{"canonical":"https://sealedbidder.com/opportunities/36c25026q0410","key":"36C25026Q0410","url":"https://sealedbidder.com/opportunities/36c25026q0410","title":"6515--Guldmann Patient Ceiling Lifts Motors","solicitation_number":"36C25026Q0410","notice_type":"a","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-04-16T21:00:00Z","first_posted":"2026-04-06","last_posted":"2026-04-27","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"339113","psc":"6515","set_aside":null,"place_state":"OH","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":"Product purchase (PSC 6515)","place_county":"39113","place_county_name":"Montgomery County","place_city":"3921000","place_city_name":"Dayton","winner":"PREMIER MEDICAL DISTRIBUTORS, LLC","award_amount":"764175.00","publications":[{"notice_id":"ba74f82dbb254337894e27ab4a1de9df","title":"6515--Guldmann Patient Ceiling Lift Motors","solicitation_number":"36C25026Q0410","notice_type":"k","base_type":"k","posted":"2026-04-06","posted_at":"2026-04-06T15:47:04.800Z","due_at":"2026-04-16T21:00:00Z","due_date":"2026-04-16","cancelled":false,"archived":true,"archive_date":"2026-06-15","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/ba74f82dbb254337894e27ab4a1de9df/view","enriched":true,"history":[{"index":6,"title":"6515--Guldmann Patient Ceiling Lifts Motors","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-27T13:59:07.623Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"61dbba77b02944e3b9b26703878f3fc8","solicitation_number":"36C25026Q0410","related_opportunity_id":"ba74f82dbb254337894e27ab4a1de9df"},{"index":4,"title":"6515--Guldmann Patient Ceiling Lift Motors","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-06T15:47:04.800Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ba74f82dbb254337894e27ab4a1de9df","solicitation_number":"36C25026Q0410"}]},{"notice_id":"61dbba77b02944e3b9b26703878f3fc8","title":"6515--Guldmann Patient Ceiling Lifts Motors","solicitation_number":"36C25026Q0410","notice_type":"a","base_type":"k","posted":"2026-04-27","posted_at":"2026-04-27T13:59:07.623Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-06-26","removed_at":null,"award_number":"36C25026P0614","awardee_name":"PREMIER MEDICAL DISTRIBUTORS, LLC","amount":"764175.00","link_sam":"https://sam.gov/workspace/contract/opp/61dbba77b02944e3b9b26703878f3fc8/view","enriched":true,"history":[{"index":6,"title":"6515--Guldmann Patient Ceiling Lifts Motors","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-27T13:59:07.623Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"61dbba77b02944e3b9b26703878f3fc8","solicitation_number":"36C25026Q0410","related_opportunity_id":"ba74f82dbb254337894e27ab4a1de9df"},{"index":4,"title":"6515--Guldmann Patient Ceiling Lift Motors","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-06T15:47:04.800Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ba74f82dbb254337894e27ab4a1de9df","solicitation_number":"36C25026Q0410"}]}],"latest_notice_id":"61dbba77b02944e3b9b26703878f3fc8","first_type":"k","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-04-06","posted_at":"2026-04-06T15:47:04.800Z","created_at":"2026-04-06T15:47:02.081Z","modified_at":"2026-06-16T03:55:46.102Z","response_deadline":{"raw":"2026-04-16T17:00:00-04:00","utc":"2026-04-16T21:00:00Z","date":"2026-04-16","time":"17:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/ba74f82dbb254337894e27ab4a1de9df/view"},"naics":{"codes":["339113"],"primary":"339113"},"title":"6515--Guldmann Patient Ceiling Lift Motors","agency":{"office":{"code":"36C250","name":"250-NETWORK CONTRACT OFFICE 10 (36C250)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"organization_id":"100167099","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-06-15","archive_type":"auto_custom"},"history":[{"index":6,"title":"6515--Guldmann Patient Ceiling Lifts Motors","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-27T13:59:07.623Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"61dbba77b02944e3b9b26703878f3fc8","solicitation_number":"36C25026Q0410","related_opportunity_id":"ba74f82dbb254337894e27ab4a1de9df"},{"index":4,"title":"6515--Guldmann Patient Ceiling Lift Motors","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-06T15:47:04.800Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ba74f82dbb254337894e27ab4a1de9df","solicitation_number":"36C25026Q0410"}],"contacts":[{"name":"Jeffrey Rozema","role":"primary","email":"jeffrey.rozema@va.gov","phone":"269-966-5600","title":"Contracting Officer"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"ba74f82dbb254337894e27ab4a1de9df","lineage_id":"ba74f82dbb254337894e27ab4a1de9df","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-08T03:19:07.027834001Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"d0f323316947b3362737c25ab98aa5ad627f42f7b8852180e2967f4713483ae6","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-08T03:19:07.027834001Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"Combined Synopsis-Solicitation for Commercial Products and Commercial Services\nDayton VA Medical Center\nGuldmann Patient Ceiling Lift Motors \n\nEffective Date:  01/15/2026\nRevision: 03\nDescription\nThis is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format Revolutionary FAR Overhaul (RFO) in Federal Acquisition Regulation (FAR) subpart 12.202,  Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services,  as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued.\n\nThis solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-01 effective March 13, 2026.\n\nThis solicitation is not set-aside for small business.\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339113   Surgical Appliance and Supplies Manufacturing, with a small business size standard of 800 employees.\nThe FSC/PSC is 6515   Medical and Surgical Instruments, Equipment, and Supplies.\n\nThe Department of Veterans Affairs, Regional Procurement Office Central, Network Contracting Office 10, 5500 Armstrong Road, Battle Creek, MI 49037 is seeking to purchase Guldmann GH3+ patient ceiling lift motors including installation for the Dayton VA Medical Center located at 4100 West 3rd Street, Dayton, OH 45428.\n\nAll interested and qualified companies shall provide quotations for the following:\n\nSupplies/Services\n\nLine Item\nDescription\nQuantity\nUnit of Measure\nUnit Price\nTotal Price\n0001\nGuldmann GH3+ 605lbs SWL Hoist w/Scale CLM and Hanger Bar\n127\nEA\n\n\n0002\nGuldmann GH3+ Twin 1100lbs SWL Hoist w/Scale & Hanger Bar\n1\nEA\n\n\n0003\nCertified Installation - Hoist Replacement and Weight Test (includes Twin Swap)\n128\nEA\n\n\nStatement of Work\nBackground\nDayton VAMC is soliciting quotes for a contractor to provide all labor and materials to replace 128 end of life ceiling lift systems. Various lift weight capacities are required. New units to match existing lifts in the hospital to avoid misuse of unfamiliar equipment and allow for patient transfer between different lifts using a mutually compatible sling.\nScope\nContractor will provide equipment and services listed in this statement of work.\nThe Contractor will provide all necessary supplies, materials, equipment, qualified personnel, supervision, management, and transportation. \nAll work is to be performed in accordance with the guidelines established by Federal, State, and local ordinances and The Joint Commission. The Contractor s work procedures and quality control procedures shall conform to these guidelines.\nSpecific Tasks  \nReplacement of 128 lift motors as detailed in Tables A-B. All lifts to undergo Certified Installation - Hoist Replacement and Weight Testing.\nTable A. GH3+ 605lbs SWL Hoist w/Scale & Hanger Bar\nCLC   Main Tower\nQuantity: 38\n5D126-330\n5C113-330\n5C117-330\n5C12-330\n5D101-330\n5D104-330\n5D117-330\n5C118-330\n5C119-330\n5C127-330 (2x)\n\n5C127-330\n5C128-330\n5C129-330\n5C130-330\n5C133-330\n5C137-330\n5C138-330\n5C141-330\n5C142-330\n5C143-330\n5C144-330\n5C145-330\n5C147-330\n5D107-330\n5D108-330\n5D109-330\n5D116-330\n5D118-330\n5D122-330\n5D140-330\n5D130-330\n5D131-330\n5D132-330\n5D133-330\n5D134-330\n5D136-330\n5D138-330\n\nCLC Building\nQuantity: 47\n1A174-320\n1E124-320\n1A110-320\n1A113-320\n1A118-320\n1A120-320\n1A122-320\n1A126-320\n1A129-320 (2x)\n1A133-320\n1A134-320\n1D166-320\n\n1A137-320\n1A141-320\n1A159-320\n1A162-320\n1A163-320\n1A166-320\n1A167-320\n1A171-320\n1A176-320\n1B120-320\n1B137-320\n1B138-320\n1B141-320\n1B159-320\n1B162-320\n1B166-320\n1B170-320\n1B174-320\n1B175-320\n1C111-320\n1C115-320\n1C117-320\n1C118-320\n1C120-320\n1C121-320\n1C122-320\n1C123-320\n1C124-320\n1C136-320\n1C138-320\n1C139-320\n1C140-320\n1C141-320\n1C142-320\n\nDental Clinic\nQuantity: 1\n2B132-330\n\n\n\n\n Emergency Department\nQuantity: 1\n1G105-310\n\n\n\n\n GI Clinic\nQuantity: 1\nGI125-330\n\n\n\n\n MED 1 Unit\nQuantity: 20\n4C132-330\n4C145-330\n4C111-330\n4C112-330\n4C116-330\n\n4C118-330\n4C122-330\n4C130-330\n4C131-330\n4C134-330\n4C136-330\n4C139-330\n4C141A-330\n4C146-330\n4C147-330\n4C148-330\n4C150-330\n4C152-330\n4C153-330\n4C154-330\n Radiation Oncology\nQuantity: 2\n1-322\n\n30-322\n\n\n Radiology\nQuantity: 3\n1B114-330\n\n1B115-330\n1B123-330\n\n Renal Clinic\nQuantity: 1\n3C159-330\n\n\n\n\n SAM Unit\nQuantity: 7\n3D111-330\n3D134-330\n\n3D137-330\n3D119-330\n3D121-330\n3D133-330\n3D142-330\nSimulation Center\nQuantity: 6\n114-315\n116-315\n118-315\n119-315\n120-315\n\n124-315\n\n\nTable B. GH3+ Twin 1100lbs SWL Hoist w/Scale & Hanger Bar\nMorgue\nQuantity: 1\n2E142-310\n\n\n\nDisposal of old systems being removed from service.\nProvide education and training:\nOne session of training for biomedical engineering staff.\nTraining must include each new type of equipment and sling used in an area.\nPerform weight and function testing for each lift after installation in compliance with the VHA checklist required by Patient Safety Alert AL14-07. Each checklist shall be provided to Contracting Officer Representative within 7 days of installation along with any checklist required by the manufacturer. Any changes in inspection requirements during the period of installation will be communicated to the Contractor immediately. \nProvide the below deliverables.\nElectronic copies of the user manuals and repair manuals for each different model of lift installed under this order or contract at no additional cost to the government\nThis is a brand-name only solicitation for Guldmann GH3+ patient ceiling lifts/lift systems, which include equipment and installation for the Dayton VAMC.\nSystem Specifications:\nEach handset must have an integrated scale for patient weight built into the handset controller without compromising bed to hangar bar height and the ability to be safely secured to the lift when not in use.\nThe lift hand control must be attached to the lift hanger bar to avoid it from coming dislodged when not in use, potentially causing patient and/or healthcare worker injury.\nA wide range of mounting options (such as a lift system which can offer a combined wall and ceiling mount configuration) to accommodate the various patient room environments which exist within our facility. \nThe ability for full XY coverage in all patient care rooms, including therapy areas and maximum coverage in patient bathrooms.