{"canonical":"https://sealedbidder.com/opportunities/36c25025q0255","key":"36C25025Q0255","url":"https://sealedbidder.com/opportunities/36c25025q0255","title":"Q301--Reference Lab Services for Battle Creek VAMC & Wyoming CBOC","solicitation_number":"36C25025Q0255","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-02-25T17:00:00Z","first_posted":"2025-02-11","last_posted":"2025-02-11","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"621511","psc":"Q301","set_aside":"SDVOSBC","place_state":"MI","place_scope":"site","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"26025","place_county_name":"Calhoun County","place_city":"2605920","place_city_name":"Battle Creek","winner":null,"award_amount":null,"publications":[{"notice_id":"023d685eb63a42ce83f7fb8660acfc23","title":"Q301--Reference Lab Services for BC","solicitation_number":"36C25025Q0255","notice_type":"r","base_type":"r","posted":"2025-02-11","posted_at":"2025-02-11T16:48:48.884Z","due_at":"2025-02-25T17:00:00Z","due_date":"2025-02-25","cancelled":false,"archived":true,"archive_date":"2025-05-26","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/023d685eb63a42ce83f7fb8660acfc23/view","enriched":true,"history":[{"index":3,"title":"Q301--Reference Lab Services for Battle Creek VAMC & Wyoming CBOC","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-11T21:00:09.387Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"d57430295cf9497599f6cc793c16f04f","solicitation_number":"36C25025Q0255","parent_opportunity_id":"023d685eb63a42ce83f7fb8660acfc23"},{"index":1,"title":"Q301--Reference Lab Services for BC","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-11T16:48:48.884Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"023d685eb63a42ce83f7fb8660acfc23","solicitation_number":"36C25025Q0255"}]},{"notice_id":"d57430295cf9497599f6cc793c16f04f","title":"Q301--Reference Lab Services for Battle Creek VAMC & Wyoming CBOC","solicitation_number":"36C25025Q0255","notice_type":"r","base_type":"r","posted":"2025-02-11","posted_at":"2025-02-11T21:00:09.387Z","due_at":"2025-02-25T17:00:00Z","due_date":"2025-02-25","cancelled":false,"archived":true,"archive_date":"2025-05-26","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/d57430295cf9497599f6cc793c16f04f/view","enriched":true,"history":[{"index":3,"title":"Q301--Reference Lab Services for Battle Creek VAMC & Wyoming CBOC","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-11T21:00:09.387Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"d57430295cf9497599f6cc793c16f04f","solicitation_number":"36C25025Q0255","parent_opportunity_id":"023d685eb63a42ce83f7fb8660acfc23"},{"index":1,"title":"Q301--Reference Lab Services for BC","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-11T16:48:48.884Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"023d685eb63a42ce83f7fb8660acfc23","solicitation_number":"36C25025Q0255"}]}],"latest_notice_id":"d57430295cf9497599f6cc793c16f04f","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-02-11","posted_at":"2025-02-11T16:48:48.884Z","created_at":"2025-02-11T16:48:41.372Z","modified_at":"2025-05-27T03:55:52.677Z","response_deadline":{"raw":"2025-02-25T12:00:00-05:00","utc":"2025-02-25T17:00:00Z","date":"2025-02-25","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/023d685eb63a42ce83f7fb8660acfc23/view"},"naics":{"codes":["621511"],"primary":"621511"},"title":"Q301--Reference Lab Services for BC","agency":{"office":{"code":"36C250","name":"250-NETWORK CONTRACT OFFICE 10 (36C250)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"organization_id":"100167099","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-05-26","archive_type":"auto_custom"},"history":[{"index":3,"title":"Q301--Reference Lab Services for Battle Creek VAMC & Wyoming CBOC","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-11T21:00:09.387Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"d57430295cf9497599f6cc793c16f04f","solicitation_number":"36C25025Q0255","parent_opportunity_id":"023d685eb63a42ce83f7fb8660acfc23"},{"index":1,"title":"Q301--Reference Lab Services for BC","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-11T16:48:48.884Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"023d685eb63a42ce83f7fb8660acfc23","solicitation_number":"36C25025Q0255"}],"contacts":[{"name":"Morgan Stein","role":"primary","email":"Morgan.Stein@va.gov","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"023d685eb63a42ce83f7fb8660acfc23","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"023d685eb63a42ce83f7fb8660acfc23","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-22T12:43:12.450923891Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"73b8d2be7623d9307c6dfe8e2c5a16b6c679accc76722c8c3c65f4a97cda5b01","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-22T12:43:12.450923891Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"THIS IS NOT A SOLICITATION, THIS IS A SOURCES SOUGHT NOTICE ONLY and is issued in accordance with Federal Acquisition Regulation (FAR) 10 Market Research, to conduct market research.  Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. This Sources Sought Notice is issued solely for information and planning purposes and does not constitute a solicitation or guarantee to issue a solicitation in the future. This Sources Sought Notice does not commit the Government to contract for any supply or service. All information submitted in response to this announcement is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government. Not responding to this Sources Sought Notice does not preclude participation in any future solicitation, if issued. This announcement is based on the best information available at this time and is subject to future modification.\n\nPurpose and Objectives\nThe Battle Creek VA Medical Center located at 5500 Armstrong Road Battle Creek, MI 49037, and the Wyoming Community Based Outreach Center (CBOC) located at 5838 Metro Way SW, Wyoming, MI 49519; require a contractor to provide reference laboratory testing services in accordance with the Performance Work Statement (PWS) and test list. The Government intends to award a five-year Indefinite Delivery Indefinite Quantity (IDIQ) contract. \n\nThis Sources Sought Notice is being issued by the Veterans Health Administration (VHA), Network Contracting Office (NCO) 10 located in Kettering, OH as part of market research for planning purposes. \n\nA draft a copy of the PWS and required test list with estimated quantities are attached and is the only information available at this time. \n\nThe applicable NAICS Code is 621511   Medical Laboratories\nSize Standard - $41.5 Million\nProduct Service Code is Q301   Medical   Reference Laboratory Testing\n\nResponses:\nPlease submit your response in accordance with the following instructions:\nResponses are due by 02/11/2025 at 12:00 PM NOON EDT.\nResponses shall be submitted via email to Morgan.Stein@va.gov\nSubject line of the email shall include this Sources Sought Notice Number   Battle Creek and Wyoming Reference Laboratory Testing   Firm Name \nComplete sections C-K and sign acknowledgement statement\nSubmit this document with any relevant attachments \nContractor Point of Contact to include:\nName:\nTitle:\nPhone:\nEmail:\nCompany Information to include:\nName:\nAddress:\nDUNs Number:\nTax ID Number:\nBusiness Size:\nBusiness Size/Type:  Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), 8(a), Hub Zone Small Business, Women Owned Small Business (WOSB), Small Disadvantaged Business (SDB), Small Business, or Large Business.\nAll prospective Contractors are reminded that in accordance with FAR 4.11 they shall be registered in the System for Award Management (SAM) database and shall complete annual Representations and Certifications in SAM prior to any offer.  SAM is located at http://www.sam.gov and consolidated the capabilities of CCR/FedReg, ORCA, and EPLS.  There is no cost to use SAM.\nFOR SDVOSB/VOSB ONLY:  Please note that if responding as an SDVOSB or VOSB, your company must be registered and certified in the VetCert database, which is available at: Veteran Small Business Certification (sba.gov)   \nPlease include a copy of your VetCert Certification with your response.\nContractors Federal Supply Schedule Contract that carries the desired services.\nIf you do not have a Federal Supply Schedule contract, you shall state  open market :\nProvide the Schedule:\nProvide your GSA/FSS/SAC Contract Number:\nProvide the SIN(s) for reference laboratory testing:\nIf any of the items are not on your GSA/FSS contract you will mark which items are open market.\nContractor shall provide 3 past contracts for the same or similar services:\n\n\nCompany 1\nCompany 2\nCompany 3\nName of Company:\n\n\n\nCompany POC:\n\n\n\nCompany POC phone:\n\n\n\nCompany POC email\n\n\n\nDollar amount of contract:\n\n\n\nContract number:\n\n\n\nPeriod of Performance:\n\n\n\n\nContractor shall respond to the following questions as part of the requirements in the PWS: \n            Y N (check yes or no)\n   Are you able to comply with all the requirements listed in the PWS?\n   Is your laboratory fully licensed/accredited and actively engaged in providing the specific services and laboratory testing outlined in the PWS?\n   Is your laboratory licensed/ accredited by the College of American Pathologists (CAP), The Joint Commission (JTC), or any other licensing and/or accreditation as required by law in order to perform the required testing listed in the PWS?\n   Is your laboratory certified as meeting the requirements of the Department of Health and Human Services Clinical Laboratory Improvement Act of 1988?\n   Is your Laboratory Director an American Board of Pathology, certified Pathologist or American Board of Bioanalysis, certified Bio-analyst? \n   Do you have at least three years of experience providing laboratory services and at least one year experience in transporting biomedical materials?\n   Do you have all the CLIA certifications for the analyte specialties and sub-specialties listed in the PWS? \n   Are you able to comply with the quality review requirements in the PWS?\n   Are you able to provide on-site processing staff in accordance with the PWS?\n   Are you able to provide the equipment, data management system, security, and connectivity requirements in accordance with the PWS section?\n   Are you able to provide a secured web-based portal system, Intranet Laboratory Electronic Data Interchange (LEDI) system, and printer equipment including compatibility with ORACLE EHRM equipment; and have interchange with the VA EHR computer system which will be installed during this potential contract at the time of award in accordance with the PWS?\n   Are you able to meet the requirement for the forthcoming new CERNER computer system that will be utilized, have the capability, and are able to interface with this system when it is implemented; in accordance with the PWS?\n   If awarded a future contract, do you plan to utilize a Sub-Contractor? If so, please provide the following information.\nCompany Name:\nAddress:\nPOC Email:\nDUNs Number:\nBusiness Size:\nDescribe work to be completed by the Sub-Contractor: \nDescribe work to be completed by Contractor:\n   Does the Sub-Contractor have all the appropriate licensure and accreditation mentioned above? \nContractor shall provide CLIA certificate of accreditation listing analyte specialties and sub-specialties listed in the PWS for itself and for its Sub-Contractor. \nContractor shall provide a letter from the Sub-Contractor that demonstrates that the Sub-Contractor agrees to perform all tests not performed by the Contractor, to include those tests that the Contractor is not certified to provide itself. \nContractor shall include any relevant comments for any attachments, if applicable.","text":"THIS IS NOT A SOLICITATION, THIS IS A SOURCES SOUGHT NOTICE ONLY and is issued in accordance with Federal Acquisition Regulation (FAR) 10 Market Research, to conduct market research. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. This Sources Sought Notice is issued solely for information and planning purposes and does not constitute a solicitation or guarantee to issue a solicitation in the future. This Sources Sought Notice does not commit the Government to contract for any supply or service. All information submitted in response to this announcement is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government. Not responding to this Sources Sought Notice does not preclude participation in any future solicitation, if issued. This announcement is based on the best information available at this time and is subject to future modification.\n\nPurpose and Objectives\nThe Battle Creek VA Medical Center located at 5500 Armstrong Road Battle Creek, MI 49037, and the Wyoming Community Based Outreach Center (CBOC) located at 5838 Metro Way SW, Wyoming, MI 49519; require a contractor to provide reference laboratory testing services in accordance with the Performance Work Statement (PWS) and test list. The Government intends to award a five-year Indefinite Delivery Indefinite Quantity (IDIQ) contract.\n\nThis Sources Sought Notice is being issued by the Veterans Health Administration (VHA), Network Contracting Office (NCO) 10 located in Kettering, OH as part of market research for planning purposes.\n\nA draft a copy of the PWS and required test list with estimated quantities are attached and is the only information available at this time.\n\nThe applicable NAICS Code is 621511 Medical Laboratories\nSize Standard - $41.5 Million\nProduct Service Code is Q301 Medical Reference Laboratory Testing\n\nResponses:\nPlease submit your response in accordance with the following instructions:\nResponses are due by 02/11/2025 at 12:00 PM NOON EDT.\nResponses shall be submitted via email to Morgan.Stein@va.gov\nSubject line of the email shall include this Sources Sought Notice Number Battle Creek and Wyoming Reference Laboratory Testing Firm Name\nComplete sections C-K and sign acknowledgement statement\nSubmit this document with any relevant attachments\nContractor Point of Contact to include:\nName:\nTitle:\nPhone:\nEmail:\nCompany Information to include:\nName:\nAddress:\nDUNs Number:\nTax ID Number:\nBusiness Size:\nBusiness Size/Type: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), 8(a), Hub Zone Small Business, Women Owned Small Business (WOSB), Small Disadvantaged Business (SDB), Small Business, or Large Business.\nAll prospective Contractors are reminded that in accordance with FAR 4.11 they shall be registered in the System for Award Management (SAM) database and shall complete annual Representations and Certifications in SAM prior to any offer. SAM is located at http://www.sam.gov and consolidated the capabilities of CCR/FedReg, ORCA, and EPLS. There is no cost to use SAM.\nFOR SDVOSB/VOSB ONLY: Please note that if responding as an SDVOSB or VOSB, your company must be registered and certified in the VetCert database, which is available at: Veteran Small Business Certification (sba.gov)\nPlease include a copy of your VetCert Certification with your response.\nContractors Federal Supply Schedule Contract that carries the desired services.\nIf you do not have a Federal Supply Schedule contract, you shall state open market :\nProvide the Schedule:\nProvide your GSA/FSS/SAC Contract Number:\nProvide the SIN(s) for reference laboratory testing:\nIf any of the items are not on your GSA/FSS contract you will mark which items are open market.\nContractor shall provide 3 past contracts for the same or similar services:\n\nCompany 1\nCompany 2\nCompany 3\nName of Company:\n\nCompany POC:\n\nCompany POC phone:\n\nCompany POC email\n\nDollar amount of contract:\n\nContract number:\n\nPeriod of Performance:\n\nContractor shall respond to the following questions as part of the requirements in the PWS:\nY N (check yes or no)\nAre you able to comply with all the requirements listed in the PWS?\nIs your laboratory fully licensed/accredited and actively engaged in providing the specific services and laboratory testing outlined in the PWS?\nIs your laboratory licensed/ accredited by the College of American Pathologists (CAP), The Joint Commission (JTC), or any other licensing and/or accreditation as required by law in order to perform the required testing listed in the PWS?\nIs your laboratory certified as meeting the requirements of the Department of Health and Human Services Clinical Laboratory Improvement Act of 1988?\nIs your Laboratory Director an American Board of Pathology, certified Pathologist or American Board of Bioanalysis, certified Bio-analyst?\nDo you have at least three years of experience providing laboratory services and at least one year experience in transporting biomedical materials?\nDo you have all the CLIA certifications for the analyte specialties and sub-specialties listed in the PWS?\nAre you able to comply with the quality review requirements in the PWS?\nAre you able to provide on-site processing staff in accordance with the PWS?\nAre you able to provide the equipment, data management system, security, and connectivity requirements in accordance with the PWS section?\nAre you able to provide a secured web-based portal system, Intranet Laboratory Electronic Data Interchange (LEDI) system, and printer equipment including compatibility with ORACLE EHRM equipment; and have interchange with the VA EHR computer system which will be installed during this potential contract at the time of award in accordance with the PWS?\nAre you able to meet the requirement for the forthcoming new CERNER computer system that will be utilized, have the capability, and are able to interface with this system when it is implemented; in accordance with the PWS?\nIf awarded a future contract, do you plan to utilize a Sub-Contractor? If so, please provide the following information.\nCompany Name:\nAddress:\nPOC Email:\nDUNs Number:\nBusiness Size:\nDescribe work to be completed by the Sub-Contractor:\nDescribe work to be completed by Contractor:\nDoes the Sub-Contractor have all the appropriate licensure and accreditation mentioned above?\nContractor shall provide CLIA certificate of accreditation listing analyte specialties and sub-specialties listed in the PWS for itself and for its Sub-Contractor.\nContractor shall provide a letter from the Sub-Contractor that demonstrates that the Sub-Contractor agrees to perform all tests not performed by the Contractor, to include those tests that the Contractor is not certified to provide itself.\nContractor shall include any relevant comments for any attachments, if applicable.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25025Q0255","place_of_performance":{"zip":"49037","city":{"name":"Battle Creek"},"state":{"name":"MI"},"street":"Department of Veteran's Affairs","country":{"code":"USA","name":"UNITED STATES"},"street2":"Battle Creek VA Medical Center 5500 Armstrong Road"},"product_service_code":"Q301"},{"award":{"awardee":{}},"dates":{"posted":"2025-02-11","posted_at":"2025-02-11T21:00:09.387Z","created_at":"2025-02-11T21:00:07.085Z","modified_at":"2025-05-27T03:55:52.677Z","response_deadline":{"raw":"2025-02-25T12:00:00-05:00","utc":"2025-02-25T17:00:00Z","date":"2025-02-25","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/d57430295cf9497599f6cc793c16f04f/view"},"naics":{"codes":["621511"],"primary":"621511"},"title":"Q301--Reference Lab Services for Battle Creek VAMC & Wyoming CBOC","agency":{"office":{"code":"36C250","name":"250-NETWORK CONTRACT OFFICE 10 (36C250)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"organization_id":"100167099","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-05-26","archive_type":"auto_custom"},"history":[{"index":3,"title":"Q301--Reference Lab Services for Battle Creek VAMC & Wyoming CBOC","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-11T21:00:09.387Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"d57430295cf9497599f6cc793c16f04f","solicitation_number":"36C25025Q0255","parent_opportunity_id":"023d685eb63a42ce83f7fb8660acfc23"},{"index":1,"title":"Q301--Reference Lab Services for BC","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-11T16:48:48.884Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"023d685eb63a42ce83f7fb8660acfc23","solicitation_number":"36C25025Q0255"}],"contacts":[{"name":"Morgan Stein","role":"primary","email":"Morgan.Stein@va.gov","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"d57430295cf9497599f6cc793c16f04f","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"023d685eb63a42ce83f7fb8660acfc23","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-23T00:30:35.963450254Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"52267bcc320c9e5dec0edcd7f20349c2a5dafd0adc06c72358bf71f0fb0d6308","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-23T00:30:35.963450254Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"?.## PERFORMANCE WORK STATEMENT \nVETERANS INTEGRATED SERVICE NETWORK (VISN) 10\nBATTLE CREEK & WYOMING CBOC  REFERENCE LABORATORY TESTING SERVICES\nOverview \nThe Contractor shall enter into an Indefinite-Delivery Indefinite Quantity Contract (IDIQ) with the Battle Creek VAMC and Wyoming CBOC in Michigan to provide reference laboratory testing for the patients enrolled in the participating facilities.  Contractor shall provide all necessary supplies to provide reference laboratory testing services for the participating facilities below and all support facilities of the BCVAMC.  The IDIQ term shall be five (5) years.  This is a firm-fixed price IDIQ. The estimated quantities are for each test per year.\nBackground\nDepartment of Veterans Affairs, Veterans Health Administration (VHA), VISN 10, Battle Creek VAMC and Wyoming CBOC, requires the services of a contractor for reference laboratory testing services. The contractor shall provide reference laboratory testing for the patients enrolled in the participating facilities. Contractor shall provide all necessary supplies to provide reference laboratory testing services for both the participating facilities below and all support facilities.  \nReference Laboratory Services include at minimum specimen preparation and storage; transportation of clinical laboratory specimens; microbiology cultures and stocks; performance of analytical testing; reporting of analytical test results; consultative services; and reports as required by this document.\nPlaces of Performance \n\nBattle Creek VA Medical Center\n5500 Armstrong Road \nBattle Creek, MI 49037 \nUSA\n\nAND \n\nWyoming VA CBOC\n5838 Metro Way SW\nWyoming, MI 49519\nUSA\n\nSUPPORTING FACILITIES\nContractor shall ensure that supplies are provided as required by the Veterans Affairs Medical Center (VAMC).\nA VA courier will collect specimens from support facilities and those specimens will be collected by the contractor courier from their assigned participating facility on the dates and times listed in Section 5 below.\nGovernment reserves the right to add or remove supporting facilities as necessary.\n\nCONTRACTOR RESPONSIBILITIES\nOVERVIEW\nThe Contractor shall provide at minimum:\nAll necessary supplies for specialized specimen collection, testing, transport, and packaging, shipping kits \nSupplies shall be provided as the medical centers require additional supplies to support patient testing needs. (Government will provide Serum 2 supplies)\nCourier (not shipping) and flight services for the transportation of the specimens \nFlights to be made out of an airport that provides the best efficiency in getting the specimens to the contractor while maintaining specimen integrity. Contractor is responsible for specimen integrity once specimen leaves the VA facility.\nCourier service for pick-up of patient samples from facility s laboratory, shall be provided Monday   Saturday and pick-up times required by the site are identified below:\nBattle Creek VAMC   1 pickup Mon-Sat between 6:00PM and 7:00PM\nWyoming CBOC VAMC   1 pickup Mon-Sat between 6:00PM and 7:00PM\nDry ice (if required)\nChain of custody forms (if required)\nSpecimen transport request forms\nReference laboratory testing and reporting with current reference ranges. \nSecured web-based portal system, Intranet Laboratory Electronic Data Interchange (LEDI) system, and printer equipment including compatible ORACLE EHRM equipment.\nContractor must have interchange with the VA EHR computer system which will be installed during this contract at the time of award.\nContractor shall have a single national coding system. \nContractor shall utilize one test code per test nationally.\nContractor shall utilize approved Patient Identifiers \nCustomer telephone service 24/7 365 days a year\nContractor shall have an electronic test menu submission system as the preferred test submission avenue with limited specialty tests to be submitted on paper test submission forms.\nShipping manifest\nMonthly report to the VAMC to include, at a minimum, through an appropriate electronic format: (no PII/PHI can be included)\nTests ordered.\nNumber of unsatisfactory specimens\nNumber of tests performed in current month; and\nCalendar year-to-date with Current Procedural Terminology (CPT) code and cost. Reports to include all testing ordered for the calendar year.  \nThis report shall include pricing per account number for each participating site. \nProvide and maintain a user-friendly public website which allows easy reference for researching test information (test number/CPT coding, patient preparation, test utility, result interpretive guidelines. For tests not listed on public website Contractor shall provide access to their database for client research test information; and\nRoutine test results to the participating ordering facility within twenty-four (24) hours following test completion, except when specimens are picked up the day before a weekend or holiday (in which case the results shall be provided the following business day). The Contractor shall notify the facility within two (2) hours of any critical values or results.\nContractor s billing and utilization reports shall run from the first day of each month through the last day of each month.  For Example: January 1   January 31, February 1   28 or 29(if leap year), and June 1   June 30.\nQUALIFICATIONS\nLicensing and Accreditation\nOnly fully licensed/accredited laboratories actively engaged in providing the specific services and laboratory testing outlined in this solicitation shall be considered.  The Contractor/Subcontractor shall have all licenses, permits, accreditation and certificates required by law and be provided to the CO/COR at the time of award.  The reference laboratory shall be licensed/accredited by the College of American Pathologists (CAP) or The Joint Commission (TJC), or any other licensing and/or Accreditation in order to perform the required testing listed in this PWS.  In addition, the laboratory must be certified as meeting the requirements of the Department of Health and Human Services Clinical Laboratory Improvement Act of 1988 (CLIA).\nThe Contractor shall provide a copy of all relevant permits/licenses and certifications inclusive of all sanctions current or pending throughout the United States of America prior to contract award.  In addition, the Contractor shall be responsible for providing written guarantee or evidence that all Subcontractors have appropriate licensure and accreditation to perform tests that the primary Contractor cannot perform prior to contract award and as requested by the Contracting Officer (CO).  All proposed Subcontractor changes during the contract performance period must have prior approval by the CO. Changes to the requirements shall be addressed by bilateral modification.\nContractor Personnel assigned by the Contractor to perform the services covered by this contract shall be eligible to provide the services of this contract and licensed in a State, Territory, or Commonwealth of the United States or the District of Columbia.  All licenses held by Contractor personnel working on this contract shall be full and unrestricted licenses.  Contractor Personnel assigned by the Contractor to work under this contract shall be licensed by the governing or cognizant licensing board. \nContractor policies and procedures shall comply with Health Insurance Portability and Accountability Act (HIPPA)\nThe Contractor shall notify the Contracting Officer in writing of all malpractice investigation or licensure or certification suspension that concerns the Contractor or Contractor personnel, or any discovery of any disciplinary action taken against laboratory(ies) performing under the contract within 24 hours of notification of an investigation or suspension.\nContractor Personnel\nThe Contractor shall maintain current accreditation and notify the Contracting Officer of all lapses in state license, Clinical Laboratory Improvement Amendments (CLIA) certification, or clinical pathology certification.  The Contractor shall provide access via website or email upon request a copy of the renewed licenses/certificates before expiration.\nLaboratory Director shall be a licensed American Board of Pathology certified pathologist or appropriately certified bio-analyst.\nThe Contractor must have at least three years of experience providing laboratory services and must have at least one-year experience in transporting biomedical materials.\nCLIA certifications shall include approval for testing for the following disciplines/subdisciplines and effective dates of approval for each disciplines/subdisciplines\nHistocompatibility (010)\nBacteriology (110)\nMycobacteriology (115)\nMycology (120)\nParasitology\nVirology (140)\nSyphilis Serology (210)\nGeneral Immunology (220)\nRoutine Chemistry (310)\nUrinalysis (320)\nEndocrinology (330)\nToxicology (340)\nHematology (400)\nImmunohematology ABO Group & Rh type (510)\nImmunohematology Antibody Detection (transfusion) (520)\nImmunohematology Antibody Detection (non-transfusion) (530)\nImmunohematology Antibody Identification (540)\nImmunohematology Compatibility Testing (550)\nHistopathology (610)\nOral Pathology (620)\nSurgical Pathology\nMolecular Biology\nCytology (630)\nRadiobioassay (800)\nCytogenetics (900)\nAny changes to the CLIA certifications should be communicated to the facility within 24 hours. This also applies to the subcontractors.\nThe Contractor is required to provide all technical advisory/recalls/alerts, prior to or simultaneously with field alerts, should be forwarded to the designated individuals determined at contract award.\nThe Government reserves the right to refuse the use of a subcontractor who fails to comply with evidence of accreditation(s) or licensures(s)\nSPECIMEN PREPARATION\nContractor shall supply each Government facility with its commercial laboratory reference test manual to ensure that the collection and storage of specimens are in accordance with Contractor s requirements.\nContractor shall provide all materials necessary to collect and preserve specimens that are destined to the commercial reference laboratory for testing.  These materials include those items that are dictated by and in compliance with the collection requirements of the commercial reference laboratory. \nIf a medicolegal specimen is submitted, the Contractor shall provide its own special forms and special handling procedures to maintain a valid  chain-of-custody possession  and develop the formal documentation necessary for that purpose.  Contractor s testing personnel who performed the analysis may be required to provide Court testimony.  Contractor testimony shall be provided as required at no additional expense to the Government.  \nContractor shall be responsible for storing specimens in such a manner to ensure the integrity of the specimen.\nSPECIMEN TRANSPORATION\nContractor shall provide transportation of primarily biomedical materials that include patient specimens, cultures, and stocks, originating from Government facilities and destined to the contracted commercial reference laboratory.  \nThese specimens are classified as Hazard Materials Class 6, Division 6.2 and are defined in 49 CFR Part 173.134 as those materials that contain or could contain etiologic agents.  Transportation shall be done in such a manner that the safety and integrity of the biomedical material is maintained.\nTransportation/Courier Services for pick-up of patient samples from the Government facilities listed in this document shall be provided by the contractor.\nThe Government reserves the right to adjust the courier pick-up days and times as necessary, provided a two-week notice has been provided and acknowledged by the Contractor at no additional charge to the Government.\nThe Government reserves the right to add or remove courier pick-up locations provided a two-week notice has been provided and acknowledged by the Contractor at no additional charge to the Government.\nProcessing shall begin immediately upon receipt at the testing site and results provided within the laboratory established turnaround times.\nCourier services shall be available seven (7) days a week, including Federal holidays as required.  A list of Federal Holidays can be found in the following Link: Federal Holidays (opm.gov)\nContractor shall provide all necessary supplies for biomedical materials to be transported from the VA medical facility to the performing laboratory.  These supplies shall include at minimum:\nShipping and packaging containers.  Packing material must be capable of maintaining temperature requirements for specimens until they reach the Contractor s laboratory.\nRequired labels and packaging materials for shipping specimens via courier that are infectious, or etiologic agents, in accordance with appropriate requirements of 42 CFR Part 72, 49 CFR Parts 171 and 173, and the Dangerous Goods Regulations of the International Air Transport Association (IATA) consistent with current regulatory updates.  \nTest request forms, preprinted with the appropriate Shipping Section details and account information. \nTest request forms for specialized testing (i.e., cytogenetics, tissue, etc.).\nPrinter and printer supplies including paper, labels, and toner/ ink cartridges, in sufficient quantities to perform work under this contract.\n\nSPECIMEN TESTING\nContractor shall ensure test sample integrity is maintained at all times from the time they are picked up from the participating facility and delivered to the processing laboratory.\nContractor shall provide the full range of laboratory testing capabilities to execute all required test orders as annotated in this agreement.  \nAll the testing should be performed on the Contractors premises or within the Contractor s network labs (as official or qualified subcontractor). Under no circumstance should the contractor allow any patient information to cross the US borders. Contractor referral to the secondary laboratory or subcontractor should be kept to a minimum for control and uniformity purpose. Subcontractor should be held to the same quality standard as specified in the contract. \nContractor shall make available the following test information:\nRequisition form requirements \nAlphabetized test name list\nTest order code\nSpecimen collection and preservation requirements\nTest method employed (indicate if testing performed in duplicate) and interpretations\nTest reference intervals adjusted for age, sex, or race, when required\nTest specific sensitivity, specificity, and interferences, when required\nResult code\nTest critical values if any\nPolicy for critical value notification\nCPT coding\nTest turnaround times (minimum and maximum times indicated); where the turnaround time is defined as the time between receipt of specimen by the Contractor and receipt of results by a government facility.\nSchedule of test performance (specific days of week indicated)\nLocation of test performance by test name (i.e., name of primary laboratory, name of separate branch/division of primary lab, name, and address of secondary (sub-contracted) laboratory must be cited)\nContractor shall notify the Site Contracting Officer Representative (COR) for each participating facility of any test submitted to be processed that does not match this agreement prior to being tested so that the appropriate process can be followed to process the test.\nAll reference laboratory testing is preferred to be tested using test methods that are FDA approved.  \nAny non-FDA approved method being performed shall have a disclaimer and documented validation plan.  \nUpon request, the validation plan and validation results shall be made available to the COR or designee.\nContractor shall ensure the accurate and timely performance of laboratory testing services on all tests within this agreement.\n\nSPECIMEN RETENTION\nAll anatomic pathology materials (e.g., histology blocks, slides, or other diagnostic material) generated by the VA shall be returned within 7 days after final diagnosis is reported. \n\nTEST RESULTS & REPORTS\nTest Results:\nIf the Contractor is unable to perform the test due to issues with the specimen integrity, the Contractor shall inform the VA as soon as possible, via email to the designated COR, with a maximum time of 24-hours of receipt of the specimen.\nOnce testing is completed, the laboratory results shall be transmitted via secured web-based portal system or the LEDI system to each participating facility via VAMC VISTA/CERNER computer system and printer equipment provided by the Contractor that will be located at each participating facility.\nAlternate methods of reporting results in the event of electronic system failure may include:\nElectronic delivery of all reports is preferred.\nFaxed, please verify fax number prior to sending patient results as fax numbers are subject to change:\n269-966-5483 \nAll test results provided by the Contractor/subcontractor shall contain at minimum the following:\nTwo (2) full patient identifiers, one of which is patient s full name\nPhysician s name\nTesting facility name and address\nClinical Laboratory Improvement Amendments CLIA number (if requested)\nAccount number\nDate/time specimen was collected\nDate/time specimen was received\nDate/time test was reported\nContractor generated Laboratory Accession Number\nVA generated Laboratory Accession Number \nTest ordered\nTest result\nFlagged abnormal results\nReference ranges\nType of specimen\nAny additional comments related to test provided by submitting lab\nAny other information the laboratory has that may indicate a questionable validity of test results; and\nUnsatisfactory specimens shall be reported with regard to its unsuitability for testing.\nCorrected reports shall be issued in accordance with accreditation requirements.\nThe Contractor shall return representative slides, anatomic, hematologic, etc., for quality control review when requested.  Quality control slides shall represent duplicate copies of original slides prepared by the Contractor from permanent tissue blocks.  The Contractor shall provide quality control slides to the facility or clinics at the same time the Contractor submits the final reports.   The Contractor shall prepare additional blocks and slides, in quantities specified by the facility for review by pathologists.  For malignant cases, the Contractor shall call results to the submitting facility, and prepare paraffin blocks and slides for review by the Joint Pathology Center (JPC) or other Government Pathology Organization (GPO). For benign cases, the Contractor shall prepare slides for review by the facility.  Upon provision of sample slides by the facility, the Contractor shall provide interpretation of sample slides.  The sample shall include, at a minimum, breast biopsy, thyroid biopsy, mastectomy with nodes, colon resection, lymph node biopsy, and gynecology and non-gynecology cytology.\nThe Contractor shall store all blood and fluid specimens after all testing has been completed in the event repeat or add on testing for one (1) week at conditions that shall maintain sample viability.  Upon request, samples shall be returned to the collecting VA facility via courier at conditions that shall maintain sample viability, at no additional charge to the VA.  All anatomical pathology specimens (i.e., slides, blocks, etc.) shall be returned within two (2) weeks of test completion.\nReports:\nAll Reports shall run from the 1st day of each month through the last day of each month. For Example: January 1   January 31, February 1   28 or 29 (if leap year), and June 1   June 30.\nContractor shall prove consultative services that are consistent with the services offered to other contracted customers without compensation.  These services may include consultations by laboratory professionals or experienced physicians on test or methodology selection or test result interpretation.\nContractor shall provide access to online statistical analysis and metrics of the Government facilities  test utilization reports to assist in the monitoring of ordering trends and utilization patterns. The contractor shall make recommendations to the facilities on mechanisms to reduce their costs and provide recommendations for improvements in testing and results.\nTest utilization (number and cost)\nTrending of test utilization (number and cost)\nLine graph AND\nTotal number\nTest utilization by provider\nContractor shall provide a cumulative workload summary report of tests performed. The summary must include the facility account number, the test name, the test ordering code, monthly test volume, year-to-date test volume, unit test cost, monthly test expenditures and year-to date test expenditures, the VA and Test Lab generated accession numbers, and the name and address of the testing laboratory (contractor and subcontractor). \nA copy of the report shall be delivered electronically to the Contracting Officer and COR by the 10th of the month following the close of the reporting month.\nAll reports shall be submitted in electronic spreadsheet format and have the capability to sort by four (4) different methods:\nFacility account number\nTest names listed alphabetically\nTest names listed in order of year-to-date test frequency (highest to lowest)\nTest names listed in order of year-to-date total test cost (highest to lowest)\nAdditional Administration Requirements / Reports \nThe Contractor shall provide an updated copy of the Excel spreadsheet  Reference Lab Invoice Summary  to the Contracting Officer, COR by the 10th of the month following the close of the reporting month. The Contractor shall update the quantities of tests invoiced during the prior month in this spreadsheet. \nContractor shall provide a monthly listing of any tests listed in Section D, Attachment 2 entitled  Price-Cost Schedule - Battle Creek and Wyoming CBOC Reference Labs  that 1) are no longer performed by contractor or 2) the test name is updated. The Contractor shall highlight the rows RED in the Excel Spreadsheet  Declining Balances Monthly Test Tracker  for any test codes that are no longer performed by the Contractor or have updated test names and make a note in the  Notes  column. These tests will be either removed or updated via a supplemental agreement in accordance with 52.212-4. When invoicing, prior to the test name being updated via contract modification, the Contractor shall reference the previous test code name and new test code name on the invoice.  \nThe Contractor shall make all reasonable effort to notify the VA that a test ordered against the contract is not listed in Section D, Attachment 2, in order to avoid an unauthorized commitment. \nFor tests that are ordered that are not listed in Section D, Attachment 2, the Purchase Card Procedures in Section D, Attachment 7 entitled  Purchase Card Procedures for VA and Contractor  shall be utilized. These procedures include the requirement that the Contractor shall provide an updated Excel Spreadsheet,  Purchase Card Transactions,  that tracks the test name and/or test ordering code, quantity of each test performed, and proposed pricing.\n\nQUALITY REVIEW\nContractor shall provide the following:\nIn accordance with VHA Handbook 1106 a 10% retrospective quality management peer review shall be completed.  This review shall be completed by a second pathologist on at least a quarterly basis for a minimum of 10% of all surgical pathology cases, fine needle aspirates, cytopathology cases and gynecologic cases.\nThis 10% review shall be performed by a pathologist certified in anatomic pathology.  Reviews shall meet these review requirements:\nUnder no circumstances shall a resident physician act as a second reviewer for a staff pathologist.\nUnder no circumstances shall a staff pathologist review a resident physician s diagnosis as this does not constitute a second review.\nIndividuals performing a second review in GYN cytology shall have achieved a current successful GYN cytology competency assessment.\nThe review process shall be random, shall include all types of specimens and shall include a review of the entire case.\nAt least 10% of the cytotechnologist s gynecologic cases that have been interpreted as negative are routinely rescreened and are diagnosed and documented as being negative by a qualified pathologist.\nCases subjected for rescreening shall include some cases from high-risk patients, as well as random negative cases, based upon criteria established by the Chief or Director of Pathology and Laboratory Medical Services.\nAbility to instantly generate reports like cost Management Report, turn-around-time report, Utilization Report and any other quality management report requested by the site.\n\nPURCHASE CARD TRANSACTIONS\nContractor shall follow the Purchase Card Transactions procedures as directed in Section D, Attachment 7 for any tests ordered that were not originally on the contract. \n\nCUSTOMER SERVICE\nContractor shall provide customer service including IT support that is accessible by toll-free telephone service 24 hours per day, 7 days per week to assist Government staff for tracking and resolving related issues/problems that may arise in the performance under this agreement.\nUpon award, the Contractor shall provide the name(s) and telephone number(s) of contractor employees who will address customer services within 24 hours throughout the agreement.\nEnvironment of Care:\nAll significant problems identified shall be reported verbally to the COR within 24 hours. A written corrective plan of action shall be submitted to the COR within five (5) working days. VA timeframes and priorities for completion of action plan items shall be mutually agreed upon by the Contractor and the VA Safety Officer.  The Contractor shall successfully pass the participating Facility  Safety and Infection Control inspections prior to the provision of patient care.\nVA strives to ensure that the patients experience at each of the medical centers provides for convenience of obtaining all possible tests in one visit\nLeadership\nVA Primary Care services and operational activities provided at the participating Facility shall be designed and planned by leadership staff and shall reflect a uniform level of primary care as provided to veterans.  The Contractor under the supervision of the PALMS Pathologists shall effectively manage and direct daily operations, information and support systems, and conserve physical and financial assets while meeting the mission of the VHA. PALMS Pathologists shall provide leadership oversight for improvement of clinical and administrative outcomes. The provision of contracted services shall be described in writing the nature and scope of services provided through contractual agreement. Leaders monitor contracted services by establishing expectations for the performance of the contracted services. Leaders take steps to improve contracted services that do not meet expectations.\nPersonnel Security\nAll Laboratory Directors who manage contractor personnel with direct access to the specimens and data received from and transmitted to the VA are required to complete a background investigation and receive a favorable adjudication from the Office of Security and Law Enforcement. Anyone with administrative or programmer access to a Federal computer system shall have a background investigation commensurate with the level of access granted to the VA computer system as determined by the Information Security Officer in concert with Human Resources Management Staff. These staff shall be operating within the borders of the U.S.A. and its territories.\nContinuing Education\nThe contractor shall provide ongoing continuing education material for Professional Acknowledgement for Continuing Education (PACE), Continuing Medical Education (CME) and Continuing Education (CE). \n\nDATA MANAGEMENT & CONNECTIVITY REQUIREMENTS\nData Management System\nContractor shall provide to the Government all necessary laboratory test parameters (parameters are required for each test contained in a panel) to insure accurate test result transmission between the Government and the Contractor s database.  They shall provide all the IT support required for transition between reference labs, namely building existing and new test codes, test description, interface, troubleshooting and maintenance through the life of the contract. Required test parameters include:  \nOrdering code\nLOINC code\nCPT code\nInterface code\nTest cost\nReference ranges\nUnits of measurement\nTest result interpretation or interpretive remarks, if appropriate\nTesting site (if not performed at the vendor s main laboratory facility\nTest methodology\nSpecimen types\nSpecimen collection and handling requirements\nIndication whether test is a panel/profile test, list of tests included \nThe parameters for all tests in the Contractor s database shall be kept current and be available to the Government sites throughout the performance period of the contract.  Updates to the test parameter information must be provided to Government sites no less than 2 weeks prior to the implementation of any changes.  The Contractor shall provide telephone access to a Contractor s technical representative to respond to any question(s) regarding the laboratory test parameter information. \nContractor shall be approved to be interfaced with ORACLE EHRM and be built at the enterprise level at the time of award.\nThe Contractor shall provide a data management system that meets the following requirements:  \nTest ordering shall be accomplished through a menu that is intuitive, has minimal options, and uses a mouse or touch screen.  Upon selection of the test, the computer shall alert (flag) the user to the type of specimen required and the storage conditions.  It must also alert the user to the location of the laboratory that will be performing the test.\nTest definition, test information, and test requirements must be complete, available and easily accessible.\nShipping manifest shall be generated that identifies the specimens sent to the commercial reference laboratory, transportation conditions, and testing ordered.\nThe status and the results of testing shall be available within published timeframes and easily retrievable by the use of varying options.  At a minimum the options must include: \nSort by patient name \nsort by date; sort by test \nsort by incomplete test.  \nIncomplete tests must have an indication of the pending time until completion.  Alert messages, or other notification, must be generated when testing is delayed beyond published timeframes.   \nReports of test results must be immediately available upon verification of the test result.  Contractor s computer located at the Government site must be able to print test results upon request and reprint retrospective test results.\nEquipment Security\nAny equipment provided by the Contractor to VA which contains a storage device such that when the device is powered down, VA sensitive data remains on it shall be sanitized prior to removal from the VA premises, shall become the property of the Federal Government and remain on Federal property or shall be destroyed in accordance with Department of Veterans Affairs regulations at the time of removal (device decommissioning). Data required by the HIPAA to remain on equipment located on Contractor's property shall be safeguarded in accordance with HIPAA and this information shall be destroyed in accordance with VA requirements when no longer required by HIPAA to be held by the vendor.\nVA Connectivity Requirements\nThe Contractor shall provide each participating facility the capacity to order lab testing and receive results through a secure web-based portal.  The Contractor shall show that this portal meets VA requirements for encryption of sensitive patient information. The requirements that VA utilizes for these types of transmission shall be the Federal Information Processing Standard (FIPS) Publication 140-2. The Contractor shall be responsible for transmission of orders, confirmation of orders, test results, and the preventive maintenance of the system.  Contractor shall be available to train the Facility s staff on the use of the system at each facility. An alternate method of sending orders and receiving results shall be in place in the event of system down time.  A shipping manifest shall be generated that identifies the specimens sent to the reference laboratory, transportation conditions, and testing ordered.\nCERNER is a new VA computer system that will be utilized. The contractor shall ensure they have the ability to interface with CERNER and is operational and validation is complete with full menus complete at the time of contract award.\nThe Contractor shall have an electronic bi-directional interface system.  The Contractor shall meet all Cyber Security requirements to establish an interconnection with the VA for transfer of test ordering details and laboratory test results directly from and into the VA computer system via the appropriate LEDI protocol. The interface shall be designed with a single data interface for the Facility which all sites shall utilize.  The interface shall allow the generation of manifests to identify the specimens to be sent to the reference lab.  Upon receipt of test results, the VA staff shall be able to review/validate test results before release.  The Contractor shall be responsible for the purchase of any licenses for middleware products (e.g., Data Innovations) and hardware for any middleware or interface structure.\nIf the Contractor does not have a bi-directional electronic interface already in place, the Contractor shall have the following implemented within three (3) months of the contract award date. Contractor shall assist staff in the updating of the test database by providing all information required to create new test files for the required tests (i.e., sample requirements, shipping temperatures, reference ranges, CPT codes).  Interface portal shall be connected and approved, including any required hardware, such as dedicated printers for labels and results.  Interface validation shall be completed on the tests that have been updated in the database.\nDue to the difficulties encountered with any major reference laboratory interfacing change or upgrade, Contractor shall temporarily provide a single knowledgeable point of contact for researching correct test information, point(s) of contact for developing, testing, and implementing a client/vendor interface, and then an ongoing point of contact for troubleshooting interface problems. Temporary service shall be in effect until interfacing change or upgrade has been completed.\nThe Contractor shall meet all Enterprise Cyber Security Infrastructure Project (ECSIP) requirements in order to establish an interconnection with the VA for transfer of laboratory test results directly into a VA computer system via the appropriate LEDI protocol. The ECSIP team shall have the ultimate decision on which connection type is appropriate.\nThe Contractor shall provide the following interfacing requirements: Laboratory Information Systems LIS physical connection and translation (drivers) and any required (additional) interface connection license(s) and the Interface shall transmit test results to the host computer via automatic upload.  The interface connection shall be tested and verified before putting into use.\nThe reference laboratory shall meet VA information security and Health Insurance Portability and Accountability Account of 1996 (HIPAA) requirements and shall be able to interface with the current or any new interface partner of the Laboratory Information System. The Contractor shall have all users with VA access complete the VHA privacy training prior to starting services.\nCERNER is a new Computerized Electronic Health Record that VA is in the process of transiting to. The Contractor shall ensure they have the capability and are able to interface with this system when it is implemented in addition to VISTA/CPRS that is currently in place.\nPerformance Improvement\nThe Contractor shall comply with the participating Facility Performance Improvement (PI) program as applicable to Pathology and Laboratory Medicine Service (PALMS). PALMS shall monitor the vendor s Test Assay Turn Around Times (TATs) on a quarterly basis.  Vendor shall provide a quarterly TAT report for all patient testing requests sent for analysis. Quality Assurance Technologists shall provide a quarterly report to participating facility management teams for review.  Contractor PI activities may be directed by the VA facility, VISN or VHA, as well as accreditation or licensing bodies. The Contractor shall abstract, compile and report PI data as requested by the VA. VA Data collection methodology, report format, and reporting deadlines shall be defined by the participating facility. Examples of required PI activities include the VHA Performance Measures/Clinical Practice Guidelines program, and the Joint Commission ORYX or Core Measurement program. It is noted that PI activities are dynamic and subject to change, as driven by current priorities and resources. In all cases, the Contractor shall continually assess for, and act upon, clinical and administrative improvement opportunities. High priority shall be given by the Contractor to the prevention of risk for the patient. The Contractor shall implement process-related internal controls to prevent risk to the veteran. VA monitoring for continuous compliance with Joint Commission standards shall be directed by VA staff and communicated to the Contractor through the COR. VA aggregate and/or practitioner-specific data collected by the VA shall be provided to the Contractor in accordance with established reporting schedules. VA measures related to contract compliance shall be identified by the COR\nInformation and Records Management\nThe participating Facility  Information Management plan shall be followed by the Contractor. Documentation and record keeping shall be in accordance with the Facility  policies and procedures. Strict adherence to all documentation related to the performance of invasive procedures shall be maintained. Identified medical record delinquency data shall be forwarded to the Contractor by the participating facility\nAutomated Data Processing (ADP) Security/HIPPA and Excluded Individuals\nThe VA shall provide access to the Veterans Health Information and Technology Architecture (VISTA) for Contractor employees. All Contractor employees accessing the VISTA system shall be required to sign and abide by all VAAAHS security policies and applicable VA confidentiality statutes, 38 U.S.C. Â§5701, 38 U.S.C. 7332, and the Privacy Act, 5 U.S.C. Â§552a.  Background security investigations shall be completed before access to VISTA may be granted\nHealth and Human Service   Office of Inspector General (HHS/OIG):  To Ensure that the individuals providing services under the contract have not engaged in fraud or abuse regarding Sections 1128 and 1128A of the Social Security Act regarding federal health care programs, the Contractor is required to check the Health and Human Service   Office of Inspector General List of excluded individuals/entities on the OIG Website (www.hhs.gov/oig) for each person providing services under this contract.  Further, the Contractor is required to certify in its proposal that all persons listed in the Contractor s proposal have been compared against the OIG list and are not listed.  During the performance of this contract the Contractor is prohibited from using any individual or business list on the List of Excluded Individuals/Entities\nTelecommunication Interface Requirements\nIn order for contract performance to begin within the shortest time possible after contract award, Contractor must already possess a current VA nationally approved Business Partner Gateway (BPG) Interconnection Security Agreement (ISA) and Memorandum of Understanding (MOU) and have an integrated system approach to facilitate and streamline all aspects of specimen ordering, testing, and reporting.  As such, the Contractor shall develop and program an interface connection to electronically transmit orders, specimen status, and test results between the Contractor s host computer system and the Government s host computer system (VistA).  (NOTE:  A subcontractor may be utilized to outsource the connectivity solution.) \nThe VistA host computer system supports a Universal Interface (UI) and a Generic Instrument Manager (GIM).  The GIM is a commercial hardware and software product that provides electronic connection between the Contractor s host computer and the Government s host computer.  The configuration must provide the required security of the Government host computer system.  The actual electronic connection between the GIM and the Contractor s host system is of the Contractor s choosing. The initial and continual expense of the electronic message connectivity and maintenance shall be borne by the Contractor throughout the performance of the contract.\nContractor shall provide, install, and if necessary, remove, all required telecommunication equipment, hardware, software, and related consumable supplies to support the transmission of electronic data to all sites referred to herein.  This may include, but is not limited to:\nGeneric Instrument Manager (GIM) for the interface connection\nShipping list printers\nBar-code printers\nBack-up result printers connected directly to Contractor s computer system\nAny required communication lines\nSoftware to receive and send orders, display status of and/or test results\nConsumable supplies to maintain the operation of the equipment listed above, e.g., toner, etc.\nContractor shall be responsible for all annual recurring costs associated with support and maintenance of the Generic Instrument Manager (GIM) system including all GIM equipment, software, and instrument connections.  The Generic Instrument Manager will be located in a government secured area.  The Contractor shall coordinate with the respective Government Information Technology Department to access the GIM.\nThe Contractor shall conduct preventive maintenance and repair of Contractor furnished hardware, software, and associated communication lines.  In addition, throughout the performance period of the contract, the Contractor shall repair or replace any malfunctioning hardware or software. \nAll electronic messaging between the two (Contractor and Government) host computer systems using the GIM shall utilize VistA Health Level Seven (HL7) V1.6 technical specifications.  Health Level 7 (HL7) is a registered trademark of Health Level Seven, Inc, a Standards Developing Organization accredited by the American National Standards Institute to author consensus-based standards.  Information regarding HL7 transmission protocols may be accessed through the Health Level Seven, Inc website, www.HL7.org.\nVistA Laboratory Electronic Data Interchange (LEDI):  identifies Government-specific content and encoding tables to be used with HL7 message protocol conventions.  The LEDI specification follows very closely the HL7 V2.3.1 standard.  LEDI identifies encoding tables and HL7 message protocol conventions.  \nLEDI also identifies to the commercial reference laboratory contractor shipping lists containing required specimen demographics and requested tests to be performed.  This list will be provided in printed format during the implementation period.  This information is also available in electronic HL7 format if required.  \n(LEDI) software will provide a HL7 acknowledgement for the receipt of tests results from the contractor.   In the event that electronic communication is disrupted, the contractor shall provide hard copy of specimen results upon demand.  The hard copy must contain Government s assigned specimen identification where specimen identification is defined as a unique Government-assigned number that is associated with each specimen.  This specimen identification number will appear on the test order form, on the specimen label and on the shipping manifest.   \nThe Contractor shall provide the Government with specimen status in response to electronic and verbal query.  Upon test completion, a formatted HL7 message containing specimen test results with Government s assigned specimen identification shall be returned to the requesting medical center.\nContractor shall address within two hours of initial inquiry, interface connection questions where information is required to update, maintain, and support the services of the host-to-host linkage between the Government and the Contractor. \nContractor shall provide in-service training required for the routine loading and care of printers and other hardware located on-site.  The training will ensure that Government staff is capable of performing routine servicing of hardware.\n\nPOLICIES, REGULATIONS, AND COMPLIANCE STANDARDS\nPOLICIES AND REGULATIONS\nPolicy/Handbooks:\nVHA Handbook 1100.17: National Practitioner Data Bank Reports - https://www.va.gov/vhapublications/ViewPublication.asp?pub_ID=2135 \nVHA Handbook 1100.19 Credentialing and Privileging - https://www.va.gov/vhapublications/ViewPublication.asp?pub_ID=2910 \nVHA Handbook 1907.01 Health Information Management and Health Records: https://www.va.gov/vhapublications/ViewPublication.asp?pub_ID=3088 \nPrivacy Act of 1974 (5 U.S.C. 552a) as amended: http://www.justice.gov/oip/foia_updates/Vol_XVII_4/page2.htm \nVHA Handbook 1106.01:  Pathology and Laboratory Medicine Service (P&LMS) Procedures: https://www.va.gov/vhapublications/ViewPublication.asp?pub_ID=3169 \nConformance Standards\nContractor shall maintain full compliance with applicable Federal and State regulations.  All services provided under this contract shall be performed in conformance with the National Fire Protection Agency (NFPA) 99- Health Care Facility Code, Occupational Safety and Health Administration (OSHA), HIPAA, and other applicable national, state, and local regulatory agencies. Contractor shall maintain Clinical Laboratory Improvement Act (CLIA) certificate of accreditation, and The Joint Commission (JC) and the College of American Pathology (CAP, if required) accreditations. A copy of the CLIA certificate shall be provided to the participating Facility when requested\nContractor s Laboratory Director shall be a licensed American Board of Pathology certified pathologist.  The Contractor shall make sure employees have current and valid professional certifications before starting work under this contract.  All contractor personnel shall meet the performance characteristics for accuracy and precision as defined by the 1988 Clinical Laboratory Improvement Act (CLIA) and the Clinical and Laboratory Standards Institute (CLSI) and maintain required licenses.  The Contractor shall maintain current licenses and certificates and provide copies of such to VA upon reasonable written request\nJoint Commission Compliance Standards\nAll applicable VA and VHA policies, procedures and directives shall be followed by the Contractor. The Contractor shall continuously meet or exceed all Joint Commission Hospital standards and provide oversight of care, treatment and services provided through contractual agreement standard LD.04.03.09. The patient population treated within the covered areas consists of veterans with varying physical, psychiatric, and psychological needs. Their conditions are in many cases, directly related to the individual s service to this country. Contract personnel shall provide compassionate care with respect for the special needs of the veteran population served. Care delivered shall reflect the VA Medical Centers mission, vision, and values:\nMISSION: Honor America s veterans by providing exceptional health care that improves their health and well-being.\nVISION: VHA shall continue to be the benchmark of excellence and value in health care and benefits by providing exemplary services that are both patients centered and evidenced based. This care shall be delivered by engaged, collaborative teams in an integrated environment that supports learning, discovery, and continuous improvement. It shall emphasize prevention and population health and contribute to the nation s well-being through education, research, and service in National emergencies.\nVALUES: VHA s five core values are Integrity, Commitment, Advocacy, Respect, and Excellence.  