{"canonical":"https://sealedbidder.com/opportunities/36c25025q0299","key":"36C25025Q0299","url":"https://sealedbidder.com/opportunities/36c25025q0299","title":"6515--Guldmann (Or Equivalent) Patient Ceiling Lifts","solicitation_number":"36C25025Q0299","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-02-21T22:00:00Z","first_posted":"2025-02-13","last_posted":"2025-02-13","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"339113","psc":"6515","set_aside":null,"place_state":"MI","place_scope":"nationwide","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"26145","place_county_name":"Saginaw County","place_city":"2670520","place_city_name":"Saginaw","winner":null,"award_amount":null,"publications":[{"notice_id":"6c7d92cbfc944078adaeee24415c3df3","title":"6515--Guldmann (Or Equivalent) Patient Ceiling Lifts","solicitation_number":"36C25025Q0299","notice_type":"r","base_type":"r","posted":"2025-02-13","posted_at":"2025-02-13T16:43:25.185Z","due_at":"2025-02-21T22:00:00Z","due_date":"2025-02-21","cancelled":false,"archived":true,"archive_date":"2025-04-22","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/6c7d92cbfc944078adaeee24415c3df3/view","enriched":true,"history":[{"index":3,"title":"6515--Guldmann (Or Equivalent) Patient Ceiling Lifts","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-13T16:43:25.185Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"6c7d92cbfc944078adaeee24415c3df3","solicitation_number":"36C25025Q0299"}]}],"latest_notice_id":"6c7d92cbfc944078adaeee24415c3df3","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-02-13","posted_at":"2025-02-13T16:43:25.185Z","created_at":"2025-02-13T16:43:22.991Z","modified_at":"2025-04-23T03:55:57.701Z","response_deadline":{"raw":"2025-02-21T17:00:00-05:00","utc":"2025-02-21T22:00:00Z","date":"2025-02-21","time":"17:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/6c7d92cbfc944078adaeee24415c3df3/view"},"naics":{"codes":["339113"],"primary":"339113"},"title":"6515--Guldmann (Or Equivalent) Patient Ceiling Lifts","agency":{"office":{"code":"36C250","name":"250-NETWORK CONTRACT OFFICE 10 (36C250)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"organization_id":"100167099","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-04-22","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--Guldmann (Or Equivalent) Patient Ceiling Lifts","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-13T16:43:25.185Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"6c7d92cbfc944078adaeee24415c3df3","solicitation_number":"36C25025Q0299"}],"contacts":[{"name":"Jeffrey Rozema","role":"primary","email":"jeffrey.rozema@va.gov","phone":"269-966-5600 x36450","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"6c7d92cbfc944078adaeee24415c3df3","lineage_id":"6c7d92cbfc944078adaeee24415c3df3","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-22T10:30:47.745772588Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"82517084abe9be3d8c2adb2fc9cf00bca28c9511fc207fcfbbf3e609ef901d55","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-22T10:30:47.745772588Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"This is a SOURCES SOUGHT request for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time.  \nThis notice is intended strictly for market research.  The purpose of this Sources Sought notice is to determine the interest and capability of any contractor to meet the requirements listed below, with an emphasis on service-disabled veteran owned small business, veteran owned small business, and other small business.  \nThe Department of Veterans Affairs, Regional Procurement Office Central, Network Contracting Office 10 is seeking sources for Guldmann (or equivalent) patient ceiling lifts for the Aleda E. Lutz VA Medical Center located at 1500 Weiss Street, Saginaw, MI 48602. The patient ceiling lifts will be installed in the Saginaw VA s Morgue, Nuclear Medicine, Surgery, and Therapy Gyms. The Guldmann lift systems include the following:\n4x4 Room Covering System GH3+ 605 lbs. SWL. w/Scale and Hanger Bar (Includes 1 Mobilization and Tear Out), 1 Each\nStraight Track System GH3+ 605 lbs. SWL. w/Scale includes Hanger Bar, 1 Each\n4x4 Room Covering System GH3+ 605 lbs. SWL. w/Scale and Hanger Bar (Includes 1 Mobilization and Tear Out), 1 Each\nRoom Covering System GH3+ 605 lbs. SWL. w/Trainer Module, Positioning Lock System and Hanger Bar. (Includes 1 mobilization and tear out), 1 Each\nRoom Covering System into Straight Rail GH3+ 605 lbs. SWL. w/Trainer Module and and Hanger Bar. (Includes 1 mobilization and tear out), 1 Each\n3G Porgram-10 Year Annual Inspection/Preventative Maintenance and Extended Parts and Labor Warranty, 5 Each\nDesign/drafting and installation services are also required.