{"canonical":"https://sealedbidder.com/opportunities/36c25025q0691","key":"36C25025Q0691","url":"https://sealedbidder.com/opportunities/36c25025q0691","title":"6515--Scanlan Endoscopic Surgical Instruments, IND","solicitation_number":"36C25025Q0691","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-07-07T13:00:00Z","first_posted":"2025-06-30","last_posted":"2025-06-30","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"339112","psc":"6515","set_aside":null,"place_state":"IN","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"18097","place_county_name":"Marion County","place_city":"1836003","place_city_name":"Indianapolis","winner":"APPLETON MEDICAL SERVICES, INC.","award_amount":null,"publications":[{"notice_id":"3eed78ea4b4b4b708225917099daec60","title":"6515--Scanlan Endoscopic Surgical Instruments, IND","solicitation_number":"36C25025Q0691","notice_type":"k","base_type":"k","posted":"2025-06-30","posted_at":"2025-06-30T19:23:57.647Z","due_at":"2025-07-07T13:00:00Z","due_date":"2025-07-07","cancelled":false,"archived":true,"archive_date":"2025-08-06","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/3eed78ea4b4b4b708225917099daec60/view","enriched":true,"history":[{"index":3,"title":"6515--Scanlan Endoscopic Surgical Instruments, IND","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-30T19:23:57.647Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"3eed78ea4b4b4b708225917099daec60","solicitation_number":"36C25025Q0691"}]}],"latest_notice_id":"3eed78ea4b4b4b708225917099daec60","first_type":"k","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-06-30","posted_at":"2025-06-30T19:23:57.647Z","created_at":"2025-06-30T19:23:55.443Z","modified_at":"2025-08-07T03:55:46.543Z","response_deadline":{"raw":"2025-07-07T09:00:00-04:00","utc":"2025-07-07T13:00:00Z","date":"2025-07-07","time":"09:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/3eed78ea4b4b4b708225917099daec60/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"6515--Scanlan Endoscopic Surgical Instruments, IND","agency":{"office":{"code":"36C250","name":"250-NETWORK CONTRACT OFFICE 10 (36C250)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"organization_id":"100167099","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-08-06","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--Scanlan Endoscopic Surgical Instruments, IND","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-30T19:23:57.647Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"3eed78ea4b4b4b708225917099daec60","solicitation_number":"36C25025Q0691"}],"contacts":[{"name":"Percy Johnson","role":"primary","email":"percy.johnson2@va.gov","phone":"614-257-5534","title":"Contracting Officer"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"3eed78ea4b4b4b708225917099daec60","lineage_id":"3eed78ea4b4b4b708225917099daec60","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-11T15:26:34.463829948Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"8361576a302aec01f756337c66e1d21bdad89234c9c2d7fc109cb5d3a29cd168","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-11T15:26:34.463829948Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Combined Synopsis-Solicitation for Commercial Products \nRichard L. Roudebush VAMC \nScanlan Endoscopic Surgical Instruments\n\n\nThis is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6,  Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services,  as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued.\n\nThis solicitation is issued as an RFQ.  The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2025-04, effective April 01, 2025.\n\n\nThis solicitation is Brand Name Only, Unrestricted\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339112- Surgical and Medical Instrument Manufacturing, with a small business size standard of 1,000 Employees.\nThe FSC/PSC is 6515- Medical and Surgical Instruments, Equipment and Supplies.\n\nThe Department of Veterans Affairs, Network Contracting Office 10, 2780 Airport Dr., Suite 340, Columbus, OH 43219 is seeking to purchase six (6) SCANLAN PremierT Jacobson Micro Scissors spring style round handle 125  angled micro fine blades 6-1/2\" / 16.5 cm, six (6) SCANLANr PremierT Jacobson Micro Scissors spring style round handle 90? angled micro fine blades 6-1/2\" / 16.5 cm, two (2) SCANLAN Endoscopic Fine Needle Holder ring handle shanks curved sideways (5mm) with ratchet DIAMOND DUSTT jaws curved sideways 11-1/2\" / 29 cm, two (2) SCANLAN Endoscopic Jacobson Needle Holder round handle (5mm) 30 degree angled down, with ratchet curved DIAMOND DUSTT jaws spring style 12-1/2\" / 32 cm, two (2) SCANLAN Endoscopic Chitwood Knot Tier/Pusher (5mm) 30 degree angled down Fine end for 5.0 suture or smaller 11-3/4\" / 30 cm, Brand Name Only, for the Richard L. Roudebush VAMC, located at 1481 W 10 St, Indianapolis, IN 46202.