerformance Work Statement\nTitle: Lock Out Tag Out (LOTO)\nDate: As of 6-16-2026\n\nBackground:\nThe Chillicothe VAMC requires performance-based services to ensure machines, equipment, and related components are properly stopped, isolated from hazardous energy, and locked out before maintenance or servicing to prevent unexpected energization or start-up, in accordance with ANSI and OSHA requirements.\nPlace of Performance:\n\nChillicothe, Ohio Veterans Affairs Medical Center (VAMC) 17273 State Route 104, Chillicothe, OH 45601.\n\nPeriod of Performance:\n\nBase Year:Â Date of award through one year\nOption Years:Â Four (4) one-year option periods, for a total potential period of five (5) years\n\nScope of Work:\n\nThe Contractor shall provide all labor, materials, supervision, equipment, and services necessary to develop, implement, and annually review graphical Lock Out Tag Out (LOTO) procedures for all identified equipment at the Chillicothe VAMC. Work includes creating graphical LOTO procedures to ensure the machines, equipment, and other components and systems is stopped, isolated from all potentially hazardous energy sources, and locked out before employees perform any servicing or maintenance where the unexpected energization or start-up of the machine or equipment or release stored energy, developing and affixing placards, providing digital and hard copy documentation, labeling assets, training VA employees, and evaluating additional equipment annually as required.\n\nConformance Standards:\n\nAll work shall meet or exceed the following standards:\nOSHA 29 CFR 1910.147 Control of Hazardous Energy\nOSHA 29 CFR 1910.301-399, Subpart S Electrical\nANSI standards as applicable\nVA policies and procedures as provided in contract documents\n\nQualifications of Contractors:\n\nContractors must demonstrate documented experience with electrical safety programs and implementation of OSHA/ANSI LOTO programs in healthcare or similar environments.\n\nCodes and Standards:\n\n29 CFR 1910.147: Control of Hazardous Energy (LOTO)\n29 CFR 1910.301-399, Subpart S: Electrical Standards\nANSI Z244.1 Control of Hazardous Energy\nAll applicable VA policies and regulatory guidance\n\nSpecific Tasks and Deliverables:\n\nDevelop Graphical LOTO Procedures:\nCreate a minimum of 454 equipment-specific, graphical procedures.\nEach procedure shall incorporate direct collaboration with assigned VA electricians for field verification; reliance on drawings alone is not allowed.\nWhere shutdowns are not possible, contractors and VA personnel will create procedures that ensure safe, effective verification of energy isolation.\nProvide and Affix Placards:\nProvide durable, laminated placards for each asset.\nPlacards must be attached to the equipment and clearly display the correct LOTO procedure.\nCreate Documentation Binders:\nTwo tabbed and indexed binders listing all covered equipment, locations, and associated procedures.\nDeliver digital and hard copy files to COR.\nAsset Labeling:\nInclude asset number labels on all covered equipment.\nAnnual Review & Additional Assets:\nPerform annual review; update LOTO program as equipment inventory changes.\nFirst year to cover base list of 137 items from VA Chillicothe Engineering and remaining years to review existing LOTO procedures and make 20 or less asset additions to the LOTO program for any equipment not covered. Assets to be included in option years will be provided prior to coordinated visits\nTraining:\nTrain an unlimited number of VA staff in both LOTO regulations and facility-specific LOTO procedures.\nInclude hands-on demonstration, ESC and Rockwell tool instruction (Excel-based templates for program customization).\nCollaboration and Scheduling:\nCoordinate with VA Facilities and Engineering to minimize operational disruption.\nProvide service with minimal/no operational downtime. When equipment cannot be shut down, collaborative hazard analysis with VA electricians is required.\n\nCovered Equipment:\n\nAll machinery and equipment designated by Chillicothe VAMC Engineering, initially identified as 137 assets and increasing up to 454 during the contract period. Asset lists will be updated at each annual review. A complete inventory will be provided to the Contractor at project initiation and annually thereafter.\n\nHours of Operation:\n\nScheduled service will be performed during normal business hours which considered to be Monday-Friday 7:30am to 4:00pm, (excluding the Federal Holidays of New Year s Day; Martin Luther King Day; President s Day; Memorial Day; Independence Day; Labor Day; Columbus Day; Veteran s Day; Thanksgiving Day; Christmas Day; and any other declared Federal Holiday by the President of the United States).