{"canonical":"https://sealedbidder.com/opportunities/36c25026q0723","key":"36C25026Q0723","url":"https://sealedbidder.com/opportunities/36c25026q0723","title":"J041--Chiller Plant Preventative Maintenance","solicitation_number":"36C25026Q0723","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-07-24T21:00:00Z","first_posted":"2026-07-09","last_posted":"2026-07-09","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"238220","psc":"J041","set_aside":null,"place_state":"IN","place_scope":"site","site":null,"place_state_source":"description","place_evidence":"R (RLRVAMC), 1481 W. 10TH STREET, INDIANAPOLIS, IN 46202","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"56490fbcf4034f9bbb1112e1320396bd","title":"J041--Chiller Plant Preventative Maintenance","solicitation_number":"36C25026Q0723","notice_type":"r","base_type":"r","posted":"2026-07-09","posted_at":"2026-07-09T20:36:14.200Z","due_at":"2026-07-24T21:00:00Z","due_date":"2026-07-24","cancelled":false,"archived":true,"archive_date":"2026-09-22","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/56490fbcf4034f9bbb1112e1320396bd/view","enriched":true,"history":[{"index":1,"title":"J041--Chiller Plant Preventative Maintenance","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-09T20:36:14.200Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"56490fbcf4034f9bbb1112e1320396bd","solicitation_number":"36C25026Q0723"}]}],"latest_notice_id":"56490fbcf4034f9bbb1112e1320396bd","first_type":"r","notices":[{"dates":{"posted":"2026-07-09","posted_at":"2026-07-09T20:36:14.200Z","created_at":"2026-07-09T20:36:11.946Z","modified_at":"2026-07-09T20:36:14.200Z","response_deadline":{"raw":"2026-07-24T17:00:00-04:00","utc":"2026-07-24T21:00:00Z","date":"2026-07-24","time":"17:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/56490fbcf4034f9bbb1112e1320396bd/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"J041--Chiller Plant Preventative Maintenance","agency":{"office":{"code":"36C250","name":"250-NETWORK CONTRACT OFFICE 10 (36C250)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"publication":"published","archive_date":"2026-09-22","archive_type":"auto_custom"},"history":[{"index":1,"title":"J041--Chiller Plant Preventative Maintenance","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-09T20:36:14.200Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"56490fbcf4034f9bbb1112e1320396bd","solicitation_number":"36C25026Q0723"}],"contacts":[{"name":"Jeffrey Rozema","role":"primary","email":"jeffrey.rozema@va.gov","phone":"269-966-5600","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"56490fbcf4034f9bbb1112e1320396bd","lineage_id":"56490fbcf4034f9bbb1112e1320396bd","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-20T03:17:45.201008738Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"99b525a9d05c2b9f7f37756c7edae108-29\"","fetched_at":"2026-09-21T04:08:22.069689491Z","row_sha256":"493099abf6905a117b57d85939c6d2a50d9efa71270a6ea484a596456d7342b2","last_modified":"2026-09-21T03:30:31Z"},"updated_at":"2026-09-21T04:08:22.069689491Z","first_seen_at":"2026-09-16T00:55:28.845070Z"},"description":{"html":"This is a SOURCES SOUGHT request for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time.  \nThis notice is intended strictly for market research.  The purpose of this Sources Sought notice is to determine the interest and capability of businesses to meet the requirements listed below.  \nThe associated North American Industry Classification System (NAICS) Code is 238220   Plumbing, Heating, and Air Conditioning Contractors, and the Business Size Standard is $19.0M.  The associated Product Service Code is J041   Maintenance, Repair, and Rebuilding of Equipment   Refrigeration, Air Conditioning, and Air Circulating Equipment.\nDescription of Requirement:\nThe Richard L Roudebush VA Medical Center has a requirement for preventative maintenance on five centrifugal liquid York chillers, their associated variable frequency drives (VFDs), and monitoring refrigerant leakage from the same chillers. A firm-fixed price service contract with a 1-year base period and two 1-year option periods is anticipated. The base period of performance is anticipated to be November 1, 2026   October 31, 2027.