\n\nInterested and qualified companies shall provide quotations for the following items listed below. Any delivery/freight charges shall be incorporated into the unit price of the TMS system; delivery/freight charges not exceeding $250.00 may be listed separately.\n\n\n\n\n\n \n\nAll interested companies shall provide quotations for the following:\n\nSupplies/Services\n\nLine Item\nDescription\nQuantity\nUnit of Measure\nUnit Price\nTotal Price\n0001\n7007-498 SCANLAN PremierT Jacobson Micro Scissors spring style round handle 125  angled micro fine blades 6-1/2\" / 16.5 cm\n6\nEA\n\n\n0002\n7007-496-6 SCANLANr PremierT Jacobson Micro Scissors spring style round handle 90? angled micro fine blades 6-1/2\" / 16.5 cm\n6\nEA\n\n\n0003\n9009-360 SCANLAN Endoscopic Fine Needle Holder ring handle shanks curved sideways (5mm) with ratchet DIAMOND DUSTT jaws curved sideways 11-1/2\" / 29 cm\n2\nEA\n\n\n0004\n9009-364 SCANLAN Endoscopic Jacobson Needle Holder round handle (5mm) 30 degree angled down, with ratchet curved DIAMOND DUSTT jaws spring style 12-1/2\" / 32 cm\n2\nEA\n\n\n0005 \n9009-380-2 SCANLAN Endoscopic Chitwood Knot Tier/Pusher (5mm) 30 degree angled down Fine end for 5.0 suture or smaller 11-3/4\" / 30 cm\n2\nEA\n\n\n\n\nSalient Characteristics\n\nProduct Name:\nScanlanÂ® Premier  Jacobson Micro Scissors\n\nGeneral Description:\nMicro scissors designed for precision surgical procedures, specifically vascular and microsurgery applications. Instruments must be of high-quality surgical stainless steel, provide precise control with a spring handle mechanism, and be balanced for ease of use in delicate procedures.\n________________________________________\nRequired Features:\n1. Scissor Style & Handle:\nSpring style handle\nRound handle for ergonomic grip and surgical control\n2. Blade Specifications:\nMicro fine blade\nAngled blade configurations (125Â° and 90Â°)\n3. Blade Lengths:\n6-1/2 inches (16.5 cm)\n4. Blade Type Options:\n125Â° angled micro fine blade (6-1/2  / 16.5 cm)\n90Â° angled micro fine blade (6-1/2  / 16.5 cm)\n5. Materials:\nHigh-grade stainless steel, suitable for repeated sterilization\nCorrosion-resistant and durable construction for long-term surgical use\n6. Packaging and Quantity:\nItems sold individually, packaged sterile or in accordance with FDA medical device regulations\nMust be available in quantities of 6 or more per order\n7. Shipping Requirements:\nEstimated ground shipping should be included\nItems to be shipped to: Richard L. Roudebush VA Medical Center, Indianapolis, IN\nApproved Manufacturer/Brand Name:\nScanlan International\nPart Numbers:\n7007-498 (125Â° blade)\n7007-496 (90Â° blade)\n\nThe Scanlan Model Numbers 9009-360, 9009-364, and 9009-380 are part of the Scanlan product line, known for their innovative design and functionality. Below are some salient characteristics for these models:\n Scanlan Model 9009-360\n- Design: Compact and ergonomic design suitable for various applications.\n- Capacity: High load capacity for handling demanding tasks.\n- Material: Constructed with durable materials for longevity and reliability.\n- Performance: Optimized for efficient performance with low energy consumption.\n- Features: User-friendly interface with advanced control options.\n\n Scanlan Model 9009-364\n- Versatility: Multi-functional capabilities for diverse operational needs.\n- Size: Designed to fit into tight spaces while maintaining performance.\n- Technology: Incorporates the latest technology for enhanced functionality.\n- Safety: Equipped with safety features to ensure user protection.\n- Maintenance: Low maintenance requirements with easy access to parts.\n\nScanlan Model 9009-380\n- Power: Higher power output for more demanding applications.\n-Efficiency: Enhanced energy efficiency to reduce operational costs.\n- Customization: Options for customization to meet specific user requirements.\n- Durability: Built to withstand harsh environments and heavy usage.\n- Support: Backed by comprehensive customer support and warranty options.\n\n________________________________________\nCompliance:\n\nAll items must be compliant with FDA medical device regulations and suitable for use in VA medical surgical settings\n\nDelivery FOB Destination 30 Days after receipt of order (ARO).\n\nPlace of Performance/Place of Delivery\nAddress:\nRichard L. Roudebush VAMC, located at 1481 W 10 St, Indianapolis, IN \nPostal Code:\n46202\nCountry:\nUNITED STATES\n\nAll quoters shall submit the following: \n\n(1) Price quote.\n(2) Product technical information.\n(3) Completed FAR 52.212-3, Offerors Representations and Certifications   Commercial Products and Commercial Services.