{"canonical":"https://sealedbidder.com/opportunities/36c25026q0018","key":"36C25026Q0018","url":"https://sealedbidder.com/opportunities/36c25026q0018","title":"J041--Chiller Plant Maintenance - Louis Stokes Cleveland VAMC","solicitation_number":"36C25026Q0018","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-09-12T18:00:00Z","first_posted":"2025-08-29","last_posted":"2025-08-29","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"811310","psc":"J041","set_aside":null,"place_state":"OH","place_scope":"site","site":"Cleveland VA Medical Center","place_state_source":null,"place_evidence":null,"place_county":"39035","place_county_name":"Cuyahoga County","place_city":"3916000","place_city_name":"Cleveland","winner":null,"award_amount":null,"publications":[{"notice_id":"1b47eb37f6cd41f99a3ea9641897ba0e","title":"J041--Chiller Plant Maintenance - Louis Stokes Cleveland VAMC","solicitation_number":"36C25026Q0018","notice_type":"r","base_type":"r","posted":"2025-08-29","posted_at":"2025-08-29T19:06:16.621Z","due_at":"2025-09-12T18:00:00Z","due_date":"2025-09-12","cancelled":false,"archived":true,"archive_date":"2025-11-11","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/1b47eb37f6cd41f99a3ea9641897ba0e/view","enriched":true,"history":[{"index":3,"title":"J041--Chiller Plant Maintenance - Louis Stokes Cleveland VAMC","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-29T19:06:16.621Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"1b47eb37f6cd41f99a3ea9641897ba0e","solicitation_number":"36C25026Q0018"}]}],"latest_notice_id":"1b47eb37f6cd41f99a3ea9641897ba0e","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-08-29","posted_at":"2025-08-29T19:06:16.621Z","created_at":"2025-08-29T19:06:14.394Z","modified_at":"2025-11-12T04:55:46.985Z","response_deadline":{"raw":"2025-09-12T14:00:00-04:00","utc":"2025-09-12T18:00:00Z","date":"2025-09-12","time":"14:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/1b47eb37f6cd41f99a3ea9641897ba0e/view"},"naics":{"codes":["811310"],"primary":"811310"},"title":"J041--Chiller Plant Maintenance - Louis Stokes Cleveland VAMC","agency":{"office":{"code":"36C250","name":"250-NETWORK CONTRACT OFFICE 10 (36C250)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"organization_id":"100167099","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-11-11","archive_type":"auto_custom"},"history":[{"index":3,"title":"J041--Chiller Plant Maintenance - Louis Stokes Cleveland VAMC","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-29T19:06:16.621Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"1b47eb37f6cd41f99a3ea9641897ba0e","solicitation_number":"36C25026Q0018"}],"contacts":[{"name":"Chad Kemper","role":"primary","email":"chad.kemper@va.gov","phone":"(937) 268-6511 ext. 4541","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"1b47eb37f6cd41f99a3ea9641897ba0e","lineage_id":"1b47eb37f6cd41f99a3ea9641897ba0e","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-02T00:06:02.891253879Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"251368e6e307660f19f00b29557a6d3cf841e5f39e6645b4ba7ed89a6240c4f3","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-02T00:06:02.891253879Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Sources Sought Notice\n\nPage 4 of 4\n\n*= Required Field\nSources Sought Notice\n\nPage 1 of 4\nDepartment of Veterans Affairs\nSources Sought Notice   Chiller Plant Maintenance   Louis Stokes Cleveland VA Medical Center\n\nThis is a Sources Sought notice and not a request for quotes. This request is solely for the purpose of conducting market research to enhance VHA s understanding of the market s offered products, services and capabilities. The Government will not pay any costs for responses submitted in response to this Sources Sought.\nThe Department of Veterans Affairs (VA), VA Healthcare System, Network Contracting Office (NCO) 10, on behalf of Louis Stokes Cleveland VA Medical Center in Cleveland, Ohio, is conducting market research through this sources sought notice to seek sources that can provide Chiller Plant Maintenance and Services for the Louis Stokes Cleveland VA Medical Center.\n \nThe NAICS Code for this acquisition is 811310, size standard of $12,500,000. The product service code is J041. The contracting office is contemplating award of a Firm-Fixed-Price contract for this service.\n\nThis Sources Sought notice provides an opportunity for respondents to submit their notice of ability, and their available services in response to the requirement described below. Vendors are being invited to submit information relative to their potential of fulfilling the requirement below, in the form of a capability response that addresses the specific requirement identified in this Sources Sought. Pursuant to FAR Part 10, Market Research, the purpose of this notice is to determine if sources capable of satisfying the agency's requirements exists and to determine the commercial practices of company's engaged in providing the needed service. Pursuant to FAR Part 6 and FAR Part 19, competition and set-aside decisions may be based on the results of this market research. This notice in no way obligates the Government to any further action.\n\nThis is a \"REQUEST FOR INFORMATION\" only. Requests for a solicitation will not receive a response.\n\nDESCRIPTION\nThe Louis Stokes VA Medical Center located at 10701 East Blvd, Cleveland, Ohio 44106 is seeking a qualified contractor to provide all labor, materials, equipment, transportation, and supervision necessary to provide full-service, on-site Chiller Plant Maintenance to maintain and service all chillers, pumps, cooling towers, VFDs, and building automation controls necessary to cool and de-humidify the Medical Center for the health and safety of our patients, staff, medical equipment and visitors.\n\nGENERAL REQUIREMENTS\nPlease provide the requested information with any responses:\n\n1. Company Name and POC information.\n2. SAM.gov UEI number.\n3. GSA contract number if these services are offered on Federal Supply Schedule. \n4. Socioeconomic category (SDVOSB, VOSB, WOSB, 8a, Small Business or Large Business). If this contract is set-aside, it will be subject to the Limitations on Subcontracting rules per FAR 52.219-14, 13 CFR 125.6 and VAAR 852.219-75.\n5. Please provide a capability statement that addresses the organization s qualifications and ability to perform as a contractor for the work described below.\n6. Statement ensuring any licenses, insurances, training, certifications, or special accommodations necessary to perform this task will be met. If there are specific requirements, please provide rationale.\n7. Any questions, comments, or concerns, that may otherwise assist us.\n\nRESPONSE COMMITMENT\nPlease send all inquiries to: chad.kemper@va.gov. Phone calls will not be accepted.\n\nEligibility in participating in a future acquisition does not depend upon a response to this notice.\n?.## STATEMENT OF WORK (SOW)\n\nContract Title\n\nChiller Plant Maintenance\n\nBackground\n\nThe Louis Stokes VA Medical Center located at 10701 East Blvd, Cleveland, Ohio 44106 is seeking a qualified contractor to provide all labor, materials, equipment, transportation, and supervision necessary to provide full-service, on-site Chiller Plant Maintenance to maintain and service all chillers, pumps, cooling towers, VFDs, and building automation controls necessary to cool and de-humidify the Medical Center for the health and safety of our patients, staff, medical equipment and visitors.\n\nScope\n\nThe vendor shall supply all labor, materials, equipment, clean up, transportation, and supervision necessary to perform all full-service, on-site maintenance, repairs, and replacement as scheduled and needed to the chiller plant chillers, cooling towers, pumps and any auxiliary equipment located at Louis Stokes Cleveland VA Medical Center to maintain the equipment in full operational status. This will include all equipment listed in Parts One, Two, Three, Four and Five. Vendor will have documented certified technicians and the ability to provide repair and replacement parts.\n\nThe Louis Stokes Cleveland VA Medical Center is expecting to add an additional/new chiller during Fiscal Year 2026. The new Chiller will be added to the scope of the contract.\n\nSpecific Tasks\n\nSee equipment list and maintenance description below:\n\n5.1. Task 1: Part One - Centrifugal Chillers\n\nNUMBER\nMFG\nMODEL\n\nTONS/ OUTPUT\n\nCH-I\nTRANE\nCVHF128NA\n1,200\n4160V\nCH-2\nTRANE\nCVHF128NA\n1,200\n4160V\nCH-3\nTRANE\nCVHF128NA\n1 ,200\n4160V\nCH-4\nTRANE\nCVHF1280\n1,200\n480V\nCH-5\nTRANE\nCVHF13DFA\n1,200\n480V\n\n5.1.1. Requirements for Centrifugal Chillers and Rotary Chillers:\n\nANNUAL Maintenance\n\nOnce a year, thorough preventative maintenance will be performed, including the following:\n\nFurnish oil filters and gaskets as required.\n\nPressure test as required using system pressure.\n\nRepair any leaks. Provide refrigerant leak reports to owners as required by EPA guidelines.\n\nDetailed inspection of purge system and thorough cleaning of purge compressor, purge oil separator, purge drum. Detailed inspection of purge system to include control circuit diagnostics, purge tank checkout and water removal, replace filter drier cores and clean the air-cooled condenser, if applicable.\n\nCheck the condition of contacts for wear, pitting, etc.\n\nCheck and calibrate safety controls, including all transmitters, flow meters, and all other monitoring devices.\n\nMeg compressor motor and oil pump. Check main starters and perform recommended testing (this includes all the chillers).\n\nCheck the main starters, tighten all starter terminals, and check contacts for wear.\n\nCheck overloads.\n\nTighten motor terminals and control panel terminals.\n\nClean oil strainer, replace filter and gasket where required. Tighten oil heater leads.\n\nCheck operation of vane position. Take oil sample and have analyzed for acid, moisture, and wear metal content.\n\nChange oil when so indicated by oil analysis unless done on annual schedule. \n\nProvide yearly recommended maintenance on refrigerant monitor along with calibration test, if applicable.\n\nReport any noted deficiencies. \n\nMonthly Maintenance: \n\nMonthly inspections to be made during the operating season, to include the following:\n\nAdjust operating and safety controls. Record settings.\n\nComplete operating log of temperatures, pressures, and voltages.\n\nChange oil in purge vacuum pumps when required.\n\nCheck operation of purge system.\n\nCheck operation of control circuit.\n\nCheck operating of lubricant system including oil pump and oil pressure regulator.\n\nCheck operation of motor and starter.\n\nCheck customer log with the operator, discuss operation of the machine generally.\n\nReport to operator any uncorrected deficiencies noted.\n\nMake operating log of temperatures, pressures, voltages, amperages, etc.\n\nCheck and adjust operating and safety controls.\n\nCheck operation of oil reservoir sump heater.\n\nCheck oil level and add as required.\n\nCheck operation of control circuit.\n\nCheck operating log with operator, discuss operation of the machine generally.\n\nCheck operation of motor and starter. \n\nSeasonal Start Up\n\nThe contractor will advise regarding the start of the month. \n \n1. Test motor (Meg). \n \n2. Start the machine, check controls, and calibrate. \n \n3. Complete operating log and record settings monthly. \n \n4. Check refrigerant and oil levels. \n \n5. Check purge operation. \n \n6. Check starter operation, voltage, and current. \n\nSet up operating log with operator, instruct, and advise troubleshooting techniques. \n \nAnalysis Services\n\nVarious diagnostic tests are to be performed depending on equipment duty and type. Reports with interpretation and recommendations are to be included. \n\n1. Oil sample and analysis for wear metals, acid content, and moisture. Sample to be taken two (2) times per year. \n\n2. Refrigerant analysis for acid and moisture content (as required). \n\nAnnual Operator Training\n\nTraining of operators or building engineers on the equipment covered, if required. \n\n1. Eight (8) hours of training per year for every boiler plant employee, up to 16 employees. \n\n2. Any un-utilized training costs will be reimbursed. \n\nParts Replacement\n\nAll parts needed to replace failed components on non-covered equipment will be offered at a discount percentage (30%). This does not include materials or components, such as refrigerant, oil, and other materials the contractor will provide to perform maintenance and repairs as emergencies or scheduled under annual maintenance, monthly maintenance, seasonal start up and analysis services.\n\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\nWritten Reports:\n\nProvided to customer representative following each regular inspection or emergency call. \n\n5.2. Task 2: Part Two   Trace Automation & Controls\n\n5.2.1. Requirements for Tracer Automation Equipment Main Plant and Process Chiller Plant:\n\nA. Contractor will provide full-service coverage for regular systematic maintenance and parts, materials and labor for repairs, including all software support, defects in materials or manufacture, or due to normal wear and tear.\n\nB. Contractor will provide and install any new operational software and/or graphics with the latest revisions over the course of the contract.\n\nC. Unit maintenance and repair/replacement of PCs, Monitors, UPSs and associated equipment will be the liability of the contractor over the duration of the contract with no additional cost.\n \nD. Scheduled maintenance includes diagnosis of system performance, inspection, cleaning, adjustments, and other procedures as required by specifications according to system use and configuration.\n\nSemi-Annual Preventative Maintenance\n\nMaintenance/repair or replacement if required of the Building Automation Systems. Includes all operated valves, programming panels, BCU s, Tracer Output/Input panels and workstations associated with Energy Center equipment and operations, to include the following: \n\nMaster Station\n\nCheck the operating environment and clean the console. Check and clean the central processing unit and record input voltage.\n\n2. If necessitated by operational difficulties, run system diagnostics. Contractor will provide and install any new operational software and/or graphics with the most current version at no cost over the course of the contract.\n\n3. Clean and maintain BCU modules in both the Penthouse and Ambulatory Care.\n\n4. Check and clean CRTs and Printers.\n\n5. Perform complete system backup.\n\n6. Remote Stations and Field Hardware:\n\nVerify regulated power assembly and battery voltages, adjust as required.\n\nInspect cabinet at earth ground potential.\n\nVerify proper system electrical ground isolation.\n\nInspect interconnecting cables and electrical connections. \n\n Via terminal exercise-controlled devices with manual command functions and verify proper response of connected field hardware. \n\nCheck for alarms and overrides. Note specific alarm and override conditions for review with the owner personnel. \n\nClean external surfaces of the panel enclosure and associated field equipment units.\n \nReview system performance with Medical Centers designated contact.\n\nDiscuss specific parameter changes implemented as required.\n\nInspect interior surfaces and components of the panel enclosure and associated field equipment. \n\nEnsure all mounted devices add plug in components are securely in place. \n\nEvaluate binary and analog points for proper operation and reporting Perform a general performance review of all points. \n\nCheck individual critical points. Determine new or revised calibration coefficients as required. \n\nRecord any parameter values which are different than those shown on program listings. \n\nANNUAL OPERATOR TRAINING\n\nThe contractor will provide up to eight (8) hours of Tracer Summit on-site customer training, if requested.\n\nWRITTEN REPORTS\n\nProvided written reports to COR following each regular inspection or emergency call. \n\n5.3. Task 3: Part Three   Chill Water/Tower Water Pumps, & Drives\nNUMBER\nMFG\nMODEL\nSERVICE\n\n\nCWP-I\nWEINMAN\n444TT\nCHILLED WATER\n2400GPM\n150HP\nCWP-2\nWEINMAN\n444TT\nCHILLED WATER\n2400GPM\n150HP\nCWP-3\nWEINMAN\n444TT\nCHILLED WATER\n2400GPM\n150HP\nCWP-4\nWEINMAN\n444TT\nCHILLED WATER\n2400GPM\n150HP\nCWP-5\nPACO\n444TT\nCHILLED WATER\n2400GPM\n150HP\nCWP-6\nPACO\n444TT\nCHILLED WATER\n2400GPM\n150HP\nVFD CWP-1\nDANFOSS/ GRAHAM\nVLT6000H190\nCHILLED WATER\n\n480V\nVFD CWP-2\nDANFOSS/ GRAHAM\nVLT6000H190\nCHILLED WATER\n\n480V\nVFD CWP-3\nDANFOSS/ GRAHAM\nVLT6000H190\nCHILLED WATER\n\n480V\nVFD CWP-4\nHONEYWELL\nSMART VFD\nHVFDSD3C1500G100\nCHILLED WATER\n\n480V\nVFD CWP-5\nEATON\nCFX9000\nCHILLED\nWATER\n\n480V\nVFD CWP-6\nEATON\nSVX9000\nCHILLED\nWATER\n\n480V\nTWP-I\nWEINMAN\n12L2\nTOWER\nWATER\n3600GPM\n100HP\nTWP-2\nWEINMAN\n12102\nTOWER\nWATER\n3600GPM\n100HP\nTWP-3\nWEINMAN\n12L2\nTOWER\nWATER\n3600GPM\n100HP\nTWP-4\nWEINMAN\n12L2\nTOWER\nWATER\n3600GPM\n100HP\nTWP-5\nPACO\nKP8012-56\nTOWER\nWATER\n3600GPM\n100HP\nTWP-6\nPACO\n8012\nTOWER\nWATER\n3600GPM\n100HP\nVFD-TWP-1\nDANFOSS/ GRAHAM\nMCD3075\nTOWER\nWATER\n\n480V\nVFD-TWP-2\nDANFOSS/ GRAHAM\nMCD3075\nTOWER\nWATER\n\n480V\nVFD-TWP-3\nDANFOSS/ GRAHAM\nMCD3075\nTOWER\nWATER\n\n480V\nVFD-TWP-4\nEATON\nSVX9000\nTOWER\nWATER\n\n480V\nVFD-TWP-5\nEATON\nCFX9000\nTOWER\nPUMP\n\n480V\nVFD-TWP-6\nEATON\nSVX9000\nTOWER\nPUMP\n\n480V\n\n\n5.3.1. Requirements for all Chill-Water, Tower/Condenser Water Pumps:\n\nMonthly Maintenance\n\nMonthly inspections to be made during the operating season, to include the following:\n\n1. Lubricate pump bearings per manufacturer s recommendations.\n\n2. Lubricate motor bearings per manufacturer s recommendations.\n\n3. Check the suction and discharge pressures.\n\n4. Check packing or mechanical seal and adjust as necessary.\n\n5. Check motor voltage and amperage. \n\nSEASONAL START UP\n\n1. Clean pump strainers.\n\n2. Lubricate pump bearings per manufacturer s recommendations.\n\n3. Lubricate motor bearings per manufacturer s recommendations.\n\n4. Tighten all nuts and bolts. Check motor mounts and vibration pads.\n\n5. Visually check pump alignment and coupling.\n\n6. Check motor operating conditions.\n\n7. Inspect electrical connections and contractors.\n\n8. check mechanical seals or pump packing.\n\n9. Operate pumps and check efficiency. \n \nPARTS REPLACEMENT\n\nAll parts or failed components of the equipment needed to be replaced will be provided by the vendor/contractor. This includes all materials or components, such as refrigerant, oil, and other materials the Contractor will provide to perform maintenance and repairs as scheduled under monthly maintenance and seasonal start up.\n\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\nWRITTEN REPORTS\n\nProvided to customer representative following each regular inspection or emergency call. \n\n5.3.2. Requirements for Adjustable or Variable Frequency Drives\n\nANNUAL MAINTENANCE: Once a year a thorough preventative maintenance schedule will be performed including the following: \n\nBase year   initial base line reading of all VFDs will be provided in written report and subsequent yearly reports will be provided.