\nAll work will occur at the Richard L. Roudebush VA Medical Center (RLRVAMC), 1481 W. 10th Street, Indianapolis, IN  46202. The facility has a primary/secondary chilled water loop to provide cooling medium for the majority of the air handling units (AHUs) and fan- coil units that distribute cool air to the interior of the buildings. The chiller plant is the sole source of cooling for the facility and has four (4) 1,000-ton and one (1) 500-ton chiller located in Building 23. All chillers are manufactured by York. The variable frequency drives associated with these 1,000-ton chillers are manufactured by Toshiba.  The VFD for the 500-ton chiller is manufactured by York. The chillers and drives are all of the mid 1990s vintage.\nRequired maintenance tasks are as follows:\nPreventative Maintenance / Service Tasks:\nPreventative Maintenance Tasks are required both Quarterly and Annually.  The Annual inspection includes all Quarterly work items and adds some specific additional tasks as identified below.  These tasks as identified below are in addition to any tasks required by the manufacturer.\n\nQuarterly Service Tasks are enumerated below:\n  Provide factory specified PM on four, 1,000-ton and one, 500-ton chillers.\n  Provide factory specified PM for four Toshiba 4,160-volt VFDs and one York VFD 480 volt.\n  Provide the following operational PM on the chillers:\nCheck and tighten all electrical connections, and\nVerify operation/settings/calibration of safety controls and shutdown operation, and\nChange oil filters, and\nChange oil dehydrator, and\nCheck operation of the oil return systems, and\nCheck the oil level (add to oil if oil level is low), and\nCheck the oil sump heaters and the thermostat, and\nCheck operation of the variable speed drive for the oil pump, and\nCheck operation of the oil pump, and\nCheck the operation of the oil pump starter, and\nCheck for three phase voltage and current balance, and\nVerify condenser and evaporator water flow rates, and\nVerify operation of flow switches, and\nLeak check the refrigerant system and repair leaks.\n  Provide the following operational PM on the VFDs:\nClean and inspect all drives, and\nBlow out drives with an inert gas, and\nCheck the components in the drive for heat degradation due to heat or loose connections, and\nClean or replace filters in drive.\n\nAnnual PM tasks are enumerated below:  \n - Provide the following PM service on chillers and drives:\nPerform an oil analysis on the compressor lube oil, and\nPerform a refrigerant analysis, and\nReplace the coolant on the 480 V drive, and\nAll heat exchangers should be cleaned and backwashed, and\nCheck the operation of the starter coolant pump, and\nCheck the voltage and amp draw on the starter coolant pumps, and\nPerform a vibration analysis on all chillers (this may need to be done at a different time from the annual inspection due to chiller loading requirements.\n\n Additional Tasks:\n   Cooling season startup of each chiller includes chillers, drives, controls and associated pumps, and\n\n Refrigerant Related Tasks:\n   Perform refrigerant leak tests during each site visit using certified equipment designed for this purpose, and\n Complete all required documentation including RLR VAMC Refrigerant Equipment Service Form in compliance with 40 CFR Parts 82 & 84, and\n Schedule a second visit within 10 business days after scheduled services to provide additional leak testing to verify refrigerant charge integrity.\n\n Repairs Outside Scope of this Contract:\n   Any repairs required beyond the PM activities required by this contract will be ordered separately under a different contracting means.\n\nContractor Qualifications:\nRequired Certifications:\nThe contractor s personnel shall be certified and trained by York and Toshiba to work on, adjust, repair, and certify operation of York centrifugal chillers and variable frequency drives specifically of the model and type addressed in this SOW. This training shall include design, operation, maintenance and repair activities for these units. Furthermore, the technician shall be certified by the North American Technical Excellence (NATE) organization as to his/her training and experience involving large centrifugal chillers and VFD units. The technician shall also be trained and certified under Section 608 of the Clean Air Act with a Universal certification for working with refrigerant containing equipment and be proficient with 40 CFR Part 84, Subpart C (AIM Act) and Subpart F requirements. \n \nExperience:\nAll technicians must have a minimum of three years verifiable experience in working with centrifugal chillers and VFDs of the type and size as identified for this project.  \n\nRequested Information:\nTo aid acquisition planning, contractors that are interested and capable of meeting this requirement are asked to provide a response via the email address listed below. Please provide at minimum the following information in your response:\n(1) Business name and address\n(2) Point of contact name, phone number and e-mail address \n(3) SAM Unique Entity ID (UEI) \n(4) Socio-economic status\n(5) Any relevant capability information showing ability to meet the requirements listed above.\n\nAdditional information:\nAll contractors must be registered with the System for Award Management (SAM) at https://sam.gov.\nAny contractor that believes they are capable and desires to claim preference for small business status must be registered with the SBA and meet the requirements of FAR 19.103.\nAny contractor that believes they are capable and desires to claim preference for SDVOSB or VOSB status must be registered with the SBA Veteran Small Business Certification Program.\nResponses due to the Contracting Officer, Jeffrey Rozema, by Friday, July 24, 2026, at 5:00 PM Eastern Time.  Please e-mail all responses to jeffrey.rozema@va.gov.","text":"This is a SOURCES SOUGHT request for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time.\nThis notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine the interest and capability of businesses to meet the requirements listed below.\nThe associated North American Industry Classification System (NAICS) Code is 238220 Plumbing, Heating, and Air Conditioning Contractors, and the Business Size Standard is $19.0M. The associated Product Service Code is J041 Maintenance, Repair, and Rebuilding of Equipment Refrigeration, Air Conditioning, and Air Circulating Equipment.\nDescription of Requirement:\nThe Richard L Roudebush VA Medical Center has a requirement for preventative maintenance on five centrifugal liquid York chillers, their associated variable frequency drives (VFDs), and monitoring refrigerant leakage from the same chillers. A firm-fixed price service contract with a 1-year base period and two 1-year option periods is anticipated. The base period of performance is anticipated to be November 1, 2026 October 31, 2027.\nAll work will occur at the Richard L. Roudebush VA Medical Center (RLRVAMC), 1481 W. 10th Street, Indianapolis, IN 46202. The facility has a primary/secondary chilled water loop to provide cooling medium for the majority of the air handling units (AHUs) and fan- coil units that distribute cool air to the interior of the buildings. The chiller plant is the sole source of cooling for the facility and has four (4) 1,000-ton and one (1) 500-ton chiller located in Building 23. All chillers are manufactured by York. The variable frequency drives associated with these 1,000-ton chillers are manufactured by Toshiba. The VFD for the 500-ton chiller is manufactured by York. The chillers and drives are all of the mid 1990s vintage.\nRequired maintenance tasks are as follows:\nPreventative Maintenance / Service Tasks:\nPreventative Maintenance Tasks are required both Quarterly and Annually. The Annual inspection includes all Quarterly work items and adds some specific additional tasks as identified below. These tasks as identified below are in addition to any tasks required by the manufacturer.\n\nQuarterly Service Tasks are enumerated below:\nProvide factory specified PM on four, 1,000-ton and one, 500-ton chillers.\nProvide factory specified PM for four Toshiba 4,160-volt VFDs and one York VFD 480 volt.\nProvide the following operational PM on the chillers:\nCheck and tighten all electrical connections, and\nVerify operation/settings/calibration of safety controls and shutdown operation, and\nChange oil filters, and\nChange oil dehydrator, and\nCheck operation of the oil return systems, and\nCheck the oil level (add to oil if oil level is low), and\nCheck the oil sump heaters and the thermostat, and\nCheck operation of the variable speed drive for the oil pump, and\nCheck operation of the oil pump, and\nCheck the operation of the oil pump starter, and\nCheck for three phase voltage and current balance, and\nVerify condenser and evaporator water flow rates, and\nVerify operation of flow switches, and\nLeak check the refrigerant system and repair leaks.\nProvide the following operational PM on the VFDs:\nClean and inspect all drives, and\nBlow out drives with an inert gas, and\nCheck the components in the drive for heat degradation due to heat or loose connections, and\nClean or replace filters in drive.