\nOperation of the system must allow for a minimum of 24  lifting height for transfer of patient from wheelchair/exam table/toilet, as well as adequate lifting height for the turning and repositioning of the patient on the exam table or lowering height for fall recovery off the floor. \nThe hanger bars must be able to be changed out by the medical center s staff without the assistance of contractors, vendors, or special tools. \nHangar bars must have 2- or 4-point hooks with secondary security measures, such as a steel or metal clip or double hook.\nLift systems must have software that allows for automatic tracking of preventative maintenance requirements as outlined in the National Patient Safety Alert AL 10-07 (2014).  Tracking data must include the following: when service is next due, number of weighings, total lifetime lifts, dates of last timing belt and battery change and number of lifts since reset.\nTechnology that allows lift data to be viewed in Excel such as day & time of lifts, how long transfers are taking, height of the transfers, & weight of the transfers \nEmergency stopping device.\nThe emergency lowering feature must be operable without the use of any additional tools and the lift motor must be able to be reset by staff without any additional tools, allowing immediate use of the lift after activation of the emergency stop/lowering feature, without the need to call engineering or the manufacturer to reset the lift.\nSafety device that stops the motor lifting when batteries are low.\nLifting speed options up to 60mm/sec must be available.\nPlug and play technology must be employed to facilitate ease and reduced costs in system repairs and maintenance, one person replacement on current rail system.\nThe hoist must maintain a continuous charge on the rail. \nOperation of the system must be smooth with no fast or jerky starts and stops.\nCeiling lifts shall meet all Underwriters Laboratory requirements, life safety codes, national electric codes, fire safety codes, and all other applicable federal, state and local codes. Appropriate documentation should be provided.\nCeiling lifts shall comply with ISO 10535 (Hoists for the transfer of disabled persons   Requirements and test methods).\nCeiling lifts must include a 2-point hanger bar, suitable and allowable for use with the full range of loop-based Guldmann slings, with 2 hooks facing different directions on each end of the bar and without easily breakable parts such as rubber flaps.\nThe lifts shall be mounted (using ceiling, wall, or floor support as determined by building structure and room covering layout needs) to provide lifting capability for the maximum area possible within each room which means wall to wall   not just over the bed.\nLifts must be capable of picking patients up off the floor.\nLifts must not beep or flash during normal operation.\nLifts must be able to lift a full-capacity load at least 21 times on a full, new battery charge.\nCeiling lift motors shall be capable of lifting a weight no less than as specified in the replacement and installation tables.\nNew lifts shall accept generic type replacement batteries without voiding any warranties.\nMotors shall be GFCI protected.\nCeiling lifts  vertical motion must be motorized.\nCeiling lifts that connect from one room to another must be designed so that they cannot come off the rail system while in use, and the connecting rail and the systems in both rooms must all hold at least as much weight as the lift motor.\nCeiling lifts must recharge automatically, by recharging at any location on the rail without employee action.\nCeiling lifts must include safeguards to prevent patients from being trapped or hurt, such as emergency stop buttons and emergency lowering devices in case of power failure. Use of emergency lowering devices must not require tools or ladders.\nPerformance Monitoring\nHealthcare Technology Management (HTM) will complete incoming inspection of the delivered units per manufacturer guidelines. Project COR and Patient Safe Handling and Mobility will monitor the project and coordinate installations with contractor personnel. \nSecurity Requirements\nThe C&A requirements do not apply, and a Security Accreditation Package is not required. \nGovernment-Furnished Equipment (GFE)/Government-Furnished Information (GFI)  \nN/A\nOther Pertinent Information or Special Considerations \nAll work shall be in direct compliance in accordance with the VHA Safe Patient Handling and Mobility Directive 1611 (7/11/2023), and National Patient Safety Alert AL 14-07 (2014). \nEquipment and supplies must not be shipped before designs are approved and contractor has approval to install. Dayton VAMC cannot store uninstalled equipment for a significant length of time.\nAll contractors must pass VA adjudication and credentialing process.\nAll employees and subcontractors must wear a visible name and company identification when onsite. When more than one person is onsite performing work under this contract, one must be designated as a supervisor and must be fully responsible for the work to be performed.\nContractor personnel must conduct their work so as not to interfere with the normal functioning of the facility and will stop work if asked by Dayton VAMC personnel. Hours of work will need to be limited to daytime on units where patients sleep or to nighttime or weekends in areas where patients would be exposed by daytime work.\nThe Contractor shall take all precautions necessary to protect the lives and health of occupants of the building.\nThe Contractor must follow procedures required by Dayton VAMC Infection Control personnel and the construction safety committee, to include any required dust control specified in the Infection Control Risk Assessment.\nThe Contractor must state what efforts will be made to minimize noise during installation of equipment.\nThe Contractor shall immediately correct any fire and safety deficiencies caused by his personnel. If the contractor fails or refuses to correct deficiencies promptly, the Contracting Officer may issue an order stopping all or any part of the work and may hold the contractor in default of the contract.\nThe Contractor shall comply with applicable Federal, State, and local safety and fire regulations and codes which are in effect at the beginning of the contract period. The contractor shall keep abreast of any changes in these regulations and codes applicable to the contract. The contractor shall keep abreast of any changes in these regulations and codes applicable to the contract.\nAll material and equipment will be removed from the facility or stored properly at the end of each workday and secured during the workday in the areas specified by the Contracting Officer s Technical Representative.\nThe Contractor is responsible for supplying, completing, and submitting all reports required or requested by Federal, State, or local ordinances which pertain to any duties contained in the contract.\nThe Contractor will be required to furnish the Dayton VAMC with material safety data sheets for all chemicals used during installation. This information is required by the VA for emergency treatment in the event of ingestion of and/or contact with the material by humans and is required by OSHA regulations.\nThe Contractor s onsite lead installer must attend a Dayton VAMC construction safety orientation and supply job hazard analyses as required by Construction Safety Officer to show how hazards to Contractor and VHSO personnel are being minimized.\nAll Contractor personnel must have OSHA 10-hour construction safety training cards.\nThe Contractor s personnel shall follow applicable policies of the Dayton VAMC, to include policies concerning fire and disaster preparedness programs.\nThe contractor shall furnish at his own expense all labor, materials, machinery, and appliances which may be necessary or appropriate in the performance of this contract.\nAll accumulated rubbish is to be collected and placed in the dumpster provided by the Government. Large quantities need to be disposed of in ways that do not overload the dumpsters.\nThe contractor must have visited the sites and assessed the structure of each ceiling lift location to ensure safe installation of the equipment and shall supply the installation plans to the Dayton VAMC HTM Service, who must accept them before installation.\nCeiling lift installations shall comply with NFPA 13 for fire sprinklers and with NFPA 99 and NFPA 70 for proper grounding and bonding and access to electrical and safety systems.\nThe contractor should not require movement of any lights, sprinklers, televisions, or other fixtures in order to install ceiling lifts. If movement of preexisting fixtures is unavoidable, the contractor must include such notice when the bid is submitted.\nWall mounted lifts are acceptable in the place of ceiling mounts where they are more effective or cause less risk to install.\nCeiling lifts must not add obstacles or impair any normal operations in patient care rooms.\nIt is permissible to raise the lifting height or extend the range of a lift system that is being replaced, so long as designs are approved by the facility in advance and all obstacles are avoided to avoid interference with the operation of curtains, ventilation, or other moving or ceiling mounted items.\nAll installations that affect existing areas and electrical work shall be coordinated with Dayton VAMC HTM service.\nThe contractor will install all necessary mounts, braces, and any other components needed for full lift function and safety.\nChanges to Statement of Work: Any changes to this SOW shall be authorized and approved only through written correspondence from the CO. A copy of each change will be kept in a project folder along with all other products of the project. Costs incurred by the contractor through the actions of parties other than the CO shall be borne by the contractor.\nReporting Requirements: The VHA checklist and any manufacturer s checklist are the sole report and must be provided to the COR within 1 week of installation. Lift installation is not considered complete and cannot be paid for until the checklist is complete and provided to the COR.\nRisk Control\nContractor will be installing units in an active healthcare environment and will be required to comply with VAMC required above ceiling work permits, infection control procedures, and all OSHA requirements.\n\nPlace of Performance\n\nDayton VAMC \n4100 W. Third Street\nDayton OH 45428\nPeriod of Performance \nAll work shall be completed and in compliance within 180 calendar days from the contractor s receipt of the order. If for any reason any deliverable cannot be delivered within the scheduled time frame, the contractor is required to explain why in writing to the CO, including a firm commitment of when the work shall be completed. This notice to the CO shall cite the reasons for the delay, and the impact on the overall project. The CO will then review the facts and issue a response, in accordance with applicable regulations.\nDelivery Schedule \nDelivery to take place in batches with batch size to be determined by Dayton VAMC to prevent storage demands exceeding the capacity of Dayton VAMC s warehouse space.\n\nDelivery FOB Destination and installation no later than 180 days after receipt of order (ARO).