\n\nReporting Requirements:\nThe Contractor shall be required to schedule an appropriate service date with Facilities Management for the equipment to be taken out of service with little or no disruption to the normal operation of the VA Medical Center. The Contracting Officer Representative (COR) shall have the final approval of the time for the Emergent Maintenance.\n\nContractors shall check in with the Engineering Department currently located on the NE side of Building 21. Scheduled service will be performed during normal business hours which considered to be Monday-Friday 7:30am to 4:00pm, (excluding the Federal Holidays of New Year s Day; Martin Luther King Day; President s Day; Memorial Day; Independence Day; Labor Day; Columbus Day; Veteran s Day; Thanksgiving Day; Christmas Day; and any other declared Federal Holiday by the President of the United States).\n\nChecking in is mandatory. When the service is complete, the Contractor shall document services rendered on a legible field service report. The Contractor shall log out at the Facilities Management Office and submit the field service report to the Contracting Officer Representative (COR) for a signature, during normal working hours.\n\nIf this work is to be performed after normal work hours, then check-in will occur with the Utility Systems Employee on Duty, at the Energy Center, Building 261. This area is staffed 24 hours/day and 7 days a week\n\nSafety Requirements:\n\nIn the performance of this contract, the Contractor shall take such safety precautions as OSHA may determine to be reasonably necessary to protect the lives and health of occupants of the building. The Contracting Officer shall notify the Contractor of any safety issues and the action necessary to correct these issues. Such notice, when served on the Contractor or his representative at the work site shall be deemed sufficient for the corrective actions to be taken. If the Contractor fails or refuses to comply promptly, the Contracting Officer may issue an order stopping all or part of the work and hold the Contractor in default.\n\nGeneral Security:\nContractors, contractor personnel, subcontractors, and subcontractor personnel shall be subject to the same Federal laws, regulations, standards, and VA Directives and Handbooks as VA and VA personnel regarding information and information system security.\n\nContractor is also responsible for checking in with the Engineering Department northeast side of building 21. The contractor will sign out a temporary badge for all contractor/subcontractor personnel. Every worker must have a badge and form of identification when working on VA property and is subject to VA security checks and enforcement actions while working on VA property.\n\nRisk Control:\n\nWork performed within the Chillicothe VAMC may present health risks including exposure to illness and infection control. Contractor will take action to recognize and follow warning information throughout the facility.\n\nPerformance Requirements Summary:\n\nPWS Task\nPerformance Standard\nAcceptable Quality Level (AQL)\nSurveillance Method\nIncentive\nRating\n(Met/Not Met AQL)\nDevelop graphical LOTO procedures for all identified assets\n100% completion by end of the contract\n90% Compliance\nInspection and review of contractor records quarterly\nSatisfactory performance results in positive CPARS review\nMet / Not Met\nSubmit LOTO procedure documentation to COR\nProcedures submitted within 30 business days of completion\n90% Compliance\nReview of records and submission dates\nContinued eligibility for future contracts, positive past performance\nMet / Not Met\nAddress identified deficiencies in procedures\nCorrection within 10 business days of notification\n\n100%\nCompliance\nReview of records, inspection follow-up\nNone; Noncompliance may result in a Contract Discrepancy Report (CDR)\nMet / Not Met\nAttach placards to the equipment\n100% completion by end of the contract\n90% Compliance\nDirect observation\nSatisfactory performance results in positive CPARS review\nMet / Not Met\n\nQuality Control Program Requirement\nGeneral Requirements: The contractor shall establish, implement and maintain a comprehensive Quality Control Program (QCP) to ensure all services are performed in accordance with the Performance Work Statement and the metrics outlined in the Performance Requirements Summary.