\n\nAnnual PM tasks are enumerated below:\n- Provide the following PM service on chillers and drives:\nPerform an oil analysis on the compressor lube oil, and\nPerform a refrigerant analysis, and\nReplace the coolant on the 480 V drive, and\nAll heat exchangers should be cleaned and backwashed, and\nCheck the operation of the starter coolant pump, and\nCheck the voltage and amp draw on the starter coolant pumps, and\nPerform a vibration analysis on all chillers (this may need to be done at a different time from the annual inspection due to chiller loading requirements.\n\nAdditional Tasks:\nCooling season startup of each chiller includes chillers, drives, controls and associated pumps, and\n\nRefrigerant Related Tasks:\nPerform refrigerant leak tests during each site visit using certified equipment designed for this purpose, and\nComplete all required documentation including RLR VAMC Refrigerant Equipment Service Form in compliance with 40 CFR Parts 82 & 84, and\nSchedule a second visit within 10 business days after scheduled services to provide additional leak testing to verify refrigerant charge integrity.\n\nRepairs Outside Scope of this Contract:\nAny repairs required beyond the PM activities required by this contract will be ordered separately under a different contracting means.\n\nContractor Qualifications:\nRequired Certifications:\nThe contractor s personnel shall be certified and trained by York and Toshiba to work on, adjust, repair, and certify operation of York centrifugal chillers and variable frequency drives specifically of the model and type addressed in this SOW. This training shall include design, operation, maintenance and repair activities for these units. Furthermore, the technician shall be certified by the North American Technical Excellence (NATE) organization as to his/her training and experience involving large centrifugal chillers and VFD units. The technician shall also be trained and certified under Section 608 of the Clean Air Act with a Universal certification for working with refrigerant containing equipment and be proficient with 40 CFR Part 84, Subpart C (AIM Act) and Subpart F requirements.\n\nExperience:\nAll technicians must have a minimum of three years verifiable experience in working with centrifugal chillers and VFDs of the type and size as identified for this project.\n\nRequested Information:\nTo aid acquisition planning, contractors that are interested and capable of meeting this requirement are asked to provide a response via the email address listed below. Please provide at minimum the following information in your response:\n(1) Business name and address\n(2) Point of contact name, phone number and e-mail address\n(3) SAM Unique Entity ID (UEI)\n(4) Socio-economic status\n(5) Any relevant capability information showing ability to meet the requirements listed above.\n\nAdditional information:\nAll contractors must be registered with the System for Award Management (SAM) at https://sam.gov.\nAny contractor that believes they are capable and desires to claim preference for small business status must be registered with the SBA and meet the requirements of FAR 19.103.\nAny contractor that believes they are capable and desires to claim preference for SDVOSB or VOSB status must be registered with the SBA Veteran Small Business Certification Program.\nResponses due to the Contracting Officer, Jeffrey Rozema, by Friday, July 24, 2026, at 5:00 PM Eastern Time. Please e-mail all responses to jeffrey.rozema@va.gov.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25026Q0723","place_of_performance":{"zip":"46202","city":{"name":"Indianapolis"},"street":"Department of Veterans Affairs Richard L. Roudebush VA Medical Center 1481 W. 10th Street"},"product_service_code":"J041"}],"due_at":"2026-07-24T21:00:00Z","due_date":"2026-07-24","closes_at":"2026-07-24T21:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","state":"IN","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":"description","state_evidence":"R (RLRVAMC), 1481 W. 10TH STREET, INDIANAPOLIS, IN 46202","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-02T08:44:04.547541Z","principal_notice_id":"56490fbcf4034f9bbb1112e1320396bd","description":{"text":"This is a SOURCES SOUGHT request for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time.\nThis notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine the interest and capability of businesses to meet the requirements listed below.