\n\n\nAll quotes shall be sent to the Contracting Officer, Percy Johnson, via email at percy.johnson2@va.gov\n\nAward will be based upon lowest price technically acceptable criteria in accordance with the Simplified Acquisition Procedures of FAR 13. \n\nTo facilitate the award process, all quotes must include a statement regarding the terms and conditions herein as follows:\n\"The terms and conditions in the solicitation are acceptable to be included in the award document without modification, deletion, or addition.\"\nOR\n\"The terms and conditions in the solicitation are acceptable to be included in the award document with the exception, deletion, or addition of the following:\"\nQuoters shall list exception(s) and rationale for the exception(s), if any.\n\nSubmission of your response shall be received not later than 9:00 AM Eastern Time, Monday, July 07, 2025, by email at percy.johnson2@va.gov. \n\nLate submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f).  \n\nAny questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below. \nPoint of Contact\nPoint of contact for this solicitation is Percy Johnson, Contracting Officer, email: percy.johnson2@va.gov.","text":"Combined Synopsis-Solicitation for Commercial Products\nRichard L. Roudebush VAMC\nScanlan Endoscopic Surgical Instruments\n\nThis is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued.\n\nThis solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2025-04, effective April 01, 2025.\n\nThis solicitation is Brand Name Only, Unrestricted\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339112- Surgical and Medical Instrument Manufacturing, with a small business size standard of 1,000 Employees.\nThe FSC/PSC is 6515- Medical and Surgical Instruments, Equipment and Supplies.\n\nThe Department of Veterans Affairs, Network Contracting Office 10, 2780 Airport Dr., Suite 340, Columbus, OH 43219 is seeking to purchase six (6) SCANLAN PremierT Jacobson Micro Scissors spring style round handle 125 angled micro fine blades 6-1/2\" / 16.5 cm, six (6) SCANLANr PremierT Jacobson Micro Scissors spring style round handle 90? angled micro fine blades 6-1/2\" / 16.5 cm, two (2) SCANLAN Endoscopic Fine Needle Holder ring handle shanks curved sideways (5mm) with ratchet DIAMOND DUSTT jaws curved sideways 11-1/2\" / 29 cm, two (2) SCANLAN Endoscopic Jacobson Needle Holder round handle (5mm) 30 degree angled down, with ratchet curved DIAMOND DUSTT jaws spring style 12-1/2\" / 32 cm, two (2) SCANLAN Endoscopic Chitwood Knot Tier/Pusher (5mm) 30 degree angled down Fine end for 5.0 suture or smaller 11-3/4\" / 30 cm, Brand Name Only, for the Richard L. Roudebush VAMC, located at 1481 W 10 St, Indianapolis, IN 46202.\n\nInterested and qualified companies shall provide quotations for the following items listed below. Any delivery/freight charges shall be incorporated into the unit price of the TMS system; delivery/freight charges not exceeding $250.00 may be listed separately.\n\nAll interested companies shall provide quotations for the following:\n\nSupplies/Services\n\nLine Item\nDescription\nQuantity\nUnit of Measure\nUnit Price\nTotal Price\n0001\n7007-498 SCANLAN PremierT Jacobson Micro Scissors spring style round handle 125 angled micro fine blades 6-1/2\" / 16.5 cm\n6\nEA\n\n0002\n7007-496-6 SCANLANr PremierT Jacobson Micro Scissors spring style round handle 90? angled micro fine blades 6-1/2\" / 16.5 cm\n6\nEA\n\n0003\n9009-360 SCANLAN Endoscopic Fine Needle Holder ring handle shanks curved sideways (5mm) with ratchet DIAMOND DUSTT jaws curved sideways 11-1/2\" / 29 cm\n2\nEA\n\n0004\n9009-364 SCANLAN Endoscopic Jacobson Needle Holder round handle (5mm) 30 degree angled down, with ratchet curved DIAMOND DUSTT jaws spring style 12-1/2\" / 32 cm\n2\nEA\n\n0005\n9009-380-2 SCANLAN Endoscopic Chitwood Knot Tier/Pusher (5mm) 30 degree angled down Fine end for 5.0 suture or smaller 11-3/4\" / 30 cm\n2\nEA\n\nSalient Characteristics\n\nProduct Name:\nScanlanÂ® Premier Jacobson Micro Scissors\n\nGeneral Description:\nMicro scissors designed for precision surgical procedures, specifically vascular and microsurgery applications. Instruments must be of high-quality surgical stainless steel, provide precise control with a spring handle mechanism, and be balanced for ease of use in delicate procedures.\n________________________________________\nRequired Features:\n1. Scissor Style & Handle:\nSpring style handle\nRound handle for ergonomic grip and surgical control\n2. Blade Specifications:\nMicro fine blade\nAngled blade configurations (125Â° and 90Â°)\n3. Blade Lengths:\n6-1/2 inches (16.5 cm)\n4. Blade Type Options:\n125Â° angled micro fine blade (6-1/2 / 16.5 cm)\n90Â° angled micro fine blade (6-1/2 / 16.5 cm)\n5. Materials:\nHigh-grade stainless steel, suitable for repeated sterilization\nCorrosion-resistant and durable construction for long-term surgical use\n6. Packaging and Quantity:\nItems sold individually, packaged sterile or in accordance with FDA medical device regulations\nMust be available in quantities of 6 or more per order\n7. Shipping Requirements:\nEstimated ground shipping should be included\nItems to be shipped to: Richard L. Roudebush VA Medical Center, Indianapolis, IN\nApproved Manufacturer/Brand Name:\nScanlan International\nPart Numbers:\n7007-498 (125Â° blade)\n7007-496 (90Â° blade)\n\nThe Scanlan Model Numbers 9009-360, 9009-364, and 9009-380 are part of the Scanlan product line, known for their innovative design and functionality. Below are some salient characteristics for these models:\nScanlan Model 9009-360\n- Design: Compact and ergonomic design suitable for various applications.