# EQUIPMENT-REPROCESSING SINK-BATTLE CREEK

Canonical: https://sealedbidder.com/opportunities/36c25026q0476

- Solicitation number: 36C25026Q0476
- Notice type: Combined synopsis and solicitation
- Status: Closed. Deadline was April 20, 2026 at 9:00 AM EDT
- Department: Department of Veterans Affairs
- Contracting office: 250-Network Contract Office 10 (36C250)
- NAICS: 339113 Surgical Appliance and Supplies Manufacturing
- Product or service code: 6515 Medical and Surgical Instruments, Equipment, and Supplies
- Set-aside: Total small business set-aside
- Small business size standard: 800 employees (13 CFR 121.201, NAICS 339113)
- Place of performance: Michigan
- Who can bid, by location: Anywhere in the US. Location does not limit who can bid: a product shipped to the buyer, research at the performer's facility, or work at the contractor's site. A state shown is the delivery point.
- County: Calhoun County (FIPS 26025). https://sealedbidder.com/counties/calhoun-county-mi-26025
- First posted: April 13, 2026
- Last posted: July 9, 2026
- SAM.gov: https://sam.gov/workspace/contract/opp/741d674e6b6a437b87f1f1f318b19d40/view

## Reading this notice

- Kind of notice: Combined synopsis and solicitation. A streamlined commercial-item buy where the notice itself is the solicitation.
- Who may compete: Total small business set-aside. Only small businesses may compete. Small, under NAICS 339113 (surgical appliance and supplies manufacturing), means no more than 800 employees, counted with affiliates.
- Time to respond: Bidders had 7 days from the day the solicitation was posted, April 13, 2026, to the deadline.

## Description

This request is to replace the Endoscopy Reprocessing Sink at the Wyoming Clinic, a CBOC to the Battle Creek VAMC, for the Sterile Processing Service (SPS). The current equipment was original to the building and is noncompliant with VHA Directive 1116(2), and the Association for the Advancement of Medical Instrumentation (AAMI) standards set forth by the Joint Commission, AMMI ST91. This has been deemed a Priority 1 replacement (Mission Critical) for the Gastrointestinal (GI) clinic&rsquo;s reprocessing area within SPS during the recent site visit and audit from the VISN 10 Chief Sterile Processing Officer (CSPO). The C&A requirements do not apply, and a Security Accreditation Package is not required.

Endoscopy Reprocessing Sinks, quantity 1, will require the PureSteel Healthcare Reprocessing Brand, part number PS-97530-HA-03-301810B

Required Specifications:

	Specifically designed for the cleaning of endoscopes

	Overall size 97.5&rdquo; L x 30&rdquo; W, height adjustable

	Three basins measuring 30&rdquo; x 18&rdquo; x 10&rdquo; with telescoping drains

	Ergonomics&mdash;including 45-degree wrist rests one per basin for a total of three), adjustable height by push-button access, and 10&rdquo; gooseneck swivel spout sprayer with ergonomic grip

	Sink Light Hood, one in 4&rsquo; L and one in 2&rsquo; L

	Flat-bottom support shelf that mounts to pegboard backing, 14&rdquo; x 12 x 1.5&rdquo;

	Water resistant programmable timer with alarm function, minutes and seconds, 9.75&rdquo; L x 4.75&rdquo; H x 3&rdquo;D

	Task Halogen Light, 27&rdquo; gooseneck arm with 2X magnifier, water resistant

	BACK Wall Pegboard, height adjustable with the sink, 97.5&rdquo; L x 24&rdquo; H, standard pegs throughout

Additional Accompaniments:

	Volume indicator etching plate, one per basin

	Wall mounted sink facet, 8&rdquo; swing spout and lever handles

	LED Basin lights

	Gallon bottle holder

	Scope Buddy Shelf mount system, 10&rdquo; L x 11&rdquo; D x 5&rdquo; H at the back, 1&rdquo; lip in front

	Stainless steel wire baskets:

		Front facing slant, 12&rdquo; x 12&rdquo; x 8-1/4&rdquo;

		Stainless steel basket size 12&rdquo; x6&rdquo;x 6&rdquo;

	Workflow plates:

		Leak Testing

		Wash

		Rinse

	Three Bay drain kit assembly

## Attachments

- [RFQ 36C25026Q0476_1.docx](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/ca03d595d25e4b45bf5b0d5e4116728e/download)

## Open now in the same industry

20 open in NAICS 339113.

- Sources Sought: Chemical Cannister (PANDTA-26-P-0000036815), due December 17, 2026 at 5:00 PM EST. https://sealedbidder.com/opportunities/pandta26p0000036815
- SOURCES SOUGHT NOTICE FOR HEAD, SHOULDER, AND UPPER-EXTREMITY POSITIONING ACCESSORIES FOR THE MAQUET MEERA 7200 OPERATING TABLE (36C26027Q0130), due November 27, 2026 at 3:00 PM EST. https://sealedbidder.com/opportunities/36c26027q0130
- VALVE,BREATHING APP (N0010427QLA17), due November 27, 2026 at 3:30 PM EST. https://sealedbidder.com/opportunities/n0010427qla17

## Publications

- April 13, 2026: Combined synopsis and solicitation, due April 20, 2026 at 9:00 AM EDT. Notice 417924343fa74504b40ae2b4a2173abe. https://sam.gov/workspace/contract/opp/417924343fa74504b40ae2b4a2173abe/view
- July 9, 2026: Combined synopsis and solicitation, due April 20, 2026 at 9:00 AM EDT. Notice 741d674e6b6a437b87f1f1f318b19d40. https://sam.gov/workspace/contract/opp/741d674e6b6a437b87f1f1f318b19d40/view

## Points of contact

- Percy Johnson, percy.johnson2@a.gov, 6142575534

---
Source: SAM.gov Contract Opportunities bulk extract. Confirm deadlines on SAM.gov before responding. Cite https://sealedbidder.com/opportunities/36c25026q0476.