{"canonical":"https://sealedbidder.com/opportunities/36c25025q0899","key":"36C25025Q0899","url":"https://sealedbidder.com/opportunities/36c25025q0899","title":"J042--Fire Suppression System Maintenance & Repairs","solicitation_number":"36C25025Q0899","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-09-10T14:00:00Z","first_posted":"2025-09-02","last_posted":"2025-09-02","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"238220","psc":"J042","set_aside":null,"place_state":"MI","place_scope":"site","site":null,"place_state_source":"sam_zip","place_evidence":null,"place_county":"26145","place_county_name":"Saginaw County","place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"8c3149dacfd740bb9b6ad4fa0b64bddc","title":"J042--Fire Suppression System Maintenance & Repairs","solicitation_number":"36C25025Q0899","notice_type":"r","base_type":"r","posted":"2025-09-02","posted_at":"2025-09-02T12:12:05.649Z","due_at":"2025-09-10T14:00:00Z","due_date":"2025-09-10","cancelled":false,"archived":true,"archive_date":"2025-10-10","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/8c3149dacfd740bb9b6ad4fa0b64bddc/view","enriched":true,"history":[{"index":3,"title":"J042--Fire Suppression System Maintenance & Repairs","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-02T12:12:05.649Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"8c3149dacfd740bb9b6ad4fa0b64bddc","solicitation_number":"36C25025Q0899"}]}],"latest_notice_id":"8c3149dacfd740bb9b6ad4fa0b64bddc","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-09-02","posted_at":"2025-09-02T12:12:05.649Z","created_at":"2025-09-02T12:12:03.430Z","modified_at":"2025-10-11T04:04:28.656Z","response_deadline":{"raw":"2025-09-10T10:00:00-04:00","utc":"2025-09-10T14:00:00Z","date":"2025-09-10","time":"10:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/8c3149dacfd740bb9b6ad4fa0b64bddc/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"J042--Fire Suppression System Maintenance & Repairs","agency":{"office":{"code":"36C250","name":"250-NETWORK CONTRACT OFFICE 10 (36C250)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"organization_id":"100167099","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-10-10","archive_type":"auto_custom"},"history":[{"index":3,"title":"J042--Fire Suppression System Maintenance & Repairs","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-02T12:12:05.649Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"8c3149dacfd740bb9b6ad4fa0b64bddc","solicitation_number":"36C25025Q0899"}],"contacts":[{"name":"Jeannie Ortiz","role":"primary","email":"jeanne.ortiz@va.gov","phone":"NO PHONE CALLS ACCEPTED","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"8c3149dacfd740bb9b6ad4fa0b64bddc","lineage_id":"8c3149dacfd740bb9b6ad4fa0b64bddc","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-01T04:16:36.754487072Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"ed50506b224d0cbc34bc8466daf3cdae09480da4db547d672f345fe840ae2d2e","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-01T04:16:36.754487072Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"This is a Sources Sought Notice for Fire Suppression System Maintenance, Repair, Testing & Inspection services as identified in the Statement of Work (SOW) for the Saginaw VA Medical Center in Saginaw, Michigan. The contractor shall furnish all necessary tools, parts, labor, supplies, materials, equipment, supervision and transportation necessary to furnish the services noted below.\n\nA DRAFT SOW is attached to this notice and is subject to change should a solicitation be issued as a result of this notice. \n\nPlease respond if you have the ability and actual intention to complete this requirement. All of the following information is required in your response:\n\nDUNS NUMBER\nSAM UEI NUMBER\nGSA Contract Number\nCapabilities Statement\nConfirmation of actual intent to submit an offer should an RFQ be posted in future\nCompany name and address\nPoint of contact information (name, phone, email)\nSocioeconomic size status (example: large business, small business, WOSB, SDVOSB, etc.)\n\nThis Sources Sought Notice is intended to locate any business capable of performance.\n\nThe anticipated NAICS Code for this requirement is 238220.\n\nThis is not a Request for Quotation and quotes shall not be reviewed at this time.\n\nThe Government shall not be responsible for any costs incurred by the contractor because of this Sources Sought Notice.\n\nThis notice shall not be construed as a commitment by the Government to ultimately award a contract, nor does it restrict the Government to any particular acquisition approach. All information submitted in response to this announcement is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government.\n\nResponses shall be submitted to Jeanne Ortiz at jeanne.ortiz@va.gov by Wednesday, September 10, 2025, at 10:00 AM Eastern Time (ET). Responses MUST include 36C25025Q0899 in the subject line. PHONE CALLS SHALL NOT BE ACCEPTED FOR THIS NOTICE.\n\nDRAFT STATEMENT OF WORK\n\nGENERAL\nContractor shall provide all necessary labor, materials, and expertise to perform quarterly, semi-annual (every six months) and annual maintenance, testing, inspection and repair services on the Fire Suppression Systems located at the Saginaw VA (SVA) Medical Center, 1500 Weiss Street, Saginaw, MI 48602. \n\nCONFORMANCE STANDARDS\nContractor shall perform inspections in accordance with the most current editions of (OEM) \nmaintenance manuals, most recently published versions of the following NFPA codes, \nNFPA 01, Fire Code\nNFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems \nNFPA 72, National Fire Alarm and Signaling Code\nNFPA 75, Standard for the Fire Protection of Information Technology Equipment\nNFPA 80, Standard for Fire Doors and Other Opening Protectives\nNFPA 92, Standard for Smoke Control Systems\nNFPA 105, Standard for Smoke Door Assemblies and Other Opening Protectives\nNFPA 2001, Standard on Clean Agent Fire Extinguishing Systems,\nand additional regulatory requirements as prescribed by the Joint Commission on the Accreditation of Healthcare Organizations (JCAHO).\n\nSCOPE OF WORK\nContractor shall develop a written testing plan to include ALL system components, showing the periodic frequency of inspections/testing and upcoming inspection/testing dates for the contract year for 100% of all fire alarm system devices.\n\nContractor shall provide the Service POC/COR with the completed testing plan ten (10) business days after contract is awarded, with a schedule of tentative testing dates for all components for the contract year.\n\nContractor shall complete a  SAFE WORK  permit provided by the facility. This permit shall be signed by the Service POC/COR or an authorized individual from Engineering Service. The permit shall be posted in Engineering and at the fire alarm panel. The permit authorizes the Contractor to remove the fire alarm system from service for testing and repair purposes. If an actual event presents during testing, Contractor is responsible for notifying Service POC/COR or an authorized individual from Engineering Service.\n\nContractor shall participate in an online monthly meeting to discuss completed inspections, inspection reports, future inspections, payment status, contractor compliance with the contract and facility compliance. Contractor shall provide a monthly agenda and provide thorough meeting minutes within seven (7) business days of the meeting.\n\nContractor is responsible for scheduling and completing all inspections, testing and planned maintenance to meet current NFPA and JCAHO standards within standard hours of operation.\n\nContractor shall notify Service POC/COR by phone and email, at least one month prior to conducting inspections and/or planned maintenance.\n\nServices shall also include the following:\nSystematic examination of all system components.\nContractor shall perform testing, cleaning, adjusting of all components as necessary to keep the system in reliable condition and proper working order.\nContractor shall furnish all tools, and cleaning materials, and parts required to perform inspections and testing.\nEmergency Service: Contractor shall respond within six (6) hours upon notification of system trouble.\nInstallation of two (2) tamper switches on Building 9 Backflow preventer in the base year only. \n\nContractor shall contact Service POC/COR by phone, prior to, and upon completion of, work. Contractor shall provide work ticket/report. Work ticket shall include complete description of the work performed and parts replaced. Contractor staff shall review inspection reports with the Service POC/COR at the end of each day and confirm all devices have been tested.\n\nThe following is a list of systems and components that shall be maintained and tested to include, but not limited to, the following:\nInitiating devices to include:\nFire Hydrants\nFire department Connections\nHose Connections\nMain drains\nDrains\nFire Sprinkler Water Flow Switches\nFire sprinkler valve supervisory switches\nAir Compressors\nFire sprinkler hi/low air supervisory switches\nPIV s\nGauges\nControls Valves\nCheck valves\nStandpipes\nAuxiliary devices, to include flow switch bells \n\nEXCLUSIONARY ITEMS: Fire hydrants, air compressors, & fire extinguisher replacements. Contractor to provide a quote. These will be processed under a separate purchase order.\n\nContractor shall submit a quarterly report to Service POC/COR to include, but not limited to, the following information: (This is in addition to uploading reports into  Building Reports )\nTesting Schedule:\nBuilding number.