{"canonical":"https://sealedbidder.com/opportunities/36c25026q0636","key":"36C25026Q0636","url":"https://sealedbidder.com/opportunities/36c25026q0636","title":"36C25026P0866 Manometry Probes SPS - Cincinnati PO 539A60196","solicitation_number":"36C25026Q0636","notice_type":"a","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-06-22T20:00:00Z","first_posted":"2026-06-09","last_posted":"2026-09-03","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"339112","psc":"6515","set_aside":null,"place_state":"OH","place_scope":"nationwide","site":"Cincinnati VA Medical Center","place_state_source":null,"place_evidence":"Product purchase (PSC 6515)","place_county":"39061","place_county_name":"Hamilton County","place_city":"3915000","place_city_name":"Cincinnati","winner":"COVIDIEN SALES LLC","award_amount":"115352.00","publications":[{"notice_id":"056ccc7739694d7a97917c7f777b0881","title":"6515--Manometry Probes SPS - Brand Name Only Cincinnati VAMC","solicitation_number":"36C25026Q0636","notice_type":"k","base_type":"k","posted":"2026-06-09","posted_at":"2026-06-09T17:01:27.144Z","due_at":"2026-06-22T20:00:00Z","due_date":"2026-06-22","cancelled":false,"archived":true,"archive_date":"2026-07-22","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/056ccc7739694d7a97917c7f777b0881/view","enriched":true,"history":[{"index":4,"title":"6515--Manometry Probes SPS - Brand Name Only Cincinnati VAMC","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-01T21:43:48.277Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"8c96966192d14153b1bad3841c7eec91","solicitation_number":"36C25026Q0636","parent_opportunity_id":"056ccc7739694d7a97917c7f777b0881"},{"index":3,"title":"6515--Manometry Probes SPS - Brand Name Only Cincinnati VAMC","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-09T17:01:27.144Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"056ccc7739694d7a97917c7f777b0881","solicitation_number":"36C25026Q0636"}]},{"notice_id":"8c96966192d14153b1bad3841c7eec91","title":"6515--Manometry Probes SPS - Brand Name Only Cincinnati VAMC","solicitation_number":"36C25026Q0636","notice_type":"k","base_type":"k","posted":"2026-09-01","posted_at":"2026-09-01T21:43:48.277Z","due_at":"2026-06-22T20:00:00Z","due_date":"2026-06-22","cancelled":false,"archived":true,"archive_date":"2026-10-22","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/8c96966192d14153b1bad3841c7eec91/view","enriched":true,"history":[{"index":4,"title":"6515--Manometry Probes SPS - Brand Name Only Cincinnati VAMC","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-01T21:43:48.277Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"8c96966192d14153b1bad3841c7eec91","solicitation_number":"36C25026Q0636","parent_opportunity_id":"056ccc7739694d7a97917c7f777b0881"},{"index":3,"title":"6515--Manometry Probes SPS - Brand Name Only Cincinnati VAMC","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-09T17:01:27.144Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"056ccc7739694d7a97917c7f777b0881","solicitation_number":"36C25026Q0636"}]},{"notice_id":"be63cb396d2e4b8bb4300e6062b4d12b","title":"36C25026P0866 Manometry Probes SPS - Cincinnati PO 539A60196","solicitation_number":"36C25026P0866","notice_type":"a","base_type":"a","posted":"2026-09-03","posted_at":"2026-09-03T18:48:28.803Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-09-16","removed_at":null,"award_number":"36C25026P0866","awardee_name":"COVIDIEN SALES LLC","amount":"115352.00","link_sam":"https://sam.gov/workspace/contract/opp/be63cb396d2e4b8bb4300e6062b4d12b/view","enriched":true,"history":[{"index":3,"title":"36C25026P0866 Manometry Probes SPS - Cincinnati PO 539A60196","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-09-03T18:48:28.803Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"be63cb396d2e4b8bb4300e6062b4d12b","solicitation_number":"36C25026P0866"}]}],"latest_notice_id":"be63cb396d2e4b8bb4300e6062b4d12b","first_type":"k","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-06-09","posted_at":"2026-06-09T17:01:27.144Z","created_at":"2026-06-09T17:01:24.671Z","modified_at":"2026-09-01T21:43:48.277Z","response_deadline":{"raw":"2026-06-22T16:00:00-04:00","utc":"2026-06-22T20:00:00Z","date":"2026-06-22","time":"16:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/056ccc7739694d7a97917c7f777b0881/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"6515--Manometry Probes SPS - Brand Name Only Cincinnati VAMC","agency":{"office":{"code":"36C250","name":"250-NETWORK CONTRACT OFFICE 10 (36C250)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"organization_id":"100167099","organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-07-22","archive_type":"auto_custom"},"history":[{"index":4,"title":"6515--Manometry