{"canonical":"https://sealedbidder.com/opportunities/36c25025q0148","key":"36C25025Q0148","url":"https://sealedbidder.com/opportunities/36c25025q0148","title":"6640--Protein Electrophoresis System (Ann Arbor VA Medical Center)","solicitation_number":"36C25025Q0148","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-02-18T17:00:00Z","first_posted":"2025-02-11","last_posted":"2025-02-11","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"334516","psc":"6640","set_aside":null,"place_state":"MI","place_scope":"nationwide","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"26161","place_county_name":"Washtenaw County","place_city":"2603000","place_city_name":"Ann Arbor","winner":null,"award_amount":null,"publications":[{"notice_id":"6e587ba411624ed0ad804c8f2955d77f","title":"6640--Protein Electrophoresis System (Ann Arbor VA Medical Center)","solicitation_number":"36C25025Q0148","notice_type":"r","base_type":"r","posted":"2025-02-11","posted_at":"2025-02-11T16:52:39.940Z","due_at":"2025-02-18T17:00:00Z","due_date":"2025-02-18","cancelled":false,"archived":true,"archive_date":"2025-03-20","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/6e587ba411624ed0ad804c8f2955d77f/view","enriched":true,"history":[{"index":3,"title":"6640--Protein Electrophoresis System (Ann Arbor VA Medical Center)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-11T16:52:39.940Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"6e587ba411624ed0ad804c8f2955d77f","solicitation_number":"36C25025Q0148"}]}],"latest_notice_id":"6e587ba411624ed0ad804c8f2955d77f","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-02-11","posted_at":"2025-02-11T16:52:39.940Z","created_at":"2025-02-11T16:52:37.716Z","modified_at":"2025-03-21T03:55:44.754Z","response_deadline":{"raw":"2025-02-18T12:00:00-05:00","utc":"2025-02-18T17:00:00Z","date":"2025-02-18","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/6e587ba411624ed0ad804c8f2955d77f/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"6640--Protein Electrophoresis System (Ann Arbor VA Medical Center)","agency":{"office":{"code":"36C250","name":"250-NETWORK CONTRACT OFFICE 10 (36C250)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"organization_id":"100167099","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-03-20","archive_type":"auto_custom"},"history":[{"index":3,"title":"6640--Protein Electrophoresis System (Ann Arbor VA Medical Center)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-11T16:52:39.940Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"6e587ba411624ed0ad804c8f2955d77f","solicitation_number":"36C25025Q0148"}],"contacts":[{"name":"Contracting Officer","role":"primary","email":"james.howard3@va.gov","title":"James Howard"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"6e587ba411624ed0ad804c8f2955d77f","lineage_id":"6e587ba411624ed0ad804c8f2955d77f","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-23T00:00:16.748686434Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"debae56544204c7601eee631f3fb0ab9ff33623e3370db4352290c325a28b6ad","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-23T00:00:16.748686434Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"This is a SOURCES SOUGHT only for the Ann Arbor VA Medical Center. Information collected during this Sources Sought may be used in a set aside. If a solicitation is issued, the Government will do so in accordance with Federal Acquisition Circular (FAC) 2024-03. The North American Industry Classification System (NAICS) number is 325413. The NAICS size is 1,500 employees. Preliminary contract scope will be a 5-year Blanket Purchase Agreement with four option years.\n\nAny contractor that believes they are capable of meeting the requirements below, and desire to claim preference for small business status, must be registered with the SBA and be able to be located through SBA - Dynamic Small Business Search. Any contractor that believes they are capable and desires to claim preference for veteran owned small business status must be registered with in VetCert at Veteran Small Business Certification (sba.gov) as an SDVOSB or VOSB. \nAll contractors that deem themselves capable of meeting the requirement shall provide the below information to James Howard, Contracting Officer, at james.howard3@va.gov no-later-than Tuesday, February 18, 2025, at 12:00PM, EDT, and referencing RFI #36C25025Q0148. Responses shall include: (1) Business Name and Address, (2) Contract Number items are covered under, if applicable (3) Point of Contact Name, Phone Number and E-mail Address (4) SAM UEI and NAICS code (5) Business Size SMALL or LARGE (6) Type of Business: service disabled veteran owned, veteran owned small business, 8a, HUBZone, woman-owned, etc. (7) Information for the product you would propose and which, if any, of the salient characteristics below it does not meet. (8) Where the proposed product(s) are manufactured. (9) A concern that is not a manufacturer of the commodity shall provide the manufacturer s name and size standard, along with an authorized distributor letter. (10) If the concern is the manufacture and the sole distributor, please provide documentation to that effect. If the concern is the manufacturer and has authorized distributors, please provide a list of the authorized distributors as well. (11) Current lead time of equipment that will be proposed. \n\nContractor must be registered with https://www.sam.gov\nTo be considered SDVOSB/VOSB, must be registered in VetCert at Veteran Small Business Certification (sba.gov).\nFOB is Destination.\nDelivery is to:\n\nAnn Arbor VAMC (Chemistry Laboratory)\n2215 Fuller Rd.\nAnn Arbor, MI 48105\n\n\n\n\n\n\nSALIENT CHARACTERISTICS\n\nPROTEIN ELECTROPHORESIS SYSTEM\n\nSYSTEM & CONSUMABLE REQUIREMENTS:\n\nTest Menu MUST include test kits for the various assays involved in:\n\nSerum Protein Electrophoresis (SPEP): Fractionation of various proteins in serum.