\nSystem type tested.\nWhat was tested.\nDetailed report:\nBuilding number.\nLocation of device.\nType of Device.\nTest Results   original and current.\nZone (Zone FACP).\nCode (Chime Code).\nQuarter.\n6 months.\nYear.\nDate.\nComments.\nFire Alarm Discrepancy Report:\nBuilding Number.\nDevice and location.\nType of Discrepancy.\n\nThese publications shall be adhered to when conducting repairs, testing, maintenance and inspections:\nManufacturer s maintenance manuals.\nManufacturer s recommendations.\nNational Fire Protection Association Standards. (NFPA 25, 72 & 105)\nNational Electrical Code (NEC).\nNational Fire Code.\nJCAHO Requirements. (VA will provide. Contact Service POC/COR).\n\nFire Sprinkler and Suppression System Components (An initial inventory during first annual fire alarm inspection and test shall be conducted by contractor to confirm existing numbers.)\nFire Sprinkler and Suppression Systems include the following components:\nITEM\nQTY\nUNIT\nWATER FLOWS\n61\nEA\nSPRINKLER TAMPER SWITCHES\n78\nEA\nCONTROL VALVE\n81\nEA\nSPRINKLER RISER (WET) \n9\nEA\nSPRINKLER RISER (DRY)\n3\nEA\nFIRE HYDRANTS\n10\nEA\nFIRE DEPARTMENT CONNECTIONS (FDC S)\n9\nEA\nHOSE CONNECTIONS\n46\nEA\nSTANDPIPE\n7\nEA\nSPRINKLER HEAD BOXES (SPARES)\n10\nEA\nSPRINKLER HEAD SPARES\n40\nEA\nCHECK VALVE\n19\nEA\nGAUGES\n\n\nDRAINS\n59\nEA\nPIV\n39\nEA\nMAIN DRAIN (INTO BUILDINGS)\n6\nEA\nFIRE EXTINGUISHER (2.5 LB ABC)\n9\nEA\nFIRE EXTINGUISHER (5 LB ABC)\n1\nEA\nFIRE EXTINGUISHER (10 LB ABC)\n64\nEA\nFIRE EXTINGUISHER (10 HALOTRON)\n151\nEA\nFIRE EXTINGUISHER (6L WET CHEMICAL)\n2\nEA\nFIRE EXTINGUISHER (20LB ABC)\n8\nEA\nFIRE EXTINGUISHER (5LB CO2)\n1\nEA\nANSUL R-102 KITCHEN HOOD SUPPRESSION SYSTEMS. (INCLUDES SHUNT-TRIP ACTIVATION TEST.)\n        1. BUILDING 1 - ROOM 1-2230 DIETETICS NORTH HOOD\n        3. BUILDING 1 - ROOM 1-1324 CANTEEN\n        4. BUILDING 22   ROOM 22-1425 DIETETICS KITCHEN\n10\nEA\nANNUAL REVIEW OF AS-BUILT DRAWINGS: (AUTOCAD 2020 VERSION OR NEWER)\n1\nJB\nSEMI-ANNUAL REVIEW OF AS-BUILT DRAWINGS: (AUTOCAD 2020 VERSION OR NEWER) \n1\nJB\n\nTest Result Reporting/Recording:\nRecord test results using on-line inspection report, using http://www.buildingreports.com.\nTest results must be completed within ten (10) business days of inspection/tests.\nAny deficiencies must be noted, and System component tagged (using VA approved/supplied tags).\nA written report of deficiencies must be provided in a daily report, submitted to the Service POC/COR, for VA Safety Manager to log and track remediation of all deficiencies. Daily deficiency reports must include component, nature of deficiency and location.\nFinalize Inspection Report, using http://www.buildingreports.com. \nA monthly meeting shall be held with Contractor Inspection Team Leader, Project Manager, VA Safety Manager and Service POC/COR to review Inspection Report.\nRemediation plan for all deficiencies shall be developed, and contractor shall submit repair schedule to the Service POC/COR within five (5) business days. Contractor shall provide a quote for repair of any deficiency of an item on the exclusion list.\nContractor shall submit report to the Service POC/COR and SVA Safety Manager within five (5) business days of repair completion showing status of all identified deficiencies.\n\nDeliverables:\nDocumentation: All documentation requirements will be kept current and up-to date. Documented results are due to the Service POC/COR within five (5) business days after each (inspection, testing and maintenance) cycle. No hand-written reports will be accepted.\nContractor shall provide a secure, internet-based data-center with drop down filterable menus for all ITM and repair activities. Contractor shall allow government employees access to the Contractor s internet-based data-center. The filters shall be able to separate by individual device, group of devices, buildings, dates, EC/EP # per JCAHO, etc. The filters shall include the following information for JCAHO and higher headquarters review: \nName of the activity \nDate of the activity \nRequired frequency of the activity \nName and contact information, including affiliation, of individual who performed the activity \nResult of the activity\nContractor will provide a total of two (2) e-copies of all data by means of CD/DVD quarterly for all inspection, testing, maintenance, and repair activities for each individual device covered under this contract. E-folders shall match binder tabs exactly with all matching documents individually delineated for ease of identification. E-copy folders should replicate hard copy binder.\nContractor will provide two (2) 3-ring binders per quarter which clearly document all JCAHO and NFPA requirements for all ITM and repair activities for each individual device covered under this contract. An index shall be included in the front of the binder delineating all tabbed items.\nData Organization: Each quarterly binder (and associated internet-based data-center and CD/DVD) shall be clearly tabbed out as follows:\nBinder 1: \nTabs shall have all JCAHO-required documentation requirements only: Sample mandatory documentation requirements for JCAHO are EC.01.02.05, EPs 1-5, 9, and 19. Note, these requirements could change, and it is up to the Contractor to ensure documentation contains the most current requirements per JCAHO. \nIf an EC/EP Component contains documentation requirement for more than one (1) device, sub tabs will be created so that each separately-grouped device under a single EC/EP identifier has its own unique section. Example: EC.02.03.05, EP9.\nEach tab shall have a cover sheet specifically delineating JCAHO (EC/EP identifier) and NFPA requirements verbatim out of the most current standard or edition. 6.4.1.4 Each tab shall have a second cover sheet defining time/testing interval requirements for the specific tabbed item per NFPA and JCAHO individually.\nBinder 2:\nAll other Fire Suppression testing requirements will be contained within a secondary binder. \nThe binder will match Binder 1 in regard to organization and set-up.\nIf a device fails, the Contractor will initiate a Deficiency Notification (DN) via electronic correspondence to Service POC/COR identifying device (description/UID), location, date, and discovered fault.\nThe same DN will remain open/un-resolved until repairs are concluded. The comments on a DN will identify all repair activities, UID s of any equipment removed and new UID s of any new equipment added to the system. Ultimately the DN must contain the test results after each repair is completed\n\nAs-Built CAD Drawings:\nReview and update As-Built CAD Drawings to show all Alarm System Panels, Components, Sensors, and Wiring.\nVerify As-Built drawings are accurate. Semi-Annual & Annual review by contractor to ensure accuracy.\nCurrent As-Built drawings will be provided by VA after contract award. Drawings shall also show the Barcode ID and Fire Alarm panel address (for example: 001-01-05-123). Coordinate with VA Fire Alarm Contractor. Contractor shall review and redline As-Built AutoCAD drawing layers to show location and identify the following components:\nTamper Switches/Control Valves\nFlow Switches\nAnsul R-102 Kitchen Hood Suppression System. Include electrical shunt trips\nFire Extinguisher locations with barcode ID#\nAir Compressors\nPressure switches\nFM-200 systems\nStandpipes\nRisers\nFDC s\nHose Connections\nAlarm Valves\nDrains\nMain Drains\nSprinkler Head Boxes with quantity and type of spares\nPIV s\nAny functional fire suppression or alarm component not shown on existing drawings. This is requested so that VA shall will have comprehensive Fire Suppression System Plans.\nSix (6) months prior to contract expiration, vendor shall provide current As-Built drawings fully updated with all fire alarm system components, provided in AutoCAD and hard copies ARCH C 18  x 24 .\n\nQuality Assurance:\nContractor shall have NICET qualified staff.\nTesting Procedures shall be performed in accordance with NFPA 25, 72 & 105, or more frequently, in accordance with of Authority Having Jurisdiction. The NFPA 72 shows testing frequencies.\nWet Sprinkler System Inspection Summary - Inspect general items such as:\nAre all systems in service?\nVisualize location of heads in relationship to the distance of walls, ceilings & objects. Does the building appear to be properly heated in all areas?\nDo all exterior openings appear to be protected against freezing?\nInspect control valves:\nAre all valves in the appropriate open or closed position?\nMake sure all shut off valves are chained, locked & tamper proof. Exercise all O, S, & Y valves.\nWater supplies: Do a full flow of water test of the main drain at the sprinkler riser.\nInspect Fire Department Connections:\nConfirm that fire department connections are in satisfactory condition\nConfirm that the connection is couplings free, caps in place & check valves tight.\nConfirm that the connection is accessible and visible.\nAlarms:\nTest water motor and gong.\nTest electric alarm.\nTest supervisory alarm service.\nSprinklers:\nVerify that all sprinklers are free from corrosion, loading, or obstruction to spray discharge.\nCheck that sprinklers are less than 50 years old - thus not requiring sample testing.\nVerify that there is a stock of spare sprinklers available.\nCheck that the exterior condition of the sprinkler system is in good condition and working order.\nVerify that all sprinklers are of proper temperature ratings for their locations.\nReplace gauges as needed. All gauges must be calibrated or replaced every five (5) years.