Sources sought
Equipment, Essenz Perfusion Systems & Maintenance B+4, Ann Arbor
36C25024Q0508
Department of Veterans Affairs, 250-Network Contract Office 10. Surgical Appliance and Supplies Manufacturing.
Response deadline
April 11, 2024 at 4:30 PM EDT
Closed 960 days ago. Posted April 8, 2024. Scheduled to archive May 11, 2024.
Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities
This one closed in 2024
22 like it are open now in surgical appliance and supplies manufacturing
- VALVE,BREATHING APP
Department of the Navy, NAVSUP Weapon Systems Support Mech
SolicitationNAICS 339113Ship to the buyerN0010427QLA17Due todayNov 27 - REAGENT POWDER
Department of the Navy, NAVSUP Weapon Systems Support Mech
SolicitationNAICS 339113Ship to the buyerN0010426QEJ19Due in 3 daysNov 30 - REMOVABLE CONE,SPEC
Department of the Navy, NAVSUP Weapon Systems Support Mech
SolicitationNAICS 339113Ship to the buyerN0010427QBB84Due in 3 daysNov 30
All 22 open in surgical appliance and supplies manufacturing
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 339113 (surgical appliance and supplies manufacturing), means no more than 800 employees, counted with affiliates. What a set-aside is
- What comes next
- No solicitation was published under this number after the sources sought of April 8, 2024. An agency sometimes issues the solicitation under a new number.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
This is a REQUEST FOR INFORMATION and SOURCES SOUGHT for Essenz Perfusion Systems & Maintenance B+4. This is in preparation for a 5-year, single award, BPA or IDIQ. Contractors that deem themselves capable of meeting the requirement shall provide the below information to Brooke Hansen, Contracting Officer, at Brooke.Hansen@va.gov no-later-than Thursday, April 11, 2024 at 4:30PM, EDT, referencing (36C25024Q0508). Responses shall include:
(1) Business Name and Address, (2) GSA Contract Number and expiration date, if applicable (3) Point of Contact Name, Phone Number and E-mail Address (4) DUNS and NAICS code (5) Business Size SMALL or LARGE (6) Type of Small Business (if applicable): service disabled veteran owned, veteran owned small business, 8a, HUBZone, woman-owned, etc. (7) A concern that is not a manufacturer of the supply shall provide the manufacturers name and size standard (8) Country of Origin. If the concern is the manufacture and the sole distributor, please provide documentation to that effect. Please see requirements below:
LTC Charles S Kettles VA Medical Center, located at 2215 Fuller Road, Ann Arbor, MI, 48105, is requesting the purchase of three LivaNova Essenz Perfusion Systems brand name or equal, to fully support patient care in the OR for cardiothoracic surgeries. The devices and services to be supplied include:
Three (3) Essenz Perfusion Systems brand name or equal these devices are the primary purchase and are used in direct patient care.
The following salient characteristics are required: o State-of-the-art heart-lung machine with an embedded Patient Monitor to implement patient care strategies o Accurate sensing technologies include In-Line Blood Monitor, for data-driven, intra-operative decision making o Quality indicators to support the clinician by monitoring continuously, including trend monitoring and detection of deviations o Appropriate equations for GDP calculation are utilized to provide insightful clinical data o Mast mounted pumps to allow the clinician to optimize the position of the disposables to minimize prime volumes o One knob will only control one per pump o The Perfusion monitor separate from cockpit (so critical real time data will never be obstructed by different viewing menus) o Automated sensor checks confirm the software and hardware are functioning properly before going on bypass o The cockpit must provide color and audible alarms directing attention to appropriate alarm conditions by level of priority Seamless integration with OR external devices and hospital information systems Connectivity options to meet the needs of the hospitals IT infrastructure as well as the clinical documentation requirements, including standard HL7 protocol Advanced Installation for all devices installation to include the ability for the devices to upload pertinent medical data directly to the patient file.
Three (3) Essenz Focus Maintain Service Contracts for 5-year terms (each) brand name or equal this service contract is for annual preventive maintenance that includes regular software upgrades and feature releases. One (1) additional centrifugal pump drive brand name or equal this additional pump is for patient safety in case a pump fails during a procedure. One (1) additional control unit this additional control unit is for patient safety and goes hand-in-hand with the additional pump.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
April 8, 2024
Sources sought
Due April 11, 2024 at 4:30 PM EDT. SAM.gov, notice ee09c930f3c64ec7af14326c2b35651a
Points of contact
- Brooke Hansen, Contract Specialistbrooke.hansen@va.gov269-223-6072