{"canonical":"https://sealedbidder.com/opportunities/36c25025q0419","key":"36C25025Q0419","url":"https://sealedbidder.com/opportunities/36c25025q0419","title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","solicitation_number":"36C25025Q0419","notice_type":"a","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-04-24T16:00:00Z","first_posted":"2025-04-09","last_posted":"2025-05-16","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"238220","psc":"H946","set_aside":"SBA","place_state":"MI","place_scope":"site","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"26077","place_county_name":"Kalamazoo County","place_city":null,"place_city_name":null,"winner":"RLM GOVERNMENT SERVICES LLC","award_amount":"600523.00","publications":[{"notice_id":"d5d703998af145ee95133d1bad209c87","title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","solicitation_number":"36C25025Q0419","notice_type":"p","base_type":"p","posted":"2025-04-09","posted_at":"2025-04-09T19:25:21.063Z","due_at":"2025-04-10T16:00:00Z","due_date":"2025-04-10","cancelled":false,"archived":true,"archive_date":"2025-05-10","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/d5d703998af145ee95133d1bad209c87/view","enriched":true,"history":[{"index":4,"title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T19:25:21.063Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"d5d703998af145ee95133d1bad209c87","solicitation_number":"36C25025Q0419"},{"index":2,"title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-10T12:13:19.982Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"57b5aa987d1c40c68537e18783a96354","solicitation_number":"36C25025Q0419","related_opportunity_id":"d5d703998af145ee95133d1bad209c87"}]},{"notice_id":"57b5aa987d1c40c68537e18783a96354","title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","solicitation_number":"36C25025Q0419","notice_type":"o","base_type":"p","posted":"2025-04-10","posted_at":"2025-04-10T12:13:19.982Z","due_at":"2025-04-24T16:00:00Z","due_date":"2025-04-24","cancelled":false,"archived":true,"archive_date":"2025-05-24","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/57b5aa987d1c40c68537e18783a96354/view","enriched":true,"history":[{"index":6,"title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-17T20:23:42.469Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d79e95c564bd4ba7939dcb3aed6c633e","solicitation_number":"36C25025Q0419","parent_opportunity_id":"57b5aa987d1c40c68537e18783a96354"},{"index":5,"title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T19:25:21.063Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"d5d703998af145ee95133d1bad209c87","solicitation_number":"36C25025Q0419"},{"index":2,"title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-10T12:13:19.982Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"57b5aa987d1c40c68537e18783a96354","solicitation_number":"36C25025Q0419","related_opportunity_id":"d5d703998af145ee95133d1bad209c87"}]},{"notice_id":"d79e95c564bd4ba7939dcb3aed6c633e","title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","solicitation_number":"36C25025Q0419","notice_type":"o","base_type":"o","posted":"2025-04-17","posted_at":"2025-04-17T20:23:42.469Z","due_at":"2025-04-24T16:00:00Z","due_date":"2025-04-24","cancelled":false,"archived":true,"archive_date":"2025-05-24","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/d79e95c564bd4ba7939dcb3aed6c633e/view","enriched":true,"history":[{"index":6,"title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-05-16T20:18:49.762Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"0d86cd9af21d4d7681ff3837ae9958f8","solicitation_number":"36C25025q0419","related_opportunity_id":"d79e95c564bd4ba7939dcb3aed6c633e"},{"index":4,"title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-17T20:23:42.469Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d79e95c564bd4ba7939dcb3aed6c633e","solicitation_number":"36C25025Q0419","parent_opportunity_id":"57b5aa987d1c40c68537e18783a96354"},{"index":1,"title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-10T12:13:19.982Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"57b5aa987d1c40c68537e18783a96354","solicitation_number":"36C25025Q0419","related_opportunity_id":"d5d703998af145ee95133d1bad209c87"}]},{"notice_id":"0d86cd9af21d4d7681ff3837ae9958f8","title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","solicitation_number":"36C25025q0419","notice_type":"a","base_type":"o","posted":"2025-05-16","posted_at":"2025-05-16T20:18:49.762Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2025-06-15","removed_at":null,"award_number":"36C25025C0105","awardee_name":"RLM GOVERNMENT SERVICES LLC","amount":"600523.00","link_sam":"https://sam.gov/workspace/contract/opp/0d86cd9af21d4d7681ff3837ae9958f8/view","enriched":true,"history":[{"index":5,"title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-05-16T20:18:49.762Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"0d86cd9af21d4d7681ff3837ae9958f8","solicitation_number":"36C25025q0419","related_opportunity_id":"d79e95c564bd4ba7939dcb3aed6c633e"},{"index":3,"title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-17T20:23:42.469Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d79e95c564bd4ba7939dcb3aed6c633e","solicitation_number":"36C25025Q0419","parent_opportunity_id":"57b5aa987d1c40c68537e18783a96354"}]}],"latest_notice_id":"0d86cd9af21d4d7681ff3837ae9958f8","first_type":"p","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-04-09","posted_at":"2025-04-09T19:25:21.063Z","created_at":"2025-04-09T19:25:18.835Z","modified_at":"2025-05-10T04:04:32.060Z","response_deadline":{"raw":"2025-04-10T12:00:00-04:00","utc":"2025-04-10T16:00:00Z","date":"2025-04-10","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/d5d703998af145ee95133d1bad209c87/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","agency":{"office":{"code":"36C250","name":"250-NETWORK CONTRACT OFFICE 10 (36C250)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"organization_id":"100167099","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-05-10","archive_type":"auto_custom"},"history":[{"index":4,"title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T19:25:21.063Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"d5d703998af145ee95133d1bad209c87","solicitation_number":"36C25025Q0419"},{"index":2,"title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-10T12:13:19.982Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"57b5aa987d1c40c68537e18783a96354","solicitation_number":"36C25025Q0419","related_opportunity_id":"d5d703998af145ee95133d1bad209c87"}],"contacts":[{"fax":"Kristina L. Peart","name":"Courtney Seevers","role":"primary","email":"Courtney.Seevers@va.gov","phone":"Contracting Officer","title":"Contract Specialist"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"d5d703998af145ee95133d1bad209c87","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"57b5aa987d1c40c68537e18783a96354","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-18T04:01:00.023724986Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"60db774eae56dc8b1e02c07b86f52fda54ece4f7e5427f3e1c7ed9780e3ff74c","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-18T04:01:00.023724986Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"The Battle Creek VA Medical Center located at 5500 Armstrong Rd, Battle Creek MI 49012 and Wyoming VA Clinic, located at 5838 Metro Way, Wyoming, MI 49519, are soliciting and intends to award a firm-fixed price contract for Sterile Processing Service (SPS) Water and Steam Testing. The Contractor shall provide all labor, equipment, materials, supplies, and supervision to complete testing of the SPS water and steam at Battle Creek VAMC and Wyoming VA Clinic. \nThis procurement has been set-aside 100% for award to Small Business concerns. Offers from other than Small Business concerns will not be considered and shall be rejected. Anticipated award date is May 10, 2025, for a base period of one (1) year plus four (4) one (1) year option periods to be exercised at the discretion of the Government. No telephone requests will be accepted. Solicitation packages will be available on or about April 10, 2025. Electronic solicitations may be obtained at no cost from the following URL: www.SAM.gov. \nAll questions will be answered via Solicitation amendment. Questions must be submitted in writing to the Contract Specialist at the following e-mail address: Courtney.Seevers@va.gov no later than 12:00 p.m. (ET) April 17, 2025.