Probes SPS - Brand Name Only Cincinnati VAMC","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-01T21:43:48.277Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"8c96966192d14153b1bad3841c7eec91","solicitation_number":"36C25026Q0636","parent_opportunity_id":"056ccc7739694d7a97917c7f777b0881"},{"index":3,"title":"6515--Manometry Probes SPS - Brand Name Only Cincinnati VAMC","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-09T17:01:27.144Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"056ccc7739694d7a97917c7f777b0881","solicitation_number":"36C25026Q0636"}],"contacts":[{"name":"Barbara Robertson","role":"primary","email":"Barbara.Robertson@va.gov","phone":"(513)861-3100","title":"Contracting Specialist"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"056ccc7739694d7a97917c7f777b0881","lineage_id":"056ccc7739694d7a97917c7f777b0881","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-21T01:02:08.055546270Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"3f59209463433eba6899e195a597c64d-29\"","fetched_at":"2026-09-16T16:22:40.277975Z","row_sha256":"249a9527293096c3549d3b22fcab7a7c028e04004a217c68ad15d91b4773d11d","last_modified":"2026-09-16T03:30:52Z"},"updated_at":"2026-09-21T01:02:08.055546270Z","first_seen_at":"2026-09-16T16:22:40.277975Z"},"description":{"html":"Department of Veterans Affairs, Network Contracting Office 10 located at 260 E University Avenue, Cincinnati, OH 45219-2356, in support of VISN 10, Cincinnati Veterans Affairs Medical Center (CVAMC) Sterile Processing Department, located at 3200 Vine Street, Cincinnati, OH 45220-2213 is seeking a firm-fixed-price contract to procure brand name only Manometry Probes.","text":"Department of Veterans Affairs, Network Contracting Office 10 located at 260 E University Avenue, Cincinnati, OH 45219-2356, in support of VISN 10, Cincinnati Veterans Affairs Medical Center (CVAMC) Sterile Processing Department, located at 3200 Vine Street, Cincinnati, OH 45220-2213 is seeking a firm-fixed-price contract to procure brand name only Manometry Probes.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C25026Q0636","place_of_performance":{"zip":"45220-2213","city":{"code":"15000","name":"Cincinnati"},"state":{"code":"OH","name":"Ohio"},"street":"Department of Veterans Affairs","country":{"code":"USA","name":"UNITED STATES"},"street2":"Cincinnati VAMC 3200 Vine Street"},"product_service_code":"6515"},{"dates":{"posted":"2026-09-01","posted_at":"2026-09-01T21:43:48.277Z","created_at":"2026-09-01T21:43:48.277Z","modified_at":"2026-09-01T21:43:48.277Z","response_deadline":{"raw":"2026-06-22T16:00:00-04:00","utc":"2026-06-22T20:00:00Z","date":"2026-06-22","time":"16:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/8c96966192d14153b1bad3841c7eec91/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"6515--Manometry Probes SPS - Brand Name Only Cincinnati VAMC","agency":{"office":{"code":"36C250","name":"250-NETWORK CONTRACT OFFICE 10 (36C250)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"publication":"published","archive_date":"2026-10-22","archive_type":"auto_custom"},"history":[{"index":4,"title":"6515--Manometry Probes SPS - Brand Name Only Cincinnati VAMC","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-01T21:43:48.277Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"8c96966192d14153b1bad3841c7eec91","solicitation_number":"36C25026Q0636","parent_opportunity_id":"056ccc7739694d7a97917c7f777b0881"},{"index":3,"title":"6515--Manometry Probes SPS - Brand Name Only Cincinnati VAMC","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-09T17:01:27.144Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"056ccc7739694d7a97917c7f777b0881","solicitation_number":"36C25026Q0636"}],"contacts":[{"name":"Barbara Robertson","role":"primary","email":"Barbara.Robertson@va.gov","phone":"(513)861-3100","title":"Contracting Specialist"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"8c96966192d14153b1bad3841c7eec91","lineage_id":"056ccc7739694d7a97917c7f777b0881","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-17T02:30:10.534926303Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"e3d4122fdf092f2335c42225efa68564a4ff94bd32a2a9f7fa2f69e1f5eaf661","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-09-15T22:52:52.472456Z"},"description":{"html":"Department of Veterans Affairs, Network Contracting Office 10 located at 260 E University Avenue, Cincinnati, OH 45219-2356, in support of VISN 10, Cincinnati Veterans Affairs Medical Center (CVAMC) Sterile Processing Department, located at 3200 Vine Street, Cincinnati, OH 45220-2213 is seeking a firm-fixed-price contract to procure brand name only Manometry Probes.","text":"Department of Veterans Affairs, Network Contracting Office 10 located at 260 E University Avenue, Cincinnati, OH 45219-2356, in support of VISN 10, Cincinnati Veterans Affairs Medical Center (CVAMC) Sterile Processing Department, located at 3200 Vine Street, Cincinnati, OH 45220-2213 is seeking a firm-fixed-price contract to procure brand name only Manometry Probes.