{"canonical":"https://sealedbidder.com/opportunities/36c24e26q0082","key":"36C24E26Q0082","url":"https://sealedbidder.com/opportunities/36c24e26q0082","title":"6515--Corneal Esthesiometer Unit","solicitation_number":"36C24E26Q0082","notice_type":"s","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-08-04T20:00:00Z","first_posted":"2026-07-30","last_posted":"2026-08-06","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"RPO EAST (36C24E)","naics":"334516","psc":"6515","set_aside":null,"place_state":null,"place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":"Product purchase (PSC 6515)","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"f8e8f096f3f84417936ffe4a9ed5a518","title":"6515--Non-contact, quantitative corneal esthesiometers","solicitation_number":"36C24E26Q0082","notice_type":"r","base_type":"r","posted":"2026-07-30","posted_at":"2026-07-30T20:53:03.379Z","due_at":"2026-08-04T20:00:00Z","due_date":"2026-08-04","cancelled":false,"archived":true,"archive_date":"2026-08-11","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/f8e8f096f3f84417936ffe4a9ed5a518/view","enriched":true,"history":[{"index":6,"title":"6515--Corneal Esthesiometer Unit","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-06T21:48:53.376Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"cedb9b9d12054de9b0acba8ad48c5c69","solicitation_number":"36C24E26Q0082","related_opportunity_id":"f8e8f096f3f84417936ffe4a9ed5a518"},{"index":4,"title":"6515--Non-contact, quantitative corneal esthesiometers","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-30T20:53:03.379Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"f8e8f096f3f84417936ffe4a9ed5a518","solicitation_number":"36C24E26Q0082"}]},{"notice_id":"cedb9b9d12054de9b0acba8ad48c5c69","title":"6515--Corneal Esthesiometer Unit","solicitation_number":"36C24E26Q0082","notice_type":"s","base_type":"r","posted":"2026-08-06","posted_at":"2026-08-06T21:48:53.376Z","due_at":"2026-08-12T20:00:00Z","due_date":"2026-08-12","cancelled":false,"archived":true,"archive_date":"2026-09-11","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/cedb9b9d12054de9b0acba8ad48c5c69/view","enriched":true,"history":[{"index":6,"title":"6515--Corneal Esthesiometer Unit","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-06T21:48:53.376Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"cedb9b9d12054de9b0acba8ad48c5c69","solicitation_number":"36C24E26Q0082","related_opportunity_id":"f8e8f096f3f84417936ffe4a9ed5a518"},{"index":4,"title":"6515--Non-contact, quantitative corneal esthesiometers","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-30T20:53:03.379Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"f8e8f096f3f84417936ffe4a9ed5a518","solicitation_number":"36C24E26Q0082"}]}],"latest_notice_id":"cedb9b9d12054de9b0acba8ad48c5c69","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-07-30","posted_at":"2026-07-30T20:53:03.379Z","created_at":"2026-07-30T20:53:01.186Z","modified_at":"2026-08-11T05:06:59.878Z","response_deadline":{"raw":"2026-08-04T16:00:00-04:00","utc":"2026-08-04T20:00:00Z","date":"2026-08-04","time":"16:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/f8e8f096f3f84417936ffe4a9ed5a518/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"6515--Non-contact, quantitative corneal esthesiometers","agency":{"office":{"code":"36C24E","name":"RPO EAST (36C24E)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"15212","city":"PITTSBURGH","state":"PA","country":"USA"},"organization_id":"100183218","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-11","archive_type":"auto_custom"},"history":[{"index":6,"title":"6515--Corneal Esthesiometer Unit","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-06T21:48:53.376Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"cedb9b9d12054de9b0acba8ad48c5c69","solicitation_number":"36C24E26Q0082","related_opportunity_id":"f8e8f096f3f84417936ffe4a9ed5a518"},{"index":4,"title":"6515--Non-contact, quantitative corneal esthesiometers","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-30T20:53:03.379Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"f8e8f096f3f84417936ffe4a9ed5a518","solicitation_number":"36C24E26Q0082"}],"contacts":[{"name":"Matenoa