\nQuotations are due no later than 12:00 p.m. (ET) on April 24, 2025, by email  to Courtney.Seevers@va.gov, NAICS 238220 applies. Size standard s $19 Million.","text":"The Battle Creek VA Medical Center located at 5500 Armstrong Rd, Battle Creek MI 49012 and Wyoming VA Clinic, located at 5838 Metro Way, Wyoming, MI 49519, are soliciting and intends to award a firm-fixed price contract for Sterile Processing Service (SPS) Water and Steam Testing. The Contractor shall provide all labor, equipment, materials, supplies, and supervision to complete testing of the SPS water and steam at Battle Creek VAMC and Wyoming VA Clinic.\nThis procurement has been set-aside 100% for award to Small Business concerns. Offers from other than Small Business concerns will not be considered and shall be rejected. Anticipated award date is May 10, 2025, for a base period of one (1) year plus four (4) one (1) year option periods to be exercised at the discretion of the Government. No telephone requests will be accepted. Solicitation packages will be available on or about April 10, 2025. Electronic solicitations may be obtained at no cost from the following URL: www.SAM.gov.\nAll questions will be answered via Solicitation amendment. Questions must be submitted in writing to the Contract Specialist at the following e-mail address: Courtney.Seevers@va.gov no later than 12:00 p.m. (ET) April 17, 2025.\nQuotations are due no later than 12:00 p.m. (ET) on April 24, 2025, by email to Courtney.Seevers@va.gov, NAICS 238220 applies. Size standard s $19 Million.","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"36C25025Q0419","place_of_performance":{"zip":"49012","city":{"name":"Battle Creek"},"state":{"name":"MI"},"street":"Department of Veterans Affairs Battle Creek VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"Attn: Facilities Management Service 5500 Armstrong Rd"},"product_service_code":"H946"},{"award":{"awardee":{}},"dates":{"posted":"2025-04-10","posted_at":"2025-04-10T12:13:19.982Z","created_at":"2025-04-10T12:13:17.781Z","modified_at":"2025-05-24T04:04:31.791Z","response_deadline":{"raw":"2025-04-24T12:00:00-04:00","utc":"2025-04-24T16:00:00Z","date":"2025-04-24","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/57b5aa987d1c40c68537e18783a96354/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","agency":{"office":{"code":"36C250","name":"250-NETWORK CONTRACT OFFICE 10 (36C250)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"organization_id":"100167099","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-05-24","archive_type":"auto_custom"},"history":[{"index":6,"title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-17T20:23:42.469Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d79e95c564bd4ba7939dcb3aed6c633e","solicitation_number":"36C25025Q0419","parent_opportunity_id":"57b5aa987d1c40c68537e18783a96354"},{"index":5,"title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T19:25:21.063Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"d5d703998af145ee95133d1bad209c87","solicitation_number":"36C25025Q0419"},{"index":2,"title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-10T12:13:19.982Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"57b5aa987d1c40c68537e18783a96354","solicitation_number":"36C25025Q0419","related_opportunity_id":"d5d703998af145ee95133d1bad209c87"}],"contacts":[{"name":"Courtney R Seevers","role":"primary","email":"Courtney.Seevers@va.gov","title":"Contract Specialist"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"57b5aa987d1c40c68537e18783a96354","lineage_id":"57b5aa987d1c40c68537e18783a96354","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-18T02:44:01.523764382Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"6be06faa695616505211e8ae6394c6c0b6533e1ac3ed0f3c2a79b046097b3839","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-18T02:44:01.523764382Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Battle Creek Sterile Processing Services (SPS) Water and Steam Testing","text":"Battle Creek Sterile Processing Services (SPS) Water and Steam Testing","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C25025Q0419","product_service_code":"H946"},{"award":{"awardee":{}},"dates":{"posted":"2025-04-17","posted_at":"2025-04-17T20:23:42.469Z","created_at":"2025-04-17T20:23:40.225Z","modified_at":"2025-05-24T04:04:31.791Z","response_deadline":{"raw":"2025-04-24T12:00:00-04:00","utc":"2025-04-24T16:00:00Z","date":"2025-04-24","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/d79e95c564bd4ba7939dcb3aed6c633e/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","agency":{"office":{"code":"36C250","name":"250-NETWORK CONTRACT OFFICE 10 (36C250)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"organization_id":"100167099","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-05-24","archive_type":"auto_custom"},"history":[{"index":6,"title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-05-16T20:18:49.762Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"0d86cd9af21d4d7681ff3837ae9958f8","solicitation_number":"36C25025q0419","related_opportunity_id":"d79e95c564bd4ba7939dcb3aed6c633e"},{"index":4,"title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-17T20:23:42.469Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d79e95c564bd4ba7939dcb3aed6c633e","solicitation_number":"36C25025Q0419","parent_opportunity_id":"57b5aa987d1c40c68537e18783a96354"},{"index":1,"title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-10T12:13:19.982Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"57b5aa987d1c40c68537e18783a96354","solicitation_number":"36C25025Q0419","related_opportunity_id":"d5d703998af145ee95133d1bad209c87"}],"contacts":[{"name":"Courtney R Seevers","role":"primary","email":"Courtney.Seevers@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"d79e95c564bd4ba7939dcb3aed6c633e","lineage_id":"57b5aa987d1c40c68537e18783a96354","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-17T10:10:28.312517306Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"4a68e5a9c228b2030b7ef36a66b00351e0218849a21a4400a7840376621db055","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-17T10:10:28.312517306Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"36C25025Q0419 0001\nPage 2 of 2\n\nContractor Questions\nQuestion 1: Could the NAICS code be changed to 221310 rather than 238220? \nAnswer 1: No, the NIACS shall remain 238220. NAICS 238220 is broadly defined as Plumbing, Heating, and Air-Conditioning Contractors, however it is narrowed to more specific parameters under its corresponding index entries. One of these index entries is water system balancing and testing contractors. As this contract is for water testing, NAICS 238220 was deemed a suitable fit. \n\nQuestion 2: Can FAR 52.219-14 be removed from the solicitation?