\nPlace of Performance/Place of Delivery\nAddress:\nDepartment of Veterans Affairs\nDayton VA Medical Center\n4100 West 3rd Street\nDayton, OH \nPostal Code:\n45428\nCountry:\nUNITED STATES\n\nAll quoters shall submit the following: \n\nPrice quote.\nDocumentation from the OEM, Guldmann, Inc., indicating your company is an authorized supplier and installer for Guldmann lifts.\n\nAll quotes shall be sent to the Contracting Officer, Jeffrey Rozema, via email at jeffrey.rozema@va.gov.\n\nAward will be based on the lowest price for the exact items listed above.\n\n\nOfferors must complete annual representations and certifications electronically via the System for Award Management (SAM) website located at https://sam.gov/.\n\nTo facilitate the award process, all quotes must include a statement regarding the terms and conditions herein as follows:\n\"The terms and conditions in the solicitation are acceptable to be included in the award document without modification, deletion, or addition.\"\nOR\n\"The terms and conditions in the solicitation are acceptable to be included in the award document with the exception, deletion, or addition of the following:\"\n Quoters shall list exception(s) and rationale for the exception(s), if any.\n\nSubmission of your response shall be received not later than 5:00 PM Eastern Time, Thursday, April 16, 2026, by email at jeffrey.rozema@va.gov.\n\nLate submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f).  \n\nAny questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below. \nPoint of Contact\nPoint of contact for this solicitation is Jeffrey Rozema, Contracting Officer, email: jeffrey.rozema@va.gov.","text":"Combined Synopsis-Solicitation for Commercial Products and Commercial Services\nDayton VA Medical Center\nGuldmann Patient Ceiling Lift Motors\n\nEffective Date: 01/15/2026\nRevision: 03\nDescription\nThis is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format Revolutionary FAR Overhaul (RFO) in Federal Acquisition Regulation (FAR) subpart 12.202, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued.\n\nThis solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-01 effective March 13, 2026.\n\nThis solicitation is not set-aside for small business.\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339113 Surgical Appliance and Supplies Manufacturing, with a small business size standard of 800 employees.\nThe FSC/PSC is 6515 Medical and Surgical Instruments, Equipment, and Supplies.\n\nThe Department of Veterans Affairs, Regional Procurement Office Central, Network Contracting Office 10, 5500 Armstrong Road, Battle Creek, MI 49037 is seeking to purchase Guldmann GH3+ patient ceiling lift motors including installation for the Dayton VA Medical Center located at 4100 West 3rd Street, Dayton, OH 45428.\n\nAll interested and qualified companies shall provide quotations for the following:\n\nSupplies/Services\n\nLine Item\nDescription\nQuantity\nUnit of Measure\nUnit Price\nTotal Price\n0001\nGuldmann GH3+ 605lbs SWL Hoist w/Scale CLM and Hanger Bar\n127\nEA\n\n0002\nGuldmann GH3+ Twin 1100lbs SWL Hoist w/Scale & Hanger Bar\n1\nEA\n\n0003\nCertified Installation - Hoist Replacement and Weight Test (includes Twin Swap)\n128\nEA\n\nStatement of Work\nBackground\nDayton VAMC is soliciting quotes for a contractor to provide all labor and materials to replace 128 end of life ceiling lift systems. Various lift weight capacities are required. New units to match existing lifts in the hospital to avoid misuse of unfamiliar equipment and allow for patient transfer between different lifts using a mutually compatible sling.\nScope\nContractor will provide equipment and services listed in this statement of work.\nThe Contractor will provide all necessary supplies, materials, equipment, qualified personnel, supervision, management, and transportation.\nAll work is to be performed in accordance with the guidelines established by Federal, State, and local ordinances and The Joint Commission. The Contractor s work procedures and quality control procedures shall conform to these guidelines.\nSpecific Tasks\nReplacement of 128 lift motors as detailed in Tables A-B. All lifts to undergo Certified Installation - Hoist Replacement and Weight Testing.\nTable A. GH3+ 605lbs SWL Hoist w/Scale & Hanger Bar\nCLC Main Tower\nQuantity: 38\n5D126-330\n5C113-330\n5C117-330\n5C12-330\n5D101-330\n5D104-330\n5D117-330\n5C118-330\n5C119-330\n5C127-330 (2x)\n\n5C127-330\n5C128-330\n5C129-330\n5C130-330\n5C133-330\n5C137-330\n5C138-330\n5C141-330\n5C142-330\n5C143-330\n5C144-330\n5C145-330\n5C147-330\n5D107-330\n5D108-330\n5D109-330\n5D116-330\n5D118-330\n5D122-330\n5D140-330\n5D130-330\n5D131-330\n5D132-330\n5D133-330\n5D134-330\n5D136-330\n5D138-330\n\nCLC Building\nQuantity: 47\n1A174-320\n1E124-320\n1A110-320\n1A113-320\n1A118-320\n1A120-320\n1A122-320\n1A126-320\n1A129-320 (2x)\n1A133-320\n1A134-320\n1D166-320\n\n1A137-320\n1A141-320\n1A159-320\n1A162-320\n1A163-320\n1A166-320\n1A167-320\n1A171-320\n1A176-320\n1B120-320\n1B137-320\n1B138-320\n1B141-320\n1B159-320\n1B162-320\n1B166-320\n1B170-320\n1B174-320\n1B175-320\n1C111-320\n1C115-320\n1C117-320\n1C118-320\n1C120-320\n1C121-320\n1C122-320\n1C123-320\n1C124-320\n1C136-320\n1C138-320\n1C139-320\n1C140-320\n1C141-320\n1C142-320\n\nDental Clinic\nQuantity: 1\n2B132-330\n\nEmergency Department\nQuantity: 1\n1G105-310\n\nGI Clinic\nQuantity: 1\nGI125-330\n\nMED 1 Unit\nQuantity: 20\n4C132-330\n4C145-330\n4C111-330\n4C112-330\n4C116-330\n\n4C118-330\n4C122-330\n4C130-330\n4C131-330\n4C134-330\n4C136-330\n4C139-330\n4C141A-330\n4C146-330\n4C147-330\n4C148-330\n4C150-330\n4C152-330\n4C153-330\n4C154-330\nRadiation Oncology\nQuantity: 2\n1-322\n\n30-322\n\nRadiology\nQuantity: 3\n1B114-330\n\n1B115-330\n1B123-330\n\nRenal Clinic\nQuantity: 1\n3C159-330\n\nSAM Unit\nQuantity: 7\n3D111-330\n3D134-330\n\n3D137-330\n3D119-330\n3D121-330\n3D133-330\n3D142-330\nSimulation Center\nQuantity: 6\n114-315\n116-315\n118-315\n119-315\n120-315\n\n124-315\n\nTable B. GH3+ Twin 1100lbs SWL Hoist w/Scale & Hanger Bar\nMorgue\nQuantity: 1\n2E142-310\n\nDisposal of old systems being removed from service.\nProvide education and training:\nOne session of training for biomedical engineering staff.\nTraining must include each new type of equipment and sling used in an area.\nPerform weight and function testing for each lift after installation in compliance with the VHA checklist required by Patient Safety Alert AL14-07. Each checklist shall be provided to Contracting Officer Representative within 7 days of installation along with any checklist required by the manufacturer. Any changes in inspection requirements during the period of installation will be communicated to the Contractor immediately.\nProvide the below deliverables.\nElectronic copies of the user manuals and repair manuals for each different model of lift installed under this order or contract at no additional cost to the government\nThis is a brand-name only solicitation for Guldmann GH3+ patient ceiling lifts/lift systems, which include equipment and installation for the Dayton VAMC.\nSystem Specifications:\nEach handset must have an integrated scale for patient weight built into the handset controller without compromising bed to hangar bar height and the ability to be safely secured to the lift when not in use.\nThe lift hand control must be attached to the lift hanger bar to avoid it from coming dislodged when not in use, potentially causing patient and/or healthcare worker injury.\nA wide range of mounting options (such as a lift system which can offer a combined wall and ceiling mount configuration) to accommodate the various patient room environments which exist within our facility.\nThe ability for full XY coverage in all patient care rooms, including therapy areas and maximum coverage in patient bathrooms.\nOperation of the system must allow for a minimum of 24 lifting height for transfer of patient from wheelchair/exam table/toilet, as well as adequate lifting height for the turning and repositioning of the patient on the exam table or lowering height for fall recovery off the floor.\nThe hanger bars must be able to be changed out by the medical center s staff without the assistance of contractors, vendors, or special tools.\nHangar bars must have 2- or 4-point hooks with secondary security measures, such as a steel or metal clip or double hook.\nLift systems must have software that allows for automatic tracking of preventative maintenance requirements as outlined in the National Patient Safety Alert AL 10-07 (2014). Tracking data must include the following: when service is next due, number of weighings, total lifetime lifts, dates of last timing belt and battery change and number of lifts since reset.\nTechnology that allows lift data to be viewed in Excel such as day & time of lifts, how long transfers are taking, height of the transfers, & weight of the transfers\nEmergency stopping device.\nThe emergency lowering feature must be operable without the use of any additional tools and the lift motor must be able to be reset by staff without any additional tools, allowing immediate use of the lift after activation of the emergency stop/lowering feature, without the need to call engineering or the manufacturer to reset the lift.\nSafety device that stops the motor lifting when batteries are low.\nLifting speed options up to 60mm/sec must be available.\nPlug and play technology must be employed to facilitate ease and reduced costs in system repairs and maintenance, one person replacement on current rail system.\nThe hoist must maintain a continuous charge on the rail.\nOperation of the system must be smooth with no fast or jerky starts and stops.\nCeiling lifts shall meet all Underwriters Laboratory requirements, life safety codes, national electric codes, fire safety codes, and all other applicable federal, state and local codes. Appropriate documentation should be provided.\nCeiling lifts shall comply with ISO 10535 (Hoists for the transfer of disabled persons Requirements and test methods).\nCeiling lifts must include a 2-point hanger bar, suitable and allowable for use with the full range of loop-based Guldmann slings, with 2 hooks facing different directions on each end of the bar and without easily breakable parts such as rubber flaps.\nThe lifts shall be mounted (using ceiling, wall, or floor support as determined by building structure and room covering layout needs) to provide lifting capability for the maximum area possible within each room which means wall to wall not just over the bed.\nLifts must be capable of picking patients up off the floor.\nLifts must not beep or flash during normal operation.\nLifts must be able to lift a full-capacity load at least 21 times on a full, new battery charge.\nCeiling lift motors shall be capable of lifting a weight no less than as specified in the replacement and installation tables.\nNew lifts shall accept generic type replacement batteries without voiding any warranties.\nMotors shall be GFCI protected.\nCeiling lifts vertical motion must be motorized.\nCeiling lifts that connect from one room to another must be designed so that they cannot come off the rail system while in use, and the connecting rail and the systems in both rooms must all hold at least as much weight as the lift motor.