\nSubmissions and Updates: The contractor shall submit a detailed written Quality Control Plan the Contracting Officer (CO) and the Contracting Officer s Representative for review and approval within 14 calendar says of contractor award. Contractor shall update the plan annually or within 7 calendar days of any significant changes to the internal process.\nInspection System: The QCP must detail the Contractors internal inspection mechanics, covering all tasks and deliverables. The plan must specify the metrics tracked, the frequency of internal audits, and identify by name or role the specific personnel responsible for conducting the inspections.\nDeficiency Resolution: The QCP must include a clear methodology for identifying, tracking and correcting deficiencies in service quality. It must prevent the recurrence of defective work without relying on government intervention.\nRecord Keeping and Audits: The contractor shall maintain records of all internal inspections, including corrective actions taken. These records shall be made available to the government upon request at any point during contract performance. T\nNOTE: The QCP shall be in compliance with the following OSHA standards:\nCode of Federal Regulations, Title 29, part 1910.147, The Control of Hazardous Energy (Lockout and Tagout)\nCode of Federal Regulations, Title 29, part 1910.301-399, Subpart S, Electrical\nOSHA Letters of Interpretation","html":"This is a Sources Sought (SS) Notice only, not a solicitation announcement and should not be considered as such. There is no solicitation available at this time. The Government will not pay for any information received in response to this SS, nor will the Government compensate any respondent for any cost incurred in developing the information provided to the Government. This SS does not constitute a commitment by the Government. Any information provided in response to this market survey will be used for informational purposes only and will not be released. Vendor participation is not a promise of future business with the Government.\nThe purpose of this Sources Sought is to conduct Market Research to determine an acquisition strategy for the acquisition of Lock Out   Tag Out (LOTO) services, o ensure machines, equipment, and related components are properly stopped, isolated from hazardous energy, and locked out before maintenance or servicing to prevent unexpected energization or start-up, in accordance with ANSI and OSHA requirements.\nThe NAICS code for this procurement is 541690 Other Scientific and Technical Consulting Services, JSC - R425 Support: Professional: Engineering/Technical and the small business size standard is $19,000,000.00.\n\nResponses to this notice shall be e-mailed to Lakrisha Jackson at Lakeisha.Jackson@va.gov. Telephone responses will not be accepted. Responses must be received in writing no later than  Tuesday, July 18, 2026 at 3:00 p.m. This notice is to assist the VA in determining sources only. A solicitation is not currently available.\n\nTHE VA IS NOT SEEKING PRICING OR OFFERS OF ANY KIND. There is no guarantee, expressed or implicit, that the market research for this acquisition will result in a particular set-aside or sole source award, or any other guarantee of award strategy. All information is to be provided on a voluntary basis at no charge to the Government.\n\nThe Chillicothe Veterans Affairs Medical Center, in Chillicothe, OH is seeking sources capable of complete the services described in the Performance Work Statement below: \n\n\n\n\n\n\n\n\n\nPerformance Work Statement\nTitle: Lock Out   Tag Out (LOTO)\nDate: As of 6-16-2026\n\nBackground:\nThe Chillicothe VAMC requires performance-based services to ensure machines, equipment, and related components are properly stopped, isolated from hazardous energy, and locked out before maintenance or servicing to prevent unexpected energization or start-up, in accordance with ANSI and OSHA requirements.\nPlace of Performance: \n\nChillicothe, Ohio Veterans Affairs Medical Center (VAMC) 17273 State Route 104, Chillicothe, OH 45601.\n\nPeriod of Performance:\n\nBase Year:Â Date of award through one year\nOption Years:Â Four (4) one-year option periods, for a total potential period of five (5) years\n\nScope of Work: \n\nThe Contractor shall provide all labor, materials, supervision, equipment, and services necessary to develop, implement, and annually review graphical Lock Out Tag Out (LOTO) procedures for all identified equipment at the Chillicothe VAMC. Work includes creating graphical LOTO procedures to ensure the machines, equipment, and other components and systems is stopped, isolated from all potentially hazardous energy sources, and locked out before employees perform any servicing or maintenance where the unexpected energization or start-up of the machine or equipment or release stored energy, developing and affixing placards, providing digital and hard copy documentation, labeling assets, training VA employees, and evaluating additional equipment annually as required.