\nAnswer 2: This solicitation is set-aside for Small Businesses. As prescribed in 19.507(e), FAR 52.219-14(c)(1) is to be inserted in  contracts that have been set aside for any of the small business concerns identified in 19.000(a)(3).  This clause shall not be removed. \n\nQuestion 3: Could the contractor provide a turnaround time of 7-10 business days for sterile processing samples except for bacteria (HPC) and endotoxin which could be provided in 2 business days?\nAnswer 3: We are happy to accept results of any samples prior to the 5 business deadline stated in the SOW\n\nQuestion 4: The SOW Specific Task #7 mentions the creation of a Water management program. What Clin should we include this pricing in? Can a Clin 0005 be included to encapsulate the cost of this development? Additionally, does the VA require program facilitation post Program development.\nAnswer 4: Upon further review, this shall be removed from the SOW. An updated SOW has been attached. \n\n\n\n\n\n\n\n\n\nSOW Title:  Sterile Processing Service (SPS) Water and Steam Testing\nBackground: The Battle Creek VA Medical Center (BCVAMC) is required to complete testing on all water and steam systems utilize in the reprocessing of reusable medical devices. Water impurities can have adverse effects on medical devices and patient outcomes. The requirements of Association for the Advancement of Medical Instrumentation (AAMI) ST108: Water for the Processing of Medical Devices are intended to mitigate the risks associated with water identified to be in improper quality.\nScope: The BCVAMC requires a contract for SPS water and steam testing to meet the criteria of AAMI ST108 Reprocessing of Reusable Medical Equipment and Veterans Health Administration (VHA) Directive 1116(2) Sterile Processing Services at the BCVAMC and Wyoming VA Clinic, located at 5500 Armstrong Rd, Battle Creek, MI and 5838 Metro Way, Wyoming, MI, respectively.  Services shall be in accordance with the terms, conditions, provisions and schedule of the contract.  \nSpecific Tasks for Testing-Deliverable Product:  \nContractor shall provide all labor, materials, equipment, transportation, lodging and supervision necessary to collect appropriate samples and deliver to a lab meeting requirement for processing of AAMI ST108.\nContractor shall provide training to SPS and Engineering personnel on AAMI ST108 requirements and responsibilities within one (1) week of contract award.\nContractor shall be escorted for all sample collection, either Chief of SPS or Water Safety Engineer shall meet with the collector before any samples are collected.\nTester shall be proficient in AAMI ST108 testing methods and procedures. \nContractor shall collect all samples utilizing aseptic technique to prevent contamination; gloves shall be worn, sample container cap shall not be laid down, sample container mouth shall not encounter anything. All sample ports shall be flushed for a minimum of 5 minutes prior to collecting any samples. Samples shall be collected before disinfection of the water treatment system. Sample ports will be treated with a general disinfectant such as alcohol and be completely dry prior to collecting sample. Do not use bleach or other disinfectant solutions on sample ports prior to sample collection. Do not contaminate sample port or sample container while collecting samples. The collection container shall not be made of polypropylene. At least 100 to 300ml of water should be collected per sample.  To prevent bacterial replication samples shall be placed on ice or at 4Â°C until delivered to the laboratory for testing. Results should be provided in five (5) calendar days of them being received by the lab.\nContractor is to provide emergency service for retesting of out of parameter testing and testing five (5) calendar days post disinfection.  \nTesting shall be in alignment with VA and industry standards and guidance, including the  AAMI ST108-2023 Water for the Reprocessing of Medical Devices ii. Association of periOperative Registered Nurses (AORN) Guideline for Cleaning and Care of Surgical Instruments (https://www.aami.org/standards/featured-standards/aami-st108). \nTable 1: AAMI ST108 Utility Water, Critical Water, and Steam Testing\nWater Quality Measurement\nWater Requirements\nTesting Frequency\nTotal Tests Required\nUtility Water\nAAMI ST108 Chemical Analysis1\nSee Table 5-6 AAMI ST108\nQuarterly/As Needed*\n20 Original Samples for Battle Creek/year \n40  Original Samples for Wyoming/year\n12 Retest/year\nCritical Water\nAAMI ST108 Chemical Analysis1\nSee Table 5-6 AAMI ST108\nMonthly/As Needed*\n120 Original Samples for Battle Creek/year \n156 Original Samples for Wyoming/year\n55 Retest/year\nSteam\nAAMI ST108 Chemical Analysis1\nSee Table 5-6 AAMI ST108\nQuarterly/As Needed*\n12 Original Samples for Battle Creek/year \n8  Original Samples for Wyoming/year\n  2 Retest/year\n1:pH, Alkalinity, TOC, Aluminum, Conductivity, Hardness, Copper, Iron, Manganese, Nitrate, Phosphate, Sulfate, Silicate, Chloride & Zinc (See Table 4 AAMI ST108 for required units)\nConduct one Table 2 test on the first of August each year at each location with 1 retest per location if needed.\nTable 2:  Table 2  Categories and performance qualification levels of water quality for medical device processing\nWater Quality Measurement @ 25 Â°C:\nTotal Alkalinity, Bacteria, Endotoxin, Total Organic Carbon (TOC), Color and Turbidity, Ionic Contaminants, Aluminum, Chloride, Conductivity, Copper, Iron, Manganese,  Nitrate, Phosphate, Sulfate, Silicate, Total Hardness, Zinc\n\nPerformance: The Government will document performance in accordance with deliverables. Any report will become a part of the supporting documentation for any contractual action. \nSecurity Requirements: Contractor will not have access to VA Sensitive Information, patient records, or data.\nGeneral Requirements\nAll on-site work shall be coordinated with COR, Chief of SPS, or Water Safety Engineer at least seven (7) days prior to performing services. \nWater testing shall be done during normal business hours 0730-1600 ET Monday through Friday.\nThe contractor shall respond to routine communications within 24 hours on business days and 48 hours on holidays/weekends. \nSituations requiring more frequent analysis and/or special testing, other than the specified requirements, may arise. The contractor shall not perform any extra cost work without written authorization from the contracting officer. \nAny deficiencies or problems noted with VA test results or with the water treatment system test results are to be reported to the COR and SPS as soon as possible but no later than 4 hours after test results are received. The Contractor shall not perform any work outside of the scope of this contract unless they have been issued a separate Purchase Order to cover that work.\nDeliverables\nThe contractor shall provide complete written reports within five (5) business days after each analysis and inspection. \nThe reports shall include all test results, the date of the test, testing parameters, recommendations, and a review with the COR. \nEach report shall highlight the results with a green for pass and red for fail, indicating whether the results pass or fail the parameters specified in AAMI ST108.