\n- Capacity: High load capacity for handling demanding tasks.\n- Material: Constructed with durable materials for longevity and reliability.\n- Performance: Optimized for efficient performance with low energy consumption.\n- Features: User-friendly interface with advanced control options.\n\nScanlan Model 9009-364\n- Versatility: Multi-functional capabilities for diverse operational needs.\n- Size: Designed to fit into tight spaces while maintaining performance.\n- Technology: Incorporates the latest technology for enhanced functionality.\n- Safety: Equipped with safety features to ensure user protection.\n- Maintenance: Low maintenance requirements with easy access to parts.\n\nScanlan Model 9009-380\n- Power: Higher power output for more demanding applications.\n-Efficiency: Enhanced energy efficiency to reduce operational costs.\n- Customization: Options for customization to meet specific user requirements.\n- Durability: Built to withstand harsh environments and heavy usage.\n- Support: Backed by comprehensive customer support and warranty options.\n\n________________________________________\nCompliance:\n\nAll items must be compliant with FDA medical device regulations and suitable for use in VA medical surgical settings\n\nDelivery FOB Destination 30 Days after receipt of order (ARO).\n\nPlace of Performance/Place of Delivery\nAddress:\nRichard L. Roudebush VAMC, located at 1481 W 10 St, Indianapolis, IN\nPostal Code:\n46202\nCountry:\nUNITED STATES\n\nAll quoters shall submit the following:\n\n(1) Price quote.\n(2) Product technical information.\n(3) Completed FAR 52.212-3, Offerors Representations and Certifications Commercial Products and Commercial Services.\n\nAll quotes shall be sent to the Contracting Officer, Percy Johnson, via email at percy.johnson2@va.gov\n\nAward will be based upon lowest price technically acceptable criteria in accordance with the Simplified Acquisition Procedures of FAR 13.\n\nTo facilitate the award process, all quotes must include a statement regarding the terms and conditions herein as follows:\n\"The terms and conditions in the solicitation are acceptable to be included in the award document without modification, deletion, or addition.\"\nOR\n\"The terms and conditions in the solicitation are acceptable to be included in the award document with the exception, deletion, or addition of the following:\"\nQuoters shall list exception(s) and rationale for the exception(s), if any.\n\nSubmission of your response shall be received not later than 9:00 AM Eastern Time, Monday, July 07, 2025, by email at percy.johnson2@va.gov.\n\nLate submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f).\n\nAny questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below.\nPoint of Contact\nPoint of contact for this solicitation is Percy Johnson, Contracting Officer, email: percy.johnson2@va.gov.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C25025Q0691","place_of_performance":{"zip":"46202","city":{"code":"36000","name":"Indianapolis"},"state":{"code":"IN","name":"Indiana"},"street":"Department of Veterans Affairs Richard L. Roudebush VAMC","country":{"code":"USA","name":"UNITED STATES"},"street2":"1481 W 10 St"},"product_service_code":"6515"}],"due_at":"2025-07-07T13:00:00Z","due_date":"2025-07-07","closes_at":"2025-07-07T13:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","state":"IN","county":"18097","county_name":"Marion County","city":"1836003","city_name":"Indianapolis","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"WCUFLK9J2AG8","amount":null,"linked_awards":1,"cancelled":false,"archived":true,"updated_at":"2026-11-11T15:46:04.398708Z","principal_notice_id":"3eed78ea4b4b4b708225917099daec60","description":{"text":"Combined Synopsis-Solicitation for Commercial Products\nRichard L. Roudebush VAMC\nScanlan Endoscopic Surgical Instruments\n\nThis is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued.\n\nThis solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2025-04, effective April 01, 2025.\n\nThis solicitation is Brand Name Only, Unrestricted\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339112- Surgical and Medical Instrument Manufacturing, with a small business size standard of 1,000 Employees.