\nCeiling lifts must recharge automatically, by recharging at any location on the rail without employee action.\nCeiling lifts must include safeguards to prevent patients from being trapped or hurt, such as emergency stop buttons and emergency lowering devices in case of power failure. Use of emergency lowering devices must not require tools or ladders.\nPerformance Monitoring\nHealthcare Technology Management (HTM) will complete incoming inspection of the delivered units per manufacturer guidelines. Project COR and Patient Safe Handling and Mobility will monitor the project and coordinate installations with contractor personnel.\nSecurity Requirements\nThe C&A requirements do not apply, and a Security Accreditation Package is not required.\nGovernment-Furnished Equipment (GFE)/Government-Furnished Information (GFI)\nN/A\nOther Pertinent Information or Special Considerations\nAll work shall be in direct compliance in accordance with the VHA Safe Patient Handling and Mobility Directive 1611 (7/11/2023), and National Patient Safety Alert AL 14-07 (2014).\nEquipment and supplies must not be shipped before designs are approved and contractor has approval to install. Dayton VAMC cannot store uninstalled equipment for a significant length of time.\nAll contractors must pass VA adjudication and credentialing process.\nAll employees and subcontractors must wear a visible name and company identification when onsite. When more than one person is onsite performing work under this contract, one must be designated as a supervisor and must be fully responsible for the work to be performed.\nContractor personnel must conduct their work so as not to interfere with the normal functioning of the facility and will stop work if asked by Dayton VAMC personnel. Hours of work will need to be limited to daytime on units where patients sleep or to nighttime or weekends in areas where patients would be exposed by daytime work.\nThe Contractor shall take all precautions necessary to protect the lives and health of occupants of the building.\nThe Contractor must follow procedures required by Dayton VAMC Infection Control personnel and the construction safety committee, to include any required dust control specified in the Infection Control Risk Assessment.\nThe Contractor must state what efforts will be made to minimize noise during installation of equipment.\nThe Contractor shall immediately correct any fire and safety deficiencies caused by his personnel. If the contractor fails or refuses to correct deficiencies promptly, the Contracting Officer may issue an order stopping all or any part of the work and may hold the contractor in default of the contract.\nThe Contractor shall comply with applicable Federal, State, and local safety and fire regulations and codes which are in effect at the beginning of the contract period. The contractor shall keep abreast of any changes in these regulations and codes applicable to the contract. The contractor shall keep abreast of any changes in these regulations and codes applicable to the contract.\nAll material and equipment will be removed from the facility or stored properly at the end of each workday and secured during the workday in the areas specified by the Contracting Officer s Technical Representative.\nThe Contractor is responsible for supplying, completing, and submitting all reports required or requested by Federal, State, or local ordinances which pertain to any duties contained in the contract.\nThe Contractor will be required to furnish the Dayton VAMC with material safety data sheets for all chemicals used during installation. This information is required by the VA for emergency treatment in the event of ingestion of and/or contact with the material by humans and is required by OSHA regulations.\nThe Contractor s onsite lead installer must attend a Dayton VAMC construction safety orientation and supply job hazard analyses as required by Construction Safety Officer to show how hazards to Contractor and VHSO personnel are being minimized.\nAll Contractor personnel must have OSHA 10-hour construction safety training cards.\nThe Contractor s personnel shall follow applicable policies of the Dayton VAMC, to include policies concerning fire and disaster preparedness programs.\nThe contractor shall furnish at his own expense all labor, materials, machinery, and appliances which may be necessary or appropriate in the performance of this contract.\nAll accumulated rubbish is to be collected and placed in the dumpster provided by the Government. Large quantities need to be disposed of in ways that do not overload the dumpsters.\nThe contractor must have visited the sites and assessed the structure of each ceiling lift location to ensure safe installation of the equipment and shall supply the installation plans to the Dayton VAMC HTM Service, who must accept them before installation.\nCeiling lift installations shall comply with NFPA 13 for fire sprinklers and with NFPA 99 and NFPA 70 for proper grounding and bonding and access to electrical and safety systems.\nThe contractor should not require movement of any lights, sprinklers, televisions, or other fixtures in order to install ceiling lifts. If movement of preexisting fixtures is unavoidable, the contractor must include such notice when the bid is submitted.\nWall mounted lifts are acceptable in the place of ceiling mounts where they are more effective or cause less risk to install.\nCeiling lifts must not add obstacles or impair any normal operations in patient care rooms.\nIt is permissible to raise the lifting height or extend the range of a lift system that is being replaced, so long as designs are approved by the facility in advance and all obstacles are avoided to avoid interference with the operation of curtains, ventilation, or other moving or ceiling mounted items.\nAll installations that affect existing areas and electrical work shall be coordinated with Dayton VAMC HTM service.\nThe contractor will install all necessary mounts, braces, and any other components needed for full lift function and safety.\nChanges to Statement of Work: Any changes to this SOW shall be authorized and approved only through written correspondence from the CO. A copy of each change will be kept in a project folder along with all other products of the project. Costs incurred by the contractor through the actions of parties other than the CO shall be borne by the contractor.\nReporting Requirements: The VHA checklist and any manufacturer s checklist are the sole report and must be provided to the COR within 1 week of installation. Lift installation is not considered complete and cannot be paid for until the checklist is complete and provided to the COR.\nRisk Control\nContractor will be installing units in an active healthcare environment and will be required to comply with VAMC required above ceiling work permits, infection control procedures, and all OSHA requirements.\n\nPlace of Performance\n\nDayton VAMC\n4100 W. Third Street\nDayton OH 45428\nPeriod of Performance\nAll work shall be completed and in compliance within 180 calendar days from the contractor s receipt of the order. If for any reason any deliverable cannot be delivered within the scheduled time frame, the contractor is required to explain why in writing to the CO, including a firm commitment of when the work shall be completed. This notice to the CO shall cite the reasons for the delay, and the impact on the overall project. The CO will then review the facts and issue a response, in accordance with applicable regulations.\nDelivery Schedule\nDelivery to take place in batches with batch size to be determined by Dayton VAMC to prevent storage demands exceeding the capacity of Dayton VAMC s warehouse space.\n\nDelivery FOB Destination and installation no later than 180 days after receipt of order (ARO).\nPlace of Performance/Place of Delivery\nAddress:\nDepartment of Veterans Affairs\nDayton VA Medical Center\n4100 West 3rd Street\nDayton, OH\nPostal Code:\n45428\nCountry:\nUNITED STATES\n\nAll quoters shall submit the following:\n\nPrice quote.\nDocumentation from the OEM, Guldmann, Inc., indicating your company is an authorized supplier and installer for Guldmann lifts.\n\nAll quotes shall be sent to the Contracting Officer, Jeffrey Rozema, via email at jeffrey.rozema@va.gov.\n\nAward will be based on the lowest price for the exact items listed above.\n\nOfferors must complete annual representations and certifications electronically via the System for Award Management (SAM) website located at https://sam.gov/.\n\nTo facilitate the award process, all quotes must include a statement regarding the terms and conditions herein as follows:\n\"The terms and conditions in the solicitation are acceptable to be included in the award document without modification, deletion, or addition.\"\nOR\n\"The terms and conditions in the solicitation are acceptable to be included in the award document with the exception, deletion, or addition of the following:\"\nQuoters shall list exception(s) and rationale for the exception(s), if any.\n\nSubmission of your response shall be received not later than 5:00 PM Eastern Time, Thursday, April 16, 2026, by email at jeffrey.rozema@va.gov.\n\nLate submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f).\n\nAny questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below.\nPoint of Contact\nPoint of contact for this solicitation is Jeffrey Rozema, Contracting Officer, email: jeffrey.rozema@va.gov.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C25026Q0410","place_of_performance":{"zip":"45428","city":{"code":"21000","name":"Dayton"},"state":{"code":"OH","name":"Ohio"},"street":"Department of Veterans Affairs Dayton VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"4100 West 3rd Street"},"product_service_code":"6515"},{"award":{"date":"2026-04-27","amount":"764175.00","number":"36C25026P0614","awardee":{"raw":"PREMIER MEDICAL DISTRIBUTORS, LLC MYRTLE BEACH 29588 SCG","uei":"NXG6V8L9SY13","cage":"8HVU5","name":"PREMIER MEDICAL DISTRIBUTORS, LLC","location":{"zip":"29588","city":{"name":"MYRTLE BEACH"},"state":{"name":"SC"},"country":{"code":"SCG","name":"SERBIA AND MONTENEGRO"}}}},"dates":{"posted":"2026-04-27","posted_at":"2026-04-27T13:59:07.623Z","award_date":"2026-04-27","created_at":"2026-04-27T13:59:05.386Z","modified_at":"2026-06-27T03:55:47.176Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/61dbba77b02944e3b9b26703878f3fc8/view"},"naics":{"codes":["339113"],"primary":"339113"},"title":"6515--Guldmann Patient Ceiling Lifts Motors","agency":{"office":{"code":"36C250","name":"250-NETWORK CONTRACT OFFICE 10 (36C250)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"organization_id":"100167099","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-06-26","archive_type":"auto_custom"},"history":[{"index":6,"title":"6515--Guldmann Patient Ceiling Lifts Motors","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-27T13:59:07.623Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"61dbba77b02944e3b9b26703878f3fc8","solicitation_number":"36C25026Q0410","related_opportunity_id":"ba74f82dbb254337894e27ab4a1de9df"},{"index":4,"title":"6515--Guldmann Patient Ceiling Lift Motors","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-06T15:47:04.800Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ba74f82dbb254337894e27ab4a1de9df","solicitation_number":"36C25026Q0410"}],"contacts":[{"name":"Jeffrey Rozema","role":"primary","email":"jeffrey.rozema@va.gov","phone":"269-966-5600","title":"Contracting Officer"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"61dbba77b02944e3b9b26703878f3fc8","lineage_id":"ba74f82dbb254337894e27ab4a1de9df","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-06T01:11:52.154630169Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"905a737c9d1dd4b169c04875711faecced83b163a16df830161a8ccb60d4f5a3","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-06T01:11:52.154630169Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"36C25026Q0410","product_service_code":"6515"}],"due_at":"2026-04-16T21:00:00Z","due_date":"2026-04-16","closes_at":"2026-04-16T21:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","state":"OH","county":"39113","county_name":"Montgomery County","city":"3921000","city_name":"Dayton","country":"USA","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site_key":null,"winner_key":"NXG6V8L9SY13","amount":"764175.00","linked_awards":2,"cancelled":false,"archived":true,"updated_at":"2026-10-06T01:46:36.679440Z","principal_notice_id":"ba74f82dbb254337894e27ab4a1de9df","description":{"text":"Combined Synopsis-Solicitation for Commercial Products and Commercial Services\nDayton VA Medical Center\nGuldmann Patient Ceiling Lift Motors\n\nEffective Date: 01/15/2026\nRevision: 03\nDescription\nThis is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format Revolutionary FAR Overhaul (RFO) in Federal Acquisition Regulation (FAR) subpart 12.202, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued.\n\nThis solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-01 effective March 13, 2026.\n\nThis solicitation is not set-aside for small business.\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339113 Surgical Appliance and Supplies Manufacturing, with a small business size standard of 800 employees.\nThe FSC/PSC is 6515 Medical and Surgical Instruments, Equipment, and Supplies.\n\nThe Department of Veterans Affairs, Regional Procurement Office Central, Network Contracting Office 10, 5500 Armstrong Road, Battle Creek, MI 49037 is seeking to purchase Guldmann GH3+ patient ceiling lift motors including installation for the Dayton VA Medical Center located at 4100 West 3rd Street, Dayton, OH 45428.\n\nAll interested and qualified companies shall provide quotations for the following:\n\nSupplies/Services\n\nLine Item\nDescription\nQuantity\nUnit of Measure\nUnit Price\nTotal Price\n0001\nGuldmann GH3+ 605lbs SWL Hoist w/Scale CLM and Hanger Bar\n127\nEA\n\n0002\nGuldmann GH3+ Twin 1100lbs SWL Hoist w/Scale & Hanger Bar\n1\nEA\n\n0003\nCertified Installation - Hoist Replacement and Weight Test (includes Twin Swap)\n128\nEA\n\nStatement of Work\nBackground\nDayton VAMC is soliciting quotes for a contractor to provide all labor and materials to replace 128 end of life ceiling lift systems. Various lift weight capacities are required. New units to match existing lifts in the hospital to avoid misuse of unfamiliar equipment and allow for patient transfer between different lifts using a mutually compatible sling.\nScope\nContractor will provide equipment and services listed in this statement of work.\nThe Contractor will provide all necessary supplies, materials, equipment, qualified personnel, supervision, management, and transportation.\nAll work is to be performed in accordance with the guidelines established by Federal, State, and local ordinances and The Joint Commission. The Contractor s work procedures and quality control procedures shall conform to these guidelines.\nSpecific Tasks\nReplacement of 128 lift motors as detailed in Tables A-B. All lifts to undergo Certified Installation - Hoist Replacement and Weight Testing.\nTable A. GH3+ 605lbs SWL Hoist w/Scale & Hanger Bar\nCLC Main Tower\nQuantity: 38\n5D126-330\n5C113-330\n5C117-330\n5C12-330\n5D101-330\n5D104-330\n5D117-330\n5C118-330\n5C119-330\n5C127-330 (2x)\n\n5C127-330\n5C128-330\n5C129-330\n5C130-330\n5C133-330\n5C137-330\n5C138-330\n5C141-330\n5C142-330\n5C143-330\n5C144-330\n5C145-330\n5C147-330\n5D107-330\n5D108-330\n5D109-330\n5D116-330\n5D118-330\n5D122-330\n5D140-330\n5D130-330\n5D131-330\n5D132-330\n5D133-330\n5D134-330\n5D136-330\n5D138-330\n\nCLC Building\nQuantity: 47\n1A174-320\n1E124-320\n1A110-320\n1A113-320\n1A118-320\n1A120-320\n1A122-320\n1A126-320\n1A129-320 (2x)\n1A133-320\n1A134-320\n1D166-320\n\n1A137-320\n1A141-320\n1A159-320\n1A162-320\n1A163-320\n1A166-320\n1A167-320\n1A171-320\n1A176-320\n1B120-320\n1B137-320\n1B138-320\n1B141-320\n1B159-320\n1B162-320\n1B166-320\n1B170-320\n1B174-320\n1B175-320\n1C111-320\n1C115-320\n1C117-320\n1C118-320\n1C120-320\n1C121-320\n1C122-320\n1C123-320\n1C124-320\n1C136-320\n1C138-320\n1C139-320\n1C140-320\n1C141-320\n1C142-320\n\nDental Clinic\nQuantity: 1\n2B132-330\n\nEmergency Department\nQuantity: 1\n1G105-310\n\nGI Clinic\nQuantity: 1\nGI125-330\n\nMED 1 Unit\nQuantity: 20\n4C132-330\n4C145-330\n4C111-330\n4C112-330\n4C116-330\n\n4C118-330\n4C122-330\n4C130-330\n4C131-330\n4C134-330\n4C136-330\n4C139-330\n4C141A-330\n4C146-330\n4C147-330\n4C148-330\n4C150-330\n4C152-330\n4C153-330\n4C154-330\nRadiation Oncology\nQuantity: 2\n1-322\n\n30-322\n\nRadiology\nQuantity: 3\n1B114-330\n\n1B115-330\n1B123-330\n\nRenal Clinic\nQuantity: 1\n3C159-330\n\nSAM Unit\nQuantity: 7\n3D111-330\n3D134-330\n\n3D137-330\n3D119-330\n3D121-330\n3D133-330\n3D142-330\nSimulation Center\nQuantity: 6\n114-315\n116-315\n118-315\n119-315\n120-315\n\n124-315\n\nTable B. GH3+ Twin 1100lbs SWL Hoist w/Scale & Hanger Bar\nMorgue\nQuantity: 1\n2E142-310\n\nDisposal of old systems being removed from service.\nProvide education and training:\nOne session of training for biomedical engineering staff.\nTraining must include each new type of equipment and sling used in an area.\nPerform weight and function testing for each lift after installation in compliance with the VHA checklist required by Patient Safety Alert AL14-07. Each checklist shall be provided to Contracting Officer Representative within 7 days of installation along with any checklist required by the manufacturer. Any changes in inspection requirements during the period of installation will be communicated to the Contractor immediately.\nProvide the below deliverables.\nElectronic copies of the user manuals and repair manuals for each different model of lift installed under this order or contract at no additional cost to the government\nThis is a brand-name only solicitation for Guldmann GH3+ patient ceiling lifts/lift systems, which include equipment and installation for the Dayton VAMC.\nSystem Specifications:\nEach handset must have an integrated scale for patient weight built into the handset controller without compromising bed to hangar bar height and the ability to be safely secured to the lift when not in use.\nThe lift hand control must be attached to the lift hanger bar to avoid it from coming dislodged when not in use, potentially causing patient and/or healthcare worker injury.\nA wide range of mounting options (such as a lift system which can offer a combined wall and ceiling mount configuration) to accommodate the various patient room environments which exist within our facility.\nThe ability for full XY coverage in all patient care rooms, including therapy areas and maximum coverage in patient bathrooms.\nOperation of the system must allow for a minimum of 24 lifting height for transfer of patient from wheelchair/exam table/toilet, as well as adequate lifting height for the turning and repositioning of the patient on the exam table or lowering height for fall recovery off the floor.\nThe hanger bars must be able to be changed out by the medical center s staff without the assistance of contractors, vendors, or special tools.\nHangar bars must have 2- or 4-point hooks with secondary security measures, such as a steel or metal clip or double hook.\nLift systems must have software that allows for automatic tracking of preventative maintenance requirements as outlined in the National Patient Safety Alert AL 10-07 (2014). Tracking data must include the following: when service is next due, number of weighings, total lifetime lifts, dates of last timing belt and battery change and number of lifts since reset.\nTechnology that allows lift data to be viewed in Excel such as day & time of lifts, how long transfers are taking, height of the transfers, & weight of the transfers\nEmergency stopping device.\nThe emergency lowering feature must be operable without the use of any additional tools and the lift motor must be able to be reset by staff without any additional tools, allowing immediate use of the lift after activation of the emergency stop/lowering feature, without the need to call engineering or the manufacturer to reset the lift.\nSafety device that stops the motor lifting when batteries are low.\nLifting speed options up to 60mm/sec must be available.\nPlug and play technology must be employed to facilitate ease and reduced costs in system repairs and maintenance, one person replacement on current rail system.\nThe hoist must maintain a continuous charge on the rail.\nOperation of the system must be smooth with no fast or jerky starts and stops.\nCeiling lifts shall meet all Underwriters Laboratory requirements, life safety codes, national electric codes, fire safety codes, and all other applicable federal, state and local codes. Appropriate documentation should be provided.\nCeiling lifts shall comply with ISO 10535 (Hoists for the transfer of disabled persons Requirements and test methods).\nCeiling lifts must include a 2-point hanger bar, suitable and allowable for use with the full range of loop-based Guldmann slings, with 2 hooks facing different directions on each end of the bar and without easily breakable parts such as rubber flaps.\nThe lifts shall be mounted (using ceiling, wall, or floor support as determined by building structure and room covering layout needs) to provide lifting capability for the maximum area possible within each room which means wall to wall not just over the bed.\nLifts must be capable of picking patients up off the floor.\nLifts must not beep or flash during normal operation.\nLifts must be able to lift a full-capacity load at least 21 times on a full, new battery charge.\nCeiling lift motors shall be capable of lifting a weight no less than as specified in the replacement and installation tables.\nNew lifts shall accept generic type replacement batteries without voiding any warranties.\nMotors shall be GFCI protected.\nCeiling lifts vertical motion must be motorized.\nCeiling lifts that connect from one room to another must be designed so that they cannot come off the rail system while in use, and the connecting rail and the systems in both rooms must all hold at least as much weight as the lift motor.\nCeiling lifts must recharge automatically, by recharging at any location on the rail without employee action.\nCeiling lifts must include safeguards to prevent patients from being trapped or hurt, such as emergency stop buttons and emergency lowering devices in case of power failure. Use of emergency lowering devices must not require tools or ladders.