\nImmunotyping (IT): Identification of abnormal proteins in serum and urine\nImmunofixation (I-Fix): Identification of abnormal proteins in human serum, urine and/or other biological fluids.\nUrine Protein Electrophoresis (UPEP): Fractionation of various proteins in urine- Qualitative analysis\nDetection and identification of gammopathies in human sera and other biological fluids.\nDetection and identification of Bence Jones protein in human urine or of free light chains in human serum      \nHigh Resolution (HR) multifractionation of proteins in neat or diluted human serum, urine, or concentrated cerebrospinal fluid.\nProvide upgrades for new tests as available.\n           \nCapillary/Gel system must have automatic delimiting of curves and identification of fractions to minimize operator editing.      \n\nCapillary/Gel system must have the ability to import quantitative specific protein results with correct measuring unit required to provide a comprehensive chartable report. System must have patient s demographic information available. \n\nCapillary/Gel system must be able to import comment(s) from a word processor for unlimited comment entry.  \n\nCapillary/Gel system must allow for customized, compressed printouts of results and curves. \n \nThe Capillary/Gel electrophoresis is the technique employed in the separation of proteins.  Proteins are detected directly at a precise wavelength providing a high degree of precision and accuracy.\n\nThe Capillary/Gel system must have eight capillary tubes, which will increase throughput.   \n\nThe Capillary/Gel system must provide walk-away technology from start to finish.  System must have the capability to read barcodes and provide for a continuous feed of samples. The system must have Positive Sample Identification (PSI) capability for full traceability from primary tube placement to final result recovery. \n\nThe Capillary/Gel system must have a system that controls the temperature during sample migration for consistent reproducibility from analysis-to-analysis and from capillary to-capillary. \n\nThe Capillary/Gel system must process approximately 80 samples per hour.\n\nThe Capillary/Gel system must have reagent traceability technology.\n\nAn interpretive software package must be available to facilitate reporting of results.\n\nA Personal Computer (PC), keyboard, mouse, monitor, imaging scanner and high-definition color printer must be provided with connection cables for communication between the Capillary and agarose gel electrophoresis systems. This will allow for importing and storage of immunofixation scans and Capillary/Gel results and images.    \n\nThe automated multiparametric agarose gel electrophoresis instrument must have high resolution and clarity of the electrophoresis bands for easy interpretation. The densitometry system is integrated into the instrument. The software provides editing and quantification of results, customization of reports, archival and recall of patient results.  The system must have a color LCD touch-screen display. Vendor must update the latest version of software as available to the customers free of charge.\n\nThe automated multiparametric agarose gel electrophoresis system must provide a sequential processing of each electrophoresis step from application, migration, incubation, staining, destaining, drying, and final reading allowing for  walk-away  operation.  \n\nThe automated multiparametric agarose gel electrophoresis system throughput should be at least 80 protein samples per hour and at least 15 Immunofixation samples per hour.  \n\nThe automated multiparametric agarose gel electrophoresis system must automatically regulate voltage, current, power and volt hour, and stable temperature for consistent results from agarose gel to agarose gel.    \n\nThe automated multiparametric agarose gel electrophoresis system must have an easy-to-use keyboard and screen with up to 40 migration programs available.   \n\nThe automated multiparametric agarose gel electrophoresis system must have at least 8 different reagents on-line that are available at once.  Reagents need to be water based. \n \nThe system must have a processing system for sample preparation and dilution designed to complement the automated multiparametric agarose gel electrophoresis system. A processing system must deliver precise micro-volumes of sample directly from primary tubes to the sample applicators, therefore allowing accurate and precise delivery of sample to agarose gel.\n\nAutomated multiparametric agarose gel electrophoresis system must compress printouts of results and curves and allow the operator to customize the report(s). \nAutomated multiparametric agarose gel electrophoresis system must be able to import comments from a word processor for customizable comment entry.  Report options should include item such as patient history, immunofixation image, UID, name, age, ordering physician, specimen collection date and time.\n  \nAutomated multiparametric agarose gel electrophoresis system must have a three-level quality control per analysis program, and Levey-Jennings statistical program. \n\nThe Capillary/Gel and Automated multiparametric agarose gel electrophoresis system must have bidirectional (broadcast download & host query) Laboratory Information System (LIS) capabilities.  \n \nAutomated multiparametric agarose gel electrophoresis system must have software to allow for extensive curve editing capabilities, including deletion of minima and fractions, baseline modifications, fraction identification, and curve overlay. System must also have automatic alignment, centering of the electrophoretic pattern during reading, and automatic demarcation of the electrophoretic patterns.    \n\nAn auto-sampler is a must for full standardization of all pre-analytical steps associated with the agarose gel electrophoresis system. The auto sampler must have Positive Sample Identification (PSI) capabilities.\n \nAll systems that have Positive Sample Identification (PSI) must be able to utilize and read barcode type: Code 128.  \n\nAll systems must be compatible with 110   120 Volt power outlets.\n\nMust have adequate Uninterruptible Power System (UPS) to support each analyzer system.\n\nEach system must have an on-board type of waste disposable system for liquid output with options of connecting to floor drains.\n \nSampling systems must accommodate primary sample tubes sizes of 13mm x 75mm; 13 mm x 100 mm; and 16 mm x 100 mm; 5, 7, 10 mL tubes, and micro tubes.  Systems must be able to accept plastic tubes meeting current safety requirements.\n \nSystem and tests must meet College of America Pathologists (CAP), Clinical Laboratory Improvement Act of 1988 (CLIA  88), Clinical and Laboratory Standards Institute (CLSI; formerly NCCLS) standards and demonstrate satisfactory performance on CAP peer group comparisons.\n\nSystem must be able to analyze serum, urine, and cerebrospinal fluid (CSF) when applicable/dependent on the electrophoresis process. \n\nSystem must have cap piercing mechanism.\n\nSystem must be capable of integrating the workstation to pathologist s desk.\n\n\n\n\n\n\nProjected Test Volumes","text":"This is a SOURCES SOUGHT only for the Ann Arbor VA Medical Center. Information collected during this Sources Sought may be used in a set aside. If a solicitation is issued, the Government will do so in accordance with Federal Acquisition Circular (FAC) 2024-03. The North American Industry Classification System (NAICS) number is 325413. The NAICS size is 1,500 employees. Preliminary contract scope will be a 5-year Blanket Purchase Agreement with four option years.\n\nAny contractor that believes they are capable of meeting the requirements below, and desire to claim preference for small business status, must be registered with the SBA and be able to be located through SBA - Dynamic Small Business Search. Any contractor that believes they are capable and desires to claim preference for veteran owned small business status must be registered with in VetCert at Veteran Small Business Certification (sba.gov) as an SDVOSB or VOSB.\nAll contractors that deem themselves capable of meeting the requirement shall provide the below information to James Howard, Contracting Officer, at james.howard3@va.gov no-later-than Tuesday, February 18, 2025, at 12:00PM, EDT, and referencing RFI #36C25025Q0148. Responses shall include: (1) Business Name and Address, (2) Contract Number items are covered under, if applicable (3) Point of Contact Name, Phone Number and E-mail Address (4) SAM UEI and NAICS code (5) Business Size SMALL or LARGE (6) Type of Business: service disabled veteran owned, veteran owned small business, 8a, HUBZone, woman-owned, etc. (7) Information for the product you would propose and which, if any, of the salient characteristics below it does not meet. (8) Where the proposed product(s) are manufactured. (9) A concern that is not a manufacturer of the commodity shall provide the manufacturer s name and size standard, along with an authorized distributor letter. (10) If the concern is the manufacture and the sole distributor, please provide documentation to that effect. If the concern is the manufacturer and has authorized distributors, please provide a list of the authorized distributors as well. (11) Current lead time of equipment that will be proposed.\n\nContractor must be registered with https://www.sam.gov\nTo be considered SDVOSB/VOSB, must be registered in VetCert at Veteran Small Business Certification (sba.gov).\nFOB is Destination.\nDelivery is to:\n\nAnn Arbor VAMC (Chemistry Laboratory)\n2215 Fuller Rd.\nAnn Arbor, MI 48105\n\nSALIENT CHARACTERISTICS\n\nPROTEIN ELECTROPHORESIS SYSTEM\n\nSYSTEM & CONSUMABLE REQUIREMENTS:\n\nTest Menu MUST include test kits for the various assays involved in:\n\nSerum Protein Electrophoresis (SPEP): Fractionation of various proteins in serum.\nImmunotyping (IT): Identification of abnormal proteins in serum and urine\nImmunofixation (I-Fix): Identification of abnormal proteins in human serum, urine and/or other biological fluids.\nUrine Protein Electrophoresis (UPEP): Fractionation of various proteins in urine- Qualitative analysis\nDetection and identification of gammopathies in human sera and other biological fluids.\nDetection and identification of Bence Jones protein in human urine or of free light chains in human serum\nHigh Resolution (HR) multifractionation of proteins in neat or diluted human serum, urine, or concentrated cerebrospinal fluid.\nProvide upgrades for new tests as available.\n\nCapillary/Gel system must have automatic delimiting of curves and identification of fractions to minimize operator editing.\n\nCapillary/Gel system must have the ability to import quantitative specific protein results with correct measuring unit required to provide a comprehensive chartable report. System must have patient s demographic information available.\n\nCapillary/Gel system must be able to import comment(s) from a word processor for unlimited comment entry.\n\nCapillary/Gel system must allow for customized, compressed printouts of results and curves.\n\nThe Capillary/Gel electrophoresis is the technique employed in the separation of proteins. Proteins are detected directly at a precise wavelength providing a high degree of precision and accuracy.\n\nThe Capillary/Gel system must have eight capillary tubes, which will increase throughput.\n\nThe Capillary/Gel system must provide walk-away technology from start to finish. System must have the capability to read barcodes and provide for a continuous feed of samples. The system must have Positive Sample Identification (PSI) capability for full traceability from primary tube placement to final result recovery.\n\nThe Capillary/Gel system must have a system that controls the temperature during sample migration for consistent reproducibility from analysis-to-analysis and from capillary to-capillary.\n\nThe Capillary/Gel system must process approximately 80 samples per hour.