Taufa","role":"primary","email":"matenoa.taufa@va.gov","phone":"412-822-3434","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"f8e8f096f3f84417936ffe4a9ed5a518","lineage_id":"f8e8f096f3f84417936ffe4a9ed5a518","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-27T02:31:11.846567081Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"57af067c9d6834d88be21aeebcca5f12b6717d3d2ecf06ff754656a1bfebb2d0","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-27T02:31:11.846567081Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"Summary: This is a Sources Sought notice and not a request for quotes. This request is solely for the purpose of conducting market research to enhance VHA s understanding of the market s offered products, services and capabilities. The Government will not pay any costs for responses submitted in response to this Sources Sought.Â \n\nThis Sources Sought notice provides an opportunity for respondents to submit their notice of ability, and their available products and services in response to the requirement described below. Vendors are invited to submit information relative to their potential of fulfilling the requirement below, in the form of a capability response that addresses the specific requirement identified in this Sources Sought. Â \n\nÂ The Veterans Health Administration (VHA) is seeking a vendor to provide two (2) Corneal Esthesiometer units, a commercially available non-contact, standardized, quantitative device capable of assessing corneal nerve function using controlled air pulses. The devices will enable non-invasive, quantitative assessment of corneal sensitivity in animal models to support the study s scientific goals. This Sources Sought is to facilitate the Contracting Officer s review of the market base, for acquisition planning, size determination, and procurement strategy.Â \n\nThe Department of Veterans Affairs, Columbia Health Care System, is in need ofÂ two (2) non-contact, quantitative corneal esthesiometers and shipment of required equipment (all components that make up this system).\n\nTechnical Specifications\nSalient characteristics of the non-contact, quantitative corneal esthesiometers. All specifications and conditions listed below shall be met in full to be considered. Minimum physical, functional, & performance characteristics:\nNon-contact, quantitative corneal esthesiometer units Technical Specifications: \nProvide true non-contact corneal sensitivity testing using precisely controlled air pulse stimuli, not mechanical filaments.\nDeliver quantitative, standardized multi-level stimulation validated for reproducible corneal nerve assessments.\nInclude an integrated Electronic Positioning System (EPS) consisting of a camera with infrared LED alignment to ensure consistent and correct testing distance on every measurement.\nBe fully portable and handheld, with optional slit lamp mounting capability.\nOperate as a stand-alone unit with no external computer, no software, and no network or data transfer interfaces.\nRequire no calibration and no routine maintenance, aside from normal cleaning per manufacturer instructions.\nProvide repeatable performance sufficient for preclinical research evaluating corneal nerve damage and response to therapeutic interventions.\nAll included accessories: battery, charging dock, manuals, and integrated EPS (Electronic Positioning System).\nDevices must be provided, new, fully functional, and covered under the manufacturer s two-year warranty.\nMust be an authorized distributor of the proposed system.\n4. Delivery:Â \nColumbia VAMC, \n800 Hospital Dr\nColumbia MO 65201\nUnited States\n\n5. Installation:Â \nÂ Installation is not required.Â \nÂ \n6. Information Technology:Â \nIT support requirements are not required for this equipment.Â \nÂ \n\nRESPONSE COMMITMENT Â \n\nÂ I. Response: Â \nÂ A. Capability statement and with general understanding of the industry and current knowledge and subcontract networks that would be used to support the requirement as identified herein. Provide small business information for your company.\nÂ B. Submittals furnished will not be returned to the sender. No debriefs will be conducted. Eligibility in participating in a future acquisition does not depend upon a response to this notice. Â \n\nÂ II. Timeline: Â \nA. This request will close on stated date within the Government Point of Entry (GPE). Â \n\nÂ Notes: Â \nThis Sources SoughtÂ is for planning purposes only to gain knowledge of potential qualified sources and their size classification (large business, small business, 8(a), SDVOSB, etc.), relative to NAICS code 334516. Responses to this sources soughtÂ will be used by the Government to make appropriate acquisition decisions.