\n\nRemove all debris, dust, or residue material from the drive enclosure.\n\nClean printed circuit boards with an approved cleaner or small brush.\n\nInspect for any lose plugs or ribbon cables.\n\nInspect for any damaged or missing items.\n\nLook for any overheated or charred components.\n\nLook for discolored components, smudges, or smoke residue.\n\nTighten all connections.\n\nInspect cooling fans for proper operation and change filters quarterly.\n\nCheck the continuity of all control circuit fuses.\n\nPerform diode test of the diode bridges.\n\nPerform continuity check of Debus and bus caps.\n\nPerform diode test of transistors.\n\nCheck and record AC line voltage.\n\nCheck and record motor output lead voltage for balanced supply.\n\nCheck and record Debus voltage.\n\nCompare data with previous tests to expose degradation of components.\n\nPART REPLACEMENT\n\nAll parts needed to replace failed components of the equipment will be provided by the contractor. This includes all materials or components, such as refrigerant, oil, and other materials the Contractor will provide to perform maintenance and repairs as scheduled under annual maintenance.\n\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\n5.4. Task 4: Part Four   Cooling Towers, Cooling Tower Fan Drives, Semi-Annual Tower Cleaning, & Disinfection\n\nNUMBER\nMFG\nMODEL\nTONS\nMOTOR\n\nCT-I\nEVAPCO\nREP 224-018\n1200TONS\n2CELLS\n\nCT-2\nEVAPCO\nREP 224-018\n1200TONS\n2CELLS\n\nCT-3\nEVAPCO\nREP 224-018\n1200TONS\n2CELLS\n\nCT-4\nEVAPCO\nREP224-118\n1200TONS\n2CELLS\n\nCT-5\nEVAPCO\nAT224-118\n1200TONS\n2CELLS\n\nVFD-CT-I\nHONEYWELL SMART VFD\nHVFOSD306005100\nCOOLING TOWER\nFANS\n30\n60HZ\nVFD-CT-2\nDANFOSS/ GRAHAM\nVLT6000\nCOOLING TOWER\nFANS\n30\n60HZ\nVFD-CT-3\nDANFOSS/ GRAHAM\nVLT6000\nCOOLING\nTOWER\nFANS\n2 @ 30EA\n60HZ\nVFD-CT-4B\nEATON\nCFX9000\nCOOLING\nTOWER\nFAN\n1\n\n30HZ\nVFD-CT4A\nHONEYWELL\nNXS0300A1001\nCOOLING TOWER FAN\n1\n30HZ\nVFD-CT-5\nEATON\nSVX9000\nFANS\n2\n60HZ\n\n5.4.1. Requirements for Cooling Towers/Fluid Coolers\n\nMONTHLY MAINTENANCE\n\nMonthly inspections are to be made during the operating season, to include the following: \n\nInspect the fan, motor, and belt. Check the oil level and add oil as needed.\n\nCheck the intake strainer on cooling towers.\n\nCheck operating conditions. Adjust as required. \n\nCLEANING & DISINFECTION PROCESS\n\nTo be completed in early Spring (March/April) and late Fall (October/November) dependent on weather conditions and scheduled through the COR.\n\nThe following stages highlight the general approach for cleaning and disinfection of cooling water systems. Certain modifications may be required depending on system access, design, operation or the like. All stages in the clean and disinfection process shall require assistance from the Customer such as the operation engineer who is familiar with the system. All supplies and PPE will be contractor supplied. Proper LOTO will be utilized as needed.\n\nStage I\n\nPre-Clean Disinfection for the destruction of biofilms and pathogens\n\nAll cooling tower fans must be shut OFF and proper LOTO procedures in place prior to start of process, and all recirculation pumps must be ON.\n\nThe system is disinfected using an oxidizing biocide such as chlorine or an equivalent chemistry.\n\nA bio dispersant may also be added to help remove organic deposits and \nenhance disinfection.\n\nStage II\n\nMechanical Cleaning for surface sanitation and removal of deposits\nEach system cell and/or sump is isolated and drained for mechanical cleaning.\n\nEach system cell is pressure washed from top to bottom, internal and external, as is reasonably accessible to remove deposits.\n\nExceptional care is taken to remove deposits without damaging the fill pack.\n\nDeposits, including the sump if included in the scope, are removed for disposal. The Customer shall assist with disposal in the appropriate dumpsters or equivalents.\n\nStage III\n\nPost-Clean Disinfection for the destruction of dislodged biofilms and pathogens.\n\nAll cooling tower fans must be shut OFF, and all recirculation pumps must be ON.\n\nThe system is disinfected using an oxidizing biocide such as chlorine or equivalent chemistry.\n\nThe full water treatment program must be immediately resumed following the disinfection step to re-passivate system metallurgy.\n\nStage IV\n \nDocumentation and Certification\n\nThe cleaning and disinfection service is documented with a service report with photos and a certificate for a record of due diligence. Documentation supports a site risk reduction program for control of Legionella in cooling water systems.\n\nSEASONAL START UP/SHUTDOWN\n\nThe vendor will do a full check and start-up of all cooling towers and fluid coolers ensuring full operability. \n\nClean debris from the platform and surrounding area.\n\nClean water sump and check condition.\n\nCheck make-up valve operation and adjust accordingly.\n\nCheck and clean bleed-off line and overflow.\n\nClean tower strainers.\n\nCheck the condition of tower spray nozzles and eliminators.\n\nCheck sump heaters and thermostats for calibration and operation.\n\nCheck and adjust fan belts, as necessary.\n\nCheck for leaks.\n\nLubricate fan and motor bearings per manufacturer s recommendations.\n\nCheck the amperage on motors.\n\nInspect electrical connections, contractors, relays, and operating/safety controls.\n \nPARTS REPLACEMENT\n\nAll parts needed to replace failed components of the equipment will be provided by the vendor/contractor. This includes materials or components, such as refrigerant, oil, and other materials the Contractor will provide to perform maintenance and repairs as scheduled under monthly maintenance and seasonal start up.\n\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\nWRITTEN REPORTS\n\nProvided to customer representative following each regular inspection or emergency call. \n\nRequirements for Adjustable or Variable Frequency Drives\n\nANNUAL MAINTENANCE\n\nOnce a year a thorough preventative maintenance schedule will be performed including the following: \n\nBase year   initial base line reading of all VFDs will be provided in written report and subsequent yearly reports will be provided.\n\nRemove all debris, dust, or residue material from the drive enclosure.\n\nClean printed circuit boards with an approved cleaner or small brush.\n\nInspect for any lose plugs or ribbon cables.\n\nInspect for any damaged or missing items.\n\nLook for any overheated or charred components.\n\nLook for discolored components, smudges, or smoke residue.\n\nTighten all connections.\n\nInspect cooling fans for proper operation and change filters quarterly.\n\nCheck the continuity of all control circuit fuses.\n\nPerform diode test of the diode bridges.\n\nPerform continuity check of Debus and bus caps.\n\nPerform diode test of transistors.\n\nCheck and record AC line voltage.\n\nCheck and record motor output lead voltage for balanced supply.\n\nCheck and record Debus voltage.\n\nCompare data with previous tests to expose degradation of components.\n\nPART REPLACEMENT\n\nAll parts needed to replace failed components of the equipment will be provided by the contractor. This includes all materials or components, such as refrigerant, oil, and other materials the Contractor will provide to perform maintenance and repairs as scheduled under annual maintenance.\n\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\n5.5. Task 5: Part 5   Rotary Chillers and Auxiliary Equipment (Process System)\n \nQTY\nDESCRIPTION\nMODEL\nMFG\nTYPE\n\n2\nCHILLERS 1,2\nRTWD250F\nTRANE\nDUAL COMPRESSOR\n134A\n2\nCHILLED WATER PUMPS\nEJMM2531T\nBALDOR\n25HP\n\n2\nCONDENSER PUMPS\nEJMM1531T\nBALDOR\n15HP\n\n4\nPUMP VFD S\n1,2,3,4\nTR200\nTRANE\n\n\n2\nDRY-COOLER CONDENSERS\nREPCM-ACC\nKRAMER\n8 FANS EACH\n\n1\nTRANE TRACER AUTOMATION SYSTEM\nMISC.\nPROCESS CHILLER\n\n\n\n5.5.1. Requirements for Rotary Chillers:\n\nANNUAL MAINTENANCE\n\nOnce a year, thorough preventative maintenance will be performed, including the following\n\nFurnish oil filters and gaskets as required.\n\nPressure test as required using system pressure.\n\nRepair any leaks. Provide refrigerant leak report to owners as required by EPA guidelines.\n\nDetailed inspection of purge system and thorough cleaning of purge compressor, purge oil separator, purge drum. Detailed inspection of purge system to include control circuit diagnostics, purge tank checkout and water removal, replace filter drier cores and clean the air-cooled condenser, if applicable.\n\nCheck the condition of contacts for wear, pitting, etc.\n\nCheck and calibrate safety controls, including all transmitters, flow meters, and all other monitoring devices.\n\nMeg compressor motor and oil pump. Check main starters and perform recommended testing (this includes all the chillers).\n\nCheck main starters and tighten all starter terminals and check contacts for wear.\n\nCheck overloads. \n\nTighten motor terminals and control panel terminals.\n\nClean oil strainer, replace filter and gasket where required. Tighten oil heater leads.\n\nCheck operation of vane position. Take oil sample and have analyzed for acid, moisture, and wear metal content.\n\nChange oil when so indicated by oil analysis unless done on annual schedule.\n\nProvide yearly recommended maintenance on refrigerant monitor along with calibration test, if applicable.\n\nReport any noted deficiencies. \n\nMONTHLY MAINTENANCE\n\nMonthly inspections to be made during the operating season, to include the following: \n\nAdjust operating and safety controls. Record settings.\n\nComplete operating log of temperatures, pressures, and voltages.\n\nChange oil in the purge vacuum pumps when required.\n\nCheck operation of purge system.\n\nCheck operation of control circuit.\n\nCheck operating of lubricant system including oil pump and oil pressure regulator.\n\nCheck operation of motor and starter.\n\nCheck customer log with operator, discuss operation of the machine generally. \n\nReport to operator any uncorrected deficiencies noted.\n\nMake operating log of temperatures, pressures, voltages, amperages, etc.\n\nCheck and adjust operating and safety controls.\n\nCheck operation of oil reservoir sump heater.\n\nCheck oil level and add as required.\n\nCheck operation of control circuit.\n\nheck operating log with operator, discuss operation of the machine generally.\n\nCheck operation of motor and starter. \n\nSEASONAL START UP\n\nThe contractor will advise regarding the start of the month. \n\nTest motor (Meg).\n\nStart machine, check controls, and calibrate.\n\nComplete operating log and record settings monthly.\n\nCheck refrigerant and oil levels.\n\nCheck purge operation.\n\nCheck starter operation, voltage, and current.\n\nSet up operating log with operator, instruct, and advise troubleshooting techniques. \n \nANALYSIS SERVICES\n\nVarious diagnostic tests are to be performed depending on equipment duty and type. Reports with interpretation and recommendations are to be included. \n\nOil sample and analysis for wear metals, acid content, and moisture. Sample to be taken two (2) times per year.\n\nRefrigerant analysis for acid and moisture content (as required). \n\nANNUAL OPERATOR TRAINING\n\nTraining of operators or building engineers on the equipment covered, if required. \n\nEight (8) hours of training per year for every boiler plant employee, up to 16 employees.\n\nAny unutilized training costs will be reimbursed. \n\nPARTS REPLACEMENT: All parts needed to replace failed components on non-covered equipment will be offered at a discount percentage (30%). This does not include materials or components, such as refrigerant, oil, and other materials the contractor will provide to perform maintenance and repairs as emergency or scheduled under annual maintenance, monthly maintenance, seasonal start up and analysis services.\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\nWRITTEN REPORTS\n\nProvided to customer representative following each regular inspection or emergency call. \n\n5.5.2. Requirements for Adjustable or Variable Frequency Drives\n\nANNUAL MAINTENANCE\n\nOnce a year a thorough preventative maintenance schedule will be performed including the following: \n\nBase year   initial base line reading of all VFDs will be provided in written report and subsequent yearly reports will be provided.\n\nRemove all debris, dust, or residue material from the drive enclosure.\n\nClean printed circuit boards with an approved cleaner or small brush.\n\nInspect for any lose plugs or ribbon cables.\n\nInspect for any damaged or missing items.\n\nLook for any overheated or charred components.\n\nLook for discolored components, smudges, or smoke residue.\n\nTighten all connections.\n\nInspect cooling fans for proper operation and change filters quarterly.\n\nCheck the continuity of all control circuit fuses.\n\nPerform diode test of the diode bridges.\n\nPerform continuity check of Debus and bus caps.\n\nPerform diode test of transistors.\n\nCheck and record AC line voltage.\n\nCheck and record motor output lead voltage for balanced supply.\n\nCheck and record Debus voltage.\n\nCompare data with previous tests to expose degradation of components.\n\nPART REPLACEMENT\n\nAll parts needed to replace failed components of the equipment will be provided by the contractor. This includes all materials or components, such as refrigerant, oil, and other materials the Contractor will provide to perform maintenance and repairs as scheduled under annual maintenance.\n\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\nDeliverables\n\nThe contractor will provide the following:\n\nMonthly preventive maintenance/ repair reports on all chiller plant equipment.\nYearly refrigerant leak test reports.\nYearly chiller vibration reports.\nYearly oil test reports.\n\nCopies of all testing results along with certifications will be submitted to the COR. \n\nPerformance Monitoring\n\nThe COR will ensure maintenance and repairs are completed in accordance with the QASP submitted. \n\nCheck   In Requirements\n\nThe Contractor Service Personnel and/or representative must report to the appropriate department Supervisor or designated point of contact (POC) to sign in with department staff before work begins. Additionally, one must submit any mobile media devices that would be used on the system for a virus scan. Upon completion of work, the Contractor Service Personnel and/or representative must report to the appropriate department Supervisor to brief that Supervisor orÂ related department staff point of contact (POC) if Supervisor is unavailable concerning completion of service, and then to sign out. At the end of each briefing, Contractor Service Personnel and/or representative will and must sign out.\n\nSecurity Requirements\n\nThe C&A requirements do not apply, and a Security Accreditation Package is not required.\n\n9.1. Dedicated personnel will be assigned solely to observe, interact, assist, and assure protection of VA sensitive information. \n\n9.2. Contractor employees providing services at VA facilities may undergo a security clearance in the form of a basic background investigation.Â \n\nGeneral Security\n\nContractors, contractor personnel, subcontractors, and subcontractor personnel shall be subject to the same Federal laws, regulations, standards, and VA Directives and Handbooks as VA and VA personnel regarding information and information system security.\n\nVA Information Custodial Language\n\n10.1. Information made available to the contractor or subcontractor by VA for the performance or administration of this contract or information developed by the contractor/subcontractor in performance or administration of the contract shall be used only for those purposes and shall not be used in any other way without the prior written agreement of the VA. This clause expressly limits the contractor/subcontractor's rights to use data as described in Rights in Data - General, FAR 52.227-14(d) (1).\n\n10.2. The contractor/subcontractor must store, transport, or transmit VA sensitive information in an encrypted form, using VA-approved encryption tools that are, at a minimum, FIPS 140-2 validated.\n\nGovernment-Furnished Equipment (GFE)/Government-Furnished Information (GFI)\n\nThere will be no government furnished equipment provided for the purposes of this contract.\n\nOther Pertinent Information or Special Considerations\n\nAny additional testing required outside this contract will require the contractor to submit a quote to COR and receive an approved PO before beginning work.\n\nIdentification of Possible Follow-on Work\n\nN/A\n\nIdentification of Potential Conflicts of Interest (COI)\n\nN/A\n\nIdentification of Non-Disclosure Requirements \n\nNot required\n\nInspection and Acceptance Criteria\n\nThe Contractor will be responsible for meeting timelines listed in this SOW. The COR shall make the final determination for satisfactory acceptance of work performed.\n\nRisk Control\n\nWork performed within the medical center may present health risks including exposure to illness and infection control. Contractor will take action to recognize and follow warning information throughout the facility. \n\nPlace of Performance\n\nLouis Stokes VA Medical Center\n10701 East Blvd.\nCleveland, Ohio 44106 \n\nPeriod of Performance\n\nBase Year: Nov 1, 2025   Oct 31, 2026\nOption Year 1:  Nov 1, 2026   Oct 31, 2027\nOption Year 2:  Nov 1, 2027   Oct 31, 2028\nOption year 3:  Nov 1, 2028   Oct 31, 2029\nOption Year 4:  Nov 1, 2029   Oct 31, 2030\n\nStandard Work Hour\n\nThe Contractor shall perform all services required under this contract during the following standard work hours, except as otherwise authorized in writing by the Contracting Officer:\n\nStandard work hours are Monday through Friday, 8:00 AM to 4:30 PM Eastern Standard Time (EST). The Contractor shall ensure that all necessary personnel are available during these hours to perform the required services effectively. Any requests for deviations from these hours must be approved in advance by the COR. Any services that may cause additional charges or payments to be incurred must be scheduled in advance and approved by the Contracting Officer.\n\nPre-approved Overtime\n\nFor planned, non-emergent overtime work, the Contractor must seek pre-approval in writing from the COR and Contracting Officer. Rates and terms for pre-approved overtime will be detailed in the contract modification or separate PO.\n\nEmergency Work Authorization\n\nIn the event of an emergency that requires immediate attention beyond standard work hours, the Contractor shall respond as quickly as possible to address the issue. The Contractor must obtain verbal authorization from the Contracting Officer or COR before beginning any work.\n\nFederal Holidays\n\nThe following federal holidays are observed by the federal government. On these days, the Contractor is not required to perform services unless otherwise specified in the contract or approved in advance by the Contracting Officer.