\n\nThe Capillary/Gel system must have reagent traceability technology.\n\nAn interpretive software package must be available to facilitate reporting of results.\n\nA Personal Computer (PC), keyboard, mouse, monitor, imaging scanner and high-definition color printer must be provided with connection cables for communication between the Capillary and agarose gel electrophoresis systems. This will allow for importing and storage of immunofixation scans and Capillary/Gel results and images.\n\nThe automated multiparametric agarose gel electrophoresis instrument must have high resolution and clarity of the electrophoresis bands for easy interpretation. The densitometry system is integrated into the instrument. The software provides editing and quantification of results, customization of reports, archival and recall of patient results. The system must have a color LCD touch-screen display. Vendor must update the latest version of software as available to the customers free of charge.\n\nThe automated multiparametric agarose gel electrophoresis system must provide a sequential processing of each electrophoresis step from application, migration, incubation, staining, destaining, drying, and final reading allowing for walk-away operation.\n\nThe automated multiparametric agarose gel electrophoresis system throughput should be at least 80 protein samples per hour and at least 15 Immunofixation samples per hour.\n\nThe automated multiparametric agarose gel electrophoresis system must automatically regulate voltage, current, power and volt hour, and stable temperature for consistent results from agarose gel to agarose gel.\n\nThe automated multiparametric agarose gel electrophoresis system must have an easy-to-use keyboard and screen with up to 40 migration programs available.\n\nThe automated multiparametric agarose gel electrophoresis system must have at least 8 different reagents on-line that are available at once. Reagents need to be water based.\n\nThe system must have a processing system for sample preparation and dilution designed to complement the automated multiparametric agarose gel electrophoresis system. A processing system must deliver precise micro-volumes of sample directly from primary tubes to the sample applicators, therefore allowing accurate and precise delivery of sample to agarose gel.\n\nAutomated multiparametric agarose gel electrophoresis system must compress printouts of results and curves and allow the operator to customize the report(s).\nAutomated multiparametric agarose gel electrophoresis system must be able to import comments from a word processor for customizable comment entry. Report options should include item such as patient history, immunofixation image, UID, name, age, ordering physician, specimen collection date and time.\n\nAutomated multiparametric agarose gel electrophoresis system must have a three-level quality control per analysis program, and Levey-Jennings statistical program.\n\nThe Capillary/Gel and Automated multiparametric agarose gel electrophoresis system must have bidirectional (broadcast download & host query) Laboratory Information System (LIS) capabilities.\n\nAutomated multiparametric agarose gel electrophoresis system must have software to allow for extensive curve editing capabilities, including deletion of minima and fractions, baseline modifications, fraction identification, and curve overlay. System must also have automatic alignment, centering of the electrophoretic pattern during reading, and automatic demarcation of the electrophoretic patterns.\n\nAn auto-sampler is a must for full standardization of all pre-analytical steps associated with the agarose gel electrophoresis system. The auto sampler must have Positive Sample Identification (PSI) capabilities.\n\nAll systems that have Positive Sample Identification (PSI) must be able to utilize and read barcode type: Code 128.\n\nAll systems must be compatible with 110 120 Volt power outlets.\n\nMust have adequate Uninterruptible Power System (UPS) to support each analyzer system.\n\nEach system must have an on-board type of waste disposable system for liquid output with options of connecting to floor drains.\n\nSampling systems must accommodate primary sample tubes sizes of 13mm x 75mm; 13 mm x 100 mm; and 16 mm x 100 mm; 5, 7, 10 mL tubes, and micro tubes. Systems must be able to accept plastic tubes meeting current safety requirements.\n\nSystem and tests must meet College of America Pathologists (CAP), Clinical Laboratory Improvement Act of 1988 (CLIA 88), Clinical and Laboratory Standards Institute (CLSI; formerly NCCLS) standards and demonstrate satisfactory performance on CAP peer group comparisons.\n\nSystem must be able to analyze serum, urine, and cerebrospinal fluid (CSF) when applicable/dependent on the electrophoresis process.\n\nSystem must have cap piercing mechanism.\n\nSystem must be capable of integrating the workstation to pathologist s desk.\n\nProjected Test Volumes","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25025Q0148","place_of_performance":{"zip":"48105","city":{"name":"Ann Arbor"},"state":{"name":"MI"},"street":"Department of Veterans Affairs Veterans Health Administration","country":{"code":"USA","name":"UNITED STATES"},"street2":"Ann Arbor VA Medical Center 2215 Fuller Rd."},"product_service_code":"6640"}],"due_at":"2025-02-18T17:00:00Z","due_date":"2025-02-18","closes_at":"2025-02-18T17:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","state":"MI","county":"26161","county_name":"Washtenaw County","city":"2603000","city_name":"Ann Arbor","country":"USA","state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-23T01:25:14.149439Z","principal_notice_id":"6e587ba411624ed0ad804c8f2955d77f","description":{"text":"This is a SOURCES SOUGHT only for the Ann Arbor VA Medical Center. Information collected during this Sources Sought may be used in a set aside. If a solicitation is issued, the Government will do so in accordance with Federal Acquisition Circular (FAC) 2024-03. The North American Industry Classification System (NAICS) number is 325413. The NAICS size is 1,500 employees. Preliminary contract scope will be a 5-year Blanket Purchase Agreement with four option years.