{"canonical":"https://sealedbidder.com/opportunities/36c25026q0271","key":"36C25026Q0271","url":"https://sealedbidder.com/opportunities/36c25026q0271","title":"J046--Reverse Osmosis Systems PM","solicitation_number":"36C25026Q0271","notice_type":"s","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-02-16T15:00:00Z","first_posted":"2026-01-30","last_posted":"2026-01-30","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"221310","psc":"J046","set_aside":null,"place_state":"MI","place_scope":"site","site":null,"place_state_source":"description","place_evidence":"AAVA) LOCATED AT 2215 FULLER ROAD, ANN ARBOR, MI 48105","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"08be48e86fd24f8790210281421f884c","title":"J046--Reverse Osmosis Systems PM","solicitation_number":"36C25026Q0271","notice_type":"s","base_type":"s","posted":"2026-01-30","posted_at":"2026-01-30T15:13:52.975Z","due_at":"2026-02-16T15:00:00Z","due_date":"2026-02-16","cancelled":false,"archived":true,"archive_date":"2026-03-18","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/08be48e86fd24f8790210281421f884c/view","enriched":true,"history":[{"index":3,"title":"J046--Reverse Osmosis Systems PM","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-30T15:13:52.975Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"08be48e86fd24f8790210281421f884c","solicitation_number":"36C25026Q0271"}]}],"latest_notice_id":"08be48e86fd24f8790210281421f884c","first_type":"s","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-01-30","posted_at":"2026-01-30T15:13:52.975Z","created_at":"2026-01-30T15:13:50.766Z","modified_at":"2026-03-19T03:55:44.197Z","response_deadline":{"raw":"2026-02-16T10:00:00-05:00","utc":"2026-02-16T15:00:00Z","date":"2026-02-16","time":"10:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/08be48e86fd24f8790210281421f884c/view"},"naics":{"codes":["221310"],"primary":"221310"},"title":"J046--Reverse Osmosis Systems PM","agency":{"office":{"code":"36C250","name":"250-NETWORK CONTRACT OFFICE 10 (36C250)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"organization_id":"100167099","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-03-18","archive_type":"auto_custom"},"history":[{"index":3,"title":"J046--Reverse Osmosis Systems PM","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-30T15:13:52.975Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"08be48e86fd24f8790210281421f884c","solicitation_number":"36C25026Q0271"}],"contacts":[{"name":"Jeannie Ortiz","role":"primary","email":"jeanne.ortiz@va.gov","phone":"NO PHONE CALLS ACCEPTED","title":"Contracting Officer"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"08be48e86fd24f8790210281421f884c","lineage_id":"08be48e86fd24f8790210281421f884c","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-14T08:10:19.168903271Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"3fcd0d91c075cb215f7af29be1aad2ce6ff580046639e8e5797ee851cecc7efb","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-14T08:10:19.168903271Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"This is a Sources Sought Notice for Reverse Osmosis Water System Maintenance Services as identified in the Statement of Work (SOW) for the Ann Arbor VA Medical Center in Ann Arbor, Michigan. The contractor shall furnish all necessary tools, parts, labor, supplies, materials, equipment, supervision and transportation necessary to furnish the services noted below.\n\nA DRAFT SOW is attached to this notice and is subject to change should a solicitation be issued as a result of this notice. \n\nPlease respond if you have the ability and actual intention to complete this requirement. All of the following information is required in your response:\n\nSAM UEI NUMBER   provide this in the email text\nGSA Contract Number   provide this in the email text\nCapabilities Statement\nConfirmation of actual intent to submit an offer should an RFQ be posted in future\nCompany name and address\nPoint of contact information (name, phone, email)\nSocioeconomic size status (example: large business, small business, WOSB, SDVOSB, etc.)   provide this in the email text\n\nThis Sources Sought Notice is intended to locate any business capable of performance.\n\nThe anticipated NAICS Code for this requirement is 221310.\n\nThis is not a Request for Quotation and quotes shall not be reviewed at this time.\n\nThe Government shall not be responsible for any costs incurred by the contractor because of this Sources Sought Notice.\n\nThis notice shall not be construed as a commitment by the Government to ultimately award a contract, nor does it restrict the Government to any particular acquisition approach. All information submitted in response to this announcement is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government.\n\nResponses shall be submitted by email only, to Jeannie Ortiz, at jeanne.ortiz@va.gov by Monday, February 16, 2026, at 10:00 AM Eastern Time (ET). Responses MUST include 36C25026Q0271 in the subject line. PHONE CALLS SHALL NOT BE ACCEPTED FOR THIS NOTICE.\n\nDRAFT STATEMENT OF WORK\n\nGENERAL: Contractor shall provide all labor, parts, materials, personnel, transportation and \nsupervision to perform preventive maintenance and non-routine emergency maintenance services of the Reverse Osmosis (RO) Equipment Systems located at the Ann Arbor VA Medical Center (AAVA) located at 2215 Fuller Road, Ann Arbor, MI 48105.  \n\nThe Reverse Osmosis (RO) Water Equipment Systems are comprised of one set of RO water systems serving Sterile Processing Service (SPS) and one set of RO water systems serving Laboratory Department (Lab).\nPreventive maintenance services consist of evaluating system components, replacing consumable system components, generating Field Service Reports and recommending corrective actions for deficiencies.\nEmergency maintenance services consist of making timely and critical repairs to reverse osmosis equipment to ensure uninterrupted operation of the process water.  \n \nCONFORMANCE STANDARDS: Services provided in this contract shall conform to original \nequipment manufacturer maintenance and operation instructions, ST108 Standard, AAMI Standard 79, and AAMI TIR 34:2014 recommendations for the water quality necessary for the reprocessing of medical instruments, and all other applicable AAMI Standards. \n\nSCOPE OF WORK: The Preventive Maintenance Service shall consist of quarterly, semi-annual, \nannual visits to meet scheduled maintenance intervals. Preventive Maintenance shall be performed on the components listed below at the specified intervals and Emergency Services will be performed on an as needed basis: \n\nSterile Processing Service (SPS)   Reverse Osmosis Water Systems Preventive Maintenance Services\nSPS - Preventive Maintenance   Quarterly:\nReplace Hot Water Prefilter Housing (Part No.: W2T934190, Quantity: 5)\nReplace Cold Water Prefilter Housing (Part No.: W2T159682, Quantity: 5)  \nReplace 20\", \"Big Blue\" Inlet Pre-Filter (Model No.: FCXBF2005, Part No.: W2T150325, Quantity: 1)\nDeliver 3.6 cu. ft. Mixed Bed Tank and Replace as indicated by monthly evaluations (Part No.: W5TDIMB10360FSP, Quantity: 1) \n\nSPS - Preventive Maintenance   Semi-Annually:\nReplace 3.6 cu. ft. Carbon Tank (Part No.: W5TDIRAC0360FSP, Quantity: 1)\nReplace 10\", 0.2 Micron Filter (Model No.: FCWNF09S2, Part No.: W2T177036, Quantity: 1)\nReplace Ultraviolet Bulb (Model No.: ZCSPL3084, Part No.: W2T472870, Quantity: 2)\nReplace Ultraviolet Quartz Sleeve (Model No.: ZCSPQ3184, Part No.: W2T164367, Quantity: 2)\n\nSPS - Preventive Maintenance   Annually:\nReplace Reverse Osmosis Membrane Filters (Part No. W2T844451, Quantity: 6)\nPerform Loop Sanitizing (Part No. W3TSP4707)\nReplace Filter Cartridges, 20\", 0.05um HLLW FBR UF CODE (Part No.: W2T149000, Quantity: 7)\nReplace Filter, 10\", 0.2um, Code F Pleated Vent (Part No.: W2T915015, Quantity: 1)\nReplace Filter Cap, 0.2UM 1-2 NPT (Part No.: W2T165344, Quantity: 6)\n\nLaboratory Department   Reverse Osmosis Water Systems Preventive Maintenance Services\nMedica 15, Room E326 (Serial No.: ME00015946, ID No: 0013008807) Semi-Annually: \nReplace Pre-Treatment Cartridge For Small O (Part No.: W2T167305, Quantity: 1)\nReplace Filter CTRDG, Deionization DI Twin Pac (Part No.: W2T167306, Quantity: 1)\nReplace Filter Cap, In Line 0.2um (Part No.: W2T167312, Quantity: 1)\nReplace Filter, Composite Vent Air 0.2um (Part No.: W2T167303, Quantity: 1)\nReplace Cart 20  5um Code F PP String Wound (Part No.: W2T170725, Quantity: 1)\nReplace Lamp, UV 254 NM for Optn 2/4/5 Medi (Part No.: W2T167317, Quantity: 1)\nReplace RO Cartridge 7.5 LPH Flow Rate (Part No.: W2T167307, Quantity: 2)\nReplace Duplex, Pretreatment kit for Small B (Part No.: W3T185358, Quantity: 1)\nSDI React Carbon .25CF FLAT P   Carbon Tank (Part No. W5TDIRAC0025FFP)\n\nEmergency Services:\nContractor shall provide the Service POC/COR with emergency telephone numbers to call in the event of an emergency. At least one of the emergency telephone numbers shall be manned twenty-four (24) hours per day, 365 days per year. This information shall be provided in writing to the Service POC/COR.\nContractor shall respond to all callbacks and be prepared to take corrective action at the site within 8 hours for all emergency service calls.\nCallbacks hours are not to take time away from preventive maintenance hours required under this contract. \nEquipment malfunctions shall be corrected the same day that the emergency service call was made. If circumstances beyond the Contractor s control preclude resolution of the problem that day, the Service POC/COR must be notified in writing with an explanation of the delay. \nAll AAMI required tests shall be performed at the conclusion of emergency work and reported in accordance with Section E. \n\nCOVERED EQUIPMENT: The following equipment and/or components shall be covered for emergency service. Contractor staff shall be qualified to service, adjust and maintain: \n\nSterile Processing Service:\nW2T164518, HOUSING FLTR INDUSTRIAL 304SS 5 RD - Prefilter Housing Qty 2\nW5TDIRAC0360FSP, SDI REACT CARBON 3.6CF FBGLS STD PO Qty 1 \nW3T332697, M41RGP 3 MEMB VERT 460VAC (M41RGPV003D) Qty 1 \nW5TDIMB10360FSP, SDI MIXBED1 3.6CF FBGLS STD POT Qty 1 \nW2T813107, TANK,CONE BTM 500GAL PE STD Qty 1 \nW2T165787, CART 10\" 0.2UM CODE F PLTD VNT Qty 1 \nW2T179895, PUMP MULTI CEN 3PH 460 CRNE5-5, Qty 2 \nW2T185418, Panel Qty 1 \nW2T144487, UV UNIT,DISFECT MP2SL 120V/60HZ NO OPTNS; Qty 1 \nW2T541231, TRANSMITTER,M800 ISM/PULSE 120VAC 4 CH; Qty 1 \nW2T149000, 7 Round Ultrafilter Housing Qty 1 \n\nLab Services:\nW3T317159, Kit, Leak Prevent 115 .500  No BRS VLV; Qty 1\nW2T809169, Valve, PRV .50  .25  NPT F I/O 250 PSI BRZ; Qty 1\nW2T177833, Medica 15 W/BOOSTER PUMP; Qty 1\nW2T159477, DV25 MODUL DOCK VSL 25 LIT; Qty 1\nW2T183873, BRACKET, WALL MOT 25/40L RESERV; Qty 1\nW2T169124, VALVE, SHUT OFF 0.3125  USH FIT, Qty 7\nW5TDIRAC0025FFP, Carbon Tank, Qty 1\n\nDELIVERABLE REPORTS: Contractor shall deliver legible field service reports immediately at the completion of each visit. Reports shall detail the work performed and include work technician name(s), arrival and departure times, issues found, and any deviations from planned work.\n\nREPORTING REQUIREMENTS: \nThe Contractor is required to schedule an appropriate service date with Facilities Management two weeks in advance of performance. The service dates will be subject to short notice or immediate change based on operational needs of the affected departments. The Service POC/COR will coordinate with Sterile Processing Service to minimize operational impacts and preserve the schedule as best as possible. The Service POC/COR shall have final approval of the day and time for the Preventive Maintenance. \nContractor check-in is mandatory. Contractor staff shall check-in with the Plant Supervisor or designee, located in the Energy Center, Building 32, and sign into the Plant daily logbook with arrival time, name of technician(s) and general nature of the visit. \nScheduled services will be performed during normal business hours, Monday through Friday, 8:30 am to 4:30 pm. The VA reserves the right to request certain services be performed after hours or weekends based on the needs of the facility, at no additional/variable cost. No services shall be scheduled on a federal holiday or any day the President of the United States declares a federal holiday. For a list of federal holidays, please visit: https://www.opm.gov/policy-data-oversight/pay-leave/federal-holidays/ \nThe Contractor shall document services rendered on a legible field service report and deliver to the Plant Supervisor or designee following the completion of service work. The Contractor shall sign out of the plant daily logbook, with departure time, name of technician(s), and any deviations to the planned work.  Check out is mandatory.\n\nSAFETY REQUIREMENTS: Contractor shall take such safety precautions as OSHA may determine to be reasonably necessary to protect the lives and health of occupants of the building. The Service POC/COR shall notify Contractor of any safety issues found and the action necessary to correct them. Such notice, when served on the Contractor or his representative at the work site, shall be sufficient for the corrective actions to be taken. If Contractor fails or refuses to comply promptly, the Contracting Officer may issue an order stopping all or part of the work and hold the Contractor in default.