\n\nNew Year's Day   January 1\nMartin Luther King Jr. Day   Third Monday in January\nPresidents' Day   Third Monday in February\nMemorial Day   Last Monday in May\nJuneteenth   June 19\nIndependence Day   July 4\nLabor Day   First Monday in September\nColumbus Day   Second Monday in October\nVeterans Day   November 11\nThanksgiving Day   Fourth Thursday in November\nChristmas Day   December 25\n\nIn addition to the above federal holidays, the President of the United States can decree new holidays. The Contractor shall observe any such additional holidays as declared.\n\nChanges to the Scope of the Contract\n\nAny changes to this SOW shall be authorized and approved only through written correspondence from the CO. A copy of each change will be kept in a project folder along with all other products of the project. Costs incurred by the contractor through the actions of parties other than the CO shall be borne by the contractor.\n\nThe Government reserves the right to add or remove any additional HVAC systems to the contract if necessary. Furthermore, the Government reserves the right to add, increase, or decrease chiller plant chillers, cooling towers, pumps and any auxiliary equipment to allow for fluctuations of client demand that are otherwise unknown at time of solicitation. The total contract value may increase up to 20% of the base award.","text":"Sources Sought Notice\n\nPage 4 of 4\n\n*= Required Field\nSources Sought Notice\n\nPage 1 of 4\nDepartment of Veterans Affairs\nSources Sought Notice Chiller Plant Maintenance Louis Stokes Cleveland VA Medical Center\n\nThis is a Sources Sought notice and not a request for quotes. This request is solely for the purpose of conducting market research to enhance VHA s understanding of the market s offered products, services and capabilities. The Government will not pay any costs for responses submitted in response to this Sources Sought.\nThe Department of Veterans Affairs (VA), VA Healthcare System, Network Contracting Office (NCO) 10, on behalf of Louis Stokes Cleveland VA Medical Center in Cleveland, Ohio, is conducting market research through this sources sought notice to seek sources that can provide Chiller Plant Maintenance and Services for the Louis Stokes Cleveland VA Medical Center.\n\nThe NAICS Code for this acquisition is 811310, size standard of $12,500,000. The product service code is J041. The contracting office is contemplating award of a Firm-Fixed-Price contract for this service.\n\nThis Sources Sought notice provides an opportunity for respondents to submit their notice of ability, and their available services in response to the requirement described below. Vendors are being invited to submit information relative to their potential of fulfilling the requirement below, in the form of a capability response that addresses the specific requirement identified in this Sources Sought. Pursuant to FAR Part 10, Market Research, the purpose of this notice is to determine if sources capable of satisfying the agency's requirements exists and to determine the commercial practices of company's engaged in providing the needed service. Pursuant to FAR Part 6 and FAR Part 19, competition and set-aside decisions may be based on the results of this market research. This notice in no way obligates the Government to any further action.\n\nThis is a \"REQUEST FOR INFORMATION\" only. Requests for a solicitation will not receive a response.\n\nDESCRIPTION\nThe Louis Stokes VA Medical Center located at 10701 East Blvd, Cleveland, Ohio 44106 is seeking a qualified contractor to provide all labor, materials, equipment, transportation, and supervision necessary to provide full-service, on-site Chiller Plant Maintenance to maintain and service all chillers, pumps, cooling towers, VFDs, and building automation controls necessary to cool and de-humidify the Medical Center for the health and safety of our patients, staff, medical equipment and visitors.\n\nGENERAL REQUIREMENTS\nPlease provide the requested information with any responses:\n\n1. Company Name and POC information.\n2. SAM.gov UEI number.\n3. GSA contract number if these services are offered on Federal Supply Schedule.\n4. Socioeconomic category (SDVOSB, VOSB, WOSB, 8a, Small Business or Large Business). If this contract is set-aside, it will be subject to the Limitations on Subcontracting rules per FAR 52.219-14, 13 CFR 125.6 and VAAR 852.219-75.\n5. Please provide a capability statement that addresses the organization s qualifications and ability to perform as a contractor for the work described below.\n6. Statement ensuring any licenses, insurances, training, certifications, or special accommodations necessary to perform this task will be met. If there are specific requirements, please provide rationale.\n7. Any questions, comments, or concerns, that may otherwise assist us.\n\nRESPONSE COMMITMENT\nPlease send all inquiries to: chad.kemper@va.gov. Phone calls will not be accepted.\n\nEligibility in participating in a future acquisition does not depend upon a response to this notice.\n?.## STATEMENT OF WORK (SOW)\n\nContract Title\n\nChiller Plant Maintenance\n\nBackground\n\nThe Louis Stokes VA Medical Center located at 10701 East Blvd, Cleveland, Ohio 44106 is seeking a qualified contractor to provide all labor, materials, equipment, transportation, and supervision necessary to provide full-service, on-site Chiller Plant Maintenance to maintain and service all chillers, pumps, cooling towers, VFDs, and building automation controls necessary to cool and de-humidify the Medical Center for the health and safety of our patients, staff, medical equipment and visitors.\n\nScope\n\nThe vendor shall supply all labor, materials, equipment, clean up, transportation, and supervision necessary to perform all full-service, on-site maintenance, repairs, and replacement as scheduled and needed to the chiller plant chillers, cooling towers, pumps and any auxiliary equipment located at Louis Stokes Cleveland VA Medical Center to maintain the equipment in full operational status. This will include all equipment listed in Parts One, Two, Three, Four and Five. Vendor will have documented certified technicians and the ability to provide repair and replacement parts.\n\nThe Louis Stokes Cleveland VA Medical Center is expecting to add an additional/new chiller during Fiscal Year 2026. The new Chiller will be added to the scope of the contract.\n\nSpecific Tasks\n\nSee equipment list and maintenance description below:\n\n5.1. Task 1: Part One - Centrifugal Chillers\n\nNUMBER\nMFG\nMODEL\n\nTONS/ OUTPUT\n\nCH-I\nTRANE\nCVHF128NA\n1,200\n4160V\nCH-2\nTRANE\nCVHF128NA\n1,200\n4160V\nCH-3\nTRANE\nCVHF128NA\n1 ,200\n4160V\nCH-4\nTRANE\nCVHF1280\n1,200\n480V\nCH-5\nTRANE\nCVHF13DFA\n1,200\n480V\n\n5.1.1. Requirements for Centrifugal Chillers and Rotary Chillers:\n\nANNUAL Maintenance\n\nOnce a year, thorough preventative maintenance will be performed, including the following:\n\nFurnish oil filters and gaskets as required.\n\nPressure test as required using system pressure.\n\nRepair any leaks. Provide refrigerant leak reports to owners as required by EPA guidelines.\n\nDetailed inspection of purge system and thorough cleaning of purge compressor, purge oil separator, purge drum. Detailed inspection of purge system to include control circuit diagnostics, purge tank checkout and water removal, replace filter drier cores and clean the air-cooled condenser, if applicable.\n\nCheck the condition of contacts for wear, pitting, etc.\n\nCheck and calibrate safety controls, including all transmitters, flow meters, and all other monitoring devices.\n\nMeg compressor motor and oil pump. Check main starters and perform recommended testing (this includes all the chillers).\n\nCheck the main starters, tighten all starter terminals, and check contacts for wear.\n\nCheck overloads.\n\nTighten motor terminals and control panel terminals.\n\nClean oil strainer, replace filter and gasket where required. Tighten oil heater leads.\n\nCheck operation of vane position. Take oil sample and have analyzed for acid, moisture, and wear metal content.\n\nChange oil when so indicated by oil analysis unless done on annual schedule.\n\nProvide yearly recommended maintenance on refrigerant monitor along with calibration test, if applicable.\n\nReport any noted deficiencies.\n\nMonthly Maintenance:\n\nMonthly inspections to be made during the operating season, to include the following:\n\nAdjust operating and safety controls. Record settings.\n\nComplete operating log of temperatures, pressures, and voltages.\n\nChange oil in purge vacuum pumps when required.\n\nCheck operation of purge system.\n\nCheck operation of control circuit.\n\nCheck operating of lubricant system including oil pump and oil pressure regulator.\n\nCheck operation of motor and starter.\n\nCheck customer log with the operator, discuss operation of the machine generally.\n\nReport to operator any uncorrected deficiencies noted.\n\nMake operating log of temperatures, pressures, voltages, amperages, etc.\n\nCheck and adjust operating and safety controls.\n\nCheck operation of oil reservoir sump heater.\n\nCheck oil level and add as required.\n\nCheck operation of control circuit.\n\nCheck operating log with operator, discuss operation of the machine generally.\n\nCheck operation of motor and starter.\n\nSeasonal Start Up\n\nThe contractor will advise regarding the start of the month.\n\n1. Test motor (Meg).\n\n2. Start the machine, check controls, and calibrate.\n\n3. Complete operating log and record settings monthly.\n\n4. Check refrigerant and oil levels.\n\n5. Check purge operation.\n\n6. Check starter operation, voltage, and current.\n\nSet up operating log with operator, instruct, and advise troubleshooting techniques.\n\nAnalysis Services\n\nVarious diagnostic tests are to be performed depending on equipment duty and type. Reports with interpretation and recommendations are to be included.\n\n1. Oil sample and analysis for wear metals, acid content, and moisture. Sample to be taken two (2) times per year.\n\n2. Refrigerant analysis for acid and moisture content (as required).\n\nAnnual Operator Training\n\nTraining of operators or building engineers on the equipment covered, if required.\n\n1. Eight (8) hours of training per year for every boiler plant employee, up to 16 employees.\n\n2. Any un-utilized training costs will be reimbursed.\n\nParts Replacement\n\nAll parts needed to replace failed components on non-covered equipment will be offered at a discount percentage (30%). This does not include materials or components, such as refrigerant, oil, and other materials the contractor will provide to perform maintenance and repairs as emergencies or scheduled under annual maintenance, monthly maintenance, seasonal start up and analysis services.\n\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\nWritten Reports:\n\nProvided to customer representative following each regular inspection or emergency call.\n\n5.2. Task 2: Part Two Trace Automation & Controls\n\n5.2.1. Requirements for Tracer Automation Equipment Main Plant and Process Chiller Plant:\n\nA. Contractor will provide full-service coverage for regular systematic maintenance and parts, materials and labor for repairs, including all software support, defects in materials or manufacture, or due to normal wear and tear.\n\nB. Contractor will provide and install any new operational software and/or graphics with the latest revisions over the course of the contract.\n\nC. Unit maintenance and repair/replacement of PCs, Monitors, UPSs and associated equipment will be the liability of the contractor over the duration of the contract with no additional cost.\n\nD. Scheduled maintenance includes diagnosis of system performance, inspection, cleaning, adjustments, and other procedures as required by specifications according to system use and configuration.\n\nSemi-Annual Preventative Maintenance\n\nMaintenance/repair or replacement if required of the Building Automation Systems. Includes all operated valves, programming panels, BCU s, Tracer Output/Input panels and workstations associated with Energy Center equipment and operations, to include the following:\n\nMaster Station\n\nCheck the operating environment and clean the console. Check and clean the central processing unit and record input voltage.\n\n2. If necessitated by operational difficulties, run system diagnostics. Contractor will provide and install any new operational software and/or graphics with the most current version at no cost over the course of the contract.\n\n3. Clean and maintain BCU modules in both the Penthouse and Ambulatory Care.\n\n4. Check and clean CRTs and Printers.\n\n5. Perform complete system backup.\n\n6. Remote Stations and Field Hardware:\n\nVerify regulated power assembly and battery voltages, adjust as required.\n\nInspect cabinet at earth ground potential.\n\nVerify proper system electrical ground isolation.\n\nInspect interconnecting cables and electrical connections.\n\nVia terminal exercise-controlled devices with manual command functions and verify proper response of connected field hardware.\n\nCheck for alarms and overrides. Note specific alarm and override conditions for review with the owner personnel.\n\nClean external surfaces of the panel enclosure and associated field equipment units.\n\nReview system performance with Medical Centers designated contact.\n\nDiscuss specific parameter changes implemented as required.\n\nInspect interior surfaces and components of the panel enclosure and associated field equipment.\n\nEnsure all mounted devices add plug in components are securely in place.\n\nEvaluate binary and analog points for proper operation and reporting Perform a general performance review of all points.\n\nCheck individual critical points. Determine new or revised calibration coefficients as required.\n\nRecord any parameter values which are different than those shown on program listings.\n\nANNUAL OPERATOR TRAINING\n\nThe contractor will provide up to eight (8) hours of Tracer Summit on-site customer training, if requested.\n\nWRITTEN REPORTS\n\nProvided written reports to COR following each regular inspection or emergency call.\n\n5.3. Task 3: Part Three Chill Water/Tower Water Pumps, & Drives\nNUMBER\nMFG\nMODEL\nSERVICE\n\nCWP-I\nWEINMAN\n444TT\nCHILLED WATER\n2400GPM\n150HP\nCWP-2\nWEINMAN\n444TT\nCHILLED WATER\n2400GPM\n150HP\nCWP-3\nWEINMAN\n444TT\nCHILLED WATER\n2400GPM\n150HP\nCWP-4\nWEINMAN\n444TT\nCHILLED WATER\n2400GPM\n150HP\nCWP-5\nPACO\n444TT\nCHILLED WATER\n2400GPM\n150HP\nCWP-6\nPACO\n444TT\nCHILLED WATER\n2400GPM\n150HP\nVFD CWP-1\nDANFOSS/ GRAHAM\nVLT6000H190\nCHILLED WATER\n\n480V\nVFD CWP-2\nDANFOSS/ GRAHAM\nVLT6000H190\nCHILLED WATER\n\n480V\nVFD CWP-3\nDANFOSS/ GRAHAM\nVLT6000H190\nCHILLED WATER\n\n480V\nVFD CWP-4\nHONEYWELL\nSMART VFD\nHVFDSD3C1500G100\nCHILLED WATER\n\n480V\nVFD CWP-5\nEATON\nCFX9000\nCHILLED\nWATER\n\n480V\nVFD CWP-6\nEATON\nSVX9000\nCHILLED\nWATER\n\n480V\nTWP-I\nWEINMAN\n12L2\nTOWER\nWATER\n3600GPM\n100HP\nTWP-2\nWEINMAN\n12102\nTOWER\nWATER\n3600GPM\n100HP\nTWP-3\nWEINMAN\n12L2\nTOWER\nWATER\n3600GPM\n100HP\nTWP-4\nWEINMAN\n12L2\nTOWER\nWATER\n3600GPM\n100HP\nTWP-5\nPACO\nKP8012-56\nTOWER\nWATER\n3600GPM\n100HP\nTWP-6\nPACO\n8012\nTOWER\nWATER\n3600GPM\n100HP\nVFD-TWP-1\nDANFOSS/ GRAHAM\nMCD3075\nTOWER\nWATER\n\n480V\nVFD-TWP-2\nDANFOSS/ GRAHAM\nMCD3075\nTOWER\nWATER\n\n480V\nVFD-TWP-3\nDANFOSS/ GRAHAM\nMCD3075\nTOWER\nWATER\n\n480V\nVFD-TWP-4\nEATON\nSVX9000\nTOWER\nWATER\n\n480V\nVFD-TWP-5\nEATON\nCFX9000\nTOWER\nPUMP\n\n480V\nVFD-TWP-6\nEATON\nSVX9000\nTOWER\nPUMP\n\n480V\n\n5.3.1. Requirements for all Chill-Water, Tower/Condenser Water Pumps:\n\nMonthly Maintenance\n\nMonthly inspections to be made during the operating season, to include the following:\n\n1. Lubricate pump bearings per manufacturer s recommendations.\n\n2. Lubricate motor bearings per manufacturer s recommendations.\n\n3. Check the suction and discharge pressures.\n\n4. Check packing or mechanical seal and adjust as necessary.\n\n5. Check motor voltage and amperage.\n\nSEASONAL START UP\n\n1. Clean pump strainers.\n\n2. Lubricate pump bearings per manufacturer s recommendations.\n\n3. Lubricate motor bearings per manufacturer s recommendations.\n\n4. Tighten all nuts and bolts. Check motor mounts and vibration pads.\n\n5. Visually check pump alignment and coupling.\n\n6. Check motor operating conditions.\n\n7. Inspect electrical connections and contractors.\n\n8. check mechanical seals or pump packing.\n\n9. Operate pumps and check efficiency.\n\nPARTS REPLACEMENT\n\nAll parts or failed components of the equipment needed to be replaced will be provided by the vendor/contractor. This includes all materials or components, such as refrigerant, oil, and other materials the Contractor will provide to perform maintenance and repairs as scheduled under monthly maintenance and seasonal start up.\n\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\nWRITTEN REPORTS\n\nProvided to customer representative following each regular inspection or emergency call.\n\n5.3.2. Requirements for Adjustable or Variable Frequency Drives\n\nANNUAL MAINTENANCE: Once a year a thorough preventative maintenance schedule will be performed including the following:\n\nBase year initial base line reading of all VFDs will be provided in written report and subsequent yearly reports will be provided.\n\nRemove all debris, dust, or residue material from the drive enclosure.\n\nClean printed circuit boards with an approved cleaner or small brush.\n\nInspect for any lose plugs or ribbon cables.\n\nInspect for any damaged or missing items.\n\nLook for any overheated or charred components.\n\nLook for discolored components, smudges, or smoke residue.\n\nTighten all connections.\n\nInspect cooling fans for proper operation and change filters quarterly.\n\nCheck the continuity of all control circuit fuses.\n\nPerform diode test of the diode bridges.\n\nPerform continuity check of Debus and bus caps.\n\nPerform diode test of transistors.\n\nCheck and record AC line voltage.\n\nCheck and record motor output lead voltage for balanced supply.\n\nCheck and record Debus voltage.\n\nCompare data with previous tests to expose degradation of components.\n\nPART REPLACEMENT\n\nAll parts needed to replace failed components of the equipment will be provided by the contractor. This includes all materials or components, such as refrigerant, oil, and other materials the Contractor will provide to perform maintenance and repairs as scheduled under annual maintenance.\n\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\n5.4. Task 4: Part Four Cooling Towers, Cooling Tower Fan Drives, Semi-Annual Tower Cleaning, & Disinfection\n\nNUMBER\nMFG\nMODEL\nTONS\nMOTOR\n\nCT-I\nEVAPCO\nREP 224-018\n1200TONS\n2CELLS\n\nCT-2\nEVAPCO\nREP 224-018\n1200TONS\n2CELLS\n\nCT-3\nEVAPCO\nREP 224-018\n1200TONS\n2CELLS\n\nCT-4\nEVAPCO\nREP224-118\n1200TONS\n2CELLS\n\nCT-5\nEVAPCO\nAT224-118\n1200TONS\n2CELLS\n\nVFD-CT-I\nHONEYWELL SMART VFD\nHVFOSD306005100\nCOOLING TOWER\nFANS\n30\n60HZ\nVFD-CT-2\nDANFOSS/ GRAHAM\nVLT6000\nCOOLING TOWER\nFANS\n30\n60HZ\nVFD-CT-3\nDANFOSS/ GRAHAM\nVLT6000\nCOOLING\nTOWER\nFANS\n2 @ 30EA\n60HZ\nVFD-CT-4B\nEATON\nCFX9000\nCOOLING\nTOWER\nFAN\n1\n\n30HZ\nVFD-CT4A\nHONEYWELL\nNXS0300A1001\nCOOLING TOWER FAN\n1\n30HZ\nVFD-CT-5\nEATON\nSVX9000\nFANS\n2\n60HZ\n\n5.4.1. Requirements for Cooling Towers/Fluid Coolers\n\nMONTHLY MAINTENANCE\n\nMonthly inspections are to be made during the operating season, to include the following:\n\nInspect the fan, motor, and belt. Check the oil level and add oil as needed.