\nFor any products utilized in the testing process, the following shall be documented on the report: name, ingredients, control range, test procedures, physical state (liquid, powder, etc.), container size, method of delivery, compatibility with present materials being used, catalog data, Material Safety Data Sheets (MSDS) sheets. \nThe reports shall be emailed to the COR. \nGovernment-Furnished Equipment (GFE)/Government-Furnished Information (GFI): The BCVAMC will not furnish parts and/or test equipment for the performance of this contract. It is the responsibility of the contractor to bring the appropriate equipment; and/or supplies necessary to complete the work as required per this contract.\nOther Pertinent Information or Special Considerations: All work shall be performed by personnel qualified to work on the specific equipment. All work performed shall be compliant with AAMI ST108 guidelines and shall be designed to assure that the BCVAMC is providing the best possible water to process reusable medical equipment.\nPlace of Performance: The Department of Veterans Affairs BCVAMC located at 5500 Armstrong Rd, Battle Creek, MI, and Wyoming VA Clinic located at 5838 Metro Way, Wyoming, MI. AAMI ST108 testing shall take place in Sterile Processing department, Sterile Processing Reverse Osmosis mechanical room, and GI Procedures reprocessing area.","text":"36C25025Q0419 0001\nPage 2 of 2\n\nContractor Questions\nQuestion 1: Could the NAICS code be changed to 221310 rather than 238220?\nAnswer 1: No, the NIACS shall remain 238220. NAICS 238220 is broadly defined as Plumbing, Heating, and Air-Conditioning Contractors, however it is narrowed to more specific parameters under its corresponding index entries. One of these index entries is water system balancing and testing contractors. As this contract is for water testing, NAICS 238220 was deemed a suitable fit.\n\nQuestion 2: Can FAR 52.219-14 be removed from the solicitation?\nAnswer 2: This solicitation is set-aside for Small Businesses. As prescribed in 19.507(e), FAR 52.219-14(c)(1) is to be inserted in contracts that have been set aside for any of the small business concerns identified in 19.000(a)(3). This clause shall not be removed.\n\nQuestion 3: Could the contractor provide a turnaround time of 7-10 business days for sterile processing samples except for bacteria (HPC) and endotoxin which could be provided in 2 business days?\nAnswer 3: We are happy to accept results of any samples prior to the 5 business deadline stated in the SOW\n\nQuestion 4: The SOW Specific Task #7 mentions the creation of a Water management program. What Clin should we include this pricing in? Can a Clin 0005 be included to encapsulate the cost of this development? Additionally, does the VA require program facilitation post Program development.\nAnswer 4: Upon further review, this shall be removed from the SOW. An updated SOW has been attached.\n\nSOW Title: Sterile Processing Service (SPS) Water and Steam Testing\nBackground: The Battle Creek VA Medical Center (BCVAMC) is required to complete testing on all water and steam systems utilize in the reprocessing of reusable medical devices. Water impurities can have adverse effects on medical devices and patient outcomes. The requirements of Association for the Advancement of Medical Instrumentation (AAMI) ST108: Water for the Processing of Medical Devices are intended to mitigate the risks associated with water identified to be in improper quality.\nScope: The BCVAMC requires a contract for SPS water and steam testing to meet the criteria of AAMI ST108 Reprocessing of Reusable Medical Equipment and Veterans Health Administration (VHA) Directive 1116(2) Sterile Processing Services at the BCVAMC and Wyoming VA Clinic, located at 5500 Armstrong Rd, Battle Creek, MI and 5838 Metro Way, Wyoming, MI, respectively. Services shall be in accordance with the terms, conditions, provisions and schedule of the contract.\nSpecific Tasks for Testing-Deliverable Product:\nContractor shall provide all labor, materials, equipment, transportation, lodging and supervision necessary to collect appropriate samples and deliver to a lab meeting requirement for processing of AAMI ST108.\nContractor shall provide training to SPS and Engineering personnel on AAMI ST108 requirements and responsibilities within one (1) week of contract award.\nContractor shall be escorted for all sample collection, either Chief of SPS or Water Safety Engineer shall meet with the collector before any samples are collected.\nTester shall be proficient in AAMI ST108 testing methods and procedures.\nContractor shall collect all samples utilizing aseptic technique to prevent contamination; gloves shall be worn, sample container cap shall not be laid down, sample container mouth shall not encounter anything. All sample ports shall be flushed for a minimum of 5 minutes prior to collecting any samples. Samples shall be collected before disinfection of the water treatment system. Sample ports will be treated with a general disinfectant such as alcohol and be completely dry prior to collecting sample. Do not use bleach or other disinfectant solutions on sample ports prior to sample collection. Do not contaminate sample port or sample container while collecting samples. The collection container shall not be made of polypropylene. At least 100 to 300ml of water should be collected per sample. To prevent bacterial replication samples shall be placed on ice or at 4Â°C until delivered to the laboratory for testing. Results should be provided in five (5) calendar days of them being received by the lab.\nContractor is to provide emergency service for retesting of out of parameter testing and testing five (5) calendar days post disinfection.\nTesting shall be in alignment with VA and industry standards and guidance, including the AAMI ST108-2023 Water for the Reprocessing of Medical Devices ii. Association of periOperative Registered Nurses (AORN) Guideline for Cleaning and Care of Surgical Instruments (https://www.aami.org/standards/featured-standards/aami-st108).\nTable 1: AAMI ST108 Utility Water, Critical Water, and Steam Testing\nWater Quality Measurement\nWater Requirements\nTesting Frequency\nTotal Tests Required\nUtility Water\nAAMI ST108 Chemical Analysis1\nSee Table 5-6 AAMI ST108\nQuarterly/As Needed*\n20 Original Samples for Battle Creek/year\n40 Original Samples for Wyoming/year\n12 Retest/year\nCritical Water\nAAMI ST108 Chemical Analysis1\nSee Table 5-6 AAMI ST108\nMonthly/As Needed*\n120 Original Samples for Battle Creek/year\n156 Original Samples for Wyoming/year\n55 Retest/year\nSteam\nAAMI ST108 Chemical Analysis1\nSee Table 5-6 AAMI ST108\nQuarterly/As Needed*\n12 Original Samples for Battle Creek/year\n8 Original Samples for Wyoming/year\n2 Retest/year\n1:pH, Alkalinity, TOC, Aluminum, Conductivity, Hardness, Copper, Iron, Manganese, Nitrate, Phosphate, Sulfate, Silicate, Chloride & Zinc (See Table 4 AAMI ST108 for required units)\nConduct one Table 2 test on the first of August each year at each location with 1 retest per location if needed.\nTable 2: Table 2 Categories and performance qualification levels of water quality for medical device processing\nWater Quality Measurement @ 25 Â°C:\nTotal Alkalinity, Bacteria, Endotoxin, Total Organic Carbon (TOC), Color and Turbidity, Ionic Contaminants, Aluminum, Chloride, Conductivity, Copper, Iron, Manganese, Nitrate, Phosphate, Sulfate, Silicate, Total Hardness, Zinc\n\nPerformance: The Government will document performance in accordance with deliverables. Any report will become a part of the supporting documentation for any contractual action.\nSecurity Requirements: Contractor will not have access to VA Sensitive Information, patient records, or data.