\nLift systems must meet the following characteristics/specifications:\nThere must be a lift offered from the manufacturer that can lift at least 600lbs. \nThe transfer gate must be able to support at least 600lbs. \nThe Morgue, Nuclear Medicine, and Surgery rooms must have a X-Y track system (room covering track system) in which the motor is mounted on a perpendicular moving rail that is attached to two parallel recessed fixed rails allowing the lift to travel in four directions (side-to-side and front-to-back).\nTherapy Gym Room 1400-22 must have a X-Y track system in which the motor is mounted on a perpendicular moving rail that is attached to two parallel recessed fixed rails allowing the lift to travel in four directions (side-to-side and front-to-back).  \nThe lifts must have a recessed room covering system. The positioning lock system will be needed on the system in Therapy Gym Room 1400-22. A transfer gait will be needed on the system in Therapy Gym Room B600-22 to transfer the Veteran from the room covering system to the straight rail.\nThe track rails must be capable of accommodating stationary lock for lift unit and/or stationary lock for Traverse Rail with user capability via hand control to separately position and lock the motor and/or the traverse rail in designated location(s) when indicated for patient care activity. \nThe hand control must be wired, with LCD screen capable of displaying patient weight and lift usage information for enable staff to easily read the patient s weight.\nScale must be internal to maximize hanger bar height and thus lift functionality. \nLift must charge anywhere on the track via continuous AC charging. \nLifting speed must be minimum 2 inches per second at maximum load capacity, with a soft/slow start and stop. \nSupplier must be able to provide a lift with automatic, hands free, dynamic body weight support and fall protection in real time during rehab or mobility sessions; clinical staff must be able to enter a specified  offload  weight directly into the hand control, after which the lift must continually offload the specified weight as patient moves and their center of gravity changes, without the need for staff to continue operating the hand control. Offload weight must be adjustable during a single session so that a patient can progress during that session. \n\nThe associated North American Industry Classification System (NAICS) Code is 339113   Surgical Appliance and Supplies Manufacturing, and the Business Size Standard is 800 Employees.  \nContractors that are capable of meeting this requirement are asked to provide a response via the email address listed below. Please provide at minimum the following information in your response:\n(1) Business Name and Address\n(2) Point of Contact Name, Phone Number and E-mail Address \n(3) SAM Unique Entity ID (UEI) \n(4) Type of Small Business (if applicable): Service-Disabled Veteran Owned, Veteran Owned Small Business, 8a, HUBZone, Woman-Owned, etc.\n(5) Source of supply if you are not the manufacturer\n(6) Detailed product information/brochures/technical specification/capabilities\n(7) Product Country of Origin\n\nAdditional information:\nAll contractors must be registered with the System for Award Management (SAM) at https://sam.gov.\nAny contractor that believes they are capable and desires to claim preference for small business status must be registered with the SBA and meet the requirements of FAR 19.102.\nAny contractor that believes they are capable and desires to claim preference for SDVOSB or VOSB status must be registered with the SBA Veteran Small Business Certification Program (VetCert).\nResponses due to Jeffrey Rozema, Contract Specialist, by Friday, February 21, 2025, at 5:00 PM Eastern Time.  