\nInspect tamper and flow switches. Note sprinkler valve size, static pressure, and residual pressure for report.\nAll activities (maintenance, testing and inspection) shall be noted in written Service Report to Service POC/COR. Final periodic Inspection/Tests shall be reported electronically, using http://www.buildingreports.com.\n\nInvoices: Each invoice shall document the service(s) completed. The Service POC/COR will review and provide a stamped Progress Report combined with Contractor s invoice to be electronically uploaded. \n\nDAYS & HOURS OF OPERATION\nNormal business hours are Monday through Friday, from 8:00 am to 4:30 pm, excluding any federal holiday.\nFederal holidays, including any days specifically declared by the President of the United States to be a national holiday, can be found at: https://www.opm.gov/policy-data-oversight/pay-leave/federal-holidays/.\nWork under this contract must be performed during normal business hours.","text":"This is a Sources Sought Notice for Fire Suppression System Maintenance, Repair, Testing & Inspection services as identified in the Statement of Work (SOW) for the Saginaw VA Medical Center in Saginaw, Michigan. The contractor shall furnish all necessary tools, parts, labor, supplies, materials, equipment, supervision and transportation necessary to furnish the services noted below.\n\nA DRAFT SOW is attached to this notice and is subject to change should a solicitation be issued as a result of this notice.\n\nPlease respond if you have the ability and actual intention to complete this requirement. All of the following information is required in your response:\n\nDUNS NUMBER\nSAM UEI NUMBER\nGSA Contract Number\nCapabilities Statement\nConfirmation of actual intent to submit an offer should an RFQ be posted in future\nCompany name and address\nPoint of contact information (name, phone, email)\nSocioeconomic size status (example: large business, small business, WOSB, SDVOSB, etc.)\n\nThis Sources Sought Notice is intended to locate any business capable of performance.\n\nThe anticipated NAICS Code for this requirement is 238220.\n\nThis is not a Request for Quotation and quotes shall not be reviewed at this time.\n\nThe Government shall not be responsible for any costs incurred by the contractor because of this Sources Sought Notice.\n\nThis notice shall not be construed as a commitment by the Government to ultimately award a contract, nor does it restrict the Government to any particular acquisition approach. All information submitted in response to this announcement is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government.\n\nResponses shall be submitted to Jeanne Ortiz at jeanne.ortiz@va.gov by Wednesday, September 10, 2025, at 10:00 AM Eastern Time (ET). Responses MUST include 36C25025Q0899 in the subject line. PHONE CALLS SHALL NOT BE ACCEPTED FOR THIS NOTICE.\n\nDRAFT STATEMENT OF WORK\n\nGENERAL\nContractor shall provide all necessary labor, materials, and expertise to perform quarterly, semi-annual (every six months) and annual maintenance, testing, inspection and repair services on the Fire Suppression Systems located at the Saginaw VA (SVA) Medical Center, 1500 Weiss Street, Saginaw, MI 48602.\n\nCONFORMANCE STANDARDS\nContractor shall perform inspections in accordance with the most current editions of (OEM)\nmaintenance manuals, most recently published versions of the following NFPA codes,\nNFPA 01, Fire Code\nNFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems\nNFPA 72, National Fire Alarm and Signaling Code\nNFPA 75, Standard for the Fire Protection of Information Technology Equipment\nNFPA 80, Standard for Fire Doors and Other Opening Protectives\nNFPA 92, Standard for Smoke Control Systems\nNFPA 105, Standard for Smoke Door Assemblies and Other Opening Protectives\nNFPA 2001, Standard on Clean Agent Fire Extinguishing Systems,\nand additional regulatory requirements as prescribed by the Joint Commission on the Accreditation of Healthcare Organizations (JCAHO).\n\nSCOPE OF WORK\nContractor shall develop a written testing plan to include ALL system components, showing the periodic frequency of inspections/testing and upcoming inspection/testing dates for the contract year for 100% of all fire alarm system devices.\n\nContractor shall provide the Service POC/COR with the completed testing plan ten (10) business days after contract is awarded, with a schedule of tentative testing dates for all components for the contract year.\n\nContractor shall complete a SAFE WORK permit provided by the facility. This permit shall be signed by the Service POC/COR or an authorized individual from Engineering Service. The permit shall be posted in Engineering and at the fire alarm panel. The permit authorizes the Contractor to remove the fire alarm system from service for testing and repair purposes. If an actual event presents during testing, Contractor is responsible for notifying Service POC/COR or an authorized individual from Engineering Service.\n\nContractor shall participate in an online monthly meeting to discuss completed inspections, inspection reports, future inspections, payment status, contractor compliance with the contract and facility compliance. Contractor shall provide a monthly agenda and provide thorough meeting minutes within seven (7) business days of the meeting.\n\nContractor is responsible for scheduling and completing all inspections, testing and planned maintenance to meet current NFPA and JCAHO standards within standard hours of operation.\n\nContractor shall notify Service POC/COR by phone and email, at least one month prior to conducting inspections and/or planned maintenance.\n\nServices shall also include the following:\nSystematic examination of all system components.\nContractor shall perform testing, cleaning, adjusting of all components as necessary to keep the system in reliable condition and proper working order.\nContractor shall furnish all tools, and cleaning materials, and parts required to perform inspections and testing.\nEmergency Service: Contractor shall respond within six (6) hours upon notification of system trouble.\nInstallation of two (2) tamper switches on Building 9 Backflow preventer in the base year only.\n\nContractor shall contact Service POC/COR by phone, prior to, and upon completion of, work. Contractor shall provide work ticket/report. Work ticket shall include complete description of the work performed and parts replaced. Contractor staff shall review inspection reports with the Service POC/COR at the end of each day and confirm all devices have been tested.\n\nThe following is a list of systems and components that shall be maintained and tested to include, but not limited to, the following:\nInitiating devices to include:\nFire Hydrants\nFire department Connections\nHose Connections\nMain drains\nDrains\nFire Sprinkler Water Flow Switches\nFire sprinkler valve supervisory switches\nAir Compressors\nFire sprinkler hi/low air supervisory switches\nPIV s\nGauges\nControls Valves\nCheck valves\nStandpipes\nAuxiliary devices, to include flow switch bells\n\nEXCLUSIONARY ITEMS: Fire hydrants, air compressors, & fire extinguisher replacements. Contractor to provide a quote. These will be processed under a separate purchase order.\n\nContractor shall submit a quarterly report to Service POC/COR to include, but not limited to, the following information: (This is in addition to uploading reports into Building Reports )\nTesting Schedule:\nBuilding number.\nSystem type tested.\nWhat was tested.\nDetailed report:\nBuilding number.\nLocation of device.\nType of Device.\nTest Results original and current.\nZone (Zone FACP).\nCode (Chime Code).\nQuarter.\n6 months.\nYear.\nDate.\nComments.\nFire Alarm Discrepancy Report:\nBuilding Number.\nDevice and location.\nType of Discrepancy.\n\nThese publications shall be adhered to when conducting repairs, testing, maintenance and inspections:\nManufacturer s maintenance manuals.\nManufacturer s recommendations.\nNational Fire Protection Association Standards. (NFPA 25, 72 & 105)\nNational Electrical Code (NEC).\nNational Fire Code.\nJCAHO Requirements. (VA will provide. Contact Service POC/COR).\n\nFire Sprinkler and Suppression System Components (An initial inventory during first annual fire alarm inspection and test shall be conducted by contractor to confirm existing numbers.)\nFire Sprinkler and Suppression Systems include the following components:\nITEM\nQTY\nUNIT\nWATER FLOWS\n61\nEA\nSPRINKLER TAMPER SWITCHES\n78\nEA\nCONTROL VALVE\n81\nEA\nSPRINKLER RISER (WET)\n9\nEA\nSPRINKLER RISER (DRY)\n3\nEA\nFIRE HYDRANTS\n10\nEA\nFIRE DEPARTMENT CONNECTIONS (FDC S)\n9\nEA\nHOSE CONNECTIONS\n46\nEA\nSTANDPIPE\n7\nEA\nSPRINKLER HEAD BOXES (SPARES)\n10\nEA\nSPRINKLER HEAD SPARES\n40\nEA\nCHECK VALVE\n19\nEA\nGAUGES\n\nDRAINS\n59\nEA\nPIV\n39\nEA\nMAIN DRAIN (INTO BUILDINGS)\n6\nEA\nFIRE EXTINGUISHER (2.5 LB ABC)\n9\nEA\nFIRE EXTINGUISHER (5 LB ABC)\n1\nEA\nFIRE EXTINGUISHER (10 LB ABC)\n64\nEA\nFIRE EXTINGUISHER (10 HALOTRON)\n151\nEA\nFIRE EXTINGUISHER (6L WET CHEMICAL)\n2\nEA\nFIRE EXTINGUISHER (20LB ABC)\n8\nEA\nFIRE EXTINGUISHER (5LB CO2)\n1\nEA\nANSUL R-102 KITCHEN HOOD SUPPRESSION SYSTEMS. (INCLUDES SHUNT-TRIP ACTIVATION TEST.)\n1. BUILDING 1 - ROOM 1-2230 DIETETICS NORTH HOOD\n3. BUILDING 1 - ROOM 1-1324 CANTEEN\n4. BUILDING 22 ROOM 22-1425 DIETETICS KITCHEN\n10\nEA\nANNUAL REVIEW OF AS-BUILT DRAWINGS: (AUTOCAD 2020 VERSION OR NEWER)\n1\nJB\nSEMI-ANNUAL REVIEW OF AS-BUILT DRAWINGS: (AUTOCAD 2020 VERSION OR NEWER)\n1\nJB\n\nTest Result Reporting/Recording:\nRecord test results using on-line inspection report, using http://www.buildingreports.com.