Â This notice is not a request for competitive proposals; however, any responsible source who believes it is capable of meeting the requirement and who is the Original Equipment Manufacturer (OEM), authorized dealer, authorized distributor or authorized reseller of all the items listed above, may submit a capability statement to the contracting office than no later than Tuesday, August 4, 2026, 16:00 PM EST. Interest/capability statements may be sent to Matenoa Taufa Matenoa.taufa@va.gov. No telephone responses will be accepted.Â","text":"Summary: This is a Sources Sought notice and not a request for quotes. This request is solely for the purpose of conducting market research to enhance VHA s understanding of the market s offered products, services and capabilities. The Government will not pay any costs for responses submitted in response to this Sources Sought.Â\n\nThis Sources Sought notice provides an opportunity for respondents to submit their notice of ability, and their available products and services in response to the requirement described below. Vendors are invited to submit information relative to their potential of fulfilling the requirement below, in the form of a capability response that addresses the specific requirement identified in this Sources Sought. Â\n\nÂ The Veterans Health Administration (VHA) is seeking a vendor to provide two (2) Corneal Esthesiometer units, a commercially available non-contact, standardized, quantitative device capable of assessing corneal nerve function using controlled air pulses. The devices will enable non-invasive, quantitative assessment of corneal sensitivity in animal models to support the study s scientific goals. This Sources Sought is to facilitate the Contracting Officer s review of the market base, for acquisition planning, size determination, and procurement strategy.Â\n\nThe Department of Veterans Affairs, Columbia Health Care System, is in need ofÂ two (2) non-contact, quantitative corneal esthesiometers and shipment of required equipment (all components that make up this system).\n\nTechnical Specifications\nSalient characteristics of the non-contact, quantitative corneal esthesiometers. All specifications and conditions listed below shall be met in full to be considered. Minimum physical, functional, & performance characteristics:\nNon-contact, quantitative corneal esthesiometer units Technical Specifications:\nProvide true non-contact corneal sensitivity testing using precisely controlled air pulse stimuli, not mechanical filaments.\nDeliver quantitative, standardized multi-level stimulation validated for reproducible corneal nerve assessments.\nInclude an integrated Electronic Positioning System (EPS) consisting of a camera with infrared LED alignment to ensure consistent and correct testing distance on every measurement.\nBe fully portable and handheld, with optional slit lamp mounting capability.\nOperate as a stand-alone unit with no external computer, no software, and no network or data transfer interfaces.\nRequire no calibration and no routine maintenance, aside from normal cleaning per manufacturer instructions.\nProvide repeatable performance sufficient for preclinical research evaluating corneal nerve damage and response to therapeutic interventions.\nAll included accessories: battery, charging dock, manuals, and integrated EPS (Electronic Positioning System).\nDevices must be provided, new, fully functional, and covered under the manufacturer s two-year warranty.\nMust be an authorized distributor of the proposed system.\n4. Delivery:Â\nColumbia VAMC,\n800 Hospital Dr\nColumbia MO 65201\nUnited States\n\n5. Installation:Â\nÂ Installation is not required.Â\nÂ\n6. Information Technology:Â\nIT support requirements are not required for this equipment.Â\nÂ\n\nRESPONSE COMMITMENT Â\n\nÂ I. Response: Â\nÂ A. Capability statement and with general understanding of the industry and current knowledge and subcontract networks that would be used to support the requirement as identified herein. Provide small business information for your company.