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C25026Q0636","place_of_performance":{"zip":"45220-2213","city":{"name":"Cincinnati"},"state":{"code":"OH"},"street":"Department of Veterans Affairs Cincinnati VAMC 3200 Vine Street","country":{"code":"USA"}},"product_service_code":"6515"},{"award":{"date":"2026-09-01","amount":"115352.00","number":"36C25026P0866","awardee":{"raw":"COVIDIEN SALES LLC Mansfield MA 02048 USA","name":"COVIDIEN SALES LLC","location":{"zip":"02048","city":{"code":"38225","name":"Mansfield"},"state":{"code":"MA","name":"Massachusetts"},"country":{"code":"USA","name":"UNITED STATES"}}}},"dates":{"posted":"2026-09-03","posted_at":"2026-09-03T18:48:28.803Z","award_date":"2026-09-01","created_at":"2026-09-03T18:38:23.327Z","modified_at":"2026-09-16T05:08:29.027Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/be63cb396d2e4b8bb4300e6062b4d12b/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"36C25026P0866 Manometry Probes SPS - Cincinnati PO 539A60196","agency":{"office":{"code":"36C250","name":"250-NETWORK CONTRACT OFFICE 10 (36C250)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"organization_id":"100167099","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-09-16","archive_type":"auto15"},"history":[{"index":3,"title":"36C25026P0866 Manometry Probes SPS - Cincinnati PO 539A60196","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-09-03T18:48:28.803Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"be63cb396d2e4b8bb4300e6062b4d12b","solicitation_number":"36C25026P0866"}],"contacts":[{"name":"Barbara Robertson","role":"primary","email":"Barbara.Roberton@va.gov","phone":"5138613100"}],"base_type":{"code":"a","label":"Award Notice"},"notice_id":"be63cb396d2e4b8bb4300e6062b4d12b","lineage_id":"be63cb396d2e4b8bb4300e6062b4d12b","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-24T03:47:25.439628032Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"3f59209463433eba6899e195a597c64d-29\"","fetched_at":"2026-09-16T07:50:12.777658Z","row_sha256":"841c744d8d50fc18d559dc4197360508aaf64ea6eb46b1e143c8c35f5b529f08","last_modified":"2026-09-16T03:30:52Z"},"updated_at":"2026-09-24T03:47:25.439628032Z","first_seen_at":"2026-09-15T22:52:52.472456Z"},"description":{"html":"<p><strong>DEPARTMENT OF VETERANS AFFAIRS</strong></p>\n\n<p></p>\n\n<p><strong>Justification for Single Source Awards IAW FAR 13.106-1</strong></p>\n\n<p><strong>For</strong></p>\n\n<p><strong>Over Micro-Purchase Threshold but Not Exceeding the Simplified Acquisition Threshold</strong></p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>Acquisition Plan Action ID: <u>36C250-26-AP-2650</u></strong></p>\n\n<p></p>\n\n<ol>\n\t<li><strong><u>Contracting Activity</u></strong><strong>:</strong>&nbsp; Department of Veterans Affairs, Network Contracting Office 10 located at 260 E University Avenue, Cincinnati, OH 45219-2356, in support of VISN 10, Cincinnati VA Medical Center (VAMC), 3200 Vine Street, Cincinnati, OH 45220-2213. 2237 #: 539-26-2-043-0148</li>\n</ol>\n\n<p></p>\n\n<p></p>\n\n<ol>\n\t<li><strong>Brief Description of Supplies/ Services required and the intended use/Estimated Amount:</strong>&nbsp; Clinicians in the Speech and Endoscopy clinics at CVAMC operates Government owned high-resolution manometry (HRM) systems to perform diagnostic esophageal motility studies to determine the root cause of symptoms, diagnose esophageal disorders and personalize their approach to manage the care of esophageal patients.</li>\n</ol>\n\n<p></p>\n\n<p>The manometry probe (or catheter) required to operate the HRM system is&nbsp;a thin, flexible tube equipped with sensors, inserted through the nose or mouth into the gastrointestinal tract to measure muscle pressure and coordination.&nbsp;</p>\n\n<p></p>\n\n<p>This new request is for a one-time firm-fixed-price contract to procure replacement manometry probes compatible with the HRM system that are at end of lifecycle.