\n\nCheck the intake strainer on cooling towers.\n\nCheck operating conditions. Adjust as required.\n\nCLEANING & DISINFECTION PROCESS\n\nTo be completed in early Spring (March/April) and late Fall (October/November) dependent on weather conditions and scheduled through the COR.\n\nThe following stages highlight the general approach for cleaning and disinfection of cooling water systems. Certain modifications may be required depending on system access, design, operation or the like. All stages in the clean and disinfection process shall require assistance from the Customer such as the operation engineer who is familiar with the system. All supplies and PPE will be contractor supplied. Proper LOTO will be utilized as needed.\n\nStage I\n\nPre-Clean Disinfection for the destruction of biofilms and pathogens\n\nAll cooling tower fans must be shut OFF and proper LOTO procedures in place prior to start of process, and all recirculation pumps must be ON.\n\nThe system is disinfected using an oxidizing biocide such as chlorine or an equivalent chemistry.\n\nA bio dispersant may also be added to help remove organic deposits and\nenhance disinfection.\n\nStage II\n\nMechanical Cleaning for surface sanitation and removal of deposits\nEach system cell and/or sump is isolated and drained for mechanical cleaning.\n\nEach system cell is pressure washed from top to bottom, internal and external, as is reasonably accessible to remove deposits.\n\nExceptional care is taken to remove deposits without damaging the fill pack.\n\nDeposits, including the sump if included in the scope, are removed for disposal. The Customer shall assist with disposal in the appropriate dumpsters or equivalents.\n\nStage III\n\nPost-Clean Disinfection for the destruction of dislodged biofilms and pathogens.\n\nAll cooling tower fans must be shut OFF, and all recirculation pumps must be ON.\n\nThe system is disinfected using an oxidizing biocide such as chlorine or equivalent chemistry.\n\nThe full water treatment program must be immediately resumed following the disinfection step to re-passivate system metallurgy.\n\nStage IV\n\nDocumentation and Certification\n\nThe cleaning and disinfection service is documented with a service report with photos and a certificate for a record of due diligence. Documentation supports a site risk reduction program for control of Legionella in cooling water systems.\n\nSEASONAL START UP/SHUTDOWN\n\nThe vendor will do a full check and start-up of all cooling towers and fluid coolers ensuring full operability.\n\nClean debris from the platform and surrounding area.\n\nClean water sump and check condition.\n\nCheck make-up valve operation and adjust accordingly.\n\nCheck and clean bleed-off line and overflow.\n\nClean tower strainers.\n\nCheck the condition of tower spray nozzles and eliminators.\n\nCheck sump heaters and thermostats for calibration and operation.\n\nCheck and adjust fan belts, as necessary.\n\nCheck for leaks.\n\nLubricate fan and motor bearings per manufacturer s recommendations.\n\nCheck the amperage on motors.\n\nInspect electrical connections, contractors, relays, and operating/safety controls.\n\nPARTS REPLACEMENT\n\nAll parts needed to replace failed components of the equipment will be provided by the vendor/contractor. This includes materials or components, such as refrigerant, oil, and other materials the Contractor will provide to perform maintenance and repairs as scheduled under monthly maintenance and seasonal start up.\n\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\nWRITTEN REPORTS\n\nProvided to customer representative following each regular inspection or emergency call.\n\nRequirements for Adjustable or Variable Frequency Drives\n\nANNUAL MAINTENANCE\n\nOnce a year a thorough preventative maintenance schedule will be performed including the following:\n\nBase year initial base line reading of all VFDs will be provided in written report and subsequent yearly reports will be provided.\n\nRemove all debris, dust, or residue material from the drive enclosure.\n\nClean printed circuit boards with an approved cleaner or small brush.\n\nInspect for any lose plugs or ribbon cables.\n\nInspect for any damaged or missing items.\n\nLook for any overheated or charred components.\n\nLook for discolored components, smudges, or smoke residue.\n\nTighten all connections.\n\nInspect cooling fans for proper operation and change filters quarterly.\n\nCheck the continuity of all control circuit fuses.\n\nPerform diode test of the diode bridges.\n\nPerform continuity check of Debus and bus caps.\n\nPerform diode test of transistors.\n\nCheck and record AC line voltage.\n\nCheck and record motor output lead voltage for balanced supply.\n\nCheck and record Debus voltage.\n\nCompare data with previous tests to expose degradation of components.\n\nPART REPLACEMENT\n\nAll parts needed to replace failed components of the equipment will be provided by the contractor. This includes all materials or components, such as refrigerant, oil, and other materials the Contractor will provide to perform maintenance and repairs as scheduled under annual maintenance.\n\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\n5.5. Task 5: Part 5 Rotary Chillers and Auxiliary Equipment (Process System)\n\nQTY\nDESCRIPTION\nMODEL\nMFG\nTYPE\n\n2\nCHILLERS 1,2\nRTWD250F\nTRANE\nDUAL COMPRESSOR\n134A\n2\nCHILLED WATER PUMPS\nEJMM2531T\nBALDOR\n25HP\n\n2\nCONDENSER PUMPS\nEJMM1531T\nBALDOR\n15HP\n\n4\nPUMP VFD S\n1,2,3,4\nTR200\nTRANE\n\n2\nDRY-COOLER CONDENSERS\nREPCM-ACC\nKRAMER\n8 FANS EACH\n\n1\nTRANE TRACER AUTOMATION SYSTEM\nMISC.\nPROCESS CHILLER\n\n5.5.1. Requirements for Rotary Chillers:\n\nANNUAL MAINTENANCE\n\nOnce a year, thorough preventative maintenance will be performed, including the following\n\nFurnish oil filters and gaskets as required.\n\nPressure test as required using system pressure.\n\nRepair any leaks. Provide refrigerant leak report to owners as required by EPA guidelines.\n\nDetailed inspection of purge system and thorough cleaning of purge compressor, purge oil separator, purge drum. Detailed inspection of purge system to include control circuit diagnostics, purge tank checkout and water removal, replace filter drier cores and clean the air-cooled condenser, if applicable.\n\nCheck the condition of contacts for wear, pitting, etc.\n\nCheck and calibrate safety controls, including all transmitters, flow meters, and all other monitoring devices.\n\nMeg compressor motor and oil pump. Check main starters and perform recommended testing (this includes all the chillers).\n\nCheck main starters and tighten all starter terminals and check contacts for wear.\n\nCheck overloads.\n\nTighten motor terminals and control panel terminals.\n\nClean oil strainer, replace filter and gasket where required. Tighten oil heater leads.\n\nCheck operation of vane position. Take oil sample and have analyzed for acid, moisture, and wear metal content.\n\nChange oil when so indicated by oil analysis unless done on annual schedule.\n\nProvide yearly recommended maintenance on refrigerant monitor along with calibration test, if applicable.\n\nReport any noted deficiencies.\n\nMONTHLY MAINTENANCE\n\nMonthly inspections to be made during the operating season, to include the following:\n\nAdjust operating and safety controls. Record settings.\n\nComplete operating log of temperatures, pressures, and voltages.\n\nChange oil in the purge vacuum pumps when required.\n\nCheck operation of purge system.\n\nCheck operation of control circuit.\n\nCheck operating of lubricant system including oil pump and oil pressure regulator.\n\nCheck operation of motor and starter.\n\nCheck customer log with operator, discuss operation of the machine generally.\n\nReport to operator any uncorrected deficiencies noted.\n\nMake operating log of temperatures, pressures, voltages, amperages, etc.\n\nCheck and adjust operating and safety controls.\n\nCheck operation of oil reservoir sump heater.\n\nCheck oil level and add as required.\n\nCheck operation of control circuit.\n\nheck operating log with operator, discuss operation of the machine generally.\n\nCheck operation of motor and starter.\n\nSEASONAL START UP\n\nThe contractor will advise regarding the start of the month.\n\nTest motor (Meg).\n\nStart machine, check controls, and calibrate.\n\nComplete operating log and record settings monthly.\n\nCheck refrigerant and oil levels.\n\nCheck purge operation.\n\nCheck starter operation, voltage, and current.\n\nSet up operating log with operator, instruct, and advise troubleshooting techniques.\n\nANALYSIS SERVICES\n\nVarious diagnostic tests are to be performed depending on equipment duty and type. Reports with interpretation and recommendations are to be included.\n\nOil sample and analysis for wear metals, acid content, and moisture. Sample to be taken two (2) times per year.\n\nRefrigerant analysis for acid and moisture content (as required).\n\nANNUAL OPERATOR TRAINING\n\nTraining of operators or building engineers on the equipment covered, if required.\n\nEight (8) hours of training per year for every boiler plant employee, up to 16 employees.\n\nAny unutilized training costs will be reimbursed.\n\nPARTS REPLACEMENT: All parts needed to replace failed components on non-covered equipment will be offered at a discount percentage (30%). This does not include materials or components, such as refrigerant, oil, and other materials the contractor will provide to perform maintenance and repairs as emergency or scheduled under annual maintenance, monthly maintenance, seasonal start up and analysis services.\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\nWRITTEN REPORTS\n\nProvided to customer representative following each regular inspection or emergency call.\n\n5.5.2. Requirements for Adjustable or Variable Frequency Drives\n\nANNUAL MAINTENANCE\n\nOnce a year a thorough preventative maintenance schedule will be performed including the following:\n\nBase year initial base line reading of all VFDs will be provided in written report and subsequent yearly reports will be provided.\n\nRemove all debris, dust, or residue material from the drive enclosure.\n\nClean printed circuit boards with an approved cleaner or small brush.\n\nInspect for any lose plugs or ribbon cables.\n\nInspect for any damaged or missing items.\n\nLook for any overheated or charred components.\n\nLook for discolored components, smudges, or smoke residue.\n\nTighten all connections.\n\nInspect cooling fans for proper operation and change filters quarterly.\n\nCheck the continuity of all control circuit fuses.\n\nPerform diode test of the diode bridges.\n\nPerform continuity check of Debus and bus caps.\n\nPerform diode test of transistors.\n\nCheck and record AC line voltage.\n\nCheck and record motor output lead voltage for balanced supply.\n\nCheck and record Debus voltage.\n\nCompare data with previous tests to expose degradation of components.\n\nPART REPLACEMENT\n\nAll parts needed to replace failed components of the equipment will be provided by the contractor. This includes all materials or components, such as refrigerant, oil, and other materials the Contractor will provide to perform maintenance and repairs as scheduled under annual maintenance.\n\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\nDeliverables\n\nThe contractor will provide the following:\n\nMonthly preventive maintenance/ repair reports on all chiller plant equipment.\nYearly refrigerant leak test reports.\nYearly chiller vibration reports.\nYearly oil test reports.\n\nCopies of all testing results along with certifications will be submitted to the COR.\n\nPerformance Monitoring\n\nThe COR will ensure maintenance and repairs are completed in accordance with the QASP submitted.\n\nCheck In Requirements\n\nThe Contractor Service Personnel and/or representative must report to the appropriate department Supervisor or designated point of contact (POC) to sign in with department staff before work begins. Additionally, one must submit any mobile media devices that would be used on the system for a virus scan. Upon completion of work, the Contractor Service Personnel and/or representative must report to the appropriate department Supervisor to brief that Supervisor orÂ related department staff point of contact (POC) if Supervisor is unavailable concerning completion of service, and then to sign out. At the end of each briefing, Contractor Service Personnel and/or representative will and must sign out.\n\nSecurity Requirements\n\nThe C&A requirements do not apply, and a Security Accreditation Package is not required.\n\n9.1. Dedicated personnel will be assigned solely to observe, interact, assist, and assure protection of VA sensitive information.\n\n9.2. Contractor employees providing services at VA facilities may undergo a security clearance in the form of a basic background investigation.Â\n\nGeneral Security\n\nContractors, contractor personnel, subcontractors, and subcontractor personnel shall be subject to the same Federal laws, regulations, standards, and VA Directives and Handbooks as VA and VA personnel regarding information and information system security.\n\nVA Information Custodial Language\n\n10.1. Information made available to the contractor or subcontractor by VA for the performance or administration of this contract or information developed by the contractor/subcontractor in performance or administration of the contract shall be used only for those purposes and shall not be used in any other way without the prior written agreement of the VA. This clause expressly limits the contractor/subcontractor's rights to use data as described in Rights in Data - General, FAR 52.227-14(d) (1).\n\n10.2. The contractor/subcontractor must store, transport, or transmit VA sensitive information in an encrypted form, using VA-approved encryption tools that are, at a minimum, FIPS 140-2 validated.\n\nGovernment-Furnished Equipment (GFE)/Government-Furnished Information (GFI)\n\nThere will be no government furnished equipment provided for the purposes of this contract.\n\nOther Pertinent Information or Special Considerations\n\nAny additional testing required outside this contract will require the contractor to submit a quote to COR and receive an approved PO before beginning work.\n\nIdentification of Possible Follow-on Work\n\nN/A\n\nIdentification of Potential Conflicts of Interest (COI)\n\nN/A\n\nIdentification of Non-Disclosure Requirements\n\nNot required\n\nInspection and Acceptance Criteria\n\nThe Contractor will be responsible for meeting timelines listed in this SOW. The COR shall make the final determination for satisfactory acceptance of work performed.\n\nRisk Control\n\nWork performed within the medical center may present health risks including exposure to illness and infection control. Contractor will take action to recognize and follow warning information throughout the facility.\n\nPlace of Performance\n\nLouis Stokes VA Medical Center\n10701 East Blvd.\nCleveland, Ohio 44106\n\nPeriod of Performance\n\nBase Year: Nov 1, 2025 Oct 31, 2026\nOption Year 1: Nov 1, 2026 Oct 31, 2027\nOption Year 2: Nov 1, 2027 Oct 31, 2028\nOption year 3: Nov 1, 2028 Oct 31, 2029\nOption Year 4: Nov 1, 2029 Oct 31, 2030\n\nStandard Work Hour\n\nThe Contractor shall perform all services required under this contract during the following standard work hours, except as otherwise authorized in writing by the Contracting Officer:\n\nStandard work hours are Monday through Friday, 8:00 AM to 4:30 PM Eastern Standard Time (EST). The Contractor shall ensure that all necessary personnel are available during these hours to perform the required services effectively. Any requests for deviations from these hours must be approved in advance by the COR. Any services that may cause additional charges or payments to be incurred must be scheduled in advance and approved by the Contracting Officer.\n\nPre-approved Overtime\n\nFor planned, non-emergent overtime work, the Contractor must seek pre-approval in writing from the COR and Contracting Officer. Rates and terms for pre-approved overtime will be detailed in the contract modification or separate PO.\n\nEmergency Work Authorization\n\nIn the event of an emergency that requires immediate attention beyond standard work hours, the Contractor shall respond as quickly as possible to address the issue. The Contractor must obtain verbal authorization from the Contracting Officer or COR before beginning any work.\n\nFederal Holidays\n\nThe following federal holidays are observed by the federal government. On these days, the Contractor is not required to perform services unless otherwise specified in the contract or approved in advance by the Contracting Officer.\n\nNew Year's Day January 1\nMartin Luther King Jr. Day Third Monday in January\nPresidents' Day Third Monday in February\nMemorial Day Last Monday in May\nJuneteenth June 19\nIndependence Day July 4\nLabor Day First Monday in September\nColumbus Day Second Monday in October\nVeterans Day November 11\nThanksgiving Day Fourth Thursday in November\nChristmas Day December 25\n\nIn addition to the above federal holidays, the President of the United States can decree new holidays. The Contractor shall observe any such additional holidays as declared.\n\nChanges to the Scope of the Contract\n\nAny changes to this SOW shall be authorized and approved only through written correspondence from the CO. A copy of each change will be kept in a project folder along with all other products of the project. Costs incurred by the contractor through the actions of parties other than the CO shall be borne by the contractor.\n\nThe Government reserves the right to add or remove any additional HVAC systems to the contract if necessary. Furthermore, the Government reserves the right to add, increase, or decrease chiller plant chillers, cooling towers, pumps and any auxiliary equipment to allow for fluctuations of client demand that are otherwise unknown at time of solicitation. The total contract value may increase up to 20% of the base award.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25026Q0018","place_of_performance":{"zip":"44106-1702","city":{"name":"Cleveland"},"state":{"code":"OH","name":"Ohio"},"street":"Department of Veterans Affairs Louis Stokes Cleveland VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"10701 East Blvd"},"product_service_code":"J041"}],"due_at":"2025-09-12T18:00:00Z","due_date":"2025-09-12","closes_at":"2025-09-12T18:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","state_source":null,"state_evidence":null,"site_key":"cleveland-va-medical-center-oh","winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-02T00:27:51.121586Z","principal_notice_id":"1b47eb37f6cd41f99a3ea9641897ba0e","description":{"text":"Sources Sought Notice\n\nPage 4 of 4\n\n*= Required Field\nSources Sought Notice\n\nPage 1 of 4\nDepartment of Veterans Affairs\nSources Sought Notice Chiller Plant Maintenance Louis Stokes Cleveland VA Medical Center\n\nThis is a Sources Sought notice and not a request for quotes. This request is solely for the purpose of conducting market research to enhance VHA s understanding of the market s offered products, services and capabilities. The Government will not pay any costs for responses submitted in response to this Sources Sought.