\nPerformance Monitoring\nHealthcare Technology Management (HTM) will complete incoming inspection of the delivered units per manufacturer guidelines. Project COR and Patient Safe Handling and Mobility will monitor the project and coordinate installations with contractor personnel.\nSecurity Requirements\nThe C&A requirements do not apply, and a Security Accreditation Package is not required.\nGovernment-Furnished Equipment (GFE)/Government-Furnished Information (GFI)\nN/A\nOther Pertinent Information or Special Considerations\nAll work shall be in direct compliance in accordance with the VHA Safe Patient Handling and Mobility Directive 1611 (7/11/2023), and National Patient Safety Alert AL 14-07 (2014).\nEquipment and supplies must not be shipped before designs are approved and contractor has approval to install. Dayton VAMC cannot store uninstalled equipment for a significant length of time.\nAll contractors must pass VA adjudication and credentialing process.\nAll employees and subcontractors must wear a visible name and company identification when onsite. When more than one person is onsite performing work under this contract, one must be designated as a supervisor and must be fully responsible for the work to be performed.\nContractor personnel must conduct their work so as not to interfere with the normal functioning of the facility and will stop work if asked by Dayton VAMC personnel. Hours of work will need to be limited to daytime on units where patients sleep or to nighttime or weekends in areas where patients would be exposed by daytime work.\nThe Contractor shall take all precautions necessary to protect the lives and health of occupants of the building.\nThe Contractor must follow procedures required by Dayton VAMC Infection Control personnel and the construction safety committee, to include any required dust control specified in the Infection Control Risk Assessment.\nThe Contractor must state what efforts will be made to minimize noise during installation of equipment.\nThe Contractor shall immediately correct any fire and safety deficiencies caused by his personnel. If the contractor fails or refuses to correct deficiencies promptly, the Contracting Officer may issue an order stopping all or any part of the work and may hold the contractor in default of the contract.\nThe Contractor shall comply with applicable Federal, State, and local safety and fire regulations and codes which are in effect at the beginning of the contract period. The contractor shall keep abreast of any changes in these regulations and codes applicable to the contract. The contractor shall keep abreast of any changes in these regulations and codes applicable to the contract.\nAll material and equipment will be removed from the facility or stored properly at the end of each workday and secured during the workday in the areas specified by the Contracting Officer s Technical Representative.\nThe Contractor is responsible for supplying, completing, and submitting all reports required or requested by Federal, State, or local ordinances which pertain to any duties contained in the contract.\nThe Contractor will be required to furnish the Dayton VAMC with material safety data sheets for all chemicals used during installation. This information is required by the VA for emergency treatment in the event of ingestion of and/or contact with the material by humans and is required by OSHA regulations.\nThe Contractor s onsite lead installer must attend a Dayton VAMC construction safety orientation and supply job hazard analyses as required by Construction Safety Officer to show how hazards to Contractor and VHSO personnel are being minimized.\nAll Contractor personnel must have OSHA 10-hour construction safety training cards.\nThe Contractor s personnel shall follow applicable policies of the Dayton VAMC, to include policies concerning fire and disaster preparedness programs.\nThe contractor shall furnish at his own expense all labor, materials, machinery, and appliances which may be necessary or appropriate in the performance of this contract.\nAll accumulated rubbish is to be collected and placed in the dumpster provided by the Government. Large quantities need to be disposed of in ways that do not overload the dumpsters.\nThe contractor must have visited the sites and assessed the structure of each ceiling lift location to ensure safe installation of the equipment and shall supply the installation plans to the Dayton VAMC HTM Service, who must accept them before installation.\nCeiling lift installations shall comply with NFPA 13 for fire sprinklers and with NFPA 99 and NFPA 70 for proper grounding and bonding and access to electrical and safety systems.\nThe contractor should not require movement of any lights, sprinklers, televisions, or other fixtures in order to install ceiling lifts. If movement of preexisting fixtures is unavoidable, the contractor must include such notice when the bid is submitted.\nWall mounted lifts are acceptable in the place of ceiling mounts where they are more effective or cause less risk to install.\nCeiling lifts must not add obstacles or impair any normal operations in patient care rooms.\nIt is permissible to raise the lifting height or extend the range of a lift system that is being replaced, so long as designs are approved by the facility in advance and all obstacles are avoided to avoid interference with the operation of curtains, ventilation, or other moving or ceiling mounted items.\nAll installations that affect existing areas and electrical work shall be coordinated with Dayton VAMC HTM service.\nThe contractor will install all necessary mounts, braces, and any other components needed for full lift function and safety.\nChanges to Statement of Work: Any changes to this SOW shall be authorized and approved only through written correspondence from the CO. A copy of each change will be kept in a project folder along with all other products of the project. Costs incurred by the contractor through the actions of parties other than the CO shall be borne by the contractor.\nReporting Requirements: The VHA checklist and any manufacturer s checklist are the sole report and must be provided to the COR within 1 week of installation. Lift installation is not considered complete and cannot be paid for until the checklist is complete and provided to the COR.\nRisk Control\nContractor will be installing units in an active healthcare environment and will be required to comply with VAMC required above ceiling work permits, infection control procedures, and all OSHA requirements.\n\nPlace of Performance\n\nDayton VAMC\n4100 W. Third Street\nDayton OH 45428\nPeriod of Performance\nAll work shall be completed and in compliance within 180 calendar days from the contractor s receipt of the order. If for any reason any deliverable cannot be delivered within the scheduled time frame, the contractor is required to explain why in writing to the CO, including a firm commitment of when the work shall be completed. This notice to the CO shall cite the reasons for the delay, and the impact on the overall project. The CO will then review the facts and issue a response, in accordance with applicable regulations.\nDelivery Schedule\nDelivery to take place in batches with batch size to be determined by Dayton VAMC to prevent storage demands exceeding the capacity of Dayton VAMC s warehouse space.\n\nDelivery FOB Destination and installation no later than 180 days after receipt of order (ARO).\nPlace of Performance/Place of Delivery\nAddress:\nDepartment of Veterans Affairs\nDayton VA Medical Center\n4100 West 3rd Street\nDayton, OH\nPostal Code:\n45428\nCountry:\nUNITED STATES\n\nAll quoters shall submit the following:\n\nPrice quote.\nDocumentation from the OEM, Guldmann, Inc., indicating your company is an authorized supplier and installer for Guldmann lifts.\n\nAll quotes shall be sent to the Contracting Officer, Jeffrey Rozema, via email at jeffrey.rozema@va.gov.\n\nAward will be based on the lowest price for the exact items listed above.\n\nOfferors must complete annual representations and certifications electronically via the System for Award Management (SAM) website located at https://sam.gov/.\n\nTo facilitate the award process, all quotes must include a statement regarding the terms and conditions herein as follows:\n\"The terms and conditions in the solicitation are acceptable to be included in the award document without modification, deletion, or addition.\"\nOR\n\"The terms and conditions in the solicitation are acceptable to be included in the award document with the exception, deletion, or addition of the following:\"\nQuoters shall list exception(s) and rationale for the exception(s), if any.\n\nSubmission of your response shall be received not later than 5:00 PM Eastern Time, Thursday, April 16, 2026, by email at jeffrey.rozema@va.gov.\n\nLate submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f).\n\nAny questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below.\nPoint of Contact\nPoint of contact for this solicitation is Jeffrey Rozema, Contracting Officer, email: jeffrey.rozema@va.gov.","html":"Combined Synopsis-Solicitation for Commercial Products and Commercial Services\nDayton VA Medical Center\nGuldmann Patient Ceiling Lift Motors \n\nEffective Date:  01/15/2026\nRevision: 03\nDescription\nThis is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format Revolutionary FAR Overhaul (RFO) in Federal Acquisition Regulation (FAR) subpart 12.202,  Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services,  as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued.\n\nThis solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-01 effective March 13, 2026.\n\nThis solicitation is not set-aside for small business.\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339113   Surgical Appliance and Supplies Manufacturing, with a small business size standard of 800 employees.\nThe FSC/PSC is 6515   Medical and Surgical Instruments, Equipment, and Supplies.\n\nThe Department of Veterans Affairs, Regional Procurement Office Central, Network Contracting Office 10, 5500 Armstrong Road, Battle Creek, MI 49037 is seeking to purchase Guldmann GH3+ patient ceiling lift motors including installation for the Dayton VA Medical Center located at 4100 West 3rd Street, Dayton, OH 45428.\n\nAll interested and qualified companies shall provide quotations for the following:\n\nSupplies/Services\n\nLine Item\nDescription\nQuantity\nUnit of Measure\nUnit Price\nTotal Price\n0001\nGuldmann GH3+ 605lbs SWL Hoist w/Scale CLM and Hanger Bar\n127\nEA\n\n\n0002\nGuldmann GH3+ Twin 1100lbs SWL Hoist w/Scale & Hanger Bar\n1\nEA\n\n\n0003\nCertified Installation - Hoist Replacement and Weight Test (includes Twin Swap)\n128\nEA\n\n\nStatement of Work\nBackground\nDayton VAMC is soliciting quotes for a contractor to provide all labor and materials to replace 128 end of life ceiling lift systems. Various lift weight capacities are required. New units to match existing lifts in the hospital to avoid misuse of unfamiliar equipment and allow for patient transfer between different lifts using a mutually compatible sling.\nScope\nContractor will provide equipment and services listed in this statement of work.