&nbsp; The supplies/services needed are:</p>\n\n<p></p>\n\n<ul>\n\t<li>Manoscan ESO Z CATH X1 &ndash; Mfr. Part #:&nbsp; 3890 &ndash; Quantity of 4 Each</li>\n\t<li>HRM Catheter Extended&nbsp; WARRANTY 1 YEAR &ndash; Mfr. Part #: 80372 &ndash; Quantity of 4 Each</li>\n\t<li>Shipping and Handling (Estimated) &ndash; Quantity of 1 Each</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;</p>\n\n<ol>\n\t<li><strong>Unique characteristics that limit availability to only one source, with the reason no other supplies or services can be used:</strong> The ManoView manometry system is a proprietary platform that requires OEM manufactured ManoScan catheters for operation. These catheters utilize proprietary connectors, hardware interfaces, and system recognition features that are unique to Medtronic equipment.</li>\n</ol>\n\n<p></p>\n\n<p>The HRM system requires OEM-compatible manometry probes to avoid calibration drift, invalid pressure profiles, and adverse impact on clinical decisions. Probes from non‑OEM sources are not validated with this system&rsquo;s firmware and sterile pathway, creating risk to patient safety and data integrity. Medical device accessories must be assessed in context of the parent device; compatibility and risk controls apply. The equipment must meet the following minimum salient characteristics:</p>\n\n<p></p>\n\n<ol>\n\t<li><strong><u>Sensor &amp; Catheter Specifications</u></strong></li>\n</ol>\n\n<p></p>\n\n<p>This section is intentionally left blank.</p>\n\n<p></p>\n\n<ol>\n\t<li><strong><u>Coverage &amp; Mapping Capabilities</u></strong></li>\n</ol>\n\n<p></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp; This section is intentionally left blank.</p>\n\n<p></p>\n\n<ol>\n\t<li><strong><u>Diagnostic Enhancements</u></strong></li>\n</ol>\n\n<p></p>\n\n<p>This section is intentionally left blank.</p>\n\n<p></p>\n\n<ol>\n\t<li><strong><u>Software Functions</u></strong></li>\n</ol>\n\n<p></p>\n\n<p>This section is intentionally left blank.</p>\n\n<p></p>\n\n<ol>\n\t<li><strong><u>Efficiency &amp; Training</u></strong></li>\n</ol>\n\n<p></p>\n\n<p>This section is intentionally left blank.</p>\n\n<p></p>\n\n<ol>\n\t<li><strong>Description of market research conducted and results or statement why it was not conducted:</strong>&nbsp; The CVAMC SPS initiated market research in December 2025 to determine the facility&rsquo;s needs and market availability.&nbsp; The LB OEM provided an informal quote and none of the items were found to be offered on FSS contract.</li>\n</ol>\n\n<p></p>\n\n<p>Additional market queries were conducted by the Contracting Specialist using SBA&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;SBS, SAM.gov, GSA Advantage, VA NAC, and ADDS UP databases.&nbsp; There were</p>\n\n<p>multiple entries found for various types of catheters offered by others in the industry.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;None of those items are compatible with the Government owned HRM equipment at&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; the facility and capable of meeting this requirement.&nbsp; The product NAICS code was &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;not found in the NMR class waiver database.</p>\n\n<p></p>\n\n<p>Direct contact was made with the LB OEM.&nbsp; The OEM confirmed the country of &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;orgin (COO) for the equipment is Vietnam and that pricing is open market.&nbsp; They &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;also identified three (3) SBA SBS verified SDVOSB authorized distributors.</p>\n\n<p></p>\n\n<p>Due to the NMR findings, an SDVOSB, VOSB set-aside is prohibited.&nbsp; The VA and Rule of Two cannot be met. The SBA Rule of Two is obtainable.&nbsp; A small business set-aside solicitation for brand name equipment will be posted to the Governmentwide point of entry (GPE) to obtain fair and reasonable pricing.</p>","text":"DEPARTMENT OF VETERANS AFFAIRS\n\nJustification for Single Source Awards IAW FAR 13.106-1\n\nFor\n\nOver Micro-Purchase Threshold but Not Exceeding the Simplified Acquisition Threshold\n\nAcquisition Plan Action ID: 36C250-26-AP-2650\n\n• Contracting Activity: Department of Veterans Affairs, Network Contracting Office 10 located at 260 E University Avenue, Cincinnati, OH 45219-2356, in support of VISN 10, Cincinnati VA Medical Center (VAMC), 3200 Vine Street, Cincinnati, OH 45220-2213. 2237 #: 539-26-2-043-0148\n\n• Brief Description of Supplies/ Services required and the intended use/Estimated Amount: Clinicians in the Speech and Endoscopy clinics at CVAMC operates Government owned high-resolution manometry (HRM) systems to perform diagnostic esophageal motility studies to determine the root cause of symptoms, diagnose esophageal disorders and personalize their approach to manage the care of esophageal patients.