\nThe FSC/PSC is 6515- Medical and Surgical Instruments, Equipment and Supplies.\n\nThe Department of Veterans Affairs, Network Contracting Office 10, 2780 Airport Dr., Suite 340, Columbus, OH 43219 is seeking to purchase six (6) SCANLAN PremierT Jacobson Micro Scissors spring style round handle 125 angled micro fine blades 6-1/2\" / 16.5 cm, six (6) SCANLANr PremierT Jacobson Micro Scissors spring style round handle 90? angled micro fine blades 6-1/2\" / 16.5 cm, two (2) SCANLAN Endoscopic Fine Needle Holder ring handle shanks curved sideways (5mm) with ratchet DIAMOND DUSTT jaws curved sideways 11-1/2\" / 29 cm, two (2) SCANLAN Endoscopic Jacobson Needle Holder round handle (5mm) 30 degree angled down, with ratchet curved DIAMOND DUSTT jaws spring style 12-1/2\" / 32 cm, two (2) SCANLAN Endoscopic Chitwood Knot Tier/Pusher (5mm) 30 degree angled down Fine end for 5.0 suture or smaller 11-3/4\" / 30 cm, Brand Name Only, for the Richard L. Roudebush VAMC, located at 1481 W 10 St, Indianapolis, IN 46202.\n\nInterested and qualified companies shall provide quotations for the following items listed below. Any delivery/freight charges shall be incorporated into the unit price of the TMS system; delivery/freight charges not exceeding $250.00 may be listed separately.\n\nAll interested companies shall provide quotations for the following:\n\nSupplies/Services\n\nLine Item\nDescription\nQuantity\nUnit of Measure\nUnit Price\nTotal Price\n0001\n7007-498 SCANLAN PremierT Jacobson Micro Scissors spring style round handle 125 angled micro fine blades 6-1/2\" / 16.5 cm\n6\nEA\n\n0002\n7007-496-6 SCANLANr PremierT Jacobson Micro Scissors spring style round handle 90? angled micro fine blades 6-1/2\" / 16.5 cm\n6\nEA\n\n0003\n9009-360 SCANLAN Endoscopic Fine Needle Holder ring handle shanks curved sideways (5mm) with ratchet DIAMOND DUSTT jaws curved sideways 11-1/2\" / 29 cm\n2\nEA\n\n0004\n9009-364 SCANLAN Endoscopic Jacobson Needle Holder round handle (5mm) 30 degree angled down, with ratchet curved DIAMOND DUSTT jaws spring style 12-1/2\" / 32 cm\n2\nEA\n\n0005\n9009-380-2 SCANLAN Endoscopic Chitwood Knot Tier/Pusher (5mm) 30 degree angled down Fine end for 5.0 suture or smaller 11-3/4\" / 30 cm\n2\nEA\n\nSalient Characteristics\n\nProduct Name:\nScanlanÂ® Premier Jacobson Micro Scissors\n\nGeneral Description:\nMicro scissors designed for precision surgical procedures, specifically vascular and microsurgery applications. Instruments must be of high-quality surgical stainless steel, provide precise control with a spring handle mechanism, and be balanced for ease of use in delicate procedures.\n________________________________________\nRequired Features:\n1. Scissor Style & Handle:\nSpring style handle\nRound handle for ergonomic grip and surgical control\n2. Blade Specifications:\nMicro fine blade\nAngled blade configurations (125Â° and 90Â°)\n3. Blade Lengths:\n6-1/2 inches (16.5 cm)\n4. Blade Type Options:\n125Â° angled micro fine blade (6-1/2 / 16.5 cm)\n90Â° angled micro fine blade (6-1/2 / 16.5 cm)\n5. Materials:\nHigh-grade stainless steel, suitable for repeated sterilization\nCorrosion-resistant and durable construction for long-term surgical use\n6. Packaging and Quantity:\nItems sold individually, packaged sterile or in accordance with FDA medical device regulations\nMust be available in quantities of 6 or more per order\n7. Shipping Requirements:\nEstimated ground shipping should be included\nItems to be shipped to: Richard L. Roudebush VA Medical Center, Indianapolis, IN\nApproved Manufacturer/Brand Name:\nScanlan International\nPart Numbers:\n7007-498 (125Â° blade)\n7007-496 (90Â° blade)\n\nThe Scanlan Model Numbers 9009-360, 9009-364, and 9009-380 are part of the Scanlan product line, known for their innovative design and functionality. Below are some salient characteristics for these models:\nScanlan Model 9009-360\n- Design: Compact and ergonomic design suitable for various applications.\n- Capacity: High load capacity for handling demanding tasks.\n- Material: Constructed with durable materials for longevity and reliability.\n- Performance: Optimized for efficient performance with low energy consumption.\n- Features: User-friendly interface with advanced control options.\n\nScanlan Model 9009-364\n- Versatility: Multi-functional capabilities for diverse operational needs.\n- Size: Designed to fit into tight spaces while maintaining performance.\n- Technology: Incorporates the latest technology for enhanced functionality.\n- Safety: Equipped with safety features to ensure user protection.\n- Maintenance: Low maintenance requirements with easy access to parts.\n\nScanlan Model 9009-380\n- Power: Higher power output for more demanding applications.\n-Efficiency: Enhanced energy efficiency to reduce operational costs.