{"canonical":"https://sealedbidder.com/opportunities/36c24e25q0042","key":"36C24E25Q0042","url":"https://sealedbidder.com/opportunities/36c24e25q0042","title":"J065--Tech Support Package-PM BD FACS Symphony A3 flow cytometer","solicitation_number":"36C24E25Q0042","notice_type":"s","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-04-24T15:59:00Z","first_posted":"2025-04-17","last_posted":"2025-04-17","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"RPO EAST (36C24E)","naics":"811310","psc":"J065","set_aside":null,"place_state":"MI","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"26161","place_county_name":"Washtenaw County","place_city":"2603000","place_city_name":"Ann Arbor","winner":"BECTON, DICKINSON AND COMPANY","award_amount":null,"publications":[{"notice_id":"8e30527e12254c7182d4bf072d467911","title":"J065--Tech Support Package-PM BD FACS Symphony A3 flow cytometer","solicitation_number":"36C24E25Q0042","notice_type":"s","base_type":"s","posted":"2025-04-17","posted_at":"2025-04-17T18:13:02.242Z","due_at":"2025-04-24T15:59:00Z","due_date":"2025-04-24","cancelled":false,"archived":true,"archive_date":"2025-06-23","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/8e30527e12254c7182d4bf072d467911/view","enriched":true,"history":[{"index":3,"title":"J065--Tech Support Package-PM BD FACS Symphony A3 flow cytometer","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-17T18:13:02.242Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"8e30527e12254c7182d4bf072d467911","solicitation_number":"36C24E25Q0042"}]}],"latest_notice_id":"8e30527e12254c7182d4bf072d467911","first_type":"s","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-04-17","posted_at":"2025-04-17T18:13:02.242Z","created_at":"2025-04-17T18:13:00.075Z","modified_at":"2025-06-24T03:55:51.722Z","response_deadline":{"raw":"2025-04-24T11:59:00-04:00","utc":"2025-04-24T15:59:00Z","date":"2025-04-24","time":"11:59:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/8e30527e12254c7182d4bf072d467911/view"},"naics":{"codes":["811310"],"primary":"811310"},"title":"J065--Tech Support Package-PM BD FACS Symphony A3 flow cytometer","agency":{"office":{"code":"36C24E","name":"RPO EAST (36C24E)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"15212","city":"PITTSBURGH","state":"PA","country":"USA"},"organization_id":"100183218","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-06-23","archive_type":"auto_custom"},"history":[{"index":3,"title":"J065--Tech Support Package-PM BD FACS Symphony A3 flow cytometer","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-17T18:13:02.242Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"8e30527e12254c7182d4bf072d467911","solicitation_number":"36C24E25Q0042"}],"contacts":[{"name":"Mae McGarry","role":"primary","email":"mae.mcgarry@va.gov","phone":"Calls will not be accepted.","title":"Contract Specialist"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"8e30527e12254c7182d4bf072d467911","lineage_id":"8e30527e12254c7182d4bf072d467911","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-17T09:44:37.104647008Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"a68e0ca608311cbfde585da783d32be71686d2852e14f10ab60864d727944caf","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-17T09:44:37.104647008Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Regional Procurement Office (RPO) - East intends to negotiate on a sole source basis with BECTON, DICKINSON AND COMPANY, 1, Becton Drive, Franklin Lakes, New Jersey 07417-1880, to purchase Tech-Support preventative maintenance for BD FACS Symphony A3 flow cytometer. For the VA Ann Arbor Health Care System. Becton Dickinson and Company is the only capable entity to provide services for its proprietary equipment. \nStatement of Work\nGeneral Objectives and Requirements\nTitle: Service Contract for BD FACS Symphony A3\nAuthority for the project:  Christine Basmajian, PhD, Deputy Associate Chief of Staff, Research Service, VA Ann Arbor Healthcare System\nPurpose of the project: The purpose of this project is to obtain a service contract for a VA-owned piece of equipment, called the BD FACS Symphony A3 Cell Analyzer, which we will refer to as a  flow cytometer .  The service contract would cover both scheduled maintenance visits and also cover repair costs and technical support, all of which are needed to keep the flow cytometer in operating condition.\nBackground: The flow cytometer was purchased in April 2023 by the VA Ann Arbor Healthcare System.  