They define our culture and how we care for our Veterans.  They affect outcomes in our daily in\nSPECIAL CONTRACT REQUIREMENTS\nAWARD SPECIFIC INFORMATION\nModifications\nAll modifications shall be given at minimum 60 days for any change takes place.  Modifications shall not be effective until executed.\nModifications that change the terms and conditions of the contract shall be bi-lateral.\nModifications that are administrative in nature may be completed unilaterally by the Government to update attachments, points of contacts, etc.\nPricing\nThis is a Firm Fixed Price (FFP) agreement with estimated quantities.\nPricing shall not change from the awarded pricing.\nVariable Priced Tests shall not be included.  They will either need to be provided a FFP or not orderable through this agreement.\nPricing shall be determined and established at the time of award for ordering periods.  Pricing shall not change.\nTests and Reflex Tests\nThe VA has estimated the quantity of tests that will be needed for the entirety of the agreement, including all ordering periods.  Quantities may increase or decrease based on the Government s needs.  Quantities are not guaranteed.\nAll tests and reflex tests shall be listed in the award with established test codes and pricing.\nOnly the tests and test codes listed in the award are authorized.\nNew Tests:\nmay be added to the award through a bi-lateral modification.  \nshall not be utilized until a bilateral modification is executed.\npricing shall not change for any test replaced due to a test code/description change.\nTests Not Listed in the Award\nTests not listed in this award with the assigned test code/description are not authorized.\nAny test not listed or authorized shall follow a separate process unrelated to this agreement or through VA Community Care.\nContractor shall not process any test not listed in the award nor request payment for tests not listed through this agreement.  Contractor risks non-payment of any test not authorized.\nEstablished Process for Non-Listed Test Codes/Descriptions (Non-Contracted):\nContractor shall set up a Non-Contracted Account Number\nAll Non-Contracted Tests shall not be processed without proper authorization prior to the test being processed.\n\nEMPLOYMENT AND LIABILITY\nThis is a non-personnel services contract. The Contractor shall be responsible for protecting the personnel furnishing services under this contract.  To carry out this responsibility, the Contractor shall provide the following for these personnel, which includes worker s compensation, professional liability insurance, health examinations, income tax withholding and social security payments. The parties agree that Contractor personnel without formal appointments shall not be considered VA employees for any purpose and shall be considered employees of the Contractor\n\nINFECTION CONTROL\nContracted patient care activities shall be integrated into the participating Facility  Infection Control program, and contract staff shall adhere to the Facility Infection Control policies and procedures. The Facility Infection Control Plan shall identify for the Contractor how risks shall be identified, methods to be used to reduce risk, identification and reporting of community-acquired and nosocomial infections, and data collection and reporting requirements. Reports of surveillance, control, prevention, and monitoring activities performed by the part Facility shall be provided, on a routine basis, to the Contractor.\n\nPATIENT SAFETY\nPatient safety shall be a primary focus of the Contractor including compliance with all applicable patient safety goals.  The participating Facility shall inform the Contractor of all applicable Sentinel Events or other Patient Safety Alerts received by the Facility. For every applicable alert, the Contractor shall take the necessary steps to redesign processes to prevent occurrence and provide written feedback to the Contracting Officer Representative (COR) describing prevention actions taken. All events related to patient injury, medication errors, and other breeches of patient safety shall be documented utilizing the Contractor s format and reported to the COR utilizing the part Facility  Incident Report. The Facility shall provide the Contractor with the Sentinel Event definitions in the start-up phase. The Contractor shall verbally notify the Facility COR immediately when a Sentinel Event has occurred, which is to be followed by written notification within one (1) business day or sooner if requested by the medical center. The Facility shall determine when a Root Cause Analysis (RCA) is required of the Contractor. The Contractor shall conduct all Root Cause Analysis according to the Facility policy and within established time frames (45 days). Completed RCAs shall be provided to the Facility COR.\n\nPATIENT RIGHTS\nProtection of all patients  rights is of highest priority. Patient privacy and confidentiality shall be maintained at all times. Computer access shall be granted on a need-to-know basis, and security of computerized information shall be maintained at all times. No patients shall be subject to any research activity without his fully informed consent, subject to study approval by the Investigational Research Board (IRB). The Contractor shall abide by the participating Facility  Code of Ethics, which addresses marketing, admission/transfer/referral/discharge processes, and billing issues. The Contractor and the patient care service provided shall be included in the participating Facility data collection activities related to patient and family complaints and satisfaction issues. Care provided shall respect and integrate the patient s beliefs, values, and cultural influences\n\nGOVERNMENT RESPONSIBILITIES\nCONTRACT PERFORMANCE MONITORING\nContractor's employee(s) shall report to the Laboratory Central Processing area, upon arrival at the VA for specimen pickup.  \nMonitoring of contractor s performance shall be demonstrated through clinical and administrative record reviews.  COR will be responsible for verifying contract compliance.  Contracting Officer's Representative(s) (COR) will designate appropriate VA personnel to monitor services through one or a combination of the following mechanisms:\nDepartments being served will monitor Contractor performance to ensure that services called for in the contract have been received by VA in a timely manner. Any incidents of Contractor noncompliance as evidenced by the monitoring procedures will be forwarded immediately to the Contracting Officer.\nDocumentation of services performed will be reviewed prior to certifying payment.  The COR will perform periodic spot checks and document with the using service to ensure records monitoring.  VA will pay only for services actually provided, and in strict accordance with the Price/Cost Schedule.  Contract monitoring and recordkeeping procedures will be sufficient to ensure proper payment and allow audit verification that services were provided.  \nDepartments being served, through the COR(s), will provide a written statement annually to the Contracting Officer to include a summary of Contractor actions and a statement that all requirements of the contract have been fulfilled as agreed.  This summary evaluation will be submitted 45 days prior to expiration of contract (and/or prior to ordering periods, if applicable).\n\nQUALITY ASSURANCE MONITORING\nContractor shall maintain a Quality Assurance Program related to Reference Laboratory services covered under this contract.  \nContractor shall also participate in a joint quality assurance surveillance program (QASP) with the Government facilities.  This program must minimally address the quality aspects representative to the testing process, i.e., pre-analytical, analytical, and post-analytical variables and include a description of monitoring and evaluation activities.  There must be a mutually agreed upon procedure for responding to issues, problems and/or concerns identified by the Government with details as to whom and in what timeframe the matters will be reconciled.  The issues that may need to be addressed may be general in nature or specific to an incident or event.  The contractor will meet or communicate with the facility/VISN staff for process review and improvement of contract performance on an as needed basis.   \nCopies of licensure/certifications are also required to be submitted upon request by the VA.\n\nPERFORMANCE STANDARDS\nLicensing, Accreditation, & Certification\nPerformance Requirement: Contractor shall maintain and provide CLIA Certification, CAP Accreditation, or equivalent; along with applicable OSHA, Federal, and State Laws for all laboratories, including any subcontractors.\nStandard: Proper certifications shall be kept up to date for the entire performance of this agreement.  This includes all ordering periods.\nAcceptable Quality Level (AQL): 100% Meets Standard, no deviations are authorized.\nSurveillance Method: Periodic Sampling \nFrequency: Contractor shall provide all requested Licenses, Accreditations, and Certifications upon request of the Government at any time for all laboratories, to include all subcontractors.\nTechnical Quality\nPerformance Requirement: Produce high-quality, consistent access to reports, test code changes, errors in technical transmission issues.\nStandard: Meets quality requirements.\nAcceptable Quality Level (AQL): 95% Meets Standard\nSurveillance Method: Quarterly Review\nFrequency: COR to review issues with interfacing and notifications of test code changes, issues with test code results.\nTimeliness\nPerformance Requirement: Processes specimens and report test results within the stated turn-around-times.\nStandard: Timely courier pick-ups, specimen processing and reporting of all test results.\nAcceptable Quality Level (AQL): 90% Meets Standard\nSurveillance Method: Periodic Sampling\nFrequency: COR will review monthly reports\nTest Accuracy\nPerformance Requirement: Contractor shall provide accurate testing in accordance with the tests, test codes, test descriptions, specimen processing, and test results.\nStandard: Number of modified test results, not due to incorrect requisition information from referring lab.\nAcceptable Quality Level (AQL): < 0.02% of all patient results received.\nSurveillance Method: Monthly review\nFrequency: COR will review monthly reports.\nTransportation & Sample Integrity\nPerformance Requirement: Transportation and Quality standards outlined in the Performance Work Statement (PWS).\nStandard: Ensures integrity of samples during transportation to the performing laboratory.\nAcceptable Quality Level (AQL): < 3 lost specimens.\nSurveillance Method: Monthly review.\nFrequency: COR will review monthly reports and courier pick-up logs.\nAnatomic Pathology Random Review\nPerformance Requirement: Contractor shall perform retrospective case review.\nStandard: Staff pathologist to provide case reviews of 10% of all cases for pathology, surgical, cytology, hematopathology, mohs, and fine needle aspirate, etc.\nAcceptable Quality Level (AQL): 100% review and documenting of 10% of all cases.\nSurveillance Method: Monthly review\nFrequency: Contractor shall provide a monthly report to each facility COR providing all results of each review completed.\nBilling and Invoicing\nPerformance Requirement: Contractor shall ensure only tests listed in the award (test codes and descriptions) are billed through the award account.  Contractor shall ensure that they meet all invoicing and billing requirements established in the award.\nStandard: Proper and correct invoicing.\nAcceptable Quality Level (AQL): 90%\nSurveillance Method: Monthly review.\nFrequency: Contractor shall submit on-time invoices with all required information monthly as established in this award.\nTracking Purchase Card Transactions\nPerformance Requirement: Contractor shall follow the procedures in Attachment 7 \nStandard: Proper and correct tracking and notification of test results delivery and payment\nAcceptable Quality Level (AQL): 90%\nSurveillance Method: Monthly Review \nFrequency: Contractor shall submit monthly tracking spreadsheet as established in Attachment 7 \n\nCONTRACT INCREASES UP TO 20% OF TOTAL CONTRACT VALUE\nDue to the unpredictable nature of the quantities and types of tests that will be required, any estimations will fall short of accurate. Therefore, the VA reserves the right to increase the total value of the contract up to no more than 20% of the total contract value by increasing the estimated quantities of tests required, and/or adding new tests to the list via a supplemental agreement in accordance with FAR 52.212-4. These modifications will occur on an estimated quarterly basis.\n\nINVOICING INSTRUCTIONS \nInvoice requirements and supporting documentation: Supporting documentation and invoice must be submitted no later than the 20th workday of the month for the month prior. Subsequent changes or corrections shall be submitted by separate invoice. In addition to information required for submission of a  proper  invoice in accordance with FAR 52.212-4 (g), all invoices must include:\nName and Address of Contractor\nInvoice Date and Invoice Number\nContract Number and Purchase/Task Order Number\nDate of Service\nInvoices shall not include any PII such as full name, social security number, or date of birth.Â \nAttached Excel spreadsheet  Reference Lab Invoice Summary  for each month with the total quantity for the corresponding invoice (this shall include every test in order as they appear in the award, even if the total is zero for that month).\nInvoices shall include the correct PO.\n Invoices shall be submitted electronically through Tungsten Services and be certified by VA COR for payment.\nAny test code names and/or quantities on a contract invoice that was paid for using a purchase card transaction will cause the invoice to be rejected in it s entirety. \nAny test code names and/or quantities that were not able to be provided due to specimen integrity failure will cause the invoice to be rejected in it s entirety.\nWhen invoicing, prior to the test name being updated via contract modification, the Contractor shall reference both the previous test code name and new test code name on the invoice.","text":"?.## PERFORMANCE WORK STATEMENT\nVETERANS INTEGRATED SERVICE NETWORK (VISN) 10\nBATTLE CREEK & WYOMING CBOC REFERENCE LABORATORY TESTING SERVICES\nOverview\nThe Contractor shall enter into an Indefinite-Delivery Indefinite Quantity Contract (IDIQ) with the Battle Creek VAMC and Wyoming CBOC in Michigan to provide reference laboratory testing for the patients enrolled in the participating facilities. Contractor shall provide all necessary supplies to provide reference laboratory testing services for the participating facilities below and all support facilities of the BCVAMC. The IDIQ term shall be five (5) years. This is a firm-fixed price IDIQ. The estimated quantities are for each test per year.\nBackground\nDepartment of Veterans Affairs, Veterans Health Administration (VHA), VISN 10, Battle Creek VAMC and Wyoming CBOC, requires the services of a contractor for reference laboratory testing services. The contractor shall provide reference laboratory testing for the patients enrolled in the participating facilities. Contractor shall provide all necessary supplies to provide reference laboratory testing services for both the participating facilities below and all support facilities.\nReference Laboratory Services include at minimum specimen preparation and storage; transportation of clinical laboratory specimens; microbiology cultures and stocks; performance of analytical testing; reporting of analytical test results; consultative services; and reports as required by this document.\nPlaces of Performance\n\nBattle Creek VA Medical Center\n5500 Armstrong Road\nBattle Creek, MI 49037\nUSA\n\nAND\n\nWyoming VA CBOC\n5838 Metro Way SW\nWyoming, MI 49519\nUSA\n\nSUPPORTING FACILITIES\nContractor shall ensure that supplies are provided as required by the Veterans Affairs Medical Center (VAMC).\nA VA courier will collect specimens from support facilities and those specimens will be collected by the contractor courier from their assigned participating facility on the dates and times listed in Section 5 below.\nGovernment reserves the right to add or remove supporting facilities as necessary.\n\nCONTRACTOR RESPONSIBILITIES\nOVERVIEW\nThe Contractor shall provide at minimum:\nAll necessary supplies for specialized specimen collection, testing, transport, and packaging, shipping kits\nSupplies shall be provided as the medical centers require additional supplies to support patient testing needs. (Government will provide Serum 2 supplies)\nCourier (not shipping) and flight services for the transportation of the specimens\nFlights to be made out of an airport that provides the best efficiency in getting the specimens to the contractor while maintaining specimen integrity. Contractor is responsible for specimen integrity once specimen leaves the VA facility.\nCourier service for pick-up of patient samples from facility s laboratory, shall be provided Monday Saturday and pick-up times required by the site are identified below:\nBattle Creek VAMC 1 pickup Mon-Sat between 6:00PM and 7:00PM\nWyoming CBOC VAMC 1 pickup Mon-Sat between 6:00PM and 7:00PM\nDry ice (if required)\nChain of custody forms (if required)\nSpecimen transport request forms\nReference laboratory testing and reporting with current reference ranges.\nSecured web-based portal system, Intranet Laboratory Electronic Data Interchange (LEDI) system, and printer equipment including compatible ORACLE EHRM equipment.\nContractor must have interchange with the VA EHR computer system which will be installed during this contract at the time of award.\nContractor shall have a single national coding system.\nContractor shall utilize one test code per test nationally.\nContractor shall utilize approved Patient Identifiers\nCustomer telephone service 24/7 365 days a year\nContractor shall have an electronic test menu submission system as the preferred test submission avenue with limited specialty tests to be submitted on paper test submission forms.\nShipping manifest\nMonthly report to the VAMC to include, at a minimum, through an appropriate electronic format: (no PII/PHI can be included)\nTests ordered.\nNumber of unsatisfactory specimens\nNumber of tests performed in current month; and\nCalendar year-to-date with Current Procedural Terminology (CPT) code and cost. Reports to include all testing ordered for the calendar year.\nThis report shall include pricing per account number for each participating site.\nProvide and maintain a user-friendly public website which allows easy reference for researching test information (test number/CPT coding, patient preparation, test utility, result interpretive guidelines. For tests not listed on public website Contractor shall provide access to their database for client research test information; and\nRoutine test results to the participating ordering facility within twenty-four (24) hours following test completion, except when specimens are picked up the day before a weekend or holiday (in which case the results shall be provided the following business day). The Contractor shall notify the facility within two (2) hours of any critical values or results.\nContractor s billing and utilization reports shall run from the first day of each month through the last day of each month. For Example: January 1 January 31, February 1 28 or 29(if leap year), and June 1 June 30.\nQUALIFICATIONS\nLicensing and Accreditation\nOnly fully licensed/accredited laboratories actively engaged in providing the specific services and laboratory testing outlined in this solicitation shall be considered. The Contractor/Subcontractor shall have all licenses, permits, accreditation and certificates required by law and be provided to the CO/COR at the time of award. The reference laboratory shall be licensed/accredited by the College of American Pathologists (CAP) or The Joint Commission (TJC), or any other licensing and/or Accreditation in order to perform the required testing listed in this PWS. In addition, the laboratory must be certified as meeting the requirements of the Department of Health and Human Services Clinical Laboratory Improvement Act of 1988 (CLIA).\nThe Contractor shall provide a copy of all relevant permits/licenses and certifications inclusive of all sanctions current or pending throughout the United States of America prior to contract award. In addition, the Contractor shall be responsible for providing written guarantee or evidence that all Subcontractors have appropriate licensure and accreditation to perform tests that the primary Contractor cannot perform prior to contract award and as requested by the Contracting Officer (CO). All proposed Subcontractor changes during the contract performance period must have prior approval by the CO. Changes to the requirements shall be addressed by bilateral modification.\nContractor Personnel assigned by the Contractor to perform the services covered by this contract shall be eligible to provide the services of this contract and licensed in a State, Territory, or Commonwealth of the United States or the District of Columbia. All licenses held by Contractor personnel working on this contract shall be full and unrestricted licenses. Contractor Personnel assigned by the Contractor to work under this contract shall be licensed by the governing or cognizant licensing board.\nContractor policies and procedures shall comply with Health Insurance Portability and Accountability Act (HIPPA)\nThe Contractor shall notify the Contracting Officer in writing of all malpractice investigation or licensure or certification suspension that concerns the Contractor or Contractor personnel, or any discovery of any disciplinary action taken against laboratory(ies) performing under the contract within 24 hours of notification of an investigation or suspension.\nContractor Personnel\nThe Contractor shall maintain current accreditation and notify the Contracting Officer of all lapses in state license, Clinical Laboratory Improvement Amendments (CLIA) certification, or clinical pathology certification. The Contractor shall provide access via website or email upon request a copy of the renewed licenses/certificates before expiration.\nLaboratory Director shall be a licensed American Board of Pathology certified pathologist or appropriately certified bio-analyst.\nThe Contractor must have at least three years of experience providing laboratory services and must have at least one-year experience in transporting biomedical materials.\nCLIA certifications shall include approval for testing for the following disciplines/subdisciplines and effective dates of approval for each disciplines/subdisciplines\nHistocompatibility (010)\nBacteriology (110)\nMycobacteriology (115)\nMycology (120)\nParasitology\nVirology (140)\nSyphilis Serology (210)\nGeneral Immunology (220)\nRoutine Chemistry (310)\nUrinalysis (320)\nEndocrinology (330)\nToxicology (340)\nHematology (400)\nImmunohematology ABO Group & Rh type (510)\nImmunohematology Antibody Detection (transfusion) (520)\nImmunohematology Antibody Detection (non-transfusion) (530)\nImmunohematology Antibody Identification (540)\nImmunohematology Compatibility Testing (550)\nHistopathology (610)\nOral Pathology (620)\nSurgical Pathology\nMolecular Biology\nCytology (630)\nRadiobioassay (800)\nCytogenetics (900)\nAny changes to the CLIA certifications should be communicated to the facility within 24 hours. This also applies to the subcontractors.\nThe Contractor is required to provide all technical advisory/recalls/alerts, prior to or simultaneously with field alerts, should be forwarded to the designated individuals determined at contract award.\nThe Government reserves the right to refuse the use of a subcontractor who fails to comply with evidence of accreditation(s) or licensures(s)\nSPECIMEN PREPARATION\nContractor shall supply each Government facility with its commercial laboratory reference test manual to ensure that the collection and storage of specimens are in accordance with Contractor s requirements.\nContractor shall provide all materials necessary to collect and preserve specimens that are destined to the commercial reference laboratory for testing. These materials include those items that are dictated by and in compliance with the collection requirements of the commercial reference laboratory.\nIf a medicolegal specimen is submitted, the Contractor shall provide its own special forms and special handling procedures to maintain a valid chain-of-custody possession and develop the formal documentation necessary for that purpose. Contractor s testing personnel who performed the analysis may be required to provide Court testimony. Contractor testimony shall be provided as required at no additional expense to the Government.\nContractor shall be responsible for storing specimens in such a manner to ensure the integrity of the specimen.\nSPECIMEN TRANSPORATION\nContractor shall provide transportation of primarily biomedical materials that include patient specimens, cultures, and stocks, originating from Government facilities and destined to the contracted commercial reference laboratory.\nThese specimens are classified as Hazard Materials Class 6, Division 6.2 and are defined in 49 CFR Part 173.134 as those materials that contain or could contain etiologic agents. Transportation shall be done in such a manner that the safety and integrity of the biomedical material is maintained.\nTransportation/Courier Services for pick-up of patient samples from the Government facilities listed in this document shall be provided by the contractor.\nThe Government reserves the right to adjust the courier pick-up days and times as necessary, provided a two-week notice has been provided and acknowledged by the Contractor at no additional charge to the Government.\nThe Government reserves the right to add or remove courier pick-up locations provided a two-week notice has been provided and acknowledged by the Contractor at no additional charge to the Government.\nProcessing shall begin immediately upon receipt at the testing site and results provided within the laboratory established turnaround times.\nCourier services shall be available seven (7) days a week, including Federal holidays as required. A list of Federal Holidays can be found in the following Link: Federal Holidays (opm.gov)\nContractor shall provide all necessary supplies for biomedical materials to be transported from the VA medical facility to the performing laboratory. These supplies shall include at minimum:\nShipping and packaging containers. Packing material must be capable of maintaining temperature requirements for specimens until they reach the Contractor s laboratory.\nRequired labels and packaging materials for shipping specimens via courier that are infectious, or etiologic agents, in accordance with appropriate requirements of 42 CFR Part 72, 49 CFR Parts 171 and 173, and the Dangerous Goods Regulations of the International Air Transport Association (IATA) consistent with current regulatory updates.\nTest request forms, preprinted with the appropriate Shipping Section details and account information.\nTest request forms for specialized testing (i.e., cytogenetics, tissue, etc.).\nPrinter and printer supplies including paper, labels, and toner/ ink cartridges, in sufficient quantities to perform work under this contract.\n\nSPECIMEN TESTING\nContractor shall ensure test sample integrity is maintained at all times from the time they are picked up from the participating facility and delivered to the processing laboratory.\nContractor shall provide the full range of laboratory testing capabilities to execute all required test orders as annotated in this agreement.\nAll the testing should be performed on the Contractors premises or within the Contractor s network labs (as official or qualified subcontractor). Under no circumstance should the contractor allow any patient information to cross the US borders. Contractor referral to the secondary laboratory or subcontractor should be kept to a minimum for control and uniformity purpose. Subcontractor should be held to the same quality standard as specified in the contract.\nContractor shall make available the following test information:\nRequisition form requirements\nAlphabetized test name list\nTest order code\nSpecimen collection and preservation requirements\nTest method employed (indicate if testing performed in duplicate) and interpretations\nTest reference intervals adjusted for age, sex, or race, when required\nTest specific sensitivity, specificity, and interferences, when required\nResult code\nTest critical values if any\nPolicy for critical value notification\nCPT coding\nTest turnaround times (minimum and maximum times indicated); where the turnaround time is defined as the time between receipt of specimen by the Contractor and receipt of results by a government facility.\nSchedule of test performance (specific days of week indicated)\nLocation of test performance by test name (i.e., name of primary laboratory, name of separate branch/division of primary lab, name, and address of secondary (sub-contracted) laboratory must be cited)\nContractor shall notify the Site Contracting Officer Representative (COR) for each participating facility of any test submitted to be processed that does not match this agreement prior to being tested so that the appropriate process can be followed to process the test.\nAll reference laboratory testing is preferred to be tested using test methods that are FDA approved.\nAny non-FDA approved method being performed shall have a disclaimer and documented validation plan.\nUpon request, the validation plan and validation results shall be made available to the COR or designee.\nContractor shall ensure the accurate and timely performance of laboratory testing services on all tests within this agreement.\n\nSPECIMEN RETENTION\nAll anatomic pathology materials (e.g., histology blocks, slides, or other diagnostic material) generated by the VA shall be returned within 7 days after final diagnosis is reported.\n\nTEST RESULTS & REPORTS\nTest Results:\nIf the Contractor is unable to perform the test due to issues with the specimen integrity, the Contractor shall inform the VA as soon as possible, via email to the designated COR, with a maximum time of 24-hours of receipt of the specimen.\nOnce testing is completed, the laboratory results shall be transmitted via secured web-based portal system or the LEDI system to each participating facility via VAMC VISTA/CERNER computer system and printer equipment provided by the Contractor that will be located at each participating facility.\nAlternate methods of reporting results in the event of electronic system failure may include:\nElectronic delivery of all reports is preferred.\nFaxed, please verify fax number prior to sending patient results as fax numbers are subject to change:\n269-966-5483\nAll test results provided by the Contractor/subcontractor shall contain at minimum the following:\nTwo (2) full patient identifiers, one of which is patient s full name\nPhysician s name\nTesting facility name and address\nClinical Laboratory Improvement Amendments CLIA number (if requested)\nAccount number\nDate/time specimen was collected\nDate/time specimen was received\nDate/time test was reported\nContractor generated Laboratory Accession Number\nVA generated Laboratory Accession Number\nTest ordered\nTest result\nFlagged abnormal results\nReference ranges\nType of specimen\nAny additional comments related to test provided by submitting lab\nAny other information the laboratory has that may indicate a questionable validity of test results; and\nUnsatisfactory specimens shall be reported with regard to its unsuitability for testing.\nCorrected reports shall be issued in accordance with accreditation requirements.\nThe Contractor shall return representative slides, anatomic, hematologic, etc., for quality control review when requested. Quality control slides shall represent duplicate copies of original slides prepared by the Contractor from permanent tissue blocks. The Contractor shall provide quality control slides to the facility or clinics at the same time the Contractor submits the final reports. The Contractor shall prepare additional blocks and slides, in quantities specified by the facility for review by pathologists. For malignant cases, the Contractor shall call results to the submitting facility, and prepare paraffin blocks and slides for review by the Joint Pathology Center (JPC) or other Government Pathology Organization (GPO). For benign cases, the Contractor shall prepare slides for review by the facility. Upon provision of sample slides by the facility, the Contractor shall provide interpretation of sample slides. The sample shall include, at a minimum, breast biopsy, thyroid biopsy, mastectomy with nodes, colon resection, lymph node biopsy, and gynecology and non-gynecology cytology.\nThe Contractor shall store all blood and fluid specimens after all testing has been completed in the event repeat or add on testing for one (1) week at conditions that shall maintain sample viability. Upon request, samples shall be returned to the collecting VA facility via courier at conditions that shall maintain sample viability, at no additional charge to the VA. All anatomical pathology specimens (i.e., slides, blocks, etc.) shall be returned within two (2) weeks of test completion.\nReports:\nAll Reports shall run from the 1st day of each month through the last day of each month. For Example: January 1 January 31, February 1 28 or 29 (if leap year), and June 1 June 30.\nContractor shall prove consultative services that are consistent with the services offered to other contracted customers without compensation. These services may include consultations by laboratory professionals or experienced physicians on test or methodology selection or test result interpretation.\nContractor shall provide access to online statistical analysis and metrics of the Government facilities test utilization reports to assist in the monitoring of ordering trends and utilization patterns. The contractor shall make recommendations to the facilities on mechanisms to reduce their costs and provide recommendations for improvements in testing and results.