Please e-mail all responses to jeffrey.rozema@va.gov.","text":"This is a SOURCES SOUGHT request for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time.\nThis notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine the interest and capability of any contractor to meet the requirements listed below, with an emphasis on service-disabled veteran owned small business, veteran owned small business, and other small business.\nThe Department of Veterans Affairs, Regional Procurement Office Central, Network Contracting Office 10 is seeking sources for Guldmann (or equivalent) patient ceiling lifts for the Aleda E. Lutz VA Medical Center located at 1500 Weiss Street, Saginaw, MI 48602. The patient ceiling lifts will be installed in the Saginaw VA s Morgue, Nuclear Medicine, Surgery, and Therapy Gyms. The Guldmann lift systems include the following:\n4x4 Room Covering System GH3+ 605 lbs. SWL. w/Scale and Hanger Bar (Includes 1 Mobilization and Tear Out), 1 Each\nStraight Track System GH3+ 605 lbs. SWL. w/Scale includes Hanger Bar, 1 Each\n4x4 Room Covering System GH3+ 605 lbs. SWL. w/Scale and Hanger Bar (Includes 1 Mobilization and Tear Out), 1 Each\nRoom Covering System GH3+ 605 lbs. SWL. w/Trainer Module, Positioning Lock System and Hanger Bar. (Includes 1 mobilization and tear out), 1 Each\nRoom Covering System into Straight Rail GH3+ 605 lbs. SWL. w/Trainer Module and and Hanger Bar. (Includes 1 mobilization and tear out), 1 Each\n3G Porgram-10 Year Annual Inspection/Preventative Maintenance and Extended Parts and Labor Warranty, 5 Each\nDesign/drafting and installation services are also required.\nLift systems must meet the following characteristics/specifications:\nThere must be a lift offered from the manufacturer that can lift at least 600lbs.\nThe transfer gate must be able to support at least 600lbs.\nThe Morgue, Nuclear Medicine, and Surgery rooms must have a X-Y track system (room covering track system) in which the motor is mounted on a perpendicular moving rail that is attached to two parallel recessed fixed rails allowing the lift to travel in four directions (side-to-side and front-to-back).\nTherapy Gym Room 1400-22 must have a X-Y track system in which the motor is mounted on a perpendicular moving rail that is attached to two parallel recessed fixed rails allowing the lift to travel in four directions (side-to-side and front-to-back).\nThe lifts must have a recessed room covering system. The positioning lock system will be needed on the system in Therapy Gym Room 1400-22. A transfer gait will be needed on the system in Therapy Gym Room B600-22 to transfer the Veteran from the room covering system to the straight rail.\nThe track rails must be capable of accommodating stationary lock for lift unit and/or stationary lock for Traverse Rail with user capability via hand control to separately position and lock the motor and/or the traverse rail in designated location(s) when indicated for patient care activity.\nThe hand control must be wired, with LCD screen capable of displaying patient weight and lift usage information for enable staff to easily read the patient s weight.\nScale must be internal to maximize hanger bar height and thus lift functionality.\nLift must charge anywhere on the track via continuous AC charging.\nLifting speed must be minimum 2 inches per second at maximum load capacity, with a soft/slow start and stop.\nSupplier must be able to provide a lift with automatic, hands free, dynamic body weight support and fall protection in real time during rehab or mobility sessions; clinical staff must be able to enter a specified offload weight directly into the hand control, after which the lift must continually offload the specified weight as patient moves and their center of gravity changes, without the need for staff to continue operating the hand control. Offload weight must be adjustable during a single session so that a patient can progress during that session.\n\nThe associated North American Industry Classification System (NAICS) Code is 339113 Surgical Appliance and Supplies Manufacturing, and the Business Size Standard is 800 Employees.