The flow cytometer is central to the research needs of multiple investigators with VA-funded research projects, currently including Drs. Basmajian Curtis, Ganguly, Deng, Keshamouni, Olszewski, Goughenour, and Osterholzer.  The VA-funded projects supported by the flow cytometer include topics relevant to Veteran health, including chronic obstructive pulmonary disease (COPD), post-deployment health, particularly centered around toxic airborne exposures, host responses to pathogens, including COVID-19, cancer, and others. The flow cytometer is used on a daily basis, frequently for many hours during the day.   The initial purchase came with a 2-year warranty which included bi-annual preventative maintenance visits and service visits plus any necessary repairs.  A service contract is important to keep the flow cytometer operating at peak performance and to minimize any disruptions or downtimes caused by technical issues or equipment malfunction. \nScope and Methodology:  The Service Contract needs the following:\n-Two preventive maintenance visits per twelve-month period:  These visits must be performed by a qualified technician.  The technician must arrange the visit in advance with a designated point of contact to ensure that the flow cytometer will not be in use by research staff.  Travel expenses and parts needed for the visit must be included in the contract.  The technician will inspect the flow cytometer electronics, lasers, FACS Flow supply system, and other parts to ensure optimal performance.  Any performance issues must be remedied.  \n-Two preventive maintenance kits must be provided during the twelve-month period:  These kits are used by the technician when conducing the preventive maintenance visit.  They are also available for laboratory staff when minor fixes are needed.  Examples include replacing o-ring gaskets, or de-clogging the sample port.  \n-Technical support over the phone: If VA research staff identify issues with the flow cytometer performance, they must be able to obtain technical support by telephone.  The technical support staff should be able to talk the research staff member through potential solutions or fixes to the problem.  \n-On-site service:  If technical support over the phone is not able to adequately address the issue that the research staff are experiencing, a qualified technician must be provided to perform on-site service.  On-site service should be provided Monday through Friday (excluding holidays).  Travel expenses (Monday   Friday, excluding holidays) and parts needed for the visit must be included in the contract.  It is important that emergency on-site service visits can take place within a 48-hour (Monday through Friday, excluding holidays) turn-around time to minimize disruption and down-time which could otherwise result in the loss of experiments.\n\nTasks and Associated Deliverables\nDescription of tasks and associated deliverables: The service contract must be able to support the routing maintenance, trouble-shooting, and repair of the following instrumentation and components:\n\nComponents:\nSub-components\nNet PRICE\nFACSSymphony A3\n\n\nLaser Coherent OBIS 488-100 LS SORP\n\n\nSSC Detector Decagon with specific detectors:\nBB515 Detector (505LP; 515/20)\n\n\nBB630 Detector (600 LP; 610/20)\n\n\nBB700 Detector (690 LP; 710/750)\n\n\nBB790 Detector (770 LP; 780/60)\n\nLaser OBIS 637-140 LX SORP\n\n\nDetector Decagon w/o SSC with specific detectors:\nAPC Detector (650LP; 670/30)\n\n\nAlexa 700 Detector (690 LP; 710/750)\n\n\nAPC-Cy7 Detector (750 LP; 780/60)\n\nLaser Violet Coherent OBIS 405-100 LX\n\n\nDetector Decagon w/o SSC with specific detectors:\nBV421 Detector (410 LP; 431/28)\n\n\nBV480 Detector (450 LP; 470/14)\n\n\nBV605 Detector (600 LP; 610/20)\n\n\nBV650 Detector (635 LP; 670/30)\n\n\nBV711 Detector (690 LP; 710/50)\n\n\nBV786 Detector (750 LP; 780/60)\n\nLaser System UV-G4 355-20 W/BE SORP\n\n\n\nUV Detector Decagon w/o SSC with specific detectors:\nBUV396 Detector (378/29)\n\n\nBUV496 Detector (450LP: 515/30)\n\n\nBUV563 Detector (550LP: 586/15)\n\n\nBUV661 Detector (635 LP: 670/30\n\n\nBUV737 Detector (690 LP; 740/35)\n\n\nBUV805 Detector (770 LP; 820/60)\n\nLaser Coherent OBIS 561-100 LS SORP\n\n\nDetector Decagon w/o SSC with specific detectors:\nPE with 561 Detector (570 LP: 586/15)\n\n\nPE CF594 Detector (600 LP: 610/20)\n\n\nPE Cy5 Detector (650 LP: 670/30)\n\n\nPE Cy7 Detector (750 LP: 780/60)\n\nFACSflow Supply System\n\n\nX-Optic 450/50 (410 LP; 450/50)\n\n\nX-Optic 515/30 (450 LP: 515/30)\n\n\nCoherent connection with integration kit\n\n\nFACS Diva software\n\n\n\n\n\n\nTasks and deliverables include the following:\n-Preventive maintenance visits by qualified personnel (two visits in 12-month period)\n-Preventive maintenance kits (two kits in 12-month period)\n-Unlimited technical support by phone\n-Unlimited on-site visits by qualified personnel (Monday-Friday, excluding holidays) if problems are not resolved by phone support\n-Any parts, labor, or repairs needed as determined by the qualified personnel to ensure the flow cytometer is operating at peak performance\n\n\nReporting requirement:  The results of the preventive maintenance visits and all on-site visits will be provided by e-mail to the designated VA point-of-contact.  