\nTest results must be completed within ten (10) business days of inspection/tests.\nAny deficiencies must be noted, and System component tagged (using VA approved/supplied tags).\nA written report of deficiencies must be provided in a daily report, submitted to the Service POC/COR, for VA Safety Manager to log and track remediation of all deficiencies. Daily deficiency reports must include component, nature of deficiency and location.\nFinalize Inspection Report, using http://www.buildingreports.com.\nA monthly meeting shall be held with Contractor Inspection Team Leader, Project Manager, VA Safety Manager and Service POC/COR to review Inspection Report.\nRemediation plan for all deficiencies shall be developed, and contractor shall submit repair schedule to the Service POC/COR within five (5) business days. Contractor shall provide a quote for repair of any deficiency of an item on the exclusion list.\nContractor shall submit report to the Service POC/COR and SVA Safety Manager within five (5) business days of repair completion showing status of all identified deficiencies.\n\nDeliverables:\nDocumentation: All documentation requirements will be kept current and up-to date. Documented results are due to the Service POC/COR within five (5) business days after each (inspection, testing and maintenance) cycle. No hand-written reports will be accepted.\nContractor shall provide a secure, internet-based data-center with drop down filterable menus for all ITM and repair activities. Contractor shall allow government employees access to the Contractor s internet-based data-center. The filters shall be able to separate by individual device, group of devices, buildings, dates, EC/EP # per JCAHO, etc. The filters shall include the following information for JCAHO and higher headquarters review:\nName of the activity\nDate of the activity\nRequired frequency of the activity\nName and contact information, including affiliation, of individual who performed the activity\nResult of the activity\nContractor will provide a total of two (2) e-copies of all data by means of CD/DVD quarterly for all inspection, testing, maintenance, and repair activities for each individual device covered under this contract. E-folders shall match binder tabs exactly with all matching documents individually delineated for ease of identification. E-copy folders should replicate hard copy binder.\nContractor will provide two (2) 3-ring binders per quarter which clearly document all JCAHO and NFPA requirements for all ITM and repair activities for each individual device covered under this contract. An index shall be included in the front of the binder delineating all tabbed items.\nData Organization: Each quarterly binder (and associated internet-based data-center and CD/DVD) shall be clearly tabbed out as follows:\nBinder 1:\nTabs shall have all JCAHO-required documentation requirements only: Sample mandatory documentation requirements for JCAHO are EC.01.02.05, EPs 1-5, 9, and 19. Note, these requirements could change, and it is up to the Contractor to ensure documentation contains the most current requirements per JCAHO.\nIf an EC/EP Component contains documentation requirement for more than one (1) device, sub tabs will be created so that each separately-grouped device under a single EC/EP identifier has its own unique section. Example: EC.02.03.05, EP9.\nEach tab shall have a cover sheet specifically delineating JCAHO (EC/EP identifier) and NFPA requirements verbatim out of the most current standard or edition. 6.4.1.4 Each tab shall have a second cover sheet defining time/testing interval requirements for the specific tabbed item per NFPA and JCAHO individually.\nBinder 2:\nAll other Fire Suppression testing requirements will be contained within a secondary binder.\nThe binder will match Binder 1 in regard to organization and set-up.\nIf a device fails, the Contractor will initiate a Deficiency Notification (DN) via electronic correspondence to Service POC/COR identifying device (description/UID), location, date, and discovered fault.\nThe same DN will remain open/un-resolved until repairs are concluded. The comments on a DN will identify all repair activities, UID s of any equipment removed and new UID s of any new equipment added to the system. Ultimately the DN must contain the test results after each repair is completed\n\nAs-Built CAD Drawings:\nReview and update As-Built CAD Drawings to show all Alarm System Panels, Components, Sensors, and Wiring.\nVerify As-Built drawings are accurate. Semi-Annual & Annual review by contractor to ensure accuracy.\nCurrent As-Built drawings will be provided by VA after contract award. Drawings shall also show the Barcode ID and Fire Alarm panel address (for example: 001-01-05-123). Coordinate with VA Fire Alarm Contractor. Contractor shall review and redline As-Built AutoCAD drawing layers to show location and identify the following components:\nTamper Switches/Control Valves\nFlow Switches\nAnsul R-102 Kitchen Hood Suppression System. Include electrical shunt trips\nFire Extinguisher locations with barcode ID#\nAir Compressors\nPressure switches\nFM-200 systems\nStandpipes\nRisers\nFDC s\nHose Connections\nAlarm Valves\nDrains\nMain Drains\nSprinkler Head Boxes with quantity and type of spares\nPIV s\nAny functional fire suppression or alarm component not shown on existing drawings. This is requested so that VA shall will have comprehensive Fire Suppression System Plans.\nSix (6) months prior to contract expiration, vendor shall provide current As-Built drawings fully updated with all fire alarm system components, provided in AutoCAD and hard copies ARCH C 18 x 24 .\n\nQuality Assurance:\nContractor shall have NICET qualified staff.\nTesting Procedures shall be performed in accordance with NFPA 25, 72 & 105, or more frequently, in accordance with of Authority Having Jurisdiction. The NFPA 72 shows testing frequencies.\nWet Sprinkler System Inspection Summary - Inspect general items such as:\nAre all systems in service?\nVisualize location of heads in relationship to the distance of walls, ceilings & objects. Does the building appear to be properly heated in all areas?\nDo all exterior openings appear to be protected against freezing?\nInspect control valves:\nAre all valves in the appropriate open or closed position?\nMake sure all shut off valves are chained, locked & tamper proof. Exercise all O, S, & Y valves.\nWater supplies: Do a full flow of water test of the main drain at the sprinkler riser.\nInspect Fire Department Connections:\nConfirm that fire department connections are in satisfactory condition\nConfirm that the connection is couplings free, caps in place & check valves tight.\nConfirm that the connection is accessible and visible.\nAlarms:\nTest water motor and gong.\nTest electric alarm.\nTest supervisory alarm service.\nSprinklers:\nVerify that all sprinklers are free from corrosion, loading, or obstruction to spray discharge.\nCheck that sprinklers are less than 50 years old - thus not requiring sample testing.\nVerify that there is a stock of spare sprinklers available.\nCheck that the exterior condition of the sprinkler system is in good condition and working order.\nVerify that all sprinklers are of proper temperature ratings for their locations.\nReplace gauges as needed. All gauges must be calibrated or replaced every five (5) years.\nInspect tamper and flow switches. Note sprinkler valve size, static pressure, and residual pressure for report.\nAll activities (maintenance, testing and inspection) shall be noted in written Service Report to Service POC/COR. Final periodic Inspection/Tests shall be reported electronically, using http://www.buildingreports.com.\n\nInvoices: Each invoice shall document the service(s) completed. The Service POC/COR will review and provide a stamped Progress Report combined with Contractor s invoice to be electronically uploaded.\n\nDAYS & HOURS OF OPERATION\nNormal business hours are Monday through Friday, from 8:00 am to 4:30 pm, excluding any federal holiday.\nFederal holidays, including any days specifically declared by the President of the United States to be a national holiday, can be found at: https://www.opm.gov/policy-data-oversight/pay-leave/federal-holidays/.\nWork under this contract must be performed during normal business hours.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25025Q0899","place_of_performance":{"zip":"48602","city":{"name":"REGARD TO THIS SOURCES SOUGHT NOTICE"},"street":"Saginaw VA Medical Center 1500 Weiss Street","country":{"code":"USA","name":"UNITED STATES"},"street2":"Saginaw, MI 48602 VENDORS - DO NOT CONTACT THE FACILITY IN"},"product_service_code":"J042"}],"due_at":"2025-09-10T14:00:00Z","due_date":"2025-09-10","closes_at":"2025-09-10T14:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","state":"MI","county":"26145","county_name":"Saginaw County","city":null,"city_name":null,"country":"USA","state_source":"sam_zip","state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-01T04:57:46.075431Z","principal_notice_id":"8c3149dacfd740bb9b6ad4fa0b64bddc","description":{"text":"This is a Sources Sought Notice for Fire Suppression System Maintenance, Repair, Testing & Inspection services as identified in the Statement of Work (SOW) for the Saginaw VA Medical Center in Saginaw, Michigan. The contractor shall furnish all necessary tools, parts, labor, supplies, materials, equipment, supervision and transportation necessary to furnish the services noted below.