\nContractors that are capable of meeting this requirement are asked to provide a response via the email address listed below. Please provide at minimum the following information in your response:\n(1) Business Name and Address\n(2) Point of Contact Name, Phone Number and E-mail Address\n(3) SAM Unique Entity ID (UEI)\n(4) Type of Small Business (if applicable): Service-Disabled Veteran Owned, Veteran Owned Small Business, 8a, HUBZone, Woman-Owned, etc.\n(5) Source of supply if you are not the manufacturer\n(6) Detailed product information/brochures/technical specification/capabilities\n(7) Product Country of Origin\n\nAdditional information:\nAll contractors must be registered with the System for Award Management (SAM) at https://sam.gov.\nAny contractor that believes they are capable and desires to claim preference for small business status must be registered with the SBA and meet the requirements of FAR 19.102.\nAny contractor that believes they are capable and desires to claim preference for SDVOSB or VOSB status must be registered with the SBA Veteran Small Business Certification Program (VetCert).\nResponses due to Jeffrey Rozema, Contract Specialist, by Friday, February 21, 2025, at 5:00 PM Eastern Time. Please e-mail all responses to jeffrey.rozema@va.gov.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25025Q0299","place_of_performance":{"zip":"48602","city":{"name":"Saginaw"},"state":{"name":"MI"},"street":"Department of Veterans Affairs Aleda E. Lutz VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"1500 Weiss Street"},"product_service_code":"6515"}],"due_at":"2025-02-21T22:00:00Z","due_date":"2025-02-21","closes_at":"2025-02-21T22:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","state":"MI","county":"26145","county_name":"Saginaw County","city":"2670520","city_name":"Saginaw","country":"USA","state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-22T10:55:12.590715Z","principal_notice_id":"6c7d92cbfc944078adaeee24415c3df3","description":{"text":"This is a SOURCES SOUGHT request for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time.\nThis notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine the interest and capability of any contractor to meet the requirements listed below, with an emphasis on service-disabled veteran owned small business, veteran owned small business, and other small business.\nThe Department of Veterans Affairs, Regional Procurement Office Central, Network Contracting Office 10 is seeking sources for Guldmann (or equivalent) patient ceiling lifts for the Aleda E. Lutz VA Medical Center located at 1500 Weiss Street, Saginaw, MI 48602. The patient ceiling lifts will be installed in the Saginaw VA s Morgue, Nuclear Medicine, Surgery, and Therapy Gyms. The Guldmann lift systems include the following:\n4x4 Room Covering System GH3+ 605 lbs. SWL. w/Scale and Hanger Bar (Includes 1 Mobilization and Tear Out), 1 Each\nStraight Track System GH3+ 605 lbs. SWL. w/Scale includes Hanger Bar, 1 Each\n4x4 Room Covering System GH3+ 605 lbs. SWL. w/Scale and Hanger Bar (Includes 1 Mobilization and Tear Out), 1 Each\nRoom Covering System GH3+ 605 lbs. SWL. w/Trainer Module, Positioning Lock System and Hanger Bar. (Includes 1 mobilization and tear out), 1 Each\nRoom Covering System into Straight Rail GH3+ 605 lbs. SWL. w/Trainer Module and and Hanger Bar. (Includes 1 mobilization and tear out), 1 Each\n3G Porgram-10 Year Annual Inspection/Preventative Maintenance and Extended Parts and Labor Warranty, 5 Each\nDesign/drafting and installation services are also required.\nLift systems must meet the following characteristics/specifications:\nThere must be a lift offered from the manufacturer that can lift at least 600lbs.\nThe transfer gate must be able to support at least 600lbs.\nThe Morgue, Nuclear Medicine, and Surgery rooms must have a X-Y track system (room covering track system) in which the motor is mounted on a perpendicular moving rail that is attached to two parallel recessed fixed rails allowing the lift to travel in four directions (side-to-side and front-to-back).\nTherapy Gym Room 1400-22 must have a X-Y track system in which the motor is mounted on a perpendicular moving rail that is attached to two parallel recessed fixed rails allowing the lift to travel in four directions (side-to-side and front-to-back).