Plans for on-site visits will be communicated with the point-of-contact.  Verbal communication will also be used to provide updates regarding any issues with the flow cytometer and should include the plan of action to repair the flow cytometer, any parts that need to be ordered, and the anticipated time by which the repairs should be complete.  \n\n\n\nThis notice of intent is not a request for competitive proposals. Any responsible sources who wish to identify their interest and capability to provide this equipment or equipment that is compatible must notify this Contract Specialist at mae.mcgarry@va.gov NLT Thursday, April 24th, 2025 by 11:59 AM EST. Telephone responses will not be accepted. Upon receipt of the interested parties' notification, the Contract Specialist will determine whether to conduct a competitive procurement or proceed with sole source negotiations.","text":"Regional Procurement Office (RPO) - East intends to negotiate on a sole source basis with BECTON, DICKINSON AND COMPANY, 1, Becton Drive, Franklin Lakes, New Jersey 07417-1880, to purchase Tech-Support preventative maintenance for BD FACS Symphony A3 flow cytometer. For the VA Ann Arbor Health Care System. Becton Dickinson and Company is the only capable entity to provide services for its proprietary equipment.\nStatement of Work\nGeneral Objectives and Requirements\nTitle: Service Contract for BD FACS Symphony A3\nAuthority for the project: Christine Basmajian, PhD, Deputy Associate Chief of Staff, Research Service, VA Ann Arbor Healthcare System\nPurpose of the project: The purpose of this project is to obtain a service contract for a VA-owned piece of equipment, called the BD FACS Symphony A3 Cell Analyzer, which we will refer to as a flow cytometer . The service contract would cover both scheduled maintenance visits and also cover repair costs and technical support, all of which are needed to keep the flow cytometer in operating condition.\nBackground: The flow cytometer was purchased in April 2023 by the VA Ann Arbor Healthcare System. The flow cytometer is central to the research needs of multiple investigators with VA-funded research projects, currently including Drs. Basmajian Curtis, Ganguly, Deng, Keshamouni, Olszewski, Goughenour, and Osterholzer. The VA-funded projects supported by the flow cytometer include topics relevant to Veteran health, including chronic obstructive pulmonary disease (COPD), post-deployment health, particularly centered around toxic airborne exposures, host responses to pathogens, including COVID-19, cancer, and others. The flow cytometer is used on a daily basis, frequently for many hours during the day. The initial purchase came with a 2-year warranty which included bi-annual preventative maintenance visits and service visits plus any necessary repairs. A service contract is important to keep the flow cytometer operating at peak performance and to minimize any disruptions or downtimes caused by technical issues or equipment malfunction.\nScope and Methodology: The Service Contract needs the following:\n-Two preventive maintenance visits per twelve-month period: These visits must be performed by a qualified technician. The technician must arrange the visit in advance with a designated point of contact to ensure that the flow cytometer will not be in use by research staff. Travel expenses and parts needed for the visit must be included in the contract. The technician will inspect the flow cytometer electronics, lasers, FACS Flow supply system, and other parts to ensure optimal performance. Any performance issues must be remedied.\n-Two preventive maintenance kits must be provided during the twelve-month period: These kits are used by the technician when conducing the preventive maintenance visit. They are also available for laboratory staff when minor fixes are needed. Examples include replacing o-ring gaskets, or de-clogging the sample port.