\n\nThe manometry probe (or catheter) required to operate the HRM system is a thin, flexible tube equipped with sensors, inserted through the nose or mouth into the gastrointestinal tract to measure muscle pressure and coordination.\n\nThis new request is for a one-time firm-fixed-price contract to procure replacement manometry probes compatible with the HRM system that are at end of lifecycle. The supplies/services needed are:\n\n• Manoscan ESO Z CATH X1 – Mfr. Part #: 3890 – Quantity of 4 Each\n\n• HRM Catheter Extended WARRANTY 1 YEAR – Mfr. Part #: 80372 – Quantity of 4 Each\n\n• Shipping and Handling (Estimated) – Quantity of 1 Each\n\n• Unique characteristics that limit availability to only one source, with the reason no other supplies or services can be used: The ManoView manometry system is a proprietary platform that requires OEM manufactured ManoScan catheters for operation. These catheters utilize proprietary connectors, hardware interfaces, and system recognition features that are unique to Medtronic equipment.\n\nThe HRM system requires OEM-compatible manometry probes to avoid calibration drift, invalid pressure profiles, and adverse impact on clinical decisions. Probes from non‑OEM sources are not validated with this system’s firmware and sterile pathway, creating risk to patient safety and data integrity. Medical device accessories must be assessed in context of the parent device; compatibility and risk controls apply. The equipment must meet the following minimum salient characteristics:\n\n• Sensor & Catheter Specifications\n\nThis section is intentionally left blank.\n\n• Coverage & Mapping Capabilities\n\nThis section is intentionally left blank.\n\n• Diagnostic Enhancements\n\nThis section is intentionally left blank.\n\n• Software Functions\n\nThis section is intentionally left blank.\n\n• Efficiency & Training\n\nThis section is intentionally left blank.\n\n• Description of market research conducted and results or statement why it was not conducted: The CVAMC SPS initiated market research in December 2025 to determine the facility’s needs and market availability. The LB OEM provided an informal quote and none of the items were found to be offered on FSS contract.\n\nAdditional market queries were conducted by the Contracting Specialist using SBA SBS, SAM.gov, GSA Advantage, VA NAC, and ADDS UP databases. There were\n\nmultiple entries found for various types of catheters offered by others in the industry. None of those items are compatible with the Government owned HRM equipment at the facility and capable of meeting this requirement. The product NAICS code was not found in the NMR class waiver database.\n\nDirect contact was made with the LB OEM. The OEM confirmed the country of orgin (COO) for the equipment is Vietnam and that pricing is open market. They also identified three (3) SBA SBS verified SDVOSB authorized distributors.\n\nDue to the NMR findings, an SDVOSB, VOSB set-aside is prohibited. The VA and Rule of Two cannot be met. The SBA Rule of Two is obtainable. A small business set-aside solicitation for brand name equipment will be posted to the Governmentwide point of entry (GPE) to obtain fair and reasonable pricing.","origin":"detail"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"36C25026P0866","product_service_code":"6515"}],"due_at":"2026-06-22T20:00:00Z","due_date":"2026-06-22","closes_at":"2026-06-22T20:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","state":"OH","county":"39061","county_name":"Hamilton County","city":"3915000","city_name":"Cincinnati","country":"USA","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site_key":"cincinnati-va-medical-center-oh","winner_key":"NJCGNFB43XK1","amount":"115352.00","linked_awards":3,"cancelled":false,"archived":true,"updated_at":"2026-09-24T04:24:26.592861Z","principal_notice_id":"be63cb396d2e4b8bb4300e6062b4d12b","description":{"text":"DEPARTMENT OF VETERANS AFFAIRS\n\nJustification for Single Source Awards IAW FAR 13.106-1\n\nFor\n\nOver Micro-Purchase Threshold but Not Exceeding the Simplified Acquisition Threshold\n\nAcquisition Plan Action ID: 36C250-26-AP-2650\n\n• Contracting Activity: Department of Veterans Affairs, Network Contracting Office 10 located at 260 E University Avenue, Cincinnati, OH 45219-2356, in support of VISN 10, Cincinnati VA Medical Center (VAMC), 3200 Vine Street, Cincinnati, OH 45220-2213. 2237 #: 539-26-2-043-0148\n\n• Brief Description of Supplies/ Services required and the intended use/Estimated Amount: Clinicians in the Speech and Endoscopy clinics at CVAMC operates Government owned high-resolution manometry (HRM) systems to perform diagnostic esophageal motility studies to determine the root cause of symptoms, diagnose esophageal disorders and personalize their approach to manage the care of esophageal patients.