\n\nCOMPENTENCY OF SERVICE PERSONNEL:  \nAll contractor personnel shall complete  VA Privacy and Information Security Awareness and Rules of Behavior  Training at https://www.tms.va.gov/learning/user/login.jsp. The contractor shall deliver copies of the completion certificates for all contractor personnel to the Service POC/COR. The certificates shall be delivered before or at the time the personnel arrive at the VA facility. Failure to complete the mandatory annual training and sign the Privacy Training annually, within the timeframe required, is grounds for suspension or termination of all physical or electronic access privileges and removal from work on the contract until such time as the training and documents are complete.\nContractor must present the Service POC/COR copies of trainings, licenses and/or certifications for each contractor personnel that will be performing the work, within three (3) business days from the date of contract award. \nAn employee demonstrating the minimum experience level must always be physically present to supervise the task performance of lesser qualified technicians. \nThe Service POC/COR will have final approval authority related to the technical acceptability of the contractor s merits.","text":"This is a Sources Sought Notice for Reverse Osmosis Water System Maintenance Services as identified in the Statement of Work (SOW) for the Ann Arbor VA Medical Center in Ann Arbor, Michigan. The contractor shall furnish all necessary tools, parts, labor, supplies, materials, equipment, supervision and transportation necessary to furnish the services noted below.\n\nA DRAFT SOW is attached to this notice and is subject to change should a solicitation be issued as a result of this notice.\n\nPlease respond if you have the ability and actual intention to complete this requirement. All of the following information is required in your response:\n\nSAM UEI NUMBER provide this in the email text\nGSA Contract Number provide this in the email text\nCapabilities Statement\nConfirmation of actual intent to submit an offer should an RFQ be posted in future\nCompany name and address\nPoint of contact information (name, phone, email)\nSocioeconomic size status (example: large business, small business, WOSB, SDVOSB, etc.) provide this in the email text\n\nThis Sources Sought Notice is intended to locate any business capable of performance.\n\nThe anticipated NAICS Code for this requirement is 221310.\n\nThis is not a Request for Quotation and quotes shall not be reviewed at this time.\n\nThe Government shall not be responsible for any costs incurred by the contractor because of this Sources Sought Notice.\n\nThis notice shall not be construed as a commitment by the Government to ultimately award a contract, nor does it restrict the Government to any particular acquisition approach. All information submitted in response to this announcement is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government.\n\nResponses shall be submitted by email only, to Jeannie Ortiz, at jeanne.ortiz@va.gov by Monday, February 16, 2026, at 10:00 AM Eastern Time (ET). Responses MUST include 36C25026Q0271 in the subject line. PHONE CALLS SHALL NOT BE ACCEPTED FOR THIS NOTICE.\n\nDRAFT STATEMENT OF WORK\n\nGENERAL: Contractor shall provide all labor, parts, materials, personnel, transportation and\nsupervision to perform preventive maintenance and non-routine emergency maintenance services of the Reverse Osmosis (RO) Equipment Systems located at the Ann Arbor VA Medical Center (AAVA) located at 2215 Fuller Road, Ann Arbor, MI 48105.\n\nThe Reverse Osmosis (RO) Water Equipment Systems are comprised of one set of RO water systems serving Sterile Processing Service (SPS) and one set of RO water systems serving Laboratory Department (Lab).\nPreventive maintenance services consist of evaluating system components, replacing consumable system components, generating Field Service Reports and recommending corrective actions for deficiencies.\nEmergency maintenance services consist of making timely and critical repairs to reverse osmosis equipment to ensure uninterrupted operation of the process water.\n\nCONFORMANCE STANDARDS: Services provided in this contract shall conform to original\nequipment manufacturer maintenance and operation instructions, ST108 Standard, AAMI Standard 79, and AAMI TIR 34:2014 recommendations for the water quality necessary for the reprocessing of medical instruments, and all other applicable AAMI Standards.\n\nSCOPE OF WORK: The Preventive Maintenance Service shall consist of quarterly, semi-annual,\nannual visits to meet scheduled maintenance intervals. Preventive Maintenance shall be performed on the components listed below at the specified intervals and Emergency Services will be performed on an as needed basis:\n\nSterile Processing Service (SPS) Reverse Osmosis Water Systems Preventive Maintenance Services\nSPS - Preventive Maintenance Quarterly:\nReplace Hot Water Prefilter Housing (Part No.: W2T934190, Quantity: 5)\nReplace Cold Water Prefilter Housing (Part No.: W2T159682, Quantity: 5)\nReplace 20\", \"Big Blue\" Inlet Pre-Filter (Model No.: FCXBF2005, Part No.: W2T150325, Quantity: 1)\nDeliver 3.6 cu. ft. Mixed Bed Tank and Replace as indicated by monthly evaluations (Part No.: W5TDIMB10360FSP, Quantity: 1)\n\nSPS - Preventive Maintenance Semi-Annually:\nReplace 3.6 cu. ft. Carbon Tank (Part No.: W5TDIRAC0360FSP, Quantity: 1)\nReplace 10\", 0.2 Micron Filter (Model No.: FCWNF09S2, Part No.: W2T177036, Quantity: 1)\nReplace Ultraviolet Bulb (Model No.: ZCSPL3084, Part No.: W2T472870, Quantity: 2)\nReplace Ultraviolet Quartz Sleeve (Model No.: ZCSPQ3184, Part No.: W2T164367, Quantity: 2)\n\nSPS - Preventive Maintenance Annually:\nReplace Reverse Osmosis Membrane Filters (Part No. W2T844451, Quantity: 6)\nPerform Loop Sanitizing (Part No. W3TSP4707)\nReplace Filter Cartridges, 20\", 0.05um HLLW FBR UF CODE (Part No.: W2T149000, Quantity: 7)\nReplace Filter, 10\", 0.2um, Code F Pleated Vent (Part No.: W2T915015, Quantity: 1)\nReplace Filter Cap, 0.2UM 1-2 NPT (Part No.: W2T165344, Quantity: 6)\n\nLaboratory Department Reverse Osmosis Water Systems Preventive Maintenance Services\nMedica 15, Room E326 (Serial No.: ME00015946, ID No: 0013008807) Semi-Annually:\nReplace Pre-Treatment Cartridge For Small O (Part No.: W2T167305, Quantity: 1)\nReplace Filter CTRDG, Deionization DI Twin Pac (Part No.: W2T167306, Quantity: 1)\nReplace Filter Cap, In Line 0.2um (Part No.: W2T167312, Quantity: 1)\nReplace Filter, Composite Vent Air 0.2um (Part No.: W2T167303, Quantity: 1)\nReplace Cart 20 5um Code F PP String Wound (Part No.: W2T170725, Quantity: 1)\nReplace Lamp, UV 254 NM for Optn 2/4/5 Medi (Part No.: W2T167317, Quantity: 1)\nReplace RO Cartridge 7.5 LPH Flow Rate (Part No.: W2T167307, Quantity: 2)\nReplace Duplex, Pretreatment kit for Small B (Part No.: W3T185358, Quantity: 1)\nSDI React Carbon .25CF FLAT P Carbon Tank (Part No. W5TDIRAC0025FFP)\n\nEmergency Services:\nContractor shall provide the Service POC/COR with emergency telephone numbers to call in the event of an emergency. At least one of the emergency telephone numbers shall be manned twenty-four (24) hours per day, 365 days per year. This information shall be provided in writing to the Service POC/COR.