\n-Technical support over the phone: If VA research staff identify issues with the flow cytometer performance, they must be able to obtain technical support by telephone. The technical support staff should be able to talk the research staff member through potential solutions or fixes to the problem.\n-On-site service: If technical support over the phone is not able to adequately address the issue that the research staff are experiencing, a qualified technician must be provided to perform on-site service. On-site service should be provided Monday through Friday (excluding holidays). Travel expenses (Monday Friday, excluding holidays) and parts needed for the visit must be included in the contract. It is important that emergency on-site service visits can take place within a 48-hour (Monday through Friday, excluding holidays) turn-around time to minimize disruption and down-time which could otherwise result in the loss of experiments.\n\nTasks and Associated Deliverables\nDescription of tasks and associated deliverables: The service contract must be able to support the routing maintenance, trouble-shooting, and repair of the following instrumentation and components:\n\nComponents:\nSub-components\nNet PRICE\nFACSSymphony A3\n\nLaser Coherent OBIS 488-100 LS SORP\n\nSSC Detector Decagon with specific detectors:\nBB515 Detector (505LP; 515/20)\n\nBB630 Detector (600 LP; 610/20)\n\nBB700 Detector (690 LP; 710/750)\n\nBB790 Detector (770 LP; 780/60)\n\nLaser OBIS 637-140 LX SORP\n\nDetector Decagon w/o SSC with specific detectors:\nAPC Detector (650LP; 670/30)\n\nAlexa 700 Detector (690 LP; 710/750)\n\nAPC-Cy7 Detector (750 LP; 780/60)\n\nLaser Violet Coherent OBIS 405-100 LX\n\nDetector Decagon w/o SSC with specific detectors:\nBV421 Detector (410 LP; 431/28)\n\nBV480 Detector (450 LP; 470/14)\n\nBV605 Detector (600 LP; 610/20)\n\nBV650 Detector (635 LP; 670/30)\n\nBV711 Detector (690 LP; 710/50)\n\nBV786 Detector (750 LP; 780/60)\n\nLaser System UV-G4 355-20 W/BE SORP\n\nUV Detector Decagon w/o SSC with specific detectors:\nBUV396 Detector (378/29)\n\nBUV496 Detector (450LP: 515/30)\n\nBUV563 Detector (550LP: 586/15)\n\nBUV661 Detector (635 LP: 670/30\n\nBUV737 Detector (690 LP; 740/35)\n\nBUV805 Detector (770 LP; 820/60)\n\nLaser Coherent OBIS 561-100 LS SORP\n\nDetector Decagon w/o SSC with specific detectors:\nPE with 561 Detector (570 LP: 586/15)\n\nPE CF594 Detector (600 LP: 610/20)\n\nPE Cy5 Detector (650 LP: 670/30)\n\nPE Cy7 Detector (750 LP: 780/60)\n\nFACSflow Supply System\n\nX-Optic 450/50 (410 LP; 450/50)\n\nX-Optic 515/30 (450 LP: 515/30)\n\nCoherent connection with integration kit\n\nFACS Diva software\n\nTasks and deliverables include the following:\n-Preventive maintenance visits by qualified personnel (two visits in 12-month period)\n-Preventive maintenance kits (two kits in 12-month period)\n-Unlimited technical support by phone\n-Unlimited on-site visits by qualified personnel (Monday-Friday, excluding holidays) if problems are not resolved by phone support\n-Any parts, labor, or repairs needed as determined by the qualified personnel to ensure the flow cytometer is operating at peak performance\n\nReporting requirement: The results of the preventive maintenance visits and all on-site visits will be provided by e-mail to the designated VA point-of-contact. Plans for on-site visits will be communicated with the point-of-contact. Verbal communication will also be used to provide updates regarding any issues with the flow cytometer and should include the plan of action to repair the flow cytometer, any parts that need to be ordered, and the anticipated time by which the repairs should be complete.\n\nThis notice of intent is not a request for competitive proposals. Any responsible sources who wish to identify their interest and capability to provide this equipment or equipment that is compatible must notify this Contract Specialist at mae.mcgarry@va.gov NLT Thursday, April 24th, 2025 by 11:59 AM EST. Telephone responses will not be accepted. Upon receipt of the interested parties' notification, the Contract Specialist will determine whether to conduct a competitive procurement or proceed with sole source negotiations.","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"36C24E25Q0042","product_service_code":"J065"}],"due_at":"2025-04-24T15:59:00Z","due_date":"2025-04-24","closes_at":"2025-04-24T15:59:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C24E","office_name":"RPO EAST (36C24E)","state":"MI","county":"26161","county_name":"Washtenaw