\n\nConformance Standards: \n\nAll work shall meet or exceed the following standards:\nOSHA 29 CFR 1910.147   Control of Hazardous Energy\nOSHA 29 CFR 1910.301-399, Subpart S   Electrical\nANSI standards as applicable\nVA policies and procedures as provided in contract documents\n\nQualifications of Contractors:\n\nContractors must demonstrate documented experience with electrical safety programs and implementation of OSHA/ANSI LOTO programs in healthcare or similar environments.\n\nCodes and Standards:\n\n29 CFR 1910.147: Control of Hazardous Energy (LOTO)\n29 CFR 1910.301-399, Subpart S: Electrical Standards\nANSI Z244.1   Control of Hazardous Energy\nAll applicable VA policies and regulatory guidance\n\nSpecific Tasks and Deliverables: \n\nDevelop Graphical LOTO Procedures:\nCreate a minimum of 454 equipment-specific, graphical procedures.\nEach procedure shall incorporate direct collaboration with assigned VA electricians for field verification; reliance on drawings alone is not allowed.\nWhere shutdowns are not possible, contractors and VA personnel will create procedures that ensure safe, effective verification of energy isolation.\nProvide and Affix Placards:\nProvide durable, laminated placards for each asset.\nPlacards must be attached to the equipment and clearly display the correct LOTO procedure.\nCreate Documentation Binders:\nTwo tabbed and indexed binders listing all covered equipment, locations, and associated procedures.\nDeliver digital and hard copy files to COR.\nAsset Labeling:\nInclude asset number labels on all covered equipment.\nAnnual Review & Additional Assets:\nPerform annual review; update LOTO program as equipment inventory changes.\nFirst year to cover base list of 137 items from VA Chillicothe Engineering and remaining years to review existing LOTO procedures and make 20 or less asset additions to the LOTO program for any equipment not covered.  Assets to be included in option years will be provided prior to coordinated visits\nTraining:\nTrain an unlimited number of VA staff in both LOTO regulations and facility-specific LOTO procedures.\nInclude hands-on demonstration, ESC and Rockwell tool instruction (Excel-based templates for program customization).\nCollaboration and Scheduling:\nCoordinate with VA Facilities and Engineering to minimize operational disruption.\nProvide service with minimal/no operational downtime. When equipment cannot be shut down, collaborative hazard analysis with VA electricians is required.\n\n\n\nCovered  Equipment: \n\nAll machinery and equipment designated by Chillicothe VAMC Engineering, initially identified as 137 assets and increasing up to 454 during the contract period. Asset lists will be updated at each annual review. A complete inventory will be provided to the Contractor at project initiation and annually thereafter.\n\nHours of Operation: \n\nScheduled service will be performed during normal business hours which considered to be Monday-Friday 7:30am to 4:00pm, (excluding the Federal Holidays of New Year s Day; Martin Luther King Day; President s Day; Memorial Day; Independence Day; Labor Day; Columbus Day; Veteran s Day; Thanksgiving Day; Christmas Day; and any other declared Federal Holiday by the President of the United States).\n\nReporting Requirements: \nThe Contractor shall be required to schedule an appropriate service date with Facilities Management for the equipment to be taken out of service with little or no disruption to the normal operation of the VA Medical Center.  The Contracting Officer Representative (COR) shall have the final approval of the time for the Emergent Maintenance.\n\nContractors shall check in with the Engineering Department currently located on the NE side of Building 21.  Scheduled service will be performed during normal business hours which considered to be Monday-Friday 7:30am to 4:00pm, (excluding the Federal Holidays of New Year s Day; Martin Luther King Day; President s Day; Memorial Day; Independence Day; Labor Day; Columbus Day; Veteran s Day; Thanksgiving Day; Christmas Day; and any other declared Federal Holiday by the President of the United States).  \n\nChecking in is mandatory. When the service is complete, the Contractor shall document services rendered on a legible field service report. The Contractor shall log out at the Facilities Management Office and submit the field service report to the Contracting Officer Representative (COR) for a signature, during normal working hours. \n\nIf this work is to be performed after normal work hours, then check-in will occur with the Utility Systems Employee on Duty, at the Energy Center, Building 261.  This area is staffed 24 hours/day and 7 days a week\n\nSafety Requirements: \n\nIn the performance of this contract, the Contractor shall take such safety precautions as OSHA may determine to be reasonably necessary to protect the lives and health of occupants of the building. The Contracting Officer shall notify the Contractor of any safety issues and the action necessary to correct these issues. Such notice, when served on the Contractor or his representative at the work site shall be deemed sufficient for the corrective actions to be taken. If the Contractor fails or refuses to comply promptly, the Contracting Officer may issue an order stopping all or part of the work and hold the Contractor in default.\n\nGeneral Security:\nContractors, contractor personnel, subcontractors, and subcontractor personnel shall be subject to the same Federal laws, regulations, standards, and VA Directives and Handbooks as VA and VA personnel regarding information and information system security.\n\nContractor is also responsible for checking in with the Engineering Department northeast side of building 21. The contractor will sign out a temporary badge for all contractor/subcontractor personnel.  Every worker must have a badge and form of identification when working on VA property and is subject to VA security checks and enforcement actions while working on VA property.\n\nRisk Control:\n\nWork performed within the Chillicothe VAMC may present health risks including exposure to illness and infection control. Contractor will take action to recognize and follow warning information throughout the facility.\n\n\n\nPerformance Requirements Summary:\n\n\nPWS Task\nPerformance Standard\nAcceptable Quality Level (AQL)\nSurveillance Method\nIncentive\n Rating \n(Met/Not Met AQL)\nDevelop graphical LOTO procedures for all identified assets\n100% completion by end of the contract\n90% Compliance\nInspection and review of contractor records quarterly\nSatisfactory performance results in positive CPARS review\nMet / Not Met\nSubmit LOTO procedure documentation to COR\nProcedures submitted within 30 business days of completion\n90% Compliance\nReview of records and submission dates\nContinued eligibility for future contracts, positive past performance\nMet / Not Met\nAddress identified deficiencies in procedures\nCorrection within 10 business days of notification\n\n100% \nCompliance\nReview of records, inspection follow-up\nNone; Noncompliance may result in a Contract Discrepancy Report (CDR)\nMet / Not Met\nAttach placards to the equipment\n100% completion by end of the contract\n90% Compliance\nDirect observation\nSatisfactory performance results in positive CPARS review\nMet / Not Met\n\n\n\nQuality Control Program Requirement    \nGeneral Requirements: The contractor shall establish, implement and maintain a comprehensive Quality Control Program (QCP) to ensure all services are performed in accordance with the Performance Work Statement and the metrics outlined in the Performance Requirements Summary. \nSubmissions and Updates: The contractor shall submit a detailed written Quality Control Plan the Contracting Officer (CO) and the Contracting Officer s Representative  for review and approval within 14 calendar says of contractor award. Contractor shall update the plan annually or within 7 calendar days of any significant changes to the internal process.\nInspection System: The QCP must detail the Contractors internal inspection mechanics, covering all tasks and deliverables. The plan must specify the metrics tracked, the frequency of internal audits, and identify by name or role the specific personnel responsible for conducting the inspections.