\nÂ B. Submittals furnished will not be returned to the sender. No debriefs will be conducted. Eligibility in participating in a future acquisition does not depend upon a response to this notice. Â\n\nÂ II. Timeline: Â\nA. This request will close on stated date within the Government Point of Entry (GPE). Â\n\nÂ Notes: Â\nThis Sources SoughtÂ is for planning purposes only to gain knowledge of potential qualified sources and their size classification (large business, small business, 8(a), SDVOSB, etc.), relative to NAICS code 334516. Responses to this sources soughtÂ will be used by the Government to make appropriate acquisition decisions.Â This notice is not a request for competitive proposals; however, any responsible source who believes it is capable of meeting the requirement and who is the Original Equipment Manufacturer (OEM), authorized dealer, authorized distributor or authorized reseller of all the items listed above, may submit a capability statement to the contracting office than no later than Tuesday, August 4, 2026, 16:00 PM EST. Interest/capability statements may be sent to Matenoa Taufa Matenoa.taufa@va.gov. No telephone responses will be accepted.Â","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24E26Q0082","place_of_performance":{"zip":"65201","city":{"name":"Columbia,"},"state":{"name":"MO"},"street":"Veterans Health Administration Columbia VAMC,","street2":"800 Hospital Dr"},"product_service_code":"6515"},{"award":{"awardee":{}},"dates":{"posted":"2026-08-06","posted_at":"2026-08-06T21:48:53.376Z","created_at":"2026-08-06T21:48:51.149Z","modified_at":"2026-09-11T05:07:20.493Z","response_deadline":{"raw":"2026-08-12T16:00:00-04:00","utc":"2026-08-12T20:00:00Z","date":"2026-08-12","time":"16:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/cedb9b9d12054de9b0acba8ad48c5c69/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"6515--Corneal Esthesiometer Unit","agency":{"office":{"code":"36C24E","name":"RPO EAST (36C24E)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"15212","city":"PITTSBURGH","state":"PA","country":"USA"},"organization_id":"100183218","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-09-11","archive_type":"auto_custom"},"history":[{"index":6,"title":"6515--Corneal Esthesiometer Unit","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-06T21:48:53.376Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"cedb9b9d12054de9b0acba8ad48c5c69","solicitation_number":"36C24E26Q0082","related_opportunity_id":"f8e8f096f3f84417936ffe4a9ed5a518"},{"index":4,"title":"6515--Non-contact, quantitative corneal esthesiometers","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-30T20:53:03.379Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"f8e8f096f3f84417936ffe4a9ed5a518","solicitation_number":"36C24E26Q0082"}],"contacts":[{"name":"Matenoa Taufa","role":"primary","email":"matenoa.taufa@va.gov","phone":"412-822-3434","title":"Contracting Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"cedb9b9d12054de9b0acba8ad48c5c69","lineage_id":"f8e8f096f3f84417936ffe4a9ed5a518","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-26T02:08:51.734958559Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"8c355d95333a2ddd73a1510d8f66f5f6f8bff697c11af0d9abb13ffedf6dce89","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-26T02:08:51.734958559Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"Special Notice\n\nSpecial Notice\n\nPage 3 of 3\n\n\nSpecial Notice\n\nPage 1 of 3\nPre-Solicitation Notice for notice of intent to award a sole source contract. This is not a solicitation. The Department of Veterans Affairs intends to negotiate a sole source contract for a 3-month base period Brill Pharmaceuticals USA. The requirement is for two (2) Brill Corneal Esthesiometer V.2 units.\n\nSalient Characteristics:\nProvide true non-contact corneal sensitivity testing using precisely controlled air pulse stimuli, not mechanical filaments.\nDeliver quantitative, standardized multi-level stimulation validated for reproducible corneal nerve assessments.\nInclude an integrated Electronic Positioning System (EPS) consisting of a camera with infrared LED alignment to ensure consistent and correct testing distance on every measurement.\nBe fully portable and handheld, with optional slit lamp mounting capability.