\nContractor shall respond to all callbacks and be prepared to take corrective action at the site within 8 hours for all emergency service calls.\nCallbacks hours are not to take time away from preventive maintenance hours required under this contract.\nEquipment malfunctions shall be corrected the same day that the emergency service call was made. If circumstances beyond the Contractor s control preclude resolution of the problem that day, the Service POC/COR must be notified in writing with an explanation of the delay.\nAll AAMI required tests shall be performed at the conclusion of emergency work and reported in accordance with Section E.\n\nCOVERED EQUIPMENT: The following equipment and/or components shall be covered for emergency service. Contractor staff shall be qualified to service, adjust and maintain:\n\nSterile Processing Service:\nW2T164518, HOUSING FLTR INDUSTRIAL 304SS 5 RD - Prefilter Housing Qty 2\nW5TDIRAC0360FSP, SDI REACT CARBON 3.6CF FBGLS STD PO Qty 1\nW3T332697, M41RGP 3 MEMB VERT 460VAC (M41RGPV003D) Qty 1\nW5TDIMB10360FSP, SDI MIXBED1 3.6CF FBGLS STD POT Qty 1\nW2T813107, TANK,CONE BTM 500GAL PE STD Qty 1\nW2T165787, CART 10\" 0.2UM CODE F PLTD VNT Qty 1\nW2T179895, PUMP MULTI CEN 3PH 460 CRNE5-5, Qty 2\nW2T185418, Panel Qty 1\nW2T144487, UV UNIT,DISFECT MP2SL 120V/60HZ NO OPTNS; Qty 1\nW2T541231, TRANSMITTER,M800 ISM/PULSE 120VAC 4 CH; Qty 1\nW2T149000, 7 Round Ultrafilter Housing Qty 1\n\nLab Services:\nW3T317159, Kit, Leak Prevent 115 .500 No BRS VLV; Qty 1\nW2T809169, Valve, PRV .50 .25 NPT F I/O 250 PSI BRZ; Qty 1\nW2T177833, Medica 15 W/BOOSTER PUMP; Qty 1\nW2T159477, DV25 MODUL DOCK VSL 25 LIT; Qty 1\nW2T183873, BRACKET, WALL MOT 25/40L RESERV; Qty 1\nW2T169124, VALVE, SHUT OFF 0.3125 USH FIT, Qty 7\nW5TDIRAC0025FFP, Carbon Tank, Qty 1\n\nDELIVERABLE REPORTS: Contractor shall deliver legible field service reports immediately at the completion of each visit. Reports shall detail the work performed and include work technician name(s), arrival and departure times, issues found, and any deviations from planned work.\n\nREPORTING REQUIREMENTS:\nThe Contractor is required to schedule an appropriate service date with Facilities Management two weeks in advance of performance. The service dates will be subject to short notice or immediate change based on operational needs of the affected departments. The Service POC/COR will coordinate with Sterile Processing Service to minimize operational impacts and preserve the schedule as best as possible. The Service POC/COR shall have final approval of the day and time for the Preventive Maintenance.\nContractor check-in is mandatory. Contractor staff shall check-in with the Plant Supervisor or designee, located in the Energy Center, Building 32, and sign into the Plant daily logbook with arrival time, name of technician(s) and general nature of the visit.\nScheduled services will be performed during normal business hours, Monday through Friday, 8:30 am to 4:30 pm. The VA reserves the right to request certain services be performed after hours or weekends based on the needs of the facility, at no additional/variable cost. No services shall be scheduled on a federal holiday or any day the President of the United States declares a federal holiday. For a list of federal holidays, please visit: https://www.opm.gov/policy-data-oversight/pay-leave/federal-holidays/\nThe Contractor shall document services rendered on a legible field service report and deliver to the Plant Supervisor or designee following the completion of service work. The Contractor shall sign out of the plant daily logbook, with departure time, name of technician(s), and any deviations to the planned work. Check out is mandatory.\n\nSAFETY REQUIREMENTS: Contractor shall take such safety precautions as OSHA may determine to be reasonably necessary to protect the lives and health of occupants of the building. The Service POC/COR shall notify Contractor of any safety issues found and the action necessary to correct them. Such notice, when served on the Contractor or his representative at the work site, shall be sufficient for the corrective actions to be taken. If Contractor fails or refuses to comply promptly, the Contracting Officer may issue an order stopping all or part of the work and hold the Contractor in default.\n\nCOMPENTENCY OF SERVICE PERSONNEL:\nAll contractor personnel shall complete VA Privacy and Information Security Awareness and Rules of Behavior Training at https://www.tms.va.gov/learning/user/login.jsp. The contractor shall deliver copies of the completion certificates for all contractor personnel to the Service POC/COR. The certificates shall be delivered before or at the time the personnel arrive at the VA facility. Failure to complete the mandatory annual training and sign the Privacy Training annually, within the timeframe required, is grounds for suspension or termination of all physical or electronic access privileges and removal from work on the contract until such time as the training and documents are complete.\nContractor must present the Service POC/COR copies of trainings, licenses and/or certifications for each contractor personnel that will be performing the work, within three (3) business days from the date of contract award.\nAn employee demonstrating the minimum experience level must always be physically present to supervise the task performance of lesser qualified technicians.\nThe Service POC/COR will have final approval authority related to the technical acceptability of the contractor s merits.","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"36C25026Q0271","product_service_code":"J046"}],"due_at":"2026-02-16T15:00:00Z","due_date":"2026-02-16","closes_at":"2026-02-16T15:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","state":"MI","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":"description","state_evidence":"AAVA) LOCATED AT 2215 FULLER ROAD, ANN ARBOR, MI 48105","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-14T08:49:08.412Z","principal_notice_id":"08be48e86fd24f8790210281421f884c","description":{"text":"This is a Sources Sought Notice for Reverse Osmosis Water System Maintenance Services as identified in the Statement of Work (SOW) for the Ann Arbor VA Medical Center in Ann Arbor, Michigan. The contractor shall furnish all necessary tools, parts, labor, supplies, materials, equipment, supervision and transportation necessary to furnish the services noted below.