\nThe Contractor will provide all necessary supplies, materials, equipment, qualified personnel, supervision, management, and transportation. \nAll work is to be performed in accordance with the guidelines established by Federal, State, and local ordinances and The Joint Commission. The Contractor s work procedures and quality control procedures shall conform to these guidelines.\nSpecific Tasks  \nReplacement of 128 lift motors as detailed in Tables A-B. All lifts to undergo Certified Installation - Hoist Replacement and Weight Testing.\nTable A. GH3+ 605lbs SWL Hoist w/Scale & Hanger Bar\nCLC   Main Tower\nQuantity: 38\n5D126-330\n5C113-330\n5C117-330\n5C12-330\n5D101-330\n5D104-330\n5D117-330\n5C118-330\n5C119-330\n5C127-330 (2x)\n\n5C127-330\n5C128-330\n5C129-330\n5C130-330\n5C133-330\n5C137-330\n5C138-330\n5C141-330\n5C142-330\n5C143-330\n5C144-330\n5C145-330\n5C147-330\n5D107-330\n5D108-330\n5D109-330\n5D116-330\n5D118-330\n5D122-330\n5D140-330\n5D130-330\n5D131-330\n5D132-330\n5D133-330\n5D134-330\n5D136-330\n5D138-330\n\nCLC Building\nQuantity: 47\n1A174-320\n1E124-320\n1A110-320\n1A113-320\n1A118-320\n1A120-320\n1A122-320\n1A126-320\n1A129-320 (2x)\n1A133-320\n1A134-320\n1D166-320\n\n1A137-320\n1A141-320\n1A159-320\n1A162-320\n1A163-320\n1A166-320\n1A167-320\n1A171-320\n1A176-320\n1B120-320\n1B137-320\n1B138-320\n1B141-320\n1B159-320\n1B162-320\n1B166-320\n1B170-320\n1B174-320\n1B175-320\n1C111-320\n1C115-320\n1C117-320\n1C118-320\n1C120-320\n1C121-320\n1C122-320\n1C123-320\n1C124-320\n1C136-320\n1C138-320\n1C139-320\n1C140-320\n1C141-320\n1C142-320\n\nDental Clinic\nQuantity: 1\n2B132-330\n\n\n\n\n Emergency Department\nQuantity: 1\n1G105-310\n\n\n\n\n GI Clinic\nQuantity: 1\nGI125-330\n\n\n\n\n MED 1 Unit\nQuantity: 20\n4C132-330\n4C145-330\n4C111-330\n4C112-330\n4C116-330\n\n4C118-330\n4C122-330\n4C130-330\n4C131-330\n4C134-330\n4C136-330\n4C139-330\n4C141A-330\n4C146-330\n4C147-330\n4C148-330\n4C150-330\n4C152-330\n4C153-330\n4C154-330\n Radiation Oncology\nQuantity: 2\n1-322\n\n30-322\n\n\n Radiology\nQuantity: 3\n1B114-330\n\n1B115-330\n1B123-330\n\n Renal Clinic\nQuantity: 1\n3C159-330\n\n\n\n\n SAM Unit\nQuantity: 7\n3D111-330\n3D134-330\n\n3D137-330\n3D119-330\n3D121-330\n3D133-330\n3D142-330\nSimulation Center\nQuantity: 6\n114-315\n116-315\n118-315\n119-315\n120-315\n\n124-315\n\n\nTable B. GH3+ Twin 1100lbs SWL Hoist w/Scale & Hanger Bar\nMorgue\nQuantity: 1\n2E142-310\n\n\n\nDisposal of old systems being removed from service.\nProvide education and training:\nOne session of training for biomedical engineering staff.\nTraining must include each new type of equipment and sling used in an area.\nPerform weight and function testing for each lift after installation in compliance with the VHA checklist required by Patient Safety Alert AL14-07. Each checklist shall be provided to Contracting Officer Representative within 7 days of installation along with any checklist required by the manufacturer. Any changes in inspection requirements during the period of installation will be communicated to the Contractor immediately. \nProvide the below deliverables.\nElectronic copies of the user manuals and repair manuals for each different model of lift installed under this order or contract at no additional cost to the government\nThis is a brand-name only solicitation for Guldmann GH3+ patient ceiling lifts/lift systems, which include equipment and installation for the Dayton VAMC.\nSystem Specifications:\nEach handset must have an integrated scale for patient weight built into the handset controller without compromising bed to hangar bar height and the ability to be safely secured to the lift when not in use.\nThe lift hand control must be attached to the lift hanger bar to avoid it from coming dislodged when not in use, potentially causing patient and/or healthcare worker injury.\nA wide range of mounting options (such as a lift system which can offer a combined wall and ceiling mount configuration) to accommodate the various patient room environments which exist within our facility. \nThe ability for full XY coverage in all patient care rooms, including therapy areas and maximum coverage in patient bathrooms.\nOperation of the system must allow for a minimum of 24  lifting height for transfer of patient from wheelchair/exam table/toilet, as well as adequate lifting height for the turning and repositioning of the patient on the exam table or lowering height for fall recovery off the floor. \nThe hanger bars must be able to be changed out by the medical center s staff without the assistance of contractors, vendors, or special tools. \nHangar bars must have 2- or 4-point hooks with secondary security measures, such as a steel or metal clip or double hook.\nLift systems must have software that allows for automatic tracking of preventative maintenance requirements as outlined in the National Patient Safety Alert AL 10-07 (2014).  Tracking data must include the following: when service is next due, number of weighings, total lifetime lifts, dates of last timing belt and battery change and number of lifts since reset.\nTechnology that allows lift data to be viewed in Excel such as day & time of lifts, how long transfers are taking, height of the transfers, & weight of the transfers \nEmergency stopping device.\nThe emergency lowering feature must be operable without the use of any additional tools and the lift motor must be able to be reset by staff without any additional tools, allowing immediate use of the lift after activation of the emergency stop/lowering feature, without the need to call engineering or the manufacturer to reset the lift.\nSafety device that stops the motor lifting when batteries are low.\nLifting speed options up to 60mm/sec must be available.\nPlug and play technology must be employed to facilitate ease and reduced costs in system repairs and maintenance, one person replacement on current rail system.\nThe hoist must maintain a continuous charge on the rail. \nOperation of the system must be smooth with no fast or jerky starts and stops.\nCeiling lifts shall meet all Underwriters Laboratory requirements, life safety codes, national electric codes, fire safety codes, and all other applicable federal, state and local codes. Appropriate documentation should be provided.\nCeiling lifts shall comply with ISO 10535 (Hoists for the transfer of disabled persons   Requirements and test methods).\nCeiling lifts must include a 2-point hanger bar, suitable and allowable for use with the full range of loop-based Guldmann slings, with 2 hooks facing different directions on each end of the bar and without easily breakable parts such as rubber flaps.\nThe lifts shall be mounted (using ceiling, wall, or floor support as determined by building structure and room covering layout needs) to provide lifting capability for the maximum area possible within each room which means wall to wall   not just over the bed.\nLifts must be capable of picking patients up off the floor.\nLifts must not beep or flash during normal operation.\nLifts must be able to lift a full-capacity load at least 21 times on a full, new battery charge.\nCeiling lift motors shall be capable of lifting a weight no less than as specified in the replacement and installation tables.\nNew lifts shall accept generic type replacement batteries without voiding any warranties.\nMotors shall be GFCI protected.\nCeiling lifts  vertical motion must be motorized.\nCeiling lifts that connect from one room to another must be designed so that they cannot come off the rail system while in use, and the connecting rail and the systems in both rooms must all hold at least as much weight as the lift motor.\nCeiling lifts must recharge automatically, by recharging at any location on the rail without employee action.\nCeiling lifts must include safeguards to prevent patients from being trapped or hurt, such as emergency stop buttons and emergency lowering devices in case of power failure. Use of emergency lowering devices must not require tools or ladders.\nPerformance Monitoring\nHealthcare Technology Management (HTM) will complete incoming inspection of the delivered units per manufacturer guidelines. Project COR and Patient Safe Handling and Mobility will monitor the project and coordinate installations with contractor personnel. \nSecurity Requirements\nThe C&A requirements do not apply, and a Security Accreditation Package is not required. \nGovernment-Furnished Equipment (GFE)/Government-Furnished Information (GFI)  \nN/A\nOther Pertinent Information or Special Considerations \nAll work shall be in direct compliance in accordance with the VHA Safe Patient Handling and Mobility Directive 1611 (7/11/2023), and National Patient Safety Alert AL 14-07 (2014). \nEquipment and supplies must not be shipped before designs are approved and contractor has approval to install. Dayton VAMC cannot store uninstalled equipment for a significant length of time.\nAll contractors must pass VA adjudication and credentialing process.\nAll employees and subcontractors must wear a visible name and company identification when onsite. When more than one person is onsite performing work under this contract, one must be designated as a supervisor and must be fully responsible for the work to be performed.\nContractor personnel must conduct their work so as not to interfere with the normal functioning of the facility and will stop work if asked by Dayton VAMC personnel. Hours of work will need to be limited to daytime on units where patients sleep or to nighttime or weekends in areas where patients would be exposed by daytime work.\nThe Contractor shall take all precautions necessary to protect the lives and health of occupants of the building.\nThe Contractor must follow procedures required by Dayton VAMC Infection Control personnel and the construction safety committee, to include any required dust control specified in the Infection Control Risk Assessment.\nThe Contractor must state what efforts will be made to minimize noise during installation of equipment.\nThe Contractor shall immediately correct any fire and safety deficiencies caused by his personnel. If the contractor fails or refuses to correct deficiencies promptly, the Contracting Officer may issue an order stopping all or any part of the work and may hold the contractor in default of the contract.\nThe Contractor shall comply with applicable Federal, State, and local safety and fire regulations and codes which are in effect at the beginning of the contract period. The contractor shall keep abreast of any changes in these regulations and codes applicable to the contract. The contractor shall keep abreast of any changes in these regulations and codes applicable to the contract.\nAll material and equipment will be removed from the facility or stored properly at the end of each workday and secured during the workday in the areas specified by the Contracting Officer s Technical Representative.\nThe Contractor is responsible for supplying, completing, and submitting all reports required or requested by Federal, State, or local ordinances which pertain to any duties contained in the contract.\nThe Contractor will be required to furnish the Dayton VAMC with material safety data sheets for all chemicals used during installation. This information is required by the VA for emergency treatment in the event of ingestion of and/or contact with the material by humans and is required by OSHA regulations.