\nOperate as a stand-alone unit with no external computer, no software, and no network or data transfer interfaces.\nRequire no calibration and no routine maintenance, aside from normal cleaning per manufacturer instructions.\nProvide repeatable performance sufficient for preclinical research evaluating corneal nerve damage and response to therapeutic interventions.\nAll included accessories: battery, charging dock, manuals, and integrated EPS (Electronic Positioning System).\nDevices must be provided, new, fully functional, and covered under the manufacturer s two-year warranty.\nMust be an authorized distributor of the proposed system.\nBrill Pharmaceuticals USA Corp. is the exclusive manufacturer and distributor of Corneal Esthesiometer V.2 units, a commercially available non-contact, standardized, quantitative device capable of assessing corneal nerve function using controlled air pulses. The system shall allow research to provide precisely target and control PCO2 and PO2 in spontaneously breathing patients. \n\nThis procurement is being conducted IAW FAR 6.302-1, Only one responsible source and no other supplies will satisfy agency requirements and VHAPM Part 813.106-1(b), Other Than Full and Open Competition less than SAT for Open Market Items. This is because the Government asserts that Brill Pharmaceuticals USA Corp., is the only contractor that can produce these specific services required by the Research and Development Service at Columbia VA Medical Center.   \n\nInterested persons may contact the Contracting Specialist via email at Matenoa.taufa@va.gov regarding this procurement. The determination to conduct a competitive procurement based on responses to this notice is solely within the discretion of the Contracting Officer.","text":"Special Notice\n\nSpecial Notice\n\nPage 3 of 3\n\nSpecial Notice\n\nPage 1 of 3\nPre-Solicitation Notice for notice of intent to award a sole source contract. This is not a solicitation. The Department of Veterans Affairs intends to negotiate a sole source contract for a 3-month base period Brill Pharmaceuticals USA. The requirement is for two (2) Brill Corneal Esthesiometer V.2 units.\n\nSalient Characteristics:\nProvide true non-contact corneal sensitivity testing using precisely controlled air pulse stimuli, not mechanical filaments.\nDeliver quantitative, standardized multi-level stimulation validated for reproducible corneal nerve assessments.\nInclude an integrated Electronic Positioning System (EPS) consisting of a camera with infrared LED alignment to ensure consistent and correct testing distance on every measurement.\nBe fully portable and handheld, with optional slit lamp mounting capability.\nOperate as a stand-alone unit with no external computer, no software, and no network or data transfer interfaces.\nRequire no calibration and no routine maintenance, aside from normal cleaning per manufacturer instructions.\nProvide repeatable performance sufficient for preclinical research evaluating corneal nerve damage and response to therapeutic interventions.\nAll included accessories: battery, charging dock, manuals, and integrated EPS (Electronic Positioning System).\nDevices must be provided, new, fully functional, and covered under the manufacturer s two-year warranty.\nMust be an authorized distributor of the proposed system.\nBrill Pharmaceuticals USA Corp. is the exclusive manufacturer and distributor of Corneal Esthesiometer V.2 units, a commercially available non-contact, standardized, quantitative device capable of assessing corneal nerve function using controlled air pulses. The system shall allow research to provide precisely target and control PCO2 and PO2 in spontaneously breathing patients.\n\nThis procurement is being conducted IAW FAR 6.302-1, Only one responsible source and no other supplies will satisfy agency requirements and VHAPM Part 813.106-1(b), Other Than Full and Open Competition less than SAT for Open Market Items. This is because the Government asserts that Brill Pharmaceuticals USA Corp., is the only contractor that can produce these specific services required by the Research and Development Service at Columbia VA Medical Center.