\nTest utilization (number and cost)\nTrending of test utilization (number and cost)\nLine graph AND\nTotal number\nTest utilization by provider\nContractor shall provide a cumulative workload summary report of tests performed. The summary must include the facility account number, the test name, the test ordering code, monthly test volume, year-to-date test volume, unit test cost, monthly test expenditures and year-to date test expenditures, the VA and Test Lab generated accession numbers, and the name and address of the testing laboratory (contractor and subcontractor).\nA copy of the report shall be delivered electronically to the Contracting Officer and COR by the 10th of the month following the close of the reporting month.\nAll reports shall be submitted in electronic spreadsheet format and have the capability to sort by four (4) different methods:\nFacility account number\nTest names listed alphabetically\nTest names listed in order of year-to-date test frequency (highest to lowest)\nTest names listed in order of year-to-date total test cost (highest to lowest)\nAdditional Administration Requirements / Reports\nThe Contractor shall provide an updated copy of the Excel spreadsheet Reference Lab Invoice Summary to the Contracting Officer, COR by the 10th of the month following the close of the reporting month. The Contractor shall update the quantities of tests invoiced during the prior month in this spreadsheet.\nContractor shall provide a monthly listing of any tests listed in Section D, Attachment 2 entitled Price-Cost Schedule - Battle Creek and Wyoming CBOC Reference Labs that 1) are no longer performed by contractor or 2) the test name is updated. The Contractor shall highlight the rows RED in the Excel Spreadsheet Declining Balances Monthly Test Tracker for any test codes that are no longer performed by the Contractor or have updated test names and make a note in the Notes column. These tests will be either removed or updated via a supplemental agreement in accordance with 52.212-4. When invoicing, prior to the test name being updated via contract modification, the Contractor shall reference the previous test code name and new test code name on the invoice.\nThe Contractor shall make all reasonable effort to notify the VA that a test ordered against the contract is not listed in Section D, Attachment 2, in order to avoid an unauthorized commitment.\nFor tests that are ordered that are not listed in Section D, Attachment 2, the Purchase Card Procedures in Section D, Attachment 7 entitled Purchase Card Procedures for VA and Contractor shall be utilized. These procedures include the requirement that the Contractor shall provide an updated Excel Spreadsheet, Purchase Card Transactions, that tracks the test name and/or test ordering code, quantity of each test performed, and proposed pricing.\n\nQUALITY REVIEW\nContractor shall provide the following:\nIn accordance with VHA Handbook 1106 a 10% retrospective quality management peer review shall be completed. This review shall be completed by a second pathologist on at least a quarterly basis for a minimum of 10% of all surgical pathology cases, fine needle aspirates, cytopathology cases and gynecologic cases.\nThis 10% review shall be performed by a pathologist certified in anatomic pathology. Reviews shall meet these review requirements:\nUnder no circumstances shall a resident physician act as a second reviewer for a staff pathologist.\nUnder no circumstances shall a staff pathologist review a resident physician s diagnosis as this does not constitute a second review.\nIndividuals performing a second review in GYN cytology shall have achieved a current successful GYN cytology competency assessment.\nThe review process shall be random, shall include all types of specimens and shall include a review of the entire case.\nAt least 10% of the cytotechnologist s gynecologic cases that have been interpreted as negative are routinely rescreened and are diagnosed and documented as being negative by a qualified pathologist.\nCases subjected for rescreening shall include some cases from high-risk patients, as well as random negative cases, based upon criteria established by the Chief or Director of Pathology and Laboratory Medical Services.\nAbility to instantly generate reports like cost Management Report, turn-around-time report, Utilization Report and any other quality management report requested by the site.\n\nPURCHASE CARD TRANSACTIONS\nContractor shall follow the Purchase Card Transactions procedures as directed in Section D, Attachment 7 for any tests ordered that were not originally on the contract.\n\nCUSTOMER SERVICE\nContractor shall provide customer service including IT support that is accessible by toll-free telephone service 24 hours per day, 7 days per week to assist Government staff for tracking and resolving related issues/problems that may arise in the performance under this agreement.\nUpon award, the Contractor shall provide the name(s) and telephone number(s) of contractor employees who will address customer services within 24 hours throughout the agreement.\nEnvironment of Care:\nAll significant problems identified shall be reported verbally to the COR within 24 hours. A written corrective plan of action shall be submitted to the COR within five (5) working days. VA timeframes and priorities for completion of action plan items shall be mutually agreed upon by the Contractor and the VA Safety Officer. The Contractor shall successfully pass the participating Facility Safety and Infection Control inspections prior to the provision of patient care.\nVA strives to ensure that the patients experience at each of the medical centers provides for convenience of obtaining all possible tests in one visit\nLeadership\nVA Primary Care services and operational activities provided at the participating Facility shall be designed and planned by leadership staff and shall reflect a uniform level of primary care as provided to veterans. The Contractor under the supervision of the PALMS Pathologists shall effectively manage and direct daily operations, information and support systems, and conserve physical and financial assets while meeting the mission of the VHA. PALMS Pathologists shall provide leadership oversight for improvement of clinical and administrative outcomes. The provision of contracted services shall be described in writing the nature and scope of services provided through contractual agreement. Leaders monitor contracted services by establishing expectations for the performance of the contracted services. Leaders take steps to improve contracted services that do not meet expectations.\nPersonnel Security\nAll Laboratory Directors who manage contractor personnel with direct access to the specimens and data received from and transmitted to the VA are required to complete a background investigation and receive a favorable adjudication from the Office of Security and Law Enforcement. Anyone with administrative or programmer access to a Federal computer system shall have a background investigation commensurate with the level of access granted to the VA computer system as determined by the Information Security Officer in concert with Human Resources Management Staff. These staff shall be operating within the borders of the U.S.A. and its territories.\nContinuing Education\nThe contractor shall provide ongoing continuing education material for Professional Acknowledgement for Continuing Education (PACE), Continuing Medical Education (CME) and Continuing Education (CE).\n\nDATA MANAGEMENT & CONNECTIVITY REQUIREMENTS\nData Management System\nContractor shall provide to the Government all necessary laboratory test parameters (parameters are required for each test contained in a panel) to insure accurate test result transmission between the Government and the Contractor s database. They shall provide all the IT support required for transition between reference labs, namely building existing and new test codes, test description, interface, troubleshooting and maintenance through the life of the contract. Required test parameters include:\nOrdering code\nLOINC code\nCPT code\nInterface code\nTest cost\nReference ranges\nUnits of measurement\nTest result interpretation or interpretive remarks, if appropriate\nTesting site (if not performed at the vendor s main laboratory facility\nTest methodology\nSpecimen types\nSpecimen collection and handling requirements\nIndication whether test is a panel/profile test, list of tests included\nThe parameters for all tests in the Contractor s database shall be kept current and be available to the Government sites throughout the performance period of the contract. Updates to the test parameter information must be provided to Government sites no less than 2 weeks prior to the implementation of any changes. The Contractor shall provide telephone access to a Contractor s technical representative to respond to any question(s) regarding the laboratory test parameter information.\nContractor shall be approved to be interfaced with ORACLE EHRM and be built at the enterprise level at the time of award.\nThe Contractor shall provide a data management system that meets the following requirements:\nTest ordering shall be accomplished through a menu that is intuitive, has minimal options, and uses a mouse or touch screen. Upon selection of the test, the computer shall alert (flag) the user to the type of specimen required and the storage conditions. It must also alert the user to the location of the laboratory that will be performing the test.\nTest definition, test information, and test requirements must be complete, available and easily accessible.\nShipping manifest shall be generated that identifies the specimens sent to the commercial reference laboratory, transportation conditions, and testing ordered.\nThe status and the results of testing shall be available within published timeframes and easily retrievable by the use of varying options. At a minimum the options must include:\nSort by patient name\nsort by date; sort by test\nsort by incomplete test.\nIncomplete tests must have an indication of the pending time until completion. Alert messages, or other notification, must be generated when testing is delayed beyond published timeframes.\nReports of test results must be immediately available upon verification of the test result. Contractor s computer located at the Government site must be able to print test results upon request and reprint retrospective test results.\nEquipment Security\nAny equipment provided by the Contractor to VA which contains a storage device such that when the device is powered down, VA sensitive data remains on it shall be sanitized prior to removal from the VA premises, shall become the property of the Federal Government and remain on Federal property or shall be destroyed in accordance with Department of Veterans Affairs regulations at the time of removal (device decommissioning). Data required by the HIPAA to remain on equipment located on Contractor's property shall be safeguarded in accordance with HIPAA and this information shall be destroyed in accordance with VA requirements when no longer required by HIPAA to be held by the vendor.\nVA Connectivity Requirements\nThe Contractor shall provide each participating facility the capacity to order lab testing and receive results through a secure web-based portal. The Contractor shall show that this portal meets VA requirements for encryption of sensitive patient information. The requirements that VA utilizes for these types of transmission shall be the Federal Information Processing Standard (FIPS) Publication 140-2. The Contractor shall be responsible for transmission of orders, confirmation of orders, test results, and the preventive maintenance of the system. Contractor shall be available to train the Facility s staff on the use of the system at each facility. An alternate method of sending orders and receiving results shall be in place in the event of system down time. A shipping manifest shall be generated that identifies the specimens sent to the reference laboratory, transportation conditions, and testing ordered.\nCERNER is a new VA computer system that will be utilized. The contractor shall ensure they have the ability to interface with CERNER and is operational and validation is complete with full menus complete at the time of contract award.\nThe Contractor shall have an electronic bi-directional interface system. The Contractor shall meet all Cyber Security requirements to establish an interconnection with the VA for transfer of test ordering details and laboratory test results directly from and into the VA computer system via the appropriate LEDI protocol. The interface shall be designed with a single data interface for the Facility which all sites shall utilize. The interface shall allow the generation of manifests to identify the specimens to be sent to the reference lab. Upon receipt of test results, the VA staff shall be able to review/validate test results before release. The Contractor shall be responsible for the purchase of any licenses for middleware products (e.g., Data Innovations) and hardware for any middleware or interface structure.\nIf the Contractor does not have a bi-directional electronic interface already in place, the Contractor shall have the following implemented within three (3) months of the contract award date. Contractor shall assist staff in the updating of the test database by providing all information required to create new test files for the required tests (i.e., sample requirements, shipping temperatures, reference ranges, CPT codes). Interface portal shall be connected and approved, including any required hardware, such as dedicated printers for labels and results. Interface validation shall be completed on the tests that have been updated in the database.\nDue to the difficulties encountered with any major reference laboratory interfacing change or upgrade, Contractor shall temporarily provide a single knowledgeable point of contact for researching correct test information, point(s) of contact for developing, testing, and implementing a client/vendor interface, and then an ongoing point of contact for troubleshooting interface problems. Temporary service shall be in effect until interfacing change or upgrade has been completed.\nThe Contractor shall meet all Enterprise Cyber Security Infrastructure Project (ECSIP) requirements in order to establish an interconnection with the VA for transfer of laboratory test results directly into a VA computer system via the appropriate LEDI protocol. The ECSIP team shall have the ultimate decision on which connection type is appropriate.\nThe Contractor shall provide the following interfacing requirements: Laboratory Information Systems LIS physical connection and translation (drivers) and any required (additional) interface connection license(s) and the Interface shall transmit test results to the host computer via automatic upload. The interface connection shall be tested and verified before putting into use.\nThe reference laboratory shall meet VA information security and Health Insurance Portability and Accountability Account of 1996 (HIPAA) requirements and shall be able to interface with the current or any new interface partner of the Laboratory Information System. The Contractor shall have all users with VA access complete the VHA privacy training prior to starting services.\nCERNER is a new Computerized Electronic Health Record that VA is in the process of transiting to. The Contractor shall ensure they have the capability and are able to interface with this system when it is implemented in addition to VISTA/CPRS that is currently in place.\nPerformance Improvement\nThe Contractor shall comply with the participating Facility Performance Improvement (PI) program as applicable to Pathology and Laboratory Medicine Service (PALMS). PALMS shall monitor the vendor s Test Assay Turn Around Times (TATs) on a quarterly basis. Vendor shall provide a quarterly TAT report for all patient testing requests sent for analysis. Quality Assurance Technologists shall provide a quarterly report to participating facility management teams for review. Contractor PI activities may be directed by the VA facility, VISN or VHA, as well as accreditation or licensing bodies. The Contractor shall abstract, compile and report PI data as requested by the VA. VA Data collection methodology, report format, and reporting deadlines shall be defined by the participating facility. Examples of required PI activities include the VHA Performance Measures/Clinical Practice Guidelines program, and the Joint Commission ORYX or Core Measurement program. It is noted that PI activities are dynamic and subject to change, as driven by current priorities and resources. In all cases, the Contractor shall continually assess for, and act upon, clinical and administrative improvement opportunities. High priority shall be given by the Contractor to the prevention of risk for the patient. The Contractor shall implement process-related internal controls to prevent risk to the veteran. VA monitoring for continuous compliance with Joint Commission standards shall be directed by VA staff and communicated to the Contractor through the COR. VA aggregate and/or practitioner-specific data collected by the VA shall be provided to the Contractor in accordance with established reporting schedules. VA measures related to contract compliance shall be identified by the COR\nInformation and Records Management\nThe participating Facility Information Management plan shall be followed by the Contractor. Documentation and record keeping shall be in accordance with the Facility policies and procedures. Strict adherence to all documentation related to the performance of invasive procedures shall be maintained. Identified medical record delinquency data shall be forwarded to the Contractor by the participating facility\nAutomated Data Processing (ADP) Security/HIPPA and Excluded Individuals\nThe VA shall provide access to the Veterans Health Information and Technology Architecture (VISTA) for Contractor employees. All Contractor employees accessing the VISTA system shall be required to sign and abide by all VAAAHS security policies and applicable VA confidentiality statutes, 38 U.S.C. Â§5701, 38 U.S.C. 7332, and the Privacy Act, 5 U.S.C. Â§552a. Background security investigations shall be completed before access to VISTA may be granted\nHealth and Human Service Office of Inspector General (HHS/OIG): To Ensure that the individuals providing services under the contract have not engaged in fraud or abuse regarding Sections 1128 and 1128A of the Social Security Act regarding federal health care programs, the Contractor is required to check the Health and Human Service Office of Inspector General List of excluded individuals/entities on the OIG Website (www.hhs.gov/oig) for each person providing services under this contract. Further, the Contractor is required to certify in its proposal that all persons listed in the Contractor s proposal have been compared against the OIG list and are not listed. During the performance of this contract the Contractor is prohibited from using any individual or business list on the List of Excluded Individuals/Entities\nTelecommunication Interface Requirements\nIn order for contract performance to begin within the shortest time possible after contract award, Contractor must already possess a current VA nationally approved Business Partner Gateway (BPG) Interconnection Security Agreement (ISA) and Memorandum of Understanding (MOU) and have an integrated system approach to facilitate and streamline all aspects of specimen ordering, testing, and reporting. As such, the Contractor shall develop and program an interface connection to electronically transmit orders, specimen status, and test results between the Contractor s host computer system and the Government s host computer system (VistA). (NOTE: A subcontractor may be utilized to outsource the connectivity solution.)\nThe VistA host computer system supports a Universal Interface (UI) and a Generic Instrument Manager (GIM). The GIM is a commercial hardware and software product that provides electronic connection between the Contractor s host computer and the Government s host computer. The configuration must provide the required security of the Government host computer system. The actual electronic connection between the GIM and the Contractor s host system is of the Contractor s choosing. The initial and continual expense of the electronic message connectivity and maintenance shall be borne by the Contractor throughout the performance of the contract.\nContractor shall provide, install, and if necessary, remove, all required telecommunication equipment, hardware, software, and related consumable supplies to support the transmission of electronic data to all sites referred to herein. This may include, but is not limited to:\nGeneric Instrument Manager (GIM) for the interface connection\nShipping list printers\nBar-code printers\nBack-up result printers connected directly to Contractor s computer system\nAny required communication lines\nSoftware to receive and send orders, display status of and/or test results\nConsumable supplies to maintain the operation of the equipment listed above, e.g., toner, etc.\nContractor shall be responsible for all annual recurring costs associated with support and maintenance of the Generic Instrument Manager (GIM) system including all GIM equipment, software, and instrument connections. The Generic Instrument Manager will be located in a government secured area. The Contractor shall coordinate with the respective Government Information Technology Department to access the GIM.\nThe Contractor shall conduct preventive maintenance and repair of Contractor furnished hardware, software, and associated communication lines. In addition, throughout the performance period of the contract, the Contractor shall repair or replace any malfunctioning hardware or software.\nAll electronic messaging between the two (Contractor and Government) host computer systems using the GIM shall utilize VistA Health Level Seven (HL7) V1.6 technical specifications. Health Level 7 (HL7) is a registered trademark of Health Level Seven, Inc, a Standards Developing Organization accredited by the American National Standards Institute to author consensus-based standards. Information regarding HL7 transmission protocols may be accessed through the Health Level Seven, Inc website, www.HL7.org.\nVistA Laboratory Electronic Data Interchange (LEDI): identifies Government-specific content and encoding tables to be used with HL7 message protocol conventions. The LEDI specification follows very closely the HL7 V2.3.1 standard. LEDI identifies encoding tables and HL7 message protocol conventions.\nLEDI also identifies to the commercial reference laboratory contractor shipping lists containing required specimen demographics and requested tests to be performed. This list will be provided in printed format during the implementation period. This information is also available in electronic HL7 format if required.\n(LEDI) software will provide a HL7 acknowledgement for the receipt of tests results from the contractor. In the event that electronic communication is disrupted, the contractor shall provide hard copy of specimen results upon demand. The hard copy must contain Government s assigned specimen identification where specimen identification is defined as a unique Government-assigned number that is associated with each specimen. This specimen identification number will appear on the test order form, on the specimen label and on the shipping manifest.\nThe Contractor shall provide the Government with specimen status in response to electronic and verbal query. Upon test completion, a formatted HL7 message containing specimen test results with Government s assigned specimen identification shall be returned to the requesting medical center.\nContractor shall address within two hours of initial inquiry, interface connection questions where information is required to update, maintain, and support the services of the host-to-host linkage between the Government and the Contractor.\nContractor shall provide in-service training required for the routine loading and care of printers and other hardware located on-site. The training will ensure that Government staff is capable of performing routine servicing of hardware.\n\nPOLICIES, REGULATIONS, AND COMPLIANCE STANDARDS\nPOLICIES AND REGULATIONS\nPolicy/Handbooks:\nVHA Handbook 1100.17: National Practitioner Data Bank Reports - https://www.va.gov/vhapublications/ViewPublication.asp?pub_ID=2135\nVHA Handbook 1100.19 Credentialing and Privileging - https://www.va.gov/vhapublications/ViewPublication.asp?pub_ID=2910\nVHA Handbook 1907.01 Health Information Management and Health Records: https://www.va.gov/vhapublications/ViewPublication.asp?pub_ID=3088\nPrivacy Act of 1974 (5 U.S.C. 552a) as amended: http://www.justice.gov/oip/foia_updates/Vol_XVII_4/page2.htm\nVHA Handbook 1106.01: Pathology and Laboratory Medicine Service (P&LMS) Procedures: https://www.va.gov/vhapublications/ViewPublication.asp?pub_ID=3169\nConformance Standards\nContractor shall maintain full compliance with applicable Federal and State regulations. All services provided under this contract shall be performed in conformance with the National Fire Protection Agency (NFPA) 99- Health Care Facility Code, Occupational Safety and Health Administration (OSHA), HIPAA, and other applicable national, state, and local regulatory agencies. Contractor shall maintain Clinical Laboratory Improvement Act (CLIA) certificate of accreditation, and The Joint Commission (JC) and the College of American Pathology (CAP, if required) accreditations. A copy of the CLIA certificate shall be provided to the participating Facility when requested\nContractor s Laboratory Director shall be a licensed American Board of Pathology certified pathologist. The Contractor shall make sure employees have current and valid professional certifications before starting work under this contract. All contractor personnel shall meet the performance characteristics for accuracy and precision as defined by the 1988 Clinical Laboratory Improvement Act (CLIA) and the Clinical and Laboratory Standards Institute (CLSI) and maintain required licenses. The Contractor shall maintain current licenses and certificates and provide copies of such to VA upon reasonable written request\nJoint Commission Compliance Standards\nAll applicable VA and VHA policies, procedures and directives shall be followed by the Contractor. The Contractor shall continuously meet or exceed all Joint Commission Hospital standards and provide oversight of care, treatment and services provided through contractual agreement standard LD.04.03.09. The patient population treated within the covered areas consists of veterans with varying physical, psychiatric, and psychological needs. Their conditions are in many cases, directly related to the individual s service to this country. Contract personnel shall provide compassionate care with respect for the special needs of the veteran population served. Care delivered shall reflect the VA Medical Centers mission, vision, and values:\nMISSION: Honor America s veterans by providing exceptional health care that improves their health and well-being.\nVISION: VHA shall continue to be the benchmark of excellence and value in health care and benefits by providing exemplary services that are both patients centered and evidenced based. This care shall be delivered by engaged, collaborative teams in an integrated environment that supports learning, discovery, and continuous improvement. It shall emphasize prevention and population health and contribute to the nation s well-being through education, research, and service in National emergencies.\nVALUES: VHA s five core values are Integrity, Commitment, Advocacy, Respect, and Excellence. They define our culture and how we care for our Veterans. They affect outcomes in our daily in\nSPECIAL CONTRACT REQUIREMENTS\nAWARD SPECIFIC INFORMATION\nModifications\nAll modifications shall be given at minimum 60 days for any change takes place. Modifications shall not be effective until executed.\nModifications that change the terms and conditions of the contract shall be bi-lateral.\nModifications that are administrative in nature may be completed unilaterally by the Government to update attachments, points of contacts, etc.\nPricing\nThis is a Firm Fixed Price (FFP) agreement with estimated quantities.\nPricing shall not change from the awarded pricing.\nVariable Priced Tests shall not be included. They will either need to be provided a FFP or not orderable through this agreement.\nPricing shall be determined and established at the time of award for ordering periods. Pricing shall not change.\nTests and Reflex Tests\nThe VA has estimated the quantity of tests that will be needed for the entirety of the agreement, including all ordering periods. Quantities may increase or decrease based on the Government s needs. Quantities are not guaranteed.\nAll tests and reflex tests shall be listed in the award with established test codes and pricing.\nOnly the tests and test codes listed in the award are authorized.\nNew Tests:\nmay be added to the award through a bi-lateral modification.\nshall not be utilized until a bilateral modification is executed.\npricing shall not change for any test replaced due to a test code/description change.\nTests Not Listed in the Award\nTests not listed in this award with the assigned test code/description are not authorized.\nAny test not listed or authorized shall follow a separate process unrelated to this agreement or through VA Community Care.\nContractor shall not process any test not listed in the award nor request payment for tests not listed through this agreement. Contractor risks non-payment of any test not authorized.\nEstablished Process for Non-Listed Test Codes/Descriptions (Non-Contracted):\nContractor shall set up a Non-Contracted Account Number\nAll Non-Contracted Tests shall not be processed without proper authorization prior to the test being processed.\n\nEMPLOYMENT AND LIABILITY\nThis is a non-personnel services contract. The Contractor shall be responsible for protecting the personnel furnishing services under this contract. To carry out this responsibility, the Contractor shall provide the following for these personnel, which includes worker s compensation, professional liability insurance, health examinations, income tax withholding and social security payments. The parties agree that Contractor personnel without formal appointments shall not be considered VA employees for any purpose and shall be considered employees of the Contractor\n\nINFECTION CONTROL\nContracted patient care activities shall be integrated into the participating Facility Infection Control program, and contract staff shall adhere to the Facility Infection Control policies and procedures. The Facility Infection Control Plan shall identify for the Contractor how risks shall be identified, methods to be used to reduce risk, identification and reporting of community-acquired and nosocomial infections, and data collection and reporting requirements. Reports of surveillance, control, prevention, and monitoring activities performed by the part Facility shall be provided, on a routine basis, to the Contractor.\n\nPATIENT SAFETY\nPatient safety shall be a primary focus of the Contractor including compliance with all applicable patient safety goals. The participating Facility shall inform the Contractor of all applicable Sentinel Events or other Patient Safety Alerts received by the Facility. For every applicable alert, the Contractor shall take the necessary steps to redesign processes to prevent occurrence and provide written feedback to the Contracting Officer Representative (COR) describing prevention actions taken. All events related to patient injury, medication errors, and other breeches of patient safety shall be documented utilizing the Contractor s format and reported to the COR utilizing the part Facility Incident Report. The Facility shall provide the Contractor with the Sentinel Event definitions in the start-up phase. The Contractor shall verbally notify the Facility COR immediately when a Sentinel Event has occurred, which is to be followed by written notification within one (1) business day or sooner if requested by the medical center. The Facility shall determine when a Root Cause Analysis (RCA) is required of the Contractor. The Contractor shall conduct all Root Cause Analysis according to the Facility policy and within established time frames (45 days). Completed RCAs shall be provided to the Facility COR.\n\nPATIENT RIGHTS\nProtection of all patients rights is of highest priority. Patient privacy and confidentiality shall be maintained at all times. Computer access shall be granted on a need-to-know basis, and security of computerized information shall be maintained at all times. No patients shall be subject to any research activity without his fully informed consent, subject to study approval by the Investigational Research Board (IRB). The Contractor shall abide by the participating Facility Code of Ethics, which addresses marketing, admission/transfer/referral/discharge processes, and billing issues. The Contractor and the patient care service provided shall be included in the participating Facility data collection activities related to patient and family complaints and satisfaction issues. Care provided shall respect and integrate the patient s beliefs, values, and cultural influences\n\nGOVERNMENT RESPONSIBILITIES\nCONTRACT PERFORMANCE MONITORING\nContractor's employee(s) shall report to the Laboratory Central Processing area, upon arrival at the VA for specimen pickup.\nMonitoring of contractor s performance shall be demonstrated through clinical and administrative record reviews. COR will be responsible for verifying contract compliance. Contracting Officer's Representative(s) (COR) will designate appropriate VA personnel to monitor services through one or a combination of the following mechanisms:\nDepartments being served will monitor Contractor performance to ensure that services called for in the contract have been received by VA in a timely manner. Any incidents of Contractor noncompliance as evidenced by the monitoring procedures will be forwarded immediately to the Contracting Officer.