\nThe Department of Veterans Affairs (VA), VA Healthcare System, Network Contracting Office (NCO) 10, on behalf of Louis Stokes Cleveland VA Medical Center in Cleveland, Ohio, is conducting market research through this sources sought notice to seek sources that can provide Chiller Plant Maintenance and Services for the Louis Stokes Cleveland VA Medical Center.\n\nThe NAICS Code for this acquisition is 811310, size standard of $12,500,000. The product service code is J041. The contracting office is contemplating award of a Firm-Fixed-Price contract for this service.\n\nThis Sources Sought notice provides an opportunity for respondents to submit their notice of ability, and their available services in response to the requirement described below. Vendors are being invited to submit information relative to their potential of fulfilling the requirement below, in the form of a capability response that addresses the specific requirement identified in this Sources Sought. Pursuant to FAR Part 10, Market Research, the purpose of this notice is to determine if sources capable of satisfying the agency's requirements exists and to determine the commercial practices of company's engaged in providing the needed service. Pursuant to FAR Part 6 and FAR Part 19, competition and set-aside decisions may be based on the results of this market research. This notice in no way obligates the Government to any further action.\n\nThis is a \"REQUEST FOR INFORMATION\" only. Requests for a solicitation will not receive a response.\n\nDESCRIPTION\nThe Louis Stokes VA Medical Center located at 10701 East Blvd, Cleveland, Ohio 44106 is seeking a qualified contractor to provide all labor, materials, equipment, transportation, and supervision necessary to provide full-service, on-site Chiller Plant Maintenance to maintain and service all chillers, pumps, cooling towers, VFDs, and building automation controls necessary to cool and de-humidify the Medical Center for the health and safety of our patients, staff, medical equipment and visitors.\n\nGENERAL REQUIREMENTS\nPlease provide the requested information with any responses:\n\n1. Company Name and POC information.\n2. SAM.gov UEI number.\n3. GSA contract number if these services are offered on Federal Supply Schedule.\n4. Socioeconomic category (SDVOSB, VOSB, WOSB, 8a, Small Business or Large Business). If this contract is set-aside, it will be subject to the Limitations on Subcontracting rules per FAR 52.219-14, 13 CFR 125.6 and VAAR 852.219-75.\n5. Please provide a capability statement that addresses the organization s qualifications and ability to perform as a contractor for the work described below.\n6. Statement ensuring any licenses, insurances, training, certifications, or special accommodations necessary to perform this task will be met. If there are specific requirements, please provide rationale.\n7. Any questions, comments, or concerns, that may otherwise assist us.\n\nRESPONSE COMMITMENT\nPlease send all inquiries to: chad.kemper@va.gov. Phone calls will not be accepted.\n\nEligibility in participating in a future acquisition does not depend upon a response to this notice.\n?.## STATEMENT OF WORK (SOW)\n\nContract Title\n\nChiller Plant Maintenance\n\nBackground\n\nThe Louis Stokes VA Medical Center located at 10701 East Blvd, Cleveland, Ohio 44106 is seeking a qualified contractor to provide all labor, materials, equipment, transportation, and supervision necessary to provide full-service, on-site Chiller Plant Maintenance to maintain and service all chillers, pumps, cooling towers, VFDs, and building automation controls necessary to cool and de-humidify the Medical Center for the health and safety of our patients, staff, medical equipment and visitors.\n\nScope\n\nThe vendor shall supply all labor, materials, equipment, clean up, transportation, and supervision necessary to perform all full-service, on-site maintenance, repairs, and replacement as scheduled and needed to the chiller plant chillers, cooling towers, pumps and any auxiliary equipment located at Louis Stokes Cleveland VA Medical Center to maintain the equipment in full operational status. This will include all equipment listed in Parts One, Two, Three, Four and Five. Vendor will have documented certified technicians and the ability to provide repair and replacement parts.\n\nThe Louis Stokes Cleveland VA Medical Center is expecting to add an additional/new chiller during Fiscal Year 2026. The new Chiller will be added to the scope of the contract.\n\nSpecific Tasks\n\nSee equipment list and maintenance description below:\n\n5.1. Task 1: Part One - Centrifugal Chillers\n\nNUMBER\nMFG\nMODEL\n\nTONS/ OUTPUT\n\nCH-I\nTRANE\nCVHF128NA\n1,200\n4160V\nCH-2\nTRANE\nCVHF128NA\n1,200\n4160V\nCH-3\nTRANE\nCVHF128NA\n1 ,200\n4160V\nCH-4\nTRANE\nCVHF1280\n1,200\n480V\nCH-5\nTRANE\nCVHF13DFA\n1,200\n480V\n\n5.1.1. Requirements for Centrifugal Chillers and Rotary Chillers:\n\nANNUAL Maintenance\n\nOnce a year, thorough preventative maintenance will be performed, including the following:\n\nFurnish oil filters and gaskets as required.\n\nPressure test as required using system pressure.\n\nRepair any leaks. Provide refrigerant leak reports to owners as required by EPA guidelines.\n\nDetailed inspection of purge system and thorough cleaning of purge compressor, purge oil separator, purge drum. Detailed inspection of purge system to include control circuit diagnostics, purge tank checkout and water removal, replace filter drier cores and clean the air-cooled condenser, if applicable.\n\nCheck the condition of contacts for wear, pitting, etc.\n\nCheck and calibrate safety controls, including all transmitters, flow meters, and all other monitoring devices.\n\nMeg compressor motor and oil pump. Check main starters and perform recommended testing (this includes all the chillers).\n\nCheck the main starters, tighten all starter terminals, and check contacts for wear.\n\nCheck overloads.\n\nTighten motor terminals and control panel terminals.\n\nClean oil strainer, replace filter and gasket where required. Tighten oil heater leads.\n\nCheck operation of vane position. Take oil sample and have analyzed for acid, moisture, and wear metal content.\n\nChange oil when so indicated by oil analysis unless done on annual schedule.\n\nProvide yearly recommended maintenance on refrigerant monitor along with calibration test, if applicable.\n\nReport any noted deficiencies.\n\nMonthly Maintenance:\n\nMonthly inspections to be made during the operating season, to include the following:\n\nAdjust operating and safety controls. Record settings.\n\nComplete operating log of temperatures, pressures, and voltages.\n\nChange oil in purge vacuum pumps when required.\n\nCheck operation of purge system.\n\nCheck operation of control circuit.\n\nCheck operating of lubricant system including oil pump and oil pressure regulator.\n\nCheck operation of motor and starter.\n\nCheck customer log with the operator, discuss operation of the machine generally.\n\nReport to operator any uncorrected deficiencies noted.\n\nMake operating log of temperatures, pressures, voltages, amperages, etc.\n\nCheck and adjust operating and safety controls.\n\nCheck operation of oil reservoir sump heater.\n\nCheck oil level and add as required.\n\nCheck operation of control circuit.\n\nCheck operating log with operator, discuss operation of the machine generally.\n\nCheck operation of motor and starter.\n\nSeasonal Start Up\n\nThe contractor will advise regarding the start of the month.\n\n1. Test motor (Meg).\n\n2. Start the machine, check controls, and calibrate.\n\n3. Complete operating log and record settings monthly.\n\n4. Check refrigerant and oil levels.\n\n5. Check purge operation.\n\n6. Check starter operation, voltage, and current.\n\nSet up operating log with operator, instruct, and advise troubleshooting techniques.\n\nAnalysis Services\n\nVarious diagnostic tests are to be performed depending on equipment duty and type. Reports with interpretation and recommendations are to be included.\n\n1. Oil sample and analysis for wear metals, acid content, and moisture. Sample to be taken two (2) times per year.\n\n2. Refrigerant analysis for acid and moisture content (as required).\n\nAnnual Operator Training\n\nTraining of operators or building engineers on the equipment covered, if required.\n\n1. Eight (8) hours of training per year for every boiler plant employee, up to 16 employees.\n\n2. Any un-utilized training costs will be reimbursed.\n\nParts Replacement\n\nAll parts needed to replace failed components on non-covered equipment will be offered at a discount percentage (30%). This does not include materials or components, such as refrigerant, oil, and other materials the contractor will provide to perform maintenance and repairs as emergencies or scheduled under annual maintenance, monthly maintenance, seasonal start up and analysis services.\n\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\nWritten Reports:\n\nProvided to customer representative following each regular inspection or emergency call.\n\n5.2. Task 2: Part Two Trace Automation & Controls\n\n5.2.1. Requirements for Tracer Automation Equipment Main Plant and Process Chiller Plant:\n\nA. Contractor will provide full-service coverage for regular systematic maintenance and parts, materials and labor for repairs, including all software support, defects in materials or manufacture, or due to normal wear and tear.\n\nB. Contractor will provide and install any new operational software and/or graphics with the latest revisions over the course of the contract.\n\nC. Unit maintenance and repair/replacement of PCs, Monitors, UPSs and associated equipment will be the liability of the contractor over the duration of the contract with no additional cost.\n\nD. Scheduled maintenance includes diagnosis of system performance, inspection, cleaning, adjustments, and other procedures as required by specifications according to system use and configuration.\n\nSemi-Annual Preventative Maintenance\n\nMaintenance/repair or replacement if required of the Building Automation Systems. Includes all operated valves, programming panels, BCU s, Tracer Output/Input panels and workstations associated with Energy Center equipment and operations, to include the following:\n\nMaster Station\n\nCheck the operating environment and clean the console. Check and clean the central processing unit and record input voltage.\n\n2. If necessitated by operational difficulties, run system diagnostics. Contractor will provide and install any new operational software and/or graphics with the most current version at no cost over the course of the contract.\n\n3. Clean and maintain BCU modules in both the Penthouse and Ambulatory Care.\n\n4. Check and clean CRTs and Printers.\n\n5. Perform complete system backup.\n\n6. Remote Stations and Field Hardware:\n\nVerify regulated power assembly and battery voltages, adjust as required.\n\nInspect cabinet at earth ground potential.\n\nVerify proper system electrical ground isolation.\n\nInspect interconnecting cables and electrical connections.\n\nVia terminal exercise-controlled devices with manual command functions and verify proper response of connected field hardware.\n\nCheck for alarms and overrides. Note specific alarm and override conditions for review with the owner personnel.\n\nClean external surfaces of the panel enclosure and associated field equipment units.\n\nReview system performance with Medical Centers designated contact.\n\nDiscuss specific parameter changes implemented as required.\n\nInspect interior surfaces and components of the panel enclosure and associated field equipment.\n\nEnsure all mounted devices add plug in components are securely in place.\n\nEvaluate binary and analog points for proper operation and reporting Perform a general performance review of all points.\n\nCheck individual critical points. Determine new or revised calibration coefficients as required.\n\nRecord any parameter values which are different than those shown on program listings.\n\nANNUAL OPERATOR TRAINING\n\nThe contractor will provide up to eight (8) hours of Tracer Summit on-site customer training, if requested.\n\nWRITTEN REPORTS\n\nProvided written reports to COR following each regular inspection or emergency call.\n\n5.3. Task 3: Part Three Chill Water/Tower Water Pumps, & Drives\nNUMBER\nMFG\nMODEL\nSERVICE\n\nCWP-I\nWEINMAN\n444TT\nCHILLED WATER\n2400GPM\n150HP\nCWP-2\nWEINMAN\n444TT\nCHILLED WATER\n2400GPM\n150HP\nCWP-3\nWEINMAN\n444TT\nCHILLED WATER\n2400GPM\n150HP\nCWP-4\nWEINMAN\n444TT\nCHILLED WATER\n2400GPM\n150HP\nCWP-5\nPACO\n444TT\nCHILLED WATER\n2400GPM\n150HP\nCWP-6\nPACO\n444TT\nCHILLED WATER\n2400GPM\n150HP\nVFD CWP-1\nDANFOSS/ GRAHAM\nVLT6000H190\nCHILLED WATER\n\n480V\nVFD CWP-2\nDANFOSS/ GRAHAM\nVLT6000H190\nCHILLED WATER\n\n480V\nVFD CWP-3\nDANFOSS/ GRAHAM\nVLT6000H190\nCHILLED WATER\n\n480V\nVFD CWP-4\nHONEYWELL\nSMART VFD\nHVFDSD3C1500G100\nCHILLED WATER\n\n480V\nVFD CWP-5\nEATON\nCFX9000\nCHILLED\nWATER\n\n480V\nVFD CWP-6\nEATON\nSVX9000\nCHILLED\nWATER\n\n480V\nTWP-I\nWEINMAN\n12L2\nTOWER\nWATER\n3600GPM\n100HP\nTWP-2\nWEINMAN\n12102\nTOWER\nWATER\n3600GPM\n100HP\nTWP-3\nWEINMAN\n12L2\nTOWER\nWATER\n3600GPM\n100HP\nTWP-4\nWEINMAN\n12L2\nTOWER\nWATER\n3600GPM\n100HP\nTWP-5\nPACO\nKP8012-56\nTOWER\nWATER\n3600GPM\n100HP\nTWP-6\nPACO\n8012\nTOWER\nWATER\n3600GPM\n100HP\nVFD-TWP-1\nDANFOSS/ GRAHAM\nMCD3075\nTOWER\nWATER\n\n480V\nVFD-TWP-2\nDANFOSS/ GRAHAM\nMCD3075\nTOWER\nWATER\n\n480V\nVFD-TWP-3\nDANFOSS/ GRAHAM\nMCD3075\nTOWER\nWATER\n\n480V\nVFD-TWP-4\nEATON\nSVX9000\nTOWER\nWATER\n\n480V\nVFD-TWP-5\nEATON\nCFX9000\nTOWER\nPUMP\n\n480V\nVFD-TWP-6\nEATON\nSVX9000\nTOWER\nPUMP\n\n480V\n\n5.3.1. Requirements for all Chill-Water, Tower/Condenser Water Pumps:\n\nMonthly Maintenance\n\nMonthly inspections to be made during the operating season, to include the following:\n\n1. Lubricate pump bearings per manufacturer s recommendations.\n\n2. Lubricate motor bearings per manufacturer s recommendations.\n\n3. Check the suction and discharge pressures.\n\n4. Check packing or mechanical seal and adjust as necessary.\n\n5. Check motor voltage and amperage.\n\nSEASONAL START UP\n\n1. Clean pump strainers.\n\n2. Lubricate pump bearings per manufacturer s recommendations.\n\n3. Lubricate motor bearings per manufacturer s recommendations.\n\n4. Tighten all nuts and bolts. Check motor mounts and vibration pads.\n\n5. Visually check pump alignment and coupling.\n\n6. Check motor operating conditions.\n\n7. Inspect electrical connections and contractors.\n\n8. check mechanical seals or pump packing.\n\n9. Operate pumps and check efficiency.\n\nPARTS REPLACEMENT\n\nAll parts or failed components of the equipment needed to be replaced will be provided by the vendor/contractor. This includes all materials or components, such as refrigerant, oil, and other materials the Contractor will provide to perform maintenance and repairs as scheduled under monthly maintenance and seasonal start up.\n\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\nWRITTEN REPORTS\n\nProvided to customer representative following each regular inspection or emergency call.\n\n5.3.2. Requirements for Adjustable or Variable Frequency Drives\n\nANNUAL MAINTENANCE: Once a year a thorough preventative maintenance schedule will be performed including the following:\n\nBase year initial base line reading of all VFDs will be provided in written report and subsequent yearly reports will be provided.\n\nRemove all debris, dust, or residue material from the drive enclosure.\n\nClean printed circuit boards with an approved cleaner or small brush.\n\nInspect for any lose plugs or ribbon cables.\n\nInspect for any damaged or missing items.\n\nLook for any overheated or charred components.\n\nLook for discolored components, smudges, or smoke residue.\n\nTighten all connections.\n\nInspect cooling fans for proper operation and change filters quarterly.\n\nCheck the continuity of all control circuit fuses.\n\nPerform diode test of the diode bridges.\n\nPerform continuity check of Debus and bus caps.\n\nPerform diode test of transistors.\n\nCheck and record AC line voltage.\n\nCheck and record motor output lead voltage for balanced supply.\n\nCheck and record Debus voltage.\n\nCompare data with previous tests to expose degradation of components.\n\nPART REPLACEMENT\n\nAll parts needed to replace failed components of the equipment will be provided by the contractor. This includes all materials or components, such as refrigerant, oil, and other materials the Contractor will provide to perform maintenance and repairs as scheduled under annual maintenance.\n\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\n5.4. Task 4: Part Four Cooling Towers, Cooling Tower Fan Drives, Semi-Annual Tower Cleaning, & Disinfection\n\nNUMBER\nMFG\nMODEL\nTONS\nMOTOR\n\nCT-I\nEVAPCO\nREP 224-018\n1200TONS\n2CELLS\n\nCT-2\nEVAPCO\nREP 224-018\n1200TONS\n2CELLS\n\nCT-3\nEVAPCO\nREP 224-018\n1200TONS\n2CELLS\n\nCT-4\nEVAPCO\nREP224-118\n1200TONS\n2CELLS\n\nCT-5\nEVAPCO\nAT224-118\n1200TONS\n2CELLS\n\nVFD-CT-I\nHONEYWELL SMART VFD\nHVFOSD306005100\nCOOLING TOWER\nFANS\n30\n60HZ\nVFD-CT-2\nDANFOSS/ GRAHAM\nVLT6000\nCOOLING TOWER\nFANS\n30\n60HZ\nVFD-CT-3\nDANFOSS/ GRAHAM\nVLT6000\nCOOLING\nTOWER\nFANS\n2 @ 30EA\n60HZ\nVFD-CT-4B\nEATON\nCFX9000\nCOOLING\nTOWER\nFAN\n1\n\n30HZ\nVFD-CT4A\nHONEYWELL\nNXS0300A1001\nCOOLING TOWER FAN\n1\n30HZ\nVFD-CT-5\nEATON\nSVX9000\nFANS\n2\n60HZ\n\n5.4.1. Requirements for Cooling Towers/Fluid Coolers\n\nMONTHLY MAINTENANCE\n\nMonthly inspections are to be made during the operating season, to include the following:\n\nInspect the fan, motor, and belt. Check the oil level and add oil as needed.\n\nCheck the intake strainer on cooling towers.\n\nCheck operating conditions. Adjust as required.\n\nCLEANING & DISINFECTION PROCESS\n\nTo be completed in early Spring (March/April) and late Fall (October/November) dependent on weather conditions and scheduled through the COR.\n\nThe following stages highlight the general approach for cleaning and disinfection of cooling water systems. Certain modifications may be required depending on system access, design, operation or the like. All stages in the clean and disinfection process shall require assistance from the Customer such as the operation engineer who is familiar with the system. All supplies and PPE will be contractor supplied. Proper LOTO will be utilized as needed.\n\nStage I\n\nPre-Clean Disinfection for the destruction of biofilms and pathogens\n\nAll cooling tower fans must be shut OFF and proper LOTO procedures in place prior to start of process, and all recirculation pumps must be ON.\n\nThe system is disinfected using an oxidizing biocide such as chlorine or an equivalent chemistry.