\nThe associated North American Industry Classification System (NAICS) Code is 238220 Plumbing, Heating, and Air Conditioning Contractors, and the Business Size Standard is $19.0M. The associated Product Service Code is J041 Maintenance, Repair, and Rebuilding of Equipment Refrigeration, Air Conditioning, and Air Circulating Equipment.\nDescription of Requirement:\nThe Richard L Roudebush VA Medical Center has a requirement for preventative maintenance on five centrifugal liquid York chillers, their associated variable frequency drives (VFDs), and monitoring refrigerant leakage from the same chillers. A firm-fixed price service contract with a 1-year base period and two 1-year option periods is anticipated. The base period of performance is anticipated to be November 1, 2026 October 31, 2027.\nAll work will occur at the Richard L. Roudebush VA Medical Center (RLRVAMC), 1481 W. 10th Street, Indianapolis, IN 46202. The facility has a primary/secondary chilled water loop to provide cooling medium for the majority of the air handling units (AHUs) and fan- coil units that distribute cool air to the interior of the buildings. The chiller plant is the sole source of cooling for the facility and has four (4) 1,000-ton and one (1) 500-ton chiller located in Building 23. All chillers are manufactured by York. The variable frequency drives associated with these 1,000-ton chillers are manufactured by Toshiba. The VFD for the 500-ton chiller is manufactured by York. The chillers and drives are all of the mid 1990s vintage.\nRequired maintenance tasks are as follows:\nPreventative Maintenance / Service Tasks:\nPreventative Maintenance Tasks are required both Quarterly and Annually. The Annual inspection includes all Quarterly work items and adds some specific additional tasks as identified below. These tasks as identified below are in addition to any tasks required by the manufacturer.\n\nQuarterly Service Tasks are enumerated below:\nProvide factory specified PM on four, 1,000-ton and one, 500-ton chillers.\nProvide factory specified PM for four Toshiba 4,160-volt VFDs and one York VFD 480 volt.\nProvide the following operational PM on the chillers:\nCheck and tighten all electrical connections, and\nVerify operation/settings/calibration of safety controls and shutdown operation, and\nChange oil filters, and\nChange oil dehydrator, and\nCheck operation of the oil return systems, and\nCheck the oil level (add to oil if oil level is low), and\nCheck the oil sump heaters and the thermostat, and\nCheck operation of the variable speed drive for the oil pump, and\nCheck operation of the oil pump, and\nCheck the operation of the oil pump starter, and\nCheck for three phase voltage and current balance, and\nVerify condenser and evaporator water flow rates, and\nVerify operation of flow switches, and\nLeak check the refrigerant system and repair leaks.\nProvide the following operational PM on the VFDs:\nClean and inspect all drives, and\nBlow out drives with an inert gas, and\nCheck the components in the drive for heat degradation due to heat or loose connections, and\nClean or replace filters in drive.\n\nAnnual PM tasks are enumerated below:\n- Provide the following PM service on chillers and drives:\nPerform an oil analysis on the compressor lube oil, and\nPerform a refrigerant analysis, and\nReplace the coolant on the 480 V drive, and\nAll heat exchangers should be cleaned and backwashed, and\nCheck the operation of the starter coolant pump, and\nCheck the voltage and amp draw on the starter coolant pumps, and\nPerform a vibration analysis on all chillers (this may need to be done at a different time from the annual inspection due to chiller loading requirements.\n\nAdditional Tasks:\nCooling season startup of each chiller includes chillers, drives, controls and associated pumps, and\n\nRefrigerant Related Tasks:\nPerform refrigerant leak tests during each site visit using certified equipment designed for this purpose, and\nComplete all required documentation including RLR VAMC Refrigerant Equipment Service Form in compliance with 40 CFR Parts 82 & 84, and\nSchedule a second visit within 10 business days after scheduled services to provide additional leak testing to verify refrigerant charge integrity.\n\nRepairs Outside Scope of this Contract:\nAny repairs required beyond the PM activities required by this contract will be ordered separately under a different contracting means.