\n\nInterested persons may contact the Contracting Specialist via email at Matenoa.taufa@va.gov regarding this procurement. The determination to conduct a competitive procurement based on responses to this notice is solely within the discretion of the Contracting Officer.","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"36C24E26Q0082","product_service_code":"6515"}],"due_at":"2026-08-04T20:00:00Z","due_date":"2026-08-04","closes_at":"2026-08-04T20:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C24E","office_name":"RPO EAST (36C24E)","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":null,"state_evidence":"Product purchase (PSC 6515)","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-26T02:13:41.485025Z","principal_notice_id":"cedb9b9d12054de9b0acba8ad48c5c69","description":{"text":"Special Notice\n\nSpecial Notice\n\nPage 3 of 3\n\nSpecial Notice\n\nPage 1 of 3\nPre-Solicitation Notice for notice of intent to award a sole source contract. This is not a solicitation. The Department of Veterans Affairs intends to negotiate a sole source contract for a 3-month base period Brill Pharmaceuticals USA. The requirement is for two (2) Brill Corneal Esthesiometer V.2 units.\n\nSalient Characteristics:\nProvide true non-contact corneal sensitivity testing using precisely controlled air pulse stimuli, not mechanical filaments.\nDeliver quantitative, standardized multi-level stimulation validated for reproducible corneal nerve assessments.\nInclude an integrated Electronic Positioning System (EPS) consisting of a camera with infrared LED alignment to ensure consistent and correct testing distance on every measurement.\nBe fully portable and handheld, with optional slit lamp mounting capability.\nOperate as a stand-alone unit with no external computer, no software, and no network or data transfer interfaces.\nRequire no calibration and no routine maintenance, aside from normal cleaning per manufacturer instructions.\nProvide repeatable performance sufficient for preclinical research evaluating corneal nerve damage and response to therapeutic interventions.\nAll included accessories: battery, charging dock, manuals, and integrated EPS (Electronic Positioning System).\nDevices must be provided, new, fully functional, and covered under the manufacturer s two-year warranty.\nMust be an authorized distributor of the proposed system.\nBrill Pharmaceuticals USA Corp. is the exclusive manufacturer and distributor of Corneal Esthesiometer V.2 units, a commercially available non-contact, standardized, quantitative device capable of assessing corneal nerve function using controlled air pulses. The system shall allow research to provide precisely target and control PCO2 and PO2 in spontaneously breathing patients.\n\nThis procurement is being conducted IAW FAR 6.302-1, Only one responsible source and no other supplies will satisfy agency requirements and VHAPM Part 813.106-1(b), Other Than Full and Open Competition less than SAT for Open Market Items. This is because the Government asserts that Brill Pharmaceuticals USA Corp., is the only contractor that can produce these specific services required by the Research and Development Service at Columbia VA Medical Center.\n\nInterested persons may contact the Contracting Specialist via email at Matenoa.taufa@va.gov regarding this procurement. The determination to conduct a competitive procurement based on responses to this notice is solely within the discretion of the Contracting Officer.","html":"Special Notice\n\nSpecial Notice\n\nPage 3 of 3\n\n\nSpecial Notice\n\nPage 1 of 3\nPre-Solicitation Notice for notice of intent to award a sole source contract. This is not a solicitation. The Department of Veterans Affairs intends to negotiate a sole source contract for a 3-month base period Brill Pharmaceuticals USA. The requirement is for two (2) Brill Corneal Esthesiometer V.2 units.\n\nSalient Characteristics:\nProvide true non-contact corneal sensitivity testing using precisely controlled air pulse stimuli, not mechanical filaments.\nDeliver quantitative, standardized multi-level stimulation validated for reproducible corneal nerve assessments.\nInclude an integrated Electronic Positioning System (EPS) consisting of a camera with infrared LED alignment to ensure consistent and correct testing distance on every measurement.\nBe fully portable and handheld, with optional slit lamp mounting capability.\nOperate as a stand-alone unit with no external computer, no software, and no network or data transfer interfaces.