County","city":"2603000","city_name":"Ann Arbor","country":null,"state_source":null,"state_evidence":null,"site_key":null,"winner_key":"MM5ZHL8SRFY5","amount":null,"linked_awards":1,"cancelled":false,"archived":true,"updated_at":"2026-11-17T10:25:07.249564Z","principal_notice_id":"8e30527e12254c7182d4bf072d467911","description":{"text":"Regional Procurement Office (RPO) - East intends to negotiate on a sole source basis with BECTON, DICKINSON AND COMPANY, 1, Becton Drive, Franklin Lakes, New Jersey 07417-1880, to purchase Tech-Support preventative maintenance for BD FACS Symphony A3 flow cytometer. For the VA Ann Arbor Health Care System. Becton Dickinson and Company is the only capable entity to provide services for its proprietary equipment.\nStatement of Work\nGeneral Objectives and Requirements\nTitle: Service Contract for BD FACS Symphony A3\nAuthority for the project: Christine Basmajian, PhD, Deputy Associate Chief of Staff, Research Service, VA Ann Arbor Healthcare System\nPurpose of the project: The purpose of this project is to obtain a service contract for a VA-owned piece of equipment, called the BD FACS Symphony A3 Cell Analyzer, which we will refer to as a flow cytometer . The service contract would cover both scheduled maintenance visits and also cover repair costs and technical support, all of which are needed to keep the flow cytometer in operating condition.\nBackground: The flow cytometer was purchased in April 2023 by the VA Ann Arbor Healthcare System. The flow cytometer is central to the research needs of multiple investigators with VA-funded research projects, currently including Drs. Basmajian Curtis, Ganguly, Deng, Keshamouni, Olszewski, Goughenour, and Osterholzer. The VA-funded projects supported by the flow cytometer include topics relevant to Veteran health, including chronic obstructive pulmonary disease (COPD), post-deployment health, particularly centered around toxic airborne exposures, host responses to pathogens, including COVID-19, cancer, and others. The flow cytometer is used on a daily basis, frequently for many hours during the day. The initial purchase came with a 2-year warranty which included bi-annual preventative maintenance visits and service visits plus any necessary repairs. A service contract is important to keep the flow cytometer operating at peak performance and to minimize any disruptions or downtimes caused by technical issues or equipment malfunction.\nScope and Methodology: The Service Contract needs the following:\n-Two preventive maintenance visits per twelve-month period: These visits must be performed by a qualified technician. The technician must arrange the visit in advance with a designated point of contact to ensure that the flow cytometer will not be in use by research staff. Travel expenses and parts needed for the visit must be included in the contract. The technician will inspect the flow cytometer electronics, lasers, FACS Flow supply system, and other parts to ensure optimal performance. Any performance issues must be remedied.\n-Two preventive maintenance kits must be provided during the twelve-month period: These kits are used by the technician when conducing the preventive maintenance visit. They are also available for laboratory staff when minor fixes are needed. Examples include replacing o-ring gaskets, or de-clogging the sample port.\n-Technical support over the phone: If VA research staff identify issues with the flow cytometer performance, they must be able to obtain technical support by telephone. The technical support staff should be able to talk the research staff member through potential solutions or fixes to the problem.\n-On-site service: If technical support over the phone is not able to adequately address the issue that the research staff are experiencing, a qualified technician must be provided to perform on-site service. On-site service should be provided Monday through Friday (excluding holidays). Travel expenses (Monday Friday, excluding holidays) and parts needed for the visit must be included in the contract. It is important that emergency on-site service visits can take place within a 48-hour (Monday through Friday, excluding holidays) turn-around time to minimize disruption and down-time which could otherwise result in the loss of experiments.