\n\nThe manometry probe (or catheter) required to operate the HRM system is a thin, flexible tube equipped with sensors, inserted through the nose or mouth into the gastrointestinal tract to measure muscle pressure and coordination.\n\nThis new request is for a one-time firm-fixed-price contract to procure replacement manometry probes compatible with the HRM system that are at end of lifecycle. The supplies/services needed are:\n\n• Manoscan ESO Z CATH X1 – Mfr. Part #: 3890 – Quantity of 4 Each\n\n• HRM Catheter Extended WARRANTY 1 YEAR – Mfr. Part #: 80372 – Quantity of 4 Each\n\n• Shipping and Handling (Estimated) – Quantity of 1 Each\n\n• Unique characteristics that limit availability to only one source, with the reason no other supplies or services can be used: The ManoView manometry system is a proprietary platform that requires OEM manufactured ManoScan catheters for operation. These catheters utilize proprietary connectors, hardware interfaces, and system recognition features that are unique to Medtronic equipment.\n\nThe HRM system requires OEM-compatible manometry probes to avoid calibration drift, invalid pressure profiles, and adverse impact on clinical decisions. Probes from non‑OEM sources are not validated with this system’s firmware and sterile pathway, creating risk to patient safety and data integrity. Medical device accessories must be assessed in context of the parent device; compatibility and risk controls apply. The equipment must meet the following minimum salient characteristics:\n\n• Sensor & Catheter Specifications\n\nThis section is intentionally left blank.\n\n• Coverage & Mapping Capabilities\n\nThis section is intentionally left blank.\n\n• Diagnostic Enhancements\n\nThis section is intentionally left blank.\n\n• Software Functions\n\nThis section is intentionally left blank.\n\n• Efficiency & Training\n\nThis section is intentionally left blank.\n\n• Description of market research conducted and results or statement why it was not conducted: The CVAMC SPS initiated market research in December 2025 to determine the facility’s needs and market availability. The LB OEM provided an informal quote and none of the items were found to be offered on FSS contract.\n\nAdditional market queries were conducted by the Contracting Specialist using SBA SBS, SAM.gov, GSA Advantage, VA NAC, and ADDS UP databases. There were\n\nmultiple entries found for various types of catheters offered by others in the industry. None of those items are compatible with the Government owned HRM equipment at the facility and capable of meeting this requirement. The product NAICS code was not found in the NMR class waiver database.\n\nDirect contact was made with the LB OEM. The OEM confirmed the country of orgin (COO) for the equipment is Vietnam and that pricing is open market. They also identified three (3) SBA SBS verified SDVOSB authorized distributors.\n\nDue to the NMR findings, an SDVOSB, VOSB set-aside is prohibited. The VA and Rule of Two cannot be met. The SBA Rule of Two is obtainable. A small business set-aside solicitation for brand name equipment will be posted to the Governmentwide point of entry (GPE) to obtain fair and reasonable pricing.","html":"<p><strong>DEPARTMENT OF VETERANS AFFAIRS</strong></p>\n\n<p></p>\n\n<p><strong>Justification for Single Source Awards IAW FAR 13.106-1</strong></p>\n\n<p><strong>For</strong></p>\n\n<p><strong>Over Micro-Purchase Threshold but Not Exceeding the Simplified Acquisition Threshold</strong></p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>Acquisition Plan Action ID: <u>36C250-26-AP-2650</u></strong></p>\n\n<p></p>\n\n<ol>\n\t<li><strong><u>Contracting Activity</u></strong><strong>:</strong>&nbsp; Department of Veterans Affairs, Network Contracting Office 10 located at 260 E University Avenue, Cincinnati, OH 45219-2356, in support of VISN 10, Cincinnati VA Medical Center (VAMC), 3200 Vine Street, Cincinnati, OH 45220-2213. 2237 #: 539-26-2-043-0148</li>\n</ol>\n\n<p></p>\n\n<p></p>\n\n<ol>\n\t<li><strong>Brief Description of Supplies/ Services required and the intended use/Estimated Amount:</strong>&nbsp; Clinicians in the Speech and Endoscopy clinics at CVAMC operates Government owned high-resolution manometry (HRM) systems to perform diagnostic esophageal motility studies to determine the root cause of symptoms, diagnose esophageal disorders and personalize their approach to manage the care of esophageal patients.