\n\nA bio dispersant may also be added to help remove organic deposits and\nenhance disinfection.\n\nStage II\n\nMechanical Cleaning for surface sanitation and removal of deposits\nEach system cell and/or sump is isolated and drained for mechanical cleaning.\n\nEach system cell is pressure washed from top to bottom, internal and external, as is reasonably accessible to remove deposits.\n\nExceptional care is taken to remove deposits without damaging the fill pack.\n\nDeposits, including the sump if included in the scope, are removed for disposal. The Customer shall assist with disposal in the appropriate dumpsters or equivalents.\n\nStage III\n\nPost-Clean Disinfection for the destruction of dislodged biofilms and pathogens.\n\nAll cooling tower fans must be shut OFF, and all recirculation pumps must be ON.\n\nThe system is disinfected using an oxidizing biocide such as chlorine or equivalent chemistry.\n\nThe full water treatment program must be immediately resumed following the disinfection step to re-passivate system metallurgy.\n\nStage IV\n\nDocumentation and Certification\n\nThe cleaning and disinfection service is documented with a service report with photos and a certificate for a record of due diligence. Documentation supports a site risk reduction program for control of Legionella in cooling water systems.\n\nSEASONAL START UP/SHUTDOWN\n\nThe vendor will do a full check and start-up of all cooling towers and fluid coolers ensuring full operability.\n\nClean debris from the platform and surrounding area.\n\nClean water sump and check condition.\n\nCheck make-up valve operation and adjust accordingly.\n\nCheck and clean bleed-off line and overflow.\n\nClean tower strainers.\n\nCheck the condition of tower spray nozzles and eliminators.\n\nCheck sump heaters and thermostats for calibration and operation.\n\nCheck and adjust fan belts, as necessary.\n\nCheck for leaks.\n\nLubricate fan and motor bearings per manufacturer s recommendations.\n\nCheck the amperage on motors.\n\nInspect electrical connections, contractors, relays, and operating/safety controls.\n\nPARTS REPLACEMENT\n\nAll parts needed to replace failed components of the equipment will be provided by the vendor/contractor. This includes materials or components, such as refrigerant, oil, and other materials the Contractor will provide to perform maintenance and repairs as scheduled under monthly maintenance and seasonal start up.\n\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\nWRITTEN REPORTS\n\nProvided to customer representative following each regular inspection or emergency call.\n\nRequirements for Adjustable or Variable Frequency Drives\n\nANNUAL MAINTENANCE\n\nOnce a year a thorough preventative maintenance schedule will be performed including the following:\n\nBase year initial base line reading of all VFDs will be provided in written report and subsequent yearly reports will be provided.\n\nRemove all debris, dust, or residue material from the drive enclosure.\n\nClean printed circuit boards with an approved cleaner or small brush.\n\nInspect for any lose plugs or ribbon cables.\n\nInspect for any damaged or missing items.\n\nLook for any overheated or charred components.\n\nLook for discolored components, smudges, or smoke residue.\n\nTighten all connections.\n\nInspect cooling fans for proper operation and change filters quarterly.\n\nCheck the continuity of all control circuit fuses.\n\nPerform diode test of the diode bridges.\n\nPerform continuity check of Debus and bus caps.\n\nPerform diode test of transistors.\n\nCheck and record AC line voltage.\n\nCheck and record motor output lead voltage for balanced supply.\n\nCheck and record Debus voltage.\n\nCompare data with previous tests to expose degradation of components.\n\nPART REPLACEMENT\n\nAll parts needed to replace failed components of the equipment will be provided by the contractor. This includes all materials or components, such as refrigerant, oil, and other materials the Contractor will provide to perform maintenance and repairs as scheduled under annual maintenance.\n\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\n5.5. Task 5: Part 5 Rotary Chillers and Auxiliary Equipment (Process System)\n\nQTY\nDESCRIPTION\nMODEL\nMFG\nTYPE\n\n2\nCHILLERS 1,2\nRTWD250F\nTRANE\nDUAL COMPRESSOR\n134A\n2\nCHILLED WATER PUMPS\nEJMM2531T\nBALDOR\n25HP\n\n2\nCONDENSER PUMPS\nEJMM1531T\nBALDOR\n15HP\n\n4\nPUMP VFD S\n1,2,3,4\nTR200\nTRANE\n\n2\nDRY-COOLER CONDENSERS\nREPCM-ACC\nKRAMER\n8 FANS EACH\n\n1\nTRANE TRACER AUTOMATION SYSTEM\nMISC.\nPROCESS CHILLER\n\n5.5.1. Requirements for Rotary Chillers:\n\nANNUAL MAINTENANCE\n\nOnce a year, thorough preventative maintenance will be performed, including the following\n\nFurnish oil filters and gaskets as required.\n\nPressure test as required using system pressure.\n\nRepair any leaks. Provide refrigerant leak report to owners as required by EPA guidelines.\n\nDetailed inspection of purge system and thorough cleaning of purge compressor, purge oil separator, purge drum. Detailed inspection of purge system to include control circuit diagnostics, purge tank checkout and water removal, replace filter drier cores and clean the air-cooled condenser, if applicable.\n\nCheck the condition of contacts for wear, pitting, etc.\n\nCheck and calibrate safety controls, including all transmitters, flow meters, and all other monitoring devices.\n\nMeg compressor motor and oil pump. Check main starters and perform recommended testing (this includes all the chillers).\n\nCheck main starters and tighten all starter terminals and check contacts for wear.\n\nCheck overloads.\n\nTighten motor terminals and control panel terminals.\n\nClean oil strainer, replace filter and gasket where required. Tighten oil heater leads.\n\nCheck operation of vane position. Take oil sample and have analyzed for acid, moisture, and wear metal content.\n\nChange oil when so indicated by oil analysis unless done on annual schedule.\n\nProvide yearly recommended maintenance on refrigerant monitor along with calibration test, if applicable.\n\nReport any noted deficiencies.\n\nMONTHLY MAINTENANCE\n\nMonthly inspections to be made during the operating season, to include the following:\n\nAdjust operating and safety controls. Record settings.\n\nComplete operating log of temperatures, pressures, and voltages.\n\nChange oil in the purge vacuum pumps when required.\n\nCheck operation of purge system.\n\nCheck operation of control circuit.\n\nCheck operating of lubricant system including oil pump and oil pressure regulator.\n\nCheck operation of motor and starter.\n\nCheck customer log with operator, discuss operation of the machine generally.\n\nReport to operator any uncorrected deficiencies noted.\n\nMake operating log of temperatures, pressures, voltages, amperages, etc.\n\nCheck and adjust operating and safety controls.\n\nCheck operation of oil reservoir sump heater.\n\nCheck oil level and add as required.\n\nCheck operation of control circuit.\n\nheck operating log with operator, discuss operation of the machine generally.\n\nCheck operation of motor and starter.\n\nSEASONAL START UP\n\nThe contractor will advise regarding the start of the month.\n\nTest motor (Meg).\n\nStart machine, check controls, and calibrate.\n\nComplete operating log and record settings monthly.\n\nCheck refrigerant and oil levels.\n\nCheck purge operation.\n\nCheck starter operation, voltage, and current.\n\nSet up operating log with operator, instruct, and advise troubleshooting techniques.\n\nANALYSIS SERVICES\n\nVarious diagnostic tests are to be performed depending on equipment duty and type. Reports with interpretation and recommendations are to be included.\n\nOil sample and analysis for wear metals, acid content, and moisture. Sample to be taken two (2) times per year.\n\nRefrigerant analysis for acid and moisture content (as required).\n\nANNUAL OPERATOR TRAINING\n\nTraining of operators or building engineers on the equipment covered, if required.\n\nEight (8) hours of training per year for every boiler plant employee, up to 16 employees.\n\nAny unutilized training costs will be reimbursed.\n\nPARTS REPLACEMENT: All parts needed to replace failed components on non-covered equipment will be offered at a discount percentage (30%). This does not include materials or components, such as refrigerant, oil, and other materials the contractor will provide to perform maintenance and repairs as emergency or scheduled under annual maintenance, monthly maintenance, seasonal start up and analysis services.\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\nWRITTEN REPORTS\n\nProvided to customer representative following each regular inspection or emergency call.\n\n5.5.2. Requirements for Adjustable or Variable Frequency Drives\n\nANNUAL MAINTENANCE\n\nOnce a year a thorough preventative maintenance schedule will be performed including the following:\n\nBase year initial base line reading of all VFDs will be provided in written report and subsequent yearly reports will be provided.\n\nRemove all debris, dust, or residue material from the drive enclosure.\n\nClean printed circuit boards with an approved cleaner or small brush.\n\nInspect for any lose plugs or ribbon cables.\n\nInspect for any damaged or missing items.\n\nLook for any overheated or charred components.\n\nLook for discolored components, smudges, or smoke residue.\n\nTighten all connections.\n\nInspect cooling fans for proper operation and change filters quarterly.\n\nCheck the continuity of all control circuit fuses.\n\nPerform diode test of the diode bridges.\n\nPerform continuity check of Debus and bus caps.\n\nPerform diode test of transistors.\n\nCheck and record AC line voltage.\n\nCheck and record motor output lead voltage for balanced supply.\n\nCheck and record Debus voltage.\n\nCompare data with previous tests to expose degradation of components.\n\nPART REPLACEMENT\n\nAll parts needed to replace failed components of the equipment will be provided by the contractor. This includes all materials or components, such as refrigerant, oil, and other materials the Contractor will provide to perform maintenance and repairs as scheduled under annual maintenance.\n\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\nDeliverables\n\nThe contractor will provide the following:\n\nMonthly preventive maintenance/ repair reports on all chiller plant equipment.\nYearly refrigerant leak test reports.\nYearly chiller vibration reports.\nYearly oil test reports.\n\nCopies of all testing results along with certifications will be submitted to the COR.\n\nPerformance Monitoring\n\nThe COR will ensure maintenance and repairs are completed in accordance with the QASP submitted.\n\nCheck In Requirements\n\nThe Contractor Service Personnel and/or representative must report to the appropriate department Supervisor or designated point of contact (POC) to sign in with department staff before work begins. Additionally, one must submit any mobile media devices that would be used on the system for a virus scan. Upon completion of work, the Contractor Service Personnel and/or representative must report to the appropriate department Supervisor to brief that Supervisor orÂ related department staff point of contact (POC) if Supervisor is unavailable concerning completion of service, and then to sign out. At the end of each briefing, Contractor Service Personnel and/or representative will and must sign out.\n\nSecurity Requirements\n\nThe C&A requirements do not apply, and a Security Accreditation Package is not required.\n\n9.1. Dedicated personnel will be assigned solely to observe, interact, assist, and assure protection of VA sensitive information.\n\n9.2. Contractor employees providing services at VA facilities may undergo a security clearance in the form of a basic background investigation.Â\n\nGeneral Security\n\nContractors, contractor personnel, subcontractors, and subcontractor personnel shall be subject to the same Federal laws, regulations, standards, and VA Directives and Handbooks as VA and VA personnel regarding information and information system security.\n\nVA Information Custodial Language\n\n10.1. Information made available to the contractor or subcontractor by VA for the performance or administration of this contract or information developed by the contractor/subcontractor in performance or administration of the contract shall be used only for those purposes and shall not be used in any other way without the prior written agreement of the VA. This clause expressly limits the contractor/subcontractor's rights to use data as described in Rights in Data - General, FAR 52.227-14(d) (1).\n\n10.2. The contractor/subcontractor must store, transport, or transmit VA sensitive information in an encrypted form, using VA-approved encryption tools that are, at a minimum, FIPS 140-2 validated.\n\nGovernment-Furnished Equipment (GFE)/Government-Furnished Information (GFI)\n\nThere will be no government furnished equipment provided for the purposes of this contract.\n\nOther Pertinent Information or Special Considerations\n\nAny additional testing required outside this contract will require the contractor to submit a quote to COR and receive an approved PO before beginning work.\n\nIdentification of Possible Follow-on Work\n\nN/A\n\nIdentification of Potential Conflicts of Interest (COI)\n\nN/A\n\nIdentification of Non-Disclosure Requirements\n\nNot required\n\nInspection and Acceptance Criteria\n\nThe Contractor will be responsible for meeting timelines listed in this SOW. The COR shall make the final determination for satisfactory acceptance of work performed.\n\nRisk Control\n\nWork performed within the medical center may present health risks including exposure to illness and infection control. Contractor will take action to recognize and follow warning information throughout the facility.\n\nPlace of Performance\n\nLouis Stokes VA Medical Center\n10701 East Blvd.\nCleveland, Ohio 44106\n\nPeriod of Performance\n\nBase Year: Nov 1, 2025 Oct 31, 2026\nOption Year 1: Nov 1, 2026 Oct 31, 2027\nOption Year 2: Nov 1, 2027 Oct 31, 2028\nOption year 3: Nov 1, 2028 Oct 31, 2029\nOption Year 4: Nov 1, 2029 Oct 31, 2030\n\nStandard Work Hour\n\nThe Contractor shall perform all services required under this contract during the following standard work hours, except as otherwise authorized in writing by the Contracting Officer:\n\nStandard work hours are Monday through Friday, 8:00 AM to 4:30 PM Eastern Standard Time (EST). The Contractor shall ensure that all necessary personnel are available during these hours to perform the required services effectively. Any requests for deviations from these hours must be approved in advance by the COR. Any services that may cause additional charges or payments to be incurred must be scheduled in advance and approved by the Contracting Officer.\n\nPre-approved Overtime\n\nFor planned, non-emergent overtime work, the Contractor must seek pre-approval in writing from the COR and Contracting Officer. Rates and terms for pre-approved overtime will be detailed in the contract modification or separate PO.\n\nEmergency Work Authorization\n\nIn the event of an emergency that requires immediate attention beyond standard work hours, the Contractor shall respond as quickly as possible to address the issue. The Contractor must obtain verbal authorization from the Contracting Officer or COR before beginning any work.\n\nFederal Holidays\n\nThe following federal holidays are observed by the federal government. On these days, the Contractor is not required to perform services unless otherwise specified in the contract or approved in advance by the Contracting Officer.\n\nNew Year's Day January 1\nMartin Luther King Jr. Day Third Monday in January\nPresidents' Day Third Monday in February\nMemorial Day Last Monday in May\nJuneteenth June 19\nIndependence Day July 4\nLabor Day First Monday in September\nColumbus Day Second Monday in October\nVeterans Day November 11\nThanksgiving Day Fourth Thursday in November\nChristmas Day December 25\n\nIn addition to the above federal holidays, the President of the United States can decree new holidays. The Contractor shall observe any such additional holidays as declared.\n\nChanges to the Scope of the Contract\n\nAny changes to this SOW shall be authorized and approved only through written correspondence from the CO. A copy of each change will be kept in a project folder along with all other products of the project. Costs incurred by the contractor through the actions of parties other than the CO shall be borne by the contractor.\n\nThe Government reserves the right to add or remove any additional HVAC systems to the contract if necessary. Furthermore, the Government reserves the right to add, increase, or decrease chiller plant chillers, cooling towers, pumps and any auxiliary equipment to allow for fluctuations of client demand that are otherwise unknown at time of solicitation. The total contract value may increase up to 20% of the base award.","html":"Sources Sought Notice\n\nPage 4 of 4\n\n*= Required Field\nSources Sought Notice\n\nPage 1 of 4\nDepartment of Veterans Affairs\nSources Sought Notice   Chiller Plant Maintenance   Louis Stokes Cleveland VA Medical Center\n\nThis is a Sources Sought notice and not a request for quotes. This request is solely for the purpose of conducting market research to enhance VHA s understanding of the market s offered products, services and capabilities. The Government will not pay any costs for responses submitted in response to this Sources Sought.\nThe Department of Veterans Affairs (VA), VA Healthcare System, Network Contracting Office (NCO) 10, on behalf of Louis Stokes Cleveland VA Medical Center in Cleveland, Ohio, is conducting market research through this sources sought notice to seek sources that can provide Chiller Plant Maintenance and Services for the Louis Stokes Cleveland VA Medical Center.\n \nThe NAICS Code for this acquisition is 811310, size standard of $12,500,000. The product service code is J041. The contracting office is contemplating award of a Firm-Fixed-Price contract for this service.\n\nThis Sources Sought notice provides an opportunity for respondents to submit their notice of ability, and their available services in response to the requirement described below. Vendors are being invited to submit information relative to their potential of fulfilling the requirement below, in the form of a capability response that addresses the specific requirement identified in this Sources Sought. Pursuant to FAR Part 10, Market Research, the purpose of this notice is to determine if sources capable of satisfying the agency's requirements exists and to determine the commercial practices of company's engaged in providing the needed service. Pursuant to FAR Part 6 and FAR Part 19, competition and set-aside decisions may be based on the results of this market research. This notice in no way obligates the Government to any further action.\n\nThis is a \"REQUEST FOR INFORMATION\" only. Requests for a solicitation will not receive a response.