Skip to content

SealedBidder is a private company, not a government agency.

Sign upDashboard
  • 8,715 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell SealedBidder what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and SealedBidder tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $99 a month. See your matches before you pay.
See plans

Sources sought

A/C Replacement Sources Sought Notice

36C25024Q0475

Department of Veterans Affairs, 250-Network Contract Office 10. Plumbing, Heating, and Air-Conditioning Contractors.

Response deadline

April 10, 2024 at 10:00 AM EDT

Closed 960 days ago. Posted March 29, 2024. Scheduled to archive June 9, 2024.

Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities

This one closed in 2024

59 like it are open now in plumbing, heating, and air-conditioning contractors

All 59 open in plumbing, heating, and air-conditioning contractors

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
Who may compete
SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 238220 (plumbing, heating, and air-conditioning contractors), means no more than $19 million in average annual receipts, counted with affiliates. What a set-aside is
What comes next
No solicitation was published under this number after the sources sought of March 29, 2024. An agency sometimes issues the solicitation under a new number.

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov.

GENERAL Ann Arbor VA Medical Center (AAVA) located at 2215 Fuller Road, Ann Arbor, MI 48105, requires replacement of two (2) Liebert air conditioning (A/C) units in Building 1 East, Room CB07. Contractor shall provide all staff, management, supervision, labor, tools, parts, materials and transportation necessary to fully perform the required services.

All work shall be performed by the Contractor aside from VA responsibilities indicated in Section D. SCOPE OF WORK Replacement of current A/C units with two (2) new Liebert A/C units of the same or equivalent quality and performance capability as Liebert Model No. PX029UA 1 AD split system air conditioning units each with a total capacity of 101MBH and a sensible capacity of 89.2 MBH at approximately 75 deg. F, 45% RH. 460V - 3Ph - 60 Hz. 36.0 FLA 43.7 WSA, 50 OPD.

System Details: Up flow with front air return, Liebert iCOM Control with high-definition display; variable speed plug fan; variable capacity, digital scroll compressors utilizing R410-A refrigerant; two stage electric reheat; 7.7lb/hr. humidifier; locking disconnect with; top mount, 3 grille discharge air plenum; air-cooled microchannel condensers.

Liebert MC Condenser Details:

Model: MCM040E1AD 460 Volt, 3 Phase, 60Hz, 1.4 FLA, 1.8 WSA, 15 OPD Microchannel aluminum coil Variable Speed EC Fans Premium electronic control board providing communications with iCOM using CANbus Aluminum exterior panels and 18 aluminum legs Single refrigerant circuit condenser R-401A set points Domestic packaging Short Circuit Current Rating of 65,000 Amps, rms Surge Protective Device for Liebert MC Condenser Required elements/specific tasks: Complete pre-job safety checklist. Perform Lockout/Tagout procedure.

Coordinate with VA staff. Shutdown and disconnect existing equipment. Remove and properly dispose of existing condensers, and any other related parts. Existing evaporators will be abandoned in-place. Properly reclaim all refrigerant from existing equipment. Install new stand-up units. Remove existing stands for condensers and install new rails. Install new condensers. Contractors responsible for any modification to existing piping. Contractor responsible for all electrical and data connections.

Start, test, and check the newly installed equipment for proper operation. Verify all piping is secure and leak-free. Clean up the work area when complete and haul away all debris. Work to be completed in approximately 1 week. CONTRACTOR RESPONSIBILITIES Contractor will be responsible for providing all required equipment which includes but not limited to:

Rigging Equipment. Lifts. Carts or dollies required to transport equipment, materials, and tools. All necessary tools All necessary replacement equipment & parts. All necessary PPE. Personal Lockout/Tagout locks. VA RESPONSIBILITIES/VA WILL PROVIDE Lockout/Tagout of effected equipment. Temporary A/C during project. Location of eyewash/safety showers, alarm pull stations, building exits, emergency procedures. Guidance on vehicle and equipment staging. Verify work has been completed by VA standards.

CONFORMANCE STANDARDS All work in the State of Michigan is required to be performed by a Licensed Mechanical Contractor with a State of Michigan License. All labor practices conform to OSHA rules: proper PPE and Safety Training are required. WARRANTY All materials and installation work will have a one-year warranty period from the date of installation. REPORTING REQUIREMENTS Contractor staff shall report to the Plumbing Shop Supervisor in Building 32 to log in during normal working hours.

Before or after normal working hours, contractor shall report to the Utility Systems Repairer Operator on duty. This check in is mandatory. DAYS/HOURS OF OPERATION Normal working hours are Monday through Friday, 7:00 am to 3:30 pm, excluding federal holidays.

Federal holidays are found at: https://www.opm.gov/policy-data-oversight/pay-leave/federal-holidays/ SAFETY REQUIREMENTS When onsite at AAVA, Contractor shall take such safety precautions as OSHA may determine to be reasonably necessary to protect the lives and health of occupants of the building. The Contracting Officer Representative (COR) shall notify the Contractor of any safety issues and the action necessary to correct these issues.

Such notice, when served on contractor staff at the work site, shall be deemed sufficient for corrective actions to be taken. If the Contractor fails or refuses to comply promptly, the Contracting Officer may issue an order stopping all or part of the work and hold the Contractor in default.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. March 29, 2024

    Sources sought

    Due April 10, 2024 at 10:00 AM EDT. SAM.gov, notice b8182614d4f44fb88cbcab94d6c8da09

Points of contact