\nThe lifts must have a recessed room covering system. The positioning lock system will be needed on the system in Therapy Gym Room 1400-22. A transfer gait will be needed on the system in Therapy Gym Room B600-22 to transfer the Veteran from the room covering system to the straight rail.\nThe track rails must be capable of accommodating stationary lock for lift unit and/or stationary lock for Traverse Rail with user capability via hand control to separately position and lock the motor and/or the traverse rail in designated location(s) when indicated for patient care activity.\nThe hand control must be wired, with LCD screen capable of displaying patient weight and lift usage information for enable staff to easily read the patient s weight.\nScale must be internal to maximize hanger bar height and thus lift functionality.\nLift must charge anywhere on the track via continuous AC charging.\nLifting speed must be minimum 2 inches per second at maximum load capacity, with a soft/slow start and stop.\nSupplier must be able to provide a lift with automatic, hands free, dynamic body weight support and fall protection in real time during rehab or mobility sessions; clinical staff must be able to enter a specified offload weight directly into the hand control, after which the lift must continually offload the specified weight as patient moves and their center of gravity changes, without the need for staff to continue operating the hand control. Offload weight must be adjustable during a single session so that a patient can progress during that session.\n\nThe associated North American Industry Classification System (NAICS) Code is 339113 Surgical Appliance and Supplies Manufacturing, and the Business Size Standard is 800 Employees.\nContractors that are capable of meeting this requirement are asked to provide a response via the email address listed below. Please provide at minimum the following information in your response:\n(1) Business Name and Address\n(2) Point of Contact Name, Phone Number and E-mail Address\n(3) SAM Unique Entity ID (UEI)\n(4) Type of Small Business (if applicable): Service-Disabled Veteran Owned, Veteran Owned Small Business, 8a, HUBZone, Woman-Owned, etc.\n(5) Source of supply if you are not the manufacturer\n(6) Detailed product information/brochures/technical specification/capabilities\n(7) Product Country of Origin\n\nAdditional information:\nAll contractors must be registered with the System for Award Management (SAM) at https://sam.gov.\nAny contractor that believes they are capable and desires to claim preference for small business status must be registered with the SBA and meet the requirements of FAR 19.102.\nAny contractor that believes they are capable and desires to claim preference for SDVOSB or VOSB status must be registered with the SBA Veteran Small Business Certification Program (VetCert).\nResponses due to Jeffrey Rozema, Contract Specialist, by Friday, February 21, 2025, at 5:00 PM Eastern Time. Please e-mail all responses to jeffrey.rozema@va.gov.","html":"This is a SOURCES SOUGHT request for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time.  \nThis notice is intended strictly for market research.  The purpose of this Sources Sought notice is to determine the interest and capability of any contractor to meet the requirements listed below, with an emphasis on service-disabled veteran owned small business, veteran owned small business, and other small business.  \nThe Department of Veterans Affairs, Regional Procurement Office Central, Network Contracting Office 10 is seeking sources for Guldmann (or equivalent) patient ceiling lifts for the Aleda E. Lutz VA Medical Center located at 1500 Weiss Street, Saginaw, MI 48602. The patient ceiling lifts will be installed in the Saginaw VA s Morgue, Nuclear Medicine, Surgery, and Therapy Gyms. The Guldmann lift systems include the following:\n4x4 Room Covering System GH3+ 605 lbs. SWL. w/Scale and Hanger Bar (Includes 1 Mobilization and Tear Out), 1 Each\nStraight Track System GH3+ 605 lbs. SWL. w/Scale includes Hanger Bar, 1 Each\n4x4 Room Covering System GH3+ 605 lbs. SWL. w/Scale and Hanger Bar (Includes 1 Mobilization and Tear Out), 1 Each\nRoom Covering System GH3+ 605 lbs. SWL. w/Trainer Module, Positioning Lock System and Hanger Bar. (Includes 1 mobilization and tear out), 1 Each\nRoom Covering System into Straight Rail GH3+ 605 lbs. SWL. w/Trainer Module and and Hanger Bar. (Includes 1 mobilization and tear out), 1 Each\n3G Porgram-10 Year Annual Inspection/Preventative Maintenance and Extended Parts and Labor Warranty, 5 Each\nDesign/drafting and installation services are also required.