\n\nDESCRIPTION\nThe Louis Stokes VA Medical Center located at 10701 East Blvd, Cleveland, Ohio 44106 is seeking a qualified contractor to provide all labor, materials, equipment, transportation, and supervision necessary to provide full-service, on-site Chiller Plant Maintenance to maintain and service all chillers, pumps, cooling towers, VFDs, and building automation controls necessary to cool and de-humidify the Medical Center for the health and safety of our patients, staff, medical equipment and visitors.\n\nGENERAL REQUIREMENTS\nPlease provide the requested information with any responses:\n\n1. Company Name and POC information.\n2. SAM.gov UEI number.\n3. GSA contract number if these services are offered on Federal Supply Schedule. \n4. Socioeconomic category (SDVOSB, VOSB, WOSB, 8a, Small Business or Large Business). If this contract is set-aside, it will be subject to the Limitations on Subcontracting rules per FAR 52.219-14, 13 CFR 125.6 and VAAR 852.219-75.\n5. Please provide a capability statement that addresses the organization s qualifications and ability to perform as a contractor for the work described below.\n6. Statement ensuring any licenses, insurances, training, certifications, or special accommodations necessary to perform this task will be met. If there are specific requirements, please provide rationale.\n7. Any questions, comments, or concerns, that may otherwise assist us.\n\nRESPONSE COMMITMENT\nPlease send all inquiries to: chad.kemper@va.gov. Phone calls will not be accepted.\n\nEligibility in participating in a future acquisition does not depend upon a response to this notice.\n?.## STATEMENT OF WORK (SOW)\n\nContract Title\n\nChiller Plant Maintenance\n\nBackground\n\nThe Louis Stokes VA Medical Center located at 10701 East Blvd, Cleveland, Ohio 44106 is seeking a qualified contractor to provide all labor, materials, equipment, transportation, and supervision necessary to provide full-service, on-site Chiller Plant Maintenance to maintain and service all chillers, pumps, cooling towers, VFDs, and building automation controls necessary to cool and de-humidify the Medical Center for the health and safety of our patients, staff, medical equipment and visitors.\n\nScope\n\nThe vendor shall supply all labor, materials, equipment, clean up, transportation, and supervision necessary to perform all full-service, on-site maintenance, repairs, and replacement as scheduled and needed to the chiller plant chillers, cooling towers, pumps and any auxiliary equipment located at Louis Stokes Cleveland VA Medical Center to maintain the equipment in full operational status. This will include all equipment listed in Parts One, Two, Three, Four and Five. Vendor will have documented certified technicians and the ability to provide repair and replacement parts.\n\nThe Louis Stokes Cleveland VA Medical Center is expecting to add an additional/new chiller during Fiscal Year 2026. The new Chiller will be added to the scope of the contract.\n\nSpecific Tasks\n\nSee equipment list and maintenance description below:\n\n5.1. Task 1: Part One - Centrifugal Chillers\n\nNUMBER\nMFG\nMODEL\n\nTONS/ OUTPUT\n\nCH-I\nTRANE\nCVHF128NA\n1,200\n4160V\nCH-2\nTRANE\nCVHF128NA\n1,200\n4160V\nCH-3\nTRANE\nCVHF128NA\n1 ,200\n4160V\nCH-4\nTRANE\nCVHF1280\n1,200\n480V\nCH-5\nTRANE\nCVHF13DFA\n1,200\n480V\n\n5.1.1. Requirements for Centrifugal Chillers and Rotary Chillers:\n\nANNUAL Maintenance\n\nOnce a year, thorough preventative maintenance will be performed, including the following:\n\nFurnish oil filters and gaskets as required.\n\nPressure test as required using system pressure.\n\nRepair any leaks. Provide refrigerant leak reports to owners as required by EPA guidelines.\n\nDetailed inspection of purge system and thorough cleaning of purge compressor, purge oil separator, purge drum. Detailed inspection of purge system to include control circuit diagnostics, purge tank checkout and water removal, replace filter drier cores and clean the air-cooled condenser, if applicable.\n\nCheck the condition of contacts for wear, pitting, etc.\n\nCheck and calibrate safety controls, including all transmitters, flow meters, and all other monitoring devices.\n\nMeg compressor motor and oil pump. Check main starters and perform recommended testing (this includes all the chillers).\n\nCheck the main starters, tighten all starter terminals, and check contacts for wear.\n\nCheck overloads.\n\nTighten motor terminals and control panel terminals.\n\nClean oil strainer, replace filter and gasket where required. Tighten oil heater leads.\n\nCheck operation of vane position. Take oil sample and have analyzed for acid, moisture, and wear metal content.\n\nChange oil when so indicated by oil analysis unless done on annual schedule. \n\nProvide yearly recommended maintenance on refrigerant monitor along with calibration test, if applicable.\n\nReport any noted deficiencies. \n\nMonthly Maintenance: \n\nMonthly inspections to be made during the operating season, to include the following:\n\nAdjust operating and safety controls. Record settings.\n\nComplete operating log of temperatures, pressures, and voltages.\n\nChange oil in purge vacuum pumps when required.\n\nCheck operation of purge system.\n\nCheck operation of control circuit.\n\nCheck operating of lubricant system including oil pump and oil pressure regulator.\n\nCheck operation of motor and starter.\n\nCheck customer log with the operator, discuss operation of the machine generally.\n\nReport to operator any uncorrected deficiencies noted.\n\nMake operating log of temperatures, pressures, voltages, amperages, etc.\n\nCheck and adjust operating and safety controls.\n\nCheck operation of oil reservoir sump heater.\n\nCheck oil level and add as required.\n\nCheck operation of control circuit.\n\nCheck operating log with operator, discuss operation of the machine generally.\n\nCheck operation of motor and starter. \n\nSeasonal Start Up\n\nThe contractor will advise regarding the start of the month. \n \n1. Test motor (Meg). \n \n2. Start the machine, check controls, and calibrate. \n \n3. Complete operating log and record settings monthly. \n \n4. Check refrigerant and oil levels. \n \n5. Check purge operation. \n \n6. Check starter operation, voltage, and current. \n\nSet up operating log with operator, instruct, and advise troubleshooting techniques. \n \nAnalysis Services\n\nVarious diagnostic tests are to be performed depending on equipment duty and type. Reports with interpretation and recommendations are to be included. \n\n1. Oil sample and analysis for wear metals, acid content, and moisture. Sample to be taken two (2) times per year. \n\n2. Refrigerant analysis for acid and moisture content (as required). \n\nAnnual Operator Training\n\nTraining of operators or building engineers on the equipment covered, if required. \n\n1. Eight (8) hours of training per year for every boiler plant employee, up to 16 employees. \n\n2. Any un-utilized training costs will be reimbursed. \n\nParts Replacement\n\nAll parts needed to replace failed components on non-covered equipment will be offered at a discount percentage (30%). This does not include materials or components, such as refrigerant, oil, and other materials the contractor will provide to perform maintenance and repairs as emergencies or scheduled under annual maintenance, monthly maintenance, seasonal start up and analysis services.\n\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\nWritten Reports:\n\nProvided to customer representative following each regular inspection or emergency call. \n\n5.2. Task 2: Part Two   Trace Automation & Controls\n\n5.2.1. Requirements for Tracer Automation Equipment Main Plant and Process Chiller Plant:\n\nA. Contractor will provide full-service coverage for regular systematic maintenance and parts, materials and labor for repairs, including all software support, defects in materials or manufacture, or due to normal wear and tear.\n\nB. Contractor will provide and install any new operational software and/or graphics with the latest revisions over the course of the contract.\n\nC. Unit maintenance and repair/replacement of PCs, Monitors, UPSs and associated equipment will be the liability of the contractor over the duration of the contract with no additional cost.\n \nD. Scheduled maintenance includes diagnosis of system performance, inspection, cleaning, adjustments, and other procedures as required by specifications according to system use and configuration.\n\nSemi-Annual Preventative Maintenance\n\nMaintenance/repair or replacement if required of the Building Automation Systems. Includes all operated valves, programming panels, BCU s, Tracer Output/Input panels and workstations associated with Energy Center equipment and operations, to include the following: \n\nMaster Station\n\nCheck the operating environment and clean the console. Check and clean the central processing unit and record input voltage.\n\n2. If necessitated by operational difficulties, run system diagnostics. Contractor will provide and install any new operational software and/or graphics with the most current version at no cost over the course of the contract.\n\n3. Clean and maintain BCU modules in both the Penthouse and Ambulatory Care.\n\n4. Check and clean CRTs and Printers.\n\n5. Perform complete system backup.\n\n6. Remote Stations and Field Hardware:\n\nVerify regulated power assembly and battery voltages, adjust as required.\n\nInspect cabinet at earth ground potential.\n\nVerify proper system electrical ground isolation.\n\nInspect interconnecting cables and electrical connections. \n\n Via terminal exercise-controlled devices with manual command functions and verify proper response of connected field hardware. \n\nCheck for alarms and overrides. Note specific alarm and override conditions for review with the owner personnel. \n\nClean external surfaces of the panel enclosure and associated field equipment units.\n \nReview system performance with Medical Centers designated contact.\n\nDiscuss specific parameter changes implemented as required.\n\nInspect interior surfaces and components of the panel enclosure and associated field equipment. \n\nEnsure all mounted devices add plug in components are securely in place. \n\nEvaluate binary and analog points for proper operation and reporting Perform a general performance review of all points. \n\nCheck individual critical points. Determine new or revised calibration coefficients as required. \n\nRecord any parameter values which are different than those shown on program listings. \n\nANNUAL OPERATOR TRAINING\n\nThe contractor will provide up to eight (8) hours of Tracer Summit on-site customer training, if requested.\n\nWRITTEN REPORTS\n\nProvided written reports to COR following each regular inspection or emergency call. \n\n5.3. Task 3: Part Three   Chill Water/Tower Water Pumps, & Drives\nNUMBER\nMFG\nMODEL\nSERVICE\n\n\nCWP-I\nWEINMAN\n444TT\nCHILLED WATER\n2400GPM\n150HP\nCWP-2\nWEINMAN\n444TT\nCHILLED WATER\n2400GPM\n150HP\nCWP-3\nWEINMAN\n444TT\nCHILLED WATER\n2400GPM\n150HP\nCWP-4\nWEINMAN\n444TT\nCHILLED WATER\n2400GPM\n150HP\nCWP-5\nPACO\n444TT\nCHILLED WATER\n2400GPM\n150HP\nCWP-6\nPACO\n444TT\nCHILLED WATER\n2400GPM\n150HP\nVFD CWP-1\nDANFOSS/ GRAHAM\nVLT6000H190\nCHILLED WATER\n\n480V\nVFD CWP-2\nDANFOSS/ GRAHAM\nVLT6000H190\nCHILLED WATER\n\n480V\nVFD CWP-3\nDANFOSS/ GRAHAM\nVLT6000H190\nCHILLED WATER\n\n480V\nVFD CWP-4\nHONEYWELL\nSMART VFD\nHVFDSD3C1500G100\nCHILLED WATER\n\n480V\nVFD CWP-5\nEATON\nCFX9000\nCHILLED\nWATER\n\n480V\nVFD CWP-6\nEATON\nSVX9000\nCHILLED\nWATER\n\n480V\nTWP-I\nWEINMAN\n12L2\nTOWER\nWATER\n3600GPM\n100HP\nTWP-2\nWEINMAN\n12102\nTOWER\nWATER\n3600GPM\n100HP\nTWP-3\nWEINMAN\n12L2\nTOWER\nWATER\n3600GPM\n100HP\nTWP-4\nWEINMAN\n12L2\nTOWER\nWATER\n3600GPM\n100HP\nTWP-5\nPACO\nKP8012-56\nTOWER\nWATER\n3600GPM\n100HP\nTWP-6\nPACO\n8012\nTOWER\nWATER\n3600GPM\n100HP\nVFD-TWP-1\nDANFOSS/ GRAHAM\nMCD3075\nTOWER\nWATER\n\n480V\nVFD-TWP-2\nDANFOSS/ GRAHAM\nMCD3075\nTOWER\nWATER\n\n480V\nVFD-TWP-3\nDANFOSS/ GRAHAM\nMCD3075\nTOWER\nWATER\n\n480V\nVFD-TWP-4\nEATON\nSVX9000\nTOWER\nWATER\n\n480V\nVFD-TWP-5\nEATON\nCFX9000\nTOWER\nPUMP\n\n480V\nVFD-TWP-6\nEATON\nSVX9000\nTOWER\nPUMP\n\n480V\n\n\n5.3.1. Requirements for all Chill-Water, Tower/Condenser Water Pumps:\n\nMonthly Maintenance\n\nMonthly inspections to be made during the operating season, to include the following:\n\n1. Lubricate pump bearings per manufacturer s recommendations.\n\n2. Lubricate motor bearings per manufacturer s recommendations.\n\n3. Check the suction and discharge pressures.\n\n4. Check packing or mechanical seal and adjust as necessary.\n\n5. Check motor voltage and amperage. \n\nSEASONAL START UP\n\n1. Clean pump strainers.\n\n2. Lubricate pump bearings per manufacturer s recommendations.\n\n3. Lubricate motor bearings per manufacturer s recommendations.\n\n4. Tighten all nuts and bolts. Check motor mounts and vibration pads.\n\n5. Visually check pump alignment and coupling.\n\n6. Check motor operating conditions.\n\n7. Inspect electrical connections and contractors.\n\n8. check mechanical seals or pump packing.\n\n9. Operate pumps and check efficiency. \n \nPARTS REPLACEMENT\n\nAll parts or failed components of the equipment needed to be replaced will be provided by the vendor/contractor. This includes all materials or components, such as refrigerant, oil, and other materials the Contractor will provide to perform maintenance and repairs as scheduled under monthly maintenance and seasonal start up.\n\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\nWRITTEN REPORTS\n\nProvided to customer representative following each regular inspection or emergency call. \n\n5.3.2. Requirements for Adjustable or Variable Frequency Drives\n\nANNUAL MAINTENANCE: Once a year a thorough preventative maintenance schedule will be performed including the following: \n\nBase year   initial base line reading of all VFDs will be provided in written report and subsequent yearly reports will be provided.\n\nRemove all debris, dust, or residue material from the drive enclosure.\n\nClean printed circuit boards with an approved cleaner or small brush.\n\nInspect for any lose plugs or ribbon cables.\n\nInspect for any damaged or missing items.\n\nLook for any overheated or charred components.\n\nLook for discolored components, smudges, or smoke residue.\n\nTighten all connections.\n\nInspect cooling fans for proper operation and change filters quarterly.\n\nCheck the continuity of all control circuit fuses.\n\nPerform diode test of the diode bridges.\n\nPerform continuity check of Debus and bus caps.\n\nPerform diode test of transistors.\n\nCheck and record AC line voltage.\n\nCheck and record motor output lead voltage for balanced supply.\n\nCheck and record Debus voltage.\n\nCompare data with previous tests to expose degradation of components.\n\nPART REPLACEMENT\n\nAll parts needed to replace failed components of the equipment will be provided by the contractor. This includes all materials or components, such as refrigerant, oil, and other materials the Contractor will provide to perform maintenance and repairs as scheduled under annual maintenance.\n\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\n5.4. Task 4: Part Four   Cooling Towers, Cooling Tower Fan Drives, Semi-Annual Tower Cleaning, & Disinfection\n\nNUMBER\nMFG\nMODEL\nTONS\nMOTOR\n\nCT-I\nEVAPCO\nREP 224-018\n1200TONS\n2CELLS\n\nCT-2\nEVAPCO\nREP 224-018\n1200TONS\n2CELLS\n\nCT-3\nEVAPCO\nREP 224-018\n1200TONS\n2CELLS\n\nCT-4\nEVAPCO\nREP224-118\n1200TONS\n2CELLS\n\nCT-5\nEVAPCO\nAT224-118\n1200TONS\n2CELLS\n\nVFD-CT-I\nHONEYWELL SMART VFD\nHVFOSD306005100\nCOOLING TOWER\nFANS\n30\n60HZ\nVFD-CT-2\nDANFOSS/ GRAHAM\nVLT6000\nCOOLING TOWER\nFANS\n30\n60HZ\nVFD-CT-3\nDANFOSS/ GRAHAM\nVLT6000\nCOOLING\nTOWER\nFANS\n2 @ 30EA\n60HZ\nVFD-CT-4B\nEATON\nCFX9000\nCOOLING\nTOWER\nFAN\n1\n\n30HZ\nVFD-CT4A\nHONEYWELL\nNXS0300A1001\nCOOLING TOWER FAN\n1\n30HZ\nVFD-CT-5\nEATON\nSVX9000\nFANS\n2\n60HZ\n\n5.4.1. Requirements for Cooling Towers/Fluid Coolers\n\nMONTHLY MAINTENANCE\n\nMonthly inspections are to be made during the operating season, to include the following: \n\nInspect the fan, motor, and belt. Check the oil level and add oil as needed.\n\nCheck the intake strainer on cooling towers.\n\nCheck operating conditions. Adjust as required. \n\nCLEANING & DISINFECTION PROCESS\n\nTo be completed in early Spring (March/April) and late Fall (October/November) dependent on weather conditions and scheduled through the COR.\n\nThe following stages highlight the general approach for cleaning and disinfection of cooling water systems. Certain modifications may be required depending on system access, design, operation or the like. All stages in the clean and disinfection process shall require assistance from the Customer such as the operation engineer who is familiar with the system. All supplies and PPE will be contractor supplied. Proper LOTO will be utilized as needed.\n\nStage I\n\nPre-Clean Disinfection for the destruction of biofilms and pathogens\n\nAll cooling tower fans must be shut OFF and proper LOTO procedures in place prior to start of process, and all recirculation pumps must be ON.\n\nThe system is disinfected using an oxidizing biocide such as chlorine or an equivalent chemistry.\n\nA bio dispersant may also be added to help remove organic deposits and \nenhance disinfection.\n\nStage II\n\nMechanical Cleaning for surface sanitation and removal of deposits\nEach system cell and/or sump is isolated and drained for mechanical cleaning.\n\nEach system cell is pressure washed from top to bottom, internal and external, as is reasonably accessible to remove deposits.\n\nExceptional care is taken to remove deposits without damaging the fill pack.\n\nDeposits, including the sump if included in the scope, are removed for disposal. The Customer shall assist with disposal in the appropriate dumpsters or equivalents.\n\nStage III\n\nPost-Clean Disinfection for the destruction of dislodged biofilms and pathogens.\n\nAll cooling tower fans must be shut OFF, and all recirculation pumps must be ON.\n\nThe system is disinfected using an oxidizing biocide such as chlorine or equivalent chemistry.\n\nThe full water treatment program must be immediately resumed following the disinfection step to re-passivate system metallurgy.\n\nStage IV\n \nDocumentation and Certification\n\nThe cleaning and disinfection service is documented with a service report with photos and a certificate for a record of due diligence. Documentation supports a site risk reduction program for control of Legionella in cooling water systems.\n\nSEASONAL START UP/SHUTDOWN\n\nThe vendor will do a full check and start-up of all cooling towers and fluid coolers ensuring full operability. \n\nClean debris from the platform and surrounding area.\n\nClean water sump and check condition.\n\nCheck make-up valve operation and adjust accordingly.\n\nCheck and clean bleed-off line and overflow.\n\nClean tower strainers.\n\nCheck the condition of tower spray nozzles and eliminators.\n\nCheck sump heaters and thermostats for calibration and operation.\n\nCheck and adjust fan belts, as necessary.\n\nCheck for leaks.\n\nLubricate fan and motor bearings per manufacturer s recommendations.\n\nCheck the amperage on motors.\n\nInspect electrical connections, contractors, relays, and operating/safety controls.