\n\nA DRAFT SOW is attached to this notice and is subject to change should a solicitation be issued as a result of this notice.\n\nPlease respond if you have the ability and actual intention to complete this requirement. All of the following information is required in your response:\n\nSAM UEI NUMBER provide this in the email text\nGSA Contract Number provide this in the email text\nCapabilities Statement\nConfirmation of actual intent to submit an offer should an RFQ be posted in future\nCompany name and address\nPoint of contact information (name, phone, email)\nSocioeconomic size status (example: large business, small business, WOSB, SDVOSB, etc.) provide this in the email text\n\nThis Sources Sought Notice is intended to locate any business capable of performance.\n\nThe anticipated NAICS Code for this requirement is 221310.\n\nThis is not a Request for Quotation and quotes shall not be reviewed at this time.\n\nThe Government shall not be responsible for any costs incurred by the contractor because of this Sources Sought Notice.\n\nThis notice shall not be construed as a commitment by the Government to ultimately award a contract, nor does it restrict the Government to any particular acquisition approach. All information submitted in response to this announcement is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government.\n\nResponses shall be submitted by email only, to Jeannie Ortiz, at jeanne.ortiz@va.gov by Monday, February 16, 2026, at 10:00 AM Eastern Time (ET). Responses MUST include 36C25026Q0271 in the subject line. PHONE CALLS SHALL NOT BE ACCEPTED FOR THIS NOTICE.\n\nDRAFT STATEMENT OF WORK\n\nGENERAL: Contractor shall provide all labor, parts, materials, personnel, transportation and\nsupervision to perform preventive maintenance and non-routine emergency maintenance services of the Reverse Osmosis (RO) Equipment Systems located at the Ann Arbor VA Medical Center (AAVA) located at 2215 Fuller Road, Ann Arbor, MI 48105.\n\nThe Reverse Osmosis (RO) Water Equipment Systems are comprised of one set of RO water systems serving Sterile Processing Service (SPS) and one set of RO water systems serving Laboratory Department (Lab).\nPreventive maintenance services consist of evaluating system components, replacing consumable system components, generating Field Service Reports and recommending corrective actions for deficiencies.\nEmergency maintenance services consist of making timely and critical repairs to reverse osmosis equipment to ensure uninterrupted operation of the process water.\n\nCONFORMANCE STANDARDS: Services provided in this contract shall conform to original\nequipment manufacturer maintenance and operation instructions, ST108 Standard, AAMI Standard 79, and AAMI TIR 34:2014 recommendations for the water quality necessary for the reprocessing of medical instruments, and all other applicable AAMI Standards.\n\nSCOPE OF WORK: The Preventive Maintenance Service shall consist of quarterly, semi-annual,\nannual visits to meet scheduled maintenance intervals. Preventive Maintenance shall be performed on the components listed below at the specified intervals and Emergency Services will be performed on an as needed basis:\n\nSterile Processing Service (SPS) Reverse Osmosis Water Systems Preventive Maintenance Services\nSPS - Preventive Maintenance Quarterly:\nReplace Hot Water Prefilter Housing (Part No.: W2T934190, Quantity: 5)\nReplace Cold Water Prefilter Housing (Part No.: W2T159682, Quantity: 5)\nReplace 20\", \"Big Blue\" Inlet Pre-Filter (Model No.: FCXBF2005, Part No.: W2T150325, Quantity: 1)\nDeliver 3.6 cu. ft. Mixed Bed Tank and Replace as indicated by monthly evaluations (Part No.: W5TDIMB10360FSP, Quantity: 1)\n\nSPS - Preventive Maintenance Semi-Annually:\nReplace 3.6 cu. ft. Carbon Tank (Part No.: W5TDIRAC0360FSP, Quantity: 1)\nReplace 10\", 0.2 Micron Filter (Model No.: FCWNF09S2, Part No.: W2T177036, Quantity: 1)\nReplace Ultraviolet Bulb (Model No.: ZCSPL3084, Part No.: W2T472870, Quantity: 2)\nReplace Ultraviolet Quartz Sleeve (Model No.: ZCSPQ3184, Part No.: W2T164367, Quantity: 2)\n\nSPS - Preventive Maintenance Annually:\nReplace Reverse Osmosis Membrane Filters (Part No. W2T844451, Quantity: 6)\nPerform Loop Sanitizing (Part No. W3TSP4707)\nReplace Filter Cartridges, 20\", 0.05um HLLW FBR UF CODE (Part No.: W2T149000, Quantity: 7)\nReplace Filter, 10\", 0.2um, Code F Pleated Vent (Part No.: W2T915015, Quantity: 1)\nReplace Filter Cap, 0.2UM 1-2 NPT (Part No.: W2T165344, Quantity: 6)\n\nLaboratory Department Reverse Osmosis Water Systems Preventive Maintenance Services\nMedica 15, Room E326 (Serial No.: ME00015946, ID No: 0013008807) Semi-Annually:\nReplace Pre-Treatment Cartridge For Small O (Part No.: W2T167305, Quantity: 1)\nReplace Filter CTRDG, Deionization DI Twin Pac (Part No.: W2T167306, Quantity: 1)\nReplace Filter Cap, In Line 0.2um (Part No.: W2T167312, Quantity: 1)\nReplace Filter, Composite Vent Air 0.2um (Part No.: W2T167303, Quantity: 1)\nReplace Cart 20 5um Code F PP String Wound (Part No.: W2T170725, Quantity: 1)\nReplace Lamp, UV 254 NM for Optn 2/4/5 Medi (Part No.: W2T167317, Quantity: 1)\nReplace RO Cartridge 7.5 LPH Flow Rate (Part No.: W2T167307, Quantity: 2)\nReplace Duplex, Pretreatment kit for Small B (Part No.: W3T185358, Quantity: 1)\nSDI React Carbon .25CF FLAT P Carbon Tank (Part No. W5TDIRAC0025FFP)\n\nEmergency Services:\nContractor shall provide the Service POC/COR with emergency telephone numbers to call in the event of an emergency. At least one of the emergency telephone numbers shall be manned twenty-four (24) hours per day, 365 days per year. This information shall be provided in writing to the Service POC/COR.\nContractor shall respond to all callbacks and be prepared to take corrective action at the site within 8 hours for all emergency service calls.\nCallbacks hours are not to take time away from preventive maintenance hours required under this contract.\nEquipment malfunctions shall be corrected the same day that the emergency service call was made. If circumstances beyond the Contractor s control preclude resolution of the problem that day, the Service POC/COR must be notified in writing with an explanation of the delay.\nAll AAMI required tests shall be performed at the conclusion of emergency work and reported in accordance with Section E.