\nThe Contractor s onsite lead installer must attend a Dayton VAMC construction safety orientation and supply job hazard analyses as required by Construction Safety Officer to show how hazards to Contractor and VHSO personnel are being minimized.\nAll Contractor personnel must have OSHA 10-hour construction safety training cards.\nThe Contractor s personnel shall follow applicable policies of the Dayton VAMC, to include policies concerning fire and disaster preparedness programs.\nThe contractor shall furnish at his own expense all labor, materials, machinery, and appliances which may be necessary or appropriate in the performance of this contract.\nAll accumulated rubbish is to be collected and placed in the dumpster provided by the Government. Large quantities need to be disposed of in ways that do not overload the dumpsters.\nThe contractor must have visited the sites and assessed the structure of each ceiling lift location to ensure safe installation of the equipment and shall supply the installation plans to the Dayton VAMC HTM Service, who must accept them before installation.\nCeiling lift installations shall comply with NFPA 13 for fire sprinklers and with NFPA 99 and NFPA 70 for proper grounding and bonding and access to electrical and safety systems.\nThe contractor should not require movement of any lights, sprinklers, televisions, or other fixtures in order to install ceiling lifts. If movement of preexisting fixtures is unavoidable, the contractor must include such notice when the bid is submitted.\nWall mounted lifts are acceptable in the place of ceiling mounts where they are more effective or cause less risk to install.\nCeiling lifts must not add obstacles or impair any normal operations in patient care rooms.\nIt is permissible to raise the lifting height or extend the range of a lift system that is being replaced, so long as designs are approved by the facility in advance and all obstacles are avoided to avoid interference with the operation of curtains, ventilation, or other moving or ceiling mounted items.\nAll installations that affect existing areas and electrical work shall be coordinated with Dayton VAMC HTM service.\nThe contractor will install all necessary mounts, braces, and any other components needed for full lift function and safety.\nChanges to Statement of Work: Any changes to this SOW shall be authorized and approved only through written correspondence from the CO. A copy of each change will be kept in a project folder along with all other products of the project. Costs incurred by the contractor through the actions of parties other than the CO shall be borne by the contractor.\nReporting Requirements: The VHA checklist and any manufacturer s checklist are the sole report and must be provided to the COR within 1 week of installation. Lift installation is not considered complete and cannot be paid for until the checklist is complete and provided to the COR.\nRisk Control\nContractor will be installing units in an active healthcare environment and will be required to comply with VAMC required above ceiling work permits, infection control procedures, and all OSHA requirements.\n\nPlace of Performance\n\nDayton VAMC \n4100 W. Third Street\nDayton OH 45428\nPeriod of Performance \nAll work shall be completed and in compliance within 180 calendar days from the contractor s receipt of the order. If for any reason any deliverable cannot be delivered within the scheduled time frame, the contractor is required to explain why in writing to the CO, including a firm commitment of when the work shall be completed. This notice to the CO shall cite the reasons for the delay, and the impact on the overall project. The CO will then review the facts and issue a response, in accordance with applicable regulations.\nDelivery Schedule \nDelivery to take place in batches with batch size to be determined by Dayton VAMC to prevent storage demands exceeding the capacity of Dayton VAMC s warehouse space.\n\nDelivery FOB Destination and installation no later than 180 days after receipt of order (ARO).\nPlace of Performance/Place of Delivery\nAddress:\nDepartment of Veterans Affairs\nDayton VA Medical Center\n4100 West 3rd Street\nDayton, OH \nPostal Code:\n45428\nCountry:\nUNITED STATES\n\nAll quoters shall submit the following: \n\nPrice quote.\nDocumentation from the OEM, Guldmann, Inc., indicating your company is an authorized supplier and installer for Guldmann lifts.\n\nAll quotes shall be sent to the Contracting Officer, Jeffrey Rozema, via email at jeffrey.rozema@va.gov.\n\nAward will be based on the lowest price for the exact items listed above.\n\n\nOfferors must complete annual representations and certifications electronically via the System for Award Management (SAM) website located at https://sam.gov/.\n\nTo facilitate the award process, all quotes must include a statement regarding the terms and conditions herein as follows:\n\"The terms and conditions in the solicitation are acceptable to be included in the award document without modification, deletion, or addition.\"\nOR\n\"The terms and conditions in the solicitation are acceptable to be included in the award document with the exception, deletion, or addition of the following:\"\n Quoters shall list exception(s) and rationale for the exception(s), if any.\n\nSubmission of your response shall be received not later than 5:00 PM Eastern Time, Thursday, April 16, 2026, by email at jeffrey.rozema@va.gov.\n\nLate submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f).  \n\nAny questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below. \nPoint of Contact\nPoint of contact for this solicitation is Jeffrey Rozema, Contracting Officer, email: jeffrey.rozema@va.gov.","origin":"detail"},"contacts":[{"name":"Jeffrey Rozema","role":"primary","email":"jeffrey.rozema@va.gov","phone":"269-966-5600","title":"Contracting Officer"}],"place_of_performance":{"zip":"45428","city":{"code":"21000","name":"Dayton"},"state":{"code":"OH","name":"Ohio"},"street":"Department of Veterans Affairs Dayton VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"4100 West 3rd Street"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"naics_codes":["339113"],"award":{"awardee":{}},"attachments":[{"resource_id":"1e7b2c8f52eb4c7e937abe7a341f258b","name":"36C25026P0614_1.docx","kind":"file","mime_type":".docx","size_bytes":13705,"posted_at":"2026-04-27T13:59:07.623Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/1e7b2c8f52eb4c7e937abe7a341f258b/download","mirrored":false},{"resource_id":"3b61551eaeb04d36aafbe40c3d6485b0","name":"36C25026Q0410.docx","kind":"file","mime_type":".docx","size_bytes":31168,"posted_at":"2026-04-06T15:47:04.800Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/3b61551eaeb04d36aafbe40c3d6485b0/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C25026P0614_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C25026P0614_3600_-NONE-_-NONE-/","piid":"36C25026P0614","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"NXG6V8L9SY13","recipient_name":"PREMIER MEDICAL DISTRIBUTORS, LLC","recipient_uei":"NXG6V8L9SY13","recipient_cage":"8HVU5","recipient_city":"MYRTLE BEACH","recipient_state":"SC","sub_name":"Department of Veterans Affairs","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","office_key":"o-36C250","first_action_date":"2026-04-27","last_action_date":"2026-04-27","actions":1,"obligated":"764175.00","current_total_value":"764175.00","potential_total_value":"764175.00","naics":"339113","psc":"6515","extent_competed":"COMPETED UNDER SAP","set_aside":"NO SET ASIDE USED.","offers_received":3,"description":"GULDMANN PATIENT CEILING LIFTS","method":"piid","confidence":"high","evidence":["award number 36C25026P0614 equals the contract number","same awarding office 36C250"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C25027Q0014","latest_notice_id":"b13cc87179e947e7b42da2de44a6bde1","title":"J061--541 Electrical Power Distribution Equipment Testing, Inspection, and Maintenance - VAMC Cleveland","solicitation_number":"36C25027Q0014","notice_type":"k","first_type":"k","first_posted":"2026-10-09","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"238210","psc":"J061","set_aside":"SBA","state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C25027Q0123","latest_notice_id":"fb53a332644a4c8fa983bf28c8643d2d","title":"S222--Sources Sought - Hazardous Waste Removal/Disposal Northeast Ohio VA Healthcare System - Cleveland, OH","solicitation_number":"36C25027Q0123","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T18:30:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"562112","psc":"S222","set_aside":null,"state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C25027B0009","latest_notice_id":"85b83d408f1f422885991142c2734b45","title":"Z1DA--FY27 NRM - VISN Base Modernize Nurse Call - 539-23-101","solicitation_number":"36C25027B0009","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"},{"key":"36C25027B0008","latest_notice_id":"5afe716a38494a6f84b1e84205805f86","title":"Z1DA--FY27 NRM - VISN Base Install Roof Equipment Railings - 539-22-206","solicitation_number":"36C25027B0008","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"},{"key":"36C25027B0005","latest_notice_id":"2cb4a6354be04cc89c5d6125945b1892","title":"Z1DA--***FY27 Requirement*** First Floor X Ray - Room CC157 553-CSI-022","solicitation_number":"36C25027B0005","notice_type":"p","first_type":"p","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"MI","county":"26163","county_name":"Wayne County","city":"2622000","city_name":"Detroit","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"}],"similar_open":[{"key":"36C26027Q0130","latest_notice_id":"865639d03bae440aaa4a2e2195e0abf9","title":"6515--SOURCES SOUGHT NOTICE FOR HEAD, SHOULDER, AND UPPER-EXTREMITY POSITIONING ACCESSORIES FOR THE MAQUET MEERA 7200 OPERATING TABLE","solicitation_number":"36C26027Q0130","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":2,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"339113","psc":"6515","set_aside":null,"state":"WA","county":"53063","county_name":"Spokane County","city":"5367000","city_name":"Spokane","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"N0010427QLA17","latest_notice_id":"5958ba02b5c94595a30747ebb8d1c461","title":"VALVE,BREATHING APP","solicitation_number":"N0010427QLA17","notice_type":"o","first_type":"o","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-27T20:30:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"339113","psc":"4240","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"IN THE SCHEDULE. ^^ \"ALL FREIGHT IS FOB ORIGIN","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"36C25727Q0104","latest_notice_id":"9c3ddb4326164d4fa71ad956d4194f7c","title":"6515--36C257-27-AP-0953 Prosthetic STX 671 O2 Equipment (VA-27-00016458)","solicitation_number":"36C25727Q0104","notice_type":"o","first_type":"p","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":3,"due_at":"2026-11-30T19:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"339113","psc":"6515","set_aside":"SDVOSBC","state":"TX","county":"48029","county_name":"Bexar County","city":"4865000","city_name":"San Antonio","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":19,"indexable":false}