\n\nAny contractor that believes they are capable of meeting the requirements below, and desire to claim preference for small business status, must be registered with the SBA and be able to be located through SBA - Dynamic Small Business Search. Any contractor that believes they are capable and desires to claim preference for veteran owned small business status must be registered with in VetCert at Veteran Small Business Certification (sba.gov) as an SDVOSB or VOSB.\nAll contractors that deem themselves capable of meeting the requirement shall provide the below information to James Howard, Contracting Officer, at james.howard3@va.gov no-later-than Tuesday, February 18, 2025, at 12:00PM, EDT, and referencing RFI #36C25025Q0148. Responses shall include: (1) Business Name and Address, (2) Contract Number items are covered under, if applicable (3) Point of Contact Name, Phone Number and E-mail Address (4) SAM UEI and NAICS code (5) Business Size SMALL or LARGE (6) Type of Business: service disabled veteran owned, veteran owned small business, 8a, HUBZone, woman-owned, etc. (7) Information for the product you would propose and which, if any, of the salient characteristics below it does not meet. (8) Where the proposed product(s) are manufactured. (9) A concern that is not a manufacturer of the commodity shall provide the manufacturer s name and size standard, along with an authorized distributor letter. (10) If the concern is the manufacture and the sole distributor, please provide documentation to that effect. If the concern is the manufacturer and has authorized distributors, please provide a list of the authorized distributors as well. (11) Current lead time of equipment that will be proposed.\n\nContractor must be registered with https://www.sam.gov\nTo be considered SDVOSB/VOSB, must be registered in VetCert at Veteran Small Business Certification (sba.gov).\nFOB is Destination.\nDelivery is to:\n\nAnn Arbor VAMC (Chemistry Laboratory)\n2215 Fuller Rd.\nAnn Arbor, MI 48105\n\nSALIENT CHARACTERISTICS\n\nPROTEIN ELECTROPHORESIS SYSTEM\n\nSYSTEM & CONSUMABLE REQUIREMENTS:\n\nTest Menu MUST include test kits for the various assays involved in:\n\nSerum Protein Electrophoresis (SPEP): Fractionation of various proteins in serum.\nImmunotyping (IT): Identification of abnormal proteins in serum and urine\nImmunofixation (I-Fix): Identification of abnormal proteins in human serum, urine and/or other biological fluids.\nUrine Protein Electrophoresis (UPEP): Fractionation of various proteins in urine- Qualitative analysis\nDetection and identification of gammopathies in human sera and other biological fluids.\nDetection and identification of Bence Jones protein in human urine or of free light chains in human serum\nHigh Resolution (HR) multifractionation of proteins in neat or diluted human serum, urine, or concentrated cerebrospinal fluid.\nProvide upgrades for new tests as available.\n\nCapillary/Gel system must have automatic delimiting of curves and identification of fractions to minimize operator editing.\n\nCapillary/Gel system must have the ability to import quantitative specific protein results with correct measuring unit required to provide a comprehensive chartable report. System must have patient s demographic information available.\n\nCapillary/Gel system must be able to import comment(s) from a word processor for unlimited comment entry.\n\nCapillary/Gel system must allow for customized, compressed printouts of results and curves.\n\nThe Capillary/Gel electrophoresis is the technique employed in the separation of proteins. Proteins are detected directly at a precise wavelength providing a high degree of precision and accuracy.\n\nThe Capillary/Gel system must have eight capillary tubes, which will increase throughput.\n\nThe Capillary/Gel system must provide walk-away technology from start to finish. System must have the capability to read barcodes and provide for a continuous feed of samples. The system must have Positive Sample Identification (PSI) capability for full traceability from primary tube placement to final result recovery.\n\nThe Capillary/Gel system must have a system that controls the temperature during sample migration for consistent reproducibility from analysis-to-analysis and from capillary to-capillary.\n\nThe Capillary/Gel system must process approximately 80 samples per hour.\n\nThe Capillary/Gel system must have reagent traceability technology.\n\nAn interpretive software package must be available to facilitate reporting of results.\n\nA Personal Computer (PC), keyboard, mouse, monitor, imaging scanner and high-definition color printer must be provided with connection cables for communication between the Capillary and agarose gel electrophoresis systems. This will allow for importing and storage of immunofixation scans and Capillary/Gel results and images.\n\nThe automated multiparametric agarose gel electrophoresis instrument must have high resolution and clarity of the electrophoresis bands for easy interpretation. The densitometry system is integrated into the instrument. The software provides editing and quantification of results, customization of reports, archival and recall of patient results. The system must have a color LCD touch-screen display. Vendor must update the latest version of software as available to the customers free of charge.\n\nThe automated multiparametric agarose gel electrophoresis system must provide a sequential processing of each electrophoresis step from application, migration, incubation, staining, destaining, drying, and final reading allowing for walk-away operation.\n\nThe automated multiparametric agarose gel electrophoresis system throughput should be at least 80 protein samples per hour and at least 15 Immunofixation samples per hour.