\n\nContractor Qualifications:\nRequired Certifications:\nThe contractor s personnel shall be certified and trained by York and Toshiba to work on, adjust, repair, and certify operation of York centrifugal chillers and variable frequency drives specifically of the model and type addressed in this SOW. This training shall include design, operation, maintenance and repair activities for these units. Furthermore, the technician shall be certified by the North American Technical Excellence (NATE) organization as to his/her training and experience involving large centrifugal chillers and VFD units. The technician shall also be trained and certified under Section 608 of the Clean Air Act with a Universal certification for working with refrigerant containing equipment and be proficient with 40 CFR Part 84, Subpart C (AIM Act) and Subpart F requirements.\n\nExperience:\nAll technicians must have a minimum of three years verifiable experience in working with centrifugal chillers and VFDs of the type and size as identified for this project.\n\nRequested Information:\nTo aid acquisition planning, contractors that are interested and capable of meeting this requirement are asked to provide a response via the email address listed below. Please provide at minimum the following information in your response:\n(1) Business name and address\n(2) Point of contact name, phone number and e-mail address\n(3) SAM Unique Entity ID (UEI)\n(4) Socio-economic status\n(5) Any relevant capability information showing ability to meet the requirements listed above.\n\nAdditional information:\nAll contractors must be registered with the System for Award Management (SAM) at https://sam.gov.\nAny contractor that believes they are capable and desires to claim preference for small business status must be registered with the SBA and meet the requirements of FAR 19.103.\nAny contractor that believes they are capable and desires to claim preference for SDVOSB or VOSB status must be registered with the SBA Veteran Small Business Certification Program.\nResponses due to the Contracting Officer, Jeffrey Rozema, by Friday, July 24, 2026, at 5:00 PM Eastern Time. Please e-mail all responses to jeffrey.rozema@va.gov.","html":"This is a SOURCES SOUGHT request for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time.  \nThis notice is intended strictly for market research.  The purpose of this Sources Sought notice is to determine the interest and capability of businesses to meet the requirements listed below.  \nThe associated North American Industry Classification System (NAICS) Code is 238220   Plumbing, Heating, and Air Conditioning Contractors, and the Business Size Standard is $19.0M.  The associated Product Service Code is J041   Maintenance, Repair, and Rebuilding of Equipment   Refrigeration, Air Conditioning, and Air Circulating Equipment.\nDescription of Requirement:\nThe Richard L Roudebush VA Medical Center has a requirement for preventative maintenance on five centrifugal liquid York chillers, their associated variable frequency drives (VFDs), and monitoring refrigerant leakage from the same chillers. A firm-fixed price service contract with a 1-year base period and two 1-year option periods is anticipated. The base period of performance is anticipated to be November 1, 2026   October 31, 2027.\nAll work will occur at the Richard L. Roudebush VA Medical Center (RLRVAMC), 1481 W. 10th Street, Indianapolis, IN  46202. The facility has a primary/secondary chilled water loop to provide cooling medium for the majority of the air handling units (AHUs) and fan- coil units that distribute cool air to the interior of the buildings. The chiller plant is the sole source of cooling for the facility and has four (4) 1,000-ton and one (1) 500-ton chiller located in Building 23. All chillers are manufactured by York. The variable frequency drives associated with these 1,000-ton chillers are manufactured by Toshiba.  The VFD for the 500-ton chiller is manufactured by York. The chillers and drives are all of the mid 1990s vintage.\nRequired maintenance tasks are as follows:\nPreventative Maintenance / Service Tasks:\nPreventative Maintenance Tasks are required both Quarterly and Annually.  The Annual inspection includes all Quarterly work items and adds some specific additional tasks as identified below.  These tasks as identified below are in addition to any tasks required by the manufacturer.