\n\nTasks and Associated Deliverables\nDescription of tasks and associated deliverables: The service contract must be able to support the routing maintenance, trouble-shooting, and repair of the following instrumentation and components:\n\nComponents:\nSub-components\nNet PRICE\nFACSSymphony A3\n\nLaser Coherent OBIS 488-100 LS SORP\n\nSSC Detector Decagon with specific detectors:\nBB515 Detector (505LP; 515/20)\n\nBB630 Detector (600 LP; 610/20)\n\nBB700 Detector (690 LP; 710/750)\n\nBB790 Detector (770 LP; 780/60)\n\nLaser OBIS 637-140 LX SORP\n\nDetector Decagon w/o SSC with specific detectors:\nAPC Detector (650LP; 670/30)\n\nAlexa 700 Detector (690 LP; 710/750)\n\nAPC-Cy7 Detector (750 LP; 780/60)\n\nLaser Violet Coherent OBIS 405-100 LX\n\nDetector Decagon w/o SSC with specific detectors:\nBV421 Detector (410 LP; 431/28)\n\nBV480 Detector (450 LP; 470/14)\n\nBV605 Detector (600 LP; 610/20)\n\nBV650 Detector (635 LP; 670/30)\n\nBV711 Detector (690 LP; 710/50)\n\nBV786 Detector (750 LP; 780/60)\n\nLaser System UV-G4 355-20 W/BE SORP\n\nUV Detector Decagon w/o SSC with specific detectors:\nBUV396 Detector (378/29)\n\nBUV496 Detector (450LP: 515/30)\n\nBUV563 Detector (550LP: 586/15)\n\nBUV661 Detector (635 LP: 670/30\n\nBUV737 Detector (690 LP; 740/35)\n\nBUV805 Detector (770 LP; 820/60)\n\nLaser Coherent OBIS 561-100 LS SORP\n\nDetector Decagon w/o SSC with specific detectors:\nPE with 561 Detector (570 LP: 586/15)\n\nPE CF594 Detector (600 LP: 610/20)\n\nPE Cy5 Detector (650 LP: 670/30)\n\nPE Cy7 Detector (750 LP: 780/60)\n\nFACSflow Supply System\n\nX-Optic 450/50 (410 LP; 450/50)\n\nX-Optic 515/30 (450 LP: 515/30)\n\nCoherent connection with integration kit\n\nFACS Diva software\n\nTasks and deliverables include the following:\n-Preventive maintenance visits by qualified personnel (two visits in 12-month period)\n-Preventive maintenance kits (two kits in 12-month period)\n-Unlimited technical support by phone\n-Unlimited on-site visits by qualified personnel (Monday-Friday, excluding holidays) if problems are not resolved by phone support\n-Any parts, labor, or repairs needed as determined by the qualified personnel to ensure the flow cytometer is operating at peak performance\n\nReporting requirement: The results of the preventive maintenance visits and all on-site visits will be provided by e-mail to the designated VA point-of-contact. Plans for on-site visits will be communicated with the point-of-contact. Verbal communication will also be used to provide updates regarding any issues with the flow cytometer and should include the plan of action to repair the flow cytometer, any parts that need to be ordered, and the anticipated time by which the repairs should be complete.\n\nThis notice of intent is not a request for competitive proposals. Any responsible sources who wish to identify their interest and capability to provide this equipment or equipment that is compatible must notify this Contract Specialist at mae.mcgarry@va.gov NLT Thursday, April 24th, 2025 by 11:59 AM EST. Telephone responses will not be accepted. Upon receipt of the interested parties' notification, the Contract Specialist will determine whether to conduct a competitive procurement or proceed with sole source negotiations.","html":"Regional Procurement Office (RPO) - East intends to negotiate on a sole source basis with BECTON, DICKINSON AND COMPANY, 1, Becton Drive, Franklin Lakes, New Jersey 07417-1880, to purchase Tech-Support preventative maintenance for BD FACS Symphony A3 flow cytometer. For the VA Ann Arbor Health Care System. Becton Dickinson and Company is the only capable entity to provide services for its proprietary equipment. \nStatement of Work\nGeneral Objectives and Requirements\nTitle: Service Contract for BD FACS Symphony A3\nAuthority for the project:  Christine Basmajian, PhD, Deputy Associate Chief of Staff, Research Service, VA Ann Arbor Healthcare System\nPurpose of the project: The purpose of this project is to obtain a service contract for a VA-owned piece of equipment, called the BD FACS Symphony A3 Cell Analyzer, which we will refer to as a  flow cytometer .  The service contract would cover both scheduled maintenance visits and also cover repair costs and technical support, all of which are needed to keep the flow cytometer in operating condition.\nBackground: The flow cytometer was purchased in April 2023 by the VA Ann Arbor Healthcare System.  The flow cytometer is central to the research needs of multiple investigators with VA-funded research projects, currently including Drs. Basmajian Curtis, Ganguly, Deng, Keshamouni, Olszewski, Goughenour, and Osterholzer.  