\n \nPARTS REPLACEMENT\n\nAll parts needed to replace failed components of the equipment will be provided by the vendor/contractor. This includes materials or components, such as refrigerant, oil, and other materials the Contractor will provide to perform maintenance and repairs as scheduled under monthly maintenance and seasonal start up.\n\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\nWRITTEN REPORTS\n\nProvided to customer representative following each regular inspection or emergency call. \n\nRequirements for Adjustable or Variable Frequency Drives\n\nANNUAL MAINTENANCE\n\nOnce a year a thorough preventative maintenance schedule will be performed including the following: \n\nBase year   initial base line reading of all VFDs will be provided in written report and subsequent yearly reports will be provided.\n\nRemove all debris, dust, or residue material from the drive enclosure.\n\nClean printed circuit boards with an approved cleaner or small brush.\n\nInspect for any lose plugs or ribbon cables.\n\nInspect for any damaged or missing items.\n\nLook for any overheated or charred components.\n\nLook for discolored components, smudges, or smoke residue.\n\nTighten all connections.\n\nInspect cooling fans for proper operation and change filters quarterly.\n\nCheck the continuity of all control circuit fuses.\n\nPerform diode test of the diode bridges.\n\nPerform continuity check of Debus and bus caps.\n\nPerform diode test of transistors.\n\nCheck and record AC line voltage.\n\nCheck and record motor output lead voltage for balanced supply.\n\nCheck and record Debus voltage.\n\nCompare data with previous tests to expose degradation of components.\n\nPART REPLACEMENT\n\nAll parts needed to replace failed components of the equipment will be provided by the contractor. This includes all materials or components, such as refrigerant, oil, and other materials the Contractor will provide to perform maintenance and repairs as scheduled under annual maintenance.\n\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\n5.5. Task 5: Part 5   Rotary Chillers and Auxiliary Equipment (Process System)\n \nQTY\nDESCRIPTION\nMODEL\nMFG\nTYPE\n\n2\nCHILLERS 1,2\nRTWD250F\nTRANE\nDUAL COMPRESSOR\n134A\n2\nCHILLED WATER PUMPS\nEJMM2531T\nBALDOR\n25HP\n\n2\nCONDENSER PUMPS\nEJMM1531T\nBALDOR\n15HP\n\n4\nPUMP VFD S\n1,2,3,4\nTR200\nTRANE\n\n\n2\nDRY-COOLER CONDENSERS\nREPCM-ACC\nKRAMER\n8 FANS EACH\n\n1\nTRANE TRACER AUTOMATION SYSTEM\nMISC.\nPROCESS CHILLER\n\n\n\n5.5.1. Requirements for Rotary Chillers:\n\nANNUAL MAINTENANCE\n\nOnce a year, thorough preventative maintenance will be performed, including the following\n\nFurnish oil filters and gaskets as required.\n\nPressure test as required using system pressure.\n\nRepair any leaks. Provide refrigerant leak report to owners as required by EPA guidelines.\n\nDetailed inspection of purge system and thorough cleaning of purge compressor, purge oil separator, purge drum. Detailed inspection of purge system to include control circuit diagnostics, purge tank checkout and water removal, replace filter drier cores and clean the air-cooled condenser, if applicable.\n\nCheck the condition of contacts for wear, pitting, etc.\n\nCheck and calibrate safety controls, including all transmitters, flow meters, and all other monitoring devices.\n\nMeg compressor motor and oil pump. Check main starters and perform recommended testing (this includes all the chillers).\n\nCheck main starters and tighten all starter terminals and check contacts for wear.\n\nCheck overloads. \n\nTighten motor terminals and control panel terminals.\n\nClean oil strainer, replace filter and gasket where required. Tighten oil heater leads.\n\nCheck operation of vane position. Take oil sample and have analyzed for acid, moisture, and wear metal content.\n\nChange oil when so indicated by oil analysis unless done on annual schedule.\n\nProvide yearly recommended maintenance on refrigerant monitor along with calibration test, if applicable.\n\nReport any noted deficiencies. \n\nMONTHLY MAINTENANCE\n\nMonthly inspections to be made during the operating season, to include the following: \n\nAdjust operating and safety controls. Record settings.\n\nComplete operating log of temperatures, pressures, and voltages.\n\nChange oil in the purge vacuum pumps when required.\n\nCheck operation of purge system.\n\nCheck operation of control circuit.\n\nCheck operating of lubricant system including oil pump and oil pressure regulator.\n\nCheck operation of motor and starter.\n\nCheck customer log with operator, discuss operation of the machine generally. \n\nReport to operator any uncorrected deficiencies noted.\n\nMake operating log of temperatures, pressures, voltages, amperages, etc.\n\nCheck and adjust operating and safety controls.\n\nCheck operation of oil reservoir sump heater.\n\nCheck oil level and add as required.\n\nCheck operation of control circuit.\n\nheck operating log with operator, discuss operation of the machine generally.\n\nCheck operation of motor and starter. \n\nSEASONAL START UP\n\nThe contractor will advise regarding the start of the month. \n\nTest motor (Meg).\n\nStart machine, check controls, and calibrate.\n\nComplete operating log and record settings monthly.\n\nCheck refrigerant and oil levels.\n\nCheck purge operation.\n\nCheck starter operation, voltage, and current.\n\nSet up operating log with operator, instruct, and advise troubleshooting techniques. \n \nANALYSIS SERVICES\n\nVarious diagnostic tests are to be performed depending on equipment duty and type. Reports with interpretation and recommendations are to be included. \n\nOil sample and analysis for wear metals, acid content, and moisture. Sample to be taken two (2) times per year.\n\nRefrigerant analysis for acid and moisture content (as required). \n\nANNUAL OPERATOR TRAINING\n\nTraining of operators or building engineers on the equipment covered, if required. \n\nEight (8) hours of training per year for every boiler plant employee, up to 16 employees.\n\nAny unutilized training costs will be reimbursed. \n\nPARTS REPLACEMENT: All parts needed to replace failed components on non-covered equipment will be offered at a discount percentage (30%). This does not include materials or components, such as refrigerant, oil, and other materials the contractor will provide to perform maintenance and repairs as emergency or scheduled under annual maintenance, monthly maintenance, seasonal start up and analysis services.\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\nWRITTEN REPORTS\n\nProvided to customer representative following each regular inspection or emergency call. \n\n5.5.2. Requirements for Adjustable or Variable Frequency Drives\n\nANNUAL MAINTENANCE\n\nOnce a year a thorough preventative maintenance schedule will be performed including the following: \n\nBase year   initial base line reading of all VFDs will be provided in written report and subsequent yearly reports will be provided.\n\nRemove all debris, dust, or residue material from the drive enclosure.\n\nClean printed circuit boards with an approved cleaner or small brush.\n\nInspect for any lose plugs or ribbon cables.\n\nInspect for any damaged or missing items.\n\nLook for any overheated or charred components.\n\nLook for discolored components, smudges, or smoke residue.\n\nTighten all connections.\n\nInspect cooling fans for proper operation and change filters quarterly.\n\nCheck the continuity of all control circuit fuses.\n\nPerform diode test of the diode bridges.\n\nPerform continuity check of Debus and bus caps.\n\nPerform diode test of transistors.\n\nCheck and record AC line voltage.\n\nCheck and record motor output lead voltage for balanced supply.\n\nCheck and record Debus voltage.\n\nCompare data with previous tests to expose degradation of components.\n\nPART REPLACEMENT\n\nAll parts needed to replace failed components of the equipment will be provided by the contractor. This includes all materials or components, such as refrigerant, oil, and other materials the Contractor will provide to perform maintenance and repairs as scheduled under annual maintenance.\n\nAny parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding.\n\nDeliverables\n\nThe contractor will provide the following:\n\nMonthly preventive maintenance/ repair reports on all chiller plant equipment.\nYearly refrigerant leak test reports.\nYearly chiller vibration reports.\nYearly oil test reports.\n\nCopies of all testing results along with certifications will be submitted to the COR. \n\nPerformance Monitoring\n\nThe COR will ensure maintenance and repairs are completed in accordance with the QASP submitted. \n\nCheck   In Requirements\n\nThe Contractor Service Personnel and/or representative must report to the appropriate department Supervisor or designated point of contact (POC) to sign in with department staff before work begins. Additionally, one must submit any mobile media devices that would be used on the system for a virus scan. Upon completion of work, the Contractor Service Personnel and/or representative must report to the appropriate department Supervisor to brief that Supervisor orÂ related department staff point of contact (POC) if Supervisor is unavailable concerning completion of service, and then to sign out. At the end of each briefing, Contractor Service Personnel and/or representative will and must sign out.\n\nSecurity Requirements\n\nThe C&A requirements do not apply, and a Security Accreditation Package is not required.\n\n9.1. Dedicated personnel will be assigned solely to observe, interact, assist, and assure protection of VA sensitive information. \n\n9.2. Contractor employees providing services at VA facilities may undergo a security clearance in the form of a basic background investigation.Â \n\nGeneral Security\n\nContractors, contractor personnel, subcontractors, and subcontractor personnel shall be subject to the same Federal laws, regulations, standards, and VA Directives and Handbooks as VA and VA personnel regarding information and information system security.\n\nVA Information Custodial Language\n\n10.1. Information made available to the contractor or subcontractor by VA for the performance or administration of this contract or information developed by the contractor/subcontractor in performance or administration of the contract shall be used only for those purposes and shall not be used in any other way without the prior written agreement of the VA. This clause expressly limits the contractor/subcontractor's rights to use data as described in Rights in Data - General, FAR 52.227-14(d) (1).\n\n10.2. The contractor/subcontractor must store, transport, or transmit VA sensitive information in an encrypted form, using VA-approved encryption tools that are, at a minimum, FIPS 140-2 validated.\n\nGovernment-Furnished Equipment (GFE)/Government-Furnished Information (GFI)\n\nThere will be no government furnished equipment provided for the purposes of this contract.\n\nOther Pertinent Information or Special Considerations\n\nAny additional testing required outside this contract will require the contractor to submit a quote to COR and receive an approved PO before beginning work.\n\nIdentification of Possible Follow-on Work\n\nN/A\n\nIdentification of Potential Conflicts of Interest (COI)\n\nN/A\n\nIdentification of Non-Disclosure Requirements \n\nNot required\n\nInspection and Acceptance Criteria\n\nThe Contractor will be responsible for meeting timelines listed in this SOW. The COR shall make the final determination for satisfactory acceptance of work performed.\n\nRisk Control\n\nWork performed within the medical center may present health risks including exposure to illness and infection control. Contractor will take action to recognize and follow warning information throughout the facility. \n\nPlace of Performance\n\nLouis Stokes VA Medical Center\n10701 East Blvd.\nCleveland, Ohio 44106 \n\nPeriod of Performance\n\nBase Year: Nov 1, 2025   Oct 31, 2026\nOption Year 1:  Nov 1, 2026   Oct 31, 2027\nOption Year 2:  Nov 1, 2027   Oct 31, 2028\nOption year 3:  Nov 1, 2028   Oct 31, 2029\nOption Year 4:  Nov 1, 2029   Oct 31, 2030\n\nStandard Work Hour\n\nThe Contractor shall perform all services required under this contract during the following standard work hours, except as otherwise authorized in writing by the Contracting Officer:\n\nStandard work hours are Monday through Friday, 8:00 AM to 4:30 PM Eastern Standard Time (EST). The Contractor shall ensure that all necessary personnel are available during these hours to perform the required services effectively. Any requests for deviations from these hours must be approved in advance by the COR. Any services that may cause additional charges or payments to be incurred must be scheduled in advance and approved by the Contracting Officer.\n\nPre-approved Overtime\n\nFor planned, non-emergent overtime work, the Contractor must seek pre-approval in writing from the COR and Contracting Officer. Rates and terms for pre-approved overtime will be detailed in the contract modification or separate PO.\n\nEmergency Work Authorization\n\nIn the event of an emergency that requires immediate attention beyond standard work hours, the Contractor shall respond as quickly as possible to address the issue. The Contractor must obtain verbal authorization from the Contracting Officer or COR before beginning any work.\n\nFederal Holidays\n\nThe following federal holidays are observed by the federal government. On these days, the Contractor is not required to perform services unless otherwise specified in the contract or approved in advance by the Contracting Officer.\n\nNew Year's Day   January 1\nMartin Luther King Jr. Day   Third Monday in January\nPresidents' Day   Third Monday in February\nMemorial Day   Last Monday in May\nJuneteenth   June 19\nIndependence Day   July 4\nLabor Day   First Monday in September\nColumbus Day   Second Monday in October\nVeterans Day   November 11\nThanksgiving Day   Fourth Thursday in November\nChristmas Day   December 25\n\nIn addition to the above federal holidays, the President of the United States can decree new holidays. The Contractor shall observe any such additional holidays as declared.\n\nChanges to the Scope of the Contract\n\nAny changes to this SOW shall be authorized and approved only through written correspondence from the CO. A copy of each change will be kept in a project folder along with all other products of the project. Costs incurred by the contractor through the actions of parties other than the CO shall be borne by the contractor.\n\nThe Government reserves the right to add or remove any additional HVAC systems to the contract if necessary. Furthermore, the Government reserves the right to add, increase, or decrease chiller plant chillers, cooling towers, pumps and any auxiliary equipment to allow for fluctuations of client demand that are otherwise unknown at time of solicitation. The total contract value may increase up to 20% of the base award.","origin":"detail"},"contacts":[{"name":"Chad Kemper","role":"primary","email":"chad.kemper@va.gov","phone":"(937) 268-6511 ext. 4541","title":"Contracting Officer"}],"place_of_performance":{"zip":"44106-1702","city":{"name":"Cleveland"},"state":{"code":"OH","name":"Ohio"},"street":"Department of Veterans Affairs Louis Stokes Cleveland VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"10701 East Blvd"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"naics_codes":["811310"],"award":{"awardee":{}},"attachments":[{"resource_id":"a3b4cb1ce15e4e82891ea39e3a46f58a","name":"36C25026Q0018.docx","kind":"file","mime_type":".docx","size_bytes":66693,"posted_at":"2025-08-29T19:06:16.621Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/a3b4cb1ce15e4e82891ea39e3a46f58a/download","mirrored":false}],"awards":[],"related":[{"key":"36C25027Q0014","latest_notice_id":"b13cc87179e947e7b42da2de44a6bde1","title":"J061--541 Electrical Power Distribution Equipment Testing, Inspection, and Maintenance - VAMC Cleveland","solicitation_number":"36C25027Q0014","notice_type":"k","first_type":"k","first_posted":"2026-10-09","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"238210","psc":"J061","set_aside":"SBA","state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C25027Q0123","latest_notice_id":"fb53a332644a4c8fa983bf28c8643d2d","title":"S222--Sources Sought - Hazardous Waste Removal/Disposal Northeast Ohio VA Healthcare System - Cleveland, OH","solicitation_number":"36C25027Q0123","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T18:30:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"562112","psc":"S222","set_aside":null,"state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C25027B0009","latest_notice_id":"85b83d408f1f422885991142c2734b45","title":"Z1DA--FY27 NRM - VISN Base Modernize Nurse Call - 539-23-101","solicitation_number":"36C25027B0009","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"},{"key":"36C25027B0008","latest_notice_id":"5afe716a38494a6f84b1e84205805f86","title":"Z1DA--FY27 NRM - VISN Base Install Roof Equipment Railings - 539-22-206","solicitation_number":"36C25027B0008","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"},{"key":"36C25027B0005","latest_notice_id":"2cb4a6354be04cc89c5d6125945b1892","title":"Z1DA--***FY27 Requirement*** First Floor X Ray - Room CC157 553-CSI-022","solicitation_number":"36C25027B0005","notice_type":"p","first_type":"p","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"MI","county":"26163","county_name":"Wayne County","city":"2622000","city_name":"Detroit","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"}],"similar_open":[{"key":"36C25027Q0125","latest_notice_id":"e5df74f59da04348802d00e8183b9b8c","title":"J061--Emergency Switchgear Repairs PWS 539","solicitation_number":"36C25027Q0125","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":2,"due_at":"2026-12-07T15:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"811310","psc":"J061","set_aside":null,"state":"OH","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_street","state_evidence":"CINCINNATI VAMC 3200 VINE STREET CINCINNATI, OH 45220","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"W50S6Y27RA002","latest_notice_id":"87cba3e75e354d12990453adb59fe26e","title":"Halon Bottle Inspection","solicitation_number":"W50S6Y27RA002","notice_type":"o","first_type":"r","first_posted":"2026-11-07","last_posted":"2026-11-20","notices":6,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W50S6Y","office_name":"W7M2 USPFO ACTIVITY FLANG 125","naics":"811310","psc":"J042","set_aside":"SBA","state":"FL","county":"12031","county_name":"Duval County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"N3225327Q0011","latest_notice_id":"e4f2bdc21bab431d8dddd03dc4c01ccf","title":"Dry Dock Flow Meter Service","solicitation_number":"N32253-27-Q-0011","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-24","notices":2,"due_at":"2026-11-27T18:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N32253","office_name":"PEARL HARBOR NAVAL SHIPYARD IMF","naics":"811310","psc":"J049","set_aside":null,"state":"HI","county":"15003","county_name":"Honolulu County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":58,"indexable":false}