</li>\n</ol>\n\n<p></p>\n\n<p>The manometry probe (or catheter) required to operate the HRM system is&nbsp;a thin, flexible tube equipped with sensors, inserted through the nose or mouth into the gastrointestinal tract to measure muscle pressure and coordination.&nbsp;</p>\n\n<p></p>\n\n<p>This new request is for a one-time firm-fixed-price contract to procure replacement manometry probes compatible with the HRM system that are at end of lifecycle.&nbsp; The supplies/services needed are:</p>\n\n<p></p>\n\n<ul>\n\t<li>Manoscan ESO Z CATH X1 &ndash; Mfr. Part #:&nbsp; 3890 &ndash; Quantity of 4 Each</li>\n\t<li>HRM Catheter Extended&nbsp; WARRANTY 1 YEAR &ndash; Mfr. Part #: 80372 &ndash; Quantity of 4 Each</li>\n\t<li>Shipping and Handling (Estimated) &ndash; Quantity of 1 Each</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;</p>\n\n<ol>\n\t<li><strong>Unique characteristics that limit availability to only one source, with the reason no other supplies or services can be used:</strong> The ManoView manometry system is a proprietary platform that requires OEM manufactured ManoScan catheters for operation. These catheters utilize proprietary connectors, hardware interfaces, and system recognition features that are unique to Medtronic equipment.</li>\n</ol>\n\n<p></p>\n\n<p>The HRM system requires OEM-compatible manometry probes to avoid calibration drift, invalid pressure profiles, and adverse impact on clinical decisions. Probes from non‑OEM sources are not validated with this system&rsquo;s firmware and sterile pathway, creating risk to patient safety and data integrity. Medical device accessories must be assessed in context of the parent device; compatibility and risk controls apply. The equipment must meet the following minimum salient characteristics:</p>\n\n<p></p>\n\n<ol>\n\t<li><strong><u>Sensor &amp; Catheter Specifications</u></strong></li>\n</ol>\n\n<p></p>\n\n<p>This section is intentionally left blank.</p>\n\n<p></p>\n\n<ol>\n\t<li><strong><u>Coverage &amp; Mapping Capabilities</u></strong></li>\n</ol>\n\n<p></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp; This section is intentionally left blank.</p>\n\n<p></p>\n\n<ol>\n\t<li><strong><u>Diagnostic Enhancements</u></strong></li>\n</ol>\n\n<p></p>\n\n<p>This section is intentionally left blank.</p>\n\n<p></p>\n\n<ol>\n\t<li><strong><u>Software Functions</u></strong></li>\n</ol>\n\n<p></p>\n\n<p>This section is intentionally left blank.</p>\n\n<p></p>\n\n<ol>\n\t<li><strong><u>Efficiency &amp; Training</u></strong></li>\n</ol>\n\n<p></p>\n\n<p>This section is intentionally left blank.</p>\n\n<p></p>\n\n<ol>\n\t<li><strong>Description of market research conducted and results or statement why it was not conducted:</strong>&nbsp; The CVAMC SPS initiated market research in December 2025 to determine the facility&rsquo;s needs and market availability.&nbsp; The LB OEM provided an informal quote and none of the items were found to be offered on FSS contract.</li>\n</ol>\n\n<p></p>\n\n<p>Additional market queries were conducted by the Contracting Specialist using SBA&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;SBS, SAM.gov, GSA Advantage, VA NAC, and ADDS UP databases.&nbsp; There were</p>\n\n<p>multiple entries found for various types of catheters offered by others in the industry.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;None of those items are compatible with the Government owned HRM equipment at&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; the facility and capable of meeting this requirement.&nbsp; The product NAICS code was &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;not found in the NMR class waiver database.</p>\n\n<p></p>\n\n<p>Direct contact was made with the LB OEM.&nbsp; The OEM confirmed the country of &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;orgin (COO) for the equipment is Vietnam and that pricing is open market.&nbsp; They &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;also identified three (3) SBA SBS verified SDVOSB authorized distributors.</p>\n\n<p></p>\n\n<p>Due to the NMR findings, an SDVOSB, VOSB set-aside is prohibited.&nbsp; The VA and Rule of Two cannot be met. The SBA Rule of Two is obtainable.&nbsp; A small business set-aside solicitation for brand name equipment will be posted to the Governmentwide point of entry (GPE) to obtain fair and reasonable pricing.