\nGeneral Requirements\nAll on-site work shall be coordinated with COR, Chief of SPS, or Water Safety Engineer at least seven (7) days prior to performing services.\nWater testing shall be done during normal business hours 0730-1600 ET Monday through Friday.\nThe contractor shall respond to routine communications within 24 hours on business days and 48 hours on holidays/weekends.\nSituations requiring more frequent analysis and/or special testing, other than the specified requirements, may arise. The contractor shall not perform any extra cost work without written authorization from the contracting officer.\nAny deficiencies or problems noted with VA test results or with the water treatment system test results are to be reported to the COR and SPS as soon as possible but no later than 4 hours after test results are received. The Contractor shall not perform any work outside of the scope of this contract unless they have been issued a separate Purchase Order to cover that work.\nDeliverables\nThe contractor shall provide complete written reports within five (5) business days after each analysis and inspection.\nThe reports shall include all test results, the date of the test, testing parameters, recommendations, and a review with the COR.\nEach report shall highlight the results with a green for pass and red for fail, indicating whether the results pass or fail the parameters specified in AAMI ST108.\nFor any products utilized in the testing process, the following shall be documented on the report: name, ingredients, control range, test procedures, physical state (liquid, powder, etc.), container size, method of delivery, compatibility with present materials being used, catalog data, Material Safety Data Sheets (MSDS) sheets.\nThe reports shall be emailed to the COR.\nGovernment-Furnished Equipment (GFE)/Government-Furnished Information (GFI): The BCVAMC will not furnish parts and/or test equipment for the performance of this contract. It is the responsibility of the contractor to bring the appropriate equipment; and/or supplies necessary to complete the work as required per this contract.\nOther Pertinent Information or Special Considerations: All work shall be performed by personnel qualified to work on the specific equipment. All work performed shall be compliant with AAMI ST108 guidelines and shall be designed to assure that the BCVAMC is providing the best possible water to process reusable medical equipment.\nPlace of Performance: The Department of Veterans Affairs BCVAMC located at 5500 Armstrong Rd, Battle Creek, MI, and Wyoming VA Clinic located at 5838 Metro Way, Wyoming, MI. AAMI ST108 testing shall take place in Sterile Processing department, Sterile Processing Reverse Osmosis mechanical room, and GI Procedures reprocessing area.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C25025Q0419","product_service_code":"H946"},{"award":{"date":"2025-05-16","amount":"600523.00","number":"36C25025C0105","awardee":{"raw":"RLM GOVERNMENT SERVICES LLC WASHINGTON 20010","uei":"XALLUMS81NY6","cage":"8G6D5","name":"RLM GOVERNMENT SERVICES LLC","location":{"zip":"20010","city":{"name":"WASHINGTON"},"state":{"name":"DC"},"country":{"name":"DC"}}}},"dates":{"posted":"2025-05-16","posted_at":"2025-05-16T20:18:49.762Z","award_date":"2025-05-16","created_at":"2025-05-16T20:18:48.589Z","modified_at":"2025-06-16T03:55:47.048Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/0d86cd9af21d4d7681ff3837ae9958f8/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","agency":{"office":{"code":"36C250","name":"250-NETWORK CONTRACT OFFICE 10 (36C250)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"organization_id":"100167099","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-06-15","archive_type":"auto_custom"},"history":[{"index":5,"title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-05-16T20:18:49.762Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"0d86cd9af21d4d7681ff3837ae9958f8","solicitation_number":"36C25025q0419","related_opportunity_id":"d79e95c564bd4ba7939dcb3aed6c633e"},{"index":3,"title":"H946--Sterile Processing Service (SPS) Testing Water/Steam for Battle Creek and Wyoming","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-17T20:23:42.469Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d79e95c564bd4ba7939dcb3aed6c633e","solicitation_number":"36C25025Q0419","parent_opportunity_id":"57b5aa987d1c40c68537e18783a96354"}],"contacts":[{"fax":"Kristina L. Peart","name":"Courtney Seevers","role":"primary","email":"Courtney.Seevers@va.gov","phone":"Contracting Officer","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"0d86cd9af21d4d7681ff3837ae9958f8","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"57b5aa987d1c40c68537e18783a96354","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-15T01:41:27.996706631Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"10eabc96e9866fbd9d23a401b8949e7332366cd4a7353dc69589445c526c64d8","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-15T01:41:27.996706631Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"36C25025q0419","product_service_code":"H946"}],"due_at":"2025-04-24T16:00:00Z","due_date":"2025-04-24","closes_at":"2025-04-24T16:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","state":"MI","county":"26077","county_name":"Kalamazoo County","city":null,"city_name":null,"country":"USA","state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":"XALLUMS81NY6","amount":"600523.00","linked_awards":4,"cancelled":false,"archived":true,"updated_at":"2026-11-15T01:59:45.987768Z","principal_notice_id":"d79e95c564bd4ba7939dcb3aed6c633e","description":{"text":"36C25025Q0419 0001\nPage 2 of 2\n\nContractor Questions\nQuestion 1: Could the NAICS code be changed to 221310 rather than 238220?\nAnswer 1: No, the NIACS shall remain 238220. NAICS 238220 is broadly defined as Plumbing, Heating, and Air-Conditioning Contractors, however it is narrowed to more specific parameters under its corresponding index entries. One of these index entries is water system balancing and testing contractors. As this contract is for water testing, NAICS 238220 was deemed a suitable fit.\n\nQuestion 2: Can FAR 52.219-14 be removed from the solicitation?\nAnswer 2: This solicitation is set-aside for Small Businesses. As prescribed in 19.507(e), FAR 52.219-14(c)(1) is to be inserted in contracts that have been set aside for any of the small business concerns identified in 19.000(a)(3). This clause shall not be removed.\n\nQuestion 3: Could the contractor provide a turnaround time of 7-10 business days for sterile processing samples except for bacteria (HPC) and endotoxin which could be provided in 2 business days?\nAnswer 3: We are happy to accept results of any samples prior to the 5 business deadline stated in the SOW\n\nQuestion 4: The SOW Specific Task #7 mentions the creation of a Water management program. What Clin should we include this pricing in? Can a Clin 0005 be included to encapsulate the cost of this development? Additionally, does the VA require program facilitation post Program development.\nAnswer 4: Upon further review, this shall be removed from the SOW. An updated SOW has been attached.\n\nSOW Title: Sterile Processing Service (SPS) Water and Steam Testing\nBackground: The Battle Creek VA Medical Center (BCVAMC) is required to complete testing on all water and steam systems utilize in the reprocessing of reusable medical devices. Water impurities can have adverse effects on medical devices and patient outcomes. The requirements of Association for the Advancement of Medical Instrumentation (AAMI) ST108: Water for the Processing of Medical Devices are intended to mitigate the risks associated with water identified to be in improper quality.