\n\nThe automated multiparametric agarose gel electrophoresis system must automatically regulate voltage, current, power and volt hour, and stable temperature for consistent results from agarose gel to agarose gel.\n\nThe automated multiparametric agarose gel electrophoresis system must have an easy-to-use keyboard and screen with up to 40 migration programs available.\n\nThe automated multiparametric agarose gel electrophoresis system must have at least 8 different reagents on-line that are available at once. Reagents need to be water based.\n\nThe system must have a processing system for sample preparation and dilution designed to complement the automated multiparametric agarose gel electrophoresis system. A processing system must deliver precise micro-volumes of sample directly from primary tubes to the sample applicators, therefore allowing accurate and precise delivery of sample to agarose gel.\n\nAutomated multiparametric agarose gel electrophoresis system must compress printouts of results and curves and allow the operator to customize the report(s).\nAutomated multiparametric agarose gel electrophoresis system must be able to import comments from a word processor for customizable comment entry. Report options should include item such as patient history, immunofixation image, UID, name, age, ordering physician, specimen collection date and time.\n\nAutomated multiparametric agarose gel electrophoresis system must have a three-level quality control per analysis program, and Levey-Jennings statistical program.\n\nThe Capillary/Gel and Automated multiparametric agarose gel electrophoresis system must have bidirectional (broadcast download & host query) Laboratory Information System (LIS) capabilities.\n\nAutomated multiparametric agarose gel electrophoresis system must have software to allow for extensive curve editing capabilities, including deletion of minima and fractions, baseline modifications, fraction identification, and curve overlay. System must also have automatic alignment, centering of the electrophoretic pattern during reading, and automatic demarcation of the electrophoretic patterns.\n\nAn auto-sampler is a must for full standardization of all pre-analytical steps associated with the agarose gel electrophoresis system. The auto sampler must have Positive Sample Identification (PSI) capabilities.\n\nAll systems that have Positive Sample Identification (PSI) must be able to utilize and read barcode type: Code 128.\n\nAll systems must be compatible with 110 120 Volt power outlets.\n\nMust have adequate Uninterruptible Power System (UPS) to support each analyzer system.\n\nEach system must have an on-board type of waste disposable system for liquid output with options of connecting to floor drains.\n\nSampling systems must accommodate primary sample tubes sizes of 13mm x 75mm; 13 mm x 100 mm; and 16 mm x 100 mm; 5, 7, 10 mL tubes, and micro tubes. Systems must be able to accept plastic tubes meeting current safety requirements.\n\nSystem and tests must meet College of America Pathologists (CAP), Clinical Laboratory Improvement Act of 1988 (CLIA 88), Clinical and Laboratory Standards Institute (CLSI; formerly NCCLS) standards and demonstrate satisfactory performance on CAP peer group comparisons.\n\nSystem must be able to analyze serum, urine, and cerebrospinal fluid (CSF) when applicable/dependent on the electrophoresis process.\n\nSystem must have cap piercing mechanism.\n\nSystem must be capable of integrating the workstation to pathologist s desk.\n\nProjected Test Volumes","html":"This is a SOURCES SOUGHT only for the Ann Arbor VA Medical Center. Information collected during this Sources Sought may be used in a set aside. If a solicitation is issued, the Government will do so in accordance with Federal Acquisition Circular (FAC) 2024-03. The North American Industry Classification System (NAICS) number is 325413. The NAICS size is 1,500 employees. Preliminary contract scope will be a 5-year Blanket Purchase Agreement with four option years.\n\nAny contractor that believes they are capable of meeting the requirements below, and desire to claim preference for small business status, must be registered with the SBA and be able to be located through SBA - Dynamic Small Business Search. Any contractor that believes they are capable and desires to claim preference for veteran owned small business status must be registered with in VetCert at Veteran Small Business Certification (sba.gov) as an SDVOSB or VOSB. \nAll contractors that deem themselves capable of meeting the requirement shall provide the below information to James Howard, Contracting Officer, at james.howard3@va.gov no-later-than Tuesday, February 18, 2025, at 12:00PM, EDT, and referencing RFI #36C25025Q0148. Responses shall include: (1) Business Name and Address, (2) Contract Number items are covered under, if applicable (3) Point of Contact Name, Phone Number and E-mail Address (4) SAM UEI and NAICS code (5) Business Size SMALL or LARGE (6) Type of Business: service disabled veteran owned, veteran owned small business, 8a, HUBZone, woman-owned, etc. (7) Information for the product you would propose and which, if any, of the salient characteristics below it does not meet. (8) Where the proposed product(s) are manufactured. (9) A concern that is not a manufacturer of the commodity shall provide the manufacturer s name and size standard, along with an authorized distributor letter. (10) If the concern is the manufacture and the sole distributor, please provide documentation to that effect. If the concern is the manufacturer and has authorized distributors, please provide a list of the authorized distributors as well. (11) Current lead time of equipment that will be proposed. \n\nContractor must be registered with https://www.sam.gov\nTo be considered SDVOSB/VOSB, must be registered in VetCert at Veteran Small Business Certification (sba.gov).\nFOB is Destination.