\n- Customization: Options for customization to meet specific user requirements.\n- Durability: Built to withstand harsh environments and heavy usage.\n- Support: Backed by comprehensive customer support and warranty options.\n\n________________________________________\nCompliance:\n\nAll items must be compliant with FDA medical device regulations and suitable for use in VA medical surgical settings\n\nDelivery FOB Destination 30 Days after receipt of order (ARO).\n\nPlace of Performance/Place of Delivery\nAddress:\nRichard L. Roudebush VAMC, located at 1481 W 10 St, Indianapolis, IN\nPostal Code:\n46202\nCountry:\nUNITED STATES\n\nAll quoters shall submit the following:\n\n(1) Price quote.\n(2) Product technical information.\n(3) Completed FAR 52.212-3, Offerors Representations and Certifications Commercial Products and Commercial Services.\n\nAll quotes shall be sent to the Contracting Officer, Percy Johnson, via email at percy.johnson2@va.gov\n\nAward will be based upon lowest price technically acceptable criteria in accordance with the Simplified Acquisition Procedures of FAR 13.\n\nTo facilitate the award process, all quotes must include a statement regarding the terms and conditions herein as follows:\n\"The terms and conditions in the solicitation are acceptable to be included in the award document without modification, deletion, or addition.\"\nOR\n\"The terms and conditions in the solicitation are acceptable to be included in the award document with the exception, deletion, or addition of the following:\"\nQuoters shall list exception(s) and rationale for the exception(s), if any.\n\nSubmission of your response shall be received not later than 9:00 AM Eastern Time, Monday, July 07, 2025, by email at percy.johnson2@va.gov.\n\nLate submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f).\n\nAny questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below.\nPoint of Contact\nPoint of contact for this solicitation is Percy Johnson, Contracting Officer, email: percy.johnson2@va.gov.","html":"Combined Synopsis-Solicitation for Commercial Products \nRichard L. Roudebush VAMC \nScanlan Endoscopic Surgical Instruments\n\n\nThis is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6,  Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services,  as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued.\n\nThis solicitation is issued as an RFQ.  The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2025-04, effective April 01, 2025.\n\n\nThis solicitation is Brand Name Only, Unrestricted\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339112- Surgical and Medical Instrument Manufacturing, with a small business size standard of 1,000 Employees.\nThe FSC/PSC is 6515- Medical and Surgical Instruments, Equipment and Supplies.\n\nThe Department of Veterans Affairs, Network Contracting Office 10, 2780 Airport Dr., Suite 340, Columbus, OH 43219 is seeking to purchase six (6) SCANLAN PremierT Jacobson Micro Scissors spring style round handle 125  angled micro fine blades 6-1/2\" / 16.5 cm, six (6) SCANLANr PremierT Jacobson Micro Scissors spring style round handle 90? angled micro fine blades 6-1/2\" / 16.5 cm, two (2) SCANLAN Endoscopic Fine Needle Holder ring handle shanks curved sideways (5mm) with ratchet DIAMOND DUSTT jaws curved sideways 11-1/2\" / 29 cm, two (2) SCANLAN Endoscopic Jacobson Needle Holder round handle (5mm) 30 degree angled down, with ratchet curved DIAMOND DUSTT jaws spring style 12-1/2\" / 32 cm, two (2) SCANLAN Endoscopic Chitwood Knot Tier/Pusher (5mm) 30 degree angled down Fine end for 5.0 suture or smaller 11-3/4\" / 30 cm, Brand Name Only, for the Richard L. Roudebush VAMC, located at 1481 W 10 St, Indianapolis, IN 46202.\n\nInterested and qualified companies shall provide quotations for the following items listed below. Any delivery/freight charges shall be incorporated into the unit price of the TMS system; delivery/freight charges not exceeding $250.00 may be listed separately.\n\n\n\n\n\n \n\nAll interested companies shall provide quotations for the following:\n\nSupplies/Services\n\nLine Item\nDescription\nQuantity\nUnit of Measure\nUnit Price\nTotal Price\n0001\n7007-498 SCANLAN PremierT Jacobson Micro Scissors spring style round handle 125  angled micro fine blades 6-1/2\" / 16.5 cm\n6\nEA\n\n\n0002\n7007-496-6 SCANLANr PremierT Jacobson Micro Scissors spring style round handle 90? angled micro fine blades 6-1/2\" / 16.5 cm\n6\nEA\n\n\n0003\n9009-360 SCANLAN Endoscopic Fine Needle Holder ring handle shanks curved sideways (5mm) with ratchet DIAMOND DUSTT jaws curved sideways 11-1/2\" / 29 cm\n2\nEA\n\n\n0004\n9009-364 SCANLAN Endoscopic Jacobson Needle Holder round handle (5mm) 30 degree angled down, with ratchet curved DIAMOND DUSTT jaws spring style 12-1/2\" / 32 cm\n2\nEA\n\n\n0005 \n9009-380-2 SCANLAN Endoscopic Chitwood Knot Tier/Pusher (5mm) 30 degree angled down Fine end for 5.0 suture or smaller 11-3/4\" / 30 cm\n2\nEA\n\n\n\n\nSalient Characteristics\n\nProduct Name:\nScanlanÂ® Premier  Jacobson Micro Scissors\n\nGeneral Description:\nMicro scissors designed for precision surgical procedures, specifically vascular and microsurgery applications. Instruments must be of high-quality surgical stainless steel, provide precise control with a spring handle mechanism, and be balanced for ease of use in delicate procedures.