\nScope: The BCVAMC requires a contract for SPS water and steam testing to meet the criteria of AAMI ST108 Reprocessing of Reusable Medical Equipment and Veterans Health Administration (VHA) Directive 1116(2) Sterile Processing Services at the BCVAMC and Wyoming VA Clinic, located at 5500 Armstrong Rd, Battle Creek, MI and 5838 Metro Way, Wyoming, MI, respectively. Services shall be in accordance with the terms, conditions, provisions and schedule of the contract.\nSpecific Tasks for Testing-Deliverable Product:\nContractor shall provide all labor, materials, equipment, transportation, lodging and supervision necessary to collect appropriate samples and deliver to a lab meeting requirement for processing of AAMI ST108.\nContractor shall provide training to SPS and Engineering personnel on AAMI ST108 requirements and responsibilities within one (1) week of contract award.\nContractor shall be escorted for all sample collection, either Chief of SPS or Water Safety Engineer shall meet with the collector before any samples are collected.\nTester shall be proficient in AAMI ST108 testing methods and procedures.\nContractor shall collect all samples utilizing aseptic technique to prevent contamination; gloves shall be worn, sample container cap shall not be laid down, sample container mouth shall not encounter anything. All sample ports shall be flushed for a minimum of 5 minutes prior to collecting any samples. Samples shall be collected before disinfection of the water treatment system. Sample ports will be treated with a general disinfectant such as alcohol and be completely dry prior to collecting sample. Do not use bleach or other disinfectant solutions on sample ports prior to sample collection. Do not contaminate sample port or sample container while collecting samples. The collection container shall not be made of polypropylene. At least 100 to 300ml of water should be collected per sample. To prevent bacterial replication samples shall be placed on ice or at 4Â°C until delivered to the laboratory for testing. Results should be provided in five (5) calendar days of them being received by the lab.\nContractor is to provide emergency service for retesting of out of parameter testing and testing five (5) calendar days post disinfection.\nTesting shall be in alignment with VA and industry standards and guidance, including the AAMI ST108-2023 Water for the Reprocessing of Medical Devices ii. Association of periOperative Registered Nurses (AORN) Guideline for Cleaning and Care of Surgical Instruments (https://www.aami.org/standards/featured-standards/aami-st108).\nTable 1: AAMI ST108 Utility Water, Critical Water, and Steam Testing\nWater Quality Measurement\nWater Requirements\nTesting Frequency\nTotal Tests Required\nUtility Water\nAAMI ST108 Chemical Analysis1\nSee Table 5-6 AAMI ST108\nQuarterly/As Needed*\n20 Original Samples for Battle Creek/year\n40 Original Samples for Wyoming/year\n12 Retest/year\nCritical Water\nAAMI ST108 Chemical Analysis1\nSee Table 5-6 AAMI ST108\nMonthly/As Needed*\n120 Original Samples for Battle Creek/year\n156 Original Samples for Wyoming/year\n55 Retest/year\nSteam\nAAMI ST108 Chemical Analysis1\nSee Table 5-6 AAMI ST108\nQuarterly/As Needed*\n12 Original Samples for Battle Creek/year\n8 Original Samples for Wyoming/year\n2 Retest/year\n1:pH, Alkalinity, TOC, Aluminum, Conductivity, Hardness, Copper, Iron, Manganese, Nitrate, Phosphate, Sulfate, Silicate, Chloride & Zinc (See Table 4 AAMI ST108 for required units)\nConduct one Table 2 test on the first of August each year at each location with 1 retest per location if needed.\nTable 2: Table 2 Categories and performance qualification levels of water quality for medical device processing\nWater Quality Measurement @ 25 Â°C:\nTotal Alkalinity, Bacteria, Endotoxin, Total Organic Carbon (TOC), Color and Turbidity, Ionic Contaminants, Aluminum, Chloride, Conductivity, Copper, Iron, Manganese, Nitrate, Phosphate, Sulfate, Silicate, Total Hardness, Zinc\n\nPerformance: The Government will document performance in accordance with deliverables. Any report will become a part of the supporting documentation for any contractual action.\nSecurity Requirements: Contractor will not have access to VA Sensitive Information, patient records, or data.\nGeneral Requirements\nAll on-site work shall be coordinated with COR, Chief of SPS, or Water Safety Engineer at least seven (7) days prior to performing services.\nWater testing shall be done during normal business hours 0730-1600 ET Monday through Friday.\nThe contractor shall respond to routine communications within 24 hours on business days and 48 hours on holidays/weekends.\nSituations requiring more frequent analysis and/or special testing, other than the specified requirements, may arise. The contractor shall not perform any extra cost work without written authorization from the contracting officer.\nAny deficiencies or problems noted with VA test results or with the water treatment system test results are to be reported to the COR and SPS as soon as possible but no later than 4 hours after test results are received. The Contractor shall not perform any work outside of the scope of this contract unless they have been issued a separate Purchase Order to cover that work.\nDeliverables\nThe contractor shall provide complete written reports within five (5) business days after each analysis and inspection.\nThe reports shall include all test results, the date of the test, testing parameters, recommendations, and a review with the COR.\nEach report shall highlight the results with a green for pass and red for fail, indicating whether the results pass or fail the parameters specified in AAMI ST108.\nFor any products utilized in the testing process, the following shall be documented on the report: name, ingredients, control range, test procedures, physical state (liquid, powder, etc.), container size, method of delivery, compatibility with present materials being used, catalog data, Material Safety Data Sheets (MSDS) sheets.\nThe reports shall be emailed to the COR.\nGovernment-Furnished Equipment (GFE)/Government-Furnished Information (GFI): The BCVAMC will not furnish parts and/or test equipment for the performance of this contract. It is the responsibility of the contractor to bring the appropriate equipment; and/or supplies necessary to complete the work as required per this contract.\nOther Pertinent Information or Special Considerations: All work shall be performed by personnel qualified to work on the specific equipment. All work performed shall be compliant with AAMI ST108 guidelines and shall be designed to assure that the BCVAMC is providing the best possible water to process reusable medical equipment.\nPlace of Performance: The Department of Veterans Affairs BCVAMC located at 5500 Armstrong Rd, Battle Creek, MI, and Wyoming VA Clinic located at 5838 Metro Way, Wyoming, MI. AAMI ST108 testing shall take place in Sterile Processing department, Sterile Processing Reverse Osmosis mechanical room, and GI Procedures reprocessing area.","html":"36C25025Q0419 0001\nPage 2 of 2\n\nContractor Questions\nQuestion 1: Could the NAICS code be changed to 221310 rather than 238220? \nAnswer 1: No, the NIACS shall remain 238220. NAICS 238220 is broadly defined as Plumbing, Heating, and Air-Conditioning Contractors, however it is narrowed to more specific parameters under its corresponding index entries. One of these index entries is water system balancing and testing contractors. As this contract is for water testing, NAICS 238220 was deemed a suitable fit. \n\nQuestion 2: Can FAR 52.219-14 be removed from the solicitation?