\nDocumentation of services performed will be reviewed prior to certifying payment. The COR will perform periodic spot checks and document with the using service to ensure records monitoring. VA will pay only for services actually provided, and in strict accordance with the Price/Cost Schedule. Contract monitoring and recordkeeping procedures will be sufficient to ensure proper payment and allow audit verification that services were provided.\nDepartments being served, through the COR(s), will provide a written statement annually to the Contracting Officer to include a summary of Contractor actions and a statement that all requirements of the contract have been fulfilled as agreed. This summary evaluation will be submitted 45 days prior to expiration of contract (and/or prior to ordering periods, if applicable).\n\nQUALITY ASSURANCE MONITORING\nContractor shall maintain a Quality Assurance Program related to Reference Laboratory services covered under this contract.\nContractor shall also participate in a joint quality assurance surveillance program (QASP) with the Government facilities. This program must minimally address the quality aspects representative to the testing process, i.e., pre-analytical, analytical, and post-analytical variables and include a description of monitoring and evaluation activities. There must be a mutually agreed upon procedure for responding to issues, problems and/or concerns identified by the Government with details as to whom and in what timeframe the matters will be reconciled. The issues that may need to be addressed may be general in nature or specific to an incident or event. The contractor will meet or communicate with the facility/VISN staff for process review and improvement of contract performance on an as needed basis.\nCopies of licensure/certifications are also required to be submitted upon request by the VA.\n\nPERFORMANCE STANDARDS\nLicensing, Accreditation, & Certification\nPerformance Requirement: Contractor shall maintain and provide CLIA Certification, CAP Accreditation, or equivalent; along with applicable OSHA, Federal, and State Laws for all laboratories, including any subcontractors.\nStandard: Proper certifications shall be kept up to date for the entire performance of this agreement. This includes all ordering periods.\nAcceptable Quality Level (AQL): 100% Meets Standard, no deviations are authorized.\nSurveillance Method: Periodic Sampling\nFrequency: Contractor shall provide all requested Licenses, Accreditations, and Certifications upon request of the Government at any time for all laboratories, to include all subcontractors.\nTechnical Quality\nPerformance Requirement: Produce high-quality, consistent access to reports, test code changes, errors in technical transmission issues.\nStandard: Meets quality requirements.\nAcceptable Quality Level (AQL): 95% Meets Standard\nSurveillance Method: Quarterly Review\nFrequency: COR to review issues with interfacing and notifications of test code changes, issues with test code results.\nTimeliness\nPerformance Requirement: Processes specimens and report test results within the stated turn-around-times.\nStandard: Timely courier pick-ups, specimen processing and reporting of all test results.\nAcceptable Quality Level (AQL): 90% Meets Standard\nSurveillance Method: Periodic Sampling\nFrequency: COR will review monthly reports\nTest Accuracy\nPerformance Requirement: Contractor shall provide accurate testing in accordance with the tests, test codes, test descriptions, specimen processing, and test results.\nStandard: Number of modified test results, not due to incorrect requisition information from referring lab.\nAcceptable Quality Level (AQL): < 0.02% of all patient results received.\nSurveillance Method: Monthly review\nFrequency: COR will review monthly reports.\nTransportation & Sample Integrity\nPerformance Requirement: Transportation and Quality standards outlined in the Performance Work Statement (PWS).\nStandard: Ensures integrity of samples during transportation to the performing laboratory.\nAcceptable Quality Level (AQL): < 3 lost specimens.\nSurveillance Method: Monthly review.\nFrequency: COR will review monthly reports and courier pick-up logs.\nAnatomic Pathology Random Review\nPerformance Requirement: Contractor shall perform retrospective case review.\nStandard: Staff pathologist to provide case reviews of 10% of all cases for pathology, surgical, cytology, hematopathology, mohs, and fine needle aspirate, etc.\nAcceptable Quality Level (AQL): 100% review and documenting of 10% of all cases.\nSurveillance Method: Monthly review\nFrequency: Contractor shall provide a monthly report to each facility COR providing all results of each review completed.\nBilling and Invoicing\nPerformance Requirement: Contractor shall ensure only tests listed in the award (test codes and descriptions) are billed through the award account. Contractor shall ensure that they meet all invoicing and billing requirements established in the award.\nStandard: Proper and correct invoicing.\nAcceptable Quality Level (AQL): 90%\nSurveillance Method: Monthly review.\nFrequency: Contractor shall submit on-time invoices with all required information monthly as established in this award.\nTracking Purchase Card Transactions\nPerformance Requirement: Contractor shall follow the procedures in Attachment 7\nStandard: Proper and correct tracking and notification of test results delivery and payment\nAcceptable Quality Level (AQL): 90%\nSurveillance Method: Monthly Review\nFrequency: Contractor shall submit monthly tracking spreadsheet as established in Attachment 7\n\nCONTRACT INCREASES UP TO 20% OF TOTAL CONTRACT VALUE\nDue to the unpredictable nature of the quantities and types of tests that will be required, any estimations will fall short of accurate. Therefore, the VA reserves the right to increase the total value of the contract up to no more than 20% of the total contract value by increasing the estimated quantities of tests required, and/or adding new tests to the list via a supplemental agreement in accordance with FAR 52.212-4. These modifications will occur on an estimated quarterly basis.\n\nINVOICING INSTRUCTIONS\nInvoice requirements and supporting documentation: Supporting documentation and invoice must be submitted no later than the 20th workday of the month for the month prior. Subsequent changes or corrections shall be submitted by separate invoice. In addition to information required for submission of a proper invoice in accordance with FAR 52.212-4 (g), all invoices must include:\nName and Address of Contractor\nInvoice Date and Invoice Number\nContract Number and Purchase/Task Order Number\nDate of Service\nInvoices shall not include any PII such as full name, social security number, or date of birth.Â\nAttached Excel spreadsheet Reference Lab Invoice Summary for each month with the total quantity for the corresponding invoice (this shall include every test in order as they appear in the award, even if the total is zero for that month).\nInvoices shall include the correct PO.\nInvoices shall be submitted electronically through Tungsten Services and be certified by VA COR for payment.\nAny test code names and/or quantities on a contract invoice that was paid for using a purchase card transaction will cause the invoice to be rejected in it s entirety.\nAny test code names and/or quantities that were not able to be provided due to specimen integrity failure will cause the invoice to be rejected in it s entirety.\nWhen invoicing, prior to the test name being updated via contract modification, the Contractor shall reference both the previous test code name and new test code name on the invoice.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25025Q0255","place_of_performance":{"zip":"49037","city":{"name":"Battle Creek"},"state":{"name":"MI"},"street":"Department of Veteran's Affairs","country":{"code":"USA","name":"UNITED STATES"},"street2":"Battle Creek VA Medical Center 5500 Armstrong Road"},"product_service_code":"Q301"}],"due_at":"2025-02-25T17:00:00Z","due_date":"2025-02-25","closes_at":"2025-02-25T17:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","state":"MI","county":"26025","county_name":"Calhoun County","city":"2605920","city_name":"Battle Creek","country":"USA","state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-23T01:25:14.149439Z","principal_notice_id":"d57430295cf9497599f6cc793c16f04f","description":{"text":"?.## PERFORMANCE WORK STATEMENT\nVETERANS INTEGRATED SERVICE NETWORK (VISN) 10\nBATTLE CREEK & WYOMING CBOC REFERENCE LABORATORY TESTING SERVICES\nOverview\nThe Contractor shall enter into an Indefinite-Delivery Indefinite Quantity Contract (IDIQ) with the Battle Creek VAMC and Wyoming CBOC in Michigan to provide reference laboratory testing for the patients enrolled in the participating facilities. Contractor shall provide all necessary supplies to provide reference laboratory testing services for the participating facilities below and all support facilities of the BCVAMC. The IDIQ term shall be five (5) years. This is a firm-fixed price IDIQ. The estimated quantities are for each test per year.\nBackground\nDepartment of Veterans Affairs, Veterans Health Administration (VHA), VISN 10, Battle Creek VAMC and Wyoming CBOC, requires the services of a contractor for reference laboratory testing services. The contractor shall provide reference laboratory testing for the patients enrolled in the participating facilities. Contractor shall provide all necessary supplies to provide reference laboratory testing services for both the participating facilities below and all support facilities.\nReference Laboratory Services include at minimum specimen preparation and storage; transportation of clinical laboratory specimens; microbiology cultures and stocks; performance of analytical testing; reporting of analytical test results; consultative services; and reports as required by this document.\nPlaces of Performance\n\nBattle Creek VA Medical Center\n5500 Armstrong Road\nBattle Creek, MI 49037\nUSA\n\nAND\n\nWyoming VA CBOC\n5838 Metro Way SW\nWyoming, MI 49519\nUSA\n\nSUPPORTING FACILITIES\nContractor shall ensure that supplies are provided as required by the Veterans Affairs Medical Center (VAMC).\nA VA courier will collect specimens from support facilities and those specimens will be collected by the contractor courier from their assigned participating facility on the dates and times listed in Section 5 below.\nGovernment reserves the right to add or remove supporting facilities as necessary.\n\nCONTRACTOR RESPONSIBILITIES\nOVERVIEW\nThe Contractor shall provide at minimum:\nAll necessary supplies for specialized specimen collection, testing, transport, and packaging, shipping kits\nSupplies shall be provided as the medical centers require additional supplies to support patient testing needs. (Government will provide Serum 2 supplies)\nCourier (not shipping) and flight services for the transportation of the specimens\nFlights to be made out of an airport that provides the best efficiency in getting the specimens to the contractor while maintaining specimen integrity. Contractor is responsible for specimen integrity once specimen leaves the VA facility.\nCourier service for pick-up of patient samples from facility s laboratory, shall be provided Monday Saturday and pick-up times required by the site are identified below:\nBattle Creek VAMC 1 pickup Mon-Sat between 6:00PM and 7:00PM\nWyoming CBOC VAMC 1 pickup Mon-Sat between 6:00PM and 7:00PM\nDry ice (if required)\nChain of custody forms (if required)\nSpecimen transport request forms\nReference laboratory testing and reporting with current reference ranges.\nSecured web-based portal system, Intranet Laboratory Electronic Data Interchange (LEDI) system, and printer equipment including compatible ORACLE EHRM equipment.\nContractor must have interchange with the VA EHR computer system which will be installed during this contract at the time of award.\nContractor shall have a single national coding system.\nContractor shall utilize one test code per test nationally.\nContractor shall utilize approved Patient Identifiers\nCustomer telephone service 24/7 365 days a year\nContractor shall have an electronic test menu submission system as the preferred test submission avenue with limited specialty tests to be submitted on paper test submission forms.\nShipping manifest\nMonthly report to the VAMC to include, at a minimum, through an appropriate electronic format: (no PII/PHI can be included)\nTests ordered.\nNumber of unsatisfactory specimens\nNumber of tests performed in current month; and\nCalendar year-to-date with Current Procedural Terminology (CPT) code and cost. Reports to include all testing ordered for the calendar year.\nThis report shall include pricing per account number for each participating site.\nProvide and maintain a user-friendly public website which allows easy reference for researching test information (test number/CPT coding, patient preparation, test utility, result interpretive guidelines. For tests not listed on public website Contractor shall provide access to their database for client research test information; and\nRoutine test results to the participating ordering facility within twenty-four (24) hours following test completion, except when specimens are picked up the day before a weekend or holiday (in which case the results shall be provided the following business day). The Contractor shall notify the facility within two (2) hours of any critical values or results.\nContractor s billing and utilization reports shall run from the first day of each month through the last day of each month. For Example: January 1 January 31, February 1 28 or 29(if leap year), and June 1 June 30.\nQUALIFICATIONS\nLicensing and Accreditation\nOnly fully licensed/accredited laboratories actively engaged in providing the specific services and laboratory testing outlined in this solicitation shall be considered. The Contractor/Subcontractor shall have all licenses, permits, accreditation and certificates required by law and be provided to the CO/COR at the time of award. The reference laboratory shall be licensed/accredited by the College of American Pathologists (CAP) or The Joint Commission (TJC), or any other licensing and/or Accreditation in order to perform the required testing listed in this PWS. In addition, the laboratory must be certified as meeting the requirements of the Department of Health and Human Services Clinical Laboratory Improvement Act of 1988 (CLIA).\nThe Contractor shall provide a copy of all relevant permits/licenses and certifications inclusive of all sanctions current or pending throughout the United States of America prior to contract award. In addition, the Contractor shall be responsible for providing written guarantee or evidence that all Subcontractors have appropriate licensure and accreditation to perform tests that the primary Contractor cannot perform prior to contract award and as requested by the Contracting Officer (CO). All proposed Subcontractor changes during the contract performance period must have prior approval by the CO. Changes to the requirements shall be addressed by bilateral modification.\nContractor Personnel assigned by the Contractor to perform the services covered by this contract shall be eligible to provide the services of this contract and licensed in a State, Territory, or Commonwealth of the United States or the District of Columbia. All licenses held by Contractor personnel working on this contract shall be full and unrestricted licenses. Contractor Personnel assigned by the Contractor to work under this contract shall be licensed by the governing or cognizant licensing board.\nContractor policies and procedures shall comply with Health Insurance Portability and Accountability Act (HIPPA)\nThe Contractor shall notify the Contracting Officer in writing of all malpractice investigation or licensure or certification suspension that concerns the Contractor or Contractor personnel, or any discovery of any disciplinary action taken against laboratory(ies) performing under the contract within 24 hours of notification of an investigation or suspension.\nContractor Personnel\nThe Contractor shall maintain current accreditation and notify the Contracting Officer of all lapses in state license, Clinical Laboratory Improvement Amendments (CLIA) certification, or clinical pathology certification. The Contractor shall provide access via website or email upon request a copy of the renewed licenses/certificates before expiration.\nLaboratory Director shall be a licensed American Board of Pathology certified pathologist or appropriately certified bio-analyst.\nThe Contractor must have at least three years of experience providing laboratory services and must have at least one-year experience in transporting biomedical materials.\nCLIA certifications shall include approval for testing for the following disciplines/subdisciplines and effective dates of approval for each disciplines/subdisciplines\nHistocompatibility (010)\nBacteriology (110)\nMycobacteriology (115)\nMycology (120)\nParasitology\nVirology (140)\nSyphilis Serology (210)\nGeneral Immunology (220)\nRoutine Chemistry (310)\nUrinalysis (320)\nEndocrinology (330)\nToxicology (340)\nHematology (400)\nImmunohematology ABO Group & Rh type (510)\nImmunohematology Antibody Detection (transfusion) (520)\nImmunohematology Antibody Detection (non-transfusion) (530)\nImmunohematology Antibody Identification (540)\nImmunohematology Compatibility Testing (550)\nHistopathology (610)\nOral Pathology (620)\nSurgical Pathology\nMolecular Biology\nCytology (630)\nRadiobioassay (800)\nCytogenetics (900)\nAny changes to the CLIA certifications should be communicated to the facility within 24 hours. This also applies to the subcontractors.\nThe Contractor is required to provide all technical advisory/recalls/alerts, prior to or simultaneously with field alerts, should be forwarded to the designated individuals determined at contract award.\nThe Government reserves the right to refuse the use of a subcontractor who fails to comply with evidence of accreditation(s) or licensures(s)\nSPECIMEN PREPARATION\nContractor shall supply each Government facility with its commercial laboratory reference test manual to ensure that the collection and storage of specimens are in accordance with Contractor s requirements.\nContractor shall provide all materials necessary to collect and preserve specimens that are destined to the commercial reference laboratory for testing. These materials include those items that are dictated by and in compliance with the collection requirements of the commercial reference laboratory.\nIf a medicolegal specimen is submitted, the Contractor shall provide its own special forms and special handling procedures to maintain a valid chain-of-custody possession and develop the formal documentation necessary for that purpose. Contractor s testing personnel who performed the analysis may be required to provide Court testimony. Contractor testimony shall be provided as required at no additional expense to the Government.\nContractor shall be responsible for storing specimens in such a manner to ensure the integrity of the specimen.\nSPECIMEN TRANSPORATION\nContractor shall provide transportation of primarily biomedical materials that include patient specimens, cultures, and stocks, originating from Government facilities and destined to the contracted commercial reference laboratory.\nThese specimens are classified as Hazard Materials Class 6, Division 6.2 and are defined in 49 CFR Part 173.134 as those materials that contain or could contain etiologic agents. Transportation shall be done in such a manner that the safety and integrity of the biomedical material is maintained.\nTransportation/Courier Services for pick-up of patient samples from the Government facilities listed in this document shall be provided by the contractor.\nThe Government reserves the right to adjust the courier pick-up days and times as necessary, provided a two-week notice has been provided and acknowledged by the Contractor at no additional charge to the Government.\nThe Government reserves the right to add or remove courier pick-up locations provided a two-week notice has been provided and acknowledged by the Contractor at no additional charge to the Government.\nProcessing shall begin immediately upon receipt at the testing site and results provided within the laboratory established turnaround times.\nCourier services shall be available seven (7) days a week, including Federal holidays as required. A list of Federal Holidays can be found in the following Link: Federal Holidays (opm.gov)\nContractor shall provide all necessary supplies for biomedical materials to be transported from the VA medical facility to the performing laboratory. These supplies shall include at minimum:\nShipping and packaging containers. Packing material must be capable of maintaining temperature requirements for specimens until they reach the Contractor s laboratory.\nRequired labels and packaging materials for shipping specimens via courier that are infectious, or etiologic agents, in accordance with appropriate requirements of 42 CFR Part 72, 49 CFR Parts 171 and 173, and the Dangerous Goods Regulations of the International Air Transport Association (IATA) consistent with current regulatory updates.\nTest request forms, preprinted with the appropriate Shipping Section details and account information.\nTest request forms for specialized testing (i.e., cytogenetics, tissue, etc.).\nPrinter and printer supplies including paper, labels, and toner/ ink cartridges, in sufficient quantities to perform work under this contract.\n\nSPECIMEN TESTING\nContractor shall ensure test sample integrity is maintained at all times from the time they are picked up from the participating facility and delivered to the processing laboratory.\nContractor shall provide the full range of laboratory testing capabilities to execute all required test orders as annotated in this agreement.\nAll the testing should be performed on the Contractors premises or within the Contractor s network labs (as official or qualified subcontractor). Under no circumstance should the contractor allow any patient information to cross the US borders. Contractor referral to the secondary laboratory or subcontractor should be kept to a minimum for control and uniformity purpose. Subcontractor should be held to the same quality standard as specified in the contract.\nContractor shall make available the following test information:\nRequisition form requirements\nAlphabetized test name list\nTest order code\nSpecimen collection and preservation requirements\nTest method employed (indicate if testing performed in duplicate) and interpretations\nTest reference intervals adjusted for age, sex, or race, when required\nTest specific sensitivity, specificity, and interferences, when required\nResult code\nTest critical values if any\nPolicy for critical value notification\nCPT coding\nTest turnaround times (minimum and maximum times indicated); where the turnaround time is defined as the time between receipt of specimen by the Contractor and receipt of results by a government facility.\nSchedule of test performance (specific days of week indicated)\nLocation of test performance by test name (i.e., name of primary laboratory, name of separate branch/division of primary lab, name, and address of secondary (sub-contracted) laboratory must be cited)\nContractor shall notify the Site Contracting Officer Representative (COR) for each participating facility of any test submitted to be processed that does not match this agreement prior to being tested so that the appropriate process can be followed to process the test.\nAll reference laboratory testing is preferred to be tested using test methods that are FDA approved.\nAny non-FDA approved method being performed shall have a disclaimer and documented validation plan.\nUpon request, the validation plan and validation results shall be made available to the COR or designee.\nContractor shall ensure the accurate and timely performance of laboratory testing services on all tests within this agreement.\n\nSPECIMEN RETENTION\nAll anatomic pathology materials (e.g., histology blocks, slides, or other diagnostic material) generated by the VA shall be returned within 7 days after final diagnosis is reported.\n\nTEST RESULTS & REPORTS\nTest Results:\nIf the Contractor is unable to perform the test due to issues with the specimen integrity, the Contractor shall inform the VA as soon as possible, via email to the designated COR, with a maximum time of 24-hours of receipt of the specimen.\nOnce testing is completed, the laboratory results shall be transmitted via secured web-based portal system or the LEDI system to each participating facility via VAMC VISTA/CERNER computer system and printer equipment provided by the Contractor that will be located at each participating facility.\nAlternate methods of reporting results in the event of electronic system failure may include:\nElectronic delivery of all reports is preferred.\nFaxed, please verify fax number prior to sending patient results as fax numbers are subject to change:\n269-966-5483\nAll test results provided by the Contractor/subcontractor shall contain at minimum the following:\nTwo (2) full patient identifiers, one of which is patient s full name\nPhysician s name\nTesting facility name and address\nClinical Laboratory Improvement Amendments CLIA number (if requested)\nAccount number\nDate/time specimen was collected\nDate/time specimen was received\nDate/time test was reported\nContractor generated Laboratory Accession Number\nVA generated Laboratory Accession Number\nTest ordered\nTest result\nFlagged abnormal results\nReference ranges\nType of specimen\nAny additional comments related to test provided by submitting lab\nAny other information the laboratory has that may indicate a questionable validity of test results; and\nUnsatisfactory specimens shall be reported with regard to its unsuitability for testing.\nCorrected reports shall be issued in accordance with accreditation requirements.\nThe Contractor shall return representative slides, anatomic, hematologic, etc., for quality control review when requested. Quality control slides shall represent duplicate copies of original slides prepared by the Contractor from permanent tissue blocks. The Contractor shall provide quality control slides to the facility or clinics at the same time the Contractor submits the final reports. The Contractor shall prepare additional blocks and slides, in quantities specified by the facility for review by pathologists. For malignant cases, the Contractor shall call results to the submitting facility, and prepare paraffin blocks and slides for review by the Joint Pathology Center (JPC) or other Government Pathology Organization (GPO). For benign cases, the Contractor shall prepare slides for review by the facility. Upon provision of sample slides by the facility, the Contractor shall provide interpretation of sample slides. The sample shall include, at a minimum, breast biopsy, thyroid biopsy, mastectomy with nodes, colon resection, lymph node biopsy, and gynecology and non-gynecology cytology.\nThe Contractor shall store all blood and fluid specimens after all testing has been completed in the event repeat or add on testing for one (1) week at conditions that shall maintain sample viability. Upon request, samples shall be returned to the collecting VA facility via courier at conditions that shall maintain sample viability, at no additional charge to the VA. All anatomical pathology specimens (i.e., slides, blocks, etc.) shall be returned within two (2) weeks of test completion.\nReports:\nAll Reports shall run from the 1st day of each month through the last day of each month. For Example: January 1 January 31, February 1 28 or 29 (if leap year), and June 1 June 30.\nContractor shall prove consultative services that are consistent with the services offered to other contracted customers without compensation. These services may include consultations by laboratory professionals or experienced physicians on test or methodology selection or test result interpretation.\nContractor shall provide access to online statistical analysis and metrics of the Government facilities test utilization reports to assist in the monitoring of ordering trends and utilization patterns. The contractor shall make recommendations to the facilities on mechanisms to reduce their costs and provide recommendations for improvements in testing and results.\nTest utilization (number and cost)\nTrending of test utilization (number and cost)\nLine graph AND\nTotal number\nTest utilization by provider\nContractor shall provide a cumulative workload summary report of tests performed. The summary must include the facility account number, the test name, the test ordering code, monthly test volume, year-to-date test volume, unit test cost, monthly test expenditures and year-to date test expenditures, the VA and Test Lab generated accession numbers, and the name and address of the testing laboratory (contractor and subcontractor).\nA copy of the report shall be delivered electronically to the Contracting Officer and COR by the 10th of the month following the close of the reporting month.\nAll reports shall be submitted in electronic spreadsheet format and have the capability to sort by four (4) different methods:\nFacility account number\nTest names listed alphabetically\nTest names listed in order of year-to-date test frequency (highest to lowest)\nTest names listed in order of year-to-date total test cost (highest to lowest)\nAdditional Administration Requirements / Reports\nThe Contractor shall provide an updated copy of the Excel spreadsheet Reference Lab Invoice Summary to the Contracting Officer, COR by the 10th of the month following the close of the reporting month. The Contractor shall update the quantities of tests invoiced during the prior month in this spreadsheet.\nContractor shall provide a monthly listing of any tests listed in Section D, Attachment 2 entitled Price-Cost Schedule - Battle Creek and Wyoming CBOC Reference Labs that 1) are no longer performed by contractor or 2) the test name is updated. The Contractor shall highlight the rows RED in the Excel Spreadsheet Declining Balances Monthly Test Tracker for any test codes that are no longer performed by the Contractor or have updated test names and make a note in the Notes column. These tests will be either removed or updated via a supplemental agreement in accordance with 52.212-4. When invoicing, prior to the test name being updated via contract modification, the Contractor shall reference the previous test code name and new test code name on the invoice.\nThe Contractor shall make all reasonable effort to notify the VA that a test ordered against the contract is not listed in Section D, Attachment 2, in order to avoid an unauthorized commitment.\nFor tests that are ordered that are not listed in Section D, Attachment 2, the Purchase Card Procedures in Section D, Attachment 7 entitled Purchase Card Procedures for VA and Contractor shall be utilized. These procedures include the requirement that the Contractor shall provide an updated Excel Spreadsheet, Purchase Card Transactions, that tracks the test name and/or test ordering code, quantity of each test performed, and proposed pricing.\n\nQUALITY REVIEW\nContractor shall provide the following:\nIn accordance with VHA Handbook 1106 a 10% retrospective quality management peer review shall be completed. This review shall be completed by a second pathologist on at least a quarterly basis for a minimum of 10% of all surgical pathology cases, fine needle aspirates, cytopathology cases and gynecologic cases.\nThis 10% review shall be performed by a pathologist certified in anatomic pathology. Reviews shall meet these review requirements:\nUnder no circumstances shall a resident physician act as a second reviewer for a staff pathologist.\nUnder no circumstances shall a staff pathologist review a resident physician s diagnosis as this does not constitute a second review.\nIndividuals performing a second review in GYN cytology shall have achieved a current successful GYN cytology competency assessment.\nThe review process shall be random, shall include all types of specimens and shall include a review of the entire case.\nAt least 10% of the cytotechnologist s gynecologic cases that have been interpreted as negative are routinely rescreened and are diagnosed and documented as being negative by a qualified pathologist.\nCases subjected for rescreening shall include some cases from high-risk patients, as well as random negative cases, based upon criteria established by the Chief or Director of Pathology and Laboratory Medical Services.\nAbility to instantly generate reports like cost Management Report, turn-around-time report, Utilization Report and any other quality management report requested by the site.\n\nPURCHASE CARD TRANSACTIONS\nContractor shall follow the Purchase Card Transactions procedures as directed in Section D, Attachment 7 for any tests ordered that were not originally on the contract.\n\nCUSTOMER SERVICE\nContractor shall provide customer service including IT support that is accessible by toll-free telephone service 24 hours per day, 7 days per week to assist Government staff for tracking and resolving related issues/problems that may arise in the performance under this agreement.\nUpon award, the Contractor shall provide the name(s) and telephone number(s) of contractor employees who will address customer services within 24 hours throughout the agreement.\nEnvironment of Care:\nAll significant problems identified shall be reported verbally to the COR within 24 hours. A written corrective plan of action shall be submitted to the COR within five (5) working days. VA timeframes and priorities for completion of action plan items shall be mutually agreed upon by the Contractor and the VA Safety Officer. The Contractor shall successfully pass the participating Facility Safety and Infection Control inspections prior to the provision of patient care.\nVA strives to ensure that the patients experience at each of the medical centers provides for convenience of obtaining all possible tests in one visit\nLeadership\nVA Primary Care services and operational activities provided at the participating Facility shall be designed and planned by leadership staff and shall reflect a uniform level of primary care as provided to veterans. The Contractor under the supervision of the PALMS Pathologists shall effectively manage and direct daily operations, information and support systems, and conserve physical and financial assets while meeting the mission of the VHA. PALMS Pathologists shall provide leadership oversight for improvement of clinical and administrative outcomes. The provision of contracted services shall be described in writing the nature and scope of services provided through contractual agreement. Leaders monitor contracted services by establishing expectations for the performance of the contracted services. Leaders take steps to improve contracted services that do not meet expectations.