\n\nCOVERED EQUIPMENT: The following equipment and/or components shall be covered for emergency service. Contractor staff shall be qualified to service, adjust and maintain:\n\nSterile Processing Service:\nW2T164518, HOUSING FLTR INDUSTRIAL 304SS 5 RD - Prefilter Housing Qty 2\nW5TDIRAC0360FSP, SDI REACT CARBON 3.6CF FBGLS STD PO Qty 1\nW3T332697, M41RGP 3 MEMB VERT 460VAC (M41RGPV003D) Qty 1\nW5TDIMB10360FSP, SDI MIXBED1 3.6CF FBGLS STD POT Qty 1\nW2T813107, TANK,CONE BTM 500GAL PE STD Qty 1\nW2T165787, CART 10\" 0.2UM CODE F PLTD VNT Qty 1\nW2T179895, PUMP MULTI CEN 3PH 460 CRNE5-5, Qty 2\nW2T185418, Panel Qty 1\nW2T144487, UV UNIT,DISFECT MP2SL 120V/60HZ NO OPTNS; Qty 1\nW2T541231, TRANSMITTER,M800 ISM/PULSE 120VAC 4 CH; Qty 1\nW2T149000, 7 Round Ultrafilter Housing Qty 1\n\nLab Services:\nW3T317159, Kit, Leak Prevent 115 .500 No BRS VLV; Qty 1\nW2T809169, Valve, PRV .50 .25 NPT F I/O 250 PSI BRZ; Qty 1\nW2T177833, Medica 15 W/BOOSTER PUMP; Qty 1\nW2T159477, DV25 MODUL DOCK VSL 25 LIT; Qty 1\nW2T183873, BRACKET, WALL MOT 25/40L RESERV; Qty 1\nW2T169124, VALVE, SHUT OFF 0.3125 USH FIT, Qty 7\nW5TDIRAC0025FFP, Carbon Tank, Qty 1\n\nDELIVERABLE REPORTS: Contractor shall deliver legible field service reports immediately at the completion of each visit. Reports shall detail the work performed and include work technician name(s), arrival and departure times, issues found, and any deviations from planned work.\n\nREPORTING REQUIREMENTS:\nThe Contractor is required to schedule an appropriate service date with Facilities Management two weeks in advance of performance. The service dates will be subject to short notice or immediate change based on operational needs of the affected departments. The Service POC/COR will coordinate with Sterile Processing Service to minimize operational impacts and preserve the schedule as best as possible. The Service POC/COR shall have final approval of the day and time for the Preventive Maintenance.\nContractor check-in is mandatory. Contractor staff shall check-in with the Plant Supervisor or designee, located in the Energy Center, Building 32, and sign into the Plant daily logbook with arrival time, name of technician(s) and general nature of the visit.\nScheduled services will be performed during normal business hours, Monday through Friday, 8:30 am to 4:30 pm. The VA reserves the right to request certain services be performed after hours or weekends based on the needs of the facility, at no additional/variable cost. No services shall be scheduled on a federal holiday or any day the President of the United States declares a federal holiday. For a list of federal holidays, please visit: https://www.opm.gov/policy-data-oversight/pay-leave/federal-holidays/\nThe Contractor shall document services rendered on a legible field service report and deliver to the Plant Supervisor or designee following the completion of service work. The Contractor shall sign out of the plant daily logbook, with departure time, name of technician(s), and any deviations to the planned work. Check out is mandatory.\n\nSAFETY REQUIREMENTS: Contractor shall take such safety precautions as OSHA may determine to be reasonably necessary to protect the lives and health of occupants of the building. The Service POC/COR shall notify Contractor of any safety issues found and the action necessary to correct them. Such notice, when served on the Contractor or his representative at the work site, shall be sufficient for the corrective actions to be taken. If Contractor fails or refuses to comply promptly, the Contracting Officer may issue an order stopping all or part of the work and hold the Contractor in default.\n\nCOMPENTENCY OF SERVICE PERSONNEL:\nAll contractor personnel shall complete VA Privacy and Information Security Awareness and Rules of Behavior Training at https://www.tms.va.gov/learning/user/login.jsp. The contractor shall deliver copies of the completion certificates for all contractor personnel to the Service POC/COR. The certificates shall be delivered before or at the time the personnel arrive at the VA facility. Failure to complete the mandatory annual training and sign the Privacy Training annually, within the timeframe required, is grounds for suspension or termination of all physical or electronic access privileges and removal from work on the contract until such time as the training and documents are complete.\nContractor must present the Service POC/COR copies of trainings, licenses and/or certifications for each contractor personnel that will be performing the work, within three (3) business days from the date of contract award.\nAn employee demonstrating the minimum experience level must always be physically present to supervise the task performance of lesser qualified technicians.\nThe Service POC/COR will have final approval authority related to the technical acceptability of the contractor s merits.","html":"This is a Sources Sought Notice for Reverse Osmosis Water System Maintenance Services as identified in the Statement of Work (SOW) for the Ann Arbor VA Medical Center in Ann Arbor, Michigan. The contractor shall furnish all necessary tools, parts, labor, supplies, materials, equipment, supervision and transportation necessary to furnish the services noted below.\n\nA DRAFT SOW is attached to this notice and is subject to change should a solicitation be issued as a result of this notice. \n\nPlease respond if you have the ability and actual intention to complete this requirement. All of the following information is required in your response:\n\nSAM UEI NUMBER   provide this in the email text\nGSA Contract Number   provide this in the email text\nCapabilities Statement\nConfirmation of actual intent to submit an offer should an RFQ be posted in future\nCompany name and address\nPoint of contact information (name, phone, email)\nSocioeconomic size status (example: large business, small business, WOSB, SDVOSB, etc.)   provide this in the email text\n\nThis Sources Sought Notice is intended to locate any business capable of performance.\n\nThe anticipated NAICS Code for this requirement is 221310.\n\nThis is not a Request for Quotation and quotes shall not be reviewed at this time.\n\nThe Government shall not be responsible for any costs incurred by the contractor because of this Sources Sought Notice.\n\nThis notice shall not be construed as a commitment by the Government to ultimately award a contract, nor does it restrict the Government to any particular acquisition approach. All information submitted in response to this announcement is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government.\n\nResponses shall be submitted by email only, to Jeannie Ortiz, at jeanne.ortiz@va.gov by Monday, February 16, 2026, at 10:00 AM Eastern Time (ET). Responses MUST include 36C25026Q0271 in the subject line. PHONE CALLS SHALL NOT BE ACCEPTED FOR THIS NOTICE.\n\nDRAFT STATEMENT OF WORK\n\nGENERAL: Contractor shall provide all labor, parts, materials, personnel, transportation and \nsupervision to perform preventive maintenance and non-routine emergency maintenance services of the Reverse Osmosis (RO) Equipment Systems located at the Ann Arbor VA Medical Center (AAVA) located at 2215 Fuller Road, Ann Arbor, MI 48105.  \n\nThe Reverse Osmosis (RO) Water Equipment Systems are comprised of one set of RO water systems serving Sterile Processing Service (SPS) and one set of RO water systems serving Laboratory Department (Lab).