The VA-funded projects supported by the flow cytometer include topics relevant to Veteran health, including chronic obstructive pulmonary disease (COPD), post-deployment health, particularly centered around toxic airborne exposures, host responses to pathogens, including COVID-19, cancer, and others. The flow cytometer is used on a daily basis, frequently for many hours during the day.   The initial purchase came with a 2-year warranty which included bi-annual preventative maintenance visits and service visits plus any necessary repairs.  A service contract is important to keep the flow cytometer operating at peak performance and to minimize any disruptions or downtimes caused by technical issues or equipment malfunction. \nScope and Methodology:  The Service Contract needs the following:\n-Two preventive maintenance visits per twelve-month period:  These visits must be performed by a qualified technician.  The technician must arrange the visit in advance with a designated point of contact to ensure that the flow cytometer will not be in use by research staff.  Travel expenses and parts needed for the visit must be included in the contract.  The technician will inspect the flow cytometer electronics, lasers, FACS Flow supply system, and other parts to ensure optimal performance.  Any performance issues must be remedied.  \n-Two preventive maintenance kits must be provided during the twelve-month period:  These kits are used by the technician when conducing the preventive maintenance visit.  They are also available for laboratory staff when minor fixes are needed.  Examples include replacing o-ring gaskets, or de-clogging the sample port.  \n-Technical support over the phone: If VA research staff identify issues with the flow cytometer performance, they must be able to obtain technical support by telephone.  The technical support staff should be able to talk the research staff member through potential solutions or fixes to the problem.  \n-On-site service:  If technical support over the phone is not able to adequately address the issue that the research staff are experiencing, a qualified technician must be provided to perform on-site service.  On-site service should be provided Monday through Friday (excluding holidays).  Travel expenses (Monday   Friday, excluding holidays) and parts needed for the visit must be included in the contract.  It is important that emergency on-site service visits can take place within a 48-hour (Monday through Friday, excluding holidays) turn-around time to minimize disruption and down-time which could otherwise result in the loss of experiments.\n\nTasks and Associated Deliverables\nDescription of tasks and associated deliverables: The service contract must be able to support the routing maintenance, trouble-shooting, and repair of the following instrumentation and components:\n\nComponents:\nSub-components\nNet PRICE\nFACSSymphony A3\n\n\nLaser Coherent OBIS 488-100 LS SORP\n\n\nSSC Detector Decagon with specific detectors:\nBB515 Detector (505LP; 515/20)\n\n\nBB630 Detector (600 LP; 610/20)\n\n\nBB700 Detector (690 LP; 710/750)\n\n\nBB790 Detector (770 LP; 780/60)\n\nLaser OBIS 637-140 LX SORP\n\n\nDetector Decagon w/o SSC with specific detectors:\nAPC Detector (650LP; 670/30)\n\n\nAlexa 700 Detector (690 LP; 710/750)\n\n\nAPC-Cy7 Detector (750 LP; 780/60)\n\nLaser Violet Coherent OBIS 405-100 LX\n\n\nDetector Decagon w/o SSC with specific detectors:\nBV421 Detector (410 LP; 431/28)\n\n\nBV480 Detector (450 LP; 470/14)\n\n\nBV605 Detector (600 LP; 610/20)\n\n\nBV650 Detector (635 LP; 670/30)\n\n\nBV711 Detector (690 LP; 710/50)\n\n\nBV786 Detector (750 LP; 780/60)\n\nLaser System UV-G4 355-20 W/BE SORP\n\n\n\nUV Detector Decagon w/o SSC with specific detectors:\nBUV396 Detector (378/29)\n\n\nBUV496 Detector (450LP: 515/30)\n\n\nBUV563 Detector (550LP: 586/15)\n\n\nBUV661 Detector (635 LP: 670/30\n\n\nBUV737 Detector (690 LP; 740/35)\n\n\nBUV805 Detector (770 LP; 820/60)\n\nLaser Coherent OBIS 561-100 LS SORP\n\n\nDetector Decagon w/o SSC with specific detectors:\nPE with 561 Detector (570 LP: 586/15)\n\n\nPE CF594 Detector (600 LP: 610/20)\n\n\nPE Cy5 Detector (650 LP: 670/30)\n\n\nPE Cy7 Detector (750 LP: 780/60)\n\nFACSflow Supply System\n\n\nX-Optic 450/50 (410 LP; 450/50)\n\n\nX-Optic 515/30 (450 LP: 515/30)\n\n\nCoherent connection with integration kit\n\n\nFACS Diva software\n\n\n\n\n\n\nTasks and deliverables include the following:\n-Preventive maintenance visits by qualified personnel (two visits in 12-month period)\n-Preventive maintenance kits (two kits in 12-month period)\n-Unlimited technical support by phone\n-Unlimited on-site visits by qualified personnel (Monday-Friday, excluding holidays) if problems are not resolved by phone support\n-Any parts, labor, or repairs needed as determined by the qualified personnel to ensure the flow cytometer is operating at peak performance\n\n\nReporting requirement:  The results of the preventive maintenance visits and all on-site visits will be provided by e-mail to the designated VA point-of-contact.  