\n________________________________________\nRequired Features:\n1. Scissor Style & Handle:\nSpring style handle\nRound handle for ergonomic grip and surgical control\n2. Blade Specifications:\nMicro fine blade\nAngled blade configurations (125Â° and 90Â°)\n3. Blade Lengths:\n6-1/2 inches (16.5 cm)\n4. Blade Type Options:\n125Â° angled micro fine blade (6-1/2  / 16.5 cm)\n90Â° angled micro fine blade (6-1/2  / 16.5 cm)\n5. Materials:\nHigh-grade stainless steel, suitable for repeated sterilization\nCorrosion-resistant and durable construction for long-term surgical use\n6. Packaging and Quantity:\nItems sold individually, packaged sterile or in accordance with FDA medical device regulations\nMust be available in quantities of 6 or more per order\n7. Shipping Requirements:\nEstimated ground shipping should be included\nItems to be shipped to: Richard L. Roudebush VA Medical Center, Indianapolis, IN\nApproved Manufacturer/Brand Name:\nScanlan International\nPart Numbers:\n7007-498 (125Â° blade)\n7007-496 (90Â° blade)\n\nThe Scanlan Model Numbers 9009-360, 9009-364, and 9009-380 are part of the Scanlan product line, known for their innovative design and functionality. Below are some salient characteristics for these models:\n Scanlan Model 9009-360\n- Design: Compact and ergonomic design suitable for various applications.\n- Capacity: High load capacity for handling demanding tasks.\n- Material: Constructed with durable materials for longevity and reliability.\n- Performance: Optimized for efficient performance with low energy consumption.\n- Features: User-friendly interface with advanced control options.\n\n Scanlan Model 9009-364\n- Versatility: Multi-functional capabilities for diverse operational needs.\n- Size: Designed to fit into tight spaces while maintaining performance.\n- Technology: Incorporates the latest technology for enhanced functionality.\n- Safety: Equipped with safety features to ensure user protection.\n- Maintenance: Low maintenance requirements with easy access to parts.\n\nScanlan Model 9009-380\n- Power: Higher power output for more demanding applications.\n-Efficiency: Enhanced energy efficiency to reduce operational costs.\n- Customization: Options for customization to meet specific user requirements.\n- Durability: Built to withstand harsh environments and heavy usage.\n- Support: Backed by comprehensive customer support and warranty options.\n\n________________________________________\nCompliance:\n\nAll items must be compliant with FDA medical device regulations and suitable for use in VA medical surgical settings\n\nDelivery FOB Destination 30 Days after receipt of order (ARO).\n\nPlace of Performance/Place of Delivery\nAddress:\nRichard L. Roudebush VAMC, located at 1481 W 10 St, Indianapolis, IN \nPostal Code:\n46202\nCountry:\nUNITED STATES\n\nAll quoters shall submit the following: \n\n(1) Price quote.\n(2) Product technical information.\n(3) Completed FAR 52.212-3, Offerors Representations and Certifications   Commercial Products and Commercial Services.\n\n\nAll quotes shall be sent to the Contracting Officer, Percy Johnson, via email at percy.johnson2@va.gov\n\nAward will be based upon lowest price technically acceptable criteria in accordance with the Simplified Acquisition Procedures of FAR 13. \n\nTo facilitate the award process, all quotes must include a statement regarding the terms and conditions herein as follows:\n\"The terms and conditions in the solicitation are acceptable to be included in the award document without modification, deletion, or addition.\"\nOR\n\"The terms and conditions in the solicitation are acceptable to be included in the award document with the exception, deletion, or addition of the following:\"\nQuoters shall list exception(s) and rationale for the exception(s), if any.\n\nSubmission of your response shall be received not later than 9:00 AM Eastern Time, Monday, July 07, 2025, by email at percy.johnson2@va.gov. \n\nLate submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f).  \n\nAny questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below. \nPoint of Contact\nPoint of contact for this solicitation is Percy Johnson, Contracting Officer, email: percy.johnson2@va.gov.","origin":"detail"},"contacts":[{"name":"Percy Johnson","role":"primary","email":"percy.johnson2@va.gov","phone":"614-257-5534","title":"Contracting Officer"}],"place_of_performance":{"zip":"46202","city":{"code":"36000","name":"Indianapolis"},"state":{"code":"IN","name":"Indiana"},"street":"Department of Veterans Affairs Richard L. Roudebush VAMC","country":{"code":"USA","name":"UNITED STATES"},"street2":"1481 W 10 St"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"naics_codes":["339112"],"award":{"awardee":{}},"attachments":[{"resource_id":"2c47a76aedf944ca9ce1ef39b9500c0a","name":"va.gov","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2025-06-30T19:23:57.647Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov","mirrored":false},{"resource_id":"1ccf4fa683824571b9857052c33e7993","name":"36C25025Q0691_1.docx","kind":"file","mime_type":".docx","size_bytes":82353,"posted_at":"2025-06-30T19:23:57.647Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/1ccf4fa683824571b9857052c33e7993/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C25025P1392_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C25025P1392_3600_-NONE-_-NONE-/","piid":"36C25025P1392","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"WCUFLK9J2AG8","recipient_name":"APPLETON MEDICAL SERVICES, INC.","recipient_uei":"WCUFLK9J2AG8","recipient_cage":"4FZB4","recipient_city":"SAINT CHARLES","recipient_state":"MO","sub_name":"Department of Veterans Affairs","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","office_key":"o-36C250","first_action_date":"2025-07-17","last_action_date":"2025-07-17","actions":1,"obligated":"34620.00","current_total_value":"34620.00","potential_total_value":"34620.00","naics":"339112","psc":"6515","extent_competed":"COMPETED UNDER SAP","set_aside":"NO SET ASIDE USED.","offers_received":1,"description":"SCANLAN ENDOSCOPIC INSTRUMENTS","method":"solicitation","confidence":"high","evidence":["solicitation number 36C25025Q0691 equals the FPDS solicitation identifier","same awarding office 36C250"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C25027Q0014","latest_notice_id":"b13cc87179e947e7b42da2de44a6bde1","title":"J061--541 Electrical Power Distribution Equipment Testing, Inspection, and Maintenance - VAMC Cleveland","solicitation_number":"36C25027Q0014","notice_type":"k","first_type":"k","first_posted":"2026-10-09","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"238210","psc":"J061","set_aside":"SBA","state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C25027Q0123","latest_notice_id":"fb53a332644a4c8fa983bf28c8643d2d","title":"S222--Sources Sought - Hazardous Waste Removal/Disposal Northeast Ohio VA Healthcare System - Cleveland, OH","solicitation_number":"36C25027Q0123","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T18:30:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"562112","psc":"S222","set_aside":null,"state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C25027B0009","latest_notice_id":"85b83d408f1f422885991142c2734b45","title":"Z1DA--FY27 NRM - VISN Base Modernize Nurse Call - 539-23-101","solicitation_number":"36C25027B0009","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"},{"key":"36C25027B0008","latest_notice_id":"5afe716a38494a6f84b1e84205805f86","title":"Z1DA--FY27 NRM - VISN Base Install Roof Equipment Railings - 539-22-206","solicitation_number":"36C25027B0008","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"},{"key":"36C25027B0005","latest_notice_id":"2cb4a6354be04cc89c5d6125945b1892","title":"Z1DA--***FY27 Requirement*** First Floor X Ray - Room CC157 553-CSI-022","solicitation_number":"36C25027B0005","notice_type":"p","first_type":"p","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"MI","county":"26163","county_name":"Wayne County","city":"2622000","city_name":"Detroit","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"}],"similar_open":[{"key":"W911S227U0200","latest_notice_id":"153aef7d00e740188276deb8422a2297","title":"Automated External Defibrillator (AED)","solicitation_number":"W911S227U0200","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T20:15:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:15:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24727Q0119","latest_notice_id":"81776fecabf149c9867d6253acdc2478","title":"Vivarium Tunnel Washer","solicitation_number":"36C24727Q0119","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"339112","psc":"6640","set_aside":null,"state":"GA","county":"13089","county_name":"DeKalb County","city":"1322052","city_name":"Decatur","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C10X27Q0025","latest_notice_id":"8c404062fbbc4212bb93120ad204ee50","title":"6515--NX EQ Microscope, Light, Operating, Hand/Plastic Surgery (VA-27-00017958)","solicitation_number":"36C10X27Q0025","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"}],"similar_open_total":15,"indexable":false}