</p>","origin":"detail"},"contacts":[{"name":"Barbara Robertson","role":"primary","email":"Barbara.Roberton@va.gov","phone":"5138613100"}],"place_of_performance":null,"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"naics_codes":["339112"],"award":{"date":"2026-09-01","amount":"115352.00","number":"36C25026P0866","awardee":{"raw":"COVIDIEN SALES LLC Mansfield MA 02048 USA","name":"COVIDIEN SALES LLC","location":{"zip":"02048","city":{"code":"38225","name":"Mansfield"},"state":{"code":"MA","name":"Massachusetts"},"country":{"code":"USA","name":"UNITED STATES"}}}},"attachments":[{"resource_id":"293c1e20564e46549e336dcdc747056f","name":"36C25026P0866_1.docx","kind":"file","mime_type":".docx","size_bytes":31885,"posted_at":"2026-09-03T18:48:28.803Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/293c1e20564e46549e336dcdc747056f/download","mirrored":false},{"resource_id":"0a74e44d5ad843c68f395ae844d65b13","name":"36C25026Q0636.docx","kind":"file","mime_type":".docx","size_bytes":72567,"posted_at":"2026-06-09T17:01:27.144Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/0a74e44d5ad843c68f395ae844d65b13/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C25026P0866_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C25026P0866_3600_-NONE-_-NONE-/","piid":"36C25026P0866","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"NJCGNFB43XK1","recipient_name":"COVIDIEN SALES LLC","recipient_uei":"NJCGNFB43XK1","recipient_cage":"6VKK4","recipient_city":"MANSFIELD","recipient_state":"MA","sub_name":"Department of Veterans Affairs","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","office_key":"o-36C250","first_action_date":"2026-09-01","last_action_date":"2026-09-01","actions":1,"obligated":"115352.00","current_total_value":"115352.00","potential_total_value":"115352.00","naics":"339112","psc":"6515","extent_competed":"COMPETED UNDER SAP","set_aside":"NO SET ASIDE USED.","offers_received":3,"description":"MANOMETRY PROBES","method":"solicitation","confidence":"high","evidence":["solicitation number 36C25026Q0636 equals the FPDS solicitation identifier","same awarding office 36C250"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C25027Q0014","latest_notice_id":"b13cc87179e947e7b42da2de44a6bde1","title":"J061--541 Electrical Power Distribution Equipment Testing, Inspection, and Maintenance - VAMC Cleveland","solicitation_number":"36C25027Q0014","notice_type":"k","first_type":"k","first_posted":"2026-10-09","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"238210","psc":"J061","set_aside":"SBA","state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C25027Q0123","latest_notice_id":"fb53a332644a4c8fa983bf28c8643d2d","title":"S222--Sources Sought - Hazardous Waste Removal/Disposal Northeast Ohio VA Healthcare System - Cleveland, OH","solicitation_number":"36C25027Q0123","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T18:30:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"562112","psc":"S222","set_aside":null,"state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C25027B0009","latest_notice_id":"85b83d408f1f422885991142c2734b45","title":"Z1DA--FY27 NRM - VISN Base Modernize Nurse Call - 539-23-101","solicitation_number":"36C25027B0009","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"},{"key":"36C25027B0008","latest_notice_id":"5afe716a38494a6f84b1e84205805f86","title":"Z1DA--FY27 NRM - VISN Base Install Roof Equipment Railings - 539-22-206","solicitation_number":"36C25027B0008","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"},{"key":"36C25027B0005","latest_notice_id":"2cb4a6354be04cc89c5d6125945b1892","title":"Z1DA--***FY27 Requirement*** First Floor X Ray - Room CC157 553-CSI-022","solicitation_number":"36C25027B0005","notice_type":"p","first_type":"p","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"MI","county":"26163","county_name":"Wayne County","city":"2622000","city_name":"Detroit","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"}],"similar_open":[{"key":"W911S227U0200","latest_notice_id":"153aef7d00e740188276deb8422a2297","title":"Automated External Defibrillator (AED)","solicitation_number":"W911S227U0200","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T20:15:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:15:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24727Q0119","latest_notice_id":"81776fecabf149c9867d6253acdc2478","title":"Vivarium Tunnel Washer","solicitation_number":"36C24727Q0119","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"339112","psc":"6640","set_aside":null,"state":"GA","county":"13089","county_name":"DeKalb County","city":"1322052","city_name":"Decatur","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C10X27Q0025","latest_notice_id":"8c404062fbbc4212bb93120ad204ee50","title":"6515--NX EQ Microscope, Light, Operating, Hand/Plastic Surgery (VA-27-00017958)","solicitation_number":"36C10X27Q0025","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"}],"similar_open_total":15,"indexable":false}