\n\nA DRAFT SOW is attached to this notice and is subject to change should a solicitation be issued as a result of this notice.\n\nPlease respond if you have the ability and actual intention to complete this requirement. All of the following information is required in your response:\n\nDUNS NUMBER\nSAM UEI NUMBER\nGSA Contract Number\nCapabilities Statement\nConfirmation of actual intent to submit an offer should an RFQ be posted in future\nCompany name and address\nPoint of contact information (name, phone, email)\nSocioeconomic size status (example: large business, small business, WOSB, SDVOSB, etc.)\n\nThis Sources Sought Notice is intended to locate any business capable of performance.\n\nThe anticipated NAICS Code for this requirement is 238220.\n\nThis is not a Request for Quotation and quotes shall not be reviewed at this time.\n\nThe Government shall not be responsible for any costs incurred by the contractor because of this Sources Sought Notice.\n\nThis notice shall not be construed as a commitment by the Government to ultimately award a contract, nor does it restrict the Government to any particular acquisition approach. All information submitted in response to this announcement is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government.\n\nResponses shall be submitted to Jeanne Ortiz at jeanne.ortiz@va.gov by Wednesday, September 10, 2025, at 10:00 AM Eastern Time (ET). Responses MUST include 36C25025Q0899 in the subject line. PHONE CALLS SHALL NOT BE ACCEPTED FOR THIS NOTICE.\n\nDRAFT STATEMENT OF WORK\n\nGENERAL\nContractor shall provide all necessary labor, materials, and expertise to perform quarterly, semi-annual (every six months) and annual maintenance, testing, inspection and repair services on the Fire Suppression Systems located at the Saginaw VA (SVA) Medical Center, 1500 Weiss Street, Saginaw, MI 48602.\n\nCONFORMANCE STANDARDS\nContractor shall perform inspections in accordance with the most current editions of (OEM)\nmaintenance manuals, most recently published versions of the following NFPA codes,\nNFPA 01, Fire Code\nNFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems\nNFPA 72, National Fire Alarm and Signaling Code\nNFPA 75, Standard for the Fire Protection of Information Technology Equipment\nNFPA 80, Standard for Fire Doors and Other Opening Protectives\nNFPA 92, Standard for Smoke Control Systems\nNFPA 105, Standard for Smoke Door Assemblies and Other Opening Protectives\nNFPA 2001, Standard on Clean Agent Fire Extinguishing Systems,\nand additional regulatory requirements as prescribed by the Joint Commission on the Accreditation of Healthcare Organizations (JCAHO).\n\nSCOPE OF WORK\nContractor shall develop a written testing plan to include ALL system components, showing the periodic frequency of inspections/testing and upcoming inspection/testing dates for the contract year for 100% of all fire alarm system devices.\n\nContractor shall provide the Service POC/COR with the completed testing plan ten (10) business days after contract is awarded, with a schedule of tentative testing dates for all components for the contract year.\n\nContractor shall complete a SAFE WORK permit provided by the facility. This permit shall be signed by the Service POC/COR or an authorized individual from Engineering Service. The permit shall be posted in Engineering and at the fire alarm panel. The permit authorizes the Contractor to remove the fire alarm system from service for testing and repair purposes. If an actual event presents during testing, Contractor is responsible for notifying Service POC/COR or an authorized individual from Engineering Service.\n\nContractor shall participate in an online monthly meeting to discuss completed inspections, inspection reports, future inspections, payment status, contractor compliance with the contract and facility compliance. Contractor shall provide a monthly agenda and provide thorough meeting minutes within seven (7) business days of the meeting.\n\nContractor is responsible for scheduling and completing all inspections, testing and planned maintenance to meet current NFPA and JCAHO standards within standard hours of operation.\n\nContractor shall notify Service POC/COR by phone and email, at least one month prior to conducting inspections and/or planned maintenance.\n\nServices shall also include the following:\nSystematic examination of all system components.\nContractor shall perform testing, cleaning, adjusting of all components as necessary to keep the system in reliable condition and proper working order.\nContractor shall furnish all tools, and cleaning materials, and parts required to perform inspections and testing.\nEmergency Service: Contractor shall respond within six (6) hours upon notification of system trouble.\nInstallation of two (2) tamper switches on Building 9 Backflow preventer in the base year only.\n\nContractor shall contact Service POC/COR by phone, prior to, and upon completion of, work. Contractor shall provide work ticket/report. Work ticket shall include complete description of the work performed and parts replaced. Contractor staff shall review inspection reports with the Service POC/COR at the end of each day and confirm all devices have been tested.\n\nThe following is a list of systems and components that shall be maintained and tested to include, but not limited to, the following:\nInitiating devices to include:\nFire Hydrants\nFire department Connections\nHose Connections\nMain drains\nDrains\nFire Sprinkler Water Flow Switches\nFire sprinkler valve supervisory switches\nAir Compressors\nFire sprinkler hi/low air supervisory switches\nPIV s\nGauges\nControls Valves\nCheck valves\nStandpipes\nAuxiliary devices, to include flow switch bells\n\nEXCLUSIONARY ITEMS: Fire hydrants, air compressors, & fire extinguisher replacements. Contractor to provide a quote. These will be processed under a separate purchase order.\n\nContractor shall submit a quarterly report to Service POC/COR to include, but not limited to, the following information: (This is in addition to uploading reports into Building Reports )\nTesting Schedule:\nBuilding number.\nSystem type tested.\nWhat was tested.\nDetailed report:\nBuilding number.\nLocation of device.\nType of Device.\nTest Results original and current.\nZone (Zone FACP).\nCode (Chime Code).\nQuarter.\n6 months.\nYear.\nDate.\nComments.\nFire Alarm Discrepancy Report:\nBuilding Number.\nDevice and location.\nType of Discrepancy.\n\nThese publications shall be adhered to when conducting repairs, testing, maintenance and inspections:\nManufacturer s maintenance manuals.\nManufacturer s recommendations.\nNational Fire Protection Association Standards. (NFPA 25, 72 & 105)\nNational Electrical Code (NEC).\nNational Fire Code.\nJCAHO Requirements. (VA will provide. Contact Service POC/COR).\n\nFire Sprinkler and Suppression System Components (An initial inventory during first annual fire alarm inspection and test shall be conducted by contractor to confirm existing numbers.)\nFire Sprinkler and Suppression Systems include the following components:\nITEM\nQTY\nUNIT\nWATER FLOWS\n61\nEA\nSPRINKLER TAMPER SWITCHES\n78\nEA\nCONTROL VALVE\n81\nEA\nSPRINKLER RISER (WET)\n9\nEA\nSPRINKLER RISER (DRY)\n3\nEA\nFIRE HYDRANTS\n10\nEA\nFIRE DEPARTMENT CONNECTIONS (FDC S)\n9\nEA\nHOSE CONNECTIONS\n46\nEA\nSTANDPIPE\n7\nEA\nSPRINKLER HEAD BOXES (SPARES)\n10\nEA\nSPRINKLER HEAD SPARES\n40\nEA\nCHECK VALVE\n19\nEA\nGAUGES\n\nDRAINS\n59\nEA\nPIV\n39\nEA\nMAIN DRAIN (INTO BUILDINGS)\n6\nEA\nFIRE EXTINGUISHER (2.5 LB ABC)\n9\nEA\nFIRE EXTINGUISHER (5 LB ABC)\n1\nEA\nFIRE EXTINGUISHER (10 LB ABC)\n64\nEA\nFIRE EXTINGUISHER (10 HALOTRON)\n151\nEA\nFIRE EXTINGUISHER (6L WET CHEMICAL)\n2\nEA\nFIRE EXTINGUISHER (20LB ABC)\n8\nEA\nFIRE EXTINGUISHER (5LB CO2)\n1\nEA\nANSUL R-102 KITCHEN HOOD SUPPRESSION SYSTEMS. (INCLUDES SHUNT-TRIP ACTIVATION TEST.)\n1. BUILDING 1 - ROOM 1-2230 DIETETICS NORTH HOOD\n3. BUILDING 1 - ROOM 1-1324 CANTEEN\n4. BUILDING 22 ROOM 22-1425 DIETETICS KITCHEN\n10\nEA\nANNUAL REVIEW OF AS-BUILT DRAWINGS: (AUTOCAD 2020 VERSION OR NEWER)\n1\nJB\nSEMI-ANNUAL REVIEW OF AS-BUILT DRAWINGS: (AUTOCAD 2020 VERSION OR NEWER)\n1\nJB\n\nTest Result Reporting/Recording:\nRecord test results using on-line inspection report, using http://www.buildingreports.com.\nTest results must be completed within ten (10) business days of inspection/tests.\nAny deficiencies must be noted, and System component tagged (using VA approved/supplied tags).\nA written report of deficiencies must be provided in a daily report, submitted to the Service POC/COR, for VA Safety Manager to log and track remediation of all deficiencies. Daily deficiency reports must include component, nature of deficiency and location.\nFinalize Inspection Report, using http://www.buildingreports.com.\nA monthly meeting shall be held with Contractor Inspection Team Leader, Project Manager, VA Safety Manager and Service POC/COR to review Inspection Report.\nRemediation plan for all deficiencies shall be developed, and contractor shall submit repair schedule to the Service POC/COR within five (5) business days. Contractor shall provide a quote for repair of any deficiency of an item on the exclusion list.\nContractor shall submit report to the Service POC/COR and SVA Safety Manager within five (5) business days of repair completion showing status of all identified deficiencies.\n\nDeliverables:\nDocumentation: All documentation requirements will be kept current and up-to date. Documented results are due to the Service POC/COR within five (5) business days after each (inspection, testing and maintenance) cycle. No hand-written reports will be accepted.