\nPreventive maintenance services consist of evaluating system components, replacing consumable system components, generating Field Service Reports and recommending corrective actions for deficiencies.\nEmergency maintenance services consist of making timely and critical repairs to reverse osmosis equipment to ensure uninterrupted operation of the process water.  \n \nCONFORMANCE STANDARDS: Services provided in this contract shall conform to original \nequipment manufacturer maintenance and operation instructions, ST108 Standard, AAMI Standard 79, and AAMI TIR 34:2014 recommendations for the water quality necessary for the reprocessing of medical instruments, and all other applicable AAMI Standards. \n\nSCOPE OF WORK: The Preventive Maintenance Service shall consist of quarterly, semi-annual, \nannual visits to meet scheduled maintenance intervals. Preventive Maintenance shall be performed on the components listed below at the specified intervals and Emergency Services will be performed on an as needed basis: \n\nSterile Processing Service (SPS)   Reverse Osmosis Water Systems Preventive Maintenance Services\nSPS - Preventive Maintenance   Quarterly:\nReplace Hot Water Prefilter Housing (Part No.: W2T934190, Quantity: 5)\nReplace Cold Water Prefilter Housing (Part No.: W2T159682, Quantity: 5)  \nReplace 20\", \"Big Blue\" Inlet Pre-Filter (Model No.: FCXBF2005, Part No.: W2T150325, Quantity: 1)\nDeliver 3.6 cu. ft. Mixed Bed Tank and Replace as indicated by monthly evaluations (Part No.: W5TDIMB10360FSP, Quantity: 1) \n\nSPS - Preventive Maintenance   Semi-Annually:\nReplace 3.6 cu. ft. Carbon Tank (Part No.: W5TDIRAC0360FSP, Quantity: 1)\nReplace 10\", 0.2 Micron Filter (Model No.: FCWNF09S2, Part No.: W2T177036, Quantity: 1)\nReplace Ultraviolet Bulb (Model No.: ZCSPL3084, Part No.: W2T472870, Quantity: 2)\nReplace Ultraviolet Quartz Sleeve (Model No.: ZCSPQ3184, Part No.: W2T164367, Quantity: 2)\n\nSPS - Preventive Maintenance   Annually:\nReplace Reverse Osmosis Membrane Filters (Part No. W2T844451, Quantity: 6)\nPerform Loop Sanitizing (Part No. W3TSP4707)\nReplace Filter Cartridges, 20\", 0.05um HLLW FBR UF CODE (Part No.: W2T149000, Quantity: 7)\nReplace Filter, 10\", 0.2um, Code F Pleated Vent (Part No.: W2T915015, Quantity: 1)\nReplace Filter Cap, 0.2UM 1-2 NPT (Part No.: W2T165344, Quantity: 6)\n\nLaboratory Department   Reverse Osmosis Water Systems Preventive Maintenance Services\nMedica 15, Room E326 (Serial No.: ME00015946, ID No: 0013008807) Semi-Annually: \nReplace Pre-Treatment Cartridge For Small O (Part No.: W2T167305, Quantity: 1)\nReplace Filter CTRDG, Deionization DI Twin Pac (Part No.: W2T167306, Quantity: 1)\nReplace Filter Cap, In Line 0.2um (Part No.: W2T167312, Quantity: 1)\nReplace Filter, Composite Vent Air 0.2um (Part No.: W2T167303, Quantity: 1)\nReplace Cart 20  5um Code F PP String Wound (Part No.: W2T170725, Quantity: 1)\nReplace Lamp, UV 254 NM for Optn 2/4/5 Medi (Part No.: W2T167317, Quantity: 1)\nReplace RO Cartridge 7.5 LPH Flow Rate (Part No.: W2T167307, Quantity: 2)\nReplace Duplex, Pretreatment kit for Small B (Part No.: W3T185358, Quantity: 1)\nSDI React Carbon .25CF FLAT P   Carbon Tank (Part No. W5TDIRAC0025FFP)\n\nEmergency Services:\nContractor shall provide the Service POC/COR with emergency telephone numbers to call in the event of an emergency. At least one of the emergency telephone numbers shall be manned twenty-four (24) hours per day, 365 days per year. This information shall be provided in writing to the Service POC/COR.\nContractor shall respond to all callbacks and be prepared to take corrective action at the site within 8 hours for all emergency service calls.\nCallbacks hours are not to take time away from preventive maintenance hours required under this contract. \nEquipment malfunctions shall be corrected the same day that the emergency service call was made. If circumstances beyond the Contractor s control preclude resolution of the problem that day, the Service POC/COR must be notified in writing with an explanation of the delay. \nAll AAMI required tests shall be performed at the conclusion of emergency work and reported in accordance with Section E. \n\nCOVERED EQUIPMENT: The following equipment and/or components shall be covered for emergency service. Contractor staff shall be qualified to service, adjust and maintain: \n\nSterile Processing Service:\nW2T164518, HOUSING FLTR INDUSTRIAL 304SS 5 RD - Prefilter Housing Qty 2\nW5TDIRAC0360FSP, SDI REACT CARBON 3.6CF FBGLS STD PO Qty 1 \nW3T332697, M41RGP 3 MEMB VERT 460VAC (M41RGPV003D) Qty 1 \nW5TDIMB10360FSP, SDI MIXBED1 3.6CF FBGLS STD POT Qty 1 \nW2T813107, TANK,CONE BTM 500GAL PE STD Qty 1 \nW2T165787, CART 10\" 0.2UM CODE F PLTD VNT Qty 1 \nW2T179895, PUMP MULTI CEN 3PH 460 CRNE5-5, Qty 2 \nW2T185418, Panel Qty 1 \nW2T144487, UV UNIT,DISFECT MP2SL 120V/60HZ NO OPTNS; Qty 1 \nW2T541231, TRANSMITTER,M800 ISM/PULSE 120VAC 4 CH; Qty 1 \nW2T149000, 7 Round Ultrafilter Housing Qty 1 \n\nLab Services:\nW3T317159, Kit, Leak Prevent 115 .500  No BRS VLV; Qty 1\nW2T809169, Valve, PRV .50  .25  NPT F I/O 250 PSI BRZ; Qty 1\nW2T177833, Medica 15 W/BOOSTER PUMP; Qty 1\nW2T159477, DV25 MODUL DOCK VSL 25 LIT; Qty 1\nW2T183873, BRACKET, WALL MOT 25/40L RESERV; Qty 1\nW2T169124, VALVE, SHUT OFF 0.3125  USH FIT, Qty 7\nW5TDIRAC0025FFP, Carbon Tank, Qty 1\n\nDELIVERABLE REPORTS: Contractor shall deliver legible field service reports immediately at the completion of each visit. Reports shall detail the work performed and include work technician name(s), arrival and departure times, issues found, and any deviations from planned work.\n\nREPORTING REQUIREMENTS: \nThe Contractor is required to schedule an appropriate service date with Facilities Management two weeks in advance of performance. The service dates will be subject to short notice or immediate change based on operational needs of the affected departments. The Service POC/COR will coordinate with Sterile Processing Service to minimize operational impacts and preserve the schedule as best as possible. The Service POC/COR shall have final approval of the day and time for the Preventive Maintenance. \nContractor check-in is mandatory. Contractor staff shall check-in with the Plant Supervisor or designee, located in the Energy Center, Building 32, and sign into the Plant daily logbook with arrival time, name of technician(s) and general nature of the visit. \nScheduled services will be performed during normal business hours, Monday through Friday, 8:30 am to 4:30 pm. The VA reserves the right to request certain services be performed after hours or weekends based on the needs of the facility, at no additional/variable cost. No services shall be scheduled on a federal holiday or any day the President of the United States declares a federal holiday. For a list of federal holidays, please visit: https://www.opm.gov/policy-data-oversight/pay-leave/federal-holidays/ \nThe Contractor shall document services rendered on a legible field service report and deliver to the Plant Supervisor or designee following the completion of service work. The Contractor shall sign out of the plant daily logbook, with departure time, name of technician(s), and any deviations to the planned work.  