\nAnswer 2: This solicitation is set-aside for Small Businesses. As prescribed in 19.507(e), FAR 52.219-14(c)(1) is to be inserted in  contracts that have been set aside for any of the small business concerns identified in 19.000(a)(3).  This clause shall not be removed. \n\nQuestion 3: Could the contractor provide a turnaround time of 7-10 business days for sterile processing samples except for bacteria (HPC) and endotoxin which could be provided in 2 business days?\nAnswer 3: We are happy to accept results of any samples prior to the 5 business deadline stated in the SOW\n\nQuestion 4: The SOW Specific Task #7 mentions the creation of a Water management program. What Clin should we include this pricing in? Can a Clin 0005 be included to encapsulate the cost of this development? Additionally, does the VA require program facilitation post Program development.\nAnswer 4: Upon further review, this shall be removed from the SOW. An updated SOW has been attached. \n\n\n\n\n\n\n\n\n\nSOW Title:  Sterile Processing Service (SPS) Water and Steam Testing\nBackground: The Battle Creek VA Medical Center (BCVAMC) is required to complete testing on all water and steam systems utilize in the reprocessing of reusable medical devices. Water impurities can have adverse effects on medical devices and patient outcomes. The requirements of Association for the Advancement of Medical Instrumentation (AAMI) ST108: Water for the Processing of Medical Devices are intended to mitigate the risks associated with water identified to be in improper quality.\nScope: The BCVAMC requires a contract for SPS water and steam testing to meet the criteria of AAMI ST108 Reprocessing of Reusable Medical Equipment and Veterans Health Administration (VHA) Directive 1116(2) Sterile Processing Services at the BCVAMC and Wyoming VA Clinic, located at 5500 Armstrong Rd, Battle Creek, MI and 5838 Metro Way, Wyoming, MI, respectively.  Services shall be in accordance with the terms, conditions, provisions and schedule of the contract.  \nSpecific Tasks for Testing-Deliverable Product:  \nContractor shall provide all labor, materials, equipment, transportation, lodging and supervision necessary to collect appropriate samples and deliver to a lab meeting requirement for processing of AAMI ST108.\nContractor shall provide training to SPS and Engineering personnel on AAMI ST108 requirements and responsibilities within one (1) week of contract award.\nContractor shall be escorted for all sample collection, either Chief of SPS or Water Safety Engineer shall meet with the collector before any samples are collected.\nTester shall be proficient in AAMI ST108 testing methods and procedures. \nContractor shall collect all samples utilizing aseptic technique to prevent contamination; gloves shall be worn, sample container cap shall not be laid down, sample container mouth shall not encounter anything. All sample ports shall be flushed for a minimum of 5 minutes prior to collecting any samples. Samples shall be collected before disinfection of the water treatment system. Sample ports will be treated with a general disinfectant such as alcohol and be completely dry prior to collecting sample. Do not use bleach or other disinfectant solutions on sample ports prior to sample collection. Do not contaminate sample port or sample container while collecting samples. The collection container shall not be made of polypropylene. At least 100 to 300ml of water should be collected per sample.  To prevent bacterial replication samples shall be placed on ice or at 4Â°C until delivered to the laboratory for testing. Results should be provided in five (5) calendar days of them being received by the lab.\nContractor is to provide emergency service for retesting of out of parameter testing and testing five (5) calendar days post disinfection.  \nTesting shall be in alignment with VA and industry standards and guidance, including the  AAMI ST108-2023 Water for the Reprocessing of Medical Devices ii. Association of periOperative Registered Nurses (AORN) Guideline for Cleaning and Care of Surgical Instruments (https://www.aami.org/standards/featured-standards/aami-st108). \nTable 1: AAMI ST108 Utility Water, Critical Water, and Steam Testing\nWater Quality Measurement\nWater Requirements\nTesting Frequency\nTotal Tests Required\nUtility Water\nAAMI ST108 Chemical Analysis1\nSee Table 5-6 AAMI ST108\nQuarterly/As Needed*\n20 Original Samples for Battle Creek/year \n40  Original Samples for Wyoming/year\n12 Retest/year\nCritical Water\nAAMI ST108 Chemical Analysis1\nSee Table 5-6 AAMI ST108\nMonthly/As Needed*\n120 Original Samples for Battle Creek/year \n156 Original Samples for Wyoming/year\n55 Retest/year\nSteam\nAAMI ST108 Chemical Analysis1\nSee Table 5-6 AAMI ST108\nQuarterly/As Needed*\n12 Original Samples for Battle Creek/year \n8  Original Samples for Wyoming/year\n  2 Retest/year\n1:pH, Alkalinity, TOC, Aluminum, Conductivity, Hardness, Copper, Iron, Manganese, Nitrate, Phosphate, Sulfate, Silicate, Chloride & Zinc (See Table 4 AAMI ST108 for required units)\nConduct one Table 2 test on the first of August each year at each location with 1 retest per location if needed.\nTable 2:  Table 2  Categories and performance qualification levels of water quality for medical device processing\nWater Quality Measurement @ 25 Â°C:\nTotal Alkalinity, Bacteria, Endotoxin, Total Organic Carbon (TOC), Color and Turbidity, Ionic Contaminants, Aluminum, Chloride, Conductivity, Copper, Iron, Manganese,  Nitrate, Phosphate, Sulfate, Silicate, Total Hardness, Zinc\n\nPerformance: The Government will document performance in accordance with deliverables. Any report will become a part of the supporting documentation for any contractual action. \nSecurity Requirements: Contractor will not have access to VA Sensitive Information, patient records, or data.\nGeneral Requirements\nAll on-site work shall be coordinated with COR, Chief of SPS, or Water Safety Engineer at least seven (7) days prior to performing services. \nWater testing shall be done during normal business hours 0730-1600 ET Monday through Friday.\nThe contractor shall respond to routine communications within 24 hours on business days and 48 hours on holidays/weekends. \nSituations requiring more frequent analysis and/or special testing, other than the specified requirements, may arise. The contractor shall not perform any extra cost work without written authorization from the contracting officer. \nAny deficiencies or problems noted with VA test results or with the water treatment system test results are to be reported to the COR and SPS as soon as possible but no later than 4 hours after test results are received. The Contractor shall not perform any work outside of the scope of this contract unless they have been issued a separate Purchase Order to cover that work.\nDeliverables\nThe contractor shall provide complete written reports within five (5) business days after each analysis and inspection. \nThe reports shall include all test results, the date of the test, testing parameters, recommendations, and a review with the COR. \nEach report shall highlight the results with a green for pass and red for fail, indicating whether the results pass or fail the parameters specified in AAMI ST108.