\nPersonnel Security\nAll Laboratory Directors who manage contractor personnel with direct access to the specimens and data received from and transmitted to the VA are required to complete a background investigation and receive a favorable adjudication from the Office of Security and Law Enforcement. Anyone with administrative or programmer access to a Federal computer system shall have a background investigation commensurate with the level of access granted to the VA computer system as determined by the Information Security Officer in concert with Human Resources Management Staff. These staff shall be operating within the borders of the U.S.A. and its territories.\nContinuing Education\nThe contractor shall provide ongoing continuing education material for Professional Acknowledgement for Continuing Education (PACE), Continuing Medical Education (CME) and Continuing Education (CE).\n\nDATA MANAGEMENT & CONNECTIVITY REQUIREMENTS\nData Management System\nContractor shall provide to the Government all necessary laboratory test parameters (parameters are required for each test contained in a panel) to insure accurate test result transmission between the Government and the Contractor s database. They shall provide all the IT support required for transition between reference labs, namely building existing and new test codes, test description, interface, troubleshooting and maintenance through the life of the contract. Required test parameters include:\nOrdering code\nLOINC code\nCPT code\nInterface code\nTest cost\nReference ranges\nUnits of measurement\nTest result interpretation or interpretive remarks, if appropriate\nTesting site (if not performed at the vendor s main laboratory facility\nTest methodology\nSpecimen types\nSpecimen collection and handling requirements\nIndication whether test is a panel/profile test, list of tests included\nThe parameters for all tests in the Contractor s database shall be kept current and be available to the Government sites throughout the performance period of the contract. Updates to the test parameter information must be provided to Government sites no less than 2 weeks prior to the implementation of any changes. The Contractor shall provide telephone access to a Contractor s technical representative to respond to any question(s) regarding the laboratory test parameter information.\nContractor shall be approved to be interfaced with ORACLE EHRM and be built at the enterprise level at the time of award.\nThe Contractor shall provide a data management system that meets the following requirements:\nTest ordering shall be accomplished through a menu that is intuitive, has minimal options, and uses a mouse or touch screen. Upon selection of the test, the computer shall alert (flag) the user to the type of specimen required and the storage conditions. It must also alert the user to the location of the laboratory that will be performing the test.\nTest definition, test information, and test requirements must be complete, available and easily accessible.\nShipping manifest shall be generated that identifies the specimens sent to the commercial reference laboratory, transportation conditions, and testing ordered.\nThe status and the results of testing shall be available within published timeframes and easily retrievable by the use of varying options. At a minimum the options must include:\nSort by patient name\nsort by date; sort by test\nsort by incomplete test.\nIncomplete tests must have an indication of the pending time until completion. Alert messages, or other notification, must be generated when testing is delayed beyond published timeframes.\nReports of test results must be immediately available upon verification of the test result. Contractor s computer located at the Government site must be able to print test results upon request and reprint retrospective test results.\nEquipment Security\nAny equipment provided by the Contractor to VA which contains a storage device such that when the device is powered down, VA sensitive data remains on it shall be sanitized prior to removal from the VA premises, shall become the property of the Federal Government and remain on Federal property or shall be destroyed in accordance with Department of Veterans Affairs regulations at the time of removal (device decommissioning). Data required by the HIPAA to remain on equipment located on Contractor's property shall be safeguarded in accordance with HIPAA and this information shall be destroyed in accordance with VA requirements when no longer required by HIPAA to be held by the vendor.\nVA Connectivity Requirements\nThe Contractor shall provide each participating facility the capacity to order lab testing and receive results through a secure web-based portal. The Contractor shall show that this portal meets VA requirements for encryption of sensitive patient information. The requirements that VA utilizes for these types of transmission shall be the Federal Information Processing Standard (FIPS) Publication 140-2. The Contractor shall be responsible for transmission of orders, confirmation of orders, test results, and the preventive maintenance of the system. Contractor shall be available to train the Facility s staff on the use of the system at each facility. An alternate method of sending orders and receiving results shall be in place in the event of system down time. A shipping manifest shall be generated that identifies the specimens sent to the reference laboratory, transportation conditions, and testing ordered.\nCERNER is a new VA computer system that will be utilized. The contractor shall ensure they have the ability to interface with CERNER and is operational and validation is complete with full menus complete at the time of contract award.\nThe Contractor shall have an electronic bi-directional interface system. The Contractor shall meet all Cyber Security requirements to establish an interconnection with the VA for transfer of test ordering details and laboratory test results directly from and into the VA computer system via the appropriate LEDI protocol. The interface shall be designed with a single data interface for the Facility which all sites shall utilize. The interface shall allow the generation of manifests to identify the specimens to be sent to the reference lab. Upon receipt of test results, the VA staff shall be able to review/validate test results before release. The Contractor shall be responsible for the purchase of any licenses for middleware products (e.g., Data Innovations) and hardware for any middleware or interface structure.\nIf the Contractor does not have a bi-directional electronic interface already in place, the Contractor shall have the following implemented within three (3) months of the contract award date. Contractor shall assist staff in the updating of the test database by providing all information required to create new test files for the required tests (i.e., sample requirements, shipping temperatures, reference ranges, CPT codes). Interface portal shall be connected and approved, including any required hardware, such as dedicated printers for labels and results. Interface validation shall be completed on the tests that have been updated in the database.\nDue to the difficulties encountered with any major reference laboratory interfacing change or upgrade, Contractor shall temporarily provide a single knowledgeable point of contact for researching correct test information, point(s) of contact for developing, testing, and implementing a client/vendor interface, and then an ongoing point of contact for troubleshooting interface problems. Temporary service shall be in effect until interfacing change or upgrade has been completed.\nThe Contractor shall meet all Enterprise Cyber Security Infrastructure Project (ECSIP) requirements in order to establish an interconnection with the VA for transfer of laboratory test results directly into a VA computer system via the appropriate LEDI protocol. The ECSIP team shall have the ultimate decision on which connection type is appropriate.\nThe Contractor shall provide the following interfacing requirements: Laboratory Information Systems LIS physical connection and translation (drivers) and any required (additional) interface connection license(s) and the Interface shall transmit test results to the host computer via automatic upload. The interface connection shall be tested and verified before putting into use.\nThe reference laboratory shall meet VA information security and Health Insurance Portability and Accountability Account of 1996 (HIPAA) requirements and shall be able to interface with the current or any new interface partner of the Laboratory Information System. The Contractor shall have all users with VA access complete the VHA privacy training prior to starting services.\nCERNER is a new Computerized Electronic Health Record that VA is in the process of transiting to. The Contractor shall ensure they have the capability and are able to interface with this system when it is implemented in addition to VISTA/CPRS that is currently in place.\nPerformance Improvement\nThe Contractor shall comply with the participating Facility Performance Improvement (PI) program as applicable to Pathology and Laboratory Medicine Service (PALMS). PALMS shall monitor the vendor s Test Assay Turn Around Times (TATs) on a quarterly basis. Vendor shall provide a quarterly TAT report for all patient testing requests sent for analysis. Quality Assurance Technologists shall provide a quarterly report to participating facility management teams for review. Contractor PI activities may be directed by the VA facility, VISN or VHA, as well as accreditation or licensing bodies. The Contractor shall abstract, compile and report PI data as requested by the VA. VA Data collection methodology, report format, and reporting deadlines shall be defined by the participating facility. Examples of required PI activities include the VHA Performance Measures/Clinical Practice Guidelines program, and the Joint Commission ORYX or Core Measurement program. It is noted that PI activities are dynamic and subject to change, as driven by current priorities and resources. In all cases, the Contractor shall continually assess for, and act upon, clinical and administrative improvement opportunities. High priority shall be given by the Contractor to the prevention of risk for the patient. The Contractor shall implement process-related internal controls to prevent risk to the veteran. VA monitoring for continuous compliance with Joint Commission standards shall be directed by VA staff and communicated to the Contractor through the COR. VA aggregate and/or practitioner-specific data collected by the VA shall be provided to the Contractor in accordance with established reporting schedules. VA measures related to contract compliance shall be identified by the COR\nInformation and Records Management\nThe participating Facility Information Management plan shall be followed by the Contractor. Documentation and record keeping shall be in accordance with the Facility policies and procedures. Strict adherence to all documentation related to the performance of invasive procedures shall be maintained. Identified medical record delinquency data shall be forwarded to the Contractor by the participating facility\nAutomated Data Processing (ADP) Security/HIPPA and Excluded Individuals\nThe VA shall provide access to the Veterans Health Information and Technology Architecture (VISTA) for Contractor employees. All Contractor employees accessing the VISTA system shall be required to sign and abide by all VAAAHS security policies and applicable VA confidentiality statutes, 38 U.S.C. Â§5701, 38 U.S.C. 7332, and the Privacy Act, 5 U.S.C. Â§552a. Background security investigations shall be completed before access to VISTA may be granted\nHealth and Human Service Office of Inspector General (HHS/OIG): To Ensure that the individuals providing services under the contract have not engaged in fraud or abuse regarding Sections 1128 and 1128A of the Social Security Act regarding federal health care programs, the Contractor is required to check the Health and Human Service Office of Inspector General List of excluded individuals/entities on the OIG Website (www.hhs.gov/oig) for each person providing services under this contract. Further, the Contractor is required to certify in its proposal that all persons listed in the Contractor s proposal have been compared against the OIG list and are not listed. During the performance of this contract the Contractor is prohibited from using any individual or business list on the List of Excluded Individuals/Entities\nTelecommunication Interface Requirements\nIn order for contract performance to begin within the shortest time possible after contract award, Contractor must already possess a current VA nationally approved Business Partner Gateway (BPG) Interconnection Security Agreement (ISA) and Memorandum of Understanding (MOU) and have an integrated system approach to facilitate and streamline all aspects of specimen ordering, testing, and reporting. As such, the Contractor shall develop and program an interface connection to electronically transmit orders, specimen status, and test results between the Contractor s host computer system and the Government s host computer system (VistA). (NOTE: A subcontractor may be utilized to outsource the connectivity solution.)\nThe VistA host computer system supports a Universal Interface (UI) and a Generic Instrument Manager (GIM). The GIM is a commercial hardware and software product that provides electronic connection between the Contractor s host computer and the Government s host computer. The configuration must provide the required security of the Government host computer system. The actual electronic connection between the GIM and the Contractor s host system is of the Contractor s choosing. The initial and continual expense of the electronic message connectivity and maintenance shall be borne by the Contractor throughout the performance of the contract.\nContractor shall provide, install, and if necessary, remove, all required telecommunication equipment, hardware, software, and related consumable supplies to support the transmission of electronic data to all sites referred to herein. This may include, but is not limited to:\nGeneric Instrument Manager (GIM) for the interface connection\nShipping list printers\nBar-code printers\nBack-up result printers connected directly to Contractor s computer system\nAny required communication lines\nSoftware to receive and send orders, display status of and/or test results\nConsumable supplies to maintain the operation of the equipment listed above, e.g., toner, etc.\nContractor shall be responsible for all annual recurring costs associated with support and maintenance of the Generic Instrument Manager (GIM) system including all GIM equipment, software, and instrument connections. The Generic Instrument Manager will be located in a government secured area. The Contractor shall coordinate with the respective Government Information Technology Department to access the GIM.\nThe Contractor shall conduct preventive maintenance and repair of Contractor furnished hardware, software, and associated communication lines. In addition, throughout the performance period of the contract, the Contractor shall repair or replace any malfunctioning hardware or software.\nAll electronic messaging between the two (Contractor and Government) host computer systems using the GIM shall utilize VistA Health Level Seven (HL7) V1.6 technical specifications. Health Level 7 (HL7) is a registered trademark of Health Level Seven, Inc, a Standards Developing Organization accredited by the American National Standards Institute to author consensus-based standards. Information regarding HL7 transmission protocols may be accessed through the Health Level Seven, Inc website, www.HL7.org.\nVistA Laboratory Electronic Data Interchange (LEDI): identifies Government-specific content and encoding tables to be used with HL7 message protocol conventions. The LEDI specification follows very closely the HL7 V2.3.1 standard. LEDI identifies encoding tables and HL7 message protocol conventions.\nLEDI also identifies to the commercial reference laboratory contractor shipping lists containing required specimen demographics and requested tests to be performed. This list will be provided in printed format during the implementation period. This information is also available in electronic HL7 format if required.\n(LEDI) software will provide a HL7 acknowledgement for the receipt of tests results from the contractor. In the event that electronic communication is disrupted, the contractor shall provide hard copy of specimen results upon demand. The hard copy must contain Government s assigned specimen identification where specimen identification is defined as a unique Government-assigned number that is associated with each specimen. This specimen identification number will appear on the test order form, on the specimen label and on the shipping manifest.\nThe Contractor shall provide the Government with specimen status in response to electronic and verbal query. Upon test completion, a formatted HL7 message containing specimen test results with Government s assigned specimen identification shall be returned to the requesting medical center.\nContractor shall address within two hours of initial inquiry, interface connection questions where information is required to update, maintain, and support the services of the host-to-host linkage between the Government and the Contractor.\nContractor shall provide in-service training required for the routine loading and care of printers and other hardware located on-site. The training will ensure that Government staff is capable of performing routine servicing of hardware.\n\nPOLICIES, REGULATIONS, AND COMPLIANCE STANDARDS\nPOLICIES AND REGULATIONS\nPolicy/Handbooks:\nVHA Handbook 1100.17: National Practitioner Data Bank Reports - https://www.va.gov/vhapublications/ViewPublication.asp?pub_ID=2135\nVHA Handbook 1100.19 Credentialing and Privileging - https://www.va.gov/vhapublications/ViewPublication.asp?pub_ID=2910\nVHA Handbook 1907.01 Health Information Management and Health Records: https://www.va.gov/vhapublications/ViewPublication.asp?pub_ID=3088\nPrivacy Act of 1974 (5 U.S.C. 552a) as amended: http://www.justice.gov/oip/foia_updates/Vol_XVII_4/page2.htm\nVHA Handbook 1106.01: Pathology and Laboratory Medicine Service (P&LMS) Procedures: https://www.va.gov/vhapublications/ViewPublication.asp?pub_ID=3169\nConformance Standards\nContractor shall maintain full compliance with applicable Federal and State regulations. All services provided under this contract shall be performed in conformance with the National Fire Protection Agency (NFPA) 99- Health Care Facility Code, Occupational Safety and Health Administration (OSHA), HIPAA, and other applicable national, state, and local regulatory agencies. Contractor shall maintain Clinical Laboratory Improvement Act (CLIA) certificate of accreditation, and The Joint Commission (JC) and the College of American Pathology (CAP, if required) accreditations. A copy of the CLIA certificate shall be provided to the participating Facility when requested\nContractor s Laboratory Director shall be a licensed American Board of Pathology certified pathologist. The Contractor shall make sure employees have current and valid professional certifications before starting work under this contract. All contractor personnel shall meet the performance characteristics for accuracy and precision as defined by the 1988 Clinical Laboratory Improvement Act (CLIA) and the Clinical and Laboratory Standards Institute (CLSI) and maintain required licenses. The Contractor shall maintain current licenses and certificates and provide copies of such to VA upon reasonable written request\nJoint Commission Compliance Standards\nAll applicable VA and VHA policies, procedures and directives shall be followed by the Contractor. The Contractor shall continuously meet or exceed all Joint Commission Hospital standards and provide oversight of care, treatment and services provided through contractual agreement standard LD.04.03.09. The patient population treated within the covered areas consists of veterans with varying physical, psychiatric, and psychological needs. Their conditions are in many cases, directly related to the individual s service to this country. Contract personnel shall provide compassionate care with respect for the special needs of the veteran population served. Care delivered shall reflect the VA Medical Centers mission, vision, and values:\nMISSION: Honor America s veterans by providing exceptional health care that improves their health and well-being.\nVISION: VHA shall continue to be the benchmark of excellence and value in health care and benefits by providing exemplary services that are both patients centered and evidenced based. This care shall be delivered by engaged, collaborative teams in an integrated environment that supports learning, discovery, and continuous improvement. It shall emphasize prevention and population health and contribute to the nation s well-being through education, research, and service in National emergencies.\nVALUES: VHA s five core values are Integrity, Commitment, Advocacy, Respect, and Excellence. They define our culture and how we care for our Veterans. They affect outcomes in our daily in\nSPECIAL CONTRACT REQUIREMENTS\nAWARD SPECIFIC INFORMATION\nModifications\nAll modifications shall be given at minimum 60 days for any change takes place. Modifications shall not be effective until executed.\nModifications that change the terms and conditions of the contract shall be bi-lateral.\nModifications that are administrative in nature may be completed unilaterally by the Government to update attachments, points of contacts, etc.\nPricing\nThis is a Firm Fixed Price (FFP) agreement with estimated quantities.\nPricing shall not change from the awarded pricing.\nVariable Priced Tests shall not be included. They will either need to be provided a FFP or not orderable through this agreement.\nPricing shall be determined and established at the time of award for ordering periods. Pricing shall not change.\nTests and Reflex Tests\nThe VA has estimated the quantity of tests that will be needed for the entirety of the agreement, including all ordering periods. Quantities may increase or decrease based on the Government s needs. Quantities are not guaranteed.\nAll tests and reflex tests shall be listed in the award with established test codes and pricing.\nOnly the tests and test codes listed in the award are authorized.\nNew Tests:\nmay be added to the award through a bi-lateral modification.\nshall not be utilized until a bilateral modification is executed.\npricing shall not change for any test replaced due to a test code/description change.\nTests Not Listed in the Award\nTests not listed in this award with the assigned test code/description are not authorized.\nAny test not listed or authorized shall follow a separate process unrelated to this agreement or through VA Community Care.\nContractor shall not process any test not listed in the award nor request payment for tests not listed through this agreement. Contractor risks non-payment of any test not authorized.\nEstablished Process for Non-Listed Test Codes/Descriptions (Non-Contracted):\nContractor shall set up a Non-Contracted Account Number\nAll Non-Contracted Tests shall not be processed without proper authorization prior to the test being processed.\n\nEMPLOYMENT AND LIABILITY\nThis is a non-personnel services contract. The Contractor shall be responsible for protecting the personnel furnishing services under this contract. To carry out this responsibility, the Contractor shall provide the following for these personnel, which includes worker s compensation, professional liability insurance, health examinations, income tax withholding and social security payments. The parties agree that Contractor personnel without formal appointments shall not be considered VA employees for any purpose and shall be considered employees of the Contractor\n\nINFECTION CONTROL\nContracted patient care activities shall be integrated into the participating Facility Infection Control program, and contract staff shall adhere to the Facility Infection Control policies and procedures. The Facility Infection Control Plan shall identify for the Contractor how risks shall be identified, methods to be used to reduce risk, identification and reporting of community-acquired and nosocomial infections, and data collection and reporting requirements. Reports of surveillance, control, prevention, and monitoring activities performed by the part Facility shall be provided, on a routine basis, to the Contractor.\n\nPATIENT SAFETY\nPatient safety shall be a primary focus of the Contractor including compliance with all applicable patient safety goals. The participating Facility shall inform the Contractor of all applicable Sentinel Events or other Patient Safety Alerts received by the Facility. For every applicable alert, the Contractor shall take the necessary steps to redesign processes to prevent occurrence and provide written feedback to the Contracting Officer Representative (COR) describing prevention actions taken. All events related to patient injury, medication errors, and other breeches of patient safety shall be documented utilizing the Contractor s format and reported to the COR utilizing the part Facility Incident Report. The Facility shall provide the Contractor with the Sentinel Event definitions in the start-up phase. The Contractor shall verbally notify the Facility COR immediately when a Sentinel Event has occurred, which is to be followed by written notification within one (1) business day or sooner if requested by the medical center. The Facility shall determine when a Root Cause Analysis (RCA) is required of the Contractor. The Contractor shall conduct all Root Cause Analysis according to the Facility policy and within established time frames (45 days). Completed RCAs shall be provided to the Facility COR.\n\nPATIENT RIGHTS\nProtection of all patients rights is of highest priority. Patient privacy and confidentiality shall be maintained at all times. Computer access shall be granted on a need-to-know basis, and security of computerized information shall be maintained at all times. No patients shall be subject to any research activity without his fully informed consent, subject to study approval by the Investigational Research Board (IRB). The Contractor shall abide by the participating Facility Code of Ethics, which addresses marketing, admission/transfer/referral/discharge processes, and billing issues. The Contractor and the patient care service provided shall be included in the participating Facility data collection activities related to patient and family complaints and satisfaction issues. Care provided shall respect and integrate the patient s beliefs, values, and cultural influences\n\nGOVERNMENT RESPONSIBILITIES\nCONTRACT PERFORMANCE MONITORING\nContractor's employee(s) shall report to the Laboratory Central Processing area, upon arrival at the VA for specimen pickup.\nMonitoring of contractor s performance shall be demonstrated through clinical and administrative record reviews. COR will be responsible for verifying contract compliance. Contracting Officer's Representative(s) (COR) will designate appropriate VA personnel to monitor services through one or a combination of the following mechanisms:\nDepartments being served will monitor Contractor performance to ensure that services called for in the contract have been received by VA in a timely manner. Any incidents of Contractor noncompliance as evidenced by the monitoring procedures will be forwarded immediately to the Contracting Officer.\nDocumentation of services performed will be reviewed prior to certifying payment. The COR will perform periodic spot checks and document with the using service to ensure records monitoring. VA will pay only for services actually provided, and in strict accordance with the Price/Cost Schedule. Contract monitoring and recordkeeping procedures will be sufficient to ensure proper payment and allow audit verification that services were provided.\nDepartments being served, through the COR(s), will provide a written statement annually to the Contracting Officer to include a summary of Contractor actions and a statement that all requirements of the contract have been fulfilled as agreed. This summary evaluation will be submitted 45 days prior to expiration of contract (and/or prior to ordering periods, if applicable).\n\nQUALITY ASSURANCE MONITORING\nContractor shall maintain a Quality Assurance Program related to Reference Laboratory services covered under this contract.\nContractor shall also participate in a joint quality assurance surveillance program (QASP) with the Government facilities. This program must minimally address the quality aspects representative to the testing process, i.e., pre-analytical, analytical, and post-analytical variables and include a description of monitoring and evaluation activities. There must be a mutually agreed upon procedure for responding to issues, problems and/or concerns identified by the Government with details as to whom and in what timeframe the matters will be reconciled. The issues that may need to be addressed may be general in nature or specific to an incident or event. The contractor will meet or communicate with the facility/VISN staff for process review and improvement of contract performance on an as needed basis.\nCopies of licensure/certifications are also required to be submitted upon request by the VA.\n\nPERFORMANCE STANDARDS\nLicensing, Accreditation, & Certification\nPerformance Requirement: Contractor shall maintain and provide CLIA Certification, CAP Accreditation, or equivalent; along with applicable OSHA, Federal, and State Laws for all laboratories, including any subcontractors.\nStandard: Proper certifications shall be kept up to date for the entire performance of this agreement. This includes all ordering periods.\nAcceptable Quality Level (AQL): 100% Meets Standard, no deviations are authorized.\nSurveillance Method: Periodic Sampling\nFrequency: Contractor shall provide all requested Licenses, Accreditations, and Certifications upon request of the Government at any time for all laboratories, to include all subcontractors.\nTechnical Quality\nPerformance Requirement: Produce high-quality, consistent access to reports, test code changes, errors in technical transmission issues.\nStandard: Meets quality requirements.\nAcceptable Quality Level (AQL): 95% Meets Standard\nSurveillance Method: Quarterly Review\nFrequency: COR to review issues with interfacing and notifications of test code changes, issues with test code results.\nTimeliness\nPerformance Requirement: Processes specimens and report test results within the stated turn-around-times.\nStandard: Timely courier pick-ups, specimen processing and reporting of all test results.\nAcceptable Quality Level (AQL): 90% Meets Standard\nSurveillance Method: Periodic Sampling\nFrequency: COR will review monthly reports\nTest Accuracy\nPerformance Requirement: Contractor shall provide accurate testing in accordance with the tests, test codes, test descriptions, specimen processing, and test results.\nStandard: Number of modified test results, not due to incorrect requisition information from referring lab.\nAcceptable Quality Level (AQL): < 0.02% of all patient results received.\nSurveillance Method: Monthly review\nFrequency: COR will review monthly reports.\nTransportation & Sample Integrity\nPerformance Requirement: Transportation and Quality standards outlined in the Performance Work Statement (PWS).\nStandard: Ensures integrity of samples during transportation to the performing laboratory.\nAcceptable Quality Level (AQL): < 3 lost specimens.\nSurveillance Method: Monthly review.\nFrequency: COR will review monthly reports and courier pick-up logs.\nAnatomic Pathology Random Review\nPerformance Requirement: Contractor shall perform retrospective case review.\nStandard: Staff pathologist to provide case reviews of 10% of all cases for pathology, surgical, cytology, hematopathology, mohs, and fine needle aspirate, etc.\nAcceptable Quality Level (AQL): 100% review and documenting of 10% of all cases.\nSurveillance Method: Monthly review\nFrequency: Contractor shall provide a monthly report to each facility COR providing all results of each review completed.\nBilling and Invoicing\nPerformance Requirement: Contractor shall ensure only tests listed in the award (test codes and descriptions) are billed through the award account. Contractor shall ensure that they meet all invoicing and billing requirements established in the award.\nStandard: Proper and correct invoicing.\nAcceptable Quality Level (AQL): 90%\nSurveillance Method: Monthly review.\nFrequency: Contractor shall submit on-time invoices with all required information monthly as established in this award.\nTracking Purchase Card Transactions\nPerformance Requirement: Contractor shall follow the procedures in Attachment 7\nStandard: Proper and correct tracking and notification of test results delivery and payment\nAcceptable Quality Level (AQL): 90%\nSurveillance Method: Monthly Review\nFrequency: Contractor shall submit monthly tracking spreadsheet as established in Attachment 7\n\nCONTRACT INCREASES UP TO 20% OF TOTAL CONTRACT VALUE\nDue to the unpredictable nature of the quantities and types of tests that will be required, any estimations will fall short of accurate. Therefore, the VA reserves the right to increase the total value of the contract up to no more than 20% of the total contract value by increasing the estimated quantities of tests required, and/or adding new tests to the list via a supplemental agreement in accordance with FAR 52.212-4. These modifications will occur on an estimated quarterly basis.