\nContractor shall provide a secure, internet-based data-center with drop down filterable menus for all ITM and repair activities. Contractor shall allow government employees access to the Contractor s internet-based data-center. The filters shall be able to separate by individual device, group of devices, buildings, dates, EC/EP # per JCAHO, etc. The filters shall include the following information for JCAHO and higher headquarters review:\nName of the activity\nDate of the activity\nRequired frequency of the activity\nName and contact information, including affiliation, of individual who performed the activity\nResult of the activity\nContractor will provide a total of two (2) e-copies of all data by means of CD/DVD quarterly for all inspection, testing, maintenance, and repair activities for each individual device covered under this contract. E-folders shall match binder tabs exactly with all matching documents individually delineated for ease of identification. E-copy folders should replicate hard copy binder.\nContractor will provide two (2) 3-ring binders per quarter which clearly document all JCAHO and NFPA requirements for all ITM and repair activities for each individual device covered under this contract. An index shall be included in the front of the binder delineating all tabbed items.\nData Organization: Each quarterly binder (and associated internet-based data-center and CD/DVD) shall be clearly tabbed out as follows:\nBinder 1:\nTabs shall have all JCAHO-required documentation requirements only: Sample mandatory documentation requirements for JCAHO are EC.01.02.05, EPs 1-5, 9, and 19. Note, these requirements could change, and it is up to the Contractor to ensure documentation contains the most current requirements per JCAHO.\nIf an EC/EP Component contains documentation requirement for more than one (1) device, sub tabs will be created so that each separately-grouped device under a single EC/EP identifier has its own unique section. Example: EC.02.03.05, EP9.\nEach tab shall have a cover sheet specifically delineating JCAHO (EC/EP identifier) and NFPA requirements verbatim out of the most current standard or edition. 6.4.1.4 Each tab shall have a second cover sheet defining time/testing interval requirements for the specific tabbed item per NFPA and JCAHO individually.\nBinder 2:\nAll other Fire Suppression testing requirements will be contained within a secondary binder.\nThe binder will match Binder 1 in regard to organization and set-up.\nIf a device fails, the Contractor will initiate a Deficiency Notification (DN) via electronic correspondence to Service POC/COR identifying device (description/UID), location, date, and discovered fault.\nThe same DN will remain open/un-resolved until repairs are concluded. The comments on a DN will identify all repair activities, UID s of any equipment removed and new UID s of any new equipment added to the system. Ultimately the DN must contain the test results after each repair is completed\n\nAs-Built CAD Drawings:\nReview and update As-Built CAD Drawings to show all Alarm System Panels, Components, Sensors, and Wiring.\nVerify As-Built drawings are accurate. Semi-Annual & Annual review by contractor to ensure accuracy.\nCurrent As-Built drawings will be provided by VA after contract award. Drawings shall also show the Barcode ID and Fire Alarm panel address (for example: 001-01-05-123). Coordinate with VA Fire Alarm Contractor. Contractor shall review and redline As-Built AutoCAD drawing layers to show location and identify the following components:\nTamper Switches/Control Valves\nFlow Switches\nAnsul R-102 Kitchen Hood Suppression System. Include electrical shunt trips\nFire Extinguisher locations with barcode ID#\nAir Compressors\nPressure switches\nFM-200 systems\nStandpipes\nRisers\nFDC s\nHose Connections\nAlarm Valves\nDrains\nMain Drains\nSprinkler Head Boxes with quantity and type of spares\nPIV s\nAny functional fire suppression or alarm component not shown on existing drawings. This is requested so that VA shall will have comprehensive Fire Suppression System Plans.\nSix (6) months prior to contract expiration, vendor shall provide current As-Built drawings fully updated with all fire alarm system components, provided in AutoCAD and hard copies ARCH C 18 x 24 .\n\nQuality Assurance:\nContractor shall have NICET qualified staff.\nTesting Procedures shall be performed in accordance with NFPA 25, 72 & 105, or more frequently, in accordance with of Authority Having Jurisdiction. The NFPA 72 shows testing frequencies.\nWet Sprinkler System Inspection Summary - Inspect general items such as:\nAre all systems in service?\nVisualize location of heads in relationship to the distance of walls, ceilings & objects. Does the building appear to be properly heated in all areas?\nDo all exterior openings appear to be protected against freezing?\nInspect control valves:\nAre all valves in the appropriate open or closed position?\nMake sure all shut off valves are chained, locked & tamper proof. Exercise all O, S, & Y valves.\nWater supplies: Do a full flow of water test of the main drain at the sprinkler riser.\nInspect Fire Department Connections:\nConfirm that fire department connections are in satisfactory condition\nConfirm that the connection is couplings free, caps in place & check valves tight.\nConfirm that the connection is accessible and visible.\nAlarms:\nTest water motor and gong.\nTest electric alarm.\nTest supervisory alarm service.\nSprinklers:\nVerify that all sprinklers are free from corrosion, loading, or obstruction to spray discharge.\nCheck that sprinklers are less than 50 years old - thus not requiring sample testing.\nVerify that there is a stock of spare sprinklers available.\nCheck that the exterior condition of the sprinkler system is in good condition and working order.\nVerify that all sprinklers are of proper temperature ratings for their locations.\nReplace gauges as needed. All gauges must be calibrated or replaced every five (5) years.\nInspect tamper and flow switches. Note sprinkler valve size, static pressure, and residual pressure for report.\nAll activities (maintenance, testing and inspection) shall be noted in written Service Report to Service POC/COR. Final periodic Inspection/Tests shall be reported electronically, using http://www.buildingreports.com.\n\nInvoices: Each invoice shall document the service(s) completed. The Service POC/COR will review and provide a stamped Progress Report combined with Contractor s invoice to be electronically uploaded.\n\nDAYS & HOURS OF OPERATION\nNormal business hours are Monday through Friday, from 8:00 am to 4:30 pm, excluding any federal holiday.\nFederal holidays, including any days specifically declared by the President of the United States to be a national holiday, can be found at: https://www.opm.gov/policy-data-oversight/pay-leave/federal-holidays/.\nWork under this contract must be performed during normal business hours.","html":"This is a Sources Sought Notice for Fire Suppression System Maintenance, Repair, Testing & Inspection services as identified in the Statement of Work (SOW) for the Saginaw VA Medical Center in Saginaw, Michigan. The contractor shall furnish all necessary tools, parts, labor, supplies, materials, equipment, supervision and transportation necessary to furnish the services noted below.\n\nA DRAFT SOW is attached to this notice and is subject to change should a solicitation be issued as a result of this notice. \n\nPlease respond if you have the ability and actual intention to complete this requirement. All of the following information is required in your response:\n\nDUNS NUMBER\nSAM UEI NUMBER\nGSA Contract Number\nCapabilities Statement\nConfirmation of actual intent to submit an offer should an RFQ be posted in future\nCompany name and address\nPoint of contact information (name, phone, email)\nSocioeconomic size status (example: large business, small business, WOSB, SDVOSB, etc.)\n\nThis Sources Sought Notice is intended to locate any business capable of performance.\n\nThe anticipated NAICS Code for this requirement is 238220.\n\nThis is not a Request for Quotation and quotes shall not be reviewed at this time.\n\nThe Government shall not be responsible for any costs incurred by the contractor because of this Sources Sought Notice.\n\nThis notice shall not be construed as a commitment by the Government to ultimately award a contract, nor does it restrict the Government to any particular acquisition approach. All information submitted in response to this announcement is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government.\n\nResponses shall be submitted to Jeanne Ortiz at jeanne.ortiz@va.gov by Wednesday, September 10, 2025, at 10:00 AM Eastern Time (ET). Responses MUST include 36C25025Q0899 in the subject line. PHONE CALLS SHALL NOT BE ACCEPTED FOR THIS NOTICE.\n\nDRAFT STATEMENT OF WORK\n\nGENERAL\nContractor shall provide all necessary labor, materials, and expertise to perform quarterly, semi-annual (every six months) and annual maintenance, testing, inspection and repair services on the Fire Suppression Systems located at the Saginaw VA (SVA) Medical Center, 1500 Weiss Street, Saginaw, MI 48602. \n\nCONFORMANCE STANDARDS\nContractor shall perform inspections in accordance with the most current editions of (OEM) \nmaintenance manuals, most recently published versions of the following NFPA codes, \nNFPA 01, Fire Code\nNFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems \nNFPA 72, National Fire Alarm and Signaling Code\nNFPA 75, Standard for the Fire Protection of Information Technology Equipment\nNFPA 80, Standard for Fire Doors and Other Opening Protectives\nNFPA 92, Standard for Smoke Control Systems\nNFPA 105, Standard for Smoke Door Assemblies and Other Opening Protectives\nNFPA 2001, Standard on Clean Agent Fire Extinguishing Systems,\nand additional regulatory requirements as prescribed by the Joint Commission on the Accreditation of Healthcare Organizations (JCAHO).