\n\nQuarterly Service Tasks are enumerated below:\n  Provide factory specified PM on four, 1,000-ton and one, 500-ton chillers.\n  Provide factory specified PM for four Toshiba 4,160-volt VFDs and one York VFD 480 volt.\n  Provide the following operational PM on the chillers:\nCheck and tighten all electrical connections, and\nVerify operation/settings/calibration of safety controls and shutdown operation, and\nChange oil filters, and\nChange oil dehydrator, and\nCheck operation of the oil return systems, and\nCheck the oil level (add to oil if oil level is low), and\nCheck the oil sump heaters and the thermostat, and\nCheck operation of the variable speed drive for the oil pump, and\nCheck operation of the oil pump, and\nCheck the operation of the oil pump starter, and\nCheck for three phase voltage and current balance, and\nVerify condenser and evaporator water flow rates, and\nVerify operation of flow switches, and\nLeak check the refrigerant system and repair leaks.\n  Provide the following operational PM on the VFDs:\nClean and inspect all drives, and\nBlow out drives with an inert gas, and\nCheck the components in the drive for heat degradation due to heat or loose connections, and\nClean or replace filters in drive.\n\nAnnual PM tasks are enumerated below:  \n - Provide the following PM service on chillers and drives:\nPerform an oil analysis on the compressor lube oil, and\nPerform a refrigerant analysis, and\nReplace the coolant on the 480 V drive, and\nAll heat exchangers should be cleaned and backwashed, and\nCheck the operation of the starter coolant pump, and\nCheck the voltage and amp draw on the starter coolant pumps, and\nPerform a vibration analysis on all chillers (this may need to be done at a different time from the annual inspection due to chiller loading requirements.\n\n Additional Tasks:\n   Cooling season startup of each chiller includes chillers, drives, controls and associated pumps, and\n\n Refrigerant Related Tasks:\n   Perform refrigerant leak tests during each site visit using certified equipment designed for this purpose, and\n Complete all required documentation including RLR VAMC Refrigerant Equipment Service Form in compliance with 40 CFR Parts 82 & 84, and\n Schedule a second visit within 10 business days after scheduled services to provide additional leak testing to verify refrigerant charge integrity.\n\n Repairs Outside Scope of this Contract:\n   Any repairs required beyond the PM activities required by this contract will be ordered separately under a different contracting means.\n\nContractor Qualifications:\nRequired Certifications:\nThe contractor s personnel shall be certified and trained by York and Toshiba to work on, adjust, repair, and certify operation of York centrifugal chillers and variable frequency drives specifically of the model and type addressed in this SOW. This training shall include design, operation, maintenance and repair activities for these units. Furthermore, the technician shall be certified by the North American Technical Excellence (NATE) organization as to his/her training and experience involving large centrifugal chillers and VFD units. The technician shall also be trained and certified under Section 608 of the Clean Air Act with a Universal certification for working with refrigerant containing equipment and be proficient with 40 CFR Part 84, Subpart C (AIM Act) and Subpart F requirements. \n \nExperience:\nAll technicians must have a minimum of three years verifiable experience in working with centrifugal chillers and VFDs of the type and size as identified for this project.  \n\nRequested Information:\nTo aid acquisition planning, contractors that are interested and capable of meeting this requirement are asked to provide a response via the email address listed below. Please provide at minimum the following information in your response:\n(1) Business name and address\n(2) Point of contact name, phone number and e-mail address \n(3) SAM Unique Entity ID (UEI) \n(4) Socio-economic status\n(5) Any relevant capability information showing ability to meet the requirements listed above.\n\nAdditional information:\nAll contractors must be registered with the System for Award Management (SAM) at https://sam.gov.\nAny contractor that believes they are capable and desires to claim preference for small business status must be registered with the SBA and meet the requirements of FAR 19.103.