Check out is mandatory.\n\nSAFETY REQUIREMENTS: Contractor shall take such safety precautions as OSHA may determine to be reasonably necessary to protect the lives and health of occupants of the building. The Service POC/COR shall notify Contractor of any safety issues found and the action necessary to correct them. Such notice, when served on the Contractor or his representative at the work site, shall be sufficient for the corrective actions to be taken. If Contractor fails or refuses to comply promptly, the Contracting Officer may issue an order stopping all or part of the work and hold the Contractor in default.\n\nCOMPENTENCY OF SERVICE PERSONNEL:  \nAll contractor personnel shall complete  VA Privacy and Information Security Awareness and Rules of Behavior  Training at https://www.tms.va.gov/learning/user/login.jsp. The contractor shall deliver copies of the completion certificates for all contractor personnel to the Service POC/COR. The certificates shall be delivered before or at the time the personnel arrive at the VA facility. Failure to complete the mandatory annual training and sign the Privacy Training annually, within the timeframe required, is grounds for suspension or termination of all physical or electronic access privileges and removal from work on the contract until such time as the training and documents are complete.\nContractor must present the Service POC/COR copies of trainings, licenses and/or certifications for each contractor personnel that will be performing the work, within three (3) business days from the date of contract award. \nAn employee demonstrating the minimum experience level must always be physically present to supervise the task performance of lesser qualified technicians. \nThe Service POC/COR will have final approval authority related to the technical acceptability of the contractor s merits.","origin":"detail"},"contacts":[{"name":"Jeannie Ortiz","role":"primary","email":"jeanne.ortiz@va.gov","phone":"NO PHONE CALLS ACCEPTED","title":"Contracting Officer"}],"place_of_performance":null,"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"naics_codes":["221310"],"award":{"awardee":{}},"attachments":[{"resource_id":"ae3e591e07b24ea7a15f4e8236252b81","name":"36C25026Q0271.docx","kind":"file","mime_type":".docx","size_bytes":36188,"posted_at":"2026-01-30T15:13:52.975Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/ae3e591e07b24ea7a15f4e8236252b81/download","mirrored":false}],"awards":[],"related":[{"key":"36C25027Q0014","latest_notice_id":"b13cc87179e947e7b42da2de44a6bde1","title":"J061--541 Electrical Power Distribution Equipment Testing, Inspection, and Maintenance - VAMC Cleveland","solicitation_number":"36C25027Q0014","notice_type":"k","first_type":"k","first_posted":"2026-10-09","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"238210","psc":"J061","set_aside":"SBA","state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C25027Q0123","latest_notice_id":"fb53a332644a4c8fa983bf28c8643d2d","title":"S222--Sources Sought - Hazardous Waste Removal/Disposal Northeast Ohio VA Healthcare System - Cleveland, OH","solicitation_number":"36C25027Q0123","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T18:30:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"562112","psc":"S222","set_aside":null,"state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C25027B0009","latest_notice_id":"85b83d408f1f422885991142c2734b45","title":"Z1DA--FY27 NRM - VISN Base Modernize Nurse Call - 539-23-101","solicitation_number":"36C25027B0009","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"},{"key":"36C25027B0008","latest_notice_id":"5afe716a38494a6f84b1e84205805f86","title":"Z1DA--FY27 NRM - VISN Base Install Roof Equipment Railings - 539-22-206","solicitation_number":"36C25027B0008","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"},{"key":"36C25027B0005","latest_notice_id":"2cb4a6354be04cc89c5d6125945b1892","title":"Z1DA--***FY27 Requirement*** First Floor X Ray - Room CC157 553-CSI-022","solicitation_number":"36C25027B0005","notice_type":"p","first_type":"p","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"MI","county":"26163","county_name":"Wayne County","city":"2622000","city_name":"Detroit","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"}],"similar_open":[{"key":"FA489727Q0004","latest_notice_id":"1be2f54051d749f3b3104d953c98156d","title":"Re-Activation of Snake River Water Pump","solicitation_number":"FA489727Q0004","notice_type":"k","first_type":"k","first_posted":"2026-11-09","last_posted":"2026-11-09","notices":1,"due_at":"2026-11-30T17:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA4897","office_name":"FA4897 366 CONS PKP","naics":"221310","psc":"S114","set_aside":"SBA","state":"ID","county":"16039","county_name":"Elmore County","city":"1654820","city_name":"Mountain Home AFB","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-10T04:49:28.155858Z"},{"key":"15B70027PR000089","latest_notice_id":"c912d189d7364c8b890f9ca51c716824","title":"Water Treatment Chemicals, Testing, Monitoring, and Reporting- Sources Sought Notice / Request for Information","solicitation_number":"15B70027PR000089","notice_type":"r","first_type":"r","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":"2026-12-03T16:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-015","dept_name":"JUSTICE, DEPARTMENT OF","sub_key":"s-1540","sub_name":"FEDERAL PRISON SYSTEM / BUREAU OF PRISONS","office_key":"o-15BNAS","office_name":"NATIONAL ACQUISITIONS - CO","naics":"221310","psc":"J046","set_aside":null,"state":"DC","county":"11001","county_name":"District of Columbia","city":"1150000","city_name":"Washington","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"36C26227Q0106","latest_notice_id":"8a66540d3bab41f083edb813277fdeae","title":"H246--Reverse Osmosis, Deionization Equipment and PE Water Softene 2026-2027","solicitation_number":"36C26227Q0106","notice_type":"o","first_type":"r","first_posted":"2026-11-06","last_posted":"2026-11-23","notices":2,"due_at":"2026-12-04T19:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"221310","psc":"H246","set_aside":null,"state":"CA","county":"06037","county_name":"Los Angeles County","city":"0643000","city_name":"Long Beach","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"}],"similar_open_total":6,"indexable":false}