\n\nINVOICING INSTRUCTIONS\nInvoice requirements and supporting documentation: Supporting documentation and invoice must be submitted no later than the 20th workday of the month for the month prior. Subsequent changes or corrections shall be submitted by separate invoice. In addition to information required for submission of a proper invoice in accordance with FAR 52.212-4 (g), all invoices must include:\nName and Address of Contractor\nInvoice Date and Invoice Number\nContract Number and Purchase/Task Order Number\nDate of Service\nInvoices shall not include any PII such as full name, social security number, or date of birth.Â\nAttached Excel spreadsheet Reference Lab Invoice Summary for each month with the total quantity for the corresponding invoice (this shall include every test in order as they appear in the award, even if the total is zero for that month).\nInvoices shall include the correct PO.\nInvoices shall be submitted electronically through Tungsten Services and be certified by VA COR for payment.\nAny test code names and/or quantities on a contract invoice that was paid for using a purchase card transaction will cause the invoice to be rejected in it s entirety.\nAny test code names and/or quantities that were not able to be provided due to specimen integrity failure will cause the invoice to be rejected in it s entirety.\nWhen invoicing, prior to the test name being updated via contract modification, the Contractor shall reference both the previous test code name and new test code name on the invoice.","html":"?.## PERFORMANCE WORK STATEMENT \nVETERANS INTEGRATED SERVICE NETWORK (VISN) 10\nBATTLE CREEK & WYOMING CBOC  REFERENCE LABORATORY TESTING SERVICES\nOverview \nThe Contractor shall enter into an Indefinite-Delivery Indefinite Quantity Contract (IDIQ) with the Battle Creek VAMC and Wyoming CBOC in Michigan to provide reference laboratory testing for the patients enrolled in the participating facilities.  Contractor shall provide all necessary supplies to provide reference laboratory testing services for the participating facilities below and all support facilities of the BCVAMC.  The IDIQ term shall be five (5) years.  This is a firm-fixed price IDIQ. The estimated quantities are for each test per year.\nBackground\nDepartment of Veterans Affairs, Veterans Health Administration (VHA), VISN 10, Battle Creek VAMC and Wyoming CBOC, requires the services of a contractor for reference laboratory testing services. The contractor shall provide reference laboratory testing for the patients enrolled in the participating facilities. Contractor shall provide all necessary supplies to provide reference laboratory testing services for both the participating facilities below and all support facilities.  \nReference Laboratory Services include at minimum specimen preparation and storage; transportation of clinical laboratory specimens; microbiology cultures and stocks; performance of analytical testing; reporting of analytical test results; consultative services; and reports as required by this document.\nPlaces of Performance \n\nBattle Creek VA Medical Center\n5500 Armstrong Road \nBattle Creek, MI 49037 \nUSA\n\nAND \n\nWyoming VA CBOC\n5838 Metro Way SW\nWyoming, MI 49519\nUSA\n\nSUPPORTING FACILITIES\nContractor shall ensure that supplies are provided as required by the Veterans Affairs Medical Center (VAMC).\nA VA courier will collect specimens from support facilities and those specimens will be collected by the contractor courier from their assigned participating facility on the dates and times listed in Section 5 below.\nGovernment reserves the right to add or remove supporting facilities as necessary.\n\nCONTRACTOR RESPONSIBILITIES\nOVERVIEW\nThe Contractor shall provide at minimum:\nAll necessary supplies for specialized specimen collection, testing, transport, and packaging, shipping kits \nSupplies shall be provided as the medical centers require additional supplies to support patient testing needs. (Government will provide Serum 2 supplies)\nCourier (not shipping) and flight services for the transportation of the specimens \nFlights to be made out of an airport that provides the best efficiency in getting the specimens to the contractor while maintaining specimen integrity. Contractor is responsible for specimen integrity once specimen leaves the VA facility.\nCourier service for pick-up of patient samples from facility s laboratory, shall be provided Monday   Saturday and pick-up times required by the site are identified below:\nBattle Creek VAMC   1 pickup Mon-Sat between 6:00PM and 7:00PM\nWyoming CBOC VAMC   1 pickup Mon-Sat between 6:00PM and 7:00PM\nDry ice (if required)\nChain of custody forms (if required)\nSpecimen transport request forms\nReference laboratory testing and reporting with current reference ranges. \nSecured web-based portal system, Intranet Laboratory Electronic Data Interchange (LEDI) system, and printer equipment including compatible ORACLE EHRM equipment.\nContractor must have interchange with the VA EHR computer system which will be installed during this contract at the time of award.\nContractor shall have a single national coding system. \nContractor shall utilize one test code per test nationally.\nContractor shall utilize approved Patient Identifiers \nCustomer telephone service 24/7 365 days a year\nContractor shall have an electronic test menu submission system as the preferred test submission avenue with limited specialty tests to be submitted on paper test submission forms.\nShipping manifest\nMonthly report to the VAMC to include, at a minimum, through an appropriate electronic format: (no PII/PHI can be included)\nTests ordered.\nNumber of unsatisfactory specimens\nNumber of tests performed in current month; and\nCalendar year-to-date with Current Procedural Terminology (CPT) code and cost. Reports to include all testing ordered for the calendar year.  \nThis report shall include pricing per account number for each participating site. \nProvide and maintain a user-friendly public website which allows easy reference for researching test information (test number/CPT coding, patient preparation, test utility, result interpretive guidelines. For tests not listed on public website Contractor shall provide access to their database for client research test information; and\nRoutine test results to the participating ordering facility within twenty-four (24) hours following test completion, except when specimens are picked up the day before a weekend or holiday (in which case the results shall be provided the following business day). The Contractor shall notify the facility within two (2) hours of any critical values or results.\nContractor s billing and utilization reports shall run from the first day of each month through the last day of each month.  For Example: January 1   January 31, February 1   28 or 29(if leap year), and June 1   June 30.\nQUALIFICATIONS\nLicensing and Accreditation\nOnly fully licensed/accredited laboratories actively engaged in providing the specific services and laboratory testing outlined in this solicitation shall be considered.  The Contractor/Subcontractor shall have all licenses, permits, accreditation and certificates required by law and be provided to the CO/COR at the time of award.  The reference laboratory shall be licensed/accredited by the College of American Pathologists (CAP) or The Joint Commission (TJC), or any other licensing and/or Accreditation in order to perform the required testing listed in this PWS.  In addition, the laboratory must be certified as meeting the requirements of the Department of Health and Human Services Clinical Laboratory Improvement Act of 1988 (CLIA).\nThe Contractor shall provide a copy of all relevant permits/licenses and certifications inclusive of all sanctions current or pending throughout the United States of America prior to contract award.  In addition, the Contractor shall be responsible for providing written guarantee or evidence that all Subcontractors have appropriate licensure and accreditation to perform tests that the primary Contractor cannot perform prior to contract award and as requested by the Contracting Officer (CO).  All proposed Subcontractor changes during the contract performance period must have prior approval by the CO. Changes to the requirements shall be addressed by bilateral modification.\nContractor Personnel assigned by the Contractor to perform the services covered by this contract shall be eligible to provide the services of this contract and licensed in a State, Territory, or Commonwealth of the United States or the District of Columbia.  All licenses held by Contractor personnel working on this contract shall be full and unrestricted licenses.  Contractor Personnel assigned by the Contractor to work under this contract shall be licensed by the governing or cognizant licensing board. \nContractor policies and procedures shall comply with Health Insurance Portability and Accountability Act (HIPPA)\nThe Contractor shall notify the Contracting Officer in writing of all malpractice investigation or licensure or certification suspension that concerns the Contractor or Contractor personnel, or any discovery of any disciplinary action taken against laboratory(ies) performing under the contract within 24 hours of notification of an investigation or suspension.\nContractor Personnel\nThe Contractor shall maintain current accreditation and notify the Contracting Officer of all lapses in state license, Clinical Laboratory Improvement Amendments (CLIA) certification, or clinical pathology certification.  The Contractor shall provide access via website or email upon request a copy of the renewed licenses/certificates before expiration.\nLaboratory Director shall be a licensed American Board of Pathology certified pathologist or appropriately certified bio-analyst.\nThe Contractor must have at least three years of experience providing laboratory services and must have at least one-year experience in transporting biomedical materials.\nCLIA certifications shall include approval for testing for the following disciplines/subdisciplines and effective dates of approval for each disciplines/subdisciplines\nHistocompatibility (010)\nBacteriology (110)\nMycobacteriology (115)\nMycology (120)\nParasitology\nVirology (140)\nSyphilis Serology (210)\nGeneral Immunology (220)\nRoutine Chemistry (310)\nUrinalysis (320)\nEndocrinology (330)\nToxicology (340)\nHematology (400)\nImmunohematology ABO Group & Rh type (510)\nImmunohematology Antibody Detection (transfusion) (520)\nImmunohematology Antibody Detection (non-transfusion) (530)\nImmunohematology Antibody Identification (540)\nImmunohematology Compatibility Testing (550)\nHistopathology (610)\nOral Pathology (620)\nSurgical Pathology\nMolecular Biology\nCytology (630)\nRadiobioassay (800)\nCytogenetics (900)\nAny changes to the CLIA certifications should be communicated to the facility within 24 hours. This also applies to the subcontractors.\nThe Contractor is required to provide all technical advisory/recalls/alerts, prior to or simultaneously with field alerts, should be forwarded to the designated individuals determined at contract award.\nThe Government reserves the right to refuse the use of a subcontractor who fails to comply with evidence of accreditation(s) or licensures(s)\nSPECIMEN PREPARATION\nContractor shall supply each Government facility with its commercial laboratory reference test manual to ensure that the collection and storage of specimens are in accordance with Contractor s requirements.\nContractor shall provide all materials necessary to collect and preserve specimens that are destined to the commercial reference laboratory for testing.  These materials include those items that are dictated by and in compliance with the collection requirements of the commercial reference laboratory. \nIf a medicolegal specimen is submitted, the Contractor shall provide its own special forms and special handling procedures to maintain a valid  chain-of-custody possession  and develop the formal documentation necessary for that purpose.  Contractor s testing personnel who performed the analysis may be required to provide Court testimony.  Contractor testimony shall be provided as required at no additional expense to the Government.  \nContractor shall be responsible for storing specimens in such a manner to ensure the integrity of the specimen.\nSPECIMEN TRANSPORATION\nContractor shall provide transportation of primarily biomedical materials that include patient specimens, cultures, and stocks, originating from Government facilities and destined to the contracted commercial reference laboratory.  \nThese specimens are classified as Hazard Materials Class 6, Division 6.2 and are defined in 49 CFR Part 173.134 as those materials that contain or could contain etiologic agents.  Transportation shall be done in such a manner that the safety and integrity of the biomedical material is maintained.\nTransportation/Courier Services for pick-up of patient samples from the Government facilities listed in this document shall be provided by the contractor.\nThe Government reserves the right to adjust the courier pick-up days and times as necessary, provided a two-week notice has been provided and acknowledged by the Contractor at no additional charge to the Government.\nThe Government reserves the right to add or remove courier pick-up locations provided a two-week notice has been provided and acknowledged by the Contractor at no additional charge to the Government.\nProcessing shall begin immediately upon receipt at the testing site and results provided within the laboratory established turnaround times.\nCourier services shall be available seven (7) days a week, including Federal holidays as required.  A list of Federal Holidays can be found in the following Link: Federal Holidays (opm.gov)\nContractor shall provide all necessary supplies for biomedical materials to be transported from the VA medical facility to the performing laboratory.  These supplies shall include at minimum:\nShipping and packaging containers.  Packing material must be capable of maintaining temperature requirements for specimens until they reach the Contractor s laboratory.\nRequired labels and packaging materials for shipping specimens via courier that are infectious, or etiologic agents, in accordance with appropriate requirements of 42 CFR Part 72, 49 CFR Parts 171 and 173, and the Dangerous Goods Regulations of the International Air Transport Association (IATA) consistent with current regulatory updates.  \nTest request forms, preprinted with the appropriate Shipping Section details and account information. \nTest request forms for specialized testing (i.e., cytogenetics, tissue, etc.).\nPrinter and printer supplies including paper, labels, and toner/ ink cartridges, in sufficient quantities to perform work under this contract.\n\nSPECIMEN TESTING\nContractor shall ensure test sample integrity is maintained at all times from the time they are picked up from the participating facility and delivered to the processing laboratory.\nContractor shall provide the full range of laboratory testing capabilities to execute all required test orders as annotated in this agreement.  \nAll the testing should be performed on the Contractors premises or within the Contractor s network labs (as official or qualified subcontractor). Under no circumstance should the contractor allow any patient information to cross the US borders. Contractor referral to the secondary laboratory or subcontractor should be kept to a minimum for control and uniformity purpose. Subcontractor should be held to the same quality standard as specified in the contract. \nContractor shall make available the following test information:\nRequisition form requirements \nAlphabetized test name list\nTest order code\nSpecimen collection and preservation requirements\nTest method employed (indicate if testing performed in duplicate) and interpretations\nTest reference intervals adjusted for age, sex, or race, when required\nTest specific sensitivity, specificity, and interferences, when required\nResult code\nTest critical values if any\nPolicy for critical value notification\nCPT coding\nTest turnaround times (minimum and maximum times indicated); where the turnaround time is defined as the time between receipt of specimen by the Contractor and receipt of results by a government facility.\nSchedule of test performance (specific days of week indicated)\nLocation of test performance by test name (i.e., name of primary laboratory, name of separate branch/division of primary lab, name, and address of secondary (sub-contracted) laboratory must be cited)\nContractor shall notify the Site Contracting Officer Representative (COR) for each participating facility of any test submitted to be processed that does not match this agreement prior to being tested so that the appropriate process can be followed to process the test.\nAll reference laboratory testing is preferred to be tested using test methods that are FDA approved.  \nAny non-FDA approved method being performed shall have a disclaimer and documented validation plan.  \nUpon request, the validation plan and validation results shall be made available to the COR or designee.\nContractor shall ensure the accurate and timely performance of laboratory testing services on all tests within this agreement.\n\nSPECIMEN RETENTION\nAll anatomic pathology materials (e.g., histology blocks, slides, or other diagnostic material) generated by the VA shall be returned within 7 days after final diagnosis is reported. \n\nTEST RESULTS & REPORTS\nTest Results:\nIf the Contractor is unable to perform the test due to issues with the specimen integrity, the Contractor shall inform the VA as soon as possible, via email to the designated COR, with a maximum time of 24-hours of receipt of the specimen.\nOnce testing is completed, the laboratory results shall be transmitted via secured web-based portal system or the LEDI system to each participating facility via VAMC VISTA/CERNER computer system and printer equipment provided by the Contractor that will be located at each participating facility.\nAlternate methods of reporting results in the event of electronic system failure may include:\nElectronic delivery of all reports is preferred.\nFaxed, please verify fax number prior to sending patient results as fax numbers are subject to change:\n269-966-5483 \nAll test results provided by the Contractor/subcontractor shall contain at minimum the following:\nTwo (2) full patient identifiers, one of which is patient s full name\nPhysician s name\nTesting facility name and address\nClinical Laboratory Improvement Amendments CLIA number (if requested)\nAccount number\nDate/time specimen was collected\nDate/time specimen was received\nDate/time test was reported\nContractor generated Laboratory Accession Number\nVA generated Laboratory Accession Number \nTest ordered\nTest result\nFlagged abnormal results\nReference ranges\nType of specimen\nAny additional comments related to test provided by submitting lab\nAny other information the laboratory has that may indicate a questionable validity of test results; and\nUnsatisfactory specimens shall be reported with regard to its unsuitability for testing.\nCorrected reports shall be issued in accordance with accreditation requirements.\nThe Contractor shall return representative slides, anatomic, hematologic, etc., for quality control review when requested.  Quality control slides shall represent duplicate copies of original slides prepared by the Contractor from permanent tissue blocks.  The Contractor shall provide quality control slides to the facility or clinics at the same time the Contractor submits the final reports.   The Contractor shall prepare additional blocks and slides, in quantities specified by the facility for review by pathologists.  For malignant cases, the Contractor shall call results to the submitting facility, and prepare paraffin blocks and slides for review by the Joint Pathology Center (JPC) or other Government Pathology Organization (GPO). For benign cases, the Contractor shall prepare slides for review by the facility.  Upon provision of sample slides by the facility, the Contractor shall provide interpretation of sample slides.  The sample shall include, at a minimum, breast biopsy, thyroid biopsy, mastectomy with nodes, colon resection, lymph node biopsy, and gynecology and non-gynecology cytology.\nThe Contractor shall store all blood and fluid specimens after all testing has been completed in the event repeat or add on testing for one (1) week at conditions that shall maintain sample viability.  Upon request, samples shall be returned to the collecting VA facility via courier at conditions that shall maintain sample viability, at no additional charge to the VA.  All anatomical pathology specimens (i.e., slides, blocks, etc.) shall be returned within two (2) weeks of test completion.\nReports:\nAll Reports shall run from the 1st day of each month through the last day of each month. For Example: January 1   January 31, February 1   28 or 29 (if leap year), and June 1   June 30.\nContractor shall prove consultative services that are consistent with the services offered to other contracted customers without compensation.  These services may include consultations by laboratory professionals or experienced physicians on test or methodology selection or test result interpretation.\nContractor shall provide access to online statistical analysis and metrics of the Government facilities  test utilization reports to assist in the monitoring of ordering trends and utilization patterns. The contractor shall make recommendations to the facilities on mechanisms to reduce their costs and provide recommendations for improvements in testing and results.\nTest utilization (number and cost)\nTrending of test utilization (number and cost)\nLine graph AND\nTotal number\nTest utilization by provider\nContractor shall provide a cumulative workload summary report of tests performed. The summary must include the facility account number, the test name, the test ordering code, monthly test volume, year-to-date test volume, unit test cost, monthly test expenditures and year-to date test expenditures, the VA and Test Lab generated accession numbers, and the name and address of the testing laboratory (contractor and subcontractor). \nA copy of the report shall be delivered electronically to the Contracting Officer and COR by the 10th of the month following the close of the reporting month.\nAll reports shall be submitted in electronic spreadsheet format and have the capability to sort by four (4) different methods:\nFacility account number\nTest names listed alphabetically\nTest names listed in order of year-to-date test frequency (highest to lowest)\nTest names listed in order of year-to-date total test cost (highest to lowest)\nAdditional Administration Requirements / Reports \nThe Contractor shall provide an updated copy of the Excel spreadsheet  Reference Lab Invoice Summary  to the Contracting Officer, COR by the 10th of the month following the close of the reporting month. The Contractor shall update the quantities of tests invoiced during the prior month in this spreadsheet. \nContractor shall provide a monthly listing of any tests listed in Section D, Attachment 2 entitled  Price-Cost Schedule - Battle Creek and Wyoming CBOC Reference Labs  that 1) are no longer performed by contractor or 2) the test name is updated. The Contractor shall highlight the rows RED in the Excel Spreadsheet  Declining Balances Monthly Test Tracker  for any test codes that are no longer performed by the Contractor or have updated test names and make a note in the  Notes  column. These tests will be either removed or updated via a supplemental agreement in accordance with 52.212-4. When invoicing, prior to the test name being updated via contract modification, the Contractor shall reference the previous test code name and new test code name on the invoice.  \nThe Contractor shall make all reasonable effort to notify the VA that a test ordered against the contract is not listed in Section D, Attachment 2, in order to avoid an unauthorized commitment. \nFor tests that are ordered that are not listed in Section D, Attachment 2, the Purchase Card Procedures in Section D, Attachment 7 entitled  Purchase Card Procedures for VA and Contractor  shall be utilized. These procedures include the requirement that the Contractor shall provide an updated Excel Spreadsheet,  Purchase Card Transactions,  that tracks the test name and/or test ordering code, quantity of each test performed, and proposed pricing.\n\nQUALITY REVIEW\nContractor shall provide the following:\nIn accordance with VHA Handbook 1106 a 10% retrospective quality management peer review shall be completed.  This review shall be completed by a second pathologist on at least a quarterly basis for a minimum of 10% of all surgical pathology cases, fine needle aspirates, cytopathology cases and gynecologic cases.\nThis 10% review shall be performed by a pathologist certified in anatomic pathology.  Reviews shall meet these review requirements:\nUnder no circumstances shall a resident physician act as a second reviewer for a staff pathologist.\nUnder no circumstances shall a staff pathologist review a resident physician s diagnosis as this does not constitute a second review.\nIndividuals performing a second review in GYN cytology shall have achieved a current successful GYN cytology competency assessment.\nThe review process shall be random, shall include all types of specimens and shall include a review of the entire case.\nAt least 10% of the cytotechnologist s gynecologic cases that have been interpreted as negative are routinely rescreened and are diagnosed and documented as being negative by a qualified pathologist.\nCases subjected for rescreening shall include some cases from high-risk patients, as well as random negative cases, based upon criteria established by the Chief or Director of Pathology and Laboratory Medical Services.\nAbility to instantly generate reports like cost Management Report, turn-around-time report, Utilization Report and any other quality management report requested by the site.\n\nPURCHASE CARD TRANSACTIONS\nContractor shall follow the Purchase Card Transactions procedures as directed in Section D, Attachment 7 for any tests ordered that were not originally on the contract. \n\nCUSTOMER SERVICE\nContractor shall provide customer service including IT support that is accessible by toll-free telephone service 24 hours per day, 7 days per week to assist Government staff for tracking and resolving related issues/problems that may arise in the performance under this agreement.\nUpon award, the Contractor shall provide the name(s) and telephone number(s) of contractor employees who will address customer services within 24 hours throughout the agreement.\nEnvironment of Care:\nAll significant problems identified shall be reported verbally to the COR within 24 hours. A written corrective plan of action shall be submitted to the COR within five (5) working days. VA timeframes and priorities for completion of action plan items shall be mutually agreed upon by the Contractor and the VA Safety Officer.  The Contractor shall successfully pass the participating Facility  Safety and Infection Control inspections prior to the provision of patient care.\nVA strives to ensure that the patients experience at each of the medical centers provides for convenience of obtaining all possible tests in one visit\nLeadership\nVA Primary Care services and operational activities provided at the participating Facility shall be designed and planned by leadership staff and shall reflect a uniform level of primary care as provided to veterans.  The Contractor under the supervision of the PALMS Pathologists shall effectively manage and direct daily operations, information and support systems, and conserve physical and financial assets while meeting the mission of the VHA. PALMS Pathologists shall provide leadership oversight for improvement of clinical and administrative outcomes. The provision of contracted services shall be described in writing the nature and scope of services provided through contractual agreement. Leaders monitor contracted services by establishing expectations for the performance of the contracted services. Leaders take steps to improve contracted services that do not meet expectations.\nPersonnel Security\nAll Laboratory Directors who manage contractor personnel with direct access to the specimens and data received from and transmitted to the VA are required to complete a background investigation and receive a favorable adjudication from the Office of Security and Law Enforcement. Anyone with administrative or programmer access to a Federal computer system shall have a background investigation commensurate with the level of access granted to the VA computer system as determined by the Information Security Officer in concert with Human Resources Management Staff. These staff shall be operating within the borders of the U.S.A. and its territories.\nContinuing Education\nThe contractor shall provide ongoing continuing education material for Professional Acknowledgement for Continuing Education (PACE), Continuing Medical Education (CME) and Continuing Education (CE). \n\nDATA MANAGEMENT & CONNECTIVITY REQUIREMENTS\nData Management System\nContractor shall provide to the Government all necessary laboratory test parameters (parameters are required for each test contained in a panel) to insure accurate test result transmission between the Government and the Contractor s database.  They shall provide all the IT support required for transition between reference labs, namely building existing and new test codes, test description, interface, troubleshooting and maintenance through the life of the contract. Required test parameters include:  \nOrdering code\nLOINC code\nCPT code\nInterface code\nTest cost\nReference ranges\nUnits of measurement\nTest result interpretation or interpretive remarks, if appropriate\nTesting site (if not performed at the vendor s main laboratory facility\nTest methodology\nSpecimen types\nSpecimen collection and handling requirements\nIndication whether test is a panel/profile test, list of tests included \nThe parameters for all tests in the Contractor s database shall be kept current and be available to the Government sites throughout the performance period of the contract.  Updates to the test parameter information must be provided to Government sites no less than 2 weeks prior to the implementation of any changes.  The Contractor shall provide telephone access to a Contractor s technical representative to respond to any question(s) regarding the laboratory test parameter information. \nContractor shall be approved to be interfaced with ORACLE EHRM and be built at the enterprise level at the time of award.\nThe Contractor shall provide a data management system that meets the following requirements:  \nTest ordering shall be accomplished through a menu that is intuitive, has minimal options, and uses a mouse or touch screen.  Upon selection of the test, the computer shall alert (flag) the user to the type of specimen required and the storage conditions.  It must also alert the user to the location of the laboratory that will be performing the test.\nTest definition, test information, and test requirements must be complete, available and easily accessible.\nShipping manifest shall be generated that identifies the specimens sent to the commercial reference laboratory, transportation conditions, and testing ordered.\nThe status and the results of testing shall be available within published timeframes and easily retrievable by the use of varying options.  At a minimum the options must include: \nSort by patient name \nsort by date; sort by test \nsort by incomplete test.  \nIncomplete tests must have an indication of the pending time until completion.  Alert messages, or other notification, must be generated when testing is delayed beyond published timeframes.   \nReports of test results must be immediately available upon verification of the test result.  Contractor s computer located at the Government site must be able to print test results upon request and reprint retrospective test results.\nEquipment Security\nAny equipment provided by the Contractor to VA which contains a storage device such that when the device is powered down, VA sensitive data remains on it shall be sanitized prior to removal from the VA premises, shall become the property of the Federal Government and remain on Federal property or shall be destroyed in accordance with Department of Veterans Affairs regulations at the time of removal (device decommissioning). Data required by the HIPAA to remain on equipment located on Contractor's property shall be safeguarded in accordance with HIPAA and this information shall be destroyed in accordance with VA requirements when no longer required by HIPAA to be held by the vendor.\nVA Connectivity Requirements\nThe Contractor shall provide each participating facility the capacity to order lab testing and receive results through a secure web-based portal.  The Contractor shall show that this portal meets VA requirements for encryption of sensitive patient information. The requirements that VA utilizes for these types of transmission shall be the Federal Information Processing Standard (FIPS) Publication 140-2. The Contractor shall be responsible for transmission of orders, confirmation of orders, test results, and the preventive maintenance of the system.  Contractor shall be available to train the Facility s staff on the use of the system at each facility. An alternate method of sending orders and receiving results shall be in place in the event of system down time.  A shipping manifest shall be generated that identifies the specimens sent to the reference laboratory, transportation conditions, and testing ordered.\nCERNER is a new VA computer system that will be utilized. The contractor shall ensure they have the ability to interface with CERNER and is operational and validation is complete with full menus complete at the time of contract award.\nThe Contractor shall have an electronic bi-directional interface system.  The Contractor shall meet all Cyber Security requirements to establish an interconnection with the VA for transfer of test ordering details and laboratory test results directly from and into the VA computer system via the appropriate LEDI protocol. The interface shall be designed with a single data interface for the Facility which all sites shall utilize.  