\n\nSCOPE OF WORK\nContractor shall develop a written testing plan to include ALL system components, showing the periodic frequency of inspections/testing and upcoming inspection/testing dates for the contract year for 100% of all fire alarm system devices.\n\nContractor shall provide the Service POC/COR with the completed testing plan ten (10) business days after contract is awarded, with a schedule of tentative testing dates for all components for the contract year.\n\nContractor shall complete a  SAFE WORK  permit provided by the facility. This permit shall be signed by the Service POC/COR or an authorized individual from Engineering Service. The permit shall be posted in Engineering and at the fire alarm panel. The permit authorizes the Contractor to remove the fire alarm system from service for testing and repair purposes. If an actual event presents during testing, Contractor is responsible for notifying Service POC/COR or an authorized individual from Engineering Service.\n\nContractor shall participate in an online monthly meeting to discuss completed inspections, inspection reports, future inspections, payment status, contractor compliance with the contract and facility compliance. Contractor shall provide a monthly agenda and provide thorough meeting minutes within seven (7) business days of the meeting.\n\nContractor is responsible for scheduling and completing all inspections, testing and planned maintenance to meet current NFPA and JCAHO standards within standard hours of operation.\n\nContractor shall notify Service POC/COR by phone and email, at least one month prior to conducting inspections and/or planned maintenance.\n\nServices shall also include the following:\nSystematic examination of all system components.\nContractor shall perform testing, cleaning, adjusting of all components as necessary to keep the system in reliable condition and proper working order.\nContractor shall furnish all tools, and cleaning materials, and parts required to perform inspections and testing.\nEmergency Service: Contractor shall respond within six (6) hours upon notification of system trouble.\nInstallation of two (2) tamper switches on Building 9 Backflow preventer in the base year only. \n\nContractor shall contact Service POC/COR by phone, prior to, and upon completion of, work. Contractor shall provide work ticket/report. Work ticket shall include complete description of the work performed and parts replaced. Contractor staff shall review inspection reports with the Service POC/COR at the end of each day and confirm all devices have been tested.\n\nThe following is a list of systems and components that shall be maintained and tested to include, but not limited to, the following:\nInitiating devices to include:\nFire Hydrants\nFire department Connections\nHose Connections\nMain drains\nDrains\nFire Sprinkler Water Flow Switches\nFire sprinkler valve supervisory switches\nAir Compressors\nFire sprinkler hi/low air supervisory switches\nPIV s\nGauges\nControls Valves\nCheck valves\nStandpipes\nAuxiliary devices, to include flow switch bells \n\nEXCLUSIONARY ITEMS: Fire hydrants, air compressors, & fire extinguisher replacements. Contractor to provide a quote. These will be processed under a separate purchase order.\n\nContractor shall submit a quarterly report to Service POC/COR to include, but not limited to, the following information: (This is in addition to uploading reports into  Building Reports )\nTesting Schedule:\nBuilding number.\nSystem type tested.\nWhat was tested.\nDetailed report:\nBuilding number.\nLocation of device.\nType of Device.\nTest Results   original and current.\nZone (Zone FACP).\nCode (Chime Code).\nQuarter.\n6 months.\nYear.\nDate.\nComments.\nFire Alarm Discrepancy Report:\nBuilding Number.\nDevice and location.\nType of Discrepancy.\n\nThese publications shall be adhered to when conducting repairs, testing, maintenance and inspections:\nManufacturer s maintenance manuals.\nManufacturer s recommendations.\nNational Fire Protection Association Standards. (NFPA 25, 72 & 105)\nNational Electrical Code (NEC).\nNational Fire Code.\nJCAHO Requirements. (VA will provide. Contact Service POC/COR).\n\nFire Sprinkler and Suppression System Components (An initial inventory during first annual fire alarm inspection and test shall be conducted by contractor to confirm existing numbers.)\nFire Sprinkler and Suppression Systems include the following components:\nITEM\nQTY\nUNIT\nWATER FLOWS\n61\nEA\nSPRINKLER TAMPER SWITCHES\n78\nEA\nCONTROL VALVE\n81\nEA\nSPRINKLER RISER (WET) \n9\nEA\nSPRINKLER RISER (DRY)\n3\nEA\nFIRE HYDRANTS\n10\nEA\nFIRE DEPARTMENT CONNECTIONS (FDC S)\n9\nEA\nHOSE CONNECTIONS\n46\nEA\nSTANDPIPE\n7\nEA\nSPRINKLER HEAD BOXES (SPARES)\n10\nEA\nSPRINKLER HEAD SPARES\n40\nEA\nCHECK VALVE\n19\nEA\nGAUGES\n\n\nDRAINS\n59\nEA\nPIV\n39\nEA\nMAIN DRAIN (INTO BUILDINGS)\n6\nEA\nFIRE EXTINGUISHER (2.5 LB ABC)\n9\nEA\nFIRE EXTINGUISHER (5 LB ABC)\n1\nEA\nFIRE EXTINGUISHER (10 LB ABC)\n64\nEA\nFIRE EXTINGUISHER (10 HALOTRON)\n151\nEA\nFIRE EXTINGUISHER (6L WET CHEMICAL)\n2\nEA\nFIRE EXTINGUISHER (20LB ABC)\n8\nEA\nFIRE EXTINGUISHER (5LB CO2)\n1\nEA\nANSUL R-102 KITCHEN HOOD SUPPRESSION SYSTEMS. (INCLUDES SHUNT-TRIP ACTIVATION TEST.)\n        1. BUILDING 1 - ROOM 1-2230 DIETETICS NORTH HOOD\n        3. BUILDING 1 - ROOM 1-1324 CANTEEN\n        4. BUILDING 22   ROOM 22-1425 DIETETICS KITCHEN\n10\nEA\nANNUAL REVIEW OF AS-BUILT DRAWINGS: (AUTOCAD 2020 VERSION OR NEWER)\n1\nJB\nSEMI-ANNUAL REVIEW OF AS-BUILT DRAWINGS: (AUTOCAD 2020 VERSION OR NEWER) \n1\nJB\n\nTest Result Reporting/Recording:\nRecord test results using on-line inspection report, using http://www.buildingreports.com.\nTest results must be completed within ten (10) business days of inspection/tests.\nAny deficiencies must be noted, and System component tagged (using VA approved/supplied tags).\nA written report of deficiencies must be provided in a daily report, submitted to the Service POC/COR, for VA Safety Manager to log and track remediation of all deficiencies. Daily deficiency reports must include component, nature of deficiency and location.\nFinalize Inspection Report, using http://www.buildingreports.com. \nA monthly meeting shall be held with Contractor Inspection Team Leader, Project Manager, VA Safety Manager and Service POC/COR to review Inspection Report.\nRemediation plan for all deficiencies shall be developed, and contractor shall submit repair schedule to the Service POC/COR within five (5) business days. Contractor shall provide a quote for repair of any deficiency of an item on the exclusion list.\nContractor shall submit report to the Service POC/COR and SVA Safety Manager within five (5) business days of repair completion showing status of all identified deficiencies.\n\nDeliverables:\nDocumentation: All documentation requirements will be kept current and up-to date. Documented results are due to the Service POC/COR within five (5) business days after each (inspection, testing and maintenance) cycle. No hand-written reports will be accepted.\nContractor shall provide a secure, internet-based data-center with drop down filterable menus for all ITM and repair activities. Contractor shall allow government employees access to the Contractor s internet-based data-center. The filters shall be able to separate by individual device, group of devices, buildings, dates, EC/EP # per JCAHO, etc. The filters shall include the following information for JCAHO and higher headquarters review: \nName of the activity \nDate of the activity \nRequired frequency of the activity \nName and contact information, including affiliation, of individual who performed the activity \nResult of the activity\nContractor will provide a total of two (2) e-copies of all data by means of CD/DVD quarterly for all inspection, testing, maintenance, and repair activities for each individual device covered under this contract. E-folders shall match binder tabs exactly with all matching documents individually delineated for ease of identification. E-copy folders should replicate hard copy binder.\nContractor will provide two (2) 3-ring binders per quarter which clearly document all JCAHO and NFPA requirements for all ITM and repair activities for each individual device covered under this contract. An index shall be included in the front of the binder delineating all tabbed items.\nData Organization: Each quarterly binder (and associated internet-based data-center and CD/DVD) shall be clearly tabbed out as follows:\nBinder 1: \nTabs shall have all JCAHO-required documentation requirements only: Sample mandatory documentation requirements for JCAHO are EC.01.02.05, EPs 1-5, 9, and 19. Note, these requirements could change, and it is up to the Contractor to ensure documentation contains the most current requirements per JCAHO. \nIf an EC/EP Component contains documentation requirement for more than one (1) device, sub tabs will be created so that each separately-grouped device under a single EC/EP identifier has its own unique section. Example: EC.02.03.05, EP9.