\nAny contractor that believes they are capable and desires to claim preference for SDVOSB or VOSB status must be registered with the SBA Veteran Small Business Certification Program.\nResponses due to the Contracting Officer, Jeffrey Rozema, by Friday, July 24, 2026, at 5:00 PM Eastern Time.  Please e-mail all responses to jeffrey.rozema@va.gov.","origin":"detail"},"contacts":[{"name":"Jeffrey Rozema","role":"primary","email":"jeffrey.rozema@va.gov","phone":"269-966-5600","title":"Contracting Officer"}],"place_of_performance":{"zip":"46202","city":{"name":"Indianapolis"},"street":"Department of Veterans Affairs Richard L. Roudebush VA Medical Center 1481 W. 10th Street"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"naics_codes":["238220"],"award":null,"attachments":[{"resource_id":"937e24dfdaac48389549a8b98f28cf09","name":"36C25026Q0723.docx","kind":"file","mime_type":".docx","size_bytes":30049,"posted_at":"2026-07-09T20:36:14.200Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/937e24dfdaac48389549a8b98f28cf09/download","mirrored":false}],"awards":[],"related":[{"key":"36C25027Q0014","latest_notice_id":"b13cc87179e947e7b42da2de44a6bde1","title":"J061--541 Electrical Power Distribution Equipment Testing, Inspection, and Maintenance - VAMC Cleveland","solicitation_number":"36C25027Q0014","notice_type":"k","first_type":"k","first_posted":"2026-10-09","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"238210","psc":"J061","set_aside":"SBA","state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C25027Q0123","latest_notice_id":"fb53a332644a4c8fa983bf28c8643d2d","title":"S222--Sources Sought - Hazardous Waste Removal/Disposal Northeast Ohio VA Healthcare System - Cleveland, OH","solicitation_number":"36C25027Q0123","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T18:30:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"562112","psc":"S222","set_aside":null,"state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C25027B0009","latest_notice_id":"85b83d408f1f422885991142c2734b45","title":"Z1DA--FY27 NRM - VISN Base Modernize Nurse Call - 539-23-101","solicitation_number":"36C25027B0009","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"},{"key":"36C25027B0008","latest_notice_id":"5afe716a38494a6f84b1e84205805f86","title":"Z1DA--FY27 NRM - VISN Base Install Roof Equipment Railings - 539-22-206","solicitation_number":"36C25027B0008","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"},{"key":"36C25027B0005","latest_notice_id":"2cb4a6354be04cc89c5d6125945b1892","title":"Z1DA--***FY27 Requirement*** First Floor X Ray - Room CC157 553-CSI-022","solicitation_number":"36C25027B0005","notice_type":"p","first_type":"p","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"MI","county":"26163","county_name":"Wayne County","city":"2622000","city_name":"Detroit","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"}],"similar_open":[{"key":"140FF027Q0080","latest_notice_id":"c706d18cc5e846508a63090d29caa934","title":"AK-AK MARITIME NWR-LEAK REPAIR","solicitation_number":"140FF027Q0080","notice_type":"o","first_type":"o","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-26T17:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-014","dept_name":"INTERIOR, DEPARTMENT OF THE","sub_key":"s-1406","sub_name":"DEPARTMENTAL OFFICES","office_key":"o-140FF0","office_name":"FWS CONTRACTING ACTIVITY","naics":"238220","psc":"J045","set_aside":"SBA","state":"AK","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"title","state_evidence":"AK-A","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"36C26227Q0149","latest_notice_id":"99fd06e3089e4005bf945b21581e7d70","title":"J065--BRINE MAINTENANCE SVC - Base +4 OY ($0.00) [605] | POP: 01/01/2027 - 12/31/2031","solicitation_number":"36C26227Q0149","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"238220","psc":"J065","set_aside":"SDVOSBC","state":"CA","county":"06071","county_name":"San Bernardino County","city":"0642370","city_name":"Loma Linda","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T07:05:05.540398Z"},{"key":"36C25927Q0048","latest_notice_id":"c63e9c1e32f4475caa79c878ba87ca2f","title":"Radiant Heating Panel Replacement","solicitation_number":"36C25927Q0048","notice_type":"k","first_type":"k","first_posted":"2026-11-04","last_posted":"2026-11-23","notices":3,"due_at":"2026-11-27T19:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"238220","psc":"J045","set_aside":"SBA","state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"}],"similar_open_total":56,"indexable":false}