\nDeficiency Resolution:  The QCP must include a clear methodology for identifying, tracking and correcting deficiencies in service quality. It must prevent the recurrence of defective work without relying on government intervention. \nRecord Keeping and Audits: The contractor shall maintain records of all internal inspections, including corrective actions taken. These records shall be made available to the government upon request at any point during contract performance. T\nNOTE: The QCP shall be in compliance with the following OSHA standards:\nCode of Federal Regulations, Title 29, part 1910.147,  The Control of Hazardous Energy (Lockout and Tagout) \nCode of Federal Regulations, Title 29, part 1910.301-399, Subpart S,  Electrical \nOSHA Letters of Interpretation","origin":"detail"},"contacts":[{"name":"Lakeisha Jackson","role":"primary","email":"Lakeisha.Jackson@va.gov","phone":"(216) 447-8300 ext. 49622","title":"Contract Specialist"}],"place_of_performance":{"zip":"45601","city":{"name":"Chillicothe"},"state":{"code":"OH"},"street":"Chillicothe Veterans Affairs Medical Center 17273 State Route 104","country":{"code":"USA"}},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"naics_codes":["541690"],"award":null,"attachments":[{"resource_id":"344a0bae234b4a0d8552a04dd112a49b","name":"va.gov","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2026-08-11T17:14:23.241Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov/","mirrored":false}],"awards":[],"related":[{"key":"36C25027Q0014","latest_notice_id":"b13cc87179e947e7b42da2de44a6bde1","title":"J061--541 Electrical Power Distribution Equipment Testing, Inspection, and Maintenance - VAMC Cleveland","solicitation_number":"36C25027Q0014","notice_type":"k","first_type":"k","first_posted":"2026-10-09","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"238210","psc":"J061","set_aside":"SBA","state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C25027Q0123","latest_notice_id":"fb53a332644a4c8fa983bf28c8643d2d","title":"S222--Sources Sought - Hazardous Waste Removal/Disposal Northeast Ohio VA Healthcare System - Cleveland, OH","solicitation_number":"36C25027Q0123","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T18:30:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"562112","psc":"S222","set_aside":null,"state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C25027B0009","latest_notice_id":"85b83d408f1f422885991142c2734b45","title":"Z1DA--FY27 NRM - VISN Base Modernize Nurse Call - 539-23-101","solicitation_number":"36C25027B0009","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"},{"key":"36C25027B0008","latest_notice_id":"5afe716a38494a6f84b1e84205805f86","title":"Z1DA--FY27 NRM - VISN Base Install Roof Equipment Railings - 539-22-206","solicitation_number":"36C25027B0008","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"},{"key":"36C25027B0005","latest_notice_id":"2cb4a6354be04cc89c5d6125945b1892","title":"Z1DA--***FY27 Requirement*** First Floor X Ray - Room CC157 553-CSI-022","solicitation_number":"36C25027B0005","notice_type":"p","first_type":"p","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"MI","county":"26163","county_name":"Wayne County","city":"2622000","city_name":"Detroit","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"}],"similar_open":[{"key":"36C10X27AP0258","latest_notice_id":"e036efc9a96b464fbc236b83dc31bc84","title":"Urgent - Independent Medical Expert Advisory Opinion | Neurosurgery or Orthopedic Surgery","solicitation_number":"36C10X27-AP-0258","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-01T15:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"541690","psc":"Q403","set_aside":null,"state":"DC","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"REQUIREMENTS264330SAM","latest_notice_id":"3a0e86aaf84d4fff9fd8b3e0088f2fdd","title":"NOAA Fisheries RFI - Seafood Supply Chain Mapping, Risk and Re-Import Analysis","solicitation_number":"REQUIREMENTS-26-4330-SAM","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-12-03T00:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-03T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1330","sub_name":"NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION","office_key":"o-1305M3","office_name":"DEPT OF COMMERCE NOAA","naics":"541690","psc":"B548","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2472450","city_name":"Silver Spring","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"ACQCCOP270027SAM","latest_notice_id":"9053e89c23a746019b9bac74b9a3e99d","title":"U.S. Seafood Supply-Chain Mapping, Risk Analysis, and Re-Import Analysis","solicitation_number":"ACQ-CCOP-27-0027-SAM","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-12-03T00:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-03T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1330","sub_name":"NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION","office_key":"o-1305M3","office_name":"DEPT OF COMMERCE NOAA","naics":"541690","psc":"B516","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2472450","city_name":"Silver Spring","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-21T06:18:57.723715Z"}],"similar_open_total":8,"indexable":false}