Plans for on-site visits will be communicated with the point-of-contact.  Verbal communication will also be used to provide updates regarding any issues with the flow cytometer and should include the plan of action to repair the flow cytometer, any parts that need to be ordered, and the anticipated time by which the repairs should be complete.  \n\n\n\nThis notice of intent is not a request for competitive proposals. Any responsible sources who wish to identify their interest and capability to provide this equipment or equipment that is compatible must notify this Contract Specialist at mae.mcgarry@va.gov NLT Thursday, April 24th, 2025 by 11:59 AM EST. Telephone responses will not be accepted. Upon receipt of the interested parties' notification, the Contract Specialist will determine whether to conduct a competitive procurement or proceed with sole source negotiations.","origin":"detail"},"contacts":[{"name":"Mae McGarry","role":"primary","email":"mae.mcgarry@va.gov","phone":"Calls will not be accepted.","title":"Contract Specialist"}],"place_of_performance":null,"office_address":{"zip":"15212","city":"PITTSBURGH","state":"PA","country":"USA"},"naics_codes":["811310"],"award":{"awardee":{}},"attachments":[{"resource_id":"637cc691bc22459cb78635f50c1ccf24","name":"36C24E25Q0042_1.docx","kind":"file","mime_type":".docx","size_bytes":19391,"posted_at":"2025-04-17T18:13:02.242Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/637cc691bc22459cb78635f50c1ccf24/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C24E25P0033_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C24E25P0033_3600_-NONE-_-NONE-/","piid":"36C24E25P0033","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"MM5ZHL8SRFY5","recipient_name":"BECTON, DICKINSON AND COMPANY","recipient_uei":"MM5ZHL8SRFY5","recipient_cage":"0GKS0","recipient_city":"SAN JOSE","recipient_state":"CA","sub_name":"Department of Veterans Affairs","office_name":"RPO EAST (36C24E)","office_key":"o-36C24E","first_action_date":"2025-07-01","last_action_date":"2025-10-23","actions":2,"obligated":"40825.20","current_total_value":"40825.20","potential_total_value":"40825.20","naics":"811310","psc":"J065","extent_competed":"COMPETED UNDER SAP","set_aside":"NO SET ASIDE USED.","offers_received":1,"description":"SERVICES","method":"solicitation","confidence":"high","evidence":["solicitation number 36C24E25Q0042 equals the FPDS solicitation identifier","same awarding office 36C24E"],"opportunity_key":null,"opportunity_title":null}],"related":[],"similar_open":[{"key":"W50S6Y27RA002","latest_notice_id":"87cba3e75e354d12990453adb59fe26e","title":"Halon Bottle Inspection","solicitation_number":"W50S6Y27RA002","notice_type":"o","first_type":"r","first_posted":"2026-11-07","last_posted":"2026-11-20","notices":6,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W50S6Y","office_name":"W7M2 USPFO ACTIVITY FLANG 125","naics":"811310","psc":"J042","set_aside":"SBA","state":"FL","county":"12031","county_name":"Duval County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"N3225327Q0011","latest_notice_id":"e4f2bdc21bab431d8dddd03dc4c01ccf","title":"Dry Dock Flow Meter Service","solicitation_number":"N32253-27-Q-0011","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-24","notices":2,"due_at":"2026-11-27T18:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N32253","office_name":"PEARL HARBOR NAVAL SHIPYARD IMF","naics":"811310","psc":"J049","set_aside":null,"state":"HI","county":"15003","county_name":"Honolulu County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"W912PL27QA001","latest_notice_id":"55fd39a8c25743939ed3ffe95d292b4e","title":"Material Handling Equipment (MHE) and Industrial Equipment (IE) Maintenance and Repair Services","solicitation_number":"W912PL27QA001","notice_type":"k","first_type":"k","first_posted":"2026-10-23","last_posted":"2026-11-20","notices":3,"due_at":"2026-11-27T22:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912PL","office_name":"W075 ENDIST LOS ANGELES","naics":"811310","psc":"J039","set_aside":"SBA","state":"CA","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_street","state_evidence":"SOUTH EL MONTE, CA 91733","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":58,"indexable":false}