\nLift systems must meet the following characteristics/specifications:\nThere must be a lift offered from the manufacturer that can lift at least 600lbs. \nThe transfer gate must be able to support at least 600lbs. \nThe Morgue, Nuclear Medicine, and Surgery rooms must have a X-Y track system (room covering track system) in which the motor is mounted on a perpendicular moving rail that is attached to two parallel recessed fixed rails allowing the lift to travel in four directions (side-to-side and front-to-back).\nTherapy Gym Room 1400-22 must have a X-Y track system in which the motor is mounted on a perpendicular moving rail that is attached to two parallel recessed fixed rails allowing the lift to travel in four directions (side-to-side and front-to-back).  \nThe lifts must have a recessed room covering system. The positioning lock system will be needed on the system in Therapy Gym Room 1400-22. A transfer gait will be needed on the system in Therapy Gym Room B600-22 to transfer the Veteran from the room covering system to the straight rail.\nThe track rails must be capable of accommodating stationary lock for lift unit and/or stationary lock for Traverse Rail with user capability via hand control to separately position and lock the motor and/or the traverse rail in designated location(s) when indicated for patient care activity. \nThe hand control must be wired, with LCD screen capable of displaying patient weight and lift usage information for enable staff to easily read the patient s weight.\nScale must be internal to maximize hanger bar height and thus lift functionality. \nLift must charge anywhere on the track via continuous AC charging. \nLifting speed must be minimum 2 inches per second at maximum load capacity, with a soft/slow start and stop. \nSupplier must be able to provide a lift with automatic, hands free, dynamic body weight support and fall protection in real time during rehab or mobility sessions; clinical staff must be able to enter a specified  offload  weight directly into the hand control, after which the lift must continually offload the specified weight as patient moves and their center of gravity changes, without the need for staff to continue operating the hand control. Offload weight must be adjustable during a single session so that a patient can progress during that session. \n\nThe associated North American Industry Classification System (NAICS) Code is 339113   Surgical Appliance and Supplies Manufacturing, and the Business Size Standard is 800 Employees.  \nContractors that are capable of meeting this requirement are asked to provide a response via the email address listed below. Please provide at minimum the following information in your response:\n(1) Business Name and Address\n(2) Point of Contact Name, Phone Number and E-mail Address \n(3) SAM Unique Entity ID (UEI) \n(4) Type of Small Business (if applicable): Service-Disabled Veteran Owned, Veteran Owned Small Business, 8a, HUBZone, Woman-Owned, etc.\n(5) Source of supply if you are not the manufacturer\n(6) Detailed product information/brochures/technical specification/capabilities\n(7) Product Country of Origin\n\nAdditional information:\nAll contractors must be registered with the System for Award Management (SAM) at https://sam.gov.\nAny contractor that believes they are capable and desires to claim preference for small business status must be registered with the SBA and meet the requirements of FAR 19.102.\nAny contractor that believes they are capable and desires to claim preference for SDVOSB or VOSB status must be registered with the SBA Veteran Small Business Certification Program (VetCert).\nResponses due to Jeffrey Rozema, Contract Specialist, by Friday, February 21, 2025, at 5:00 PM Eastern Time.  