\nRequire no calibration and no routine maintenance, aside from normal cleaning per manufacturer instructions.\nProvide repeatable performance sufficient for preclinical research evaluating corneal nerve damage and response to therapeutic interventions.\nAll included accessories: battery, charging dock, manuals, and integrated EPS (Electronic Positioning System).\nDevices must be provided, new, fully functional, and covered under the manufacturer s two-year warranty.\nMust be an authorized distributor of the proposed system.\nBrill Pharmaceuticals USA Corp. is the exclusive manufacturer and distributor of Corneal Esthesiometer V.2 units, a commercially available non-contact, standardized, quantitative device capable of assessing corneal nerve function using controlled air pulses. The system shall allow research to provide precisely target and control PCO2 and PO2 in spontaneously breathing patients. \n\nThis procurement is being conducted IAW FAR 6.302-1, Only one responsible source and no other supplies will satisfy agency requirements and VHAPM Part 813.106-1(b), Other Than Full and Open Competition less than SAT for Open Market Items. This is because the Government asserts that Brill Pharmaceuticals USA Corp., is the only contractor that can produce these specific services required by the Research and Development Service at Columbia VA Medical Center.   \n\nInterested persons may contact the Contracting Specialist via email at Matenoa.taufa@va.gov regarding this procurement. The determination to conduct a competitive procurement based on responses to this notice is solely within the discretion of the Contracting Officer.","origin":"detail"},"contacts":[{"name":"Matenoa Taufa","role":"primary","email":"matenoa.taufa@va.gov","phone":"412-822-3434","title":"Contracting Specialist"}],"place_of_performance":null,"office_address":{"zip":"15212","city":"PITTSBURGH","state":"PA","country":"USA"},"naics_codes":["334516"],"award":{"awardee":{}},"attachments":[{"resource_id":"f0af5e09d6f44d08a4efaed9f046ada5","name":"36C24E26Q0082_1.docx","kind":"file","mime_type":".docx","size_bytes":27987,"posted_at":"2026-07-30T20:53:03.379Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/f0af5e09d6f44d08a4efaed9f046ada5/download","mirrored":false},{"resource_id":"1880ce2b502d4473b2693154838f14a8","name":"36C24E26Q0082_2.docx","kind":"file","mime_type":".docx","size_bytes":30379,"posted_at":"2026-08-06T21:48:53.376Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/1880ce2b502d4473b2693154838f14a8/download","mirrored":false}],"awards":[],"related":[],"similar_open":[{"key":"68HERL27Q0018","latest_notice_id":"95332551fa5b4851bc7f5a28a560675c","title":"66--RFI & Sources Sought for GC/Q-TOF MS Lab Equipment","solicitation_number":"68HERL27Q0018","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-25T18:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-068","dept_name":"ENVIRONMENTAL PROTECTION AGENCY","sub_key":"s-6800","sub_name":"ENVIRONMENTAL PROTECTION AGENCY","office_key":"o-68HE0M","office_name":"LAB - ANN ARBOR, MI - CO OFFICE","naics":"334516","psc":"6640","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6640)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"89243327QEX000002","latest_notice_id":"2507c3f1a48c4f2bad80f7ae604ba05a","title":"66--Brand Name or Equal Teledyne Instruments Liquid Sy","solicitation_number":"89243327QEX000002","notice_type":"o","first_type":"o","first_posted":"2026-11-05","last_posted":"2026-11-19","notices":3,"due_at":"2026-11-25T22:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-892433","office_name":"NATIONAL ENERGY TECHNOLOGY LABORATORY","naics":"334516","psc":"6640","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6640)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"89243327QEX000003","latest_notice_id":"1dee4e8cc79a4245a52ca82c963125bd","title":"Brand Name or Equal Across International 2R50f.110","solicitation_number":"89243327QEX000003","notice_type":"o","first_type":"o","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":"2026-11-25T22:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-892433","office_name":"NATIONAL ENERGY TECHNOLOGY LABORATORY","naics":"334516","psc":"6640","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6640)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"}],"similar_open_total":60,"indexable":false}