The interface shall allow the generation of manifests to identify the specimens to be sent to the reference lab.  Upon receipt of test results, the VA staff shall be able to review/validate test results before release.  The Contractor shall be responsible for the purchase of any licenses for middleware products (e.g., Data Innovations) and hardware for any middleware or interface structure.\nIf the Contractor does not have a bi-directional electronic interface already in place, the Contractor shall have the following implemented within three (3) months of the contract award date. Contractor shall assist staff in the updating of the test database by providing all information required to create new test files for the required tests (i.e., sample requirements, shipping temperatures, reference ranges, CPT codes).  Interface portal shall be connected and approved, including any required hardware, such as dedicated printers for labels and results.  Interface validation shall be completed on the tests that have been updated in the database.\nDue to the difficulties encountered with any major reference laboratory interfacing change or upgrade, Contractor shall temporarily provide a single knowledgeable point of contact for researching correct test information, point(s) of contact for developing, testing, and implementing a client/vendor interface, and then an ongoing point of contact for troubleshooting interface problems. Temporary service shall be in effect until interfacing change or upgrade has been completed.\nThe Contractor shall meet all Enterprise Cyber Security Infrastructure Project (ECSIP) requirements in order to establish an interconnection with the VA for transfer of laboratory test results directly into a VA computer system via the appropriate LEDI protocol. The ECSIP team shall have the ultimate decision on which connection type is appropriate.\nThe Contractor shall provide the following interfacing requirements: Laboratory Information Systems LIS physical connection and translation (drivers) and any required (additional) interface connection license(s) and the Interface shall transmit test results to the host computer via automatic upload.  The interface connection shall be tested and verified before putting into use.\nThe reference laboratory shall meet VA information security and Health Insurance Portability and Accountability Account of 1996 (HIPAA) requirements and shall be able to interface with the current or any new interface partner of the Laboratory Information System. The Contractor shall have all users with VA access complete the VHA privacy training prior to starting services.\nCERNER is a new Computerized Electronic Health Record that VA is in the process of transiting to. The Contractor shall ensure they have the capability and are able to interface with this system when it is implemented in addition to VISTA/CPRS that is currently in place.\nPerformance Improvement\nThe Contractor shall comply with the participating Facility Performance Improvement (PI) program as applicable to Pathology and Laboratory Medicine Service (PALMS). PALMS shall monitor the vendor s Test Assay Turn Around Times (TATs) on a quarterly basis.  Vendor shall provide a quarterly TAT report for all patient testing requests sent for analysis. Quality Assurance Technologists shall provide a quarterly report to participating facility management teams for review.  Contractor PI activities may be directed by the VA facility, VISN or VHA, as well as accreditation or licensing bodies. The Contractor shall abstract, compile and report PI data as requested by the VA. VA Data collection methodology, report format, and reporting deadlines shall be defined by the participating facility. Examples of required PI activities include the VHA Performance Measures/Clinical Practice Guidelines program, and the Joint Commission ORYX or Core Measurement program. It is noted that PI activities are dynamic and subject to change, as driven by current priorities and resources. In all cases, the Contractor shall continually assess for, and act upon, clinical and administrative improvement opportunities. High priority shall be given by the Contractor to the prevention of risk for the patient. The Contractor shall implement process-related internal controls to prevent risk to the veteran. VA monitoring for continuous compliance with Joint Commission standards shall be directed by VA staff and communicated to the Contractor through the COR. VA aggregate and/or practitioner-specific data collected by the VA shall be provided to the Contractor in accordance with established reporting schedules. VA measures related to contract compliance shall be identified by the COR\nInformation and Records Management\nThe participating Facility  Information Management plan shall be followed by the Contractor. Documentation and record keeping shall be in accordance with the Facility  policies and procedures. Strict adherence to all documentation related to the performance of invasive procedures shall be maintained. Identified medical record delinquency data shall be forwarded to the Contractor by the participating facility\nAutomated Data Processing (ADP) Security/HIPPA and Excluded Individuals\nThe VA shall provide access to the Veterans Health Information and Technology Architecture (VISTA) for Contractor employees. All Contractor employees accessing the VISTA system shall be required to sign and abide by all VAAAHS security policies and applicable VA confidentiality statutes, 38 U.S.C. Â§5701, 38 U.S.C. 7332, and the Privacy Act, 5 U.S.C. Â§552a.  Background security investigations shall be completed before access to VISTA may be granted\nHealth and Human Service   Office of Inspector General (HHS/OIG):  To Ensure that the individuals providing services under the contract have not engaged in fraud or abuse regarding Sections 1128 and 1128A of the Social Security Act regarding federal health care programs, the Contractor is required to check the Health and Human Service   Office of Inspector General List of excluded individuals/entities on the OIG Website (www.hhs.gov/oig) for each person providing services under this contract.  Further, the Contractor is required to certify in its proposal that all persons listed in the Contractor s proposal have been compared against the OIG list and are not listed.  During the performance of this contract the Contractor is prohibited from using any individual or business list on the List of Excluded Individuals/Entities\nTelecommunication Interface Requirements\nIn order for contract performance to begin within the shortest time possible after contract award, Contractor must already possess a current VA nationally approved Business Partner Gateway (BPG) Interconnection Security Agreement (ISA) and Memorandum of Understanding (MOU) and have an integrated system approach to facilitate and streamline all aspects of specimen ordering, testing, and reporting.  As such, the Contractor shall develop and program an interface connection to electronically transmit orders, specimen status, and test results between the Contractor s host computer system and the Government s host computer system (VistA).  (NOTE:  A subcontractor may be utilized to outsource the connectivity solution.) \nThe VistA host computer system supports a Universal Interface (UI) and a Generic Instrument Manager (GIM).  The GIM is a commercial hardware and software product that provides electronic connection between the Contractor s host computer and the Government s host computer.  The configuration must provide the required security of the Government host computer system.  The actual electronic connection between the GIM and the Contractor s host system is of the Contractor s choosing. The initial and continual expense of the electronic message connectivity and maintenance shall be borne by the Contractor throughout the performance of the contract.\nContractor shall provide, install, and if necessary, remove, all required telecommunication equipment, hardware, software, and related consumable supplies to support the transmission of electronic data to all sites referred to herein.  This may include, but is not limited to:\nGeneric Instrument Manager (GIM) for the interface connection\nShipping list printers\nBar-code printers\nBack-up result printers connected directly to Contractor s computer system\nAny required communication lines\nSoftware to receive and send orders, display status of and/or test results\nConsumable supplies to maintain the operation of the equipment listed above, e.g., toner, etc.\nContractor shall be responsible for all annual recurring costs associated with support and maintenance of the Generic Instrument Manager (GIM) system including all GIM equipment, software, and instrument connections.  The Generic Instrument Manager will be located in a government secured area.  The Contractor shall coordinate with the respective Government Information Technology Department to access the GIM.\nThe Contractor shall conduct preventive maintenance and repair of Contractor furnished hardware, software, and associated communication lines.  In addition, throughout the performance period of the contract, the Contractor shall repair or replace any malfunctioning hardware or software. \nAll electronic messaging between the two (Contractor and Government) host computer systems using the GIM shall utilize VistA Health Level Seven (HL7) V1.6 technical specifications.  Health Level 7 (HL7) is a registered trademark of Health Level Seven, Inc, a Standards Developing Organization accredited by the American National Standards Institute to author consensus-based standards.  Information regarding HL7 transmission protocols may be accessed through the Health Level Seven, Inc website, www.HL7.org.\nVistA Laboratory Electronic Data Interchange (LEDI):  identifies Government-specific content and encoding tables to be used with HL7 message protocol conventions.  The LEDI specification follows very closely the HL7 V2.3.1 standard.  LEDI identifies encoding tables and HL7 message protocol conventions.  \nLEDI also identifies to the commercial reference laboratory contractor shipping lists containing required specimen demographics and requested tests to be performed.  This list will be provided in printed format during the implementation period.  This information is also available in electronic HL7 format if required.  \n(LEDI) software will provide a HL7 acknowledgement for the receipt of tests results from the contractor.   In the event that electronic communication is disrupted, the contractor shall provide hard copy of specimen results upon demand.  The hard copy must contain Government s assigned specimen identification where specimen identification is defined as a unique Government-assigned number that is associated with each specimen.  This specimen identification number will appear on the test order form, on the specimen label and on the shipping manifest.   \nThe Contractor shall provide the Government with specimen status in response to electronic and verbal query.  Upon test completion, a formatted HL7 message containing specimen test results with Government s assigned specimen identification shall be returned to the requesting medical center.\nContractor shall address within two hours of initial inquiry, interface connection questions where information is required to update, maintain, and support the services of the host-to-host linkage between the Government and the Contractor. \nContractor shall provide in-service training required for the routine loading and care of printers and other hardware located on-site.  The training will ensure that Government staff is capable of performing routine servicing of hardware.\n\nPOLICIES, REGULATIONS, AND COMPLIANCE STANDARDS\nPOLICIES AND REGULATIONS\nPolicy/Handbooks:\nVHA Handbook 1100.17: National Practitioner Data Bank Reports - https://www.va.gov/vhapublications/ViewPublication.asp?pub_ID=2135 \nVHA Handbook 1100.19 Credentialing and Privileging - https://www.va.gov/vhapublications/ViewPublication.asp?pub_ID=2910 \nVHA Handbook 1907.01 Health Information Management and Health Records: https://www.va.gov/vhapublications/ViewPublication.asp?pub_ID=3088 \nPrivacy Act of 1974 (5 U.S.C. 552a) as amended: http://www.justice.gov/oip/foia_updates/Vol_XVII_4/page2.htm \nVHA Handbook 1106.01:  Pathology and Laboratory Medicine Service (P&LMS) Procedures: https://www.va.gov/vhapublications/ViewPublication.asp?pub_ID=3169 \nConformance Standards\nContractor shall maintain full compliance with applicable Federal and State regulations.  All services provided under this contract shall be performed in conformance with the National Fire Protection Agency (NFPA) 99- Health Care Facility Code, Occupational Safety and Health Administration (OSHA), HIPAA, and other applicable national, state, and local regulatory agencies. Contractor shall maintain Clinical Laboratory Improvement Act (CLIA) certificate of accreditation, and The Joint Commission (JC) and the College of American Pathology (CAP, if required) accreditations. A copy of the CLIA certificate shall be provided to the participating Facility when requested\nContractor s Laboratory Director shall be a licensed American Board of Pathology certified pathologist.  The Contractor shall make sure employees have current and valid professional certifications before starting work under this contract.  All contractor personnel shall meet the performance characteristics for accuracy and precision as defined by the 1988 Clinical Laboratory Improvement Act (CLIA) and the Clinical and Laboratory Standards Institute (CLSI) and maintain required licenses.  The Contractor shall maintain current licenses and certificates and provide copies of such to VA upon reasonable written request\nJoint Commission Compliance Standards\nAll applicable VA and VHA policies, procedures and directives shall be followed by the Contractor. The Contractor shall continuously meet or exceed all Joint Commission Hospital standards and provide oversight of care, treatment and services provided through contractual agreement standard LD.04.03.09. The patient population treated within the covered areas consists of veterans with varying physical, psychiatric, and psychological needs. Their conditions are in many cases, directly related to the individual s service to this country. Contract personnel shall provide compassionate care with respect for the special needs of the veteran population served. Care delivered shall reflect the VA Medical Centers mission, vision, and values:\nMISSION: Honor America s veterans by providing exceptional health care that improves their health and well-being.\nVISION: VHA shall continue to be the benchmark of excellence and value in health care and benefits by providing exemplary services that are both patients centered and evidenced based. This care shall be delivered by engaged, collaborative teams in an integrated environment that supports learning, discovery, and continuous improvement. It shall emphasize prevention and population health and contribute to the nation s well-being through education, research, and service in National emergencies.\nVALUES: VHA s five core values are Integrity, Commitment, Advocacy, Respect, and Excellence.  They define our culture and how we care for our Veterans.  They affect outcomes in our daily in\nSPECIAL CONTRACT REQUIREMENTS\nAWARD SPECIFIC INFORMATION\nModifications\nAll modifications shall be given at minimum 60 days for any change takes place.  Modifications shall not be effective until executed.\nModifications that change the terms and conditions of the contract shall be bi-lateral.\nModifications that are administrative in nature may be completed unilaterally by the Government to update attachments, points of contacts, etc.\nPricing\nThis is a Firm Fixed Price (FFP) agreement with estimated quantities.\nPricing shall not change from the awarded pricing.\nVariable Priced Tests shall not be included.  They will either need to be provided a FFP or not orderable through this agreement.\nPricing shall be determined and established at the time of award for ordering periods.  Pricing shall not change.\nTests and Reflex Tests\nThe VA has estimated the quantity of tests that will be needed for the entirety of the agreement, including all ordering periods.  Quantities may increase or decrease based on the Government s needs.  Quantities are not guaranteed.\nAll tests and reflex tests shall be listed in the award with established test codes and pricing.\nOnly the tests and test codes listed in the award are authorized.\nNew Tests:\nmay be added to the award through a bi-lateral modification.  \nshall not be utilized until a bilateral modification is executed.\npricing shall not change for any test replaced due to a test code/description change.\nTests Not Listed in the Award\nTests not listed in this award with the assigned test code/description are not authorized.\nAny test not listed or authorized shall follow a separate process unrelated to this agreement or through VA Community Care.\nContractor shall not process any test not listed in the award nor request payment for tests not listed through this agreement.  Contractor risks non-payment of any test not authorized.\nEstablished Process for Non-Listed Test Codes/Descriptions (Non-Contracted):\nContractor shall set up a Non-Contracted Account Number\nAll Non-Contracted Tests shall not be processed without proper authorization prior to the test being processed.\n\nEMPLOYMENT AND LIABILITY\nThis is a non-personnel services contract. The Contractor shall be responsible for protecting the personnel furnishing services under this contract.  To carry out this responsibility, the Contractor shall provide the following for these personnel, which includes worker s compensation, professional liability insurance, health examinations, income tax withholding and social security payments. The parties agree that Contractor personnel without formal appointments shall not be considered VA employees for any purpose and shall be considered employees of the Contractor\n\nINFECTION CONTROL\nContracted patient care activities shall be integrated into the participating Facility  Infection Control program, and contract staff shall adhere to the Facility Infection Control policies and procedures. The Facility Infection Control Plan shall identify for the Contractor how risks shall be identified, methods to be used to reduce risk, identification and reporting of community-acquired and nosocomial infections, and data collection and reporting requirements. Reports of surveillance, control, prevention, and monitoring activities performed by the part Facility shall be provided, on a routine basis, to the Contractor.\n\nPATIENT SAFETY\nPatient safety shall be a primary focus of the Contractor including compliance with all applicable patient safety goals.  The participating Facility shall inform the Contractor of all applicable Sentinel Events or other Patient Safety Alerts received by the Facility. For every applicable alert, the Contractor shall take the necessary steps to redesign processes to prevent occurrence and provide written feedback to the Contracting Officer Representative (COR) describing prevention actions taken. All events related to patient injury, medication errors, and other breeches of patient safety shall be documented utilizing the Contractor s format and reported to the COR utilizing the part Facility  Incident Report. The Facility shall provide the Contractor with the Sentinel Event definitions in the start-up phase. The Contractor shall verbally notify the Facility COR immediately when a Sentinel Event has occurred, which is to be followed by written notification within one (1) business day or sooner if requested by the medical center. The Facility shall determine when a Root Cause Analysis (RCA) is required of the Contractor. The Contractor shall conduct all Root Cause Analysis according to the Facility policy and within established time frames (45 days). Completed RCAs shall be provided to the Facility COR.\n\nPATIENT RIGHTS\nProtection of all patients  rights is of highest priority. Patient privacy and confidentiality shall be maintained at all times. Computer access shall be granted on a need-to-know basis, and security of computerized information shall be maintained at all times. No patients shall be subject to any research activity without his fully informed consent, subject to study approval by the Investigational Research Board (IRB). The Contractor shall abide by the participating Facility  Code of Ethics, which addresses marketing, admission/transfer/referral/discharge processes, and billing issues. The Contractor and the patient care service provided shall be included in the participating Facility data collection activities related to patient and family complaints and satisfaction issues. Care provided shall respect and integrate the patient s beliefs, values, and cultural influences\n\nGOVERNMENT RESPONSIBILITIES\nCONTRACT PERFORMANCE MONITORING\nContractor's employee(s) shall report to the Laboratory Central Processing area, upon arrival at the VA for specimen pickup.  \nMonitoring of contractor s performance shall be demonstrated through clinical and administrative record reviews.  COR will be responsible for verifying contract compliance.  Contracting Officer's Representative(s) (COR) will designate appropriate VA personnel to monitor services through one or a combination of the following mechanisms:\nDepartments being served will monitor Contractor performance to ensure that services called for in the contract have been received by VA in a timely manner. Any incidents of Contractor noncompliance as evidenced by the monitoring procedures will be forwarded immediately to the Contracting Officer.\nDocumentation of services performed will be reviewed prior to certifying payment.  The COR will perform periodic spot checks and document with the using service to ensure records monitoring.  VA will pay only for services actually provided, and in strict accordance with the Price/Cost Schedule.  Contract monitoring and recordkeeping procedures will be sufficient to ensure proper payment and allow audit verification that services were provided.  \nDepartments being served, through the COR(s), will provide a written statement annually to the Contracting Officer to include a summary of Contractor actions and a statement that all requirements of the contract have been fulfilled as agreed.  This summary evaluation will be submitted 45 days prior to expiration of contract (and/or prior to ordering periods, if applicable).\n\nQUALITY ASSURANCE MONITORING\nContractor shall maintain a Quality Assurance Program related to Reference Laboratory services covered under this contract.  \nContractor shall also participate in a joint quality assurance surveillance program (QASP) with the Government facilities.  This program must minimally address the quality aspects representative to the testing process, i.e., pre-analytical, analytical, and post-analytical variables and include a description of monitoring and evaluation activities.  There must be a mutually agreed upon procedure for responding to issues, problems and/or concerns identified by the Government with details as to whom and in what timeframe the matters will be reconciled.  The issues that may need to be addressed may be general in nature or specific to an incident or event.  The contractor will meet or communicate with the facility/VISN staff for process review and improvement of contract performance on an as needed basis.   \nCopies of licensure/certifications are also required to be submitted upon request by the VA.\n\nPERFORMANCE STANDARDS\nLicensing, Accreditation, & Certification\nPerformance Requirement: Contractor shall maintain and provide CLIA Certification, CAP Accreditation, or equivalent; along with applicable OSHA, Federal, and State Laws for all laboratories, including any subcontractors.\nStandard: Proper certifications shall be kept up to date for the entire performance of this agreement.  This includes all ordering periods.\nAcceptable Quality Level (AQL): 100% Meets Standard, no deviations are authorized.\nSurveillance Method: Periodic Sampling \nFrequency: Contractor shall provide all requested Licenses, Accreditations, and Certifications upon request of the Government at any time for all laboratories, to include all subcontractors.\nTechnical Quality\nPerformance Requirement: Produce high-quality, consistent access to reports, test code changes, errors in technical transmission issues.\nStandard: Meets quality requirements.\nAcceptable Quality Level (AQL): 95% Meets Standard\nSurveillance Method: Quarterly Review\nFrequency: COR to review issues with interfacing and notifications of test code changes, issues with test code results.\nTimeliness\nPerformance Requirement: Processes specimens and report test results within the stated turn-around-times.\nStandard: Timely courier pick-ups, specimen processing and reporting of all test results.\nAcceptable Quality Level (AQL): 90% Meets Standard\nSurveillance Method: Periodic Sampling\nFrequency: COR will review monthly reports\nTest Accuracy\nPerformance Requirement: Contractor shall provide accurate testing in accordance with the tests, test codes, test descriptions, specimen processing, and test results.\nStandard: Number of modified test results, not due to incorrect requisition information from referring lab.\nAcceptable Quality Level (AQL): < 0.02% of all patient results received.\nSurveillance Method: Monthly review\nFrequency: COR will review monthly reports.\nTransportation & Sample Integrity\nPerformance Requirement: Transportation and Quality standards outlined in the Performance Work Statement (PWS).\nStandard: Ensures integrity of samples during transportation to the performing laboratory.\nAcceptable Quality Level (AQL): < 3 lost specimens.\nSurveillance Method: Monthly review.\nFrequency: COR will review monthly reports and courier pick-up logs.\nAnatomic Pathology Random Review\nPerformance Requirement: Contractor shall perform retrospective case review.\nStandard: Staff pathologist to provide case reviews of 10% of all cases for pathology, surgical, cytology, hematopathology, mohs, and fine needle aspirate, etc.\nAcceptable Quality Level (AQL): 100% review and documenting of 10% of all cases.\nSurveillance Method: Monthly review\nFrequency: Contractor shall provide a monthly report to each facility COR providing all results of each review completed.\nBilling and Invoicing\nPerformance Requirement: Contractor shall ensure only tests listed in the award (test codes and descriptions) are billed through the award account.  Contractor shall ensure that they meet all invoicing and billing requirements established in the award.\nStandard: Proper and correct invoicing.\nAcceptable Quality Level (AQL): 90%\nSurveillance Method: Monthly review.\nFrequency: Contractor shall submit on-time invoices with all required information monthly as established in this award.\nTracking Purchase Card Transactions\nPerformance Requirement: Contractor shall follow the procedures in Attachment 7 \nStandard: Proper and correct tracking and notification of test results delivery and payment\nAcceptable Quality Level (AQL): 90%\nSurveillance Method: Monthly Review \nFrequency: Contractor shall submit monthly tracking spreadsheet as established in Attachment 7 \n\nCONTRACT INCREASES UP TO 20% OF TOTAL CONTRACT VALUE\nDue to the unpredictable nature of the quantities and types of tests that will be required, any estimations will fall short of accurate. Therefore, the VA reserves the right to increase the total value of the contract up to no more than 20% of the total contract value by increasing the estimated quantities of tests required, and/or adding new tests to the list via a supplemental agreement in accordance with FAR 52.212-4. These modifications will occur on an estimated quarterly basis.\n\nINVOICING INSTRUCTIONS \nInvoice requirements and supporting documentation: Supporting documentation and invoice must be submitted no later than the 20th workday of the month for the month prior. Subsequent changes or corrections shall be submitted by separate invoice. In addition to information required for submission of a  proper  invoice in accordance with FAR 52.212-4 (g), all invoices must include:\nName and Address of Contractor\nInvoice Date and Invoice Number\nContract Number and Purchase/Task Order Number\nDate of Service\nInvoices shall not include any PII such as full name, social security number, or date of birth.Â \nAttached Excel spreadsheet  Reference Lab Invoice Summary  for each month with the total quantity for the corresponding invoice (this shall include every test in order as they appear in the award, even if the total is zero for that month).\nInvoices shall include the correct PO.\n Invoices shall be submitted electronically through Tungsten Services and be certified by VA COR for payment.\nAny test code names and/or quantities on a contract invoice that was paid for using a purchase card transaction will cause the invoice to be rejected in it s entirety. \nAny test code names and/or quantities that were not able to be provided due to specimen integrity failure will cause the invoice to be rejected in it s entirety.\nWhen invoicing, prior to the test name being updated via contract modification, the Contractor shall reference both the previous test code name and new test code name on the invoice.","origin":"detail"},"contacts":[{"name":"Morgan Stein","role":"primary","email":"Morgan.Stein@va.gov","title":"Contract Specialist"}],"place_of_performance":{"zip":"49037","city":{"name":"Battle Creek"},"state":{"name":"MI"},"street":"Department of Veteran's Affairs","country":{"code":"USA","name":"UNITED STATES"},"street2":"Battle Creek VA Medical Center 5500 Armstrong Road"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"naics_codes":["621511"],"award":{"awardee":{}},"attachments":[{"resource_id":"cfaa7cd86ebf41de87d2cc15cdbeacad","name":"36C25025Q0255.docx","kind":"file","mime_type":".docx","size_bytes":19759,"posted_at":"2025-02-11T16:48:48.884Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/cfaa7cd86ebf41de87d2cc15cdbeacad/download","mirrored":false},{"resource_id":"18447cc27aa24a688f35237f1328a6e2","name":"Website","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2025-02-11T16:48:48.884Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov","mirrored":false},{"resource_id":"a39f39e1f4f44beca9bf0f0c5f4beaf6","name":"36C25025Q0255 LineItems.xlsx","kind":"file","mime_type":".xlsx","size_bytes":1470665,"posted_at":"2025-02-11T16:48:48.884Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/a39f39e1f4f44beca9bf0f0c5f4beaf6/download","mirrored":false},{"resource_id":"47367e40da2c4b03ab8fd9f9b0b9906a","name":"36C25025Q0255 0001.docx","kind":"file","mime_type":".docx","size_bytes":68273,"posted_at":"2025-02-11T21:00:09.387Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/47367e40da2c4b03ab8fd9f9b0b9906a/download","mirrored":false}],"awards":[],"related":[{"key":"36C25027Q0113","latest_notice_id":"30f6d444e0f641e5b23d5b4c1ec5a384","title":"Q301--Prostate Reference Lab Testing Services","solicitation_number":"36C25027Q0113","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-25T21:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"621511","psc":"Q301","set_aside":null,"state":"OH","county":"39049","county_name":"Franklin County","city":"3918000","city_name":"Columbus","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C25027Q0014","latest_notice_id":"b13cc87179e947e7b42da2de44a6bde1","title":"J061--541 Electrical Power Distribution Equipment Testing, Inspection, and Maintenance - VAMC Cleveland","solicitation_number":"36C25027Q0014","notice_type":"k","first_type":"k","first_posted":"2026-10-09","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"238210","psc":"J061","set_aside":"SBA","state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C25027Q0123","latest_notice_id":"fb53a332644a4c8fa983bf28c8643d2d","title":"S222--Sources Sought - Hazardous Waste Removal/Disposal Northeast Ohio VA Healthcare System - Cleveland, OH","solicitation_number":"36C25027Q0123","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T18:30:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"562112","psc":"S222","set_aside":null,"state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C25027B0009","latest_notice_id":"85b83d408f1f422885991142c2734b45","title":"Z1DA--FY27 NRM - VISN Base Modernize Nurse Call - 539-23-101","solicitation_number":"36C25027B0009","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"},{"key":"36C25027B0008","latest_notice_id":"5afe716a38494a6f84b1e84205805f86","title":"Z1DA--FY27 NRM - VISN Base Install Roof Equipment Railings - 539-22-206","solicitation_number":"36C25027B0008","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"}],"similar_open":[{"key":"36C25027Q0113","latest_notice_id":"30f6d444e0f641e5b23d5b4c1ec5a384","title":"Q301--Prostate Reference Lab Testing Services","solicitation_number":"36C25027Q0113","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-25T21:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"621511","psc":"Q301","set_aside":null,"state":"OH","county":"39049","county_name":"Franklin County","city":"3918000","city_name":"Columbus","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C26326R0063","latest_notice_id":"d70c843cc4d84fd69905d2e17ce78771","title":"NWI Offsite Pathology Services","solicitation_number":"36C26326R0063","notice_type":"o","first_type":"o","first_posted":"2026-10-09","last_posted":"2026-11-20","notices":5,"due_at":"2026-11-30T16:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C263","office_name":"NETWORK CONTRACT OFFICE 23 (36C263)","naics":"621511","psc":"Q515","set_aside":"SBA","state":"NE","county":"31055","county_name":"Douglas County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"N0018927R0001","latest_notice_id":"63940568a9a1466e83c3068f740e6182","title":"NBIMC Bloodborne Services","solicitation_number":"N0018927R0001","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-09T21:00:00Z","due_date":"2026-12-09","closes_at":"2026-12-09T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00189","office_name":"NAVSUP FLT LOG CTR NORFOLK","naics":"621511","psc":"Q301","set_aside":null,"state":"MD","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"DEFENSE SERUM REPOSITORY (DODSR) IN SILVER SPRING, MARYLAND","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":5,"indexable":false}