Please e-mail all responses to jeffrey.rozema@va.gov.","origin":"detail"},"contacts":[{"name":"Jeffrey Rozema","role":"primary","email":"jeffrey.rozema@va.gov","phone":"269-966-5600 x36450","title":"Contracting Officer"}],"place_of_performance":{"zip":"48602","city":{"name":"Saginaw"},"state":{"name":"MI"},"street":"Department of Veterans Affairs Aleda E. Lutz VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"1500 Weiss Street"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"naics_codes":["339113"],"award":{"awardee":{}},"attachments":[{"resource_id":"4a411711894847e4943c95fb4e16fded","name":"36C25025Q0299.docx","kind":"file","mime_type":".docx","size_bytes":19692,"posted_at":"2025-02-13T16:43:25.185Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/4a411711894847e4943c95fb4e16fded/download","mirrored":false},{"resource_id":"36f2bf9925f744c593c87253bfb8b2fa","name":"Agency Homepage","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2025-02-13T16:43:25.185Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov","mirrored":false}],"awards":[],"related":[{"key":"36C25027Q0014","latest_notice_id":"b13cc87179e947e7b42da2de44a6bde1","title":"J061--541 Electrical Power Distribution Equipment Testing, Inspection, and Maintenance - VAMC Cleveland","solicitation_number":"36C25027Q0014","notice_type":"k","first_type":"k","first_posted":"2026-10-09","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"238210","psc":"J061","set_aside":"SBA","state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C25027Q0123","latest_notice_id":"fb53a332644a4c8fa983bf28c8643d2d","title":"S222--Sources Sought - Hazardous Waste Removal/Disposal Northeast Ohio VA Healthcare System - Cleveland, OH","solicitation_number":"36C25027Q0123","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T18:30:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"562112","psc":"S222","set_aside":null,"state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C25027B0009","latest_notice_id":"85b83d408f1f422885991142c2734b45","title":"Z1DA--FY27 NRM - VISN Base Modernize Nurse Call - 539-23-101","solicitation_number":"36C25027B0009","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"},{"key":"36C25027B0008","latest_notice_id":"5afe716a38494a6f84b1e84205805f86","title":"Z1DA--FY27 NRM - VISN Base Install Roof Equipment Railings - 539-22-206","solicitation_number":"36C25027B0008","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"},{"key":"36C25027B0005","latest_notice_id":"2cb4a6354be04cc89c5d6125945b1892","title":"Z1DA--***FY27 Requirement*** First Floor X Ray - Room CC157 553-CSI-022","solicitation_number":"36C25027B0005","notice_type":"p","first_type":"p","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"MI","county":"26163","county_name":"Wayne County","city":"2622000","city_name":"Detroit","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"}],"similar_open":[{"key":"PANDTA26P0000036815","latest_notice_id":"b8bc3f96732e4e0fb7ca11726e55ce4b","title":"Sources Sought: Chemical Cannister","solicitation_number":"PANDTA-26-P-0000036815","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-12-17T22:00:00Z","due_date":"2026-12-17","closes_at":"2026-12-17T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912CH","office_name":"W6QK ACC- DTA","naics":"339113","psc":"4240","set_aside":null,"state":"MI","county":"26099","county_name":"Macomb County","city":"2684000","city_name":"Warren","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C26027Q0130","latest_notice_id":"865639d03bae440aaa4a2e2195e0abf9","title":"6515--SOURCES SOUGHT NOTICE FOR HEAD, SHOULDER, AND UPPER-EXTREMITY POSITIONING ACCESSORIES FOR THE MAQUET MEERA 7200 OPERATING TABLE","solicitation_number":"36C26027Q0130","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":2,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"339113","psc":"6515","set_aside":null,"state":"WA","county":"53063","county_name":"Spokane County","city":"5367000","city_name":"Spokane","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"N0010427QLA17","latest_notice_id":"5958ba02b5c94595a30747ebb8d1c461","title":"VALVE,BREATHING APP","solicitation_number":"N0010427QLA17","notice_type":"o","first_type":"o","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-27T20:30:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"339113","psc":"4240","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"IN THE SCHEDULE. ^^ \"ALL FREIGHT IS FOB ORIGIN","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"}],"similar_open_total":20,"indexable":false}