\nEach tab shall have a cover sheet specifically delineating JCAHO (EC/EP identifier) and NFPA requirements verbatim out of the most current standard or edition. 6.4.1.4 Each tab shall have a second cover sheet defining time/testing interval requirements for the specific tabbed item per NFPA and JCAHO individually.\nBinder 2:\nAll other Fire Suppression testing requirements will be contained within a secondary binder. \nThe binder will match Binder 1 in regard to organization and set-up.\nIf a device fails, the Contractor will initiate a Deficiency Notification (DN) via electronic correspondence to Service POC/COR identifying device (description/UID), location, date, and discovered fault.\nThe same DN will remain open/un-resolved until repairs are concluded. The comments on a DN will identify all repair activities, UID s of any equipment removed and new UID s of any new equipment added to the system. Ultimately the DN must contain the test results after each repair is completed\n\nAs-Built CAD Drawings:\nReview and update As-Built CAD Drawings to show all Alarm System Panels, Components, Sensors, and Wiring.\nVerify As-Built drawings are accurate. Semi-Annual & Annual review by contractor to ensure accuracy.\nCurrent As-Built drawings will be provided by VA after contract award. Drawings shall also show the Barcode ID and Fire Alarm panel address (for example: 001-01-05-123). Coordinate with VA Fire Alarm Contractor. Contractor shall review and redline As-Built AutoCAD drawing layers to show location and identify the following components:\nTamper Switches/Control Valves\nFlow Switches\nAnsul R-102 Kitchen Hood Suppression System. Include electrical shunt trips\nFire Extinguisher locations with barcode ID#\nAir Compressors\nPressure switches\nFM-200 systems\nStandpipes\nRisers\nFDC s\nHose Connections\nAlarm Valves\nDrains\nMain Drains\nSprinkler Head Boxes with quantity and type of spares\nPIV s\nAny functional fire suppression or alarm component not shown on existing drawings. This is requested so that VA shall will have comprehensive Fire Suppression System Plans.\nSix (6) months prior to contract expiration, vendor shall provide current As-Built drawings fully updated with all fire alarm system components, provided in AutoCAD and hard copies ARCH C 18  x 24 .\n\nQuality Assurance:\nContractor shall have NICET qualified staff.\nTesting Procedures shall be performed in accordance with NFPA 25, 72 & 105, or more frequently, in accordance with of Authority Having Jurisdiction. The NFPA 72 shows testing frequencies.\nWet Sprinkler System Inspection Summary - Inspect general items such as:\nAre all systems in service?\nVisualize location of heads in relationship to the distance of walls, ceilings & objects. Does the building appear to be properly heated in all areas?\nDo all exterior openings appear to be protected against freezing?\nInspect control valves:\nAre all valves in the appropriate open or closed position?\nMake sure all shut off valves are chained, locked & tamper proof. Exercise all O, S, & Y valves.\nWater supplies: Do a full flow of water test of the main drain at the sprinkler riser.\nInspect Fire Department Connections:\nConfirm that fire department connections are in satisfactory condition\nConfirm that the connection is couplings free, caps in place & check valves tight.\nConfirm that the connection is accessible and visible.\nAlarms:\nTest water motor and gong.\nTest electric alarm.\nTest supervisory alarm service.\nSprinklers:\nVerify that all sprinklers are free from corrosion, loading, or obstruction to spray discharge.\nCheck that sprinklers are less than 50 years old - thus not requiring sample testing.\nVerify that there is a stock of spare sprinklers available.\nCheck that the exterior condition of the sprinkler system is in good condition and working order.\nVerify that all sprinklers are of proper temperature ratings for their locations.\nReplace gauges as needed. All gauges must be calibrated or replaced every five (5) years.\nInspect tamper and flow switches. Note sprinkler valve size, static pressure, and residual pressure for report.\nAll activities (maintenance, testing and inspection) shall be noted in written Service Report to Service POC/COR. Final periodic Inspection/Tests shall be reported electronically, using http://www.buildingreports.com.\n\nInvoices: Each invoice shall document the service(s) completed. The Service POC/COR will review and provide a stamped Progress Report combined with Contractor s invoice to be electronically uploaded. \n\nDAYS & HOURS OF OPERATION\nNormal business hours are Monday through Friday, from 8:00 am to 4:30 pm, excluding any federal holiday.\nFederal holidays, including any days specifically declared by the President of the United States to be a national holiday, can be found at: https://www.opm.gov/policy-data-oversight/pay-leave/federal-holidays/.\nWork under this contract must be performed during normal business hours.","origin":"detail"},"contacts":[{"name":"Jeannie Ortiz","role":"primary","email":"jeanne.ortiz@va.gov","phone":"NO PHONE CALLS ACCEPTED","title":"Contracting Officer"}],"place_of_performance":{"zip":"48602","city":{"name":"REGARD TO THIS SOURCES SOUGHT NOTICE"},"street":"Saginaw VA Medical Center 1500 Weiss Street","country":{"code":"USA","name":"UNITED STATES"},"street2":"Saginaw, MI 48602 VENDORS - DO NOT CONTACT THE FACILITY IN"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"naics_codes":["238220"],"award":{"awardee":{}},"attachments":[{"resource_id":"42723d2f8c5d4e72b567d47f39246958","name":"36C25025Q0899.docx","kind":"file","mime_type":".docx","size_bytes":29905,"posted_at":"2025-09-02T12:12:05.649Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/42723d2f8c5d4e72b567d47f39246958/download","mirrored":false}],"awards":[],"related":[{"key":"36C25027Q0113","latest_notice_id":"30f6d444e0f641e5b23d5b4c1ec5a384","title":"Q301--Prostate Reference Lab Testing Services","solicitation_number":"36C25027Q0113","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-25T21:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"621511","psc":"Q301","set_aside":null,"state":"OH","county":"39049","county_name":"Franklin County","city":"3918000","city_name":"Columbus","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C25027Q0014","latest_notice_id":"b13cc87179e947e7b42da2de44a6bde1","title":"J061--541 Electrical Power Distribution Equipment Testing, Inspection, and Maintenance - VAMC Cleveland","solicitation_number":"36C25027Q0014","notice_type":"k","first_type":"k","first_posted":"2026-10-09","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"238210","psc":"J061","set_aside":"SBA","state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C25027Q0123","latest_notice_id":"fb53a332644a4c8fa983bf28c8643d2d","title":"S222--Sources Sought - Hazardous Waste Removal/Disposal Northeast Ohio VA Healthcare System - Cleveland, OH","solicitation_number":"36C25027Q0123","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T18:30:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"562112","psc":"S222","set_aside":null,"state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C25027B0009","latest_notice_id":"85b83d408f1f422885991142c2734b45","title":"Z1DA--FY27 NRM - VISN Base Modernize Nurse Call - 539-23-101","solicitation_number":"36C25027B0009","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"},{"key":"36C25027B0008","latest_notice_id":"5afe716a38494a6f84b1e84205805f86","title":"Z1DA--FY27 NRM - VISN Base Install Roof Equipment Railings - 539-22-206","solicitation_number":"36C25027B0008","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"}],"similar_open":[{"key":"W911PT27QA020","latest_notice_id":"084d5efc5ec44a9885a37b90e6705ffa","title":"REMOVE AND REPAIR TWO HIGH VELOCITY AIR HANDLING UNITS","solicitation_number":"W911PT27QA020","notice_type":"k","first_type":"k","first_posted":"2026-11-05","last_posted":"2026-11-05","notices":1,"due_at":"2026-11-25T18:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911PT","office_name":"W6QK ACC WVA","naics":"238220","psc":"Z2NB","set_aside":"SBA","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"IGH VELOCITY AIR HANDLING UNITSPROJECT LOCATION: WATERVLIET ARSENAL","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-06T04:46:59.158685Z"},{"key":"2031ZA27B00001","latest_notice_id":"622efd27a6cf48589063c08d3700b96b","title":"Modernize Regenerative Thermal Oxidizer (RTO)","solicitation_number":"2031ZA27B00001","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-25T21:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-020","dept_name":"TREASURY, DEPARTMENT OF THE","sub_key":"s-2041","sub_name":"BUREAU OF ENGRAVING AND PRINTING","office_key":"o-2031ZA","office_name":"OFFICE OF THE CHIEF PROCUREMENT OFFICER","naics":"238220","psc":"Z2AZ","set_aside":null,"state":"TX","county":"48439","county_name":"Tarrant County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"140PP027B0004","latest_notice_id":"53398cb59b8f4b0687efd4e3fa6241dc","title":"Z--13976 PUHO FIRE PROTECTION AT DORM","solicitation_number":"140PP027B0004","notice_type":"r","first_type":"s","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":2,"due_at":"2026-11-26T03:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-26T03:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-014","dept_name":"INTERIOR, DEPARTMENT OF THE","sub_key":"s-1406","sub_name":"DEPARTMENTAL OFFICES","office_key":"o-140PP0","office_name":"NATIONAL PARK SERVICE CONTRACTING ACTIVITY","naics":"238220","psc":"Z2AA","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open_total":59,"indexable":false}