\nFor any products utilized in the testing process, the following shall be documented on the report: name, ingredients, control range, test procedures, physical state (liquid, powder, etc.), container size, method of delivery, compatibility with present materials being used, catalog data, Material Safety Data Sheets (MSDS) sheets. \nThe reports shall be emailed to the COR. \nGovernment-Furnished Equipment (GFE)/Government-Furnished Information (GFI): The BCVAMC will not furnish parts and/or test equipment for the performance of this contract. It is the responsibility of the contractor to bring the appropriate equipment; and/or supplies necessary to complete the work as required per this contract.\nOther Pertinent Information or Special Considerations: All work shall be performed by personnel qualified to work on the specific equipment. All work performed shall be compliant with AAMI ST108 guidelines and shall be designed to assure that the BCVAMC is providing the best possible water to process reusable medical equipment.\nPlace of Performance: The Department of Veterans Affairs BCVAMC located at 5500 Armstrong Rd, Battle Creek, MI, and Wyoming VA Clinic located at 5838 Metro Way, Wyoming, MI. AAMI ST108 testing shall take place in Sterile Processing department, Sterile Processing Reverse Osmosis mechanical room, and GI Procedures reprocessing area.","origin":"detail"},"contacts":[{"fax":"Kristina L. Peart","name":"Courtney Seevers","role":"primary","email":"Courtney.Seevers@va.gov","phone":"Contracting Officer","title":"Contract Specialist"}],"place_of_performance":null,"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"naics_codes":["238220"],"award":{"awardee":{}},"attachments":[{"resource_id":"a676482f6e55478ab7e9f911f3f9570d","name":"36C25025C0105_1.docx","kind":"file","mime_type":".docx","size_bytes":22132,"posted_at":"2025-05-16T20:18:49.762Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/a676482f6e55478ab7e9f911f3f9570d/download","mirrored":false},{"resource_id":"1381853bf871430aa910c1c7e029e01c","name":"36C25025Q0419.docx","kind":"file","mime_type":".docx","size_bytes":138687,"posted_at":"2025-04-10T12:13:19.982Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/1381853bf871430aa910c1c7e029e01c/download","mirrored":false},{"resource_id":"9d5912413a8049f690a8c07a1afb0303","name":"36C25025Q0419_1.docx","kind":"file","mime_type":".docx","size_bytes":23657,"posted_at":"2025-04-09T19:25:21.063Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/9d5912413a8049f690a8c07a1afb0303/download","mirrored":false},{"resource_id":"9c79b92063d04391b8d2c51a9e401a7b","name":"36C25025Q0419 0001.docx","kind":"file","mime_type":".docx","size_bytes":36959,"posted_at":"2025-04-17T20:23:42.469Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/9c79b92063d04391b8d2c51a9e401a7b/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C25025C0105_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C25025C0105_3600_-NONE-_-NONE-/","piid":"36C25025C0105","parent_piid":null,"award_type":"DEFINITIVE CONTRACT","vendor_key":"XALLUMS81NY6","recipient_name":"RLM GOVERNMENT SERVICES LLC","recipient_uei":"XALLUMS81NY6","recipient_cage":"8G6D5","recipient_city":"WASHINGTON","recipient_state":"DC","sub_name":"Department of Veterans Affairs","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","office_key":"o-36C250","first_action_date":"2025-05-16","last_action_date":"2026-09-11","actions":5,"obligated":"202445.00","current_total_value":"202445.00","potential_total_value":"573310.00","naics":"238220","psc":"H946","extent_competed":"COMPETED UNDER SAP","set_aside":"SMALL BUSINESS SET ASIDE - TOTAL","offers_received":4,"description":"BATTLE CREEK STERILE PROCESSING SERVICES WATER AND STEAM TESTING - BASE YEAR","method":"piid","confidence":"high","evidence":["award number 36C25025C0105 equals the contract number","same awarding office 36C250"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C25027Q0113","latest_notice_id":"30f6d444e0f641e5b23d5b4c1ec5a384","title":"Q301--Prostate Reference Lab Testing Services","solicitation_number":"36C25027Q0113","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-25T21:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"621511","psc":"Q301","set_aside":null,"state":"OH","county":"39049","county_name":"Franklin County","city":"3918000","city_name":"Columbus","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C25027Q0014","latest_notice_id":"b13cc87179e947e7b42da2de44a6bde1","title":"J061--541 Electrical Power Distribution Equipment Testing, Inspection, and Maintenance - VAMC Cleveland","solicitation_number":"36C25027Q0014","notice_type":"k","first_type":"k","first_posted":"2026-10-09","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"238210","psc":"J061","set_aside":"SBA","state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C25027Q0123","latest_notice_id":"fb53a332644a4c8fa983bf28c8643d2d","title":"S222--Sources Sought - Hazardous Waste Removal/Disposal Northeast Ohio VA Healthcare System - Cleveland, OH","solicitation_number":"36C25027Q0123","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T18:30:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"562112","psc":"S222","set_aside":null,"state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C25027B0009","latest_notice_id":"85b83d408f1f422885991142c2734b45","title":"Z1DA--FY27 NRM - VISN Base Modernize Nurse Call - 539-23-101","solicitation_number":"36C25027B0009","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"},{"key":"36C25027B0008","latest_notice_id":"5afe716a38494a6f84b1e84205805f86","title":"Z1DA--FY27 NRM - VISN Base Install Roof Equipment Railings - 539-22-206","solicitation_number":"36C25027B0008","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"}],"similar_open":[{"key":"W911PT27QA020","latest_notice_id":"084d5efc5ec44a9885a37b90e6705ffa","title":"REMOVE AND REPAIR TWO HIGH VELOCITY AIR HANDLING UNITS","solicitation_number":"W911PT27QA020","notice_type":"k","first_type":"k","first_posted":"2026-11-05","last_posted":"2026-11-05","notices":1,"due_at":"2026-11-25T18:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911PT","office_name":"W6QK ACC WVA","naics":"238220","psc":"Z2NB","set_aside":"SBA","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"IGH VELOCITY AIR HANDLING UNITSPROJECT LOCATION: WATERVLIET ARSENAL","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-06T04:46:59.158685Z"},{"key":"2031ZA27B00001","latest_notice_id":"622efd27a6cf48589063c08d3700b96b","title":"Modernize Regenerative Thermal Oxidizer (RTO)","solicitation_number":"2031ZA27B00001","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-25T21:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-020","dept_name":"TREASURY, DEPARTMENT OF THE","sub_key":"s-2041","sub_name":"BUREAU OF ENGRAVING AND PRINTING","office_key":"o-2031ZA","office_name":"OFFICE OF THE CHIEF PROCUREMENT OFFICER","naics":"238220","psc":"Z2AZ","set_aside":null,"state":"TX","county":"48439","county_name":"Tarrant County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"140PP027B0004","latest_notice_id":"53398cb59b8f4b0687efd4e3fa6241dc","title":"Z--13976 PUHO FIRE PROTECTION AT DORM","solicitation_number":"140PP027B0004","notice_type":"r","first_type":"s","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":2,"due_at":"2026-11-26T03:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-26T03:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-014","dept_name":"INTERIOR, DEPARTMENT OF THE","sub_key":"s-1406","sub_name":"DEPARTMENTAL OFFICES","office_key":"o-140PP0","office_name":"NATIONAL PARK SERVICE CONTRACTING ACTIVITY","naics":"238220","psc":"Z2AA","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open_total":59,"indexable":false}