\nDelivery is to:\n\nAnn Arbor VAMC (Chemistry Laboratory)\n2215 Fuller Rd.\nAnn Arbor, MI 48105\n\n\n\n\n\n\nSALIENT CHARACTERISTICS\n\nPROTEIN ELECTROPHORESIS SYSTEM\n\nSYSTEM & CONSUMABLE REQUIREMENTS:\n\nTest Menu MUST include test kits for the various assays involved in:\n\nSerum Protein Electrophoresis (SPEP): Fractionation of various proteins in serum.\nImmunotyping (IT): Identification of abnormal proteins in serum and urine\nImmunofixation (I-Fix): Identification of abnormal proteins in human serum, urine and/or other biological fluids.\nUrine Protein Electrophoresis (UPEP): Fractionation of various proteins in urine- Qualitative analysis\nDetection and identification of gammopathies in human sera and other biological fluids.\nDetection and identification of Bence Jones protein in human urine or of free light chains in human serum      \nHigh Resolution (HR) multifractionation of proteins in neat or diluted human serum, urine, or concentrated cerebrospinal fluid.\nProvide upgrades for new tests as available.\n           \nCapillary/Gel system must have automatic delimiting of curves and identification of fractions to minimize operator editing.      \n\nCapillary/Gel system must have the ability to import quantitative specific protein results with correct measuring unit required to provide a comprehensive chartable report. System must have patient s demographic information available. \n\nCapillary/Gel system must be able to import comment(s) from a word processor for unlimited comment entry.  \n\nCapillary/Gel system must allow for customized, compressed printouts of results and curves. \n \nThe Capillary/Gel electrophoresis is the technique employed in the separation of proteins.  Proteins are detected directly at a precise wavelength providing a high degree of precision and accuracy.\n\nThe Capillary/Gel system must have eight capillary tubes, which will increase throughput.   \n\nThe Capillary/Gel system must provide walk-away technology from start to finish.  System must have the capability to read barcodes and provide for a continuous feed of samples. The system must have Positive Sample Identification (PSI) capability for full traceability from primary tube placement to final result recovery. \n\nThe Capillary/Gel system must have a system that controls the temperature during sample migration for consistent reproducibility from analysis-to-analysis and from capillary to-capillary. \n\nThe Capillary/Gel system must process approximately 80 samples per hour.\n\nThe Capillary/Gel system must have reagent traceability technology.\n\nAn interpretive software package must be available to facilitate reporting of results.\n\nA Personal Computer (PC), keyboard, mouse, monitor, imaging scanner and high-definition color printer must be provided with connection cables for communication between the Capillary and agarose gel electrophoresis systems. This will allow for importing and storage of immunofixation scans and Capillary/Gel results and images.    \n\nThe automated multiparametric agarose gel electrophoresis instrument must have high resolution and clarity of the electrophoresis bands for easy interpretation. The densitometry system is integrated into the instrument. The software provides editing and quantification of results, customization of reports, archival and recall of patient results.  The system must have a color LCD touch-screen display. Vendor must update the latest version of software as available to the customers free of charge.\n\nThe automated multiparametric agarose gel electrophoresis system must provide a sequential processing of each electrophoresis step from application, migration, incubation, staining, destaining, drying, and final reading allowing for  walk-away  operation.  \n\nThe automated multiparametric agarose gel electrophoresis system throughput should be at least 80 protein samples per hour and at least 15 Immunofixation samples per hour.  \n\nThe automated multiparametric agarose gel electrophoresis system must automatically regulate voltage, current, power and volt hour, and stable temperature for consistent results from agarose gel to agarose gel.    \n\nThe automated multiparametric agarose gel electrophoresis system must have an easy-to-use keyboard and screen with up to 40 migration programs available.   \n\nThe automated multiparametric agarose gel electrophoresis system must have at least 8 different reagents on-line that are available at once.  Reagents need to be water based. \n \nThe system must have a processing system for sample preparation and dilution designed to complement the automated multiparametric agarose gel electrophoresis system. A processing system must deliver precise micro-volumes of sample directly from primary tubes to the sample applicators, therefore allowing accurate and precise delivery of sample to agarose gel.\n\nAutomated multiparametric agarose gel electrophoresis system must compress printouts of results and curves and allow the operator to customize the report(s). \nAutomated multiparametric agarose gel electrophoresis system must be able to import comments from a word processor for customizable comment entry.  Report options should include item such as patient history, immunofixation image, UID, name, age, ordering physician, specimen collection date and time.\n  \nAutomated multiparametric agarose gel electrophoresis system must have a three-level quality control per analysis program, and Levey-Jennings statistical program. \n\nThe Capillary/Gel and Automated multiparametric agarose gel electrophoresis system must have bidirectional (broadcast download & host query) Laboratory Information System (LIS) capabilities.  \n \nAutomated multiparametric agarose gel electrophoresis system must have software to allow for extensive curve editing capabilities, including deletion of minima and fractions, baseline modifications, fraction identification, and curve overlay. System must also have automatic alignment, centering of the electrophoretic pattern during reading, and automatic demarcation of the electrophoretic patterns.    \n\nAn auto-sampler is a must for full standardization of all pre-analytical steps associated with the agarose gel electrophoresis system. The auto sampler must have Positive Sample Identification (PSI) capabilities.\n \nAll systems that have Positive Sample Identification (PSI) must be able to utilize and read barcode type: Code 128.  \n\nAll systems must be compatible with 110   120 Volt power outlets.\n\nMust have adequate Uninterruptible Power System (UPS) to support each analyzer system.\n\nEach system must have an on-board type of waste disposable system for liquid output with options of connecting to floor drains.\n \nSampling systems must accommodate primary sample tubes sizes of 13mm x 75mm; 13 mm x 100 mm; and 16 mm x 100 mm; 5, 7, 10 mL tubes, and micro tubes.  Systems must be able to accept plastic tubes meeting current safety requirements.\n \nSystem and tests must meet College of America Pathologists (CAP), Clinical Laboratory Improvement Act of 1988 (CLIA  88), Clinical and Laboratory Standards Institute (CLSI; formerly NCCLS) standards and demonstrate satisfactory performance on CAP peer group comparisons.\n\nSystem must be able to analyze serum, urine, and cerebrospinal fluid (CSF) when applicable/dependent on the electrophoresis process. \n\nSystem must have cap piercing mechanism.\n\nSystem must be capable of integrating the workstation to pathologist s desk.\n\n\n\n\n\n\nProjected Test Volumes","origin":"detail"},"contacts":[{"name":"Contracting Officer","role":"primary","email":"james.howard3@va.gov","title":"James Howard"}],"place_of_performance":{"zip":"48105","city":{"name":"Ann Arbor"},"state":{"name":"MI"},"street":"Department of Veterans Affairs Veterans Health Administration","country":{"code":"USA","name":"UNITED STATES"},"street2":"Ann Arbor VA Medical Center 2215 Fuller Rd."},"office_address":{"zip":"45428","city":"DAYTON","state":"OH","country":"USA"},"naics_codes":["334516"],"award":{"awardee":{}},"attachments":[{"resource_id":"e06c9f1de18b40d2b2fd2f23e821718e","name":"36C25025Q0148.docx","kind":"file","mime_type":".docx","size_bytes":33982,"posted_at":"2025-02-11T16:52:39.940Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/e06c9f1de18b40d2b2fd2f23e821718e/download","mirrored":false}],"awards":[],"related":[{"key":"36C25027Q0014","latest_notice_id":"b13cc87179e947e7b42da2de44a6bde1","title":"J061--541 Electrical Power Distribution Equipment Testing, Inspection, and Maintenance - VAMC Cleveland","solicitation_number":"36C25027Q0014","notice_type":"k","first_type":"k","first_posted":"2026-10-09","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"238210","psc":"J061","set_aside":"SBA","state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C25027Q0123","latest_notice_id":"fb53a332644a4c8fa983bf28c8643d2d","title":"S222--Sources Sought - Hazardous Waste Removal/Disposal Northeast Ohio VA Healthcare System - Cleveland, OH","solicitation_number":"36C25027Q0123","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T18:30:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"562112","psc":"S222","set_aside":null,"state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C25027B0009","latest_notice_id":"85b83d408f1f422885991142c2734b45","title":"Z1DA--FY27 NRM - VISN Base Modernize Nurse Call - 539-23-101","solicitation_number":"36C25027B0009","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"},{"key":"36C25027B0008","latest_notice_id":"5afe716a38494a6f84b1e84205805f86","title":"Z1DA--FY27 NRM - VISN Base Install Roof Equipment Railings - 539-22-206","solicitation_number":"36C25027B0008","notice_type":"p","first_type":"p","first_posted":"2026-11-08","last_posted":"2026-11-08","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-09T05:16:39.607305Z"},{"key":"36C25027B0005","latest_notice_id":"2cb4a6354be04cc89c5d6125945b1892","title":"Z1DA--***FY27 Requirement*** First Floor X Ray - Room CC157 553-CSI-022","solicitation_number":"36C25027B0005","notice_type":"p","first_type":"p","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"MI","county":"26163","county_name":"Wayne County","city":"2622000","city_name":"Detroit","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"}],"similar_open":[{"key":"FA860127Q0031","latest_notice_id":"f5af57335c7f467ab5c22552405fa16b","title":"NANO-AEROSOL HYGROSCOPICITY- CLOUD CONDENSATION ANALYZER","solicitation_number":"FA860127Q0031","notice_type":"r","first_type":"r","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":"2026-11-27T16:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8601","office_name":"FA8601 AFLCMC PZIO","naics":"334516","psc":"6640","set_aside":null,"state":"OH","county":"39057","county_name":"Greene County","city":"3986660","city_name":"Wright-Patterson AFB","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"NOIOLAOCC27000836","latest_notice_id":"8eb0ea7110504ca7bcc6eb99ffeb6296","title":"Notice of Intent - Illumina MiSeq i100 series instruments","solicitation_number":"NOI-OLAO-CC-27-000836","notice_type":"p","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N900","office_name":"NATIONAL INSTITUTES OF HEALTH - CC","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"80NSSC27949537Q","latest_notice_id":"1cf3a5d3606948079cc677e20c8bf94f","title":"Mechanical Components","solicitation_number":"80NSSC27949537Q","notice_type":"k","first_type":"k","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-27T19:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-080","dept_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","sub_key":"s-8000","sub_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","office_key":"o-80NSSC","office_name":"NASA SHARED SERVICES CENTER","naics":"334516","psc":"5340","set_aside":null,"state":"MS","county":"28045","county_name":"Hancock County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":53,"indexable":false}